MODELADO CINEMATICO Y DINAMICO DEL MOVIMIENTO DE LOS TEJIDOS BLANDOS. APLICACION AL DISEÑO DE MODELOS BIOMECANICOS (DESARROLLO DE TECNICAS EXPERIMENTALES Y VALIDACION DE MODELOS)

DPI2009-13830-C02-02

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2009
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario INSTITUTO DE BIOMECANICA DE VALENCIA
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Model of Soft Tissue Artifact Propagation to Joint Angles in Human Movement Analysis

  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Besa Gonzálvez, Antonio José|||0000-0002-7084-9937
  • De Rosario Martínez, Helios
[EN] This work describes the kinematic laws that govern the transmission of soft tissue artifact errors to kinematic variables in the analysis of human movements. Artifacts are described as relative translations and rotations of the marker cluster over the bone, and a set of explicit expressions is defined to account for the effect of that relative motion on different representations of rotations: the rotation around the screw axis, or rotation vector, and three Euler angle sequences (XY0Z, YX0Y00, ZX0 Y00). Although the error transmission is nonlinear in all cases, the effect of artifacts is greater on Euler sequences than on the rotation vector. Specifically, there are crosstalk effects in Euler sequences that amplify the errors near singular configurations. This fact is an additional source of variability in studies that describe artifacts by comparing the Euler angles obtained from skin markers, with the angles of an artifact-free gold standard. The transmission of errors to rotation vector coordinates is less variable or dependent on the type of motion. This model has been tested in an experiment with a deformable mechanical model with a spherical joint., This work has been funded by the Spanish Government and co-financed by EU FEDER funds (Grants DPI2009-13830-C02-01 and DPI2009-13830-C02-02).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Kinematic description of soft tissue artifacts: quantifying rigid versus deformation components and their relation with bone motion

  • De Rosario Martínez, Helios
  • Conejero Navarro, Efrain
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Besa Gonzálvez, Antonio José|||0000-0002-7084-9937
  • Mata Amela, Vicente|||0000-0003-2255-0567
[EN] This paper proposes a kinematic approach for describing soft tissue artifacts (STA) in human movement analysis. Artifacts are represented as the field of relative displacements of markers with respect to the bone. This field has two components: deformation component (symmetric field) and rigid motion (skew-symmetric field). Only the skew-symmetric component propagates as an error to the joint variables, whereas the deformation component is filtered in the kinematic analysis process. Finally, a simple technique is proposed for analyzing the sources of variability to determine which part of the artifact may be modeled as an effect of the motion, and which part is due to other sources. This method has been applied to the analysis of the shank movement induced by vertical vibration in 10 subjects. The results show that the cluster deformation is very small with respect to the rigid component. Moreover, both components show a strong relationship with the movement of the tibia. These results suggest that artifacts can be modeled effectively as a systematic relative rigid movement of the marker cluster with respect to the underlying bone. This may be useful for assessing the potential effectiveness of the usual strategies for compensating for STA. © 2012 International Federation for Medical and Biological Engineering., This work has been funded by the Spanish Government and co-financed by EU FEDER funds (Grants DPI2009-13830-C02-01, DPI2009-13830-C02-02 and IMPIVA IMDEEA/2012/79 and IMDEEA/2012/80).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Propagation of Artifact Errors on Kinematic Variables. Effect on Euler Angles

  • De Rosario Martínez, Helios
  • Moreno Cano, Rafael
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Besa Gonzálvez, Antonio José|||0000-0002-7084-9937
This work has been funded by the Spanish Government and co-financed by EU FEDER funds (Grants DPI2009-13830-C02-01, DPI2009-13830- C02-02 and IMPIVA IMIDIC/2010/84)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Representation of planar motion of complex joints by means of rolling pairs. Application to neck motion

