Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 29
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Introducing a novel experimental setup for assessing the progressive collapse resistance of structures

  • Setiawan, Andri
  • Cetina-Berdugo, Diego Fernando
  • Gerbaudo, Maria Luz
  • Marin, Lorenzo|||0000-0002-7117-1291
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Adam, Jose M|||0000-0002-9205-8458
[EN] The paper describes the development process of a novel experimental setup to assess the ability of a structural system to arrest collapse propagation. Unlike traditional pushdown tests, the proposed setup allows more realistic interactions of different failure modes during a collapse process. The adopted boundary conditions and loading protocol were designed and calibrated using advanced computational simulations representing full-building (global) responses. Then, a particular portion of the building (subassembly) was extracted, scaled down, and constructed in our laboratory. It is expected that the new setup will help to reveal new and insightful information about the progressive collapse phenomenon., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors would also like to express their gratitude for funding received under the postdoctoral programs of the Generalitat Valenciana/Fons Social Europeu [CIAPOS/2023/216] and for the Evolve project (ref. CIGE/2023/199).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Fusibles estructurales para evitar la propagación de fallos en las cimbras de edificación

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Calderón García, Pedro Antonio|||0000-0002-9783-9333
  • Moragues, Juan J|||0000-0001-8111-5480
  • Oliver-Cano, Marina
  • Adam, Jose M|||0000-0002-9205-8458
[ES] La construcción de edificios con estructura de hormigón armado se realiza, habitualmente, con la ayuda de puntales metálicos que se encargan de transmitir las cargas de las plantas recién hormigonadas a las inferiores. Los principales problemas que presenta el empleo de puntales son: a) la aparición de cargas superiores a las previstas en los puntales, pudiendo provocar el colapso de toda la cimbra o incluso del edificio, b) la heterogeneidad de las cargas que reciben los puntales de una misma planta cimbrada, y c) la limitada variedad de puntales de que disponen las casas comerciales. Todo ello obliga a que, en la mayor parte de las ocasiones, los puntales empleados en las obras estén claramente sobredimensionados. En este artículo se presenta el fusible estructural para el control de la carga de los puntales (también llamado limitador de carga o LL por sus siglas en inglés), que fue desarrollado en ICITECH a partir de estudios teóricos avanzados, una intensa campaña experimental y la ejecución de una prueba de concepto. El artículo se compone de: 1) una breve recopilación de los trabajos experimentales y de validación computacional llevados a cabo; y 2) el estudio realizado con simulación numérica avanzada para evaluar y cuantificar la posible mitigación del daño y el riesgo de fallo de estructuras de edificios durante su construcción. De los resultados obtenidos se puede afirmar que con el uso de LLs se consigue una mejora: de la seguridad, frente a fallos locales de la cimbra cuyas consecuencias podrían propagarse de forma desproporcionada; de la eficiencia estructural, con una mayor uniformidad en las cargas que reciben los puntales; y de los costes del sistema de apuntalamiento., Los autores quieren expresar su gratitud a todas las entidades por la financiación recibida (FPU13/02466; PRX17/00302; GV/2015/063; APOSTD/2019/101; 101000396; IJC2020- 042642-I), así como a las empresas Encofrado J. Alsina S.A. y Levantina, Ingeniería y Construcción S.L. por su invalorable cooperación.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Structural fuse-based segmentation for limiting disproportionate building collapse: design requirements

  • Gerbaudo, Maria Luz|||0009-0003-2838-0316
  • Setiawan, Andri
  • Adam, Jose M|||0000-0002-9205-8458
[EN] Our changing world exposes buildings to extreme events, causing localised failure that can spread and lead to a larger collapse. Existing standards and solutions focused solely on continuity that might be ineffective for extreme scenarios with large initial failures. This article presents a novel approach that combines continuity and segmentation called "fuse-based segmentation philosophy", taking advantage of the benefits of each. By subjecting a building to column losses through computational modelling, we can understand the behaviour of the building and ensure safety by allowing continuity in case of minor failures and segmentation in case of major collapses. Different failures are investigated to increase our understanding of the phenomenon, and various structural fuses are explored to prevent building col- lapses., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant agree- ment No. 101000396).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Learning from the progressive collapse of buildings

  • Caredda, Giacomo|||0000-0002-6888-0409
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
  • Chryssanthopoulos, Marios
[EN] As building structures in different parts of the world become increasingly exposed to extreme events, there has been a notable research and professional effort to ensure the design of more robust buildings which are insensitive to local failures. At the same time, several works performed in the field of forensic structural engineering have contributed to advancing knowledge on causes and risk factors of structural failure. This includes the creation of several collapse databases, most of which focus mainly on the underlying hazards causing failure. While such databases have provided invaluable insights for preventing structural failures, they do not lend themselves well to the analysis of how failure propagates, which can be useful for improving the progressive collapse resistance of buildings. To this end, a novel database of building collapses is presented in this article which systematically collects information on the hazards, initial failures and their corresponding propagation mechanisms. In addition, key information related to the context and the consequences of collapse is also gathered. Based on the information compiled in the database, this article provides an in-depth analysis of the most commonly occurring initial failures and propagation mechanisms, with significant conclusions extracted from the study of past collapses. The application of different consequence models for estimating fatalities and reconstruction costs is also presented, leading to recommendations for improving such models and related data collection strategies., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union 's Horizon 2020 research and innovation programme (Grant agreement No. 101000396) . The authors are also very grateful to Ramon Hingorani and Peter Tanner for kindly sharing the database they employed to develop their consequence model.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Tests on a Full-Scale Precast Building for Robustness Assessment

  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] As modern society faces unprecedented challenges related to climate stability and conflict, the need to design more sustainable and resilient buildings is undeniable. Several studies show that building with precast concrete components can result in significant advantages with respect to sustainability. However, the fact that such structures exhibit clear lines of weakness at the joints between elements can make them more vulnerable to progressive collapse. Although this can be overcome by adequate detailing of connections, there exist several uncertain factors which may affect the interaction between different precast elements and the global behaviour of such structural systems. This means that experimental testing is usually required for safe development of adequate solutions. Despite this fact, there have been very few studies on the robustness of precast concrete structures when compared to research on cast-in-place and steel structures. As such, this work presents the results of an ambitious experimental campaign involving the sudden removal of 3 different columns from a specifically built 15 m x 12 m two-storey precast concrete building incorporating simple and practical solutions to enhance robustness., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union¿s Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors would like to acknowledge the funding received through grant BIA2017-88322-R-AR funded by MCIN/AEI/ 10.13039/501100011033 and ¿ERDF A way of making Europe¿. The authors would also like to express their gratitude for funding received under the postdoctoral programs of Generalitat Valenciana/European Social Fund [APOSTD/2019/101] and grant IJC2020-042642-I funded by MCIN/AEI/ 10.13039/501100011033 and by ¿European Union NextGenerationEU/PRTR¿. The help and support provided by Ayman El-Fouly (Applied Science International) for performing simulations in ELS is also gratefully acknowledged. Finally, the authors are also grateful for the invaluable cooperation of the Levantina, Ingeniería y Construcción S.L. (LIC) company, and the contribution of members and collaborators of the Building Resilient research group.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

