Pasar al contenido principal

DISEÑO DE SISTEMAS DE ALMACENAMIENTO OPTIMOS BASADOS EN BATERIAS LI-ION NUEVAS Y DE SEGUNDA VIDA PARA INTEGRACION DE ENERGIAS RENOVABLES

PID2019-111262RB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD PUBLICA DE NAVARRA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Health indicator selection for state of health estimation of second-life lithium-ion batteries under extended ageing

  • Braco Sola, Elisa
  • San Martín Biurrun, Idoia
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
  • Stroe, Daniel-Ioan
Nowadays, the economic viability of second-life (SL) Li-ion batteries from electric vehicles is still uncertain. Degradation assessment optimization is key to reduce costs in SL market not only at the repurposing stage, but also during SL lifetime. As an indicator of the ageing condition of the batteries, state of health (SOH) is currently a major research topic, and its estimation has emerged as an alternative to traditional characterization tests. In an initial stage, all SOH estimation methods require the extraction of health indicators (HIs), which influence algorithm complexity and on-board implementation. Nevertheless, a literature gap has been identified in the assessment of HIs for reused Li-ion batteries. This contribution targets this issue by analysing 58 HIs obtained from incremental capacity analysis, partial charging, constant current and constant voltage stage, and internal resistance. Six Nissan Leaf SL modules were aged under extended cycling testing, covering a SOH range from 71.2 % to 24.4 %. Results show that the best HI at the repurposing stage was obtained through incremental capacity analysis, with 0.2 % of RMSE. During all SL use, partial charge is found to be the best method, with less than 2.0 % of RMSE. SOH is also estimated using the best HI and different algorithms. Linear regression is found to overcome more complex options with similar estimation accuracy and significantly lower computation times. Hence, the importance of analysing and selecting a good SL HI is highlighted, given that this made it possible to obtain accurate SOH estimation results with a simple algorithm., This work is part of the projects PID2019-111262RB-I00, funded by MCIN/AEI/10.13039/501100011033/, STARDUST (774094), funded by European Union's Horizon 2020 research and innovation programme, HYBPLANT (0011-1411-2022-000039), funded by Government of Navarre, and a Ph.D. scholarship, also funded by Government of Navarre. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Energy management for an electro-thermal renewable based residential microgrid with energy balance forecasting and demand side management

  • Pascual Miqueleiz, Julio María
  • Arcos Avilés, Diego
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
  • Marroyo Palomo, Luis
This paper proposes an energy management strategy for a residential microgrid comprising photovoltaic (PV) panels, a small wind turbine and solar thermal collectors. The microgrid can control the power exchanged with the grid thanks to a battery and a controllable electric water heater, which provide two degrees of freedom to the control strategy. As input data, the proposed control strategy uses the battery state of charge (SOC), the temperature of the hot water tank, the power of each microgrid element as well as the demand and renewable generation forecasts. By using forecasted data and by controlling the electric water heater, the strategy is able to achieve a better grid power profile while using a smaller battery than previous works, hence reducing the overall cost of the system. The strategy is tested by means of simulation with real data for one year and it is also experimentally validated in the microgrid built at the Renewable Energy Laboratory at the UPNA., The authors would like to acknowledge that this work has been partially funded under grants PID2019-110816RB-C21 and PID2019–111262RB–I00 by the Spanish State Research Agency (AEI/ 10.13039/501100011033). And also by VLIR-UOS and the Belgian Development Cooperation (DGD) under the project EC2020SIN322A101 (2020-EXT-007).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

A PV ramp-rate control strategy to extend battery lifespan using forecasting

  • González Moreno, Alejandro
  • Marcos Álvarez, Javier
  • Parra Laita, Íñigo de la
  • Marroyo Palomo, Luis
This study analyses and presents a new ramp-rate control algorithm for smoothing PV power fluctuations, designed to address three fundamental objectives: to reduce battery cycling, to meet minimum storage requirements and to be able to operate, without ramp-rate violations, with real publicly-available forecasting. The algorithm was compared to three benchmark methods and, as a performance limit, also to a hypothetical perfect prediction. Different performance variables were analyzed for all the strategies within a restricted ramp-rate constraint (2%/min): minimum storage requirement, battery power distributions, throughput energy, state of charge (SOC) distributions, degradation (calendar and cycling), expected battery lifespan and levelized cost of energy (LCOE). The proposal proves to be the most cost-effective smoothing technique and the simulation results show that its performance is comparable to the obtained with the use of an assumed perfect prediction., Support of the Spanish State Research Agency (AEI) under grants PID2019111262RB-I00 and PID2019-110816RB-C21. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Impact of micro-cycles on the lifetime of lithium-ion batteries: an experimental study