  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • De Rosario Martínez, Helios
  • Galvez Griso, Jose Antonio
[EN] We propose to model planar movements between two human segments by means of rolling-without-slipping kinematic pairs. We compute the path traced by the instantaneous center of rotation (ICR) as seen from the proximal and distal segments, thus obtaining the fixed and moving centrodes, respectively. The joint motion is then represented by the rolling-without-slipping of one centrode on the other. The resulting joint kinematic model is based on the real movement and accounts for nonfixed axes of rotation; therefore it could improve current models based on revolute pairs in those cases where joint movement implies displacement of the ICR. Previous authors have used the ICR to characterize human joint motion, but they only considered the fixed centrode. Such an approach is not adequate for reproducing motion because the fixed centrode by itself does not convey information about body position. The combination of the fixed and moving centrodes gathers the kinematic information needed to reproduce the position and velocities of moving bodies. To illustrate our method, we applied it to the flexion-extension movement of the head relative to the thorax. The model provides a good estimation of motion both for position variables (mean R pos=0.995) and for velocities (mean R vel=0.958). This approach is more realistic than other models of neck motion based on revolute pairs, such as the dual-pivot model. The geometry of the centrodes can provide some information about the nature of the movement. For instance, the ascending and descending curves of the fixed centrode suggest a sequential movement of the cervical vertebrae. © 2010 Elsevier Ltd., This work was funded by the Spanish Government and co-financed by EU FEDER funds (Grants DPI2006-14722-C02-01, DPI2006-14722-C02-02, DPI2009-13830-C02-01, DPI2009-13830-C02-02 and Ramon y Cajal contract to JAG).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Propagation of soft tissue artifacts to the center of rotation: A model for the correction of functional calibration techniques

  • De Rosario Martínez, Helios
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Besa Gonzálvez, Antonio José|||0000-0002-7084-9937
  • Valera Fernández, Ángel|||0000-0001-6843-6394
This paper presents a mathematical model for the propagation of errors in body segment kinematics to the location of the center of rotation. Three functional calibration techniques, usually employed for the gleno-humeral joint, are studied: the methods based on the pivot of the instantaneous helical axis (PIHA) or the finite helical axis (PFHA), and the ¿symmetrical center of rotation estimation¿ (SCoRE). A procedure for correcting the effect of soft tissue artifacts is also proposed, based on the equations of those techniques and a model of the artifact, like the one that can be obtained by double calibration. An experiment with a mechanical analog was performed to validate the procedure and compare the performance of each technique. The raw error (between 57 and 68 mm) was reduced by a proportion of between 1:6 and less than 1:15, depending on the artifact model and the mathematical method. The best corrections were obtained by the SCoRE method. Some recommendations about the experimental setup for functional calibration techniques and the choice of a mathematical method are derived from theoretical considerations about the formulas and the results of the experiment., This work has been funded by the Spanish Government (Grants DPI2009-13830-C02-01, DPI2009-13830-C02-02, DPI2010-20814-C02-01, and DPI2010-20814-C02-02).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Point of optimal kinematic error: Improvement of the instantaneous helical pivot method for locating centers of rotation

  • De Rosario Martínez, Helios
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Mata Amela, Vicente|||0000-0003-2255-0567
[EN] This paper proposes a variation of the instantaneous helical pivot technique for locating centers of rotation. The point of optimal kinematic error (POKE), which minimizes the velocity at the center of rotation, may be obtained by just adding a weighting factor equal to the square of angular velocity in Woltring's equation of the pivot of instantaneous helical axes (PIHA). Calculations are simplified with respect to the original method, since it is not necessary to make explicit calculations of the helical axis, and the effect of accidental errors is reduced. The improved performance of this method was validated by simulations based on a functional calibration task for the gleno-humeral joint center. Noisy data caused a systematic dislocation of the calculated center of rotation towards the center of the arm marker cluster. This error in PIHA could even exceed the effect of soft tissue artifacts associated to small and medium deformations, but it was successfully reduced by the POKE estimation., This work has been funded by the Spanish Government (Grants DPI2009-13830-C02-01, DPI2009-13830-CO2-02, DPI2010-20814-CO2-01, DPI2010-20814-CO2-02).