A simplified approach for modelling failure propagation of steel structures

  • Marin, Lorenzo|||0000-0002-7117-1291
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] Assessing the likelihood of progressive collapse in buildings resulting from the local failure of individual structural elements is challenging, especially in steel buildings. Engineers invest significant effort in modelling various connections between structural members, requiring detailed 3D solid elements. The complexity and computation time increase exponentially when analysing an entire building instead of local subassemblies. This study presents a practical methodology for modelling steel structures to predict progressive collapse rapidly. It adopts the distributed plastic hinges approach and is able to accurately simulate large deformations expected in collapse scenarios. Suitable experimental tests were selected to validate the proposed methodology, revealing the sensitivity of predictions to modelling assumptions such as the positioning of the hinges, the plastic length of each hinge, the cross-section discretisation, and the material definition. Finally, a set of recommendations for the simplified modelling of steel structures is provided for practising engineers working in the progressive collapse domain., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union¿s Horizon 2020 research and innovation programme (Grant Agreement No. 101000396).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Large-Scale Tests on RC Purpose-Built Buildings for Improving Robustness

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Adam, Jose M|||0000-0002-9205-8458
  • Mezquida-Alcaraz, Eduardo J.
[EN] Although recent years have been marked by a substantial research effort on the progressive collapse of steel as well as cast-in-place and precast concrete structures, the fact is that almost all studies are focused on reduced-scale tests, tests on isolated frame structures, tests on substructures or analytical and numerical analysis. Within this context, large-scale tests avoid size effects and allow all resisting mechanisms that a structure can develop after an initial-local failure to be studied. This paper presents the case of large-scale tests performed on two purpose-built buildings: one made of cast-in-place concrete and the other with precast concrete elements. In both cases, sudden column removal scenarios were considered for the robustness assessment of the structural system. The structures were provided with simple solutions to enhance the robustness and arrest progressive collapse initiated by the sudden failure of a column. The cast-in-place concrete building had two 3 m high floors, with 2 × 2 bays of 5 m span length. The total in-plan dimensions of the building were 10 × 10 m2. This building was subjected to sudden corner column failure scenarios with and without the presence of infill masonry walls. The precast concrete structure also had two 3 m high floors, with 3 × 2 bays of 5 m and 6 m span, respectively. The total in-plan dimensions of the building were 15 × 12 m2. This building was subjected to sudden column failure scenarios for three different tests, involving the removal of: a corner column, an edge column in a frame parallel to the direction of one-way hollow-core slabs, and an edge column in a frame perpendicular to the one-way slabs. This paper presents and discusses a summary of the results and outcomes of these studies., The work for the cast-in-place concrete building was carried out with the support of a 2017 Leonardo Grant for Researchers and Cultural Creators from the BBVA Foundation. The work for the precast concrete building was carried out with the funding received through grant BIA2017-88322-R-AR funded by MCIN/AEI/10.13039/501100011033 and ERDF A way of making Europe. This research also serves as the basis of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 101000396). The authors would also like to express their gratitude to the Levantina, Ingeniería y Construcción S.L. (LIC) company for funding the construction of the building, and to the Generalitat Valenciana/Fons Social Europeu [APOSTD/2019/101], grant IJC2020-042642-I funded by MCIN/AEI/10.13039/501100011033 and by European Union NextGeneration EU/PRTR, and Universitat Politècnica de València [PAID-10-17] for funding received under different postdoctoral programs.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Natural fuse-segmentation to arrest failure propagation in precast concrete buildings

  • Adam, Jose M|||0000-0002-9205-8458
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Caredda, Giacomo|||0000-0002-6888-0409
  • Marin, Lorenzo|||0000-0002-7117-1291
  • Cetina-Berdugo, Diego Fernando|||0009-0008-2884-9694
  • Gerbaudo, Maria Luz|||0009-0003-2838-0316
  • Oliver-Cano, Marina
  • Tasquer-Val, Daniel
  • Sempertegui, Geovanny
[EN] Our previous work on precast construction has shown that sufficient structural robustness can be achieved by adequately designing the connection detailing to withstand a sudden column removal under the accidental load scenario. However, the behaviour of such a system under larger initial failure has not been investigated to date. This article presents one of the recent tests carried out by the Building Resilient research group of the Universitat Politècnica de València, where a full-scale precast building of 2 storeys (6 m) and 3 x 2 spans (15 x 12 m2) has been tested under removal of three columns. Preliminary computational simulations were performed using the applied element method (AEM) to design the load scenarios. The test results indicated that the precast system has a natural segmentation ability, which is beneficial to arrest the failure propagation, limiting the collapse extent to a minimum., This article is written as a part of a research project (Endure) funded by the European Research Council (ERC) under the European Union¿s Horizon 2020 research and innovation programme (Grant Agreement No. 101000396). The authors would also like to express their gratitude for funding received under the postdoctoral program IJC2020-042642-I funded by MCIN/AEI/10.13039/501100011033 and by the ¿European Union NextGenerationEU/PRTR¿.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Tesis doctoral (DoctoralThesis)

Diseño jerárquico eficiente para la mitigación del colapso progresivo en edificios prefabricados