  • Soto Cabria, Adrián
  • Berrueta Irigoyen, Alberto
  • Mateos Inza, Miren
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
Experimental aging studies are commonly conducted on lithium-ion batteries by full charge and discharge cycles. However, such profiles may differ from the actual operation of batteries in electric vehicles and stationary applications, where they are subjected to different partial charges and discharges. These partial cycles, which take place during a main charge or discharge process, are called micro-cycles if their depth of discharge is <2 %. A number of authors have pointed out the relevance of the time resolution to estimate the energy throughput of a battery due to these micro-cycles in applications such as renewable microgrids. However, to the best of our knowledge, there are no experimental studies in the literature that assess the impact of these micro-cycles on battery degradation. In this article, the impact of micro-cycles on the loss of performance of a lithium-ion battery is experimentally studied. The results show that micro-cycles have a negligible, or even positive effect on the aging of lithium-ion cells compared to the aging caused by full cycles. In fact, if charge throughput or equivalent full cycles are used to measure the use of a battery, then cells subjected to micro-cycles exhibit a 50 % extended lifetime compared to cells only subjected to full cycles. More precisely, cells including micro-cycles with depth of discharge of 0.5 % lasted for nearly 3000 equivalent full cycles, whereas cells aged under standard deep cycles lasted for no >1500. Nevertheless, if the number of deep cycles, disregarding micro-cycles, is the unit to measure battery use, then the degradation of cells with and without micro-cycles is similar. Based on this result, the number of cycles can be identified as a more accurate variable to measure the use of a cell, in comparison to charge throughput., This work is part of the projects PID2019-111262RB-I00, funded by MCIN/AEI/10.13039/501100011033/, STARDUST (774094), funded by European Union¿s Horizon 2020 research and innovation programme, HYBPLANT (0011-1411-2022-000039), funded by Government of Navarre, and a Ph.D. scholarship, funded by Public University of Navarre. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

An energy management system design using fuzzy logic control: smoothing the grid power profile of a residential electro-thermal microgrid

  • Arcos Avilés, Diego
  • Pascual Miqueleiz, Julio María
  • Guinjoan Gispert, Francesc
  • Marroyo Palomo, Luis
  • García Gutiérrez, Gabriel
  • Gordillo, Rodolfo
  • Llanos, Jacqueline
  • Sanchis Gúrpide, Pablo
  • Motoasca, Emilia
This work deals with the design of a Fuzzy Logic Control (FLC) based Energy Management System (EMS) for smoothing the grid power prole of a grid-connected electro-thermal microgrid. The case study aims to design an Energy Management System (EMS) to reduce the impact on the grid power when renewable energy sources are incorporated to pre-existing grid-connected household appliances. The scenario considers a residential microgrid comprising photovoltaic and wind generators, at-plate collectors, electric and thermal loads and electrical and thermal energy storage systems and assumes that neither renewable generation nor the electrical and thermal load demands are controllable. The EMS is built through two low-complexity FLC blocks of only 25 rules each. The first one is in charge of smoothing the power prfile exchanged with the grid, whereas the second FLC block drives the power of the Electrical Water Heater (EWH). The EMS uses the forecast of the electrical and thermal power balance between generation and consumption to predict the microgrid behavior, for each 15-minute interval, over the next 12 hours. Simulations results, using real one-year measured data show that the proposed EMS design achieves 11.4% reduction of the maximum power absorbed from the grid and an outstanding reduction of the grid power profile ramp-rates when compared with other state-of-the-art studies., This work was supported in part by the projects 2019-PIC-003-CTE and 2020-EXT-007 from the Research Group of Propagation, Electronic Control, and Networking (PROCONET) of Universidad de las Fuerzas Armadas ESPE, in part by the Belgian Development Cooperation (DGD) and the VLIR-UOS under the project EC2020SIN322A101, in part by the Spanish Ministry of Industry and Competitiveness under Grant DPI2017-85404 and Grant PID2019-111443RB-100, and in part by the Spanish State Research Agency (AEI/10.13039/501100011033) under Grant PID2019-110816RB-C21 and Grant PID2019-111262RB-I00.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

