Publicación Contribución de congreso (ConferenceOutput)

Actuator-fault detection and isolation based on interval observers and invariant sets

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
Trabajo presentado a la 52nd CDC celebrada en Florencia del 10 al 13 de diciembre de 2013., This paper proposes an interval observer-based actuator fault detection and isolation (FDI) approach. An interval observer matching the healthy system mode is designed to monitor the system. When the system is in different modes, state or output interval vectors predicted by the interval observer manifest different dynamical behaviors. To guarantee reliable FDI, a collection of invariant set-based FDI conditions are established. Under these conditions, actuator faults can be accurately detected and isolated during the transition between different modes. At the end, the effectiveness of this proposed approach is presented by using a numerical example., The work of F. Xu, V. Puig and C. Ocampo-Martinez has been supported by Spanish research project WATMAN (DPI2009-13744) of the Science and Technology Ministry, by the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), by European Comission through contract i-Sense (FP7-ICT-2009-6-270428), and by China Scholarship Council (File No.2011629170). Besi, Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Adaptive threshold generation in robust fault detection using interval models: time-domain and frequency-domain approaches

  • Puig, Vicenç
  • Montes de Oca, Saúl
  • Blesa, Joaquim
In this paper, robust fault detection is addressed on the basis of evaluating the residual energy that it is compared against worst-case value (threshold) generated considering parametric modeling uncertainty using interval models. The evaluation of the residual/threshold energy can be performed either in the time or frequency domain. This paper proposes methods to compute such energy in the two domains. The first method generates the adaptive threshold in the time domain through determining the worst-case time evolution of the residual energy using a zonotope-based algorithm. The second method evaluates the worst-case energy evolution in the frequency domain using the Kharitonov polynomials. Results obtained using both approaches are related through the Parseval's theorem. Finally, two application examples (a smart servoactuator and a two DOFs helicopter) will be used to assess the validity of the proposed approaches and compare the results obtained. Copyright © 2012 John Wiley & Sons, Ltd., Funded by: CICYT SHERECS. Grant Number: DPI2011- 26243 and European Commission. Grant Number: i-Sense FP7-ICT-2009-6-270428., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

A service reliability model predictive control with dynamic safety stocks and actuators health monitoring for drinking water networks

  • Grosso, J. M.
  • Ocampo-Martínez, Carlos
  • Puig, Vicenç
Trabajo presentado al 51st CDC celebrado en Maui (Hawai) del 10 al 13 de diciembre de 2012., This paper presents a model predictive control strategy to assure reliability in drinking water networks given a customer service level and a forecasting demand. The underlying idea concerns a two-layer hierarchical control structure. The upper layer performs a local steady-state optimization to set up an inventory replenishment policy based on dynamic safety stocks for each tank in the network. At the same stage, actuators health is revised to set up their next maximum allowable degradation in order to efficiently distribute overall control effort and guarantee system availability. In the lower layer, a model predictive control algorithm is implemented to compute optimal control set-points to minimize a multiobjective cost function. Simulation results in the Barcelona Drinking Water Network have shown the effectiveness of the dynamic safety stocks allocation and the actuators health monitoring to assure service reliability and optimizing network operational costs., This work has been supported by Spanish research projects WATMAN (CICYT DPI2009-13744) and SHERECS (CYCYT DPI2011-26243) of the Science and Technology Ministry, the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), and by European Comission through contract i-Sense (FP7-ICT-2009-6-270428), Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A virtual actuator and sensor approach for fault tolerant control of LPV systems

  • Rotondo, Damiano
  • Nejjari, Fatiha
  • Puig, Vicenç
In this paper, a fault tolerant control (FTC) strategy using virtual actuators and sensors for linear parameter varying (LPV) systems is proposed. The main idea of this FTC method, initially developed for LTI systems, is to reconfigure the control loop such that the nominal controller could still be used without need of retuning it. The plant with the faulty actuator/sensor is modified adding the virtual actuator/sensor block that masks the actuator/sensor fault. The suggested technique is an active FTC strategy that reconfigures the virtual actuator/sensor on-line taking into account faults and operating point changes. The stability of the reconfigured control loop is guaranteed if the faulty plant is stabilizable/detectable. The LPV virtual actuator/sensor is designed using polytopic LPV techniques and linear matrix inequalities (LMIs). A two-tank system simulator is used to assess the performance of the proposed method. In particular, it is shown that the application of the proposed technique results in an improvement, in terms of performance, with respect to the LTI counterpart. © 2014 Elsevier Ltd., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428), by UPC through the grant FPI-UPC E-01104 and by AGAUR through thecontract FI-DGR 2013 (ref. 2013FIB00218)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Combining learning in model space fault diagnosis with data validation/reconstruction: Application to the Barcelona water network

  • Quevedo, Joseba
  • Chen, Hung
  • Cugueró-Escofet, Miquel Àngel
  • Puig, Vicenç
  • Sarrate, Ramon
In this paper, an integrated data validation/reconstruction and fault diagnosis approach is proposed for critical infrastructure systems. The proposed methodology is implemented in a two-stage approach. In the first stage, sensor communication faults are detected and corrected, in order to facilitate a reliable dataset to perform system fault diagnosis in the second stage. On the one hand, sensor validation and reconstruction are based on the combined use of spatial and time series models. Spatial models take advantage of the (mass-balance) relation between different variables in the system, whilst time series models take advantage of the temporal redundancy of the measured variables by means of Holt-Winters time series models. On the other hand, fault diagnosis is based on the learning-in-model-space approach that is implemented by fitting a series of models using a series of signal segments selected with a sliding window. In this way, each signal segment can be represented by one model. To rigorously measure the 'distance' between models, the distance in the model space is defined. The deterministic reservoir computing approach is used to approximate a model with the input-output dynamics that exploits spatial-temporal correlations existing in the original data. Finally, the proposed approach is successfully applied to the Barcelona water network. © 2014 Elsevier Ltd., This work is supported by the European Union Seventh Framework Programme, in the framework of the iSense project,under Grant agreement no. INSFO-ICT-270428., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig, Vicenç
  • Garza-Castañón, Luis E.
  • Rosich, Albert
This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license., This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach. © 2013 by the authors; licensee MDPI, Basel, Switzerland., This work is supported by the Research Chair in Supervision and Advanced Control of Tecnológico de Monterrey, Campus Monterrey and by a CONACYT studentship. This work has been partially grant-funded by CICYTSHERECSDPI-2011-26243 and CICYT WATMANDPI-2009-13744 of the Spanish Ministry of Education, by iSense grant FP7-ICT-2009-6-270428 and by EFFINETgrant FP7-ICT-2012-318556 of the European Commission. This work is also partially founded by the Fond National de la Recherche, Luxembourg (CO11/IS/1206050)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Model-based optimal sensor placement approaches to fuel cell stack system fault diagnosis

  • Sarrate, Ramon
  • Nejjari, Fatiha
  • Rosich, Albert
Trabajo presentado al 8th IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes celebrado en México del 29 al 31 de agosto de 2012., The problem of optimal sensor placement for FDI consists in determining the set of sensors that minimizes a pre-defined cost function satisfying at the same time a pre-established set of FDI specifications for a given set of faults. This paper recalls three model-based optimal sensor location approaches: an Incremental search, a Heuristic search and a Binary Integer Linear Programming (BILP) formulation. The main contribution of this paper is a comparative study that addresses efficiency, flexibility and other issues. The performance of the approaches is demonstrated by an application to a fuel cell stack system., This work has been funded by the Spanish Ministry of Science and Technology through the CICYT project WATMAN (ref. DPI2009-13744), by the Spanish Ministry of Economy and Competitiveness through the CICYT project SHERECS (ref. DPI2011-26243), and by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault detection and isolation based on structural models

  • Rosich, Albert
Trabajo presentado al 8th IFAC Symposium on SAFEPROCESS celebrado en Mexico del 29 al 31 de agosto de 2012., This paper presents a new algorithm for solving the sensor placement problem in order to achieve the required fault detectability and isolability. The method is based on structural models, which means that non-linear differential systems can be efficiently handled. The developed algorithm does not need to compute any residual since it is based on structural model properties. Thus, the residual computation burden is avoided. The method can also handle faults of the extra placed sensors as well as the possibility of installing repeated sensors., This work has been funded by the Spanish Ministry of Science and Technology through the CICYT project WATMAN (ref. DPI2009-13744), and by the European Commission through contract i-Sense (ref. FP7-ICT-2009- 6-270428)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

FDI and FTC of wind turbines using the interval observer approach and virtual actuators/sensors

  • Blesa, Joaquim
  • Rotondo, Damiano
  • Puig, Vicenç
  • Nejjari, Fatiha
In this work, the problem of Fault Detection and Isolation (FDI) and Fault Tolerant Control (FTC) of wind turbines is addressed. Fault detection is based on the use of interval observers and unknown but bounded description of the noise and modeling errors. Fault isolation is based on analyzing the observed fault signatures on-line and matching them with the theoretical ones obtained using structural analysis and a row-reasoning scheme. Fault tolerant control is based on the use of virtual sensors/actuators to deal with sensor and actuator faults, respectively. More precisely, these FTC schemes, that have been proposed previously in state space form, are reformulated in input/output form. Since an active FTC strategy is used, the FTC module uses the information from the FDI module to replace the real faulty sensor/actuator by activating the corresponding virtual sensor/actuator. Virtual actuators/sensors require additionally a fault estimation module to compensate the fault. In this work, a fault estimation approach based on batch least squares is used. The performance of the proposed FDI and FTC schemes is assessed using the proposed fault scenarios considered in the wind turbine benchmark introduced in IFAC SAFEPROCESS 2009. Satisfactory results have been obtained in both FDI and FTC. © 2013 Elsevier Ltd., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428), by UPC through the grant FPIUPC E-01104 and by AGAUR through the contract FI-DGR 2013FIB00218., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Fault detection and isolation based on the combination of a bank of interval observers and invariant sets

  • Xu, Feng
  • Stoican, Florin
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
Presentado al 21st MED celebrado en Chania (Grecia) del 25 al 28 de junio de 2013., In this paper, a fault detection and isolation (FDI) approach using a bank of interval observers is developed. From the methodological point of view, a bank of interval observers is designed from different dynamical models of the system under healthy and faulty situations. Each dedicated interval observer matches one possible situation while all designed interval observers monitor the system simultaneously and independently. For the sake of guaranteed FDI, a set of FDI sufficient conditions are established based on invariant set notions. These conditions ensure that the faults can be accurately isolated after sufficiently long monitoring time. Finally, simulation results over a subsystem of a wind turbine are used to present the effectiveness of the proposed approach., The work of F. Xu, V. Puig and C. Ocampo-Martinez has been supported by the Spanish research project WATMAN (CICYT DPI2009-13744) of the Science and Technology Ministry and by the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), and by European Comission through contract i-Sense (FP7-ICT-2009-6-270428). F. Xu is also supported by the China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

On the relationship between interval observers and invariant sets in fault detection

  • Xu, Feng
  • Stoican, Florin
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
Presentado al SysTol 2013 celebrado en Niza del 9 al 11 de octubre., In this paper, the relationship between two set theoretic fault detection (FD) approaches, the interval observer based and the invariant set-based approaches, is investigated. In FD, interval observers monitor the system dynamic behavior in real time and generates adaptive intervals for system outputs. Invariant sets focus more on steady state behavior of the system rather than the transient behavior. This paper discusses these two approaches, presents the relationship between them and compares them in the FD task. At the end, a numerical example is used to illustrate the relation between these two approaches., The work of F. Xu, V. Puig and C. Ocampo-Martinez has been supported by Spanish research projects WAT-MAN (CICYT DPI2009-13744) and CICYT SHERECS DPI-2011-26243 of the Science and Technology Ministry, by the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), by European Comission through contract i-Sense (FP7-ICT-2009-6-270428), and by China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault detection and isolation using Interval observers

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
Presentado al SysTol 2013 celebrado en Niza del 9 al 11 de octubre., This paper proposes an interval observer-based sensor fault detection and isolation (FDI) approach for the closed-loop systems. In this proposed approach, residuals are defined in such a way that their components are independent of each other at the time instant after fault occurrence, namely kf + 1, where kf denotes the fault occurrence time instant. In this way, it is guaranteed that at kf + 1 the changes in each component of the residuals are only related to the fault in the corresponding sensor. By detecting the threshold violation of the corresponding residual interval components, the proposed method can detect and isolate sensor faults at that time instant. At the end of this paper, a numerical example is used to present the effectiveness of the approach., The work of F. Xu, V. Puig and C. Ocampo-Martinez has been supported by Spanish research project WATMAN (CICYT DPI2009-13744) of the Science and Technology Ministry, by the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), by European Comission through contract i-Sense (FP7-ICT-2009-6-270428), and by China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization under budgetary constraints