  • Gerbaudo, Maria Luz
[ES]En las últimas décadas, el sector de la construcción ha experimentado un notable incremento en el uso de estructuras prefabricadas de hormigón armado, impulsado principalmente por la industrialización, la optimización de procesos constructivos y la necesidad de reducir tiempos de ejecución y costes. Paralelamente, el aumento de eventos extremos -ya sean accidentales o malintencionados-ha puesto de manifiesto la necesidad de desarrollar estructuras capaces de responder de manera robusta y segura frente a situaciones fuera de diseño. Sin embargo, las estructuras prefabricadas han estado tradicionalmente asociadas a una menor robustez estructural en comparación con las estructuras monolíticas, debido principalmente a la discontinuidad inherente de sus conexiones. Las normativas actuales promueven elevados niveles de continuidad estructural para garantizar mecanismos alternativos de transmisión de cargas y prevenir el colapso progresivo. No obstante, esta continuidad puede convertirse en un arma de doble filo: aunque permite redistribuir esfuerzos ante daños locales, también puede favorecer la propagación del daño y desencadenar colapsos de gran extensión frente a eventos severos. Ante esta problemática, la presente investigación parte de una revisión bibliográfica exhaustiva sobre tipologías de conexiones y estrategias de diseño aplicadas a estructuras prefabricadas, con el objetivo de identificar soluciones capaces de mejorar su comportamiento frente a acciones extremas. Asimismo, se analiza un ensayo experimental a gran escala desarrollado previamente por el grupo de investigación al que pertenece esta Tesis Doctoral, en el cual, mediante la aplicación de un diseño jerárquico, fue posible alcanzar un comportamiento dual: ante fallos menores, la estructura logró redistribuir las cargas de manera eficiente, mientras que ante daños severos se produjo una segmentación controlada que evitó la propagación total del colapso. Este equilibrio entre continuidad y segmentación constituye la principal inspiración de la investigación. No obstante, el objetivo de la tesis es avanzar un paso más allá, desarrollando una metodología de diseño que incorpore herramientas específicas para un diseño jerárquico eficiente orientado a la mitigación del colapso progresivo en edificios prefabricados. Dicha metodología se implementa y valida experimentalmente mediante dos ensayos de subestructuras a escala de laboratorio, considerando dos tipologías distintas de vigas y conexiones, con el propósito de ampliar el rango de aplicación y facilitar futuras extensiones a otras configuraciones estructurales. Los resultados obtenidos demuestran que, mediante un diseño eficiente, es posible alcanzar niveles incluso superiores de seguridad estructural con una menor cuantía de armado y reduciendo significativamente el daño estructural. Esto permite no solo mejorar la robustez y resiliencia de las estructuras prefabricadas, sino también disminuir los tiempos y costes de reparación tras eventos extremos, contribuyendo al desarrollo de edificaciones más seguras, sostenibles y adaptables., Aagradezco al European Research Council (ERC) por financiar el proyecto ENDURE en el marco del programa Horizon 2020 de la Unión Europea (Grant Agreement No. 101000396), así como el proyecto ENCAST Proof of Concept (PoC) (Grant Agreement No. 101188699).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Practical methodology for quantifying the structural robustness of RC building structures

  • Setiawan, Andri
  • Cetina-Berdugo, Diego Fernando|||0009-0008-2884-9694
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] Several structural robustness requirements have been included in building codes over the past two decades. These mainly include measures to prevent collapse after an initial component failure by ensuring a minimum level of continuity within the structural system so that loads supported by the failed component can be redis- tributed to the rest of the structural system. However, there is still a general lack of consensus on how to evaluate the effectiveness of these measures. The present study proposes a practical methodology to evaluate the struc- tural robustness of RC building structures by combining an efficient modelling strategy and suitable robustness indexes. The proposed computational modelling strategy for RC buildings accounts for relevant dynamic and nonlinear phenomena, including compressive arching, catenary action, and membrane effects. This strategy can be implemented at a reasonable computational expense in widely used commercial structural analysis software and has been validated by comparisons to selected experimental tests from the literature. The modelling strategy is then employed to compute four different robustness indexes proposed in the literature for three hypothetical building designs, allowing the indexes to be systematically compared. It was found that evaluating a system using multiple robustness indexes can provide a more holistic view of system performance compared to relying solely on a single index. Ultimately, the potential usefulness of the proposed methodology is demonstrated through two practical applications involving the estimation of component damage levels and the evaluation of different design and retrofitting solutions. Such a methodology can be useful for practising engineers to optimise the design of new buildings or to support decisions on the assessment and retrofitting of existing ones., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors would also like to express their gratitude for funding received under the postdoctoral programs of the Generalitat Valenciana/Fons Social Europeu [CIAPOS/2023/216] and for the Evolve project (ref. CIGE/2023/199).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Improving building robustness through fuse-segmentation

  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] As the impacts of climate change and emerging conflicts become more and more apparent, it is undeniable that more robust building structures are required for resilient societies to be able to thrive. In fact, there has been a growing research effort over the past few decades on structural robustness and progressive collapse. As a result, several building codes now include specific provisions for improving the progressive collapse resistance of building structures. At present, almost all methods for improving structural robustness included in relevant codes rely on providing extensive continuity within a structural system to ensure that alternative load paths are available to redistribute loads supported by a structural component after its failure. Although this approach has proven to be effective in many cases, certain situations do exist for which it may increase the risk of disproportionate collapse. These include, for example, cases of large initial failure or of buildings with wide spans between columns. In such situations, the remaining parts of a structural system may not be able to find a stable state of equilibrium after initial failure. Having extensive continuity can contribute to the collapsing part pulling down the rest of the structure. A possible approach for arresting failure propagation in these situations involves segmenting building structures. In fact, there exist several examples of real occurrences when the extent of a collapse was limited thanks to a building being segmented into different parts. This includes the partial collapse of the Pentagon (Washington, 2001) and of the terminal 2E building at Charles de Gaulle airport (Paris, 2004). Although segmentation was not necessarily introduced in building design for improving robustness in these cases, they do demonstrate its effectiveness in limiting the extent of progressive collapse. However, segmentation with weak borders does interrupt continuity, which has already proven its efficiency for redistributing loads in the case of small initial failures. To overcome this limitation, there exists the possibility of using structural fuses to connect different segments of a structure. Such fuses should be able to provide continuity for normal and accidental design situations considered by current building codes but would separate building segments when failure propagation is inevitable. In fact, a novel fuse-based segmentation design approach to limit the propagation of failures in building structures is currently being developed by the Endure project thanks to a grant of €2.5 million awarded by the European Research Council. This paper presents the framework being used within this project to i) develop a performance-based approach for the design of fuse-segmented buildings, ii) design and test structural fuses for selected building types, and iii) implement and validate the performance of structural fuses in full-scale buildings., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union¿s Horizon 2020 research and innovation programme (Grant Agreement No. 101000396). The authors would also like to express their gratitude for the postdoctoral Grant IJC2020- 042642-I funded by MCIN/AEI/10.13039/501100011033 and by the ¿European Union NextGenerationEU/PRTR¿.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Enhancing building robustness through a fuse-based segmentation framework

