Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Calibration of a trinocular system formed with wide angle lens cameras

  • Ricolfe Viala, Carlos|||0000-0002-2980-4569
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Valera Fernández, Ángel|||0000-0001-6843-6394
To obtain 3D information of large areas, wide angle lens cameras are used to reduce the number of cameras as much as possible. However, since images are high distorted, errors in point correspondences increase and 3D information could be erroneous. To increase the number of data from images and to improve the 3D information, trinocular sensors are used. In this paper a calibration method for a trinocular sensor formed with wide angle lens cameras is proposed. First pixels locations in the images are corrected using a set of constraints which define the image formation in a trinocular system. When pixels location are corrected, lens distortion and trifocal tensor is computed., This work was partially funded by the Universidad Politecnica de Valencia research funds (PAID 2010-2431 and PAID 10017), Generalitat Valenciana (GV/2011/057) and by Spanish government and the European Community under the project DPI2010-20814-C02-02 (FEDER-CICYT) and DPI2010-20286 (CICYT).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Camera calibration under optimal conditions

  • Ricolfe Viala, Carlos|||0000-0002-2980-4569
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
Different methods based on photogrammetry or self-calibration exist to calibrate intrinsic and extrinsic camera parameters and also for data pre- and post-processing. From a practical viewpoint, it is quite difficult to decide which calibration method gives accurate results and even whether any data processing is necessary. This paper proposes a set of optimal conditions to resolve the calibration process accurately. The calibration method uses several images of a 2D pattern. Optimal conditions define the number of points and the number of images to resolve the calibration accurately, as well as positions and orientations from where images should be taken., This work was partially funded by the Universidad Politecnica de Valencia research funds (PAID 2010-2431 and PAID 10017), Generalitat Valenciana (GV/2011/057) and by Spanish government and the European Community under the project DPI2010-20814-C02-02 (FEDER-CICYT) and DPI2010-20286 (CICYT).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Efficient lens distortion correction for decoupling in calibration of wide angle lens cameras

  • Ricolfe Viala, Carlos|||0000-0002-2980-4569
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Valera Fernández, Ángel|||0000-0001-6843-6394
In photogrammetry applications, camera parameters must be as accurate as possible to avoid deviations in measurements from images. Errors increase if wide angle lens cameras are used. Moreover, the coupling between intrinsic and extrinsic camera parameters and the lens distortion model influences the result of the calibration process notably. This paper proposes a method for calibrating wide angle lens cameras, which takes into account the existing hard coupling. The proposed method obtains stable results, which do not depend on how the image lens distortion is corrected., This work was supported in part by the Universidad Politecnica de Valencia research funds (PAID 2010-2431 and PAID 10017), the Generalitat Valenciana (GV/2011/057) and the Spanish government and the European Community under Project DPI2010-20814-C02-02 (FEDER-CICYT) and Project DPI2010-20286 (CICYT). The associate editor coordinating the review of this paper and approving it for publication was Dr. Subhas C. Mukhopadhyay.