Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 21
Encontrada(s) 1 página(s)

TECNALIA Publications
Publicación Contribución de congreso (ConferenceOutput)

Integration of Renewables in DHC for Sustainable Living Workshop

  • Vázquez, María Victoria Cambronero
  • Corscadden, Jack
  • Marijuan, Antonio Garrido
  • Barbagelata, Giulia
  • Hamann, Georg
  • Grosjean, Matthieu
  • Mendoza, Nora
There is a large potential to integrate substantial shares of renewable energy and waste heat sources in district heating and/or cooling networks (DHC), reducing dependency of DHC on fossil fuels and ultimately leading to a more efficient and sustainable energy system. Several EU funded projects are currently working on this topic. The objective of the workshop aimed to share the WEDISTRICT project concept with other sister projects and interested stakeholders in order to exchange new ideas, lessons learnt from implementation and proposals about the successful integration of renewable technologies in DHC and urban regeneration.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Introduciendo los ODS y la circularidad a la educación en ingeniería a través de actividades para el reciclado de plásticos en un campus universitario

  • Agüero Rodríguez, Ángel
  • Hidalgo-Carvajal, David
  • Lascano, Diego
  • Sepúlveda, Javiera
  • Arrieta, Marina Patricia
  • Carrasco-Gallego, Ruth
  • M. Muneta, María Luisa
[ES] Atendiendo a la vinculación directa de los objetivos de desarrollo sostenible (ODS) con el mundo ingenieril, en este trabajo se plantea una actividad docente centrada en fomentar la economía circular de la Escuela Técnica Superior de Ingenieros Industriales de la Universidad Politécnica de Madrid, mediante la revalorización de residuos plásticos generados en la Escuela mediante reciclado mecánico. La actividad consiste en la fabricación de filamento 3D empleando residuos de piezas impresas defectuosas que han sido fabricadas en la escuela utilizando un plástico biobasado y biodegradable, el poli(ácido láctico) (PLA), para la generación de nuevos productos por impresión 3D y, posteriormente, comprobar la compostabilidad de dichos productos demostrando que se integran completamente en la economía circular. Los estudiantes conocen de primera mano un entorno FabLab y un Living Lab, ejemplos de innovación educativa que sirven como escenarios perfectos para el desarrollo de ofertas formativas orientadas a la implementación de los ODS. Así, se demuestran la importancia de integrar los ODS en la educación superior y la relevancia de involucrar a los estudiantes en el proceso de aprendizaje activo en espacios comunes de trabajo que fomentan el sentido de autoeficacia y facilitan la adquisición y retención de conocimiento en el proceso educativo., [EN] Due to the strong relationship between the Sustainable Development Goals (SDGs) and the engineering world, this paper proposes a teaching activity focused on promoting the circular economy of the Higher Technical School of Industrial Engineers of the Polytechnic University of Madrid (ETSII-UPM) through the revaluation of plastic waste, which it was generated at the School. This revaluation consists of mechanical recycling to manufacture 3D filament using waste from defective printed parts that have been produced at the school. This activity is focused on a biobased and biodegradable plastic, poly(lactic acid) (PLA), for the generation of new products by 3D printing and, subsequently, corroborating its compostability. This represents a good demonstration of the full integration of the circular economy in a productive process. Students get to know first-hand a FabLab and Living Lab environment, which are examples of educational innovation that serve as a perfect frame for development training offers aimed at implementing the SDGs. Thus, the importance of integrating the SDGs in higher education, and the relevance of involving students in the active learning process in common workspaces, which foster a sense of self-efficacy and facilitate the acquisition and retention of knowledge in the educative process, are demonstrated., Este trabajo es parte de los proyectos de I+D+i PID2021-123753NA-C32 y TED2021-129920A-C43, financiado por MCIN/AEI/10.13039/501100011033 así como también por “FEDER Una manera de hacer Europa” y por la “Unión Europea NextGenerationEU/PRTR”, respectivamente. Ángel Agüero Rodríguez y Diego Lascano agradecen su contrato postdoctoral Margarita Salas con la Universitat Politècnica de València, financiado, a través del Ministerio de Universidades, por la Unión Europea-Next generation EU. Javiera Sepúlveda agradece al proyecto de la Universidad Politécnica de Madrid “SDGine for Healthy People and Cities” el cual ha recibido financiación del Programa de Investigación e Innovación Horizonte 2020 de la Unión Europea en el marco del acuerdo de subvención Marie Skłodowska-Curie No 945139 y de ECOEMBALAJES ESPAÑA, S.A. (Ecoembes). David Hidalgo-Carvajal agradece al proyecto WEDISTRICT financiado por el programa de investigación e innovación Horizon 2020 de la Unión Europea con acuerdo N°857801 y al proyecto de investigación “Campus UPM Circulares” de la Universidad Politécnica de Madrid. Finalmente, los autores recalcan que este trabajo es parte de la comunidad “The Circular and Regenerative Campus” perteneciente a la comunidad EELISA European University Alliance.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Preparing for future e-waste from photovoltaic modules: a circular economy approach