  • Caredda, Giacomo|||0000-0002-6888-0409
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
  • Chryssanthopoulos, Marios
[EN] The most widely used design approaches today for improving the robustness of buildings rely on improving continuity within the structural system to ensure that loads supported by failed components can be redistributed to the rest of the system. Although this is effective for small initial failures, it can increase the risk of disproportionate collapse after larger initial failures due to collapsing elements pulling down parts of the structure that would otherwise be unaffected. This form of continuity-enabled collapse propagation can be avoided by dividing a structure into different segments. However, completely separating parts of a building results in lower performance under operational conditions, against lateral loads, and after small initial failures. In fact, the advantages of both continuity and segmentation can be combined through a fuse-based segmentation approach in which predefined segment borders ensure connectivity after small initial failures but separate to isolate collapse after larger initial failures. To ensure that this approach is used effectively to improve the robustness of building structures, a design framework is proposed in this article to systematically consider relevant structural and geometric criteria in order to define suitable segmentation configurations for reinforced concrete and steel framed building structures. An application to a realistic case study is also presented to demonstrate the effectiveness of the proposed framework in enhancing structural robustness., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors also acknowledge funding received from the Generalitat Valenciana for the Evolve project (ref. CIGE/2023/199). Finally, the article has also benefitted from helpful conversations with Dr. Andri Setiawan (Universitat Polit`ecnica de Val`encia) on the proposed initial failure hierarchy verification.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Natural fuse-segmentation to arrest failure propagation in precast concrete buildings

  • Adam, Jose M|||0000-0002-9205-8458
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Caredda, Giacomo|||0000-0002-6888-0409
  • Marin, Lorenzo|||0000-0002-7117-1291
  • Cetina-Berdugo, Diego Fernando|||0009-0008-2884-9694
  • Gerbaudo, Maria Luz|||0009-0003-2838-0316
  • Oliver-Cano, Marina
  • Sempertegui, Geovanny
[EN] The use of precast concrete structures is rapidly increasing worldwide because of their advantages in terms of quality, safety, sustainability, and speed of construction. In the field of progressive collapse of structures, few experimental studies have been carried out to investigate its structural integrity or robustness when subjected to a local initial failure. Previous work by the authors has shown that sufficient structural robustness can be achieved by properly designing the connection detailing between the structural components to withstand a sudden column removal under the accidental load combination defined in the codes. However, some aspects remain open for scientific discussions, such as: ¿What would happen if the initial failures were not limited to the failure of a single column?¿. In such a scenario (multiple column removals or other large initial disturbances), it has been shown that the probability of local collapse propagating to the rest of the structure is significantly higher. This article presents one of the recent tests carried out by the Building Resilient research group of the Universitat Politècnica de València, where a full-scale precast building of 2 storeys (6m) and 3 x 2 spans (15 x 12 m2) has been tested under removal of three columns. The results indicate that the way in which the detailing was provided to the precast elements allowed the system to arrest the failure propagation and limit the collapse extent to a minimum. It can be argued that precast concrete structures naturally have fused connections that take advantage of continuity for small initial failures yet automatically segment the building into individual parts when failure propagation is inevitable., This article is written as part of a research project (Endure) funded by the European Research Council (ERC) under the European Union¿s Horizon 2020 research and innovation programme (Grant Agreement No. 101000396). The authors would also like to express their gratitude for funding received under the postdoctoral program IJC2020-042642-I funded by MCIN/AEI/10.13039/501100011033 and by the ¿European Union NextGenerationEU/PRTR¿.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Analysing the cost-effectiveness of improving building robustness through segmentation

  • Caredda, Giacomo|||0000-0002-6888-0409
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
  • Chryssanthopoulos, Marios
  • Stewart, Mark G.
[EN] Current design philosophies are not always able to guarantee the robustness of buildings, especially when extreme events cause initial failures for which alternative load paths cannot be effective. Fuse-based segmentation has the potential to address this shortcoming, by isolating collapse when its initiation is inevitable. However, no study has yet been performed to clarify under which conditions and in which contexts it can be a suitable solution to mitigate the risk of disproportionate building collapse. Most applicable frameworks for performing risk-based cost-benefit assessments cannot be directly applied to study fuse-based segmentation since they rely on overly simplified structural models that cannot represent collapse propagation phenomena. In this article, a scenario-based methodology is proposed for evaluating the cost-effectiveness of fuse-based segmentation. The proposed methodology was also applied to a case-study consisting of a six-storey reinforced concrete building, revealing that there are a wide range of contexts for which fuse-based segmentation can be cost-effective for this type of structure.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Breaking continuity to prevent catastrophic building collapse

  • Setiawan, Andri
  • Cetina-Berdugo, Diego Fernando
  • Gerbaudo, Maria Luz
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] It is increasingly difficult to predict all the hazards that buildings will face over their lifetime, highlighting the need to design robust structures that can tol- erate unforeseen damage. Typically, robustness is pursued by providing continuity within a structural system. While this strategy performs well in expected scenarios, it increases the risk of catastrophic collapse propagation when initial damage is large. Using high-fidelity simulations, we first identified and characterised the key mechanisms responsible for continuity-enabled collapse propagation in highly continuous building structures such as those made of cast-in-place reinforced concrete. Building on this understanding, we developed: 1) a design approach that employs bespoke force-regulating fuses to interrupt continuity when it becomes detrimental, and 2)anexperimental setup that allows system-level collapse propagation to be evaluated by testing only a representative part of a building. Overall, our work shows that con- tinuity can be selectively disengaged even in intrinsically continuous struc- tures and provides a cost-effective way of testing the next generation of solutions against unforeseen extreme events., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant agreement No. 101000396). N.M. acknowledges funding from the Generalitat Valenciana for the Evolve project (ref. CIGE/2023/199). A.S. acknowledges the funding provided by the La Caixa Foundation through the Postdoctoral Junior Leader Fellowships Retaining Call 2025 (Fellowship no. LCF/BQ/PR25/12110011).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Simplified Modelling Strategy For Evaluating Failure Propagation In Reinforced Concrete Structures

