Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Automatic estimation of surface and probe location for 3D imaging with bidimensional arrays

  • Cosarinsky, Guillermo
  • Cruza, Jorge F.
  • Muñoz, Mario
  • Camacho Sosa-Días, Jorge
17 páginas, 22 figuras, 5 tablas, Ultrasound imaging for Non Destructive Testing is frequently performed in an immersion setup, where water is used as coupling medium between the probe and the component under test. For the computation of the time delays needed for beam-forming, the shape of the component surface and probe location and orientation (PLO) must be known. In this work we develop methods for the automatic detection of the surface and the estimation of PLO for 2D array probes. In particular, the methods developed apply to three types of elementary surfaces which are usually found in industrial and structural components: planes, cylinders and spheres. The methods use the measured surface echoes Time of Flight (TOF) to fit parametric models based on ray propagation and reflection on the surface, giving the coordinates and Euler angles that define the PLO relative to the component under test. Validation experiments with four test specimens representing the three types of surfaces are presented. The accuracy and precision of estimated PLO coordinates and angles are analyzed, and a Total Focusing Method (TFM) imaging example is shown achieving a correct detection of artificial defects in the component for a different PLOs., This research was supported by the projects PDC2022-133504-I00 founded by MCIN/AEI/10.13039/501100011033 (Spain) and ‘‘Next Generation EU’’/PRTR (European Union), by the fellowship PRE2019- 088602 founded by MCIU (Spain) and by the project PID2022- 143271OB-I00, founded MCIN/AEI /10.13039/501100011033/FEDER, UE
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Deep Learning-Based Algorithms for Real-Time Lung Ultrasound Assisted Diagnosis

  • Muñoz, Mario
  • Rubio, Adrián
  • Cosarinsky, Guillermo
  • Cruza, Jorge F.
  • Camacho Sosa-Días, Jorge
Lung ultrasound is an increasingly utilized non-invasive imaging modality for assessing lung condition but interpreting it can be challenging and depends on the operator’s experience. To address these challenges, this work proposes an approach that combines artificial intelligence (AI) with feature-based signal processing algorithms. We introduce a specialized deep learning model designed and trained to facilitate the analysis and interpretation of lung ultrasound images by automating the detection and location of pulmonary features, including the pleura, A-lines, B-lines, and consolidations. Employing Convolutional Neural Networks (CNNs) trained on a semi-automatically annotated dataset, the model delineates these pulmonary patterns with the objective of enhancing diagnostic precision. Real-time post-processing algorithms further refine prediction accuracy by reducing false-positives and false-negatives, augmenting interpretational clarity and obtaining a final processing rate of up to 20 frames per second with accuracy levels of 89% for consolidation, 92% for B-lines, 66% for A-lines, and 92% for detecting normal lungs compared with an expert opinion., This research was partially supported by the project PID2022-143271OB-I00, founded MCIN/AEI/10.13039/501100011033/FEDER, UE and by the fellowship PRE2019-088602 founded by MCIU (Spain)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Three-Dimensional Convolutional Neural Network for Ultrasound Surface Echo Detection

