RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Impact of surrounding tissue-type and peri-electrode gap in stereoelectroencephalography guided (SEEG) radiofrequency thermocoagulation (RF-TC): a computational study

  • Collavini, Santiago
  • Fernández-Corazza, Mariano
  • Oddo, Silvia
  • Irastorza, Ramiro Miguel
  • Pérez, Juan J|||0000-0001-8486-8699
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Purpose: To use computational modeling to provide a complete and logical description of the electrical and thermal behavior during stereoelectroencephalography-guided (SEEG) radiofrequency thermocoagulation (RF-TC). Methods: A coupled electrical-thermal model was used to obtain the temperature distributions in the tissue during RF-TC. The computer model was first validated by an ex vivo model based on liver fragments and later used to study the impact of three different factors on the coagulation zone size: 1) the difference in the tissue surrounding the electrode (gray/white matter), 2) the presence of a peri-electrode gap occupied by cerebrospinal fluid (CSF), and 3) the energy setting used (power-duration). Results: The model built for the experimental validation was able to predict both the evolution of impedance and the short diameter of the coagulation zone (error < 0.01mm) reasonably well but overestimated the long diameter by 2¿3mm. After adapting the model to clinical conditions, the simulation showed that: 1) Impedance roll-off limited the coagulation size but involved overheating (around 100°C); 2) The type of tissue around the contacts (gray vs. white matter) had a moderate impact on the coagulation size (maximum difference 0.84mm), and 3) the peri-electrode gap considerably altered the temperature distributions, avoided overheating, although the diameter of the coagulation zone was not very different from the no-gap case (<0.2mm). Conclusions: This study showed that computer modeling, especially subject- and scenario-specific modeling, can be used to estimate in advance the electrical and thermal performance of the RF-TC in brain tissue., Spanish Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fondo Europeo de Desarrollo Regional (Grant PID2022-136273OB-C31 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE), Argentinean National Agency for the Promotion of Science and Technology ANPCyT (PICT 2019-0701, PICT 2020-00457), CONICET Argentina (PIP 11220200101515CO), and Universidad Tecnológica Nacional (PID Grant No. MAECLP0009851TC).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Body Size Modulates the Impact of the Dispersive Patch Position During Radiofrequency Cardiac Ablation.

  • Irastorza, Ramiro Miguel
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] (1) Background: In the context of cardiac radiofrequency (RF) ablation, it has been proposed that positioning the dispersive patch (DP) concordantly with the orientation of the ablation electrode may enhance lesion size. The objective of this study is to investigate how individual body size may modulate the extent of this effect. (2) Methods: Three computational models representing different body sizes were developed. An irrigated catheter ablation was simulated by delivering a 30 W pulse for 30 s to the endocardial surface of the anterior wall. Lesion sizes were then compared between two configurations of the dispersive patch (DP): an anterior (concordant) position and a posterior (discordant) position. (3) Results: Lesion size was consistently and significantly greater with concordant DP positioning compared to discordant positioning. Moreover, the magnitude of this difference decreased significantly with increasing body size, ranging from 0.65 +/- 0.08 mm in the 35 kg swine model to 0.51 +/- 0.06 mm in the human model. (4) Conclusions: Body size has a modest influence on the effect of dispersive patch positioning on RF lesion size. The potential advantage of a concordant DP configuration may be more significant in individuals with smaller body volume., This work was also supported by grants: PICT 2020-00457 (Agencia Nacional de Promocion de la Investigacion, el Desarrollo Tecnologico y la Innovacion, Argentina); PID UTN: MAECLP0009851TC (Universidad Tecnologica Nacional); PID2022-136273OB-C31 (Spanish Ministerio de Ciencia, Innovacion y Universidades, Agencia Estatal de Investigacion, Fondo Europeo de Desarrollo Regional (MICIU/AEI/10.13039/501100011033/ERDF/EU)).