Publicación Artículo científico (JournalArticle)

Adaptive threshold generation in robust fault detection using interval models: time-domain and frequency-domain approaches

  • Puig, Vicenç
  • Montes de Oca, Saúl
  • Blesa, Joaquim
In this paper, robust fault detection is addressed on the basis of evaluating the residual energy that it is compared against worst-case value (threshold) generated considering parametric modeling uncertainty using interval models. The evaluation of the residual/threshold energy can be performed either in the time or frequency domain. This paper proposes methods to compute such energy in the two domains. The first method generates the adaptive threshold in the time domain through determining the worst-case time evolution of the residual energy using a zonotope-based algorithm. The second method evaluates the worst-case energy evolution in the frequency domain using the Kharitonov polynomials. Results obtained using both approaches are related through the Parseval's theorem. Finally, two application examples (a smart servoactuator and a two DOFs helicopter) will be used to assess the validity of the proposed approaches and compare the results obtained. Copyright © 2012 John Wiley & Sons, Ltd., Funded by: CICYT SHERECS. Grant Number: DPI2011- 26243 and European Commission. Grant Number: i-Sense FP7-ICT-2009-6-270428., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A virtual actuator and sensor approach for fault tolerant control of LPV systems

  • Rotondo, Damiano
  • Nejjari, Fatiha
  • Puig, Vicenç
In this paper, a fault tolerant control (FTC) strategy using virtual actuators and sensors for linear parameter varying (LPV) systems is proposed. The main idea of this FTC method, initially developed for LTI systems, is to reconfigure the control loop such that the nominal controller could still be used without need of retuning it. The plant with the faulty actuator/sensor is modified adding the virtual actuator/sensor block that masks the actuator/sensor fault. The suggested technique is an active FTC strategy that reconfigures the virtual actuator/sensor on-line taking into account faults and operating point changes. The stability of the reconfigured control loop is guaranteed if the faulty plant is stabilizable/detectable. The LPV virtual actuator/sensor is designed using polytopic LPV techniques and linear matrix inequalities (LMIs). A two-tank system simulator is used to assess the performance of the proposed method. In particular, it is shown that the application of the proposed technique results in an improvement, in terms of performance, with respect to the LTI counterpart. © 2014 Elsevier Ltd., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428), by UPC through the grant FPI-UPC E-01104 and by AGAUR through thecontract FI-DGR 2013 (ref. 2013FIB00218)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Combining learning in model space fault diagnosis with data validation/reconstruction: Application to the Barcelona water network

  • Quevedo, Joseba
  • Chen, Hung
  • Cugueró-Escofet, Miquel Àngel
  • Puig, Vicenç
  • Sarrate, Ramon
In this paper, an integrated data validation/reconstruction and fault diagnosis approach is proposed for critical infrastructure systems. The proposed methodology is implemented in a two-stage approach. In the first stage, sensor communication faults are detected and corrected, in order to facilitate a reliable dataset to perform system fault diagnosis in the second stage. On the one hand, sensor validation and reconstruction are based on the combined use of spatial and time series models. Spatial models take advantage of the (mass-balance) relation between different variables in the system, whilst time series models take advantage of the temporal redundancy of the measured variables by means of Holt-Winters time series models. On the other hand, fault diagnosis is based on the learning-in-model-space approach that is implemented by fitting a series of models using a series of signal segments selected with a sliding window. In this way, each signal segment can be represented by one model. To rigorously measure the 'distance' between models, the distance in the model space is defined. The deterministic reservoir computing approach is used to approximate a model with the input-output dynamics that exploits spatial-temporal correlations existing in the original data. Finally, the proposed approach is successfully applied to the Barcelona water network. © 2014 Elsevier Ltd., This work is supported by the European Union Seventh Framework Programme, in the framework of the iSense project,under Grant agreement no. INSFO-ICT-270428., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig, Vicenç
  • Garza-Castañón, Luis E.
  • Rosich, Albert
This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license., This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach. © 2013 by the authors; licensee MDPI, Basel, Switzerland., This work is supported by the Research Chair in Supervision and Advanced Control of Tecnológico de Monterrey, Campus Monterrey and by a CONACYT studentship. This work has been partially grant-funded by CICYTSHERECSDPI-2011-26243 and CICYT WATMANDPI-2009-13744 of the Spanish Ministry of Education, by iSense grant FP7-ICT-2009-6-270428 and by EFFINETgrant FP7-ICT-2012-318556 of the European Commission. This work is also partially founded by the Fond National de la Recherche, Luxembourg (CO11/IS/1206050)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

FDI and FTC of wind turbines using the interval observer approach and virtual actuators/sensors

  • Blesa, Joaquim
  • Rotondo, Damiano
  • Puig, Vicenç
  • Nejjari, Fatiha
In this work, the problem of Fault Detection and Isolation (FDI) and Fault Tolerant Control (FTC) of wind turbines is addressed. Fault detection is based on the use of interval observers and unknown but bounded description of the noise and modeling errors. Fault isolation is based on analyzing the observed fault signatures on-line and matching them with the theoretical ones obtained using structural analysis and a row-reasoning scheme. Fault tolerant control is based on the use of virtual sensors/actuators to deal with sensor and actuator faults, respectively. More precisely, these FTC schemes, that have been proposed previously in state space form, are reformulated in input/output form. Since an active FTC strategy is used, the FTC module uses the information from the FDI module to replace the real faulty sensor/actuator by activating the corresponding virtual sensor/actuator. Virtual actuators/sensors require additionally a fault estimation module to compensate the fault. In this work, a fault estimation approach based on batch least squares is used. The performance of the proposed FDI and FTC schemes is assessed using the proposed fault scenarios considered in the wind turbine benchmark introduced in IFAC SAFEPROCESS 2009. Satisfactory results have been obtained in both FDI and FTC. © 2013 Elsevier Ltd., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428), by UPC through the grant FPIUPC E-01104 and by AGAUR through the contract FI-DGR 2013FIB00218., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Actuator-fault detection and isolation based on set-theoretic approaches