  • Muñoz, Mario
  • Rubio, Adrián
  • Larrea, Marcelo
  • Cruza, Jorge F.
  • Camacho Sosa-Días, Jorge
  • Cosarinsky, Guillermo
This article belongs to the Special Issue Ultrasonic Imaging and Sensors II., Ultrasound array imaging frequently employs a coupling medium to facilitate wave transmission from the transducer to the target component. Surface echoes, identified by their high-amplitude peaks, are crucial for determining the Time of Flight (TOF) in each channel, which is essential for deriving imaging focal laws. Accurate TOF measurement is vital in numerous applications, such as Non-Destructive Testing (NDT) and medical imaging. Conventional methods, such as threshold crossing and peak search, are highly sensitive to noise and spurious signals, therefore, more robust estimation techniques are needed. This study explores the application of a deep 3D Convolutional Neural Network (CNN) to detect surface echoes in Full Matrix Capture (FMC) ultrasound data. The CNN was trained on signals obtained with a matrix array and a set of reference components, utilizing a robotic arm setup to ensure precise probe positioning. Theoretical TOFs were computed based on the setup geometry to generate labeled training data. Test results indicated that the CNN model, which we have called DeepEcho3D, closely aligned with the ground truth and significantly reduced TOF estimation outliers (up to 98%) compared to traditional methods, demonstrating its potential for improved accuracy in surface echo detection., This research was supported by the project PID2022-143271OB-I00, funded by MCIN/AEI/10.13039/501100011033/FEDER, UE, the project 202450E192, funded by CSIC, the project PLEC2024-011165, funded by MICIU/AEI/10.13039/501100011033/FEDER, UE, and by the European Commission—NextGenerationEU, through Momentum CSIC Programme: Develop Your Digital Talent. The funding for these actions/grants and contracts comes from the European Union’s Recovery and Resilience Facility—Next Generation, in the framework of the General Invitation of the Spanish Government’s public business entity Red.es to participate in talent attraction and retention programs within Investment 4 of Component 19 of the Recovery, Transformation and Resilience Plan. G. COSARINKSY STAFF hired under the Generation D initiative, promoted by Red.es, an organization attached to the Ministry for Digital Transformation and the Civil Service, for the attraction and retention of talent through grants and training contracts, financed by the Recovery, Transformation and Resilience Plan through the European Union’s Next Generation funds., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Free-form surface reconstruction for adaptive imaging with 2D ultrasound arrays

  • Cosarinsky, Guillermo
  • Cruza, Jorge F.
  • Muñoz, Mario
  • Rubio, Adrián
  • Camacho Sosa-Días, Jorge
This research was supported by the project PID2022-143271OB- I00, funded by MCIN/AEI /10.13039/501100011033/FEDER, UE., the project PLEC2024-011165, funded by MICIU/AEI/10.13039/ 501100011033/ FEDER, UE , and by the European Commission – NextGenerationEU, through Momentum CSIC Programme: Develop Your Digital Talent. The funding for these actions/grants and contracts comes from the European Union’s Recovery and Resilience Facility- Next Generation, in the framework of the General Invitation of the Spanish Government’s public business entity Red.es to participate in talent attraction and retention programmes within Investment 4 of Component 19 of the Recovery, Transformation and Resilience Plan. G. Cosarinsky staff is hired under the Generation D initiative, pro- moted by Red.es, an organization attached to the Ministry for Digital Transformation and the Civil Service, for the attraction and retention of talent through grants and training contracts, financed by the Recovery, Transformation and Resilience Plan through the European Union’s Next Generation funds, This paper introduces the Aperture Interpolation Method (AIM) for free-form surface reconstruction using 2D ultrasound arrays. Surface reconstruction plays an essential role in adaptive imaging methods, allowing for effective operation even with imprecise or unknown system geometries. The AIM method leverages the time of flight (TOF) of echos from surface reflections to estimate the surface geometry of a component under test, without requiring a pre-existing component model. In this paper we present the theoretical basis of AIM for three acquisition modes: pulse-echo, pitch-catch, and plane wave. Experimental validation is performed using a complex-shaped aluminum test piece scanned with an 11x11, 3MHz matrix array mounted on a robotic arm. The ultrasonically reconstructed surface is compared with laser scanning data for accuracy analysis. Furthermore, the ultrasonically measured surface data is used to generate Total Focusing Method (TFM) images of the component, which are then compared against micro-CT images for validation. The experimental results validate the AIM method’s capability to accurately reconstruct surfaces, facilitating reliable imaging of the components defects, thereby demonstrating its potential applicability in industrial settings., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Evaluating deep learning approaches for AI-assisted lung ultrasound diagnosis: an international multi-center and multi-scanner study

