Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Preparing for future e-waste from photovoltaic modules: a circular economy approach

  • Hidalgo-Carvajal, David
  • Carrasco-Gallego, Ruth
[EN] The increasing adoption rate of photovoltaic power generation shows that renewable energies have a bright future. Yet, this could be overshadowed by the unintended consequence of increased generation of Waste of Electric and Electronic Equipment (WEEE) at the installations End-of-Life (EoL) stage. As countries find themselves dealing with the increasing WEEE issue, they may adopt different practices which, if wrongly implemented, could potentially backfire, creating additional issues especially among vulnerable social groups. This work proposes improving the WEEE management system by including the Informal Recyclers in the equation, benefitting social groups and material recovery through by delivering materials along different streams in the closed-loop supply chain. The proposed model intends to support the circular economy approach on waste management systems., The authors would like to thank the Instituto Brasileiro de Desenvolvimento e Sustentabilidade (IABS) for their interest and support on our research. Additionally, we would like to thank the projects funding David Hidalgo-Carvajal’s research: the WEDISTRICT project [founded by the European Union’s Horizon 2020 research and innovation programme under grant agreement N°857801], the “Campus UPM Circulares” project within the UPM Research Program [Programa Propio UPM 2020. Acción Estratégica en Ciencia y Tecnología], and “The Circular and Regenerative Campus” community from the EELISA European University Alliance.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Experimental energy performance assessment of a solar desiccant cooling system in Southern Europe climates

  • Comino Montilla, Francisco
  • Castillo González, J.
  • Navas-Martos, F.J.
  • Ruiz de Adana, Manuel
Solar desiccant cooling systems, SDEC, could be an effective alternative to conventional cooling systems, which mainly depend on electrical energy. The main objective of this work was to determine experimentally the seasonal coefficient of performance, SCOP, of a SDEC system composed of a desiccant wheel, an indirect evaporative cooler and a thermal solar system, to control indoor conditions in a research lab room. The dependence of coefficient of performance on outdoor air conditions and percentage of renewable energy used by the SDEC system were also analysed. Experimental tests were carried out for six weeks during spring and summer seasons in Martos, Spain. The experimental results showed that the SDEC system independently adjusted the temperature and humidity of the supply air. 75% of the energy consumed by this air handling system comes from renewable sources. A seasonal coefficient of performance of the SDEC system of 2 was obtained for the period analysed. It is shown that the higher the outdoor temperature, the higher instantaneous COPs is. These results suggest that the use of SDEC systems in hot climates, such as southern European climates, could contribute to achieve the EU's energy goals within the frame of Nearly Zero Energy Buildings.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Detailed experimental analysis of the energy performance of a desiccant wheel activated at low temperature

  • Comino Montilla, Francisco
  • Táboas, Francisco
  • Peci López, Fernando
  • Ruiz de Adana, Manuel
Desiccant dehumidification systems, such as those using desiccant wheels (DW), are an interesting alternative toconventional dehumidification systems based on vapor-compression cycles. The aim of this work was to obtainexperimentally the performance of a DW activated at low temperature along the heat and mass transfer surfaceunder different working conditions. The air temperature and humidity were measured at 32 different points, inorder to analyse the performance of the DW at different circular sectors of the rotor.The results showed that the surface temperatures of the desiccant material on the process side decreasedwhen the rotation speed decreased. Conversely, the surface temperatures of the desiccant material on the re-generation side increased when the rotation speed decreased.The minimum outlet process air temperatures and the maximum process air dehumidification were obtainedin the circular sector closest to the regeneration side. In this circular sector the highest efficiency values wereobtained. The number of circular sectors where the highest efficiency values were obtained increased when therotation speed or airflow rates increased. Using these data, the wheel control strategy could be designed toincrease the dehumidification capacity.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Seasonal Analysis Comparison of Three Air-Cooling Systems in Terms of Thermal Comfort, Air Quality and Energy Consumption for School Buildings in Mediterranean Climates