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
Energy Efficient Buildings Special Issue., In this paper, an actuator-fault detection and isolation (FDI) approach is proposed. The FDI approach is based on a bank of interval observers, each of which is designed to match a healthy or faulty system mode. To ensure reliable FDI for all considered actuator faults, a collection of invariant set-based FDI conditions are established for the proposed technique. Under these guaranteed FDI conditions, all the considered faults can be detected and isolated during the transition induced by fault occurrences. Comparing with the existing set-based FDI approaches, the advantage of the proposed technique consists in that it combines the advantages of interval observers in the transient-state functioning and the advantages of invariant sets in the steady-state functioning. This paper is completed with the study of a continuous stirred-tank reactor (CSTR), which illustrates the effectiveness of the proposed method., The work has been supported by the DGR of Generalitat de Catalunya (SAC group Ref.2009/SGR/1491), the grant SHERECS DPI2011- 26243, European Commission through contract i-Sense (FP7-ICT-2009-6-270428) and China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Closed-loop actuator-fault detection and isolation using set tubes and invariant sets

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
Trabajo presentado al 19th IFAC World Congress celebrado del 24 al 29 de agosto de 2014 en Cape Town (Sudafrica)., This paper proposes a new actuator-fault detection and isolation (FDI) strategy for closed-loop discrete time-invariant systems by using set tubes and invariant sets. In this approach, invariant sets are used for FDI and to establish FDI conditions, while set tubes are only generated for fault isolation (FI) during the transient state. Comparing to the existing relevant set-theoretic FDI techniques, the advantage of this approach consists in that it exhibits a balance between the conservativeness of FDI conditions and the rapidity of FI. The effectiveness of the proposed technique is illustrated by a numerical example., The work was supported by the DGR of Generalitat de Catalunya (AGAUR Doctorat Industrial 2013-DI-041), European Commission through contract i-Sense (FP7-ICT-2009-6-270428), and China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Model-based leak detection and location in water distribution networks considering an extended-horizon analysis of pressure sensitivities

  • Casillas, Myrna V.
  • Garza-Castañón, Luis E.
  • Puig, Vicenç
In this paper, we propose a new approach for model-based leak detection and location in water distribution networks (WDN), which considers an extended time-horizon analysis of pressure sensitivities. Five different ways of using the leak sensitivity matrix to isolate the leaks are described and compared. The first method is based on the binarization approach. The second, third and fourth methods are based on the comparison of the measured pressure vectors with the leak sensitivity matrix using different metrics: correlation, angle between vectors and Euclidean distance, respectively. The fifth method is based on the least square optimization method. The performance of these methods is compared when applied to two academic small networks (Hanoi and Quebra) widely used in the literature. Finally, the three methods with better performance are applied to a district metering area of the Barcelona WDN using real data., This work is supported by the Research Chair in Supervision and Advanced Control of Tecnológico de Monterrey, Campus Monterrey and by a CONACYT studentship. This work has been partially grant-funded by CICYT SHERECS DPI-2011-26243 and CICYT WATMAN DPI- 2009-13744 of the Spanish Ministry of Education and by iSense grant FP7-ICT-2009-6-270428 and by EFFINET grant FP7-ICT-2012-318556 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Sensor placement for leak detection and location in water distribution networks

  • Sarrate, Ramon
  • Blesa, Joaquim
  • Nejjari, Fatiha
  • Quevedo, Joseba
Trabajo presentado al 7th IWA International Conference on Efficient Use and Management of Water (Efficient 2013), celebrado en Paris (Francia) del 22 al 25 de octubre de 2013., The performance of a leak detection and location algorithm depends on the set of measurements that are available in the network. This work presents an optimization strategy that maximizes the leak diagnosability performance of the network. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of diagnosability while the sensor configuration cost satisfies a budgetary constraint. To efficiently handle the complexity of the distribution network an efficient branch and bound search strategy based on a structural model is used. However, in order to reduce even more the size and the complexity of the problem the present work proposes to combine this methodology with clustering techniques. The strategy developed in this work is successfully applied to determine the optimal set of pressure sensors that should be installed in a District Metered Area in the Barcelona water distribution network., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), and by the European Commission through contracts i-Sense (ref. FP7-ICT-2009-6-270428) and EFFINET (ref. FP7-ICT2011-8-318556)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Robust quasi-LPV model reference FTC of a quadrotor UAV subject to actuator faults

  • Rotondo, Damiano
  • Nejjari, Fatiha
  • Puig, Vicenç
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License. (CC BY-NC-ND 3.0)., A solution for fault tolerant control (FTC) of a quadrotor unmanned aerial vehicle (UAV) is proposed. It relies on model reference-based control, where a reference model generates the desired trajectory. Depending on the type of reference model used for generating the reference trajectory, and on the assumptions about the availability and uncertainty of fault estimation, different error models are obtained. These error models are suitable for passive FTC, active FTC and hybrid FTC, the latter being able to merge the benefits of active and passive FTC while reducing their respective drawbacks. The controller is generated using results from the robust linear parameter varying (LPV) polytopic framework, where the vector of varying parameters is used to schedule between uncertain linear time invariant (LTI) systems. The design procedure relies on solving a set of linear matrix inequalities (LMIs) in order to achieve regional pole placement and H∞ norm bounding constraints. Simulation results are used to compare the different FTC strategies., This work has been funded by the Spanish MINECO through the project CICYT SHERECS (ref. DPI2011-26243), by the European Commission through the contract i-Sense (ref. FP7-ICT-2009-6-270428), by AGAUR through the contracts FI-DGR 2013 (ref. 2013FIB00218) and FI-DGR 2014 (ref. 2014FI_ B1 00172), and by the DGR of Generalitat de Catalunya (SAC group ref. 2014/SGR/374)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A fault-hiding approach for the switching quasi-LPV fault-tolerant control of a four-wheeled omnidirectional mobile robot

