Skip to main content

NUEVAS METODOLOGIAS EN EL ANALISIS DEL CONFORT TERMICO Y LA EFICIENCIA ENERGETICA EN EDIFICIOS CON MODELOS 5D

PID2019-108271RB-C33

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2019
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental Data and Simulations of Performance and Thermal Comfort in a Typical Mediterranean House

  • Pérez-Andreu, Víctor
  • Aparicio Fernandez, Carolina Sabina|||0000-0003-0197-9452
  • Vivancos, José-Luis|||0000-0002-8524-5466
  • Cárcel-Carrasco, Javier|||0000-0003-2776-533X
[EN] The number of buildings renovated following the introduction of European energy-efficiency policy represents a small number of buildings in Spain. So, the main Spanish building stock needs an urgent energy renovation. Using passive strategies is essential, and thermal characterization and predictive tests of the energy-efficiency improvements achieving acceptable levels of comfort for their users are urgently necessary. This study analyzes the energy performance and thermal comfort of the users in a typical Mediterranean dwelling house. A transient simulation has been used to acquire the scope of Spanish standards for its energy rehabilitation, taking into account standard comfort conditions. The work is based on thermal monitoring of the building and a numerical validated model developed in TRNSYS. Energy demands for different models have been calculated considering different passive constructive measures combined with real wind site conditions and the behavior of users related to natural ventilation. This methodology has given us the necessary information to decide the best solution in relation to energy demand and facility of implementation. The thermal comfort for different models is not directly related to energy demand and has allowed checking when and where the measures need to be done., This research was funded by the Ministry of Science and Innovation (PID2019-108271RB-C33).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Efecto de las Condiciones Higrotérmicas en Sistema Estructural de Forjado con Viguetas de Madera y Muro de Mampostería, Analysis of the effects of the hygrothermal conditions in a structural system with wood joist floor slab and masonry wall

  • Torner-Feltrer, María Eugenia Milagro|||0000-0002-8296-0632
  • Cañada-Soriano, Mar|||0000-0002-9435-2132
  • Vivancos, José-Luis|||0000-0002-8524-5466
  • Aparicio Fernandez, Carolina Sabina|||0000-0003-0197-9452
  • Royo, Rafael|||0000-0003-3488-0221
[ES] Para la rehabilitación energética de los edificios históricos públicos diversas han sido las medidas impulsadas por Europa para que puedan llevarse a cabo con el fin de reducir el consumo energético. La instalación de aislamientos interiores en edificios donde no se puede llevar a cabo también en muros exteriores por su valor patrimonial y su tipología constructiva hacen que se produzcan una serie de condicionantes higrotérmicos que puedan alterar los elementos estructurales construidos llegando a alcanzar un alto contenido de humedad. El daño que este hecho puede producir en edificios con tipologías de sistema estructural de forjado de viguetas de madera, puede tener una gran repercusión tanto en los elementos estructurales como en los encuentros de estos con los muros exteriores. Las mediciones de las monitorizaciones de las condiciones higrotérmicas junto con el estudio de las condiciones climáticas pueden darnos un modelo más empírico del por qué de la situación en las que se encuentran los elementos y cómo poder solucionar los distintos encuentros para un mejor aislamiento., [EN] For the energetic rehabilitation of historic public buildings, several measures have been promoted by Europe to reduce energy consumption. The installation of interior insulation in buildings where it cannot be carried out also in exterior walls because of their heritage value and their constructive typology cause a series of hygrothermal conditions that can alter the structural elements built reaching a high moisture content. The damage that this fact can produce in buildings with structural system typologies of wood joist floor slabs, can have a great repercussion in the structural elements as well as in the encounters of these with the exterior walls. The measurements of the monitoring of the hygrothermal conditions together with the study of the climatic conditions can give us a more empirical model of the reason for the situation in which the elements are found and how to solve the different encounters for better insulation., Esta publicación es parte del proyecto de I+D+i PID2019-108271RB-C33, financiado por MCIN/ AEI/10.13039/501100011033
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Automatic generation of as-is BEM models of buildings

  • Adan, A.
  • Vilar-Abad, Alejandro
  • Ramón-Constantí, Amanda|||0000-0001-7084-8275
  • Vivancos, José-Luis|||0000-0002-8524-5466
  • Aparicio Fernandez, Carolina Sabina|||0000-0003-0197-9452
[EN] This paper shows a method with which to create a proprietary as-is 3D semantic thermal model of a building and transform it into standard BEM formats. Geometric and relational information regarding the essential structural elements of the building (i.e., zone, ceiling, floor, wall, door, etc.) is, together with their corresponding as-is temperatures, first extracted from thermal points clouds of the scene and then adapted to the standard geometric BEM requirements. Non-geometric properties concerning definitions and properties of envelopes, windows and doors are also defined as essential information. After all this information has been collected, a BEM file is eventually generated in order to be used in energy simulation software. One of the specific features of this work is the generation of as-is BIM formats of the interior of a building that are later adapted for energy simulation applications in EnergyPlus and TRNSYS software. An ASCII file containing the temperatures of the main structural elements of the building is also created. The method has been tested on real thermal point clouds of the ground floor of a building, yielding promising results., This research was funded by the European Regional Development Fund (SBPLY/19/180501/) and the Ministry of Science and In-novation (PID2019-108271RB-C31, PROYECTO/AEI/10.13039/501100011033 and PID2019-108271RB-C33)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Analysis of the energy performance strategies in a historical building used as a music school