  • Hidalgo-Carvajal, David
  • Carrasco-Gallego, Ruth
[EN] The increasing adoption rate of photovoltaic power generation shows that renewable energies have a bright future. Yet, this could be overshadowed by the unintended consequence of increased generation of Waste of Electric and Electronic Equipment (WEEE) at the installations End-of-Life (EoL) stage. As countries find themselves dealing with the increasing WEEE issue, they may adopt different practices which, if wrongly implemented, could potentially backfire, creating additional issues especially among vulnerable social groups. This work proposes improving the WEEE management system by including the Informal Recyclers in the equation, benefitting social groups and material recovery through by delivering materials along different streams in the closed-loop supply chain. The proposed model intends to support the circular economy approach on waste management systems., The authors would like to thank the Instituto Brasileiro de Desenvolvimento e Sustentabilidade (IABS) for their interest and support on our research. Additionally, we would like to thank the projects funding David Hidalgo-Carvajal’s research: the WEDISTRICT project [founded by the European Union’s Horizon 2020 research and innovation programme under grant agreement N°857801], the “Campus UPM Circulares” project within the UPM Research Program [Programa Propio UPM 2020. Acción Estratégica en Ciencia y Tecnología], and “The Circular and Regenerative Campus” community from the EELISA European University Alliance.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Experimental energy performance assessment of a solar desiccant cooling system in Southern Europe climates

  • Comino Montilla, Francisco
  • Castillo González, J.
  • Navas-Martos, F.J.
  • Ruiz de Adana, Manuel
Solar desiccant cooling systems, SDEC, could be an effective alternative to conventional cooling systems, which mainly depend on electrical energy. The main objective of this work was to determine experimentally the seasonal coefficient of performance, SCOP, of a SDEC system composed of a desiccant wheel, an indirect evaporative cooler and a thermal solar system, to control indoor conditions in a research lab room. The dependence of coefficient of performance on outdoor air conditions and percentage of renewable energy used by the SDEC system were also analysed. Experimental tests were carried out for six weeks during spring and summer seasons in Martos, Spain. The experimental results showed that the SDEC system independently adjusted the temperature and humidity of the supply air. 75% of the energy consumed by this air handling system comes from renewable sources. A seasonal coefficient of performance of the SDEC system of 2 was obtained for the period analysed. It is shown that the higher the outdoor temperature, the higher instantaneous COPs is. These results suggest that the use of SDEC systems in hot climates, such as southern European climates, could contribute to achieve the EU's energy goals within the frame of Nearly Zero Energy Buildings.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Detailed experimental analysis of the energy performance of a desiccant wheel activated at low temperature