  • Rotondo, Damiano
  • Puig, Vicenç
  • Nejjari, Fatiha
  • Romera, Juli
This paper proposes a reference model approach for the trajectory tracking of a four-wheeled omnidirectional mobile robot. In particular, the error model is brought to a quasi-linear-parameter-varying (LPV) form suitable for designing an error-feedback controller. It is shown that, if polytopic techniques are used to reduce the number of constraints from infinite to finite, a solution within the standard LPV framework could not exist due to a singularity that appears in the possible values of the input matrix. Adding a switching component to the controller allows solving this problem. Moreover, a switching LPV virtual actuator is added to the control loop in order to obtain fault tolerance within the fault-hiding paradigm, keeping the stability and some desired performances under the effect of actuator faults without the need of retuning the nominal controller. The effectiveness of the proposed approach is shown and proved through simulation and experimental results., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428), by AGAUR through the contracts FI-DGR 2013 (ref. 2013FIB00218) and FI-DGR 2014 (ref. 2014FI B1 00172) and by the DGR of Generalitat de Catalunya (SAC group Ref. 2014/SGR/374)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

An interval NLPV parity equations approach for fault detection and isolation of a wind farm

  • Blesa, Joaquim
  • Jiménez, Pedro
  • Rotondo, Damiano
  • Nejjari, Fatiha
  • Puig, Vicenç
In this paper, the problem of fault diagnosis of a wind farm is addressed using interval nonlinear parameter-varying (NLPV) parity equations. Fault detection is based on the use of parity equations assuming unknown but bounded description of the noise and modeling errors. The fault detection test is based on checking the consistency between the measurements and the model, by finding if the formers are inside the interval prediction bounds. The fault isolation algorithm is based on analyzing the observed fault signatures online and matching them with the theoretical ones obtained using structural analysis. Finally, the proposed approach is tested using the wind farm benchmark proposed in the context of the wind farm faultdetection-and-isolation/fault-tolerant-control competition., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428), by AGAUR through the contracts FI-DGR 2013 (ref. 2013FIB00218) and FI-DGR 2014 (ref. 2014FI B1 00172) and by the DGR of Generalitat de Catalunya (SAC group Ref. 2014/SGR/374)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Automated generation and comparison of Takagi-Sugeno and polytopic quasi-LPV models

  • Rotondo, Damiano
  • Puig, Vicenç
  • Nejjari, Fatiha
  • Witczak, Marcin
In the last decades, gain-scheduling control techniques have consolidated as an efficient answer to analysis and synthesis problems for non-linear systems. Among the approaches proposed in the literature, the linear parameter varying (LPV) and Takagi-Sugeno (TS) paradigms have proved to be successful in dealing with the different trials that the analyzer, or the designer, of a gain-scheduled control system has to face. Despite the strong similarities between the two paradigms, research on LPV and TS systems has been performed in an independent way and some results that could be useful for both paradigms were obtained only for one of them. However, in recent works, some clues that there is a very close connection between LPV and TS worlds have been presented. The present paper openly addresses the presence of strong analogies between LPV and TS models, in an attempt to establish a bridge between these two worlds, so far considered different. In particular, this paper addresses the modeling problem, presenting two methods for the automated generation of LPV and TS systems, and introducing some measures in order to compare the obtained models. A mathematical example is used to illustrate the proposed methods., This work has been funded by the Spanish Ministry of Science and Technology through the projects CICYT SHERECS (Ref. DPI2011-26243) and CICYT ECOCIS (Ref. DPI2013-48243-C2-1-R), by the European Commission through contract i-Sense FP7-ICT-2009-6-270428, by UPC through the grant FPI-UPC E-01104, by AGAUR through the contracts FI-DGR 2013 (Ref. 2013FIB00218) and FI-DGR 2014 (Ref. 2014FI_B1 00172), and by the DGR of Generalitat de Catalunya (SAC group Ref. 2014/SGR/374). The work was also supported by the National Science Centre in Poland under the grant 2013/11/B/ST7/01110., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Set-membership parity space approach for fault detection in linear uncertain dynamic systems

  • Blesa, Joaquim
  • Puig, Vicenç
  • Saludes, Jordi
  • Fernández Cantí, Rosa M.
Special Issue: Set-Membership Methods Applied to FDI and FTC., In this paper, a set-membership parity space approach for linear uncertain dynamic systems is proposed. First, a set of parity relations derived from the parity space approach is obtained by means of a transformation derived from the system characteristic polynomial. As a result of this transformation, parity relations can be expressed in regressor form. On the one hand, this facilitates the parameter estimation of those relations using a zonotopic set-membership algorithm. On the other hand, fault detection is then based on checking, at every sample time, the non-existence of a parameter value in the parameter uncertainty set such that the model is consistent with all the system measurements. The proposed approach is applied to two examples: a first illustrative case study based on a two-tank system and a more realistic case study based on the wind turbine fault detection and isolation benchmark in order to evaluate its effectiveness., This work has been partially funded by the grant CICYT SHERECS DPI-2011-26243 of Spanish Ministry of Education and by the European contract i-Sense (ref FP7-ICT-2009-6-270428), Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Set-membership identification and fault detection using a Bayesian framework