  • Cetina-Berdugo, Diego Fernando|||0009-0008-2884-9694
  • Setiawan, Andri
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] The progressive collapse of reinforced concrete (RC) structures involves a series of complex loadresisting mechanisms, including flexural, arching and catenary actions, among others. A detailed model comprised of 3D-solid elements with refined mesh and complex material models is typically adopted to accurately simulate these phenomena in new or existing buildings. However, this approach is computationally expensive and unsuitable for practical applications, especially when dealing with large models of real buildings. This study proposes practical modelling strategies that balance the accuracy of an RC structural response to an initial failure with a practical method of preparing and analysing the models. The proposed modelling approaches include a) the PMM¿lumped hinge (based on the FEMA- 356 guideline), b) a modification to the FEMA hinge, and c) the fibre¿distributed hinge. Several progressive collapse tests from the literature were simulated on RC subassemblies with various boundary conditions and loading scenarios from the literature to systematically validate and compare the different approaches. The results revealed that the PMM-lumped approach cannot accurately simulate the structure¿s response under large deformation mode (catenary) where plastic hinges (yielding of reinforcement) are typically formed at a more extended region along the member. The present study suggests that the fibre-distributed hinge is the most suitable approach for simulating the progressive collapse of structures. This finding is pertinent (yet also alarming) as some new studies in the progressive collapse field still adopt the traditional PMM-hinge approach, which may eventually lead to invalid conclusions., This article is written as part of the Endure Research Project funded by the European Research Council (ERC) under the European Union¿s Horizon 2020 Research and Innovation Programme (Grant Agreement No. 101000396). The authors would also like to express their gratitude for funding received under the postdoctoral program IJC2020-042642-I, funded by MCIN/AEI/10.13039/501100011033 and the ¿European Union NextGenerationEU/PRTR¿.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Limitations of Current Robustness Standards in Steel-Composite Buildings

  • Marin, Lorenzo|||0000-0002-7117-1291
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] Current design standards emphasize structural continuity to achieve resilient, safe, efficient and durable building structures. Incidents such as the collapse of the Plasco Building (2017, Iran) and the partial collapse of the Ministry of Foreign Affairs Building (2024, New Zealand) highlight how extraordinary events can cause failure of a steel-composite building, making it unsafe. Var-ious methods aim to enhance the robustness of steel structures against ex-treme events or local-initial failures. Prescriptive tying rules improve continui-ty by introducing a minimum number of continuous ties. The alternative load path method explicitly verifies load redistribution after an initial component failure. These methods rely on structural continuity to manage load redistri-bution and maintain stability after small initial failures. However, in larger failure scenarios, they can contribute to complete collapse. This study exam-ines a steel-composite building (7x3-bays, 10-meter spans, three sto-reys) designed by Eurocodes for common loads, wind, seismic and accidental actions. The goal is to assess the limitations of continuity-based methods and the risk of propagating an initial failure. Results aim to inform future stand-ards to improve designs and mitigate major structural failures., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant Agreement No. 101000396).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

A risk-based framework for enhancing the robustness of framed building structures through segmentation

  • Caredda, Giacomo|||0000-0002-6888-0409
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
  • Chryssanthopoulos, Marios
[EN] Ensuring suitable robustness and resilience in building construction is a major priority for contemporary society. The study of past structural collapses resulting in disastrous consequences has revealed shortcomings in current robustness regulations. Particularly in cases of large initial damage, the widespread practice of ensuring extensive continuity may prove counterproductive, contributing to the propagation of failures rather than limiting their extent. This research presents the principles of an innovative design approach aimed at arresting the propagation of structural collapse through the segmentation of buildings. A performance-based framework is here proposed to guide designers in preventive structural planning for improved resilience. A cost-benefit analysis, a key tool to quantify the benefit of this philosophy , is introduced in order to support design decisions in accordance with required performance objectives., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant Agree- ment No. 101000396).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Failure analysis after the progressive collapse of a precast building

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Setiawan, Andri
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Gerbaudo, Maria Luz|||0009-0003-2838-0316
  • Marin, Lorenzo|||0000-0002-7117-1291
  • Cetina-Berdugo, Diego Fernando|||0009-0008-2884-9694
  • Caredda, Giacomo|||0000-0002-6888-0409
  • Oliver-Cano, Marina
  • Adam, Jose M|||0000-0002-9205-8458
  • Sempértegui, Geovanny
[EN] As buildings have to face more frequent and intense extreme events due to a changing climate and rising geopolitical tensions, the need for more robust structures that are insensitive to initial failures is now arguably more important than ever before. In this context, this article presents an in-depth analysis of the damage and failures that occurred during the partial progressive collapse test of a purposely built 15×12 m precast building with two floors. The building was designed to ensure load redistribution after the failure of single columns and also to segment parts of the structure from a larger initial failure that inevitably triggers a collapse. The ability of the structure to arrest collapse propagation was tested experimentally successfully isolating the collapse to the initially affected area. Based on visual inspections supported by computational simulations, failure mechanisms occurring in the collapsed area and damages in the upright part of the structure are analysed in detail in this article. Mechanisms that enabled the separation of the building in two parts are also studied. The presented results lead to an improved understanding of failure mechanisms causing collapse propagation and provide insights on how such propagation can be arrested., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors would also like to express their gratitude for funding received under the postdoctoral Grant IJC2020-042642-I funded by MCIN/AEI/ 10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR", for funding received by the First Research Projects call (PAID-06-22) from the Vice-rectorate for Research of the Universitat Politecnica de Valencia, and for funding for open access charge by CRUE- Universitat Politecnica de Valencia. The research presented in this article would not have been possible without the assistance of the following colleagues from the ICITECH institute in preparing and executing the full-scale building test: Juan J. Moragues, Pedro A. Calderon, Daniel Tasquer, Ana Sanchez-Rodriguez, Eduardo J. Mezquida-Alcaraz and Ghobad Shahnazi. The authors are also grateful to the Levantina, Ingenieria y Construccion S.L. (LIC) company for providing human resources and access to their facilities for testing. Finally, the authors wish to thank Ayman Elfouly and Applied Science International-LLC for their support in performing simulations.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The effect of continuity reinforcement on the progression of collapse in reinforced concrete buildings

  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Adam, Jose M|||0000-0002-9205-8458
  • Orton, Sarah L.
[EN] Research performed on the progressive collapse of reinforced concrete buildings has led to the development of several design approaches relying on sufficient continuity reinforcement to provide alternative load paths that can prevent collapse after the failure of single columns. However, there are very few works examining the possible contribution that continuity reinforcement could have in pulling down parts of a structure that would otherwise be unaffected after large initial failures. This article presents the findings of a study based on validated simulations of a prototype building using the Applied Element Method (AEM). The results reveal that a large amount of continuity reinforcement can indeed contribute to more failure propagation after very large initial failures by transmitting more unbalanced forces to columns. It is also demonstrated that localised reductions in continuity reinforcement can prevent failure propagation after large initial failures. In addition, it is shown that this can be achieved while still allowing alternative load paths to develop after single-column failure as required by current codes and guidelines., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union ' s Horizon 2020 research and innovation programme (Grant agreement No. 101000396) . Funding for open access charge: CRUE-Universitat Politecnica de Valencia. The authors are also grateful to members of the ICITECH institute, and particularly Manuel Buitrago, for invaluable discussions on fuse -based segmentation.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Tesis doctoral (DoctoralThesis)

