Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Optimized auto-focusing method for 3D ultrasound imaging in NDT

  • Cosarinsky, Guillermo
  • Cruza, Jorge F.
  • Muñoz, Manuel
  • Camacho Sosa-Días, Jorge
14 páginas, 14 figuras, 1 tabla, In this work, we propose an optimized auto-focusing algorithm to be used with ultrasound matrix arrays for three-dimensional imaging in the presence of interfaces. Its main application is for non-destructive-testing (NDT), where usually two mediums with different propagation velocities are present. The refraction at the interface between those mediums complicates the calculation and the application of the focusing delays, which requires iterative processes that are usually the main bottleneck for high-speed inspections. We tackle this problem by generalizing the virtual array concept previously proposed for linear arrays and plane images to the case of matrix-arrays and three-dimensional (3D) beamforming. Furthermore, we propose a two-dimensional iterative algorithm for exact time-of-flight calculation to the two foci per scan line required by the virtual array. The mathematical formulation for the 3D case is obtained and the time-delay errors are analyzed by simulation. Finally, image quality with the proposed method is compared with that obtained with conventional Total Focusing Method (TFM) and exact delay calculation. The principal conclusion is that the virtual array approach generates images with equivalent quality to those obtained by exact calculation, while it reduces more than two orders of magnitude the computation load., This research was supported by the project PDC2022-133504-I00 founded by MCIN/AEI/10.13039/501100011033 (Spain) and “Next Generation EU”/PRTR (European Union) and by the fellowship CIU founded by MCIU (Spain)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Automatic estimation of surface and probe location for 3D imaging with bidimensional arrays

  • Cosarinsky, Guillermo
  • Cruza, Jorge F.
  • Muñoz, Mario
  • Camacho Sosa-Días, Jorge
17 páginas, 22 figuras, 5 tablas, Ultrasound imaging for Non Destructive Testing is frequently performed in an immersion setup, where water is used as coupling medium between the probe and the component under test. For the computation of the time delays needed for beam-forming, the shape of the component surface and probe location and orientation (PLO) must be known. In this work we develop methods for the automatic detection of the surface and the estimation of PLO for 2D array probes. In particular, the methods developed apply to three types of elementary surfaces which are usually found in industrial and structural components: planes, cylinders and spheres. The methods use the measured surface echoes Time of Flight (TOF) to fit parametric models based on ray propagation and reflection on the surface, giving the coordinates and Euler angles that define the PLO relative to the component under test. Validation experiments with four test specimens representing the three types of surfaces are presented. The accuracy and precision of estimated PLO coordinates and angles are analyzed, and a Total Focusing Method (TFM) imaging example is shown achieving a correct detection of artificial defects in the component for a different PLOs., This research was supported by the projects PDC2022-133504-I00 founded by MCIN/AEI/10.13039/501100011033 (Spain) and ‘‘Next Generation EU’’/PRTR (European Union), by the fellowship PRE2019- 088602 founded by MCIU (Spain) and by the project PID2022- 143271OB-I00, founded MCIN/AEI /10.13039/501100011033/FEDER, UE
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Deep learning for ultrasound surface echo detection

  • Cosarinsky, Guillermo
  • Muñoz, Mario
  • Fernández Cruza, Jorge
  • Rubio, Adrián
  • Camacho Sosa-Días, Jorge
20th World Conference for Non-Destructive Testing (WCNDT), 27-31 May 2024, Songdo Convensia, Incheon, Korea. 9 páginas, 6 figuras, 1 tabla., Ultrasound array imaging techniques are often applied using a coupling medium to transmit waves from the transducer to the scanned component. In this type of tests, the echoes generated by the wave reflection at the component surface contain information that can be used to estimate the surface shape and its position relative to the probe, which are needed to compute the imaging focal laws. The most interesting feature to extract from surfaces echoes is the Time of Flight (TOF) for each reception channel. TOF measurement in acoustic signals is a problem that frequently arises not only in Non Destructive Testing (NDT), but also in medical imaging, geophysics and other fields. The surface echo in a signal is usually identified as the first high amplitude peak, and is traditionally detected with standard methods as threshold crossing, peak search or matched filters. All these methods are easily affected by Signal to Noise Ratio, which might be high in some channels, for example if the ray arrives at the corresponding element at a low sensibility angle. Moreover, spurious echoes from bubbles, the emission signal tail or echoes from other parts of the component can be incorrectly labelled as surface echoes. This kind of outliers are difficult to filter by conventional means and, thus, there is a need for more robust surface estimation methods. In this work, we study the application of a deep 3D Convolutional Neural Network (CNN) to detect surface echoes in Full Matrix Capture (FMC) ultrasound data. The CNN is trained using signals acquired with a matrix array and a reference component, using a robotic arm set-up to measure the probe position and orientation relative to the component. Thus, with knowledge of the set-up geometry, a model is used to compute the theoretical surface echo TOFs, which are used to label the data for training. The model was tested with a validation set, presenting good agreement with the ground truth. The results were compared with the threshold crossing method observing a significant reduction of outliers in the TOF estimation., This research was supported by the projects PDC2022-133504-I00 founded by MCIN/AEI/10.13039/501100011033 (Spain) and “Next Generation EU”/PRTR (European Union), by the fellowship PRE2019-088602 founded by MCIU (Spain) and by the project PID2022-143271OB-I00, founded MCIN/AEI /10.13039/501100011033/FEDER, UE, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Time of flight fast approximation method for ultrasound sub-surface imaging

  • Cosarinsky, Guillermo
  • Muñoz, Mario
  • Cruza, Jorge F.
  • Camacho Sosa-Días, Jorge
6 páginas, 5 figuras, Time-Of-Flight (TOF) computations are needed in all ultrasound imaging methods. In Non Destructive Testing (NDT), where ultrasound inspections are frequently done using a coupling medium between the transducer and the test piece, wave refraction complicates TOF computations and iterative methods are needed, which hinders frame rate. For fast imaging simple approximation methods are needed. In this work we propose a TOF fast approximation method for the particular case of sub-surface imaging., This research was supported by the project PDC2022-133504-I00 founded by MCIN/AEI/10.13039/501100011033 (Spain) and “Next Generation EU”/PRTR (European Union) and by the fellowship PRE2019-088602 founded by MCIU (Spain)., Peer reviewed