  • Sarrate, Ramon
  • Nejjari, Fatiha
  • Rosich, Albert
Presentado al 2nd International Conference on Systems and Control celebrado en Marruecos del 20 al 22 de junio de 2012., This paper presents a strategy based on fault diagnosability maximization to optimally locate sensors in complex systems. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of diagnosability and does not exceed a maximum sensor configuration cost. The strategy is based on the structural system model. Structural analysis is a powerful tool for dealing with complex nonlinear systems. The proposed approach is successfully applied to a Fuel Cell Stack System., This work has been funded by the Spanish Ministry of Science and Technology through the following projects CICYT WATMAN DPI2009-13744 and CICYT SHERECS DPI2011- 26243 and by European Comission through contract i-Sense FP7-ICT-2009- 6-270428., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Methodology for actuator fault tolerance evaluation of linear constrained MPC: Application to the Barcelona water network

  • Robles, Deneb
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Garza-Castañón, Luis E.
Presentado al 20th MED celebrado en Barcelona del 3 al 6 de julio de 2012., This paper presents a methodology to evaluate the admissibility of actuator fault configurations (AFC) when Linear Constrained Model Predictive Control (LCMPC) is used. The methodology combines the use of structural and feasability analysis. Structural analysis allows to evaluate the loss of reachability after a fault occurrence. The results of the structural analysis can be complemented with the feasibility analysis of the MPC problem taking into account the effect of actuator constraints after the fault occurrence. Additionally, a degradation analysis of the system performance can also be included. The proposed methodology is tested in the Barcelona water network., This work has been partially funded by the Spanish Ministry of Science and Technology through the following project SHERECS (Ref. DPI2011-26243), WATMAN (Ref. DPI2009-13744), and by European Comission through contract i-Sense (Ref. FP7-ICT-2009-6-270428)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization in distribution networks

  • Sarrate, Ramon
  • Nejjari, Fatiha
  • Rosich, Albert
20th Mediterranean Conference on Control & Automation: 518-523 (2012), The success of any diagnosis strategy critically depends on the sensors measuring process variables. This paper presents a strategy based on diagnosability maximization for optimally locating sensors in distribution networks. The goal is to characterize and determine the set of sensors that guarantees a maximum degree of diagnosability taking into account a given sensor configuration cardinality constraint. The strategy is based on the structural model of the system under consideration. Structural analysis is a powerful tool for determining diagnosis possibilities and evaluating whether the number and the location of sensors are adequate in order to meet some diagnosis specifications. The proposed approach is successfully applied to leakage detection in a Drinking Water Distribution Network., This work has been funded by the Spanish Ministry of Science and Technology through the CICYT project WATMAN (ref. DPI2009-13744), by the Spanish Ministry of Economy and Competitiveness through the CICYT projecte SHERECS (ref. DPI2011-26243), and by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Actuator-fault detection and isolation based on set-theoretic approaches

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
Energy Efficient Buildings Special Issue., In this paper, an actuator-fault detection and isolation (FDI) approach is proposed. The FDI approach is based on a bank of interval observers, each of which is designed to match a healthy or faulty system mode. To ensure reliable FDI for all considered actuator faults, a collection of invariant set-based FDI conditions are established for the proposed technique. Under these guaranteed FDI conditions, all the considered faults can be detected and isolated during the transition induced by fault occurrences. Comparing with the existing set-based FDI approaches, the advantage of the proposed technique consists in that it combines the advantages of interval observers in the transient-state functioning and the advantages of invariant sets in the steady-state functioning. This paper is completed with the study of a continuous stirred-tank reactor (CSTR), which illustrates the effectiveness of the proposed method., The work has been supported by the DGR of Generalitat de Catalunya (SAC group Ref.2009/SGR/1491), the grant SHERECS DPI2011- 26243, European Commission through contract i-Sense (FP7-ICT-2009-6-270428) and China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Closed-loop actuator-fault detection and isolation using set tubes and invariant sets

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
Trabajo presentado al 19th IFAC World Congress celebrado del 24 al 29 de agosto de 2014 en Cape Town (Sudafrica)., This paper proposes a new actuator-fault detection and isolation (FDI) strategy for closed-loop discrete time-invariant systems by using set tubes and invariant sets. In this approach, invariant sets are used for FDI and to establish FDI conditions, while set tubes are only generated for fault isolation (FI) during the transient state. Comparing to the existing relevant set-theoretic FDI techniques, the advantage of this approach consists in that it exhibits a balance between the conservativeness of FDI conditions and the rapidity of FI. The effectiveness of the proposed technique is illustrated by a numerical example., The work was supported by the DGR of Generalitat de Catalunya (AGAUR Doctorat Industrial 2013-DI-041), European Commission through contract i-Sense (FP7-ICT-2009-6-270428), and China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Fault diagnosis of a wind farm using interval parity equations

  • Blesa, Joaquim
  • Jiménez, Pedro
  • Rotondo, Damiano
  • Nejjari, Fatiha
  • Puig, Vicenç
Trabajo presentado al 19th IFAC World Congress celebrado del 24 al 29 de agosto de 2014 en Cape Town (Sudafrica)., In this paper, the problem of fault diagnosis of a wind farm is addressed using interval parity equations. Fault detection is based on the use of parity equations and unknown but bounded description of the noise and modeling errors. The fault detection test is based on checking the consistency between the measurements and the model by finding if the formers are inside the interval prediction bounds. The fault isolation algorithm is based on analyzing the observed fault signatures on-line, and matching them with the theoretical ones obtained using structural analysis. Finally, the proposed approach is tested using the wind farm benchmark proposed in the context of the wind farm FDI/FTC competition., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428) and by AGAUR through the contract FI-DGR 2013 (ref. 2013FIB00218)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Improved actuator-fault detection and isolation strategy using interval observers and invariant sets

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
Trabajo presentado al 19th IFAC World Congress celebrado del 24 al 29 de agosto de 2014 en Cape Town (Sudafrica)., In this paper, an improved algorithm for an actuator fault detection and isolation (FDI) framework using a bank of interval observers previously proposed by the authors is presented, where each interval observer matches one possible system mode. Under a set of FDI conditions, this new algorithm can accurately detect and isolate the considered actuator faults. The advantage of this new algorithm consists in that it extends the effectiveness of this FDI framework. At the end, a circuit example is used to illustrate the effectiveness of this approach., The work was supported by the DGR of Generalitat de Catalunya (AGAUR Doctorat Industrial 2013-DI-041), European Commission through contract i-Sense (FP7-ICT-2009-6-270428), and China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Model-based leak detection and location in water distribution networks considering an extended-horizon analysis of pressure sensitivities

  • Casillas, Myrna V.
  • Garza-Castañón, Luis E.
  • Puig, Vicenç
In this paper, we propose a new approach for model-based leak detection and location in water distribution networks (WDN), which considers an extended time-horizon analysis of pressure sensitivities. Five different ways of using the leak sensitivity matrix to isolate the leaks are described and compared. The first method is based on the binarization approach. The second, third and fourth methods are based on the comparison of the measured pressure vectors with the leak sensitivity matrix using different metrics: correlation, angle between vectors and Euclidean distance, respectively. The fifth method is based on the least square optimization method. The performance of these methods is compared when applied to two academic small networks (Hanoi and Quebra) widely used in the literature. Finally, the three methods with better performance are applied to a district metering area of the Barcelona WDN using real data., This work is supported by the Research Chair in Supervision and Advanced Control of Tecnológico de Monterrey, Campus Monterrey and by a CONACYT studentship. This work has been partially grant-funded by CICYT SHERECS DPI-2011-26243 and CICYT WATMAN DPI- 2009-13744 of the Spanish Ministry of Education and by iSense grant FP7-ICT-2009-6-270428 and by EFFINET grant FP7-ICT-2012-318556 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault tolerance using robust MPC with set-based state estimation and active fault isolation

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
  • Niculescu, Silviu-Iulian
Trabajo presentado a la 53rd IEEE Conference on Decision and Control (CDC 2014), celebrada del 15 al 17 de diciembre en Los Angeles, California (US)., In this paper, a sensor fault-tolerant control (FTC) scheme using robust model predictive control (MPC) and set theoretic fault detection and isolation (FDI) is proposed. The MPC controller is used to both robustly control the plant and actively guarantee fault isolation (FI). In this scheme, fault detection (FD) is passive by interval observers, while fault isolation (FI) is active by MPC. The advantage of the proposed approach consists in using MPC to actively decouple the effect of sensor faults on the outputs such that one output component only corresponds to one sensor fault in terms of FI, which can utilize the feature of sensor faults for FI. A numerical example is used to illustrate the effectiveness of the proposed scheme., This work has been partially supported by the EU project i-Sense (FP7-ICT-2009-6-270428), China Scholarship Council, CNRS-Supelec and Automatic Control Department, Supélec, France., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Robust MPC for actuator-fault tolerance using set-based passive fault detection and active fault isolation

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
  • Niculescu, Silviu-Iulian
Trabajo presentado a la 53rd IEEE Conference on Decision and Control (CDC 2014), celebrada del 15 al 17 de diciembre en Los Angeles, California (US)., In this paper, an actuator fault-tolerant control (FTC) scheme is proposed, which is based on tube-based model predictive control (MPC) and set-based fault detection and isolation (FDI). As a robust MPC technique, tube-based MPC can effectively deal with system constraints and uncertainties with relatively low complexity. Set-based FDI can implement robust fault diagnosis. In this scheme, fault detection (FD) is passive by invariant sets, while fault isolation (FI) is active by MPC and tubes. Using the constraint-handling ability of MPC, an active FI approach is implemented. This paper is ended up with an example to illustrate the effectiveness of the scheme., This work has been partially supported by the EU project i-Sense (FP7-ICT-2009-6-270428), China Scholarship Council, CNRS-Supelec and Automatic Control Department, Supélec, France., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Sensor placement for leak detection and location in water distribution networks

  • Sarrate, Ramon
  • Blesa, Joaquim
  • Nejjari, Fatiha
  • Quevedo, Joseba
Trabajo presentado al 7th IWA International Conference on Efficient Use and Management of Water (Efficient 2013), celebrado en Paris (Francia) del 22 al 25 de octubre de 2013., The performance of a leak detection and location algorithm depends on the set of measurements that are available in the network. This work presents an optimization strategy that maximizes the leak diagnosability performance of the network. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of diagnosability while the sensor configuration cost satisfies a budgetary constraint. To efficiently handle the complexity of the distribution network an efficient branch and bound search strategy based on a structural model is used. However, in order to reduce even more the size and the complexity of the problem the present work proposes to combine this methodology with clustering techniques. The strategy developed in this work is successfully applied to determine the optimal set of pressure sensors that should be installed in a District Metered Area in the Barcelona water distribution network., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), and by the European Commission through contracts i-Sense (ref. FP7-ICT-2009-6-270428) and EFFINET (ref. FP7-ICT2011-8-318556)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Robust quasi-LPV model reference FTC of a quadrotor UAV subject to actuator faults

  • Rotondo, Damiano
  • Nejjari, Fatiha
  • Puig, Vicenç
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License. (CC BY-NC-ND 3.0)., A solution for fault tolerant control (FTC) of a quadrotor unmanned aerial vehicle (UAV) is proposed. It relies on model reference-based control, where a reference model generates the desired trajectory. Depending on the type of reference model used for generating the reference trajectory, and on the assumptions about the availability and uncertainty of fault estimation, different error models are obtained. These error models are suitable for passive FTC, active FTC and hybrid FTC, the latter being able to merge the benefits of active and passive FTC while reducing their respective drawbacks. The controller is generated using results from the robust linear parameter varying (LPV) polytopic framework, where the vector of varying parameters is used to schedule between uncertain linear time invariant (LTI) systems. The design procedure relies on solving a set of linear matrix inequalities (LMIs) in order to achieve regional pole placement and H∞ norm bounding constraints. Simulation results are used to compare the different FTC strategies., This work has been funded by the Spanish MINECO through the project CICYT SHERECS (ref. DPI2011-26243), by the European Commission through the contract i-Sense (ref. FP7-ICT-2009-6-270428), by AGAUR through the contracts FI-DGR 2013 (ref. 2013FIB00218) and FI-DGR 2014 (ref. 2014FI_ B1 00172), and by the DGR of Generalitat de Catalunya (SAC group ref. 2014/SGR/374)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A fault-hiding approach for the switching quasi-LPV fault-tolerant control of a four-wheeled omnidirectional mobile robot

  • Rotondo, Damiano
  • Puig, Vicenç
  • Nejjari, Fatiha
  • Romera, Juli
This paper proposes a reference model approach for the trajectory tracking of a four-wheeled omnidirectional mobile robot. In particular, the error model is brought to a quasi-linear-parameter-varying (LPV) form suitable for designing an error-feedback controller. It is shown that, if polytopic techniques are used to reduce the number of constraints from infinite to finite, a solution within the standard LPV framework could not exist due to a singularity that appears in the possible values of the input matrix. Adding a switching component to the controller allows solving this problem. Moreover, a switching LPV virtual actuator is added to the control loop in order to obtain fault tolerance within the fault-hiding paradigm, keeping the stability and some desired performances under the effect of actuator faults without the need of retuning the nominal controller. The effectiveness of the proposed approach is shown and proved through simulation and experimental results., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428), by AGAUR through the contracts FI-DGR 2013 (ref. 2013FIB00218) and FI-DGR 2014 (ref. 2014FI B1 00172) and by the DGR of Generalitat de Catalunya (SAC group Ref. 2014/SGR/374)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

