Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Learning from the progressive collapse of buildings

  • Caredda, Giacomo|||0000-0002-6888-0409
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
  • Chryssanthopoulos, Marios
[EN] As building structures in different parts of the world become increasingly exposed to extreme events, there has been a notable research and professional effort to ensure the design of more robust buildings which are insensitive to local failures. At the same time, several works performed in the field of forensic structural engineering have contributed to advancing knowledge on causes and risk factors of structural failure. This includes the creation of several collapse databases, most of which focus mainly on the underlying hazards causing failure. While such databases have provided invaluable insights for preventing structural failures, they do not lend themselves well to the analysis of how failure propagates, which can be useful for improving the progressive collapse resistance of buildings. To this end, a novel database of building collapses is presented in this article which systematically collects information on the hazards, initial failures and their corresponding propagation mechanisms. In addition, key information related to the context and the consequences of collapse is also gathered. Based on the information compiled in the database, this article provides an in-depth analysis of the most commonly occurring initial failures and propagation mechanisms, with significant conclusions extracted from the study of past collapses. The application of different consequence models for estimating fatalities and reconstruction costs is also presented, leading to recommendations for improving such models and related data collection strategies., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union 's Horizon 2020 research and innovation programme (Grant agreement No. 101000396) . The authors are also very grateful to Ramon Hingorani and Peter Tanner for kindly sharing the database they employed to develop their consequence model.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Practical methodology for quantifying the structural robustness of RC building structures

  • Setiawan, Andri
  • Cetina-Berdugo, Diego Fernando|||0009-0008-2884-9694
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] Several structural robustness requirements have been included in building codes over the past two decades. These mainly include measures to prevent collapse after an initial component failure by ensuring a minimum level of continuity within the structural system so that loads supported by the failed component can be redis- tributed to the rest of the structural system. However, there is still a general lack of consensus on how to evaluate the effectiveness of these measures. The present study proposes a practical methodology to evaluate the struc- tural robustness of RC building structures by combining an efficient modelling strategy and suitable robustness indexes. The proposed computational modelling strategy for RC buildings accounts for relevant dynamic and nonlinear phenomena, including compressive arching, catenary action, and membrane effects. This strategy can be implemented at a reasonable computational expense in widely used commercial structural analysis software and has been validated by comparisons to selected experimental tests from the literature. The modelling strategy is then employed to compute four different robustness indexes proposed in the literature for three hypothetical building designs, allowing the indexes to be systematically compared. It was found that evaluating a system using multiple robustness indexes can provide a more holistic view of system performance compared to relying solely on a single index. Ultimately, the potential usefulness of the proposed methodology is demonstrated through two practical applications involving the estimation of component damage levels and the evaluation of different design and retrofitting solutions. Such a methodology can be useful for practising engineers to optimise the design of new buildings or to support decisions on the assessment and retrofitting of existing ones., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors would also like to express their gratitude for funding received under the postdoctoral programs of the Generalitat Valenciana/Fons Social Europeu [CIAPOS/2023/216] and for the Evolve project (ref. CIGE/2023/199).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Enhancing building robustness through a fuse-based segmentation framework

  • Caredda, Giacomo|||0000-0002-6888-0409
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
  • Chryssanthopoulos, Marios
[EN] The most widely used design approaches today for improving the robustness of buildings rely on improving continuity within the structural system to ensure that loads supported by failed components can be redistributed to the rest of the system. Although this is effective for small initial failures, it can increase the risk of disproportionate collapse after larger initial failures due to collapsing elements pulling down parts of the structure that would otherwise be unaffected. This form of continuity-enabled collapse propagation can be avoided by dividing a structure into different segments. However, completely separating parts of a building results in lower performance under operational conditions, against lateral loads, and after small initial failures. In fact, the advantages of both continuity and segmentation can be combined through a fuse-based segmentation approach in which predefined segment borders ensure connectivity after small initial failures but separate to isolate collapse after larger initial failures. To ensure that this approach is used effectively to improve the robustness of building structures, a design framework is proposed in this article to systematically consider relevant structural and geometric criteria in order to define suitable segmentation configurations for reinforced concrete and steel framed building structures. An application to a realistic case study is also presented to demonstrate the effectiveness of the proposed framework in enhancing structural robustness., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors also acknowledge funding received from the Generalitat Valenciana for the Evolve project (ref. CIGE/2023/199). Finally, the article has also benefitted from helpful conversations with Dr. Andri Setiawan (Universitat Polit`ecnica de Val`encia) on the proposed initial failure hierarchy verification.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Analysing the cost-effectiveness of improving building robustness through segmentation