  • Comino Montilla, Francisco
  • Táboas, Francisco
  • Peci López, Fernando
  • Ruiz de Adana, Manuel
Desiccant dehumidification systems, such as those using desiccant wheels (DW), are an interesting alternative toconventional dehumidification systems based on vapor-compression cycles. The aim of this work was to obtainexperimentally the performance of a DW activated at low temperature along the heat and mass transfer surfaceunder different working conditions. The air temperature and humidity were measured at 32 different points, inorder to analyse the performance of the DW at different circular sectors of the rotor.The results showed that the surface temperatures of the desiccant material on the process side decreasedwhen the rotation speed decreased. Conversely, the surface temperatures of the desiccant material on the re-generation side increased when the rotation speed decreased.The minimum outlet process air temperatures and the maximum process air dehumidification were obtainedin the circular sector closest to the regeneration side. In this circular sector the highest efficiency values wereobtained. The number of circular sectors where the highest efficiency values were obtained increased when therotation speed or airflow rates increased. Using these data, the wheel control strategy could be designed toincrease the dehumidification capacity.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Seasonal Analysis Comparison of Three Air-Cooling Systems in Terms of Thermal Comfort, Air Quality and Energy Consumption for School Buildings in Mediterranean Climates

  • Romero-Lara, María Jesús
  • Comino Montilla, Francisco
  • Ruiz de Adana, Manuel
Efficient air-cooling systems for hot climatic conditions, such as Southern Europe, are required in the context of nearly Zero Energy Buildings, nZEB. Innovative air-cooling systems such as regenerative indirect evaporative coolers, RIEC and desiccant regenerative indirect evaporative coolers, DRIEC, can be considered an interesting alternative to direct expansion air-cooling systems, DX. The main aim of the present work was to evaluate the seasonal performance of three air-cooling systems in terms of air quality, thermal comfort and energy consumption in a standard classroom. Several annual energy simulations were carried out to evaluate these indexes for four different climate zones in the Mediterranean area. The simulations were carried out with empirically validated models. The results showed that DRIEC and DX improved by 29.8% and 14.6% over RIEC regarding thermal comfort, for the warmest climatic conditions, Lampedusa and Seville. However, DX showed an energy consumption three and four times higher than DRIEC for these climatic conditions, respectively. RIEC provided the highest percentage of hours with favorable indoor air quality for all climate zones, between 46.3% and 67.5%. Therefore, the air-cooling systems DRIEC and RIEC have a significant potential to reduce energy consumption, achieving the user’s thermal comfort and improving indoor air quality.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Life cycle assessment of an experimental solar HVAC system and a conventional HVAC system

  • Castillo González, J.
  • Comino Montilla, Francisco
  • Navas-Martos, F.J.
  • Ruiz de Adana, Manuel
Solar heating ventilating air conditioning systems are useful tools to meet the objectives of the European Commission in terms of sustainability in buildings, since their use can reduce the environmental impact, including CO2 emissions, due to their low energy consumption. In order to quantify the improvement that in environmental terms the use of this type of system could entail, in this work it was carried out (a) a comparative life cycle assessment of a solar heating ventilating air conditioningsystem based on vaporative ooling and desiccant wheel with a conventional direct expansion system; and (b) an analysis of feasible modifications of the desiccant wheel based system and their influence on the life cycle analysis results. The experimental desiccant wheel based system showed a slightly higher environmental performance than the conventional direct expansion based system, between 2% and 10%, for the 3 impact categories evaluated: human health, ecosystem quality and resource consumption. When weight optimisation and the reuse of materials were considered, the environmental performance of the experimental based system became even up to between 22% and 50% higher than that of the conventional direct expansion based system. That involved a 60 % reduction in climate change potential indicator, which mainly was influenced by CO2 emissions.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Development of Innovative Thermoplastic Foam Materials Using Two Additive Manufacturing Technologies for Application in Evaporative Cooling Systems