  • Muñoz, Mario
  • Han, Xi
  • Camacho Sosa-Días, Jorge
  • Perrone, Tiziano
  • Smargiassi, Andrea
  • Inchingolo, Riccardo
  • Tung-Chen, Yale
  • Demi, Libertario
18 páginas, 11 figuras, 7 tablas, Lung ultrasound (LUS) interpretation is often subjective and operator-dependent, motivating the development of automated, artificial intelligence (AI)-based methods. This international, multi-center study evaluated two distinct deep learning approaches for automated LUS severity scoring for pulmonary infections caused by COVID-19: a pre-trained classification model (CM) and a segmentation model based method (SM); assessing performance at video, exam, and prognostic levels. Two datasets were analyzed: one comprising data from multiple scanners and another using data from a single scanner. Results showed that the SM achieved prognostic-level agreement with expert clinicians comparable to that of the CM. Furthermore, at the exam level, over 84% of examinations were classified with acceptable error (≤ 10 score difference) across both models and datasets, reaching both methods an agreement higher than 95% on the dataset acquired by a single scanner. The obtained results demonstrate the potential of AI-assisted LUS for reliable prognostic assessment and highlight that image quality and acquisition technique are key factors in achieving consistent and generalizable model performance, as well as the potential for international clinical translations., This research was partially supported by the project PID2022-143271OB-I00, founded MCIN/AEI /h t t ps : // d o i. org /1 0 .1 3 0 39 /5 0 1 1 0 0 0 1 1 0 3 3 / FEDER, UE and by the fellowship IMOVE24246 founded by CSIC (Spain). As well as by the grant Hub Life Science Advanced Diagnosis (HLS-AD), PNRR PNC-E3-2022- 23683266 PNC HLS-DA, INNOVA–CUP: E63C22003780001, funded by the Italian Ministry of Health under the National Complementary Plan Innovative Health Ecosystem—Unique Investment Code: PNC-E.3, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Plane Wave Imaging with Large-Scale 2D Sparse Arrays: A Method for Near-Field Enhancement via Aperture Diversity

  • Martínez-Graullera, Óscar
  • Camacho Sosa-Días, Jorge
  • Huecas, Jorge
  • Cosarinsky, Guillermo
  • Elvira Segura, Luis
  • Parrilla Romero, Montserrat
31 páginas, 28 figuras, 2 tablas, In the context of a medical imaging application for preclinical research, specifically cere- brovascular imaging in small animals, this work addresses the challenges associated with using a large-scale 2D ultrasonic array comprising 32 × 32 elements (96λ × 96λ ). The application imposes stringent requirements: operation in the extreme near field, high spatial resolution, high frequency, high frame rate, and imaging within a highly attenu- ating medium. These demands, combined with current technological limitations, such as element size and constraints on the number of channels that can be driven in parallel, present significant challenges for system design and implementation. To assess system performance, plane wave imaging is employed as a reference modality due to its ability to meet high acquisition speed requirements. Our analysis reveals limitations in spatial coverage and image quality when operating the full aperture under plane wave trans- mission constraints. To address these limitations, we propose a sparse aperture strategy. When combined with advanced signal processing techniques, this approach enhances both contrast and resolution while preserving acquisition speed, making it a promising solution for high-performance ultrasonic imaging under the demanding conditions of preclinical research., Jorge Huecas and Guillermo Cosarinsky, Staff hired under the Generation D initiative, promoted by Red.es, an organisation attached to the Ministry for Digital Transformation and the Civil Service, for the attraction and retention of talent through grants and training contracts, financed by the Recovery, Transformation and Resilience Plan through the European Union’s Next Generation funds. This research work was funded by the European Commission–NextGenerationEU, through Momentum CSIC Programme: Develop Your Digital Talent. This research work was funded by: PID2022-138013OB-I00, MCIN/AEI /10.13039/501100011033/FEDER, UE. This research work was funded by: PID2022-143271OB-I00, MCIN/AEI /10.13039/501100011033/FEDER, UE. This work has been developed within the framework of the TEC-2024/TEC-43 LUNABRAIN-CM project, funded with 1.026 million by the Community of Madrid through the R&D activities program in technologies, granted by Order 5696/2024., Peer reviewed