In-field energy performance of solar PV module made of UMG silicon

  • Guerra Menjívar, Moisés Roberto
  • Parra Laita, Íñigo de la
  • García Solano, Miguel
  • Pascual Miqueleiz, Julio María
Upgraded metallurgical grade silicon (UMG-Si) PV modules have failed to make their space in the PV market, which was partly to the uncertainty on their in-field performance that brings the wide disparity of results published over the years. The most-recently developed UMG-Si PV modules have demonstrated similar initial degradation and efficiencies under standard test conditions (STC) to those obtained with conventional solar grade silicon (SoG-Si). Nevertheless, their performance under operating conditions other than STC and its impact on the energy production are key aspects that have not yet been properly characterized in the literature. This article analyzes the in-field performance of a PV generator comprised of recently developed UMG-Si modules. This performance was compared to that of another PV generator comprising standard polysilicon modules. The cells and modules of both types of generators were made by the same manufacturer in the same period and on the same production lines, which guarantees that performance differences encountered are exclusively due to the silicon employed. Contrary to the previous experience, this article reveals that UMG-Si modules do not necessarily present a better temperature performance than today's conventional modules. The analyzed UMG-Si modules presented 1.6% less efficiency under low irradiance conditions, but this different irradiance performance led to an insignificant difference (less than 0.5%) in their energy production. No significant degradation was measured in both UMG-Si and SoG-Si modules during the two-year analyzed period, being the final energy performance of both types of modules essentially the same. These results can be considered as highly representative of the current state-of-the-art of UMG-Si technology., This work was supported by the Spanish State Research Agency and the ERDFEU under Grant PID2019-110816RB-C21 and Grant PID2019-111262RB-I00.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Control method to coordinate inverters and batteries for power ramp-rate control in large PV plants: minimizing energy losses and battery charging stress

  • González Moreno, Alejandro
  • Marcos Álvarez, Javier
  • Parra Laita, Íñigo de la
  • Marroyo Palomo, Luis
This work presents a novel control method for multi-megawatt photovoltaic (PV) plants that is able to regulate each plant inverter and the battery system to mitigate PV power fluctuations. The proposed control method makes it possible to implement different PV ramp-rate control strategies based on the use of batteries and the limitation of inverters during positive fluctuations, which have been conceptually proposed in the specialized bibliography, but have omitted how to perform the coordination between PV generators. The dynamic model and the tuning of the control parameters are presented and the method is used to correctly implement different inverter-limitation strategies using 5-second data from a real 45 MWp PV plant. Furthermore, a new control strategy is proposed. This strategy reduces curtailment losses to negligible values and takes into account and addresses the intrinsic asymmetry in the battery charging and discharging capability, an issue that has been overlooked in the specialized bibliography. The results show that the proposed control method can effectively control each of the multiple inverters in order to obtain the desired PV plant operation to regulate the battery charging power, even during highly fluctuating scenarios., The authors to acknowledge the support of the Spanish State Research Agency (AEI) under grants PID2019111262RB-I00 and PID2019-110816RB-C21. Alejandro González-Moreno would like to thank the Universidad Pública de Navarra (UPNA) for its financial support. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Design and on-field validation of an embedded system for monitoring second-life electric vehicle lithium-ion batteries

