Corrosion Behaviour and J774A.1 Macrophage Response to Hyaluronic Acid Functionalization of Electrochemically Reduced Graphene Oxide on Biomedical Grade CoCr

  • Chico, Belén
  • Pérez-Maceda, B. T.
  • San José-Pinilla, Sara
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
Improvements in the lubrication of metal¿metal joint prostheses are of great clinical interest in order to minimize the particles released during wear¿corrosion processes. In this work, electrochemically reduced graphene oxide (ErGO) on CoCr was functionalized with hyaluronic acid (ErGOHA). Functionalization was carried out by soaking for 24 h in phosphate buffer saline (PBS) solution containing 3 g/L hyaluronic acid (HA). The corrosion performance of CoCrErGO and CoCrErGOHA surfaces was studied by electrochemical impedance spectroscopy (EIS) for 7 days in PBS. Biocompatibility and cytotoxicity were studied in mouse macrophages J774A.1 cell line by the measurement of mitochondrial activity (WST-1 assay) and plasma membrane damage (LDH assay). The inflammatory response was examined through TNF-¿ and IL-10 cytokines in macrophages culture supernatants, used as indicators of pro-inflammatory and anti-inflammatory responses, respectively. EIS diagrams of CoCrErGOHA revealed two time constants: the first one, attributed to the hydration and diffusion processes of the HA layer adsorbed on ErGO, and the second one, the corrosion resistance of ErGOHA/CoCr interface. Macrophage assays showed better behavior on CoCrErGOHA than CoCr and CoCrErGO surfaces based on their biocompatible, cytotoxic, and inflammatory responses. Comparative analysis of IL-10 showed that functionalization with HA induces higher values of anti-inflammatory cytokine, suggesting an improvement in inflammatory behavior., Financial support received through the RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación y Universidades (MICIU/FEDER), and through the MAT2015-67750-C3-2-R, MAT2015-67750-C3-1-R from the Ministerio de Economía y Competitividad (MINECO/FEDER) from Spain.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Corrosion rates of reabsorbable Mg-based materials coated with phytic acid

  • Hernández Alvarado, Laura Angélica
  • Salvador Hernandez, L.
  • Lomelí, M. A.
  • Miranda-Vidales, J. M.
  • Narváez, L.
  • Escudero Rincón, María Lorenza
The development of temporary protective coatings on magnesium implants is a priority in the biomedical field. In the present study, corrosion rates were determined by various techniques for powder metallurgy Mg and AZ31 magnesium alloy uncoated and coated with phytic acid (PA). Weight loss measurements, potentiodynamic polarisation, and electrochemical impedance spectroscopy were performed to monitor the corrosion evolution in a phosphate-buffered saline solution at 37°C. The corrosion rates of all samples determined from weight losses were higher than those obtained by electrochemical techniques. According to electrochemical data, the initial corrosion current density of the coated samples decreased by three orders of magnitude as compared with that of the bare substrates. However, the protective effect weakened with the testing time due to the presence of microcracks in the PA conversion coating, which indicated the potential applicability of the coated AZ31 alloy as a biodegradable and resorbable temporary implant material for bone repair., This work was supported by the Spanish Ministry of Science, Innovation and Universities [RTI2018- 101506-B-C31]. The authors would like to thank Dr. S. Feliu Battle for his valuable comments and suggestions.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Wettability, corrosion resistance, and osteoblast response to reduced graphene oxide on CoCr functionalized with hyaluronic acid

  • Chico, Belén
  • Pérez-Maceda, B. T.
  • San José-Pinilla, Sara
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
14 p.-8 fig.-2 tab. Blanca Teresa Pérez-Maceda who participated actively in this research with great enthusiasm has passed away., The durability of metal–metal prostheses depends on achieving a higher degree of lubrication. The beneficial effect of hyaluronic acid (HA) on the friction and wear of both natural and artificial joints has been reported. For this purpose, graphene oxide layers have been electrochemically reduced on CoCr surfaces (CoCrErGO) and subsequently functionalized with HA (CoCrErGOHA). These layers have been evaluated from the point of view of wettability and corrosion resistance in a physiological medium containing HA. The wettability was analyzed by contact angle measurements in phosphate buffer saline-hyaluronic acid (PBS-HA) solution. The corrosion behavior of functionalized CoCr surfaces was studied with electrochemical measurements. Biocompatibility, cytotoxicity, and expression of proteins related to wound healing and repair were studied in osteoblast-like MC3T3-E1 cell cultures. All of the reported results suggest that HA-functionalized CoCr surfaces, through ErGO layers in HA-containing media, exhibit higher hydrophilicity and better corrosion resistance. Related to this increase in wettability was the increase in the expressions of vimentin and ICAM-1, which favored the growth and adhesion of osteoblasts. Therefore, it is a promising material for consideration in trauma applications, with improved properties in terms of wettability for promoting the adhesion and growth of osteoblasts, which is desirable in implanted materials used for bone repair, Financial support is received through the RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación (MICINN/FEDER), and through the MAT2015-67750-C3-2-R, MAT2015-67750-C3-1-R from the Ministerio de Economía y Competitividad (MINECO/FEDER) from Spain., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Biological Responses in the Blood and Organs of Rats to Intraperitoneal Inoculation of Graphene and Graphene Oxide

