Pasar al contenido principal

MATERIALES 2D PARA APLICACIONES ELECTROQUIMICAS EN EL ALMACENAMIENTO Y CONVERSION DE ENERGIA

PID2022-137566OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ALICANTE

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Rapid electrochemical readout of alkaline phosphatase activity and phosphate inhibition in silica films

  • Sáenz-Espinar, MJ
  • Montilla, Francisco
  • Mateo, C. Reyes
  • Huerta, Francisco|||0000-0002-9791-0355
[EN] This work introduces a bioelectrochemical platform for the rapid electrochemical readout of alkaline phosphatase (ALP) activity based on enzyme entrapment within sol¿gel silica films deposited on glassy carbon electrodes. Fluorescence spectroscopy confirms that immobilization preserves the structural integrity of the enzyme while creating a confined microenvironment within the silica matrix. Electrochemical experiments show that the enzymatic hydrolysis of hydroquinone diphosphate generates hydroquinone inside the film, which is detected voltammetrically at the electrode surface. The steady-state oxidation current provides a direct electrochemical readout of the enzymatic reaction rate, allowing the system response to be described using a modified Michaelis¿Menten framework in the presence of phosphate as a competitive inhibitor. The estimated activity should be regarded as an apparent specific activity of the immobilized ALP, reflecting the fraction of enzyme effectively contributing to substrate conversion and electrochemical product detection within the silica-film/ electrode. An apparent inhibition constant of 3.64 mM was obtained, in good agreement with reported values for ALP in solution, indicating that the film architecture largely preserves the native enzyme¿inhibitor interaction. The use of glassy carbon electrodes enables repeated measurements in different solutions using the same biofunctionalized electrode, providing a practical advantage over disposable screen-printed electrode configurations previously employed for ALP-based inhibition assays., Authors would like to thank the Spanish Ministerio de Ciencia e Innovacion (MICIU/AEI/ 10.13039/501100011033) for financial support of PID2022-138507OB-I00 and PID2022-137566OB-I00 grants, and Generalitat Valenciana (CIPROM/2021/62 project)