An interval NLPV parity equations approach for fault detection and isolation of a wind farm

  • Blesa, Joaquim
  • Jiménez, Pedro
  • Rotondo, Damiano
  • Nejjari, Fatiha
  • Puig, Vicenç
In this paper, the problem of fault diagnosis of a wind farm is addressed using interval nonlinear parameter-varying (NLPV) parity equations. Fault detection is based on the use of parity equations assuming unknown but bounded description of the noise and modeling errors. The fault detection test is based on checking the consistency between the measurements and the model, by finding if the formers are inside the interval prediction bounds. The fault isolation algorithm is based on analyzing the observed fault signatures online and matching them with the theoretical ones obtained using structural analysis. Finally, the proposed approach is tested using the wind farm benchmark proposed in the context of the wind farm faultdetection-and-isolation/fault-tolerant-control competition., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428), by AGAUR through the contracts FI-DGR 2013 (ref. 2013FIB00218) and FI-DGR 2014 (ref. 2014FI B1 00172) and by the DGR of Generalitat de Catalunya (SAC group Ref. 2014/SGR/374)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Automated generation and comparison of Takagi-Sugeno and polytopic quasi-LPV models

  • Rotondo, Damiano
  • Puig, Vicenç
  • Nejjari, Fatiha
  • Witczak, Marcin
In the last decades, gain-scheduling control techniques have consolidated as an efficient answer to analysis and synthesis problems for non-linear systems. Among the approaches proposed in the literature, the linear parameter varying (LPV) and Takagi-Sugeno (TS) paradigms have proved to be successful in dealing with the different trials that the analyzer, or the designer, of a gain-scheduled control system has to face. Despite the strong similarities between the two paradigms, research on LPV and TS systems has been performed in an independent way and some results that could be useful for both paradigms were obtained only for one of them. However, in recent works, some clues that there is a very close connection between LPV and TS worlds have been presented. The present paper openly addresses the presence of strong analogies between LPV and TS models, in an attempt to establish a bridge between these two worlds, so far considered different. In particular, this paper addresses the modeling problem, presenting two methods for the automated generation of LPV and TS systems, and introducing some measures in order to compare the obtained models. A mathematical example is used to illustrate the proposed methods., This work has been funded by the Spanish Ministry of Science and Technology through the projects CICYT SHERECS (Ref. DPI2011-26243) and CICYT ECOCIS (Ref. DPI2013-48243-C2-1-R), by the European Commission through contract i-Sense FP7-ICT-2009-6-270428, by UPC through the grant FPI-UPC E-01104, by AGAUR through the contracts FI-DGR 2013 (Ref. 2013FIB00218) and FI-DGR 2014 (Ref. 2014FI_B1 00172), and by the DGR of Generalitat de Catalunya (SAC group Ref. 2014/SGR/374). The work was also supported by the National Science Centre in Poland under the grant 2013/11/B/ST7/01110., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Tesis doctoral (DoctoralThesis)

Diagnosis and fault-tolerant control using set-based methods

  • Xu, Feng
[EN]: The fault-tolerant capability is an important performance specification for technical systems. Examples showing its importance are some catastrophes in civil aviation. According to official investigations, some air accidents due to failures are technically avoidable if the pilots can take right measures. But, relying on the skill and experience of the pilots, it cannot be guaranteed that reliable flight decisions are always made. Instead, if fault-tolerant strategies can be included in the decision-making procedure, it will be very useful for safer flight. Fault-tolerant control is generally classified into passive and active fault-tolerant control. Passive fault-tolerant control relies on the robustness of the controller, which can only provide limited fault-tolerant ability, while active fault-tolerant control turns to a fault detection and isolation module to obtain fault information and then to actively take actions to tolerate the effect of faults. Generally, active fault-tolerant control has more powerful fault-tolerant ability than passive fault-tolerant control. In this dissertation, one focuses on active fault-tolerant control, which for this case considers model predictive control and set-based fault detection and isolation. Model predictive control is a successful advanced control strategy in process industry and has been widely used for processes such as chemistry and water treatment, because of its ability to deal with multivariable constrained systems. However, the performance of model predictive control has deep dependence on model accuracy. Realistically, it is impossible to avoid the effect of modelling errors, disturbances, noises and faults, which always result in model mismatch. Comparatively, model mismatch induced by faults is possible to be effectively handled by suitable fault-tolerant strategies. The objective of this dissertation is to endow model predictive control with faulttolerant ability to improve its effectiveness. In order to reach this objective, set-based fault detection and isolation methods are used in the proposed fault-tolerant schemes. The important advantage of set-based fault detection and isolation is that it can make robust fault detection and isolation decisions, which is the key for taking right fault-tolerant measures. This dissertation includes four parts. The first part introduces this research, presents the state of the art and gives an introduction of used research tools. The second part proposes setbased fault detection and isolation for actuator and sensor faults, which is involved in interval observers and invariant sets. In the second part, the relationship between interval observers and invariant sets is firstly investigated. Then, actuator and sensor faults are separately coped with depending on their own features. The third part focuses on actuator and sensor fault-tolerant model predictive control, where the control strategy is robust model predictive control. The last part draws some conclusions, summarizes this research and gives clues for the future work., [ES]: La capacidad de los sistemas para tolerar fallos es una importante especificación de desempeño para la mayoría de sistemas. Ejemplos que muestran su importancia son algunas catástrofes en aviación civil. De acuerdo a investigaciones oficiales, algunos incidentes aéreos son técnicamente evitables si los pilotos pudiesen tomar las medidas adecuadas. Aun así, basándose en las habilidades y experiencia de los pilotos, no se puede garantizar que decisiones de vuelo confiables serán siempre posible de tomar. En cambio, si estrategias de tolerancia a fallos se pudieran incluir en el proceso de toma de decisión, los vuelos serían mucho más seguros. El control tolerante a fallos es generalmente clasificado en control pasivo y activo. El control pasivo se basa en la robustez del controlador, el cual sólo provee una habilidad limitada de tolerancia a fallos, mientras que el control tolerante a fallos de tipo activo se convierte en un modulo de detección y aislamiento de fallos que permite obtener información de éstos, y luego, activamente, tomar acciones para tolerar el efecto de dichos fallos. Así pues, el control activo generalmente tiene habilidades más fuertes de tolerancia a fallos. Esta tesis se enfoca en control tolerante a fallos activo, para lo cual considera el control predictivo basado en modelos y la detección y aislamiento de fallos basados en conjuntos. El control predictivo basado en modelos es una estrategia de control exitosa en la industria de procesos y ha sido ampliamente utilizada para procesos químicos y tratamiento de aguas, debido a su habilidad de tratar con sistemas multivariables con restricciones. A pesar de esto, el desempeño del control predictivo basado en modelos tiene una profunda dependencia de la precisión del modelo del sistema. Siendo realistas, es imposible evitar el efecto de errores de modelado, perturbaciones, ruidos y fallos, que siempre llevan a diferencias entre el modelo y el sistema real. Comparativamente, el error de modelo inducido por los fallos es posible de ser manejado efectivamente por estrategias adecuadas de control tolerante a fallos. Con el fin de alcanzar este objetivo, métodos de detección y aislamiento de fallos basados en conjuntos son utilizados en los esquemas de tolerancia a fallos propuestos en esta tesis. La ventaja importante de estas técnicas de detección y aislamiento de fallos basadas en conjuntos es que puede tomar decisiones robustas de detección y aislamiento, lo cual es clave para tomar medidas acertadas de tolerancia a fallos. Esta tesis esta dividida en cuatro partes. La primera parte es introductoria, presenta el estado del arte y hace una introducción a las herramientas de investigación utilizadas. La segunda parte expone la detección y aislamiento de fallos en actuadores y/o sensores, basándose en teoría de conjuntos, a partir de observadores de intervalo, y conjuntos invariantes. La tercera parte se enfoca en el control predictivo robusto (con enfoques basados tanto en tubos robustos como en min-max) con tolerancia a fallos en actuadores y/o sensores. La cuarta parte presenta algunas conclusiones, hace un resume de esta investigación y da algunas ideas para trabajos futuros., I want to thank the projects/grants that partially finance my research. They are the Spanish research projects CICYT SHERECS DPI-2011-26243 and WATMAN (DPI2009-13744) of the Science and Technology Ministry, the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491) and the contract i-Sense (FP7-ICT-2009-6-270428) by the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Set-membership parity space approach for fault detection in linear uncertain dynamic systems

  • Blesa, Joaquim
  • Puig, Vicenç
  • Saludes, Jordi
  • Fernández Cantí, Rosa M.
Special Issue: Set-Membership Methods Applied to FDI and FTC., In this paper, a set-membership parity space approach for linear uncertain dynamic systems is proposed. First, a set of parity relations derived from the parity space approach is obtained by means of a transformation derived from the system characteristic polynomial. As a result of this transformation, parity relations can be expressed in regressor form. On the one hand, this facilitates the parameter estimation of those relations using a zonotopic set-membership algorithm. On the other hand, fault detection is then based on checking, at every sample time, the non-existence of a parameter value in the parameter uncertainty set such that the model is consistent with all the system measurements. The proposed approach is applied to two examples: a first illustrative case study based on a two-tank system and a more realistic case study based on the wind turbine fault detection and isolation benchmark in order to evaluate its effectiveness., This work has been partially funded by the grant CICYT SHERECS DPI-2011-26243 of Spanish Ministry of Education and by the European contract i-Sense (ref FP7-ICT-2009-6-270428), Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Set-membership identification and fault detection using a Bayesian framework

  • Fernández Cantí, Rosa M.
  • Blesa, Joaquim
  • Puig, Vicenç
  • Tornil-Sin, Sebastian
This paper deals with the problem of set-membership identification and fault detection using a Bayesian framework. The paper presents how the set-membership model estimation problem can be reformulated from the Bayesian viewpoint in order to, first, determine the feasible parameter set in the identification stage and, second, check the consistency between the measurement data and the model in the fault-detection stage. The paper shows that, assuming uniform distributed measurement noise and uniform model prior probability distributions, the Bayesian approach leads to the same feasible parameter set than the well-known set-membership technique based on approximating the feasible parameter set using sets. Additionally, it can deal with models that are nonlinear in the parameters. The single-output and multiple-output cases are addressed as well. The procedure and results are illustrated by means of the application to a quadruple-tank process., This work has been partially grant-funded by CICYT SHERECS DPI-2011-26243 and CICYT WATMAN DPI-2009-13744 of the Spanish Ministry of Education and by i-Sense grant FP7-ICT-2009-6-270428 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Set-theoretic methods in robust detection and isolation of sensor faults

  • Xu, Feng
  • Puig, Vicenç
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
  • Stoican, Florin
This paper proposes a sensorfault detection and isolation (FDI) approach based on interval observers and invariant sets. In fault detection (FD), both interval observer-based and invariant set-based mechanisms are used to provide real-time fault alarms. In fault isolation (FI), the proposed approach also uses these two different mechanisms. The former, based on interval observers, aims to isolate faults during the transient-state operation induced by faults. If the former does not succeed, the latter, based on both interval observers and invariant sets, is started to guarantee FI after the system enters into steady state. Besides, a collection of invariant set-based FDI conditions are established by using all available system-operating information provided by all interval observers. In order to reduce computational complexity, a method to remove all available but redundant/unnecessary system-operating information is incorporated into this approach. If the considered faults satisfy the proposed FDI conditions, it can be guaranteed that they are detectable and isolable after their occurrences. This paper concludes with a case study based on a subsystem of a wind turbine benchmark, which can illustrate the effectiveness of this FDI technique., The work has been partially funded by the DGR of Generalitat de Catalunya (SAC group Ref.2009/SGR/1491), European Commission through contract i-Sense (FP7-ICT-2009-6-270428), China Scholarship Council (File No.2011629170), and the Sectoral Operational Programme Human Resources Development 2007-2013 of the Ministry of European Funds through the Financial Agreement POSDRU/159/1.5/S/132395., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Non-linear set-membership identification approach based on the Bayesian framework

