Pasar al contenido principal

DETECTORES DE "VERTEXING" Y "TRACKING" AVANZADOS PARA LOS FUTUROS EXPERIMENTOS COLISIONADORES

FPA2015-71292-C2-2-P

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D (Excelencia / Generación de Conocimiento)
Año convocatoria 2015
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario UNIVERSIDAD DE BARCELONA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Results on proton-irradiated 3D pixel sensors interconnected to RD53A readout ASIC

  • Duarte Campderros, J.
  • Currás, Esteban
  • Fernández-García, Marcos
  • Gómez, Gervasio
  • García, A.
  • González, Javier
  • Silva Jimenez, E.
  • Vila, Iván
  • Jaramillo, R.
  • Meschini. M.
  • Dinardo, M. E.
  • Gennai, S.
  • Moroni, L.
  • Demaria, N.
  • Monteil, E.
  • Messineo, A.
  • Hidalgo, Salvador
  • Merlos Domingo, Ángel
  • Pellegrini, Giulio
  • Quirion, David
  • Manna, M.
On behalf of the CMS Collaboration: et al., Test beam results obtained with 3D pixel sensors bump-bonded to the RD53A prototype readout ASIC are reported. Sensors from FBK Italy and IMB-CNM (Spain) have been tested before and after proton-irradiation to an equivalent fluence of about 1 × 10 ≠cm (1MeV equivalent neutrons). This is the first time that one single collecting electrode fine pitch 3D sensors are irradiated up to such fluence bump-bonded to a fine pitch ASIC. The preliminary analysis of the collected data shows no degradation on the hit detection efficiencies of the tested sensors after high energy proton irradiation, demonstrating the excellent radiation tolerance of the 3D pixel sensors. Thus, they will be excellent candidates for the extreme radiation environment at the innermost layers of the HL-LHC experiments., This project has been partially supported by the Spanish Ministry of Science, Innovation and Universities under grants FPA2015-71292-C2-2-P, FPA2017-85155-C4-1-R and FPA2017-85155-C4-2-R; and the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement no. 654168 (AIDA-2020).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

High resolution 3D characterization of silicon detectors using a Two Photon Absorption Transient Current Technique

  • Fernández-García, Marcos
  • Jaramillo, R.
  • Moll, Michael
  • Montero Santos, Raúl
  • Palomo, Francisco Rogelio
  • Vila, Iván
  • Wiehe, Moritz
The Two Photon Absorption Transient Current Technique (TPA-TCT) is a tool to characterize semiconductor detectors using a spatially confined laser probe. Excess charge carriers are produced by the simultaneous absorption of two sub-bandgap photons in the material. The current induced by the motion of carriers is studied using well known TCT systems. Differently to standard TCT where the energy deposition (pair creation) is continuous along the beam, TPA-TCT reduces this region to an ellipsoidal volume, achieving thus, true 3D spatial resolution. This paper gives an overview of the technique and shows its performance in irradiated detectors, in particular diodes and High Voltage CMOS detectors., This work was performed in the framework of the CERN-RD50 collaboration under the projects 2016-04, 2017-02. Activity partially supported by the Spanish Ministry of Science grants FPA2015-71292-C2-2-P and FPA2017-85155-C4-1-R; and the European Union’s Horizon 2020 Research and Innovation program under Grant Agreement no. 654168 (AIDA-2020)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Inverse Low Gain Avalanche Detectors (iLGADs) for precise tracking and timing applications

  • Currás, Esteban
  • Carulla, M.
  • Centis Vignali, Matteo
  • Duarte Campderros, J.
  • Fernández-García, Marcos
  • Flores, David
  • García Alonso, A.
  • Gómez, Gervasio
  • González, Javier
  • Hidalgo, Salvador
  • Jaramillo, R.
  • Merlos Domingo, Ángel
  • Moll, Michael
  • Pellegrini, Giulio
  • Quirion, David
  • Vila, Iván
arXiv:1904.02061v1, Low Gain Avalanche Detector (LGAD) is the baseline sensing technology of the recently proposed Minimum Ionizing Particle (MIP) end-cap timing detectors (MTD) at the Atlas and CMS experiments. The current MTD sensor is designed as a multi-pad matrix detector delivering a poor position resolution, due to the relatively large pad area, around 1 mm2; and a good timing resolution, around 20–30 ps. Besides, in his current technological incarnation, the timing resolution of the MTD LGAD sensors is severely degraded once the MIP particle hits the inter-pad region since the signal amplification is missing for this region. This limitation is named as the LGAD fill-factor problem. To overcome the fill factor problem and the poor position resolution of the MTD LGAD sensors, a p-in-p LGAD (iLGAD) was introduced. Contrary to the conventional LGAD, the iLGAD has a non-segmented deep p-well (the multiplication layer). Therefore, iLGADs should ideally present a constant gain value over all the sensitive region of the device without gain drops between the signal collecting electrodes; in other words, iLGADs should have a 100% fill-factor by design. In this paper, tracking and timing performance of the first iLGAD prototypes is presented., RD50 Collaboration for its support. This activity was partially supported by the Spanish Ministry of Science under grants FPA2015-71292-C2-2-P, FPA2017-85155-C4-1-R and FPA2017-85155-C4-2-R; and the European Union Horizon 2020 Research and Innovation Framework Programme under Grant Agreement no. 654168 (AIDA-2020)., Peer reviewed