  • Aparicio Fernandez, Carolina Sabina|||0000-0003-0197-9452
  • Torner-Feltrer, María Eugenia Milagro|||0000-0002-8296-0632
  • Cañada-Soriano, Mar|||0000-0002-9435-2132
  • Vivancos, José-Luis|||0000-0002-8524-5466
[EN] Energy consumption in public education buildings depends on use and occupancy. To improve energy performance, energy audits are essential to identify specific solutions for each building. In this study, we conducted an energy audit of a historical building used as a public education centre. We collected gas and electricity bills and recorded indoor temperatures for over a year to determine heating and cooling set points and the schedules. Our analysis showed that 47.42% of the electricity bills were unused. To reduce energy demand and improve thermal comfort, we both developed and validated a Building Energy Modelling (BEM) approach using TRNSYS18 and weather data during year 2021. The BEM model allowed us to propose efficient measures to meet the Standard Passive requirements. Our results demonstrate the effectiveness of energy audits and BEM modelling in reducing energy consumption in public education buildings., This research was funded by the Ministry of Science and Innovation, Spain PID2019-108271RB-C33). The study could not have taken place without the assistance of the personnel of professional conservatory of artistic education (Carcaixent). We also thank to the Spanish Meteorological Agency (© AEMET) for providing us with weather data.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Proposing 3D Thermal Technology for Heritage Building Energy Monitoring

  • Adan, Antonio
  • Pérez, Víctor
  • Prieto, Samuel A.
  • Vivancos, José-Luis|||0000-0002-8524-5466
  • Aparicio Fernandez, Carolina Sabina|||0000-0003-0197-9452
[EN] The energy monitoring of heritage buildings has, to date, been governed by methodologies and standards that have been defined in terms of sensors that record scalar magnitudes and that are placed in specific positions in the scene, thus recording only some of the values sampled in that space. In this paper, however, we present an alternative to the aforementioned technologies in the form of new sensors based on 3D computer vision that are able to record dense thermal information in a three-dimensional space. These thermal computer vision-based technologies (3D-TCV) entail a revision and updating of the current building energy monitoring methodologies. This paper provides a detailed definition of the most significant aspects of this new extended methodology and presents a case study showing the potential of 3D-TCV techniques and how they may complement current techniques. The results obtained lead us to believe that 3D computer vision can provide the field of building monitoring with a decisive boost, particularly in the case of heritage buildings, This research was funded by the European Regional Development Fund (SBPLY/19/180501/000094 project) and the Ministry of Science and Innovation (PID2019-108271RB-C31 and PID2019108271RB-C33).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Thermal Characterization of Buildings with as-is Thermal-Building Information Modelling

  • Pérez-Andreu, Víctor
  • Adán Oliver, Antonio
  • Aparicio Fernandez, Carolina Sabina|||0000-0003-0197-9452
  • Vivancos, José-Luis|||0000-0002-8524-5466
[EN] Developing methodologies to accurately characterise the energy conditions of existing building stock is a fundamental aspect of energy consumption reduction strategies. To that end, a case study using a thermal information modelling method for existing buildings (as-is T-BIM) is reported. This proposed new method is based on the automatic processing of 3D thermal clouds of interior zones of a building that generates a semantic proprietary model that contains time series of surface temperatures assigned to its surface elements. The proprietary as-is T-BIM automatically generates an as-is BEM model with gbXML standards for energy simulation. This is a multi-zone energy model of the building. In addition, the surface temperature data series of the as-is T-BIM model elements permit the calculation of their thermal transmittances, increasing the calibration options of the obtained as-is BEM model. To test the as-is TBIM method, a case study compares the as-is BEM model obtained by as-is T-BIM methods with the one obtained by standard methods for the same building. The results demonstrate differences in geometry, transmittance, and infiltration values, as well as insignificant differences in annual air conditioning energy consumption or the comfort parameters tested. This seems to indicate shorter modelling times and greater accuracy of the as-is T-BIM model., This research was funded by the European Regional Development Fund (SBPLY/19/180501/000094 project) and the Ministry of Science and Innovation (PID2019-108271RB-C31 and PID2019-108271RB-C33).