  • Fernández Cantí, Rosa M.
  • Blesa, Joaquim
  • Puig, Vicenç
  • Tornil-Sin, Sebastian
This paper deals with the problem of set-membership identification and fault detection using a Bayesian framework. The paper presents how the set-membership model estimation problem can be reformulated from the Bayesian viewpoint in order to, first, determine the feasible parameter set in the identification stage and, second, check the consistency between the measurement data and the model in the fault-detection stage. The paper shows that, assuming uniform distributed measurement noise and uniform model prior probability distributions, the Bayesian approach leads to the same feasible parameter set than the well-known set-membership technique based on approximating the feasible parameter set using sets. Additionally, it can deal with models that are nonlinear in the parameters. The single-output and multiple-output cases are addressed as well. The procedure and results are illustrated by means of the application to a quadruple-tank process., This work has been partially grant-funded by CICYT SHERECS DPI-2011-26243 and CICYT WATMAN DPI-2009-13744 of the Spanish Ministry of Education and by i-Sense grant FP7-ICT-2009-6-270428 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Set-theoretic methods in robust detection and isolation of sensor faults

  • Xu, Feng
  • Puig, Vicenç
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
  • Stoican, Florin
This paper proposes a sensorfault detection and isolation (FDI) approach based on interval observers and invariant sets. In fault detection (FD), both interval observer-based and invariant set-based mechanisms are used to provide real-time fault alarms. In fault isolation (FI), the proposed approach also uses these two different mechanisms. The former, based on interval observers, aims to isolate faults during the transient-state operation induced by faults. If the former does not succeed, the latter, based on both interval observers and invariant sets, is started to guarantee FI after the system enters into steady state. Besides, a collection of invariant set-based FDI conditions are established by using all available system-operating information provided by all interval observers. In order to reduce computational complexity, a method to remove all available but redundant/unnecessary system-operating information is incorporated into this approach. If the considered faults satisfy the proposed FDI conditions, it can be guaranteed that they are detectable and isolable after their occurrences. This paper concludes with a case study based on a subsystem of a wind turbine benchmark, which can illustrate the effectiveness of this FDI technique., The work has been partially funded by the DGR of Generalitat de Catalunya (SAC group Ref.2009/SGR/1491), European Commission through contract i-Sense (FP7-ICT-2009-6-270428), China Scholarship Council (File No.2011629170), and the Sectoral Operational Programme Human Resources Development 2007-2013 of the Ministry of European Funds through the Financial Agreement POSDRU/159/1.5/S/132395., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Non-linear set-membership identification approach based on the Bayesian framework

  • Fernández Cantí, Rosa M.
  • Tornil-Sin, Sebastian
  • Blesa, Joaquim
  • Puig, Vicenç
This study deals with the problem of set-membership identification of non-linear-in-the-parameters models. To solve this problem, this study illustrates how the Bayesian approach can be used to determine the feasible parameter set (FPS) by assuming uniform distributed estimation error and flat model prior probability distributions. The key point of the methodology is the interval evaluation of the likelihood function and the result is a set of boxes with associated credibility indices. For each box, the credibility index is in the interval (0, 1] and gives information about the amount of consistent models inside the box. The union of the boxes with credibility value equal to one provides an inner approximation of the FPS, whereas the union of all boxes provides an outer estimation. The boxes with credibility value smaller than one are located around the boundary of the FPS and their credibility index can be used to iteratively refine the inner and outer approximations up to a desired precision. The main issues and performance of the developed algorithms are discussed and illustrated by means of examples., This work has been partially grant-funded by CICYT SHERECS DPI-2011-26243 and CICYT ECOCIS (Ref.DPI2013-48243-C2-1-R) DPI-2009-13744 of the Spanish Ministry of Education and by i-Sense grant FP7-ICT-2009-6-270428 of the European Commission., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Automated generation and comparison of Takagi–Sugeno and polytopic quasi-LPV models

  • Rotondo, Damiano|||0000-0002-8855-5582
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Witczak, Marcin
In the last decades, gain-scheduling control techniques have consolidated as an efficient answer to analysis and synthesis problems for non-linear systems. Among the approaches proposed in the literature, the linear parameter varying (LPV) and Takagi–Sugeno (TS) paradigms have proved to be successful in dealing with the different trials that the analyzer, or the designer, of a gain-scheduled control system has to face. Despite the strong similarities between the two paradigms, research on LPV and TS systems has been performed in an independent way and some results that could be useful for both paradigms were obtained only for one of them. However, in recent works, some clues that there is a very close connection between LPV and TS worlds have been presented. The present paper openly addresses the presence of strong analogies between LPV and TS models, in an attempt to establish a bridge between these two worlds, so far considered different. In particular, this paper addresses the modeling problem, presenting two methods for the automated generation of LPV and TS systems, and introducing some measures in order to compare the obtained models. A mathematical example is used to illustrate the proposed methods., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Garza Castañón, Luís Eduardo
  • Rosich, Albert
This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Application of predictive control strategies to the management of complex networks in the urban water cycle

  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Cembrano Gennari, Gabriela|||0000-0003-1436-6022
  • Quevedo Casín, Joseba Jokin|||0000-0002-7827-2896
The management of the urban water cycle (UWC) is a subject of increasing interest because of its social, economic, and environmental impact. The most important issues include the sustainable use of limited resources and the reliability of service to consumers with adequate quality and pressure levels, as well as the urban drainage management to prevent flooding and polluting discharges to the environment., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Actuator-fault detection and isolation based on set-theoretic approaches