  • Romero-Lara, María Jesús
  • Comino Montilla, Francisco
  • Ruiz de Adana, Manuel
Efficient air-cooling systems for hot climatic conditions, such as Southern Europe, are required in the context of nearly Zero Energy Buildings, nZEB. Innovative air-cooling systems such as regenerative indirect evaporative coolers, RIEC and desiccant regenerative indirect evaporative coolers, DRIEC, can be considered an interesting alternative to direct expansion air-cooling systems, DX. The main aim of the present work was to evaluate the seasonal performance of three air-cooling systems in terms of air quality, thermal comfort and energy consumption in a standard classroom. Several annual energy simulations were carried out to evaluate these indexes for four different climate zones in the Mediterranean area. The simulations were carried out with empirically validated models. The results showed that DRIEC and DX improved by 29.8% and 14.6% over RIEC regarding thermal comfort, for the warmest climatic conditions, Lampedusa and Seville. However, DX showed an energy consumption three and four times higher than DRIEC for these climatic conditions, respectively. RIEC provided the highest percentage of hours with favorable indoor air quality for all climate zones, between 46.3% and 67.5%. Therefore, the air-cooling systems DRIEC and RIEC have a significant potential to reduce energy consumption, achieving the user’s thermal comfort and improving indoor air quality.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Life cycle assessment of an experimental solar HVAC system and a conventional HVAC system

  • Castillo González, J.
  • Comino Montilla, Francisco
  • Navas-Martos, F.J.
  • Ruiz de Adana, Manuel
Solar heating ventilating air conditioning systems are useful tools to meet the objectives of the European Commission in terms of sustainability in buildings, since their use can reduce the environmental impact, including CO2 emissions, due to their low energy consumption. In order to quantify the improvement that in environmental terms the use of this type of system could entail, in this work it was carried out (a) a comparative life cycle assessment of a solar heating ventilating air conditioningsystem based on vaporative ooling and desiccant wheel with a conventional direct expansion system; and (b) an analysis of feasible modifications of the desiccant wheel based system and their influence on the life cycle analysis results. The experimental desiccant wheel based system showed a slightly higher environmental performance than the conventional direct expansion based system, between 2% and 10%, for the 3 impact categories evaluated: human health, ecosystem quality and resource consumption. When weight optimisation and the reuse of materials were considered, the environmental performance of the experimental based system became even up to between 22% and 50% higher than that of the conventional direct expansion based system. That involved a 60 % reduction in climate change potential indicator, which mainly was influenced by CO2 emissions.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Development of Innovative Thermoplastic Foam Materials Using Two Additive Manufacturing Technologies for Application in Evaporative Cooling Systems

  • Castillo González, J.
  • Comino Montilla, Francisco
  • Caruana, Roberta
  • Guilizzoni, Manfredo
  • Conrat, Paula
  • Ruiz de Adana, Manuel
  • Navas-Martos, F.J.
Evaporative cooling systems have emerged as low-energy consumption alternatives to traditional vapor compression systems for building air conditioning. This study explored the feasibility of utilizing polymeric foamed materials produced through additive manufacturing as wetting materials in evaporative cooling systems. Specifically, two different commercial polylactic acid filaments, each containing a percentage of a chemical blowing agent, were studied. Experiments were designed to evaluate the influence of critical process parameters (line width, flow rate, speed, and layer height) on the performance of the resulting foamed materials in terms of evaporative cooling by conducting water absorption, capillarity, porosity, and wettability tests. Considering that high water absorption, capillarity, and porosity, coupled with an intermediate contact angle, are advantageous for evaporative cooling effectiveness, a low flow rate was found to be the most important parameter to improve these properties’ values. The results showed that the appropriate combination of polymer and process parameters allowed the production of foamed polymer-based materials processed by additive manufacturing technology with optimal performance.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Enhanced evaporative cooling using additively manufactured PLA–wood composite lattices

