Insulin dosage optimization based on prediction of postprandial glucose excursions under uncertain parameters and food intake

  • García Jaramillo, Maira Alejandra
  • Calm, R.
  • Tarin, C.
  • Vehi, J.
  • Bondía Company, Jorge|||0000-0001-7286-3719
Considering the difficulty in selecting correct insulin doses and the problem of hyper- and hypoglycemia episodes in type 1 diabetes, dosage-aid systems are very useful for these patients. A model-based approach to this problem must unavoidably consider uncertainty sources such as large intra-patient variability and food intake. In the present study, postprandial glucose is predicted considering this uncertain information using modal interval analysis. This approach calculates a safer prediction of possible hyper- and hypoglycemia episodes induced by insulin therapy for an individual patient's parameters and integrates this information into a dosage-aid system. Predictions of a patient's postprandial glucose at 5-h intervals are used to predict the risk for a given therapy. Then the insulin dose and injection-to-meal time with the lowest risk are calculated. The method has been validated for three different scenarios corresponding to preprandial glucose values of 100, 180 and 250 mg/dl., This work was partially supported by the Spanish Ministry of Science and Innovation and the European Union through grant DPI-2007-66728 and by the Autonomous Government of Catalonia through SGR00523.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Improving the computational effort of set-inversion-based prandial insulin delivery for its integration in insulin pumps

  • León-Vargas, Fabián
  • Calm, Remei
  • Vehí, Josep
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] Objective: Set-inversion-based prandial insulin delivery is a new model-based bolus advisor for postprandial glucose control in type 1 diabetes mellitus (T1DM). It automatically coordinates the values of basal-bolus insulin to be infused during the postprandial period so as to achieve some predefined control objectives. However, the method requires an excessive computation time to compute the solution set of feasible insulin profiles, which impedes its integration into an insulin pump. In this work, a new algorithm is presented, which reduces computation time significantly and enables the integration of this new bolus advisor into current processing features of smart insulin pumps. Methods: A new strategy was implemented that focused on finding the combined basal-bolus solution of interest rather than an extensive search of the feasible set of solutions. Analysis of interval simulations, inclusion of physiological assumptions, and search domain contractions were used. Data from six real patients with T1DM were used to compare the performance between the optimized and the conventional computations. Results: In all cases, the optimized version yielded the basal-bolus combination recommended by the conventional method and in only 0.032% of the computation time. Simulations show that the mean number of iterations for the optimized computation requires approximately 3.59 s at 20 MHz processing power, in line with current features of smart pumps. Conclusions: A computationally efficient method for basal-bolus coordination in postprandial glucose control has been presented and tested. The results indicate that an embedded algorithm within smart insulin pumps is now feasible. Nonetheless, we acknowledge that a clinical trial will be needed in order to justify this claim., This work was partially supported by the Spanish Ministry of Science and Innovation through Grant DPI-2010-20764-C02 and by the Autonomous Government of Catalonia through Grant SGR 523. Fabian León-Vargas acknowledges the FI grants of Generalitat de Catalunya.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Comparison of interval and Monte Carlo simulation for the prediction of postprandial glucose under uncertainty in type 1 diabetes mellitus

  • Calm, R.
  • García-Jaramillo, M.
  • Sainz, M.A.
  • Vehí, J.
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] In this paper, the problem of tackling uncertainty in the prediction of postprandial blood glucose is analyzed. Two simulation approaches, Monte Carlo and interval models, are studied and compared. Interval simulation is carried out using modal interval analysis. Simulation of a glucoregulatory model with uncertainty in insulin sensitivities, glucose absorption and food intake is carried out using both methods. Interval simulation is superior in predicting all severe and mild hyper- and hypoglycemia episodes. Furthermore, much less computational time is required for interval simulation than for Monte Carlo simulation, This work was partially supported by the Spanish Ministry of Science and Innovation and the European Union through Grant DPI-2007-66728 and by the Autonomous Government of Catalonia through SGR00523.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Prediction of postprandial blood glucose under uncertainty and intra-patient variability in type 1 diabetes: a comparative study of three interval models,