Segmentación con fusibles para evitar la propagación de fallos en estructuras de edificios de hormigón armado

  • Cetina-Berdugo, Diego Fernando
[ES] El incremento de los eventos extremos y la creciente vulnerabilidad del entorno construido han evidenciado la necesidad de desarrollar estrategias de diseño estructural orientadas a mejorar la robustez y la resiliencia de los edificios. En este contexto, las estructuras de hormigón armado ejecutadas in situ ofrecen ventajas significativas debido a su elevada continuidad estructural y a su capacidad de redistribución de esfuerzos. Sin embargo, esta misma continuidad puede favorecer la propagación del daño ante fallos locales severos, lo que genera escenarios de colapso progresivo. El análisis de colapsos históricos y de la literatura científica evidencia que los enfoques tradicionales de diseño se han centrado principalmente en maximizar la continuidad estructural mediante mecanismos de redistribución de cargas, como el enfoque de caminos de carga alternativos. No obstante, diversos estudios muestran que una continuidad excesiva puede facilitar la propagación del daño a lo largo del sistema estructural. Esta dualidad ha puesto de manifiesto la necesidad de explorar estrategias que combinen continuidad estructural con mecanismos de segmentación controlada. En este marco conceptual, surge la incorporación de fusibles estructurales como estrategia innovadora para controlar el colapso progresivo. Estos dispositivos se diseñan para activarse únicamente en escenarios extremos, introduciendo una jerarquía resistente que prioriza la protección de elementos críticos, como las columnas, mientras permite reducir la demanda mediante fallos controlados en elementos secundarios. De este modo, se establece un mecanismo de control del daño que compatibiliza la continuidad estructural en condiciones normales con la segmentación del sistema en situaciones críticas. Para materializar esta estrategia, se desarrolló un sistema de limitadores de fuerza basado en la modificación de los acopladores de barras de armado, lo que permite ajustar con precisión su capacidad resistente y controlar el momento de activación del fusible. Esta solución mantiene la compatibilidad con las técnicas constructivas convencionales, lo que facilita su implementación práctica en estructuras de hormigón armado ejecutadas in situ. Los ensayos experimentales confirmaron la viabilidad del dispositivo y su capacidad para actuar como elemento de control en la transferencia de esfuerzos. Finalmente, mediante una combinación de simulación numérica y ensayos experimentales en subestructuras representativas, se validó el comportamiento global del sistema estructural equipado con fusibles. Los resultados demuestran que, bajo condiciones adecuadas de rigidez global, los fusibles concentran las deformaciones y limitan la transmisión de esfuerzos a los elementos principales, lo que contribuye a interrumpir la propagación del colapso. En conjunto, esta investigación confirma que la implementación estratégica de fusibles estructurales constituye una herramienta eficaz para mejorar la robustez y controlar el mecanismo de colapso progresivo en edificios de hormigón armado., [EN] The increasing frequency of extreme events and the growing vulnerability of the built environment have highlighted the need to develop structural design strategies to improve the robustness and resilience of buildings. In this context, cast-in-place reinforced concrete structures offer significant advantages due to their high structural continuity and load redistribution capacity. However, this same continuity may facilitate the propagation of damage under severe local failures, potentially leading to progressive collapse. The analysis of historical collapses and the scientific literature shows that traditional design approaches have mainly focused on maximising structural continuity through load redistribution mechanisms, such as the alternate load path approach. Nevertheless, several studies indicate that excessive continuity may also facilitate the propagation of damage throughout the structural system. This duality underscores the need to explore strategies that combine structural continuity with controlled segmentation. Within this conceptual framework, the incorporation of structural fuses emerges as an innovative strategy for controlling progressive collapse. These devices are designed to activate only under extreme scenarios, introducing a resistance hierarchy that prioritises the protection of critical elements, such as columns, while reducing demand through controlled failures in secondary elements. In this way, a damage-control mechanism is established that reconciles structural continuity under normal conditions with system segmentation under critical situations. To implement this strategy, a force-limiting system was developed by modifying reinforcing bar couplers, allowing their resistance to be precisely adjusted and enabling control over the activation of the structural fuse. This solution remains compatible with conventional construction techniques, facilitating its practical implementation in cast-in-place reinforced concrete structures. Experimental tests confirmed the device's feasibility and its ability to act as a control element in force transfer. Finally, through a combination of numerical simulations and experimental tests on representative substructures, the global behaviour of the structural system equipped with fuses was validated. The results demonstrate that, under adequate global stiffness conditions, the fuses concentrate deformations and limit the transmission of forces to the primary structural elements, thereby contributing to interrupting collapse propagation. Overall, this research confirms that the strategic implementation of structural fuses constitutes an effective approach to improving robustness and controlling progressive collapse mechanisms in reinforced concrete buildings., [CA] El increment dels esdeveniments extrems i la creixent vulnerabilitat de l'entorn construït han evidenciat la necessitat de desenvolupar estratègies de disseny estructural orientades a millorar la robustesa i la resiliència dels edificis. En aquest context, les estructures de formigó armat executades in situ ofereixen avantatges significatius a causa de la seua elevada continuïtat estructural i de la seua capacitat de redistribució d'esforços. No obstant això, aquesta mateixa continuïtat pot afavorir la propagació del dany davant fallades locals severes, la qual cosa pot generar escenaris de col·lapse progressiu. L'anàlisi de col·lapses històrics i de la literatura científica evidencia que els enfocaments tradicionals de disseny s'han centrat principalment a maximitzar la continuïtat estructural mitjançant mecanismes de redistribució de càrregues, com l'enfocament de camins alternatius de càrrega. Tanmateix, diversos estudis mostren que una continuïtat excessiva pot facilitar la propagació del dany al llarg del sistema estructural. Aquesta dualitat ha posat de manifest la necessitat d'explorar estratègies que combinen la continuïtat estructural amb mecanismes de segmentació controlada. En aquest marc conceptual, la incorporació de fusibles estructurals apareix com una estratègia innovadora per a controlar el col·lapse progressiu. Aquests dispositius estan dissenyats per activar-se únicament en escenaris extrems, introduint una jerarquia resistent que prioritza la protecció d'elements crítics, com ara les columnes, mentre permet reduir la demanda mitjançant fallades controlades en elements secundaris. D'aquesta manera, s'estableix un mecanisme de control del dany que compatibilitza la continuïtat estructural en condicions normals amb la segmentació del sistema en situacions crítiques. Per a materialitzar aquesta estratègia, es va desenvolupar un sistema de limitadors de força basat en la modificació dels acobladors de barres d'armat, cosa que permet ajustar amb precisió la seua capacitat resistent i controlar el moment d'activació del fusible. Aquesta solució manté la compatibilitat amb les tècniques constructives convencionals, fet que facilita la seua implementació pràctica en estructures de formigó armat executades in situ. Els assaigs experimentals van confirmar la viabilitat del dispositiu i la seua capacitat per actuar com a element de control en la transferència d'esforços. Finalment, mitjançant una combinació de simulació numèrica i assaigs experimentals en subestructures representatives, es va validar el comportament global del sistema estructural equipat amb fusibles. Els resultats demostren que, sota condicions adequades de rigidesa global, els fusibles concentren les deformacions i limiten la transmissió d'esforços cap als elements principals, cosa que contribueix a interrompre la propagació del col·lapse. En conjunt, aquesta investigació confirma que la implementació estratègica de fusibles estructurals constitueix una eina eficaç per a millorar la robustesa i controlar el mecanisme de col·lapse progressiu en edificis de formigó armat., Agradezco al proyecto ENDURE, financiado por el European Research Council (ERC) en el marco del programa Horizon 2020 de la Unión Europea (Grant Agreement No. 101000396), cuya financiación ha hecho posible el contrato en el que se ha desarrollado este trabajo.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Arresting failure propagation in buildings through collapse isolation