  • Castillo Martínez, Diego Hilario
  • Rodríguez Rodríguez, Adolfo Josué
  • Soto Cabria, Adrián
  • Berrueta Irigoyen, Alberto
  • Vargas Requena, David Tomás
  • Matías Maestro, Ignacio
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
  • Rodríguez Rodríguez, Wenceslao Eduardo
In the last few years, the growing demand for electric vehicles (EVs) in the transportation sector has contributed to the increased use of electric rechargeable batteries. At present, lithium-ion (Li-ion) batteries are the most commonly used in electric vehicles. Although once their storage capacity has dropped to below 80¿70% it is no longer possible to use these batteries in EVs, it is feasible to use them in second-life applications as stationary energy storage systems. The purpose of this study is to present an embedded system that allows a Nissan® LEAF Li-ion battery to communicate with an Ingecon® Sun Storage 1Play inverter, for control and monitoring purposes. The prototype was developed using an Arduino® microcontroller and a graphical user interface (GUI) on LabVIEW®. The experimental tests have allowed us to determine the feasibility of using Li-ion battery packs (BPs) coming from the automotive sector with an inverter with no need for a prior disassembly and rebuilding process. Furthermore, this research presents a programming and hardware methodology for the development of the embedded systems focused on second-life electric vehicle Li-ion batteries. One second-life battery pack coming from a Nissan® Leaf and aged under real driving conditions was integrated into a residential microgrid serving as an energy storage system (ESS)., This work was supported by: 1. Spanish State Research Agency: PID2019-111262RBI00/AEI/10.13039/501100011033; 2. Government of Navarra under Research Project: 0011-1411-2022-000039 HYBPLANT; 3. European Union's Horizon 2020 Research and Innovation Programme (Stardust-Holistic and Integrated Urban Model for Smart Cities) under Grant 774094.; 4. To the Autonomous University of Tamaulipas (México) for APC support.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Experimental assessment of first- and second-life electric vehicle batteries: performance, capacity dispersion, and aging

  • Braco Sola, Elisa
  • San Martín Biurrun, Idoia
  • Berrueta Irigoyen, Alberto
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
Nowadays, the reuse of electric vehicle batteries is considered to be a feasible alternative to recycling, as it allows them to benefit from their remaining energy capacity and to enlarge their lifetime. Stationary applications, such as self-consumption or off-grid systems support, are examples of second-life (SL) uses for retired batteries. However, reused modules that compose these batteries have heterogeneous properties, which limit their performance. This article aims to assess the influence of degradation in modules from electric vehicles, covering three main aspects: performance, capacity dispersion, and extended SL behavior. First, a complete characterization of new and reused modules is carried out, considering three temperatures and three discharge rates. In the second stage, intra- and intermodule capacity dispersions are evaluated with new and reused samples. Finally, the behavior during SL is also analyzed, through an accelerated cycling test so that the evolution of capacity and dispersion are assessed. Experimental results show that the performance of reused modules is especially undermined at low temperatures and high current rates, as well as in advanced stages of aging. The intramodule dispersion is found to be similar in reused and new samples, while the intermodule differences are nearly four times greater in SL., This work was supported in part by the Spanish State Research Agency (AEI) under Grant PID2019-111262RB-I00/AEI/10.13039/501100011033 and Grant DPI2016-80641-R, in part by the European Union under the H2020 Project STARDUST under Grant 774094, in part by the Government of Navarra under Research Project 0011-1411-2018-000029 GERA, and in part by the Public University of Navarre under Project ReBMS PJUPNA1904.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Influence of control in cycling degradation when batteries perform PV ramp-rate control

  • González Moreno, Alejandro
  • Marcos Álvarez, Javier
  • Parra Laita, Íñigo de la
  • Marroyo Palomo, Luis
This work studies the importance of the correct selection of control parameters in order to avoid unnecessary cycling in batteries when they perform PV smoothing. The classic ramp-rate control method (CRRC) is studied as smoothing technique and the key role of the state of charge (SOC) control is analyzed for a real 38.5 MW PV plant, particularly the influence of proportional gain (K). Depending on K, battery cycling degradation (CyD), power requirements, SOC limits and throughout energy performance were discussed. According to the results, the correct tuning could prolong battery lifespan by reducing cycling degradation up to 80% (depending on the fluctuation restrictions and K) and avoiding unnecessary energy losses, power requirements and undesirable SOC operation levels. Finally, a simple general rule is proposed to set K value when CRRC is used and its applicability is tested by simulating two additional PV plants with rated power of 1.1 and 75.6 MW., This work was supported in part by the Spanish State Research Agency (AEI) under grants PID2019-111262RBI00 and PID2019-110816RB-C21-I00 as well as the Doctoral Scholarships funded by Public University of Navarra (UPNA).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

State of health estimation of second-life lithium-ion batteries under real profile operation

