Skip to main content

PREDICCION DE EMISIONES Y EXPOSICION A PARTICULAS MICRO Y NANOMETRICAS EN AMBIENTES INDUSTRIALES. DESARROLLO DE MODELOS DE PREDICCION.

CGL2015-66777-C2-2-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2015
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Dirección General de Investigación Científica y Técnica
Beneficiary centre UNIVERSITAT JAUME I DE CASTELLO

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Testing the performance of one and two box models as tools for risk assessment of particle exposure during packing of inorganic fertilizer

  • Ribalta, Carla
  • Koivisto, Antti J.
  • López-Lilao, Ana
  • Estupiñá, Sara
  • Minguillón, María Cruz
  • Monfort, Eliseo
  • Viana, Mar
Modelling of particle exposure is a useful tool for preliminary exposure assessment in workplaces with low and high exposure concentrations. However, actual exposure measurements are needed to assess models reliability. Worker exposure was monitored during packing of an inorganic granulate fertilizer at industrial scale using small and big bags. Particle concentrations were modelled with one and two box models, where the emission source was estimated with the fertilizer's dustiness index. The exposure levels were used to calculate inhaled dose rates and test accuracy of the exposure modellings. The particle number concentrations were measured from worker area by using a mobility and optical particle sizer which were used to calculate surface area and mass concentrations. The concentrations in the worker area during pre-activity ranged 63,797–81,073 cm−3, 4.6 × 106 to 7.5 × 106 μm2 cm−3, and 354 to 634 μg m−3 (respirable mass fraction) and during packing 50,300 to 85,949 cm−3, 4.3 × 106 to 7.6 × 106 μm2 cm−3, and 279 to 668 μg m−3 (respirable mass fraction). Thus, the packing process did not significantly increase the exposure levels. Chemical exposure was also under control based on REACH standards. The particle surface area deposition rate in respiratory tract was up to 7.6 × 106 μm2 min−1 during packing, with 52%–61% of deposition occurring in the alveolar region. Ratios of the modelled and measured concentrations were 0.98 ± 0.19 and 0.84 ± 0.12 for small and big bags, respectively, when using the one box model, and 0.88 ± 0.25 and 0.82 ± 0.12, when using the two box model. The modelling precision improved for both models when outdoor particle concentrations were included. This study shows that exposure concentrations in a low emission industrial scenario, e.g. during packing of a fertilizer, can be predicted with a reasonable accuracy by using the concept of dustiness and mass balance models., This research was founded by the Spanish MINECO (CGL2015-66777-C2-1-R, 2-R), Generalitat de Catalunya AGAUR 2017 SGR41, the Spanish Ministry of the Environment (13CAES006), FEDER (European Regional Development Fund) “Una manera de hacer Europa” and H2020 project caLIBRAte (Work Package 7). M.C. Minguillón acknowledges the Ramón y Cajal Fellowship awarded by the Spanish Ministry of Economy, Industry and Competitiveness. The authors also acknowledge the company in which the measurements were carried out for their support. The authors declare no conflict of interest relating to the material presented in this article., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

On the Relationship between Exposure to Particles and Dustiness during Handling of Powders in Industrial Settings

