Aggregation of Type-4 Large Wind Farms Based on Admittance Model Order Reduction

  • Martínez-Turégano, Jaime|||0000-0002-3483-8253
  • Añó Villalba, Salvador Conrado|||0000-0002-8435-5225
  • Bernal-Perez, Soledad|||0000-0002-5431-9792
  • Blasco-Gimenez, Ramon|||0000-0003-3427-1581
[EN] This paper presents an aggregation technique based on the resolution of a multi-objective optimization problem applied to the admittance model of a wind power plant (WPP). The purpose of the presented aggregation technique is to reduce the order of the wind power plant model in order to accelerate WPP simulation while keeping a very similar control performance for both the simplified and the detailed models. The proposed aggregation technique, based on the admittance model order reduction, ensures the same DC gain, the same gain at the operating band frequency, and the same resonant peak frequency as the detailed admittance model. The proposed aggregation method is validated considering three 400-MW grid-forming Type-4 WPPs connected to a diode rectifier HVDC link. The proposed aggregation technique is compared to two existing aggregation techniques, both in terms of frequency and time response. The detailed and aggregated models have been tested using PSCAD-EMTsimulations, with the proposed aggregated model leading to a 350-fold reduction of the simulation time with respect to the detailed model. Moreover, for the considered scenario, the proposed aggregation technique offers simulation errors that are, at least, three-times smaller than previously-published aggregation techniques., The authors would like to thank the support of the Spanish Ministry of Science, Innovation and Universities and EU FEDER funds under Grants DPI2014-53245-R and DPI2017-84503-R. This project has received funding from the European Union's Horizon 2020 research and innovation program under Grant Agreement No. 691714
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Small-signal stability and fault performance of mixed grid forming and grid following offshore wind power plants connected to a HVDC-diode rectifier

  • Martínez-Turégano, Jaime|||0000-0002-3483-8253
  • Añó Villalba, Salvador Conrado|||0000-0002-8435-5225
  • Bernal-Perez, Soledad|||0000-0002-5431-9792
  • Blasco-Gimenez, Ramon|||0000-0003-3427-1581
  • Peña, Rubén
[EN] This study aims at validating the simultaneous operation of grid following and grid forming wind power plants when connected to a common diode rectifier-based HVDC link. The controllers for both grid forming and grid following wind turbines include fault-ride-through capability with soft restoration of the off-shore AC-grid. Current and voltage controllers are developed in the stationary alpha beta reference frame. The presented control and soft restoration strategies are based on local measurements only and do not require communication between wind turbine generators. The small-signal stability analysis of the mixed system in multiple d-q axis using detailed string models is carried out in order to show the sensitivity to grid following phase-locked-loop gains and to grid forming droop gains. Interoperability between grid forming and grid following wind turbines during transients is shown by means of detailed simulation during symmetric faults in different locations of the off-shore grid., The authors would like to thank the support of the Spanish Ministry of Economy and EU FEDER funds under grants DPI2014-53245-R and DPI2017-84503-R. This project has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement No. 691714. Project partially funded by the EU through the Comunitat Valenciana2014-2020 European Regional Development Fund (FEDER) OperatingProgram (grant IDIFEDER/2018/036). The support provided by Fondecyt project 1201616 and CONICYT/FONDAP/1511001 is kindly acknowledged. ANID support through grant ANID/FONDAP/15110019 is kindly acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Stability analysis of multi-terminal HVDC with diode rectifier connected off- shore wind power plants

  • Bernal-Perez, Soledad|||0000-0002-5431-9792
  • Añó Villalba, Salvador Conrado|||0000-0002-8435-5225
  • Blasco-Gimenez, Ramon|||0000-0003-3427-1581
[EN] This paper addresses the detailed modeling and small-signal stability analysis of a multi-terminal high voltage direct current (HVDC) system including a large diode rectifier-connected off-shore wind power plant (WPP). The study covers both islanded and connected WPP operation with different control scenarios. Islanded WPP stands for non-conducting HVDC diode rectifier (DR) whereas in connected WPP operation the DR is conducting. The study of both modes is important as the WPP would be in one of these modes during normal operation. Variable off-shore ac-grid frequency and a dynamic diode rectifier model have been considered for adequate dynamic modeling. The proposed models have been validated against detailed PSCAD EMT simulations and have been used to carry out the small-signal stability analysis of the islanded and connected WPP with different scenarios. Moreover, the dynamic model is used to assess the system robustness against parametric uncertainties, communication delay and power level, ensuring the integration of the off-shore WPP into the on-shore electrical power system. This study also points out that adequate droop control of the HVDC grid has a larger impact on overall stability than the diode rectifier connected off-shore WPP controllers., This work was supported by the Spanish Ministry of Economy and EU FEDER Funds under grants DPI2014-53245-R, and DPI2017-84503-R. This project has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement No. 691714.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Long Term Partial Discharge Behavior of Protrusion Defect in HVDC GIS