  • Conrat, Paula
  • Comino Montilla, Francisco
  • Caruana, Roberta
  • Guilizzoni, Manfredo
  • Romero, Pablo E.
  • Ruiz de Adana, Manuel
Evaporative cooling technologies are increasingly recognized as energy-efficient and sustainable alternatives to conventional air-conditioning systems. In this study, five evaporative cooling pads, four with lattice geometries and one conventional grid-type reference pad, were designed and fabricated through additive manufacturing using a polilactic acid (PLA)-wood composite, then characterized and experimentally evaluated under controlled inlet air conditions. Material characterization revealed a rough mesoporous morphology and intermediate wettability, favouring capillary-driven water retention. Among the tested designs, the octagonal lattice geometry exhibited the largest air–water contact surface, achieving the greatest temperature drop (19.7 °C) and wet bulb effectiveness (0.93), thereby demonstrating superior performance. This geometry was subsequently scaled up into a full-scale prototype incorporating an integrated water distribution system. Statistical analysis confirmed that both inlet air temperature and airflow rate had a significant effect on cooling performance, with coefficients of determination above 0.98. The energy analysis of the prototype showed that the cooling capacity increased up to 800 W, while the energy efficiency ratio ranged between 7 and 87 depending on operating conditions. The findings emphasize the strong connection between material properties, lattice geometry, and energy performance, supporting this design to optimize sustainable evaporative cooling systems for building applications.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Experimental energy and water performance of a renewable air-cooling unit under summer and heatwave conditions in Southern Europe

  • Romero-Lara, María Jesús
  • Ruiz de Adana, Manuel
Conventional air-cooling systems accounting for nearly 50% of the electricity consumption of buildings. Space cooling demand is rapidly increasing in warm regions, where this type of systems suffer from efficiency degradation under extreme outdoor conditions. In addition, long-term experimental evidence on the real performance of hybrid air-cooling technologies during heat extreme events remains scarce. The main objective of this work is to experimentally investigate the energy performance and water consumption of a renewable air-cooling unit based on desiccant cooling (“renewable” denotes the system’s design intent and potential, rather than the energy source applied in the present work). This system, comprising a desiccant wheel and a dew-point indirect evaporative cooler, enables independent control of supply air temperature, humidity, and carbon dioxide levels through adjustable operating modes. Daily tests are conducted over 11 weeks in summer 2022 in Cordoba, Spain (Southern Europe), providing long-term data covering 30 representative heat extreme days. Instantaneous system behaviour is evaluated focusing on supply air and energy balances, while seasonal performance is assessed through daily coefficients for thermal and electrical energy performance and water consumption. The highest sensible and latent cooling energies achieved are 87.3 kWh/day and 37.4 kWh/day, respectively, under severe outdoor conditions. Total daily coefficient of performance reaches up to 15.6 due to high cooling capacity and low electrical consumption, while daily water efficiency reaches 0.55 kWh of cooling per litre. These results provide a reference for the feasibility of hybrid air-cooling systems under real-world heat events and climate change scenarios.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Experimental and numerical analysis of the thermal behaviour of a single-phase immersion-cooled data centre

  • Taddeo, Paolo
  • Romaní Picas, Joaquim
  • Summers, Jon
  • Martorell, Ingrid
  • Salom, Jaume
Server power densities are foreseen to increase, and conventional air-cooling systems will struggle to cope with thermal demand. Single-phase immersion systems are a promising alternative to operate very intensive workload such as high-performance computing, cryptocurrencies mining or research activities. However, few companies deal with this kind of system and there is a lack of energy models that can reproduce an accurate analysis of the system behaviour. This study addresses the experimentation, data collection, and model validation of a singlephase immersion cooling system where 54 open compute project servers, each with a peak power of 400 Watts that are submerged and operated in a dielectric coolant. Results show the evolution of the thermal profile of the system under static and dynamic workloads, and it provides a correlation of server energy use under various system temperatures. The energy model is presented, validated against real data, and exploited to investigate the system response to different cooling conditions. In conclusion, the study demonstrates the validation of the energy model and supports the basis for further investigation., This work has received funding from the European Union H2020 Framework Programme under Grant Agreement no. 857801 (WEDISTRICT). IREC authors would like to thank Generalitat de Catalunya for the project grant given to their research group (2021 SGR 01403). Ingrid Martorell would like to thank Generalitat de Catalunya for the project grant given to her research group (2021 SGR 01370).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Experimental and numerical analysis of the thermal behaviour of a single-phase immersion-cooled data centre