  • Ribalta, Carla
  • Viana, Mar
  • López-Lilao, Ana
  • Estupiñá, Sara
  • Minguillón, María Cruz
  • Mendoza, Joan
  • Díaz, Jordi
  • Dahmann, Dirk
  • Monfort, Eliseo
Exposure to ceramic powders, which is frequent during handling operations, is known to cause adverse health effects. Finding proxy parameters to quantify exposure is useful for efficient and timely exposure assessments. Worker exposure during handling of five materials [a silica sand (SI1), three quartzes (Q1, Q2, and Q3), and a kaolin (K1)] with different particle shape (prismatic and platy) and sizes (3.4-120 μm) was assessed. Materials handling was simulated using a dry pendular mill under two different energy settings (low and high). Three repetitions of two kilos of material were carried out per material and energy conditions with a flow rate of 8-11 kg h -1 . The performance of the dustiness index as a predictor of worker exposure was evaluated correlating material's dustiness indexes (with rotating drum and continuous drop) with exposure concentrations. Significant impacts on worker exposure in terms of inhalable and respirable mass fractions were detected for all materials. Mean inhalable mass concentrations during background were always lower than 40 μg m -3 whereas during material handling under high energy settings mean concentrations were 187, 373, 243, 156, and 430 μg m -3 for SI1, Q1, Q2, Q3, and K1, respectively. Impacts were not significant with regard to particle number concentration: background particle number concentrations ranged between 10 620 and 46 421 cm -3 while during handling under high energy settings they were 20 880 - 40 498 cm -3 . Mean lung deposited surface area during background ranged between 27 and 101 μm 2 cm -3 whereas it ranged between 22 and 42 μm 2 cm -3 during materials handling. TEM images evidenced the presence of nanoparticles (≤100 nm) in the form of aggregates (300 nm-1 μm) in the worker area, and a slight reduction on mean particle size during handling was detected. Dustiness and exposure concentrations showed a high degree of correlation (R 2 = 0.77-0.97) for the materials and operating conditions assessed, suggesting that dustiness could be considered a relevant predictor for workplace exposure. Nevertheless, the relationship between dustiness and exposure is complex and should be assessed for each process, taking into account not only material behaviour but also energy settings and workplace characteristics. © The Author(s) 2018., This research was funded by the Spanish MINECO (CGL2015-66777-C2-1-R, 2-R), Generalitat de Catalunya AGAUR 2014 SGR33, the Spanish Ministry of the Environment (13CAES006) and FEDER (European Regional Development Fund) “Una manera de hacer Europa”. M.C. Minguillón acknowledges the Ramón y Cajal Fellowship awarded by the Spanish Ministry of Economy, Industry and Competitiveness. The authors also acknowledge the company MOLARIS for their support with technical information on the mill used. The authors declare no conflict of interest relating to the material presented in this article., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Modeling of High Nanoparticle Exposure in an Indoor Industrial Scenario with a One-Box Model

  • Ribalta, Carla
  • Koivisto, Antti J.
  • Salmatonidis, Apostolos
  • López-Lilao, Ana
  • Monfort, Eliseo
  • Viana, Mar
Mass balance models have proved to be effective tools for exposure prediction in occupational settings. However, they are still not extensively tested in real-world scenarios, or for particle number concentrations. An industrial scenario characterized by high emissions of unintentionally-generated nanoparticles (NP) was selected to assess the performance of a one-box model. Worker exposure to NPs due to thermal spraying was monitored, and two methods were used to calculate emission rates: the convolution theorem, and the cyclic steady state equation. Monitored concentrations ranged between 4.2 × 104–2.5 × 105 cm−3. Estimated emission rates were comparable with both methods: 1.4 × 1011–1.2 × 1013 min−1 (convolution) and 1.3 × 1012–1.4 × 1013 min−1 (cyclic steady state). Modeled concentrations were 1.4-6 × 104 cm−3 (convolution) and 1.7–7.1 × 104 cm−3 (cyclic steady state). Results indicated a clear underestimation of measured particle concentrations, with ratios modeled/measured between 0.2–0.7. While both model parametrizations provided similar results on average, using convolution emission rates improved performance on a case-by-case basis. Thus, using cyclic steady state emission rates would be advisable for preliminary risk assessment, while for more precise results, the convolution theorem would be a better option. Results show that one-box models may be useful tools for preliminary risk assessment in occupational settings when room air is well mixed., This research was funded by the Spanish MINECO (CGL2015-66777-C2–1-R, 2-R), and through project PCIN-2015–173-C02-01, under the frame of SIINN, the ERA-NET for a Safe Implementation of Innovative Nanoscience and Nanotechnology, by SIINN-ERANET project CERASAFE (id.:16). Additional support was provided by Generalitat de Catalunya AGAUR 2017 SGR41, the Spanish Ministry of the Environment (13CAES006), FEDER (European Regional Development Fund) “Una manera de hacer Europa”., Peer reviewed