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an actuator-fault detection and isolation (FDI) approach is proposed. The FDI approach is based on a bank of interval observers, each of which is designed to match a healthy or faulty system mode. To ensure reliable FDI for all considered actuator faults, a collection of invariant set-based FDI conditions are established for the proposed technique. Under these guaranteed FDI conditions, all the considered faults can be detected and isolated during the transition induced by fault occurrences. Comparing with the existing set-based FDI approaches, the advantage of the proposed technique consists in that it combines the advantages of interval observers in the transient-state functioning and the advantages of invariant sets in the steady-state functioning. This paper is completed with the study of a continuous stirred-tank reactor (CSTR), which illustrates the effectiveness of the proposed method. (C) 2014 Elsevier Ltd. All rights reserved.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Non-linear set-membership identification approach based on the Bayesian framework

  • Fernández Canti, Rosa M.|||0000-0002-9381-6601
  • Tornil Sin, Sebastián|||0000-0003-1799-2192
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
This study deals with the problem of set-membership identification of non-linear-in-the-parameters models. To solve this problem, this study illustrates how the Bayesian approach can be used to determine the feasible parameter set (FPS) by assuming uniform distributed estimation error and flat model prior probability distributions. The key point of the methodology is the interval evaluation of the likelihood function and the result is a set of boxes with associated credibility indices. For each box, the credibility index is in the interval (0, 1] and gives information about the amount of consistent models inside the box. The union of the boxes with credibility value equal to one provides an inner approximation of the FPS, whereas the union of all boxes provides an outer estimation. The boxes with credibility value smaller than one are located around the boundary of the FPS and their credibility index can be used to iteratively refine the inner and outer approximations up to a desired precision. The main issues and performance of the developed algorithms are discussed and illustrated by means of examples., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Set-theoretic methods in robust detection and isolation of sensor faults

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Olaru, Sorin
  • Stoican, Florin
This paper proposes a sensor-fault detection and isolation (FDI) approach based on interval observers and invariant sets. In fault detection (FD), both interval observer-based and invariant set-based mechanisms are used to provide real-time fault alarms. In fault isolation (FI), the proposed approach also uses these two different mechanisms. The former, based on interval observers, aims to isolate faults during the transient-state operation induced by faults. If the former does not succeed, the latter, based on both interval observers and invariant sets, is started to guarantee FI after the system enters into steady state. Besides, a collection of invariant set-based FDI conditions are established by using all available system-operating information provided by all interval observers. In order to reduce computational complexity, a method to remove all available but redundant/unnecessary system-operating information is incorporated into this approach. If the considered faults satisfy the proposed FDI conditions, it can be guaranteed that they are detectable and isolable after their occurrences. This paper concludes with a case study based on a subsystem of a wind turbine benchmark, which can illustrate the effectiveness of this FDI technique.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Set-membership parity space approach for fault detection in linear uncertain dynamic systems

  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Saludes Closa, Jordi|||0000-0002-6666-1982
  • Fernández Canti, Rosa M.|||0000-0002-9381-6601
In this paper, a set-membership parity space approach for linear uncertain dynamic systems is proposed. First, a set of parity relations derived from the parity space approach is obtained by means of a transformation derived from the system characteristic polynomial. As a result of this transformation, parity relations can be expressed in regressor form. On the one hand, this facilitates the parameter estimation of those relations using a zonotopic set-membership algorithm. On the other hand, fault detection is then based on checking, at every sample time, the non-existence of a parameter value in the parameter uncertainty set such that the model is consistent with all the system measurements. The proposed approach is applied to two examples: a first illustrative case study based on a two-tank system and a more realistic case study based on the wind turbine fault detection and isolation benchmark in order to evaluate its effectiveness, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Robust identification and fault diagnosis based on uncertain multiple input-multiple output linear parameter varying parity equations and zonotopes

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Set-membership identification and fault detection using a Bayesian framework

  • Fernández Canti, Rosa M.|||0000-0002-9381-6601
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Tornil Sin, Sebastián|||0000-0003-1799-2192
This paper deals with the problem of set-membership identification and fault detection using a Bayesian framework. The paper presents how the set-membership model estimation problem can be reformulated from the Bayesian viewpoint in order to, first, determine the feasible parameter set in the identification stage and, second, check the consistency between the measurement data and the model in the fault-detection stage. The paper shows that, assuming uniform distributed measurement noise and uniform model prior probability distributions, the Bayesian approach leads to the same feasible parameter set than the well-known set-membership technique based on approximating the feasible parameter set using sets. Additionally, it can deal with models that are nonlinear in the parameters. The single-output and multiple-output cases are addressed as well. The procedure and results are illustrated by means of the application to a quadruple-tank process., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Combining learning in model space fault diagnosis with data validation/reconstruction: Application to the Barcelona water network

  • Quevedo Casín, Joseba Jokin|||0000-0002-7827-2896
  • Chen, Heran
  • Cugueró Escofet, Miquel Àngel|||0000-0001-9525-1790
  • Tino, Peter
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • García Valverde, Diego
  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Yao, Xin
In this paper, an integrated data validation/reconstruction and fault diagnosis approach is proposed for critical infrastructure systems. The proposed methodology is implemented in a two-stage approach. In the first stage, sensor communication faults are detected and corrected, in order to facilitate a reliable dataset to perform system fault diagnosis in the second stage. On the one hand, sensor validation and reconstruction are based on the combined use of spatial and time series models. Spatial models take advantage of the (mass-balance) relation between different variables in the system, whilst time series models take advantage of the temporal redundancy of the measured variables by means of Holt-Winters time series models. On the other hand, fault diagnosis is based on the learning-in-model-space approach that is implemented by fitting a series of models using a series of signal segments selected with a sliding window. In this way, each signal segment can be represented by one model. To rigorously measure the ‘distance’ between models, the distance in the model space is defined. The deterministic reservoir computing approach is used to approximate a model with the input–output dynamics that exploits spatial–temporal correlations existing in the original data. Finally, the proposed approach is successfully applied to the Barcelona water network., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Adaptive threshold generation in robust fault detection using interval models: Time-domain and frequency-domain approaches