  • Braco Sola, Elisa
  • San Martín Biurrun, Idoia
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
  • Stroe, Daniel-Ioan
The economic viability of second-life (SL) Li-ion batteries from electric vehicles (EVs) is still uncertain nowadays. Assessing the internal state of reused cells is key not only at the repurposing stage but also during their SL operation. As an alternative of the traditional capacity tests used to this end, the estimation of State of Health (SOH) allows to reduce the testing time and the need of equipment, thereby reinforcing the economic success of SL batteries. However, the estimation of SOH in real SL operation has been rarely analysed in literature. This contribution aims thus to cover this gap, by focusing on the experimental assessment of SOH estimation in reused modules from Nissan Leaf EVs under two SL scenarios: a residential household with self-consumption and a fast charge station for EVs. By means of partial charge and experimental data from cycling and calendar ageing tests, accuracy and robustness of health indicators is firstly assessed. Then, SOH estimation is carried out using real profiles, covering a SOH range from 91.3 to 31%. Offline assessment led to RMSE values of 0.6% in the residential profile and 0.8% in the fast charge station, with a reduction in testing times of 85% compared to a full capacity test. In order to avoid the interruption of battery operation, online assessment in profiles was also analysed, obtaining RMSE values below 1.3% and 3.6% in the residential and charging station scenarios, respectively. Therefore, the feasibility of SOH estimation in SL profiles is highlighted, as it allows to get accurate results reducing testing times or even without interrupting normal operation., This work is part of the projects PID2019-111262RB-I00, funded by MCIN/AEI, Spain/ 10.13039/501100011033/, STARDUST (774094), funded by European Union’s Horizon 2020 research and innovation programme, HYBPLANT (0011-1411-2022-000039), funded by Government of Navarre, Spain, and a Ph.D. scholarship, also funded by Government of Navarre. Open access funding provided by Universidad Pública de Navarra, Spain .
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Fast capacity and internal resistance estimation method for second-life batteries from electric vehicles

  • Braco Sola, Elisa
  • San Martín Biurrun, Idoia
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
The success of second-life (SL) Li-ion batteries from electric vehicles is still conditioned by their technical and economic viability. The knowledge of the internal parameters of retired batteries at the repurposing stage is key to ensure their adequate operation and to enlarge SL lifetime. However, traditional characterization methods require long testing times and specific equipment, which result in high costs that may jeopardize the economic viability of SL. In the seek of optimizing the repurposing stage, this contribution proposes a novel fast characterization method that allows to estimate capacity and internal resistance at various state of charge for reused cells, modules and battery packs. Three estimation models are proposed. The first of them is based on measurements of AC resistance, the second on DC resistance and the third combines both resistance types. These models are validated in 506 cells, 203 modules and 3 battery packs from different Nissan Leaf vehicles. The results achieved are satisfactory, with mean absolute percentage errors (MAPE) below 2.5% at cell and module level in capacity prediction and lower than 2.4% in resistance estimation. Considering battery pack level, MAPE is below 4.2% and 1.8% in capacity and resistance estimation respectively. With the proposed method, testing times are reduced from more than one day to 2 min per cell, while energy consumption is lowered from 1.4 kWh to 1 Wh. In short, this study contributes to the reduction of repurposing procedures and costs, and ultimately to the success of SL batteries business model., This work is part of the projects PID2019-111262RB-I00, funded by MCIN/AEI, Spain/10.13039/501100011033/, STARDUST (774094), funded by European Union’s Horizon 2020 research and innovation programme, HYBPLANT, Spain (0011-1411-2022-000039), funded by Government of Navarre, Spain, and a Ph.D. scholarship, also funded by Government of Navarre, Spain . Open access funding provided by Universidad Pública de Navarra, Spain .
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Inclusion of a supercapacitor energy storage system in DFIG and full-converter PMSG wind turbines for inertia emulation

  • Berrueta Irigoyen, Alberto
  • Sacristán Sillero, Javier
  • López Taberna, Jesús
  • Rodríguez Izal, José Luis
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
The energy transition towards renewables must be accelerated to achieve climate targets. To do so, renewable power plants, such as wind power plants (WPPs) must replace conventional power plants (CPPs). Transmission System Operators require this replacement to be made without weakening the frequency response of power systems, so it must be ensured that WPPs match the response of CPPs to grid frequency variations. CPPs consist of grid-tied synchronous generators that inherently react to frequency variations by modifying their stored kinetic energy and their output power, thereby contributing to grid stability. Such response is known as inertial response. By contrast, wind turbines (WTs) are mostly based on either doubly-fed induction generators (DFIG) or permanent magnet synchronous generators (PMSG). Their power electronics interface decouples the electromechanical behavior of the generator from the power grid, leading to a negligible inertial response. Therefore, in order to replace CPPs with WPPs, WTs must be able to react to frequency variations by changing their output power, i.e., emulating an inertial response. Currently implemented inertia emulation strategies in WTs rely on pitch control and stored kinetic energy variation. This paper proposes an alternative strategy, using the energy stored in a supercapacitor directly connected to the back-to-back converter DC link to emulate inertia. Its performance is validated by means of simulation for both DFIG and PMSG. Compared to state-of-the-art techniques, it allows a more accurate emulation of grid-tied synchronous generators, favoring the replacement of these generators by WTs., This work was supported in part by Siemens Gamesa Renewable Energy, in part by the Spanish State Research Agency, AEI/10.13039/501100011033 under Grants PID2019- 111262RB-I00 and PID2019-110956RB-I00, and in part by the Government of Navarre under Grant 0011-1411-2022-000049 through EnVeNA Project.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

