Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

e_Buah Biblioteca Digital Universidad de Alcalá
Publication Contribución de congreso (ConferenceOutput)

Polarisation pulling in Brillouin optical time-domain analysers

  • Soto Hernández, Marcelo Alfonso
  • López Gil, Alexia Inés
  • González Herráez, Miguel|||0000-0003-2555-2971
  • Thévenaz, Luc
The impact of Brillouin scattering on the polarisation of pump and probe in a Brillouin optical-time domain analyser is investigated. Experimental results indicate that the Brillouin interaction integrated along the entire sensing fibre produces a polarisation pulling force that changes the pump polarisation. Although this force can be compensated to first order by dual-sideband probes, the Brillouin gain/loss experienced by probe bands induce a net pulling that leads to uncompensated polarisation fading and reduced signal-to-noise ratio. While the use of two simultaneous orthogonally-polarised probes alleviates fading issues, spectral distortions originate from the coupling between Brillouin gain and polarisation pulling., European Commission, Swiss Commission for Technology and Innovation, Israel Science Foundation
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Analysis and reduction of large errors in Rayleigh-based distributed sensor

  • Li, Zhang
  • Pereira da Costa, Luis Duarte|||0000-0001-5254-0605
  • Zhisheng, Yang
  • Soto Hernández, Marcelo Alfonso
  • González Herráez, Miguel|||0000-0003-2555-2971
  • Thévenaz, Luc
Commonly, the frequency shift of back-reflection spectra is the key parameter to measure quantitatively local temperature or strain changes in frequency-scanned Rayleigh-based distributed fiber sensors. Cross correlation is the most common method to estimate the frequency shift; however, large errors may take place, particularly when the frequency shift introduced by the temperature or strain change applied to the fiber is beyond the spectral width of the main correlation peak. This fact substantially limits the reliability of the system, and therefore requires careful analysis and possible solutions. In this paper, an analytical model is proposed to thoroughly describe the probability of large errors. This model shows that the cross correlation intrinsically and inevitably leads to large errors when the sampled signal distribution is finite, even under perfect signal-to-noise ratio. As an alternative solution to overcome such a problem, least mean squares is employed to estimate the frequency shift. In addition to reducing the probability of large errors, the proposed method only requires to measure a narrow spectrum, significantly reducing the measurement time compared to state-of-the-art implementations. Both the model and the solution are experimentally verified using a frequency-scanned phase-sensitive optical time-domain reflectometry system, achieving a spatial resolution of 5 cm, with a sensing range of 860 m and an acquisition time below 15 s, over a measurable temperature range of more than 100 K with a repeatability of 20 mK, corresponding to a temperature dynamic range of 5000 resolved points., European Commission, Swiss Commission for Technology and Innovation