  • Castillo González, J.
  • Comino Montilla, Francisco
  • Caruana, Roberta
  • Guilizzoni, Manfredo
  • Conrat, Paula
  • Ruiz de Adana, Manuel
  • Navas-Martos, F.J.
Evaporative cooling systems have emerged as low-energy consumption alternatives to traditional vapor compression systems for building air conditioning. This study explored the feasibility of utilizing polymeric foamed materials produced through additive manufacturing as wetting materials in evaporative cooling systems. Specifically, two different commercial polylactic acid filaments, each containing a percentage of a chemical blowing agent, were studied. Experiments were designed to evaluate the influence of critical process parameters (line width, flow rate, speed, and layer height) on the performance of the resulting foamed materials in terms of evaporative cooling by conducting water absorption, capillarity, porosity, and wettability tests. Considering that high water absorption, capillarity, and porosity, coupled with an intermediate contact angle, are advantageous for evaporative cooling effectiveness, a low flow rate was found to be the most important parameter to improve these properties’ values. The results showed that the appropriate combination of polymer and process parameters allowed the production of foamed polymer-based materials processed by additive manufacturing technology with optimal performance.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Tesis doctoral (DoctoralThesis)

Experimental and numerical research on innovative air-cooling systems based on very high efficiency indirect evaporative cooling equipment, Estudio experimental y numérico de sistemas innovadores de enfriamiento de aire basados en equipos de enfriamiento evaporativo indirecto de muy alta eficiencia