  • Fernández Cantí, Rosa M.
  • Tornil-Sin, Sebastian
  • Blesa, Joaquim
  • Puig, Vicenç
This study deals with the problem of set-membership identification of non-linear-in-the-parameters models. To solve this problem, this study illustrates how the Bayesian approach can be used to determine the feasible parameter set (FPS) by assuming uniform distributed estimation error and flat model prior probability distributions. The key point of the methodology is the interval evaluation of the likelihood function and the result is a set of boxes with associated credibility indices. For each box, the credibility index is in the interval (0, 1] and gives information about the amount of consistent models inside the box. The union of the boxes with credibility value equal to one provides an inner approximation of the FPS, whereas the union of all boxes provides an outer estimation. The boxes with credibility value smaller than one are located around the boundary of the FPS and their credibility index can be used to iteratively refine the inner and outer approximations up to a desired precision. The main issues and performance of the developed algorithms are discussed and illustrated by means of examples., This work has been partially grant-funded by CICYT SHERECS DPI-2011-26243 and CICYT ECOCIS (Ref.DPI2013-48243-C2-1-R) DPI-2009-13744 of the Spanish Ministry of Education and by i-Sense grant FP7-ICT-2009-6-270428 of the European Commission., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Tesis doctoral (DoctoralThesis)

On model predictive control for economic and robust operation of generalised flow-based networks

  • Grosso, J. M.
Universitat Politècnica de Catalunya. Programa de Doctorat: Automàtica, Robòtica I Visió., [EN]: This thesis is devoted to design Model Predictive Control (MPC) strategies aiming to enhance the management of constrained generalised flow-based networks, with special attention to the economic optimisation and robust performance of such systems. Several control schemes are developed in this thesis to exploit the available economic information of the system operation and the disturbance information obtained from measurements and forecasting models. Dynamic network flows theory is used to develop control-oriented models that serve to design MPC controllers specialised for flow networks with additive disturbances and periodically time-varying dynamics and costs. The control strategies developed in this thesis can be classified in two categories: centralised MPC strategies and non-centralised MPC strategies. Such strategies are assessed through simulations of a real case study: the Barcelona drinking water network (DWN). Regarding the centralised strategies, different economic MPC formulations are first studied to guarantee recursive feasibility and stability under nominal periodic flow demands and possibly time-varying economic parameters and multi-objective cost functions. Additionally, reliability-based MPC, chance-constrained MPC and tree-based MPC strategies are proposed to address the reliability of both the flow storage and the flow transportation tasks in the network. Such strategies allow to satisfy a customer service level under future flow demand uncertainty and to efficiently distribute overall control effort under the presence of actuators degradation. Moreover, soft-control techniques such as artificial neural networks and fuzzy logic are used to incorporate self-tuning capabilities to an economic certainty-equivalent MPC controller. Since there are objections to the use of centralised controllers in large-scale networks, two non-centralised strategies are also proposed. First, a multi-layer distributed economic MPC strategy of low computational complexity is designed with a control topology structured in two layers. In a lower layer, a set of local MPC agents are in charge of controlling partitions of the overall network by exchanging limited information on shared resources and solving their local problems in a hierarchical-like fashion. Moreover, to counteract the loss of global economic information due to the decomposition of the overall control task, a coordination layer is designed to influence non-iteratively the decision of local controllers towards the improvement of the overall economic performance. Finally, a cooperative distributed economic MPC formulation based on a periodic terminal cost/region is proposed. Such strategy guarantees convergence to a Nash equilibrium without the need of a coordinator and relies on an iterative and global communication of local controllers, which optimise in parallel their control actions but using a centralised model of the network., [ES]: Esta tesis se enfoca en el diseño de estrategias de control predictivo basado en modelos (MPC, por sus siglas en inglés) con la meta de mejorar la gestión de sistemas que pueden ser descritos por redes generalizadas de flujo y que están sujetos a restricciones, enfatizando especialmente en la optimización económica y el desempeño robusto de tales sistemas. De esta manera, varios esquemas de control se desarrollan en esta tesis para explotar tanto la información económica disponible de la operación del sistema como la información de perturbaciones obtenida de datos medibles y de modelos de predicción. La teoría de redes dinámicas de flujo es utilizada en esta tesis para desarrollar modelos orientados a control que sirven para diseñar controladores MPC especializados para la gestión de redes de flujo que presentan tanto perturbaciones aditivas como dinámicas y costos periódicamente variables en el tiempo. Las estrategias de control propuestas en esta tesis se pueden clasificar en dos categorías: estrategias de control MPC centralizado y estrategias de control MPC no-centralizado. Dichas estrategias son evaluadas mediante simulaciones de un caso de estudio real: la red de transporte de agua potable de Barcelona en España. En cuanto a las estrategias de control MPC centralizado, diferentes formulaciones de controladores MPC económicos son primero estudiadas para garantizar factibilidad recursiva y estabilidad del sistema cuya operación responde a demandas nominales de flujo periódico, a parámetros económicos posiblemente variantes en el tiempo y a funciones de costo multi-objetivo. Adicionalmente, estrategias de control MPC basado en fiabilidad, MPC con restricciones probabilísticas y MPC basado en árboles de escenarios son propuestas para garantizar la fiabilidad tanto de tareas de almacenamiento como de transporte de flujo en la red. Tales estrategias permiten satisfacer un nivel de servicio al cliente bajo incertidumbre en la demanda futura, así como distribuir eficientemente el esfuerzo global de control bajo la presencia de degradación en los actuadores del sistema. Por otra parte, técnicas de computación suave como redes neuronales artificiales y lógica difusa se utilizan para incorporar capacidades de auto-sintonía en un controlador MPC económico de certeza-equivalente. Dado que hay objeciones al uso de control centralizado en redes de gran escala, dos estrategias de control no-centralizado son propuestas en esta tesis. Primero, un controlador MPC económico distribuido de baja complejidad computacional es diseñado con una topología estructurada en dos capas. En una capa inferior, un conjunto de controladores MPC locales se encargan de controlar particiones de la red mediante el intercambio de información limitada de los recursos físicos compartidos y resolviendo sus problemas locales de optimización de forma similar a una secuencia jerárquica de solución. Para contrarrestar la pérdida de información económica global que ocurra tras la descomposición de la tarea de control global, una capa de coordinación es diseñada para influenciar no-iterativamente la decisión de los controles locales con el fin de lograr una mejora global del desempeño económico. La segunda estrategia no-centralizada propuesta en esta tesis es una formulación de control MPC económico distribuido cooperativo basado en una restricción terminal periódica. Tal estrategia garantiza convergencia a un equilibrio de Nash sin la necesidad de una capa de coordinación pero requiere una comunicación iterativa de información global entre todos los controladores locales, los cuales optimizan en paralelo sus acciones de control utilizando un modelo centralizado de la red., The work presented in this thesis has been partially supported by the EU projects EFFINET (FP7-ICT-2011-8-31855) and i-Sense (FP7-ICT-2009-6-270428), and by the Spanish projects ECOCIS (CICYT DPI2013-48243-C2-1-R) and SHERECS (CICYT DPI2011-26243) of the Ministry of Economy and Competitiveness, WATMAN (CICYT DPI2009-13744) of the Ministry of Science and Technology and the DGR of Generalitat de Catalunya (SAC group Ref. 2014/SGR/374)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Automated generation and comparison of Takagi–Sugeno and polytopic quasi-LPV models

  • Rotondo, Damiano|||0000-0002-8855-5582
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Witczak, Marcin
In the last decades, gain-scheduling control techniques have consolidated as an efficient answer to analysis and synthesis problems for non-linear systems. Among the approaches proposed in the literature, the linear parameter varying (LPV) and Takagi–Sugeno (TS) paradigms have proved to be successful in dealing with the different trials that the analyzer, or the designer, of a gain-scheduled control system has to face. Despite the strong similarities between the two paradigms, research on LPV and TS systems has been performed in an independent way and some results that could be useful for both paradigms were obtained only for one of them. However, in recent works, some clues that there is a very close connection between LPV and TS worlds have been presented. The present paper openly addresses the presence of strong analogies between LPV and TS models, in an attempt to establish a bridge between these two worlds, so far considered different. In particular, this paper addresses the modeling problem, presenting two methods for the automated generation of LPV and TS systems, and introducing some measures in order to compare the obtained models. A mathematical example is used to illustrate the proposed methods., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Robust Fault Detection using Polytope-based Set-membership Consistency Test

  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Saludes Closa, Jordi|||0000-0002-6666-1982
This article proposes a robust set-membership fault detection method based on the use of polytopes to bound the parameter uncertainty set. The proposed polytope-based fault detection algorithm is able to handle systems with bounded parameter variation between samples. It is shown that consistency checks indicating faults can be performed in a natural manner with a polytope description of the feasible parameter set.. Finally, an application example is given, which demonstrates how the algorithm works on a simulated process(a four-tank system). A comparison with a zonotope-based faultdetection approach recently proposed in the literature is included.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Garza Castañón, Luís Eduardo
  • Rosich, Albert
This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Robust MPC for actuator-fault tolerance using set-based passive fault detection and active fault isolation

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Olaru, Sorin
  • Niculescu, Silviu-Iulian
In this paper, an actuator fault-tolerant control (FTC) scheme is proposed, which is based on tube-based model predictive control (MPC) and set-theoretic fault detection and isolation (FDI). As a robust MPC technique, tube-based MPC, can effectively deal with system constraints and uncertainties with relatively low computational complexity. Set-based FDI can robustly detect and isolate actuator faults. Here, fault detection (FD) is passive by invariant sets, while fault isolation (FI) is active by tubes. Using the constraint-handling ability of MPC controllers, an active FI approach is implemented. A numerical example illustrates the effectiveness of the proposed approach.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Application of predictive control strategies to the management of complex networks in the urban water cycle

  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Cembrano Gennari, Gabriela|||0000-0003-1436-6022
  • Quevedo Casín, Joseba Jokin|||0000-0002-7827-2896
The management of the urban water cycle (UWC) is a subject of increasing interest because of its social, economic, and environmental impact. The most important issues include the sustainable use of limited resources and the reliability of service to consumers with adequate quality and pressure levels, as well as the urban drainage management to prevent flooding and polluting discharges to the environment., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Model-based optimal sensor placement approaches to fuel cell stack system fault diagnosis

  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Rosich Oliva, Albert
The problem of optimal sensor placement for FDI consists in d etermining the set of sensors that minimizes a pre-defined cost function satisfying at the same time a pre-established set of FDI specifications for a given set of faults. This paper recalls t hree model-based optimal sensor location approaches: an Incremental search, a Heuristic search and a Binary Integer Linear Programming (BILP) formulation. The main contribution of this paper is a compar ative study that addresses efficiency, flexibility and other issues. The performance of the approac hes is demonstrated by an application to a fuel cell stack system., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Tesis doctoral (DoctoralThesis)

On model predictive control for economic and robust operation of generalised flow-based networks