  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Montes de Oca Armeaga, Saul
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
In this paper, robust fault detection is addressed on the basis of evaluating the residual energy that it is compared against worst-case value (threshold) generated considering parametric modeling uncertainty using interval models. The evaluation of the residual/threshold energy can be performed either in the time or frequency domain. This paper proposes methods to compute such energy in the two domains. The first method generates the adaptive threshold in the time domain through determining the worst-case time evolution of the residual energy using a zonotope-based algorithm. The second method evaluates the worstcase energy evolution in the frequency domain using the Kharitonov polynomials. Results obtained using both approaches are related through the Parseval’s theorem. Finally, two application examples (a smart servoactuator and a two DOFs helicopter) will be used to assess the validity of the proposed approaches and compare the results obtained.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

A virtual actuator and sensor approach for fault tolerant control of LPV systems

  • Rotondo, Damiano|||0000-0002-8855-5582
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
In this paper, a fault tolerant control (FTC) strategy using virtual actuators and sensors for linear parameter varying (LPV) systems is proposed. The main idea of this FTC method, initially developed for LTI systems, is to reconfigure the control loop such that the nominal controller could still be used without need of retuning it. The plant with the faulty actuator/sensor is modified adding the virtual actuator/sensor block that masks the actuator/sensor fault. The suggested technique is an active FTC strategy that reconfigures the virtual actuator/sensor on-line taking into account faults and operating point changes. The stability of the reconfigured control loop is guaranteed if the faulty plant is stabilizable/detectable. The LPV virtual actuator/sensor is designed using polytopic LPV techniques and linear matrix inequalities (LMIs). A two-tank system simulator is used to assess the performance of the proposed method. In particular, it is shown that the application of the proposed technique results in an improvement, in terms of performance, with respect to the LTI counterpart, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Robust quasi-LPV model reference FTC of a quadrotor UAV subject to actuator faults

  • Rotondo, Damiano|||0000-0002-8855-5582
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
A solution for fault tolerant control (FTC) of a quadrotor unmanned aerial vehicle (UAV) is proposed. It relies on model reference-based control, where a reference model generates the desired trajectory. Depending on the type of reference model used for generating the reference trajectory, and on the assumptions about the availability and uncertainty of fault estimation, different error models are obtained. These error models are suitable for passive FTC, active FTC and hybrid FTC, the latter being able to merge the benefits of active and passive FTC while reducing their respective drawbacks. The controller is generated using results from the robust linear parameter varying (LPV) polytopic framework, where the vector of varying parameters is used to schedule between uncertain linear time invariant (LTI) systems. The design procedure relies on solving a set of linear matrix inequalities (LMIs) in order to achieve regional pole placement and H8 norm bounding constraints. Simulation results are used to compare the different FTC strategies., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Quasi-LPV modeling, identification and control of a twin rotor MIMO system

  • Rotondo, Damiano|||0000-0002-8855-5582
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
This paper describes the quasi-linear parameter varying (quasi-LPV) modeling, identification and control of a Twin Rotor MIMO System (TRMS). The non-linear model of the TRMS is transformed into a quasi-LPV system and approximated in a polytopic way. The unknown model parameters have been calibrated by means of the non-linear least squares identification approach and validated against real data. Finally, an LPV state observer and state-feedback controller have been designed using an LPV pole placement method based on LMI regions. The effectiveness and performance of the proposed control approach have been proved both in simulation and on the real set-up., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

A fault-hiding approach for the switching quasi-LPV fault-tolerant control of a four-wheeled omnidirectional mobile robot

  • Rotondo, Damiano|||0000-0002-8855-5582
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Romera Formiguera, Juli
This paper proposes a reference model approach for the trajectory tracking of a four-wheeled omnidirectional mobile robot. In particular, the error model is brought to a quasi-linear-parameter-varying (LPV) form suitable for designing an error-feedback controller. It is shown that, if polytopic techniques are used to reduce the number of constraints from infinite to finite, a solution within the standard LPV framework could not exist due to a singularity that appears in the possible values of the input matrix. Adding a switching component to the controller allows solving this problem. Moreover, a switching LPV virtual actuator is added to the control loop in order to obtain fault tolerance within the fault-hiding paradigm, keeping the stability and some desired performances under the effect of actuator faults without the need of retuning the nominal controller. The effectiveness of the proposed approach is shown and proved through simulation and experimental results., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Robust identification and fault diagnosis based on uncertain multiple input-multiple output linear parameter varying parity equations and zonotopes

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Adaptive threshold generation in robust fault detection using interval models: Time-domain and frequency-domain approaches

  • Puig Cayuela, Vicenç
  • Montes de Oca Armeaga, Saul
  • Blesa Izquierdo, Joaquim
In this paper, robust fault detection is addressed on the basis of evaluating the residual energy that it is compared against worst-case value (threshold) generated considering parametric modeling uncertainty using interval models. The evaluation of the residual/threshold energy can be performed either in the time or frequency domain. This paper proposes methods to compute such energy in the two domains. The first method generates the adaptive threshold in the time domain through determining the worst-case time evolution of the residual energy using a zonotope-based algorithm. The second method evaluates the worstcase energy evolution in the frequency domain using the Kharitonov polynomials. Results obtained using both approaches are related through the Parseval’s theorem. Finally, two application examples (a smart servoactuator and a two DOFs helicopter) will be used to assess the validity of the proposed approaches and compare the results obtained., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Set-theoretic methods in robust detection and isolation of sensor faults