  • Romero-Lara, María Jesús
Traditional heating, ventilation and air-conditioning, HVAC, systems lead to increased energy consumption for cooling buildings. Given the progressive increase in outdoor temperatures around the world, resilient air-cooling systems are required to satisfy the growing demand for cooling energy, as well as the needs for thermal comfort and indoor air quality with low energy consumption. Conventional air-cooling systems based on direct expansion units are widely used in buildings such as schools. However, these traditional systems exhibit significant limitations in terms of dehumidification capacity and energy efficiency. For these traditional air-cooling systems the improvement of indoor air quality, hence a higher ventilation rate, results in a significant increase in energy consumption, so they are designed to operate at high recirculation rates in many cases, strictly adhering to regulatory requirements. Efficient air-cooling systems based on dew-point indirect evaporative cooling technology could be a potential alternative to conventional air-cooling systems, due to their higher energy efficiency values under higher outdoor air temperatures. The main objective of the present thesis was to evaluate experimentally and numerically the energy performance of a dew-point indirect evaporative cooler, and a novel renewable air-cooling unit based on a desiccant wheel and a dew-point indirect evaporative cooler, in terms of energy performance and environmental impact. Firstly, a conventional air-cooling system based on a direct expansion unit was compared numerically with the dew-point indirect evaporative cooler and the renewable air-cooling unit in terms of thermal comfort, indoor air quality, energy consumption and CO2 emissions. Several energy simulations were carried out for a standard classroom in the Mediterranean area. More suitable values of thermal comfort and indoor air quality with low energy consumption were obtained for the innovative air-cooling systems. On the other hand, the empirical model of the dewpoint indirect evaporative cooler was adjusted according to several experimental tests. In addition, a new calculation method of seasonal energy efficiency ratio for dew-point indirect evaporative coolers was developed. A very low percentage of relative error with respect to the traditional calculation method was obtained. Finally, the novel renewable air-cooling unit based on a desiccant wheel and the dew-point indirect evaporative cooler was experimentally analysed in terms of sensible cooling capacity, latent capacity and coefficient of performance. The control system of the renewable air-cooling unit was designed to independently control the air temperature, air humidity and indoor CO2 level. The empirical model of the renewable air-cooling unit was also adjusted according to an extensive number of laboratory experimental tests. Several annual energy simulations were also performed with this empirical model and different weather conditions to obtain the feasibility of this novel air-cooling unit. The energy performance of both the dew-point indirect evaporative cooler and the renewable air-cooling unit were studied for different climate zones and under the climate change scenario. The dewpoint indirect evaporative cooler demonstrated high feasibility in hot-dry climates, whereas the novel renewable air-cooling unit proved highly viable in hot-humid climates, primarily due to the functioning of the desiccant wheel. The innovative air-cooling systems based on the dew-point indirect evaporative cooling technology achieved higher energy performance values than conventional air-cooling systems. Furthermore, the renewable air-cooling unit allows independent control of air temperature, humidity and ventilation needs.Therefore, the results of this thesis suggest that the proposed two efficiency aircooling systems could be potential alternatives to conventional air-cooling systems for use in buildings in terms of thermal comfort, indoor air quality, energy efficiency and sustainable environment. The two proposed efficient air-cooling systems should be considered for cooling buildings in the global climate change scenario., Los sistemas tradicionales de calefacción, ventilación y aire acondicionado, HVAC, conllevan un mayor consumo de energía para enfriar los edificios. Dado el progresivo aumento de las temperaturas exteriores en todo el mundo, se necesitan sistemas de enfriamiento por aire resilientes para satisfacer la creciente demanda de energía de refrigeración, así como las necesidades de confort térmico y calidad del aire interior con un bajo consumo energético. Los sistemas convencionales de enfriamiento por aire basados en unidades de expansión directa se utilizan ampliamente en edificios como los colegios. Sin embargo, estos sistemas tradicionales presentan importantes limitaciones en cuanto a capacidad de deshumidificación y eficiencia energética. Para estos sistemas tradicionales de enfriamiento por aire, la mejora de la calidad del aire interior, y por tanto una mayor tasa de ventilación, se traduce en un aumento significativo del consumo de energía, por lo que en muchos casos están diseñados para funcionar con altas tasas de recirculación, cumpliendo estrictamente los requisitos normativos. Los sistemas eficientes de enfriamiento por aire basados en la tecnología de enfriamiento evaporativo indirecto de punto de rocío podrían ser una alternativa potencial a los sistemas convencionales de enfriamiento por aire, debido a sus mayores valores de eficiencia energética bajo temperaturas más elevadas del aire exterior. El objetivo principal de la presente tesis fue evaluar experimental y numéricamente el rendimiento energético de un enfriador evaporativo indirecto de punto de rocío, y de una novedosa unidad de enfriamiento de aire renovable basada en una rueda desecante y un enfriador evaporativo indirecto de punto de rocío, en términos de rendimiento energético e impacto ambiental. En primer lugar, se comparó numéricamente un sistema convencional de enfriamiento por aire basado en una unidad de expansión directa con el enfriador evaporativo indirecto de punto de rocío y la unidad de enfriamiento por aire renovable en términos de confort térmico, calidad del aire interior, consumo energético y emisiones de CO2. Se realizaron varias simulaciones energéticas para un aula estándar de la zona mediterránea. Se obtuvieron valores más adecuados de confort térmico y calidad del aire interior con un bajo consumo energético para los sistemas innovadores de enfriamiento por aire. Por otro lado, se ajustó el modelo experimental del enfriador evaporativo indirecto de punto de rocío de acuerdo con varias pruebas experimentales y se desarrolló un nuevo método de cálculo del ratio de eficiencia energética estacional para enfriadores evaporativos indirectos de punto de rocío. Se obtuvo un porcentaje de error relativo muy bajo con respecto al método de cálculo tradicional. Por último, se analizó experimentalmente la nueva unidad de enfriamiento por aire renovable basada en una rueda desecante y el enfriador evaporativo indirecto de punto de rocío, en términos de capacidad de enfriamiento sensible, capacidad latente y coeficiente de rendimiento. El sistema de control de la unidad de enfriamiento por aire renovable se diseñó para controlar de forma independiente la temperatura del aire, la humedad del aire y el nivel de CO2 interior. El modelo empírico de la unidad de refrigeración por aire renovable también se ajustó de acuerdo con un amplio número de pruebas experimentales de laboratorio. También se realizaron varias simulaciones energéticas anuales con este modelo empírico y diferentes condiciones climáticas para obtener la viabilidad de esta novedosa unidad de refrigeración por aire. Se estudió el rendimiento energético tanto del enfriador evaporativo indirecto de punto de rocío como de la unidad de enfriamiento por aire renovable para diferentes zonas climáticas y bajo el escenario de cambio climático. El enfriador evaporativo indirecto de punto de rocío demostró una gran viabilidad en climas cálidos y secos, mientras que la novedosa unidad de refrigeración por aire renovable resultó muy viable en climas cálidos y húmedos, debido principalmente al funcionamiento de la rueda desecante. Los innovadores sistemas de enfriamiento por aire basados en la tecnología de enfriamiento evaporativo indirecto de punto de rocío alcanzaron valores de rendimiento energético superiores a los de los sistemas de enfriamiento por aire convencionales. Además, la unidad de enfriamiento por aire renovable permite un control independiente de la temperatura del aire, la humedad y las necesidades de ventilación. Por lo tanto, los resultados de esta tesis sugieren que los dos sistemas de enfriamiento por aire eficientes propuestos podrían ser alternativas potenciales a los sistemas de enfriamiento por aire convencionales para su uso en edificios en términos de confort térmico, calidad del aire interior, eficiencia energética y medio ambiente sostenible. Ambos sistemas eficientes de enfriamiento por aire deberían tenerse en cuenta para la refrigeración de edificios en el escenario del cambio climático global.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Enhanced evaporative cooling using additively manufactured PLA–wood composite lattices