  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] Several catastrophic building collapses1¿5 occur because of the propagation of local-initial failures6,7. Current design methods attempt to completely prevent collapse after initial failures by improving connectivity between building components. These measures ensure that the loads supported by the failed components are redistributed to the rest of the structural system8,9. However, increased connectivity can contribute to collapsing elements pulling down parts of a building that would otherwise be unaffected10. This risk is particularly important when large initial failures occur, as tends to be the case in the most disastrous collapses6. Here we present an original design approach to arrest collapse propagation after major initial failures. When a collapse initiates, the approach ensures that specific elements fail before the failure of the most critical components for global stability. The structural system thus separates into different parts and isolates collapse when its propagation would otherwise be inevitable. The effectiveness of the approach is proved through unique experimental tests on a purposely built full-scale building. We also demonstrate that large initial failures would lead to total collapse of the test building if increased connectivity was implemented as recommended by present guidelines. Our proposed approach enables incorporating a last line of defence for more resilient buildings., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the Horizon 2020 research and innovation programme of the European Union (grant agreement no. 101000396). We acknowledge the assistance of the following colleagues from the ICITECH-UPV institute in preparing and executing the full-scale building tests: J. J. Moragues, P. Calderon, D. Tasquer, G. Caredda, D. Cetina, M. L. Gerbaudo, L. Marin, M. Oliver and G. Sempertegui. We are also grateful to the Levantina, Ingenieria y Construccion S.L. (LIC) company for providing human resources and access to their facilities for testing. Finally, we thank A. Elfouly and Applied Science International for their support in performing simulations.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Robustness of a full-scale precast building structure after edge column failure

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
[EN] A full-scale purposely built precast concrete building, designed to comply with robustness requirements in current building codes, was subjected to two different scenarios of sudden edge-column removal under the accidental load combination established by the codes. The main aim of this study was to assess how the structural system can prevent collapse initiation after the removal of a single edge column at different locations. This building was later subjected to a larger initial failure with the aim of arresting collapse propagation as part of another piece of research and outside the scope of this specific study. The building was highly instrumented providing unique data at a building system level for the understanding of the development of alternative load paths after the column removals. This work is novel since existing tests of edge-column removal from precast systems correspond mostly to simplified beam-column-slab subassemblies where the interaction with the rest of the building is neglected. The results obtained from this work are particularly relevant towards understanding the role of tying systems used in precast concrete buildings under different accidental scenarios using typical load combinations defined in building codes. The structure was able to redistribute the loads after each column was removed due to a combination of Vierendeel and compressive arching and membrane actions, leading to very small deflections. The role of vertical, horizontal, and floor tying systems in providing continuity between prefabricated and hybrid members was analysed in view of the experimental results obtained. The response obtained differed significantly from design assumptions commonly adopted for tying systems that rely on tensile catenary action at large deflections. This research is timely considering the push to adopt prefabricated components in building construction driven by Net Zero targets while maximising robustness of buildings subjected to more extreme events exacerbated by climate change., The authors wish to acknowledge the funding received by Grant BIA2017-88322-R-AR funded by MCIN/AEI/10.13039/501100011033 and "ERDF A Way of Making Europe", and by a project (Endure) that has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant agreement No. 101000396) . The authors would also like to ex-press their gratitude for funding received under the postdoctoral programs of the Generalitat Valenciana/Fons Social Europeu [APOSTD/2019/101] and Grant IJC2020-042642-I funded by MCIN/AEI/10.13039/501100011033 and by the "European Union NextGener-ationEU/PRTR". We are also grateful for the invaluable cooperation of the company Levantina, Ingenieria y Construccion S.L. (LIC) and the contribution of the members and collaborators of the ICITECH research group.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Enhancing Building Robustness Through a Novel Risk-Based Segmentation Strategy: A Case Study

  • Caredda, Giacomo|||0000-0002-6888-0409
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
  • Chryssanthopoulos, Marios
[EN] The disproportionate collapse of building structures is a matter of growing concern. Current design strategies have been shown to have limitations in ensuring adequate robustness when dealing with large initial failures, which can impact the structural safety. This research has developed a novel risk-based strategy to enhance building robustness through segmentation. The proposed methodology involves the identification of an optimal segmentation configuration, with this being based on structural and geometric criteria. Following this, a cost-benefit analysis is developed to evaluate the efficiency of the proposed solution. To illustrate the application of the proposed strategy, a case study has been identified in which the segmentation strategy is applied, and the cost-effectiveness of the identified solution is evaluated., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant Agreement No. 101000396). The authors also acknowledge funding received from the Generalitat Valenciana for the Evolve project (ref. CIGE/2023/199).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Partial collapse tests of a precast concrete building specimen

  • Setiawan, Andri
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] The paper describes a new design approach, so-called hierarchy-based collapse isolation, to arrest fail-ure propagation in buildings. The approach ensures that buildings have sufficient resistance to withstand loads under operational conditions and small initial failures. Yet, some connector elements are deliber-ately designed to break to isolate the collapse when failure propagation is inevitable. To validate the proposed concept, a two-storey purpose-built precast building specimen with 12 m × 15 m plan dimen-sions was tested and the main findings are discussed here. The work is expected to promote the wider adoption of robust precast systems, contributing to more resilient and sustainable buildings., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors would also like to express their gratitude for funding received under the postdoctoral programs of the Generalitat Valenciana/Fons Social Europeu [CIAPOS/2023/216] and for the Evolve project (ref. CIGE/2023/199).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Incorporación de una nueva última línea de defensa frente a colapsos progresivos en estructuras de hormigón prefabricadas, Incorporating a new last line of defence against progressive collapse in precast concrete structures