  • Vu, Cong-Thanh
  • Toigo, Caterina
  • Jacquier, Frank
  • Girodet, Alain
  • Riechert, Uwe
  • Tuczek, Maximilian Nikolaus
  • Rodrigo Mor, Armando|||0000-0002-5719-8201
[EN] This article investigates the partial discharge (PD) behavior of protrusion defects in real-size high-voltage direct current gas insulated switchgear (HVDC GIS) for SF6 and SF6 alternative gases including fluoronitrile-CO2 mixture (10%) and fluoroketone-dry air mixture (6.6%). The evolution of PD apparent charge and PD repetition rate for all investigated gases is presented and discussed. The measurement results indicate that PD behavior changes as a function of time. The PD apparent charge increases and the PD repetition rate decreases with the increase of voltage application time. This evolution can be related to the change in protrusion tip radius due to electrochemical etching: radius of the protrusion's tip being enlarged. In addition, the pulse sequence analysis (PSA) plots of the PDs caused by this defect are presented. It is observed that the PSA plots change over time. Therefore, for the development of a robust PD monitoring and defect-recognition tool, as well as for the assessment of risks in the operation of HVDC GIS, it is crucial to take these changes into account., This work was supported in part by the Horizon 2020 Progress on Meshed HVDC Offshore Transmission Networks (PROMOTioN) Project under Grant 691714 and in part by the French Government through the frame of "Investissements d'avenir," under Grant ANE-ITE-002-01.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Protection Strategies for the Connection of Diode Rectifier-based Wind Power Plants to HVDC Interconnectors

  • Martínez-Turégano, Jaime|||0000-0002-3483-8253
  • Añó Villalba, Salvador Conrado|||0000-0002-8435-5225
  • Bernal-Perez, Soledad|||0000-0002-5431-9792
  • Blasco-Gimenez, Ramon|||0000-0003-3427-1581
  • Vidal-Albalate, Ricardo
[EN] The connection of diode rectifier (DR) based wind power plants to existing or planned High Voltage dc (HVdc) interconnectors can lead to important savings on cost and system robustness. Since the DR station usually operates in a bipolar configuration, its connection to symmetric monopoles is particularly challenging. However, there are no published detailed studies on the protection of DR connection wind power plants to symmetric monopole interconnectors or even to bipolar interconnectors. This paper includes the comparative study of five different protection strategies for such systems, including both solid and resistive DR station grounding and strategies with and without the use of dc-circuit breakers. An analytical study allows for the calculation of fault current during fault on-set for both half-bridge and hybrid Modular Multi-level Converter (MMC) stations. Using detailed Electromagnetic Transient (EMT) simulation studies, the different protection strategies are evaluated in terms of current, voltage and isolation requirements of each element, as well as the need for dc-circuit breakers, fast communication or larger surge arresters. Moreover, a distance fault detection algorithm is included for the wind turbine converters to distinguish between local ac-grid and dc-cable faults. From the simulation results it is possible to conclude that DR high impedance grounding, together with wind turbine distance protection can be used for the protection of DR based off-shore wind power plants connected to symmetric monopole interconnectors without requiring dc-circuit breakers., This work was supported in part by the Spanish Ministry of Economy and EU FEDER Funds under Grant DPI2017-84503-R, in part by the EU through the Comunitat Valenciana 2014-2020 European Regional Development Fund (FEDER) Operating Program under Grant IDIFEDER/2018/036, and in part by the European Union's Horizon 2020 Research and Innovation Program under Grant Agreement 691714.