  • Conrat, Paula
  • Comino Montilla, Francisco
  • Caruana, Roberta
  • Guilizzoni, Manfredo
  • Romero, Pablo E.
  • Ruiz de Adana, Manuel
Evaporative cooling technologies are increasingly recognized as energy-efficient and sustainable alternatives to conventional air-conditioning systems. In this study, five evaporative cooling pads, four with lattice geometries and one conventional grid-type reference pad, were designed and fabricated through additive manufacturing using a polilactic acid (PLA)-wood composite, then characterized and experimentally evaluated under controlled inlet air conditions. Material characterization revealed a rough mesoporous morphology and intermediate wettability, favouring capillary-driven water retention. Among the tested designs, the octagonal lattice geometry exhibited the largest air–water contact surface, achieving the greatest temperature drop (19.7 °C) and wet bulb effectiveness (0.93), thereby demonstrating superior performance. This geometry was subsequently scaled up into a full-scale prototype incorporating an integrated water distribution system. Statistical analysis confirmed that both inlet air temperature and airflow rate had a significant effect on cooling performance, with coefficients of determination above 0.98. The energy analysis of the prototype showed that the cooling capacity increased up to 800 W, while the energy efficiency ratio ranged between 7 and 87 depending on operating conditions. The findings emphasize the strong connection between material properties, lattice geometry, and energy performance, supporting this design to optimize sustainable evaporative cooling systems for building applications.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Experimental energy and water performance of a renewable air-cooling unit under summer and heatwave conditions in Southern Europe