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
  • Stoican, Florin
This paper proposes a sensor-fault detection and isolation (FDI) approach based on interval observers and invariant sets. In fault detection (FD), both interval observer-based and invariant set-based mechanisms are used to provide real-time fault alarms. In fault isolation (FI), the proposed approach also uses these two different mechanisms. The former, based on interval observers, aims to isolate faults during the transient-state operation induced by faults. If the former does not succeed, the latter, based on both interval observers and invariant sets, is started to guarantee FI after the system enters into steady state. Besides, a collection of invariant set-based FDI conditions are established by using all available system-operating information provided by all interval observers. In order to reduce computational complexity, a method to remove all available but redundant/unnecessary system-operating information is incorporated into this approach. If the considered faults satisfy the proposed FDI conditions, it can be guaranteed that they are detectable and isolable after their occurrences. This paper concludes with a case study based on a subsystem of a wind turbine benchmark, which can illustrate the effectiveness of this FDI technique., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Quasi-LPV modeling, identification and control of a twin rotor MIMO system

  • Rotondo, Damiano
  • Nejjari Akhi-Elarab, Fatiha
  • Puig Cayuela, Vicenç
This paper describes the quasi-linear parameter varying (quasi-LPV) modeling, identification and control of a Twin Rotor MIMO System (TRMS). The non-linear model of the TRMS is transformed into a quasi-LPV system and approximated in a polytopic way. The unknown model parameters have been calibrated by means of the non-linear least squares identification approach and validated against real data. Finally, an LPV state observer and state-feedback controller have been designed using an LPV pole placement method based on LMI regions. The effectiveness and performance of the proposed control approach have been proved both in simulation and on the real set-up., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A virtual actuator and sensor approach for fault tolerant control of LPV systems

  • Rotondo, Damiano
  • Nejjari Akhi-Elarab, Fatiha
  • Puig Cayuela, Vicenç
In this paper, a fault tolerant control (FTC) strategy using virtual actuators and sensors for linear parameter varying (LPV) systems is proposed. The main idea of this FTC method, initially developed for LTI systems, is to reconfigure the control loop such that the nominal controller could still be used without need of retuning it. The plant with the faulty actuator/sensor is modified adding the virtual actuator/sensor block that masks the actuator/sensor fault. The suggested technique is an active FTC strategy that reconfigures the virtual actuator/sensor on-line taking into account faults and operating point changes. The stability of the reconfigured control loop is guaranteed if the faulty plant is stabilizable/detectable. The LPV virtual actuator/sensor is designed using polytopic LPV techniques and linear matrix inequalities (LMIs). A two-tank system simulator is used to assess the performance of the proposed method. In particular, it is shown that the application of the proposed technique results in an improvement, in terms of performance, with respect to the LTI counterpart, Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Actuator-fault detection and isolation based on set-theoretic approaches

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an actuator-fault detection and isolation (FDI) approach is proposed. The FDI approach is based on a bank of interval observers, each of which is designed to match a healthy or faulty system mode. To ensure reliable FDI for all considered actuator faults, a collection of invariant set-based FDI conditions are established for the proposed technique. Under these guaranteed FDI conditions, all the considered faults can be detected and isolated during the transition induced by fault occurrences. Comparing with the existing set-based FDI approaches, the advantage of the proposed technique consists in that it combines the advantages of interval observers in the transient-state functioning and the advantages of invariant sets in the steady-state functioning. This paper is completed with the study of a continuous stirred-tank reactor (CSTR), which illustrates the effectiveness of the proposed method. (C) 2014 Elsevier Ltd. All rights reserved., Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Set-membership identification and fault detection using a Bayesian framework

  • Fernández Canti, Rosa M.
  • Blesa Izquierdo, Joaquim
  • Puig Cayuela, Vicenç
  • Tornil Sin, Sebastián
This paper deals with the problem of set-membership identification and fault detection using a Bayesian framework. The paper presents how the set-membership model estimation problem can be reformulated from the Bayesian viewpoint in order to, first, determine the feasible parameter set in the identification stage and, second, check the consistency between the measurement data and the model in the fault-detection stage. The paper shows that, assuming uniform distributed measurement noise and uniform model prior probability distributions, the Bayesian approach leads to the same feasible parameter set than the well-known set-membership technique based on approximating the feasible parameter set using sets. Additionally, it can deal with models that are nonlinear in the parameters. The single-output and multiple-output cases are addressed as well. The procedure and results are illustrated by means of the application to a quadruple-tank process., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig Cayuela, Vicenç
  • Garza Castañón, Luís Eduardo
  • Rosich, Albert
This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Automated generation and comparison of Takagi–Sugeno and polytopic quasi-LPV models

  • Rotondo, Damiano
  • Puig Cayuela, Vicenç
  • Nejjari Akhi-Elarab, Fatiha
  • Witczak, Marcin
In the last decades, gain-scheduling control techniques have consolidated as an efficient answer to analysis and synthesis problems for non-linear systems. Among the approaches proposed in the literature, the linear parameter varying (LPV) and Takagi–Sugeno (TS) paradigms have proved to be successful in dealing with the different trials that the analyzer, or the designer, of a gain-scheduled control system has to face. Despite the strong similarities between the two paradigms, research on LPV and TS systems has been performed in an independent way and some results that could be useful for both paradigms were obtained only for one of them. However, in recent works, some clues that there is a very close connection between LPV and TS worlds have been presented. The present paper openly addresses the presence of strong analogies between LPV and TS models, in an attempt to establish a bridge between these two worlds, so far considered different. In particular, this paper addresses the modeling problem, presenting two methods for the automated generation of LPV and TS systems, and introducing some measures in order to compare the obtained models. A mathematical example is used to illustrate the proposed methods., Peer Reviewed, Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Combining learning in model space fault diagnosis with data validation/reconstruction: Application to the Barcelona water network