  • Grosso Pérez, Juan Manuel|||0000-0002-4300-1500
This thesis is devoted to design Model Predictive Control (MPC) strategies aiming to enhance the management of constrained generalised flow-based networks, with special attention to the economic optimisation and robust performance of such systems. Several control schemes are developed in this thesis to exploit the available economic information of the system operation and the disturbance information obtained from measurements and forecasting models. Dynamic network flows theory is used to develop control-oriented models that serve to design MPC controllers specialised for flow networks with additive disturbances and periodically time-varying dynamics and costs. The control strategies developed in this thesis can be classified in two categories: centralised MPC strategies and non-centralised MPC strategies. Such strategies are assessed through simulations of a real case study: the Barcelona drinking water network (DWN). Regarding the centralised strategies, different economic MPC formulations are first studied to guarantee recursive feasibility and stability under nominal periodic flow demands and possibly time-varying economic parameters and multi-objective cost functions. Additionally, reliability-based MPC, chance-constrained MPC and tree-based MPC strategies are proposed to address the reliability of both the flow storage and the flow transportation tasks in the network. Such strategies allow to satisfy a customer service level under future flow demand uncertainty and to efficiently distribute overall control effort under the presence of actuators degradation. Moreover, soft-control techniques such as artificial neural networks and fuzzy logic are used to incorporate self-tuning capabilities to an economic certainty-equivalent MPC controller. Since there are objections to the use of centralised controllers in large-scale networks, two non-centralised strategies are also proposed. First, a multi-layer distributed economic MPC strategy of low computational complexity is designed with a control topology structured in two layers. In a lower layer, a set of local MPC agents are in charge of controlling partitions of the overall network by exchanging limited information on shared resources and solving their local problems in a hierarchical-like fashion. Moreover, to counteract the loss of global economic information due to the decomposition of the overall control task, a coordination layer is designed to influence non-iteratively the decision of local controllers towards the improvement of the overall economic performance. Finally, a cooperative distributed economic MPC formulation based on a periodic terminal cost/region is proposed. Such strategy guarantees convergence to a Nash equilibrium without the need of a coordinator and relies on an iterative and global communication of local controllers, which optimise in parallel their control actions but using a centralised model of the network., Esta tesis se enfoca en el diseño de estrategias de control predictivo basado en modelos (MPC, por sus siglas en inglés) con la meta de mejorar la gestión de sistemas que pueden ser descritos por redes generalizadas de flujo y que están sujetos a restricciones, enfatizando especialmente en la optimización económica y el desempeño robusto de tales sistemas. De esta manera, varios esquemas de control se desarrollan en esta tesis para explotar tanto la información económica disponible de la operación del sistema como la información de perturbaciones obtenida de datos medibles y de modelos de predicción. La teoría de redes dinámicas de flujo es utilizada en esta tesis para desarrollar modelos orientados a control que sirven para diseñar controladores MPC especializados para la gestión de redes de flujo que presentan tanto perturbaciones aditivas como dinámicas y costos periódicamente variables en el tiempo. Las estrategias de control propuestas en esta tesis se pueden clasificar en dos categorías: estrategias de control MPC centralizado y estrategias de control MPC no-centralizado. Dichas estrategias son evaluadas mediante simulaciones de un caso de estudio real: la red de transporte de agua potable de Barcelona en España. En cuanto a las estrategias de control MPC centralizado, diferentes formulaciones de controladores MPC económicos son primero estudiadas para garantizar factibilidad recursiva y estabilidad del sistema cuya operación responde a demandas nominales de flujo periódico, a parámetros económicos posiblemente variantes en el tiempo y a funciones de costo multi-objetivo. Adicionalmente, estrategias de control MPC basado en fiabilidad, MPC con restricciones probabilísticas y MPC basado en árboles de escenarios son propuestas para garantizar la fiabilidad tanto de tareas de almacenamiento como de transporte de flujo en la red. Tales estrategias permiten satisfacer un nivel de servicio al cliente bajo incertidumbre en la demanda futura, así como distribuir eficientemente el esfuerzo global de control bajo la presencia de degradación en los actuadores del sistema. Por otra parte, técnicas de computación suave como redes neuronales artificiales y lógica difusa se utilizan para incorporar capacidades de auto-sintonía en un controlador MPC económico de certeza-equivalente. Dado que hay objeciones al uso de control centralizado en redes de gran escala, dos estrategias de control no-centralizado son propuestas en esta tesis. Primero, un controlador MPC económico distribuido de baja complejidad computacional es diseñado con una topología estructurada en dos capas. En una capa inferior, un conjunto de controladores MPC locales se encargan de controlar particiones de la red mediante el intercambio de información limitada de los recursos físicos compartidos y resolviendo sus problemas locales de optimización de forma similar a una secuencia jerárquica de solución. Para contrarrestar la pérdida de información económica global que ocurra tras la descomposición de la tarea de control global, una capa de coordinación es diseñada para influenciar no-iterativamente la decisión de los controles locales con el fin de lograr una mejora global del desempeño económico. La segunda estrategia no-centralizada propuesta en esta tesis es una formulación de control MPC económico distribuido cooperativo basado en una restricción terminal periódica. Tal estrategia garantiza convergencia a un equilibrio de Nash sin la necesidad de una capa de coordinación pero requiere una comunicación iterativa de información global entre todos los controladores locales, los cuales optimizan en paralelo sus acciones de control utilizando un modelo centralizado de la red.
UPCommons. Portal del coneixement obert de la UPC
Publicación Tesis doctoral (DoctoralThesis)

Diagnosis and fault-tolerant control using set-based methods

  • Xu, Feng
The fault-tolerant capability is an important performance specification for most of technical systems. The examples showing its importance are some catastrophes in civil aviation. According to some official investigations, some air incidents are technically avoidable if the pilots can take right measures. But, relying on the skill and experience of the pilots, it cannot be guaranteed that reliable flight decisions are always made. Instead, if fault-tolerant strategies can be included in the decision-making procedure, it will be very useful for safer flight. Fault-tolerant control is generally classified into passive and active fault-tolerant control. Passive fault-tolerant control relies on robustness of controller, which can only provide limited fault-tolerant ability, while active fault-tolerant control turns to a fault detection and isolation module to obtain fault information and then actively take actions to tolerate the effect of faults. Thus, active fault-tolerant control generally has stronger fault-tolerant ability. In this dissertation, one focuses on active fault-tolerant control, which for this case considers model predictive control and set-based fault detection and isolation. Model predictive control is a successful advanced control strategy in process industry and has been widely used for processes such as chemistry and water treatment, because of its ability to deal with multivariable constrained systems. However, the performance of model redictive control has deep dependence on system-model accuracy. Realistically, it is impossible to avoid the effect of modelling errors, disturbances, noises and faults, which always result in model mismatch. Comparatively, model mismatch induced by faults is possible to be effectively handled by suitable fault-tolerant strategies. The objective of this dissertation is to endow model predictive control with fault-tolerant ability to improve its effectiveness. In order to reach this objective, set-based fault detection and isolation methods are used in the proposed fault-tolerant schemes. The important advantage of set-based fault detection and isolation is that it can make robust fault detection and isolation decisions, which is key for taking right fault-tolerant measures. This dissertation includes four parts. The first part introduces this research, presents the state of the art and gives an introduction of used research tools. The second part proposes set-based fault detection and isolation for actuator or=and sensor faults, which are involved in interval observers, invariant sets and set-membership estimation. First, the relationship between interval observers and invariant sets is investigated. Then, actuator and sensor faults are separately coped with depending on their own features. The third part focuses on actuator or=and sensor fault-tolerant model predictive control, where the control strategy is robust model predictive control (tube-based and min-max approaches). The last part draws some conclusions, summarizes this research and gives clues for the further work., La capacidad de los sistemas para tolerar fallos es una importante especificación de desempeño para la mayoría de sistemas. Ejemplos que muestran su importancia son algunas catástrofes en aviación civil. De acuerdo a investigaciones oficiales, algunos incidentes aéreos son técnicamente evitables si los pilotos pudiesen tomar las medidas adecuadas. Aun así, basándose en las habilidades y experiencia de los pilotos, no se puede garantizar que decisiones de vuelo confiables serán siempre posible de tomar. En cambio, si estrategias de tolerancia a fallos se pudieran incluir en el proceso de toma de decisión, los vuelos serían mucho más seguros. El control tolerante a fallos es generalmente clasificado en control pasivo y activo. El control pasivo se basa en la robustez del controlador, el cual sólo provee una habilidad limitada de tolerancia a fallos, mientras que el control tolerante a fallos de tipo activo se convierte en un modulo de detección y aislamiento de fallos que permite obtener información de éstos, y luego, activamente, tomar acciones para tolerar el efecto de dichos fallos. Así pues, el control activo generalmente tiene habilidades más fuertes de tolerancia a fallos. Esta tesis se enfoca en control tolerante a fallos activo, para lo cual considera el control predictivo basado en modelos y la detección y aislamiento de fallos basados en conjuntos. El control predictivo basado en modelos es una estrategia de control exitosa en la industria de procesos y ha sido ampliamente utilizada para procesos químicos y tratamiento de aguas, debido a su habilidad de tratar con sistemas multivariables con restricciones. A pesar de esto, el desempeño del control predictivo basado en modelos tiene una profunda dependencia de la precisión del modelo del sistema. Siendo realistas, es imposible evitar el efecto de errores de modelado, perturbaciones, ruidos y fallos, que siempre llevan a diferencias entre el modelo y el sistema real. Comparativamente, el error de modelo inducido por los fallos es posible de ser manejado efectivamente por estrategias adecuadas de control tolerante a fallos. Con el fin de alcanzar este objetivo, métodos de detección y aislamiento de fallos basados en conjuntos son utilizados en los esquemas de tolerancia a fallos propuestos en esta tesis. La ventaja importante de estas técnicas de detección y aislamiento de fallos basadas en conjuntos es que puede tomar decisiones robustas de detección y aislamiento, lo cual es clave para tomar medidas acertadas de tolerancia a fallos. Esta tesis esta dividida en cuatro partes. La primera parte es introductoria, presenta el estado del arte y hace una introducción a las herramientas de investigación utilizadas. La segunda parte expone la detección y aislamiento de fallos en actuadores y/o sensores, basándose en teoría de conjuntos, a partir de observadores de intervalo, y conjuntos invariantes. La tercera parte se enfoca en el control predictivo robusto (con enfoques basados tanto en tubos robustos como en min-max) con tolerancia a fallos en actuadores y/o sensores. La cuarta parte presenta algunas conclusiones, hace un resumen de esta investigación y da algunas ideas para trabajos futuros.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Actuator-fault detection and isolation based on set-theoretic approaches

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an actuator-fault detection and isolation (FDI) approach is proposed. The FDI approach is based on a bank of interval observers, each of which is designed to match a healthy or faulty system mode. To ensure reliable FDI for all considered actuator faults, a collection of invariant set-based FDI conditions are established for the proposed technique. Under these guaranteed FDI conditions, all the considered faults can be detected and isolated during the transition induced by fault occurrences. Comparing with the existing set-based FDI approaches, the advantage of the proposed technique consists in that it combines the advantages of interval observers in the transient-state functioning and the advantages of invariant sets in the steady-state functioning. This paper is completed with the study of a continuous stirred-tank reactor (CSTR), which illustrates the effectiveness of the proposed method. (C) 2014 Elsevier Ltd. All rights reserved.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Non-linear set-membership identification approach based on the Bayesian framework

  • Fernández Canti, Rosa M.|||0000-0002-9381-6601
  • Tornil Sin, Sebastián|||0000-0003-1799-2192
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
This study deals with the problem of set-membership identification of non-linear-in-the-parameters models. To solve this problem, this study illustrates how the Bayesian approach can be used to determine the feasible parameter set (FPS) by assuming uniform distributed estimation error and flat model prior probability distributions. The key point of the methodology is the interval evaluation of the likelihood function and the result is a set of boxes with associated credibility indices. For each box, the credibility index is in the interval (0, 1] and gives information about the amount of consistent models inside the box. The union of the boxes with credibility value equal to one provides an inner approximation of the FPS, whereas the union of all boxes provides an outer estimation. The boxes with credibility value smaller than one are located around the boundary of the FPS and their credibility index can be used to iteratively refine the inner and outer approximations up to a desired precision. The main issues and performance of the developed algorithms are discussed and illustrated by means of examples., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Set-theoretic methods in robust detection and isolation of sensor faults

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Olaru, Sorin
  • Stoican, Florin
This paper proposes a sensor-fault detection and isolation (FDI) approach based on interval observers and invariant sets. In fault detection (FD), both interval observer-based and invariant set-based mechanisms are used to provide real-time fault alarms. In fault isolation (FI), the proposed approach also uses these two different mechanisms. The former, based on interval observers, aims to isolate faults during the transient-state operation induced by faults. If the former does not succeed, the latter, based on both interval observers and invariant sets, is started to guarantee FI after the system enters into steady state. Besides, a collection of invariant set-based FDI conditions are established by using all available system-operating information provided by all interval observers. In order to reduce computational complexity, a method to remove all available but redundant/unnecessary system-operating information is incorporated into this approach. If the considered faults satisfy the proposed FDI conditions, it can be guaranteed that they are detectable and isolable after their occurrences. This paper concludes with a case study based on a subsystem of a wind turbine benchmark, which can illustrate the effectiveness of this FDI technique.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Closed-loop actuator-fault detection and isolation using invariant set and tubes

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes a new actuator-fault detection and isolation (FDI) strategy for closed-loop discrete time-invariant systems by using invariant sets and tubes. In this approach, invariant sets are used for fault detection (FD) and the establishment of FDI conditions, while the tubes are generated for fault isolation (FI) at transient state. Comparing with the existing set-theoretic FDI techniques, the advantage of this approach consists in that it exhibits a balance between the conservativeness of FDI conditions, the fast FI response and the computational complexity. The eectiveness of the proposed technique is illustrated by a numerical example.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Set-membership parity space approach for fault detection in linear uncertain dynamic systems

  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Saludes Closa, Jordi|||0000-0002-6666-1982
  • Fernández Canti, Rosa M.|||0000-0002-9381-6601
In this paper, a set-membership parity space approach for linear uncertain dynamic systems is proposed. First, a set of parity relations derived from the parity space approach is obtained by means of a transformation derived from the system characteristic polynomial. As a result of this transformation, parity relations can be expressed in regressor form. On the one hand, this facilitates the parameter estimation of those relations using a zonotopic set-membership algorithm. On the other hand, fault detection is then based on checking, at every sample time, the non-existence of a parameter value in the parameter uncertainty set such that the model is consistent with all the system measurements. The proposed approach is applied to two examples: a first illustrative case study based on a two-tank system and a more realistic case study based on the wind turbine fault detection and isolation benchmark in order to evaluate its effectiveness, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Searching force-closure optimal grasps of articulated 2D objects with n links

  • Alvarado Tovar, Noé
  • Suárez Feijóo, Raúl|||0000-0002-3853-7095
This paper proposes a method that finds a locally optimal grasp of an articulated 2D object with n links considering frictionless contacts. The surface of each link of the object is represented by a finite set of points, thus it may have any shape. The proposed approach finds, first, an initial force-closure grasp and from it starts an iterative search of a local optimum grasp. The quality measure considered in this work is the largest perturbation wrench that a grasp can resist with independence of the direction of the perturbation. The approach has been implemented and some illustrative examples are included in the article.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault tolerance using robust MPC with set-based state estimation and active fault isolation