  • Caredda, Giacomo|||0000-0002-6888-0409
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
  • Chryssanthopoulos, Marios
  • Stewart, Mark G.
[EN] Current design philosophies are not always able to guarantee the robustness of buildings, especially when extreme events cause initial failures for which alternative load paths cannot be effective. Fuse-based segmentation has the potential to address this shortcoming, by isolating collapse when its initiation is inevitable. However, no study has yet been performed to clarify under which conditions and in which contexts it can be a suitable solution to mitigate the risk of disproportionate building collapse. Most applicable frameworks for performing risk-based cost-benefit assessments cannot be directly applied to study fuse-based segmentation since they rely on overly simplified structural models that cannot represent collapse propagation phenomena. In this article, a scenario-based methodology is proposed for evaluating the cost-effectiveness of fuse-based segmentation. The proposed methodology was also applied to a case-study consisting of a six-storey reinforced concrete building, revealing that there are a wide range of contexts for which fuse-based segmentation can be cost-effective for this type of structure.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Breaking continuity to prevent catastrophic building collapse

  • Setiawan, Andri
  • Cetina-Berdugo, Diego Fernando
  • Gerbaudo, Maria Luz
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] It is increasingly difficult to predict all the hazards that buildings will face over their lifetime, highlighting the need to design robust structures that can tol- erate unforeseen damage. Typically, robustness is pursued by providing continuity within a structural system. While this strategy performs well in expected scenarios, it increases the risk of catastrophic collapse propagation when initial damage is large. Using high-fidelity simulations, we first identified and characterised the key mechanisms responsible for continuity-enabled collapse propagation in highly continuous building structures such as those made of cast-in-place reinforced concrete. Building on this understanding, we developed: 1) a design approach that employs bespoke force-regulating fuses to interrupt continuity when it becomes detrimental, and 2)anexperimental setup that allows system-level collapse propagation to be evaluated by testing only a representative part of a building. Overall, our work shows that con- tinuity can be selectively disengaged even in intrinsically continuous struc- tures and provides a cost-effective way of testing the next generation of solutions against unforeseen extreme events., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant agreement No. 101000396). N.M. acknowledges funding from the Generalitat Valenciana for the Evolve project (ref. CIGE/2023/199). A.S. acknowledges the funding provided by the La Caixa Foundation through the Postdoctoral Junior Leader Fellowships Retaining Call 2025 (Fellowship no. LCF/BQ/PR25/12110011).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Failure analysis after the progressive collapse of a precast building

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Setiawan, Andri
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Gerbaudo, Maria Luz|||0009-0003-2838-0316
  • Marin, Lorenzo|||0000-0002-7117-1291
  • Cetina-Berdugo, Diego Fernando|||0009-0008-2884-9694
  • Caredda, Giacomo|||0000-0002-6888-0409
  • Oliver-Cano, Marina
  • Adam, Jose M|||0000-0002-9205-8458
  • Sempértegui, Geovanny
[EN] As buildings have to face more frequent and intense extreme events due to a changing climate and rising geopolitical tensions, the need for more robust structures that are insensitive to initial failures is now arguably more important than ever before. In this context, this article presents an in-depth analysis of the damage and failures that occurred during the partial progressive collapse test of a purposely built 15×12 m precast building with two floors. The building was designed to ensure load redistribution after the failure of single columns and also to segment parts of the structure from a larger initial failure that inevitably triggers a collapse. The ability of the structure to arrest collapse propagation was tested experimentally successfully isolating the collapse to the initially affected area. Based on visual inspections supported by computational simulations, failure mechanisms occurring in the collapsed area and damages in the upright part of the structure are analysed in detail in this article. Mechanisms that enabled the separation of the building in two parts are also studied. The presented results lead to an improved understanding of failure mechanisms causing collapse propagation and provide insights on how such propagation can be arrested., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors would also like to express their gratitude for funding received under the postdoctoral Grant IJC2020-042642-I funded by MCIN/AEI/ 10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR", for funding received by the First Research Projects call (PAID-06-22) from the Vice-rectorate for Research of the Universitat Politecnica de Valencia, and for funding for open access charge by CRUE- Universitat Politecnica de Valencia. The research presented in this article would not have been possible without the assistance of the following colleagues from the ICITECH institute in preparing and executing the full-scale building test: Juan J. Moragues, Pedro A. Calderon, Daniel Tasquer, Ana Sanchez-Rodriguez, Eduardo J. Mezquida-Alcaraz and Ghobad Shahnazi. The authors are also grateful to the Levantina, Ingenieria y Construccion S.L. (LIC) company for providing human resources and access to their facilities for testing. Finally, the authors wish to thank Ayman Elfouly and Applied Science International-LLC for their support in performing simulations.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The effect of continuity reinforcement on the progression of collapse in reinforced concrete buildings