  • Romero-Lara, María Jesús
  • Ruiz de Adana, Manuel
Conventional air-cooling systems accounting for nearly 50% of the electricity consumption of buildings. Space cooling demand is rapidly increasing in warm regions, where this type of systems suffer from efficiency degradation under extreme outdoor conditions. In addition, long-term experimental evidence on the real performance of hybrid air-cooling technologies during heat extreme events remains scarce. The main objective of this work is to experimentally investigate the energy performance and water consumption of a renewable air-cooling unit based on desiccant cooling (“renewable” denotes the system’s design intent and potential, rather than the energy source applied in the present work). This system, comprising a desiccant wheel and a dew-point indirect evaporative cooler, enables independent control of supply air temperature, humidity, and carbon dioxide levels through adjustable operating modes. Daily tests are conducted over 11 weeks in summer 2022 in Cordoba, Spain (Southern Europe), providing long-term data covering 30 representative heat extreme days. Instantaneous system behaviour is evaluated focusing on supply air and energy balances, while seasonal performance is assessed through daily coefficients for thermal and electrical energy performance and water consumption. The highest sensible and latent cooling energies achieved are 87.3 kWh/day and 37.4 kWh/day, respectively, under severe outdoor conditions. Total daily coefficient of performance reaches up to 15.6 due to high cooling capacity and low electrical consumption, while daily water efficiency reaches 0.55 kWh of cooling per litre. These results provide a reference for the feasibility of hybrid air-cooling systems under real-world heat events and climate change scenarios.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Experimental and numerical analysis of the thermal behaviour of a single-phase immersion-cooled data centre

  • Taddeo, Paolo
  • Romaní Picas, Joaquim
  • Summers, Jon
  • Martorell, Ingrid
  • Salom, Jaume
Server power densities are foreseen to increase, and conventional air-cooling systems will struggle to cope with thermal demand. Single-phase immersion systems are a promising alternative to operate very intensive workload such as high-performance computing, cryptocurrencies mining or research activities. However, few companies deal with this kind of system and there is a lack of energy models that can reproduce an accurate analysis of the system behaviour. This study addresses the experimentation, data collection, and model validation of a singlephase immersion cooling system where 54 open compute project servers, each with a peak power of 400 Watts that are submerged and operated in a dielectric coolant. Results show the evolution of the thermal profile of the system under static and dynamic workloads, and it provides a correlation of server energy use under various system temperatures. The energy model is presented, validated against real data, and exploited to investigate the system response to different cooling conditions. In conclusion, the study demonstrates the validation of the energy model and supports the basis for further investigation., This work has received funding from the European Union H2020 Framework Programme under Grant Agreement no. 857801 (WEDISTRICT). IREC authors would like to thank Generalitat de Catalunya for the project grant given to their research group (2021 SGR 01403). Ingrid Martorell would like to thank Generalitat de Catalunya for the project grant given to her research group (2021 SGR 01370).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Experimental and numerical analysis of the thermal behaviour of a single-phase immersion-cooled data centre

  • Taddeo, Paolo
  • Romaní Picas, Joaquim
  • Summers, Jon
  • Martorell, Ingrid
  • Salom, Jaume
Server power densities are foreseen to increase, and conventional air-cooling systems will struggle to cope with thermal demand. Single-phase immersion systems are a promising alternative to operate very intensive workload such as high-performance computing, cryptocurrencies mining or research activities. However, few companies deal with this kind of system and there is a lack of energy models that can reproduce an accurate analysis of the system behaviour. This study addresses the experimentation, data collection, and model validation of a singlephase immersion cooling system where 54 open compute project servers, each with a peak power of 400 Watts that are submerged and operated in a dielectric coolant. Results show the evolution of the thermal profile of the system under static and dynamic workloads, and it provides a correlation of server energy use under various system temperatures. The energy model is presented, validated against real data, and exploited to investigate the system response to different cooling conditions. In conclusion, the study demonstrates the validation of the energy model and supports the basis for further investigation., This work has received funding from the European Union H2020 Framework Programme under Grant Agreement no. 857801 (WEDISTRICT). IREC authors would like to thank Generalitat de Catalunya for the project grant given to their research group (2021 SGR 01403). Ingrid Martorell would like to thank Generalitat de Catalunya for the project grant given to her research group (2021 SGR 01370).
Docta Complutense
Publicación Capítulo o parte de un libro (BookPart)

Social Life Cycle Analysis: An Overview of the Literature to Compare and Complement Current Methodologies