  • Xu, Feng
  • Olaru, Sorin
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Niculescu, Silviu-Iulian
In this paper, a sensor fault-tolerant control (FTC) scheme using robust model predictive control (MPC) and set theoretic fault detection and isolation (FDI) is proposed. The MPC controller is used to both robustly control the plant and actively guarantee fault isolation (FI). In this scheme, fault detection (FD) is passive by interval observers, while fault isolation (FI) is active by MPC. The advantage of the proposed approach consists in using MPC to actively decouple the effect of sensor faults on the outputs such that one output component only corresponds to one sensor fault in terms of FI, which can utilize the feature of sensor faults for FI. A numerical example is used to illustrate the effectiveness of the proposed scheme.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Fault detection and isolation based on the combination of a bank of interval observers and invariant sets

  • Xu, Feng
  • Stoican, Florin
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Olaru, Sorin
In this paper, a fault detection and isolation (FDI) approach using a bank of interval observers is developed. From the methodological point of view, a bank of interval observers is designed according to different dynamical models of the system under different modes (healthy or faulty). Each interval observer matches one system mode while all the interval observers monitor the system simultaneously. In order to guarantee FDI, a set of FDI conditions based on invariant set notions are established. These conditions ensure that the considered faults can be accurately isolated after a period of monitoring time. Finally, simulation results are used to present the effectiveness of the approach.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Robust identification and fault diagnosis based on uncertain multiple input-multiple output linear parameter varying parity equations and zonotopes

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Set-membership identification and fault detection using a Bayesian framework

  • Fernández Canti, Rosa M.|||0000-0002-9381-6601
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Tornil Sin, Sebastián|||0000-0003-1799-2192
This paper deals with the problem of set-membership identification and fault detection using a Bayesian framework. The paper presents how the set-membership model estimation problem can be reformulated from the Bayesian viewpoint in order to, first, determine the feasible parameter set in the identification stage and, second, check the consistency between the measurement data and the model in the fault-detection stage. The paper shows that, assuming uniform distributed measurement noise and uniform model prior probability distributions, the Bayesian approach leads to the same feasible parameter set than the well-known set-membership technique based on approximating the feasible parameter set using sets. Additionally, it can deal with models that are nonlinear in the parameters. The single-output and multiple-output cases are addressed as well. The procedure and results are illustrated by means of the application to a quadruple-tank process., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Fault Diagnosis of a Wind Farm using Interval Parity Equations

  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Jiménez, P.
  • Rotondo, Damiano|||0000-0002-8855-5582
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
Segon Premi a la "Competition on Wind Farm Fault Accomodation", atorgat per l'Aalborg University, al 19th. World Congress of the International Federation of Automatic Control, In this paper, the problem of fault diagnosis of a wind farm is addressed using interval parity equations. Fault detection is based on the use of parity equations and unknown but bounded description of the noise and modeling errors. The fault detection test is based on checking the consistency between the measurements and the model by finding if the formers are inside the interval prediction bounds. The fault isolation algorithm is based on analyzing the observed fault signatures on-line, and matching them with the theoretical ones obtained using structural analysis. Finally, the proposed approach is tested using the wind farm benchmark proposed in the context of the wind farm FDI/FTC competition., Peer Reviewed, Award-winning
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

On the relationship between interval observers and invariant sets in fault detection

  • Xu, Feng
  • Stoican, Florin
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Olaru, Sorin
In this paper, the relationship between two settheoretic fault detection (FD) approaches, the interval observerbased and the invariant set-based approaches, is investigated. In FD, interval observers monitor the system dynamic behavior in real time and generates adaptive intervals for system outputs. Invariant sets focus more on steady state behavior of the system rather than the transient behavior. This paper discusses these two approaches, presents the relationship between them and compares them in the FD task. At the end, a numerical example is used to illustrate the relation between these two approaches.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Improved fault detection and isolation strategy using a bank of interval observers

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an improved algorithm for actuator-fault detection and isolation (FDI) using a bank of interval observers is presented, where each interval observer matches one considered system mode. In this approach, interval observers and invariant sets are simultaneously used for FDI. Under a collection of improved FDI conditions, this new algorithm can detect and isolate the considered actuator faults. At the end of this paper, a circuit example is used to illustrate the e ectiveness of the proposed strategy
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization under budgetary constraints

  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Rosich Oliva, Albert
The success of any diagnosis strategy critically depends on the sensors measuring process variables. This paper presents a strategy based on diagnosability maximization for optimally locating sensors in distribution networks. The goal is to characterize and determine the set of sensors that guarantees a maximum degree of diagnosability taking into account a given sensor configuration cardinality constraint. The strategy is based on the structural model of the system under consideration. Structural analysis is a powerful tool for determining diagnosis possibilities and evaluating whether the number and the location of sensors are adequate in order to meet some diagnosis specifications. The proposed approach is successfully applied to leakage detection in a Drinking Water Distribution Network., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Actuator-fault detection and isolation based on interval observers and invariant sets

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes an interval observer-based actuator fault detection and isolation (FDI) approach. An interval observer matching the healthy system mode is designed to monitor the system. When the system is in different modes, state or output interval vectors predicted by the interval observer manifest different dynamical behaviors. To guarantee reliable FDI, a collection of invariant set-based FDI conditions are established. Under these conditions, actuator faults can be accurately detected and isolated during the transition between different modes. At the end, the effectiveness of this proposed approach is presented by using a numerical example.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Combining learning in model space fault diagnosis with data validation/reconstruction: Application to the Barcelona water network

  • Quevedo Casín, Joseba Jokin|||0000-0002-7827-2896
  • Chen, Heran
  • Cugueró Escofet, Miquel Àngel|||0000-0001-9525-1790
  • Tino, Peter
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • García Valverde, Diego
  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Yao, Xin
In this paper, an integrated data validation/reconstruction and fault diagnosis approach is proposed for critical infrastructure systems. The proposed methodology is implemented in a two-stage approach. In the first stage, sensor communication faults are detected and corrected, in order to facilitate a reliable dataset to perform system fault diagnosis in the second stage. On the one hand, sensor validation and reconstruction are based on the combined use of spatial and time series models. Spatial models take advantage of the (mass-balance) relation between different variables in the system, whilst time series models take advantage of the temporal redundancy of the measured variables by means of Holt-Winters time series models. On the other hand, fault diagnosis is based on the learning-in-model-space approach that is implemented by fitting a series of models using a series of signal segments selected with a sliding window. In this way, each signal segment can be represented by one model. To rigorously measure the ‘distance’ between models, the distance in the model space is defined. The deterministic reservoir computing approach is used to approximate a model with the input–output dynamics that exploits spatial–temporal correlations existing in the original data. Finally, the proposed approach is successfully applied to the Barcelona water network., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Adaptive threshold generation in robust fault detection using interval models: Time-domain and frequency-domain approaches

  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Montes de Oca Armeaga, Saul
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
In this paper, robust fault detection is addressed on the basis of evaluating the residual energy that it is compared against worst-case value (threshold) generated considering parametric modeling uncertainty using interval models. The evaluation of the residual/threshold energy can be performed either in the time or frequency domain. This paper proposes methods to compute such energy in the two domains. The first method generates the adaptive threshold in the time domain through determining the worst-case time evolution of the residual energy using a zonotope-based algorithm. The second method evaluates the worstcase energy evolution in the frequency domain using the Kharitonov polynomials. Results obtained using both approaches are related through the Parseval’s theorem. Finally, two application examples (a smart servoactuator and a two DOFs helicopter) will be used to assess the validity of the proposed approaches and compare the results obtained.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

A model for a multiresolution time series database system

  • Llusà Serra, Aleix|||0000-0002-1682-9564
  • Escobet Canal, Teresa|||0000-0001-6090-1538
  • Vila Marta, Sebastià|||0000-0001-9069-1340
In this paper we propose a model for multiresolution time series database management systems. Thismodel stores compactly a time series and manages consistently its temporal dimension. This is achieved byextracting different resolutions and attributes summaries from the original time series. Our work is concerned inputting together two areas of study: time series analysis and database management systems. Time series analysisoffers a great deal of methodologies and algorithms to process time series data. Database systems field providessoftware expertise in managing data. Therefore, for many applications it is of primary relevance that databasesystems support time series., The research presented in this paper has been supported by Spanish research project NASP (TEC2012-35571), SHERECS (DPI2011-26243), the UE project i-Sense (FP7-ICT-270428), and Universitat Politècnica de Catalunya, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

A virtual actuator and sensor approach for fault tolerant control of LPV systems

  • Rotondo, Damiano|||0000-0002-8855-5582
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
In this paper, a fault tolerant control (FTC) strategy using virtual actuators and sensors for linear parameter varying (LPV) systems is proposed. The main idea of this FTC method, initially developed for LTI systems, is to reconfigure the control loop such that the nominal controller could still be used without need of retuning it. The plant with the faulty actuator/sensor is modified adding the virtual actuator/sensor block that masks the actuator/sensor fault. The suggested technique is an active FTC strategy that reconfigures the virtual actuator/sensor on-line taking into account faults and operating point changes. The stability of the reconfigured control loop is guaranteed if the faulty plant is stabilizable/detectable. The LPV virtual actuator/sensor is designed using polytopic LPV techniques and linear matrix inequalities (LMIs). A two-tank system simulator is used to assess the performance of the proposed method. In particular, it is shown that the application of the proposed technique results in an improvement, in terms of performance, with respect to the LTI counterpart, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

A service reliability model predictive control with dynamic safety stocks and actuators health monitoring for drinking water networks

  • Grosso Pérez, Juan Manuel|||0000-0002-4300-1500
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
This paper presents a model predictive control strategy to assure reliability in drinking water networks given a customer service level and a forecasting demand. The underlying idea concerns a two-layer hierarchical control structure. The upper layer performs a local steady-state optimization to set up an inventory replenishment policy based on dynamic safety stocks for each tank in the network. At the same stage, actuators health is revised to set up their next maximum allowable degradation in order to efficiently distribute overall control effort and guarantee system availability. In the lower layer, a model predictive control algorithm is implemented to compute optimal control set-points to minimize a multiobjective cost function. Simulation results in the Barcelona drinking water network have shown the effectiveness of the dynamic safety stocks allocation and the actuators health monitoring to assure service reliability and optimizing network operational costs., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Robust quasi-LPV model reference FTC of a quadrotor UAV subject to actuator faults

  • Rotondo, Damiano|||0000-0002-8855-5582
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
A solution for fault tolerant control (FTC) of a quadrotor unmanned aerial vehicle (UAV) is proposed. It relies on model reference-based control, where a reference model generates the desired trajectory. Depending on the type of reference model used for generating the reference trajectory, and on the assumptions about the availability and uncertainty of fault estimation, different error models are obtained. These error models are suitable for passive FTC, active FTC and hybrid FTC, the latter being able to merge the benefits of active and passive FTC while reducing their respective drawbacks. The controller is generated using results from the robust linear parameter varying (LPV) polytopic framework, where the vector of varying parameters is used to schedule between uncertain linear time invariant (LTI) systems. The design procedure relies on solving a set of linear matrix inequalities (LMIs) in order to achieve regional pole placement and H8 norm bounding constraints. Simulation results are used to compare the different FTC strategies., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization in distribution networks

  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Rosich Oliva, Albert
The success of any diagnosis strategy critically depends on the sensors measuring process variables. This paper presents a strategy based on diagnosability maximization for optimally locating sensors in distribution networks. The goal is to characterize and determine the set of sensors that guarantee a maximum degree of diagnosability taking into account a given sensor configuration cardinality constraint. The strategy is based on the structural model of the system under consideration. Structural analysis is a powerful tool for determining diagnosis possibilities and evaluating whether the number and the location of sensors are adequate in order to meet some diagnosis specifications. The proposed approach is successfully applied to leakage detection in a Drinking Water Distribution Network., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Quasi-LPV modeling, identification and control of a twin rotor MIMO system

  • Rotondo, Damiano|||0000-0002-8855-5582
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
This paper describes the quasi-linear parameter varying (quasi-LPV) modeling, identification and control of a Twin Rotor MIMO System (TRMS). The non-linear model of the TRMS is transformed into a quasi-LPV system and approximated in a polytopic way. The unknown model parameters have been calibrated by means of the non-linear least squares identification approach and validated against real data. Finally, an LPV state observer and state-feedback controller have been designed using an LPV pole placement method based on LMI regions. The effectiveness and performance of the proposed control approach have been proved both in simulation and on the real set-up., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Garza Castañón, Luís Eduardo
  • Rosich, Albert
In this paper, a new approach for sensor placement in water distribution networks (WDN) is proposed. The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the non-linear integer and largescale nature of the resulting optimization problem, genetic algorithms (GA) are used as solution approach. To validate the results obtained, they are compared with exhaustive search methods with higher computational cost proving that GA allow to find near-optimal solutions with less computational load. The proposed sensor placement algorithm is combined with a projection-based isolation scheme. However, the proposed methodology does not depend on the isolation method chosen by the user and it could be easily adapted to any other isolation scheme. Experiments on a real network allow to evaluate the performance of such approach.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Methodology for actuator fault tolerance evaluation of linear constrained MPC: application to the Barcelona water network