  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Adam, Jose M|||0000-0002-9205-8458
  • Orton, Sarah L.
[EN] Research performed on the progressive collapse of reinforced concrete buildings has led to the development of several design approaches relying on sufficient continuity reinforcement to provide alternative load paths that can prevent collapse after the failure of single columns. However, there are very few works examining the possible contribution that continuity reinforcement could have in pulling down parts of a structure that would otherwise be unaffected after large initial failures. This article presents the findings of a study based on validated simulations of a prototype building using the Applied Element Method (AEM). The results reveal that a large amount of continuity reinforcement can indeed contribute to more failure propagation after very large initial failures by transmitting more unbalanced forces to columns. It is also demonstrated that localised reductions in continuity reinforcement can prevent failure propagation after large initial failures. In addition, it is shown that this can be achieved while still allowing alternative load paths to develop after single-column failure as required by current codes and guidelines., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union ' s Horizon 2020 research and innovation programme (Grant agreement No. 101000396) . Funding for open access charge: CRUE-Universitat Politecnica de Valencia. The authors are also grateful to members of the ICITECH institute, and particularly Manuel Buitrago, for invaluable discussions on fuse -based segmentation.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Arresting failure propagation in buildings through collapse isolation

  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] Several catastrophic building collapses1¿5 occur because of the propagation of local-initial failures6,7. Current design methods attempt to completely prevent collapse after initial failures by improving connectivity between building components. These measures ensure that the loads supported by the failed components are redistributed to the rest of the structural system8,9. However, increased connectivity can contribute to collapsing elements pulling down parts of a building that would otherwise be unaffected10. This risk is particularly important when large initial failures occur, as tends to be the case in the most disastrous collapses6. Here we present an original design approach to arrest collapse propagation after major initial failures. When a collapse initiates, the approach ensures that specific elements fail before the failure of the most critical components for global stability. The structural system thus separates into different parts and isolates collapse when its propagation would otherwise be inevitable. The effectiveness of the approach is proved through unique experimental tests on a purposely built full-scale building. We also demonstrate that large initial failures would lead to total collapse of the test building if increased connectivity was implemented as recommended by present guidelines. Our proposed approach enables incorporating a last line of defence for more resilient buildings., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the Horizon 2020 research and innovation programme of the European Union (grant agreement no. 101000396). We acknowledge the assistance of the following colleagues from the ICITECH-UPV institute in preparing and executing the full-scale building tests: J. J. Moragues, P. Calderon, D. Tasquer, G. Caredda, D. Cetina, M. L. Gerbaudo, L. Marin, M. Oliver and G. Sempertegui. We are also grateful to the Levantina, Ingenieria y Construccion S.L. (LIC) company for providing human resources and access to their facilities for testing. Finally, we thank A. Elfouly and Applied Science International for their support in performing simulations.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Robustness of a full-scale precast building structure after edge column failure

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
[EN] A full-scale purposely built precast concrete building, designed to comply with robustness requirements in current building codes, was subjected to two different scenarios of sudden edge-column removal under the accidental load combination established by the codes. The main aim of this study was to assess how the structural system can prevent collapse initiation after the removal of a single edge column at different locations. This building was later subjected to a larger initial failure with the aim of arresting collapse propagation as part of another piece of research and outside the scope of this specific study. The building was highly instrumented providing unique data at a building system level for the understanding of the development of alternative load paths after the column removals. This work is novel since existing tests of edge-column removal from precast systems correspond mostly to simplified beam-column-slab subassemblies where the interaction with the rest of the building is neglected. The results obtained from this work are particularly relevant towards understanding the role of tying systems used in precast concrete buildings under different accidental scenarios using typical load combinations defined in building codes. The structure was able to redistribute the loads after each column was removed due to a combination of Vierendeel and compressive arching and membrane actions, leading to very small deflections. The role of vertical, horizontal, and floor tying systems in providing continuity between prefabricated and hybrid members was analysed in view of the experimental results obtained. The response obtained differed significantly from design assumptions commonly adopted for tying systems that rely on tensile catenary action at large deflections. This research is timely considering the push to adopt prefabricated components in building construction driven by Net Zero targets while maximising robustness of buildings subjected to more extreme events exacerbated by climate change., The authors wish to acknowledge the funding received by Grant BIA2017-88322-R-AR funded by MCIN/AEI/10.13039/501100011033 and "ERDF A Way of Making Europe", and by a project (Endure) that has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant agreement No. 101000396) . The authors would also like to ex-press their gratitude for funding received under the postdoctoral programs of the Generalitat Valenciana/Fons Social Europeu [APOSTD/2019/101] and Grant IJC2020-042642-I funded by MCIN/AEI/10.13039/501100011033 and by the "European Union NextGener-ationEU/PRTR". We are also grateful for the invaluable cooperation of the company Levantina, Ingenieria y Construccion S.L. (LIC) and the contribution of the members and collaborators of the ICITECH research group.