  • Taddeo, Paolo
  • Romaní Picas, Joaquim
  • Summers, Jon
  • Martorell, Ingrid
  • Salom, Jaume
Server power densities are foreseen to increase, and conventional air-cooling systems will struggle to cope with thermal demand. Single-phase immersion systems are a promising alternative to operate very intensive workload such as high-performance computing, cryptocurrencies mining or research activities. However, few companies deal with this kind of system and there is a lack of energy models that can reproduce an accurate analysis of the system behaviour. This study addresses the experimentation, data collection, and model validation of a singlephase immersion cooling system where 54 open compute project servers, each with a peak power of 400 Watts that are submerged and operated in a dielectric coolant. Results show the evolution of the thermal profile of the system under static and dynamic workloads, and it provides a correlation of server energy use under various system temperatures. The energy model is presented, validated against real data, and exploited to investigate the system response to different cooling conditions. In conclusion, the study demonstrates the validation of the energy model and supports the basis for further investigation., This work has received funding from the European Union H2020 Framework Programme under Grant Agreement no. 857801 (WEDISTRICT). IREC authors would like to thank Generalitat de Catalunya for the project grant given to their research group (2021 SGR 01403). Ingrid Martorell would like to thank Generalitat de Catalunya for the project grant given to her research group (2021 SGR 01370).
Archivo Digital UPM
Publicación Artículo científico (JournalArticle)

Comprehensive analysis of hot water tank sizing for a hybrid solar-biomass district heating and cooling

  • Roncal Casano, Juan José|||0000-0003-1835-1303
  • Rodríguez Martín, Javier|||0000-0003-1451-0856
  • Abánades Velasco, Alberto|||0000-0003-0179-5987
  • Muñoz Antón, Javier|||0000-0002-1980-0863
  • Gurruchaga, Ignasi
  • González Castellví, Daniell
Archivo Digital UPM
Publicación Artículo científico (JournalArticle)

Proposal of a thermocline molten salt storage tank for district heating and cooling

  • Abánades Velasco, Alberto|||0000-0003-0179-5987
  • Rodríguez Martín, Javier|||0000-0003-1451-0856
  • Roncal Casano, Juan José|||0000-0003-1835-1303
  • Caraballo, Adrián
  • Galindo, Francisca
Archivo Digital UPM
Publicación Artículo científico (JournalArticle)

Recycled PLA for 3D Printing: A Comparison of Recycled PLA Filaments from Waste of Different Origins after Repeated Cycles of Extrusion

  • Hidalgo Carvajal, David|||0000-0001-7771-0906
  • Hortal Muñoz, Álvaro
  • Garrido González, José J.|||0000-0001-7696-7902
  • Carrasco Gallego, Ruth|||0000-0002-9542-3836
  • Alcázar Montero, María Victoria|||0000-0002-1891-3209
Archivo Digital UPM
Publicación Artículo científico (JournalArticle)

Environmental and Social Life Cycle Assessment of Data Centre Heat Recovery Technologies Combined with Fuel Cells for Energy Generation

  • Puentes Bejarano, Camila Andrea
  • Pérez Rodríguez, Javier|||0000-0002-3896-621X
  • Andrés Almeida, Juan Manuel de|||0000-0002-0654-5496
  • Hidalgo Carvajal, David|||0000-0001-7771-0906
  • Gustaffsson, Jonas|||0000-0002-9759-5594
  • Summers, Jon|||0000-0001-8266-5038
  • Abánades Velasco, Alberto|||0000-0003-0179-5987
Archivo Digital UPM
Publicación Artículo científico (JournalArticle)

Environmental and Social Impacts of Renewable Energy-Driven Centralized Heating/Cooling Systems: A Comparison with Conventional Fossil Fuel-Based Systems

  • Pérez Rodríguez, Javier|||0000-0002-3896-621X
  • Hidalgo Carvajal, David|||0000-0001-7771-0906
  • Andrés Almeida, Juan Manuel de|||0000-0002-0654-5496
  • Abánades Velasco, Alberto|||0000-0003-0179-5987