  • Robles, Deneb
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Garza Castañón, Luís Eduardo
This paper presents a methodology to evaluate the admissibility of actuator fault configurations (AFC) when Linear Constrained Model Predictive Control (LCMPC) is used. The methodology combines the use of structural and feasability analysis. Structural analysis allows to evaluate the loss of reachability after a fault occurrence. The results of the structural analysis can be complemented with the feasibility analysis of the MPC problem taking into account the effect of actuator constraints after the fault occurrence. Additionally, a degradation analysis of the system performance can also be included. The proposed methodology is tested in the Barcelona water network.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak detection and location in water distribution networks

  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Quevedo Casín, Joseba Jokin|||0000-0002-7827-2896
The performance of a leak detection and location algorithm depends on the set of measurements that are available in the network. This works presents and optimization strategy that maximizes the leak diagnosability performance of the network. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of disnosability while the sensor configuration cost satifies a budgetary constraint. To efficiently handle the complexity of the distribuion networl an efficient branch and bound search strategy based on a strucutrual model is used. However, in order to reduce even more the size and the complexity of the problem the present work proposes to combine this methodology with clustering techniques. The strategy developed in this work is successfully applied to determine the optimal set of pressure sensors that should be installed to a District Metered Area in the Baarcelona Water Distribution Network., Peer Reviewed, Award-winning
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Improved fault detection and isolation strategy using a bank of interval observers

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an improved algorithm for actuator-fault detection and isolation (FDI) using a bank of interval observers is presented, where each interval observer matches one considered system mode. In this approach, interval observers and invariant sets are simultaneously used for FDI. Under a collection of improved FDI conditions, this new algorithm can detect and isolate the considered actuator faults. At the end of this paper, a circuit example is used to illustrate the eectiveness of the proposed strategy.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

A fault-hiding approach for the switching quasi-LPV fault-tolerant control of a four-wheeled omnidirectional mobile robot

  • Rotondo, Damiano|||0000-0002-8855-5582
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Romera Formiguera, Juli
This paper proposes a reference model approach for the trajectory tracking of a four-wheeled omnidirectional mobile robot. In particular, the error model is brought to a quasi-linear-parameter-varying (LPV) form suitable for designing an error-feedback controller. It is shown that, if polytopic techniques are used to reduce the number of constraints from infinite to finite, a solution within the standard LPV framework could not exist due to a singularity that appears in the possible values of the input matrix. Adding a switching component to the controller allows solving this problem. Moreover, a switching LPV virtual actuator is added to the control loop in order to obtain fault tolerance within the fault-hiding paradigm, keeping the stability and some desired performances under the effect of actuator faults without the need of retuning the nominal controller. The effectiveness of the proposed approach is shown and proved through simulation and experimental results., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault detection and Isolation using Interval Observers

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes an interval observer-based sensor fault detection and isolation (FDI) approach for the closed-loop systems. In this proposed approach, residuals are defined in such a way that their components are independent of each other at the time instant after fault occurrence, namely kf + 1, where kf denotes the fault occurrence time instant. In this way, it is guaranteed that at kf + 1 the changes in each component of the residuals are only related to the fault in the corresponding sensor. By detecting the threshold violation of the corresponding residual interval components, the proposed method can detect and isolate sensor faults at that time instant. At the end of this paper, a numerical example is used to present the effectiveness of the approach.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Robust identification and fault diagnosis based on uncertain multiple input-multiple output linear parameter varying parity equations and zonotopes

Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Methodology for actuator fault tolerance evaluation of linear constrained MPC: application to the Barcelona water network

  • Robles, Deneb
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Garza Castañón, Luís Eduardo
This paper presents a methodology to evaluate the admissibility of actuator fault configurations (AFC) when Linear Constrained Model Predictive Control (LCMPC) is used. The methodology combines the use of structural and feasability analysis. Structural analysis allows to evaluate the loss of reachability after a fault occurrence. The results of the structural analysis can be complemented with the feasibility analysis of the MPC problem taking into account the effect of actuator constraints after the fault occurrence. Additionally, a degradation analysis of the system performance can also be included. The proposed methodology is tested in the Barcelona water network., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Fault Diagnosis of a Wind Farm using Interval Parity Equations

  • Blesa Izquierdo, Joaquim
  • Jiménez, P.
  • Rotondo, Damiano
  • Nejjari Akhi-Elarab, Fatiha
  • Puig Cayuela, Vicenç
Segon Premi a la "Competition on Wind Farm Fault Accomodation", atorgat per l'Aalborg University, al 19th. World Congress of the International Federation of Automatic Control, In this paper, the problem of fault diagnosis of a wind farm is addressed using interval parity equations. Fault detection is based on the use of parity equations and unknown but bounded description of the noise and modeling errors. The fault detection test is based on checking the consistency between the measurements and the model by finding if the formers are inside the interval prediction bounds. The fault isolation algorithm is based on analyzing the observed fault signatures on-line, and matching them with the theoretical ones obtained using structural analysis. Finally, the proposed approach is tested using the wind farm benchmark proposed in the context of the wind farm FDI/FTC competition., Peer Reviewed, Award-winning, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Adaptive threshold generation in robust fault detection using interval models: Time-domain and frequency-domain approaches

  • Puig Cayuela, Vicenç
  • Montes de Oca Armeaga, Saul
  • Blesa Izquierdo, Joaquim
In this paper, robust fault detection is addressed on the basis of evaluating the residual energy that it is compared against worst-case value (threshold) generated considering parametric modeling uncertainty using interval models. The evaluation of the residual/threshold energy can be performed either in the time or frequency domain. This paper proposes methods to compute such energy in the two domains. The first method generates the adaptive threshold in the time domain through determining the worst-case time evolution of the residual energy using a zonotope-based algorithm. The second method evaluates the worstcase energy evolution in the frequency domain using the Kharitonov polynomials. Results obtained using both approaches are related through the Parseval’s theorem. Finally, two application examples (a smart servoactuator and a two DOFs helicopter) will be used to assess the validity of the proposed approaches and compare the results obtained., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak detection and location in water distribution networks

  • Sarrate Estruch, Ramon
  • Blesa Izquierdo, Joaquim
  • Nejjari Akhi-Elarab, Fatiha
  • Quevedo Casín, Joseba Jokin
The performance of a leak detection and location algorithm depends on the set of measurements that are available in the network. This works presents and optimization strategy that maximizes the leak diagnosability performance of the network. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of disnosability while the sensor configuration cost satifies a budgetary constraint. To efficiently handle the complexity of the distribuion networl an efficient branch and bound search strategy based on a strucutrual model is used. However, in order to reduce even more the size and the complexity of the problem the present work proposes to combine this methodology with clustering techniques. The strategy developed in this work is successfully applied to determine the optimal set of pressure sensors that should be installed to a District Metered Area in the Baarcelona Water Distribution Network., Peer Reviewed, Award-winning, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Set-theoretic methods in robust detection and isolation of sensor faults

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
  • Stoican, Florin
This paper proposes a sensor-fault detection and isolation (FDI) approach based on interval observers and invariant sets. In fault detection (FD), both interval observer-based and invariant set-based mechanisms are used to provide real-time fault alarms. In fault isolation (FI), the proposed approach also uses these two different mechanisms. The former, based on interval observers, aims to isolate faults during the transient-state operation induced by faults. If the former does not succeed, the latter, based on both interval observers and invariant sets, is started to guarantee FI after the system enters into steady state. Besides, a collection of invariant set-based FDI conditions are established by using all available system-operating information provided by all interval observers. In order to reduce computational complexity, a method to remove all available but redundant/unnecessary system-operating information is incorporated into this approach. If the considered faults satisfy the proposed FDI conditions, it can be guaranteed that they are detectable and isolable after their occurrences. This paper concludes with a case study based on a subsystem of a wind turbine benchmark, which can illustrate the effectiveness of this FDI technique., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Quasi-LPV modeling, identification and control of a twin rotor MIMO system

  • Rotondo, Damiano
  • Nejjari Akhi-Elarab, Fatiha
  • Puig Cayuela, Vicenç
This paper describes the quasi-linear parameter varying (quasi-LPV) modeling, identification and control of a Twin Rotor MIMO System (TRMS). The non-linear model of the TRMS is transformed into a quasi-LPV system and approximated in a polytopic way. The unknown model parameters have been calibrated by means of the non-linear least squares identification approach and validated against real data. Finally, an LPV state observer and state-feedback controller have been designed using an LPV pole placement method based on LMI regions. The effectiveness and performance of the proposed control approach have been proved both in simulation and on the real set-up., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Fault detection and isolation based on the combination of a bank of interval observers and invariant sets

  • Xu, Feng
  • Stoican, Florin
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
In this paper, a fault detection and isolation (FDI) approach using a bank of interval observers is developed. From the methodological point of view, a bank of interval observers is designed according to different dynamical models of the system under different modes (healthy or faulty). Each interval observer matches one system mode while all the interval observers monitor the system simultaneously. In order to guarantee FDI, a set of FDI conditions based on invariant set notions are established. These conditions ensure that the considered faults can be accurately isolated after a period of monitoring time. Finally, simulation results are used to present the effectiveness of the approach., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A virtual actuator and sensor approach for fault tolerant control of LPV systems

  • Rotondo, Damiano
  • Nejjari Akhi-Elarab, Fatiha
  • Puig Cayuela, Vicenç
In this paper, a fault tolerant control (FTC) strategy using virtual actuators and sensors for linear parameter varying (LPV) systems is proposed. The main idea of this FTC method, initially developed for LTI systems, is to reconfigure the control loop such that the nominal controller could still be used without need of retuning it. The plant with the faulty actuator/sensor is modified adding the virtual actuator/sensor block that masks the actuator/sensor fault. The suggested technique is an active FTC strategy that reconfigures the virtual actuator/sensor on-line taking into account faults and operating point changes. The stability of the reconfigured control loop is guaranteed if the faulty plant is stabilizable/detectable. The LPV virtual actuator/sensor is designed using polytopic LPV techniques and linear matrix inequalities (LMIs). A two-tank system simulator is used to assess the performance of the proposed method. In particular, it is shown that the application of the proposed technique results in an improvement, in terms of performance, with respect to the LTI counterpart, Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Model-based optimal sensor placement approaches to fuel cell stack system fault diagnosis

  • Sarrate Estruch, Ramon
  • Nejjari Akhi-Elarab, Fatiha
  • Rosich Oliva, Albert
The problem of optimal sensor placement for FDI consists in d etermining the set of sensors that minimizes a pre-defined cost function satisfying at the same time a pre-established set of FDI specifications for a given set of faults. This paper recalls t hree model-based optimal sensor location approaches: an Incremental search, a Heuristic search and a Binary Integer Linear Programming (BILP) formulation. The main contribution of this paper is a compar ative study that addresses efficiency, flexibility and other issues. The performance of the approac hes is demonstrated by an application to a fuel cell stack system., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

On the relationship between interval observers and invariant sets in fault detection

  • Xu, Feng
  • Stoican, Florin
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
In this paper, the relationship between two settheoretic fault detection (FD) approaches, the interval observerbased and the invariant set-based approaches, is investigated. In FD, interval observers monitor the system dynamic behavior in real time and generates adaptive intervals for system outputs. Invariant sets focus more on steady state behavior of the system rather than the transient behavior. This paper discusses these two approaches, presents the relationship between them and compares them in the FD task. At the end, a numerical example is used to illustrate the relation between these two approaches., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Improved fault detection and isolation strategy using a bank of interval observers

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an improved algorithm for actuator-fault detection and isolation (FDI) using a bank of interval observers is presented, where each interval observer matches one considered system mode. In this approach, interval observers and invariant sets are simultaneously used for FDI. Under a collection of improved FDI conditions, this new algorithm can detect and isolate the considered actuator faults. At the end of this paper, a circuit example is used to illustrate the eectiveness of the proposed strategy., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization under budgetary constraints

  • Sarrate Estruch, Ramon
  • Nejjari Akhi-Elarab, Fatiha
  • Rosich Oliva, Albert
The success of any diagnosis strategy critically depends on the sensors measuring process variables. This paper presents a strategy based on diagnosability maximization for optimally locating sensors in distribution networks. The goal is to characterize and determine the set of sensors that guarantees a maximum degree of diagnosability taking into account a given sensor configuration cardinality constraint. The strategy is based on the structural model of the system under consideration. Structural analysis is a powerful tool for determining diagnosis possibilities and evaluating whether the number and the location of sensors are adequate in order to meet some diagnosis specifications. The proposed approach is successfully applied to leakage detection in a Drinking Water Distribution Network., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault detection and Isolation using Interval Observers