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Adam, Jose M|||0000-0002-9205-8458
[EN] The paper describes a new design approach, so-called hierarchy-based collapse isolation, to arrest failure propagation in buildings. The approach ensures that buildings have sufficient resistance to withstand loads under operational conditions and small initial failures. Yet, some connector elements are deliberately designed to break to isolate the collapse when failure propagation is inevitable. To validate the proposed concept, a two-storey purpose-built precast building specimen with 12 m × 15 m plan dimensions was tested and the main findings are discussed here. The work is expected to promote the wider adoption of robust precast systems, contributing to more resilient and sustainable buildings., Este artículo forma parte de un proyecto (Endure) que ha recibido financiación del Consejo Europeo de Investigación (ERC) en el marco del programa de investigación e innovación Horizonte 2020 de la Unión Europea (Grant agreement No. 101000396). Los autores también desean expresar su agradecimiento por la financiación recibida en el marco de los programas postdoctorales IJC2020-042642-I financiada por MCIN/AEI/10.13039/501100011033 y por la «NextGenerationEU/PRTR» de la Unión Europea, de la Generalitat Valenciana/Fons Social Europeu [CIAPOS/2023/216] y del proyecto Evolve (ref. CIGE/2023/199).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

On the Effectiveness of Fuse-Based Segmentation for Improving the Robustness of Buildings

  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Caredda, Giacomo|||0000-0002-6888-0409
  • Setiawan, Andri
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] There has been a considerable research effort over the past few decades on better understanding and avoiding the progressive collapse of building structures. As a result, current building codes now include provisions to prevent the occurrence of this phenomenon. Most of these measures rely on providing extensive continuity so that alternative load paths are available to redistribute loads after the initial failure of a component. This form of load redistribution can be an effective way of preventing collapse initiation after the failure of single columns. However, after larger initial failures, continuity can promote rather than prevent failure propagation by enabling collapsing parts to pull down parts of the structure that would otherwise be unaffected. In such situations, dividing the structure into different segments can be a more effective way of isolating an initial failure and preventing its propagation. Nevertheless, implementing a segmentation design strategy that completely interrupts continuity would entail reducing safety under operational conditions and after small initial failures. To overcome these limitations, a fuse-based segmentation design approach can be used to combine the advantages of both continuity and segmentation. Using this approach, buildings are not only designed to have sufficient connectivity to prevent collapse after small initial failures, but they are also designed to segment and isolate collapse after large initial failures. Although it has recently been demonstrated that it is possible to design buildings that perform as intended by the fuse-based segmentation approach, it is still not well understood when the approach can be advantageous. As such, this work makes use of collapse simulations based on the Applied Element Method (AEM) to identify initial failure scenarios in which continuity can contribute to more disproportionate collapse for a specific case study involving a reinforced concrete framed building structure., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors also acknowledge funding received from the Generalitat Valenciana for the Evolve project (ref. CIGE/2023/199).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Colapso progresivo y robustez de edificios y puentes, Progressive collapse and robustness of buildings and bridges

  • Adam, Jose M|||0000-0002-9205-8458
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
[ES] Los últimos años han estado marcados por un número cada vez más elevado de estudios sobre el colapso progresivo y la robustez estructural como consecuencia de la persistente aparición y aparentemente creciente frecuencia de fallos estructurales catastróficos. En la actualidad, la gran mayoría de estos estudios se centran en simulaciones computacionales y en pruebas de laboratorio de subestructuras a escala reducida. Aunque esta filosofía de estudio ha permitido avanzar sustancialmente en la materia, estas estrategias se caracterizan por sus importantes limitaciones, que sólo pueden superarse mediante ensayos a escala real de las estructuras. Este artículo presenta algunos de los principales trabajos de investigación realizados en este sentido por el grupo de investigación Building Resilient del instituto ICITECH de la Universitat Politècnica de València. Se presentan los trabajos más importantes relacionados con el cimbrado de edificios, las estructuras de edificios de hormigón armado ejecutadas in situ y prefabricadas, los puentes metálicos en celosía y los edificios segmentados por fusibles, junto con los resultados más significativos obtenidos hasta el momento., Estos trabajos no hubieran dado sus frutos sin la financiación y ayuda recibidas por: FGV (Ferrocarrils de la Generalitat Valenciana), Calsens, Ministerio de Ciencia e Innovación, Generalitat Valenciana, Ministerio de Educación y Formación Profesional, Fundación BBVA, European Research Council, LIC Levantina, Ingeniería y Construcción, y Encofrados Alsina.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

A Framework for Improving Building Robustness Through Segmentation

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Adam, Jose M|||0000-0002-9205-8458
[EN] The protection of buildings and infrastructures from extreme abnormal events due to natural hazards (e.g. hurricanes, floods), accidents (e.g. vehicle impact, gas explosions, unexpected failure due to poor design or lack of maintenance) and malicious actions (e.g. terrorist attacks), is currently of great societal and scientific concern. To prevent the spreading of a local-initial damage into progressive collapse, the current design philosophies consider that when a critical element fails (e.g. column, load-bearing wall), continuity structural details should provide alternative load paths to redistribute the load of the failed element to the rest of the structure. Although this strategy is valid in certain situations (e.g. small initial failure), in others (e.g. large initial failure due to blast loading), it has proved to be mistaken and has led to disastrous consequences. Over recent years, a debate has emerged about whether or not segmentation can improve a building¿s capacity to arrest progressive collapse. Segmenting a building into individual parts can prevent failures in one zone from propagating to other parts of the structure, as was the case, for example, in the Pentagon (2001) and Terminal 3 of the Charles de Gaulle Airport (2004). However, segmentation breaks continuity, which works well for small initial failure scenarios. In the context of an ERC-Consolidator Grant project, the use of structural fuses has been proposed. While fuses will provide continuity under normal loads or for small local-initial failures currently considered by relevant standards, they will separate to prevent disproportionate collapse during more extreme situations when failure propagation is inevitable. This paper presents the first achievements of the project, involving the development of a framework that can be employed to identify situations when continuity is disadvantageous and for which segmentation is beneficial., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 101000396). The authors would also like to express their gratitude for funding received under the postdoctoral Grant IJC2020¿042642- I funded by MCIN/AEI/ https://doi.org/10.13039/501100011033 and by the ¿European Union NextGenerationEU/PRTR¿.