On the characterization of lithium-ion batteries under overtemperature and overcharge conditions: identification of abuse areas and experimental validation

  • Lalinde Sainz, Iñaki
  • Berrueta Irigoyen, Alberto
  • Arza, Joseba
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
Although lithium-ion batteries have gained considerable popularity in renewable energy and electric vehicle applications, their safety still remains a concern under certain voltage, temperature, or state of charge conditions. This can lead to degradation and potential thermal runaway. In order to improve the safety assessment of LIBs based on their operating conditions, it is therefore essential to analyze not only their safe operating area but also their abuse region. This study focuses on the characterization of the abuse region of lithium-ion batteries by proposing a new methodology in which four areas of abuse are identified and experimentally validated using a commercial 3.6 Ah pouch cell. The cell is subjected to overtemperature and overcharge conditions, exploring various states of charge (0 to 200%) and ambient temperatures (25 to 100 °C). The influence of temperature and state of charge on the battery's behavior is thoroughly analyzed to fully characterize the abuse region. Results reveal the limiting temperatures and states of charge that define the boundaries of the abuse areas. By extending the characterization of LIBs behavior beyond the safe operation area with the determination of four areas of abuse, this article contributes to a better understanding of the phenomena and abuse mechanisms produced by overtemperature and overcharge events with an eye to improving battery safety., This work is part of the projects PID2019-111262RB-I00, funded by MCIN/AEI/10.13039/501100011033/, TED2021-132457B-I00, funded by MCIN/AEI/10.13039/501100011033/ and by the European Union “NextGenerationEU/PRTR”, STARDUST, funded by European Union’s Horizon 2020 research and innovation program, HYBPLANT, Spain (0011-1411-2022-000039), funded by Government of Navarre, Spain, and a Ph.D. scholarship (PRE2020-095314), funded by Spanish Ministry of Science and Innovation. Open access funding provided by Universidad Pública de Navarra, Spain.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Non-invasive aging analysis of lithium-ion batteries in extreme cold temperatures

  • Soto Cabria, Adrián
  • Berrueta Irigoyen, Alberto
  • Oficialdegui, Ignacio
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
This paper presents a non-invasive technical analysis of the degra-dation of four lithium-ion batteries (LIBs) used in extreme frigid weather. In contrast to other studies in which the batteries were tested in laboratory conditions, the LIBs studied in this paper were aged in a real application, more specifically in the WindSled project. In this project, an expedition was made using a zero-emission vehicle drawn by kites, covering more than 2500 kilometers on the East Antarctic Plateau. The study performed in this paper aims to quantify the degradation of the LIBs during the expedition. The results show a 5 % capacity fade, a 30 % increase in the internal resistance and no substantial increase in the impedance of the solid electrolyte interface (SEI). Moreover, no evidence of dendrite growth at the anode is inferred by the interpretation of the distri-bution of relaxation times (DRT), incremental capacity analysis (ICA) and differential voltage analysis (DV). Based on these re-sults, it can be claimed that the LIBs used in the WindSled Project can successfully operate under 50 C. Furthermore, since non-invasive techniques were used to characterize the batteries, they can still be used in upcoming expeditions, with subsequent financial and environmental benefits., This work was supported in part by the Spanish State Research Agency (AEI) under Grant PID2019-111262RB-I00/AEI/10.13039/501100011033, in part by the European Union under the H2020 Project STARDUST under Grant 774094, and in part by the Public University of Navarre through the research project ReBMS PJUPNA1904 and a Ph.D. Scholarship.