  • García Jaramillo, Maira Alejandra
  • Calm, R.
  • Vehí, J.
  • Bondía Company, Jorge|||0000-0001-7286-3719
The behavior of three insulin action and glucose kinetics models was assessed for an insulin therapy regime in the presence of patient variability. For this purpose, postprandial glucose in patients with type 1 diabetes was predicted by considering intra- and inter-patient variability using modal interval analysis. Equations to achieve optimal prediction are presented for models 1, 2 and 3, which are of increasing complexity. The model parameters were adjusted to reflect the “same” patient in the presence of variability. The glucose response envelope for model 1, the simplest insulin–glucose model assessed, included the responses of the other two models when a good fit of the model parameters was achieved. Thus, under variability, simple glucose–insulin models may be sufficient to describe patient dynamics in most situations., This work was partially supported by the Spanish Ministry of Science and Innovation through Grant DPI-2010-20764-C02, and by the Autonomous Government of Catalonia through Grant SGR 523.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A simple robust method for estimating the glucose rate of appearance from mixed meals

  • Herrero, P.
  • Palerm, C.C.
  • Vehí, J.
  • Georgiou, P.
  • Oliver, N.
  • Toumazou, C.
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] Background: Estimating the rate of glucose appearance (Ra) after ingestion of a mixed meal may be highly valuable in diabetes management. The gold standard technique for estimating Ra is the use of a multitracer oral glucose protocol. However, this technique is complex and is usually not convenient for large studies. Alternatively, a simpler approach based on the glucose-insulin minimal model is available. The main drawback of this last approach is that it also requires a gastrointestinal model, something that may lead to identifiability problems. Methods: In this article, we present an alternative, easy-to-use method based on the glucose-insulin minimal model for estimation of Ra. This new technique avoids complex experimental protocols by only requiring data from a standard meal tolerance test. Unlike other model-based approaches, this new approach does not require a gastrointestinal model, which leads to a much simpler solution. Furthermore, this novel technique requires the identification of only one parameter of the minimal model because the rest of the model parameters are considered to have small variability. In order to account for such variability as well as to account for errors associated to measurements, interval analysis has been employed. Results: The current technique has been validated using data from a United States Food and Drug Administration-accepted type 1 diabetes simulator [root mean square error (RMSE) = 0.77] and successfully tested with two clinical data sets from the literature (RMSE = 0.69). Conclusions: The presented technique for the estimation of Ra showed excellent results when tested with simulated and actual clinical data. The simplicity of this new technique makes it suitable for large clinical research studies for the evaluation of the role of Ra in patients with impairments in glucose metabolism. In addition, this technique is being used to build a model library of mixed meals that could be incorporated into diabetic subject simulators in order to account for more realistic and varied meals., This work has been funded by the Wellcome Trust, the Spanish Ministry of Science and Innovation through grant DPI2010-20764-C02, the European Union through FEDER funds, and Generalitat de Catalunya under Grant 2009 SGR 523.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Detection of correct and incorrect measurements in real-time continuous glucose monitoring systems applying a postprocessing support vector machine

  • Leal, Yenny
  • GONZALEZ-ABRIL, LUIS
  • Lorencio, Carol
  • Vehí, Josep
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] Support vector machines (SVMs) are an attractive option for detecting correct and incorrect measurements in real-time continuous glucose monitoring systems (RTCGMSs), because their learning mechanism can introduce a postprocessing strategy for imbalanced datasets. The proposed SVM considers the geometric mean to obtain a more balanced performance between sensitivity and specificity. To test this approach, 23 critically ill patients receiving insulin therapy were monitored over 72 h using an RTCGMS, and a dataset of 537 samples, classified according to International Standards Organization (ISO) criteria (372 correct and 165 incorrect measurements), was obtained. The results obtained were promising for patients with septic shock or with sepsis, for which the proposed system can be considered as reliable. However, this approach cannot be considered suitable for patients without sepsis., This work was supported by the Spanish Ministry of Science and Innovation under Grant DPI-2010-20764-C02, and by the Autonomous Government of Catalonia under Grant 2009 SGR 523. In addition, this work was partially supported by the Spanish Ministry of Economy and Competitiveness through ARTEMISA (TIN2009-14378-C02-01), and by the Andalusia Regional Ministry of Economy, Innovation and Science through Simon (TIC-8052). Y. Leal was supported by BR Grants of the University of Girona.