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes an interval observer-based sensor fault detection and isolation (FDI) approach for the closed-loop systems. In this proposed approach, residuals are defined in such a way that their components are independent of each other at the time instant after fault occurrence, namely kf + 1, where kf denotes the fault occurrence time instant. In this way, it is guaranteed that at kf + 1 the changes in each component of the residuals are only related to the fault in the corresponding sensor. By detecting the threshold violation of the corresponding residual interval components, the proposed method can detect and isolate sensor faults at that time instant. At the end of this paper, a numerical example is used to present the effectiveness of the approach., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Actuator-fault detection and isolation based on set-theoretic approaches

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an actuator-fault detection and isolation (FDI) approach is proposed. The FDI approach is based on a bank of interval observers, each of which is designed to match a healthy or faulty system mode. To ensure reliable FDI for all considered actuator faults, a collection of invariant set-based FDI conditions are established for the proposed technique. Under these guaranteed FDI conditions, all the considered faults can be detected and isolated during the transition induced by fault occurrences. Comparing with the existing set-based FDI approaches, the advantage of the proposed technique consists in that it combines the advantages of interval observers in the transient-state functioning and the advantages of invariant sets in the steady-state functioning. This paper is completed with the study of a continuous stirred-tank reactor (CSTR), which illustrates the effectiveness of the proposed method. (C) 2014 Elsevier Ltd. All rights reserved., Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Set-membership identification and fault detection using a Bayesian framework

  • Fernández Canti, Rosa M.
  • Blesa Izquierdo, Joaquim
  • Puig Cayuela, Vicenç
  • Tornil Sin, Sebastián
This paper deals with the problem of set-membership identification and fault detection using a Bayesian framework. The paper presents how the set-membership model estimation problem can be reformulated from the Bayesian viewpoint in order to, first, determine the feasible parameter set in the identification stage and, second, check the consistency between the measurement data and the model in the fault-detection stage. The paper shows that, assuming uniform distributed measurement noise and uniform model prior probability distributions, the Bayesian approach leads to the same feasible parameter set than the well-known set-membership technique based on approximating the feasible parameter set using sets. Additionally, it can deal with models that are nonlinear in the parameters. The single-output and multiple-output cases are addressed as well. The procedure and results are illustrated by means of the application to a quadruple-tank process., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig Cayuela, Vicenç
  • Garza Castañón, Luís Eduardo
  • Rosich, Albert
This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

A service reliability model predictive control with dynamic safety stocks and actuators health monitoring for drinking water networks

  • Grosso Pérez, Juan Manuel
  • Ocampo-Martínez, Carlos
  • Puig Cayuela, Vicenç
This paper presents a model predictive control strategy to assure reliability in drinking water networks given a customer service level and a forecasting demand. The underlying idea concerns a two-layer hierarchical control structure. The upper layer performs a local steady-state optimization to set up an inventory replenishment policy based on dynamic safety stocks for each tank in the network. At the same stage, actuators health is revised to set up their next maximum allowable degradation in order to efficiently distribute overall control effort and guarantee system availability. In the lower layer, a model predictive control algorithm is implemented to compute optimal control set-points to minimize a multiobjective cost function. Simulation results in the Barcelona drinking water network have shown the effectiveness of the dynamic safety stocks allocation and the actuators health monitoring to assure service reliability and optimizing network operational costs., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig Cayuela, Vicenç
  • Garza Castañón, Luís Eduardo
  • Rosich, Albert
In this paper, a new approach for sensor placement in water distribution networks (WDN) is proposed. The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the non-linear integer and largescale nature of the resulting optimization problem, genetic algorithms (GA) are used as solution approach. To validate the results obtained, they are compared with exhaustive search methods with higher computational cost proving that GA allow to find near-optimal solutions with less computational load. The proposed sensor placement algorithm is combined with a projection-based isolation scheme. However, the proposed methodology does not depend on the isolation method chosen by the user and it could be easily adapted to any other isolation scheme. Experiments on a real network allow to evaluate the performance of such approach., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Automated generation and comparison of Takagi–Sugeno and polytopic quasi-LPV models

  • Rotondo, Damiano
  • Puig Cayuela, Vicenç
  • Nejjari Akhi-Elarab, Fatiha
  • Witczak, Marcin
In the last decades, gain-scheduling control techniques have consolidated as an efficient answer to analysis and synthesis problems for non-linear systems. Among the approaches proposed in the literature, the linear parameter varying (LPV) and Takagi–Sugeno (TS) paradigms have proved to be successful in dealing with the different trials that the analyzer, or the designer, of a gain-scheduled control system has to face. Despite the strong similarities between the two paradigms, research on LPV and TS systems has been performed in an independent way and some results that could be useful for both paradigms were obtained only for one of them. However, in recent works, some clues that there is a very close connection between LPV and TS worlds have been presented. The present paper openly addresses the presence of strong analogies between LPV and TS models, in an attempt to establish a bridge between these two worlds, so far considered different. In particular, this paper addresses the modeling problem, presenting two methods for the automated generation of LPV and TS systems, and introducing some measures in order to compare the obtained models. A mathematical example is used to illustrate the proposed methods., Peer Reviewed, Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Robust MPC for actuator-fault tolerance using set-based passive fault detection and active fault isolation

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
  • Niculescu, Silviu-Iulian
In this paper, an actuator fault-tolerant control (FTC) scheme is proposed, which is based on tube-based model predictive control (MPC) and set-theoretic fault detection and isolation (FDI). As a robust MPC technique, tube-based MPC, can effectively deal with system constraints and uncertainties with relatively low computational complexity. Set-based FDI can robustly detect and isolate actuator faults. Here, fault detection (FD) is passive by invariant sets, while fault isolation (FI) is active by tubes. Using the constraint-handling ability of MPC controllers, an active FI approach is implemented. A numerical example illustrates the effectiveness of the proposed approach., Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Combining learning in model space fault diagnosis with data validation/reconstruction: Application to the Barcelona water network

  • Quevedo Casín, Joseba Jokin
  • Chen, Heran
  • Cugueró Escofet, Miquel Àngel
  • Tino, Peter
  • Puig Cayuela, Vicenç
  • García Valverde, Diego
  • Sarrate Estruch, Ramon
  • Yao, Xin
In this paper, an integrated data validation/reconstruction and fault diagnosis approach is proposed for critical infrastructure systems. The proposed methodology is implemented in a two-stage approach. In the first stage, sensor communication faults are detected and corrected, in order to facilitate a reliable dataset to perform system fault diagnosis in the second stage. On the one hand, sensor validation and reconstruction are based on the combined use of spatial and time series models. Spatial models take advantage of the (mass-balance) relation between different variables in the system, whilst time series models take advantage of the temporal redundancy of the measured variables by means of Holt-Winters time series models. On the other hand, fault diagnosis is based on the learning-in-model-space approach that is implemented by fitting a series of models using a series of signal segments selected with a sliding window. In this way, each signal segment can be represented by one model. To rigorously measure the ‘distance’ between models, the distance in the model space is defined. The deterministic reservoir computing approach is used to approximate a model with the input–output dynamics that exploits spatial–temporal correlations existing in the original data. Finally, the proposed approach is successfully applied to the Barcelona water network., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Improved fault detection and isolation strategy using a bank of interval observers

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an improved algorithm for actuator-fault detection and isolation (FDI) using a bank of interval observers is presented, where each interval observer matches one considered system mode. In this approach, interval observers and invariant sets are simultaneously used for FDI. Under a collection of improved FDI conditions, this new algorithm can detect and isolate the considered actuator faults. At the end of this paper, a circuit example is used to illustrate the e ectiveness of the proposed strategy, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization in distribution networks

  • Sarrate Estruch, Ramon
  • Nejjari Akhi-Elarab, Fatiha
  • Rosich Oliva, Albert
The success of any diagnosis strategy critically depends on the sensors measuring process variables. This paper presents a strategy based on diagnosability maximization for optimally locating sensors in distribution networks. The goal is to characterize and determine the set of sensors that guarantee a maximum degree of diagnosability taking into account a given sensor configuration cardinality constraint. The strategy is based on the structural model of the system under consideration. Structural analysis is a powerful tool for determining diagnosis possibilities and evaluating whether the number and the location of sensors are adequate in order to meet some diagnosis specifications. The proposed approach is successfully applied to leakage detection in a Drinking Water Distribution Network., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Robust Fault Detection using Polytope-based Set-membership Consistency Test

  • Blesa Izquierdo, Joaquim
  • Puig Cayuela, Vicenç
  • Saludes Closa, Jordi
This article proposes a robust set-membership fault detection method based on the use of polytopes to bound the parameter uncertainty set. The proposed polytope-based fault detection algorithm is able to handle systems with bounded parameter variation between samples. It is shown that consistency checks indicating faults can be performed in a natural manner with a polytope description of the feasible parameter set.. Finally, an application example is given, which demonstrates how the algorithm works on a simulated process(a four-tank system). A comparison with a zonotope-based faultdetection approach recently proposed in the literature is included., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Non-linear set-membership identification approach based on the Bayesian framework

  • Fernández Canti, Rosa M.
  • Tornil Sin, Sebastián
  • Blesa Izquierdo, Joaquim
  • Puig Cayuela, Vicenç
This study deals with the problem of set-membership identification of non-linear-in-the-parameters models. To solve this problem, this study illustrates how the Bayesian approach can be used to determine the feasible parameter set (FPS) by assuming uniform distributed estimation error and flat model prior probability distributions. The key point of the methodology is the interval evaluation of the likelihood function and the result is a set of boxes with associated credibility indices. For each box, the credibility index is in the interval (0, 1] and gives information about the amount of consistent models inside the box. The union of the boxes with credibility value equal to one provides an inner approximation of the FPS, whereas the union of all boxes provides an outer estimation. The boxes with credibility value smaller than one are located around the boundary of the FPS and their credibility index can be used to iteratively refine the inner and outer approximations up to a desired precision. The main issues and performance of the developed algorithms are discussed and illustrated by means of examples., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Searching force-closure optimal grasps of articulated 2D objects with n links

  • Alvarado Tovar, Noé
  • Suárez Feijóo, Raúl
This paper proposes a method that finds a locally optimal grasp of an articulated 2D object with n links considering frictionless contacts. The surface of each link of the object is represented by a finite set of points, thus it may have any shape. The proposed approach finds, first, an initial force-closure grasp and from it starts an iterative search of a local optimum grasp. The quality measure considered in this work is the largest perturbation wrench that a grasp can resist with independence of the direction of the perturbation. The approach has been implemented and some illustrative examples are included in the article., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

A model for a multiresolution time series database system

  • Llusà Serra, Aleix
  • Escobet Canal, Teresa
  • Vila Marta, Sebastià
In this paper we propose a model for multiresolution time series database management systems. Thismodel stores compactly a time series and manages consistently its temporal dimension. This is achieved byextracting different resolutions and attributes summaries from the original time series. Our work is concerned inputting together two areas of study: time series analysis and database management systems. Time series analysisoffers a great deal of methodologies and algorithms to process time series data. Database systems field providessoftware expertise in managing data. Therefore, for many applications it is of primary relevance that databasesystems support time series., The research presented in this paper has been supported by Spanish research project NASP (TEC2012-35571), SHERECS (DPI2011-26243), the UE project i-Sense (FP7-ICT-270428), and Universitat Politècnica de Catalunya, Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Actuator-fault detection and isolation based on interval observers and invariant sets

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes an interval observer-based actuator fault detection and isolation (FDI) approach. An interval observer matching the healthy system mode is designed to monitor the system. When the system is in different modes, state or output interval vectors predicted by the interval observer manifest different dynamical behaviors. To guarantee reliable FDI, a collection of invariant set-based FDI conditions are established. Under these conditions, actuator faults can be accurately detected and isolated during the transition between different modes. At the end, the effectiveness of this proposed approach is presented by using a numerical example., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Set-membership parity space approach for fault detection in linear uncertain dynamic systems

  • Blesa Izquierdo, Joaquim
  • Puig Cayuela, Vicenç
  • Saludes Closa, Jordi
  • Fernández Canti, Rosa M.
In this paper, a set-membership parity space approach for linear uncertain dynamic systems is proposed. First, a set of parity relations derived from the parity space approach is obtained by means of a transformation derived from the system characteristic polynomial. As a result of this transformation, parity relations can be expressed in regressor form. On the one hand, this facilitates the parameter estimation of those relations using a zonotopic set-membership algorithm. On the other hand, fault detection is then based on checking, at every sample time, the non-existence of a parameter value in the parameter uncertainty set such that the model is consistent with all the system measurements. The proposed approach is applied to two examples: a first illustrative case study based on a two-tank system and a more realistic case study based on the wind turbine fault detection and isolation benchmark in order to evaluate its effectiveness, Peer Reviewed, Postprint (published version)