  • Hidalgo-Carvajal, David
  • De Stefano, María Cristina
  • Fernández Aguirre, Rodrigo
Even more studies on life cycle analysis highlight the environmental, economic, and social impact of supply chains, making evident to society realities that were unknown so far. Most academic and professional works are focused on developing indicators and standards to measure the environmental and economic impact of goods and services, whereas there are low contributions that improve tools to capture their social effects. The main difficulty in developing and applying social life cycle analysis (S-LCA) is due to the presence of high components of subjectivity and context specificity. The objective of this study is to offer a systematic literature review on S-LCA to understand in depth the existing applied methodologies. From the review, this paper identifies some aspects that the current methodologies are not considering and proposes as a result to complement such methodologies with other relevant perspectives.
Archivo Digital UPM
Publicación Artículo científico (JournalArticle)

Comprehensive analysis of hot water tank sizing for a hybrid solar-biomass district heating and cooling

  • Roncal Casano, Juan José|||0000-0003-1835-1303
  • Rodríguez Martín, Javier|||0000-0003-1451-0856
  • Abánades Velasco, Alberto|||0000-0003-0179-5987
  • Muñoz Antón, Javier|||0000-0002-1980-0863
  • Gurruchaga, Ignasi
  • González Castellví, Daniell
Archivo Digital UPM
Publicación Artículo científico (JournalArticle)

Proposal of a thermocline molten salt storage tank for district heating and cooling

  • Abánades Velasco, Alberto|||0000-0003-0179-5987
  • Rodríguez Martín, Javier|||0000-0003-1451-0856
  • Roncal Casano, Juan José|||0000-0003-1835-1303
  • Caraballo, Adrián
  • Galindo, Francisca
Archivo Digital UPM
Publicación Artículo científico (JournalArticle)

Recycled PLA for 3D Printing: A Comparison of Recycled PLA Filaments from Waste of Different Origins after Repeated Cycles of Extrusion

  • Hidalgo Carvajal, David|||0000-0001-7771-0906
  • Hortal Muñoz, Álvaro
  • Garrido González, José J.|||0000-0001-7696-7902
  • Carrasco Gallego, Ruth|||0000-0002-9542-3836
  • Alcázar Montero, María Victoria|||0000-0002-1891-3209
Archivo Digital UPM
Publicación Tesis doctoral (DoctoralThesis)

Modular Simulation Methodology for the Economical and Environmental Optimization of District Heating/Cooling Systems to Achieve Net Zero

Archivo Digital UPM
Publicación Tesis doctoral (DoctoralThesis)

A Circular Economy Living Lab –Supporting the transition of a university campus towards a circular and regenerative system

Archivo Digital UPM
Publicación Artículo científico (JournalArticle)

Environmental and Social Life Cycle Assessment of Data Centre Heat Recovery Technologies Combined with Fuel Cells for Energy Generation

  • Puentes Bejarano, Camila Andrea
  • Pérez Rodríguez, Javier|||0000-0002-3896-621X
  • Andrés Almeida, Juan Manuel de|||0000-0002-0654-5496
  • Hidalgo Carvajal, David|||0000-0001-7771-0906
  • Gustaffsson, Jonas|||0000-0002-9759-5594
  • Summers, Jon|||0000-0001-8266-5038
  • Abánades Velasco, Alberto|||0000-0003-0179-5987
Archivo Digital UPM
Publicación Artículo científico (JournalArticle)

Environmental and Social Impacts of Renewable Energy-Driven Centralized Heating/Cooling Systems: A Comparison with Conventional Fossil Fuel-Based Systems

  • Pérez Rodríguez, Javier|||0000-0002-3896-621X
  • Hidalgo Carvajal, David|||0000-0001-7771-0906
  • Andrés Almeida, Juan Manuel de|||0000-0002-0654-5496
  • Abánades Velasco, Alberto|||0000-0003-0179-5987