  • Quevedo Casín, Joseba Jokin
  • Chen, Heran
  • Cugueró Escofet, Miquel Àngel
  • Tino, Peter
  • Puig Cayuela, Vicenç
  • García Valverde, Diego
  • Sarrate Estruch, Ramon
  • Yao, Xin
In this paper, an integrated data validation/reconstruction and fault diagnosis approach is proposed for critical infrastructure systems. The proposed methodology is implemented in a two-stage approach. In the first stage, sensor communication faults are detected and corrected, in order to facilitate a reliable dataset to perform system fault diagnosis in the second stage. On the one hand, sensor validation and reconstruction are based on the combined use of spatial and time series models. Spatial models take advantage of the (mass-balance) relation between different variables in the system, whilst time series models take advantage of the temporal redundancy of the measured variables by means of Holt-Winters time series models. On the other hand, fault diagnosis is based on the learning-in-model-space approach that is implemented by fitting a series of models using a series of signal segments selected with a sliding window. In this way, each signal segment can be represented by one model. To rigorously measure the ‘distance’ between models, the distance in the model space is defined. The deterministic reservoir computing approach is used to approximate a model with the input–output dynamics that exploits spatial–temporal correlations existing in the original data. Finally, the proposed approach is successfully applied to the Barcelona water network., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Non-linear set-membership identification approach based on the Bayesian framework

  • Fernández Canti, Rosa M.
  • Tornil Sin, Sebastián
  • Blesa Izquierdo, Joaquim
  • Puig Cayuela, Vicenç
This study deals with the problem of set-membership identification of non-linear-in-the-parameters models. To solve this problem, this study illustrates how the Bayesian approach can be used to determine the feasible parameter set (FPS) by assuming uniform distributed estimation error and flat model prior probability distributions. The key point of the methodology is the interval evaluation of the likelihood function and the result is a set of boxes with associated credibility indices. For each box, the credibility index is in the interval (0, 1] and gives information about the amount of consistent models inside the box. The union of the boxes with credibility value equal to one provides an inner approximation of the FPS, whereas the union of all boxes provides an outer estimation. The boxes with credibility value smaller than one are located around the boundary of the FPS and their credibility index can be used to iteratively refine the inner and outer approximations up to a desired precision. The main issues and performance of the developed algorithms are discussed and illustrated by means of examples., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Set-membership parity space approach for fault detection in linear uncertain dynamic systems

  • Blesa Izquierdo, Joaquim
  • Puig Cayuela, Vicenç
  • Saludes Closa, Jordi
  • Fernández Canti, Rosa M.
In this paper, a set-membership parity space approach for linear uncertain dynamic systems is proposed. First, a set of parity relations derived from the parity space approach is obtained by means of a transformation derived from the system characteristic polynomial. As a result of this transformation, parity relations can be expressed in regressor form. On the one hand, this facilitates the parameter estimation of those relations using a zonotopic set-membership algorithm. On the other hand, fault detection is then based on checking, at every sample time, the non-existence of a parameter value in the parameter uncertainty set such that the model is consistent with all the system measurements. The proposed approach is applied to two examples: a first illustrative case study based on a two-tank system and a more realistic case study based on the wind turbine fault detection and isolation benchmark in order to evaluate its effectiveness, Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Application of predictive control strategies to the management of complex networks in the urban water cycle

  • Ocampo-Martínez, Carlos
  • Puig Cayuela, Vicenç
  • Cembrano Gennari, Gabriela
  • Quevedo Casín, Joseba Jokin
The management of the urban water cycle (UWC) is a subject of increasing interest because of its social, economic, and environmental impact. The most important issues include the sustainable use of limited resources and the reliability of service to consumers with adequate quality and pressure levels, as well as the urban drainage management to prevent flooding and polluting discharges to the environment., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Robust quasi-LPV model reference FTC of a quadrotor UAV subject to actuator faults

  • Rotondo, Damiano
  • Nejjari Akhi-Elarab, Fatiha
  • Puig Cayuela, Vicenç
A solution for fault tolerant control (FTC) of a quadrotor unmanned aerial vehicle (UAV) is proposed. It relies on model reference-based control, where a reference model generates the desired trajectory. Depending on the type of reference model used for generating the reference trajectory, and on the assumptions about the availability and uncertainty of fault estimation, different error models are obtained. These error models are suitable for passive FTC, active FTC and hybrid FTC, the latter being able to merge the benefits of active and passive FTC while reducing their respective drawbacks. The controller is generated using results from the robust linear parameter varying (LPV) polytopic framework, where the vector of varying parameters is used to schedule between uncertain linear time invariant (LTI) systems. The design procedure relies on solving a set of linear matrix inequalities (LMIs) in order to achieve regional pole placement and H8 norm bounding constraints. Simulation results are used to compare the different FTC strategies., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A fault-hiding approach for the switching quasi-LPV fault-tolerant control of a four-wheeled omnidirectional mobile robot

  • Rotondo, Damiano
  • Puig Cayuela, Vicenç
  • Nejjari Akhi-Elarab, Fatiha
  • Romera Formiguera, Juli
This paper proposes a reference model approach for the trajectory tracking of a four-wheeled omnidirectional mobile robot. In particular, the error model is brought to a quasi-linear-parameter-varying (LPV) form suitable for designing an error-feedback controller. It is shown that, if polytopic techniques are used to reduce the number of constraints from infinite to finite, a solution within the standard LPV framework could not exist due to a singularity that appears in the possible values of the input matrix. Adding a switching component to the controller allows solving this problem. Moreover, a switching LPV virtual actuator is added to the control loop in order to obtain fault tolerance within the fault-hiding paradigm, keeping the stability and some desired performances under the effect of actuator faults without the need of retuning the nominal controller. The effectiveness of the proposed approach is shown and proved through simulation and experimental results., Peer Reviewed, Postprint (author’s final draft)