  • Aguado-Henche, Soledad
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
  • Clemente de Arriba, Celia
Background: The discrepancy among the in vivo results found in the literature regarding graphene’s side effects led us to conduct an in vivo study with graphene. Methods: In vivo tests involving intraperitoneal inoculation of graphene and graphene oxide nanosheets in rats were carried out to assess potential changes in the blood and organs after 15 and 30 days. Graphene and graphene oxide nanosheets at a concentration of 4 mg per kilogram were suspended in an aqueous solution of 0.9% NaCl at a 1:1 proportion (graphene or graphene oxide), i.e., 1 mg/mL. Results: Optical microscopy of liver, kidney, spleen, and lung tissues revealed no visible histological changes. However, particle traces were found in the peritoneal cavity. Thirty days after inoculation, blood samples were collected for hematological analysis. The blood analysis showed changes indicating a hepatic inflammatory process. Hematological changes after 30 days consisted of alterations to the red series, including microcytosis or higher mean hemoglobin concentrations. In addition, changes in prothrombin and thromboplastin caused longer coagulation times. Conclusion: This study contributes to further clarifying the possible toxicity of graphene and its potential biomedical applications., This research was funded by the “Spanish Ministry of Economy, Industry and Competitiveness” [MAT2015-67750-C31;32;33-R] and the “Spanish Ministry of Science, Innovation and Universities” [RTI2018-101506-B-C31;32;33].
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Covalent immobilization of graphene oxide on biomedical grade CoCr alloy by an improved multilayer system assembly via Silane/GO bonding

  • Sánchez-López, Luna
  • Chico, Belén
  • Llorente, Irene
  • Escudero Rincón, María Lorenza
  • Lozano, R.M.
  • García-Alonso, M. C.
Improvements in durable lubrication together with minimized wear are essential for obtaining long-term, functioning metallic joint prostheses. To achieve this objective, CoCr surface was functionalized with Graphene Oxide (GO) and characterized by FTIR and XPS. CoCr alloy was subjected to alkalinization in order to generate high hydroxyl content on the surface. FTIR and XPS revealed reactive OH groups, enabling intermediate coupling via (3-aminopropyl) triethoxysilane (APTES), which was cured at 45 °C and 75 °C for 24 h and 30 min, respectively. FTIR revealed cross-linked films (Si–O–Si), inferring condensation and self-assembly of silane layers, while XPS revealed the presence of NH, enabling chemical binding of GO. Silane-coated CoCr disks were immersed in GO solution at 60 °C for 12h and 24h, respectively. FTIR displayed C[dbnd]C band confirming the assembly of GO on silane-coated CoCr surfaces. XPS revealed three possible surface mechanisms: (1) reaction between primary amines of APTES and epoxy groups of GO; (2) free –OH groups in APTES and carboxyl groups in GO; and (3) reaction between APTES primary amines and –OH from carboxyl groups of GO. Overall, the multilayer system CoCr–OH–Si45-GO24h showed covalent functionalization of metal substrate with GO to a large extension of surface area among all the multilayer systems studied., This work was supported through RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerial de Ciencia, Innovación y Universidades (MICIU/FEDER).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Implantation of heat treatment Ti6al4v alloys in femoral bone of Wistar rats

  • Chávez-Díaz, Mercedes Paulina
  • Aguado-Henche, Soledad
  • Rubio Yanchuck, Mónica
  • Clemente de Arriba, Celia
  • Cabrera Sierra, Román
  • Escudero Rincón, María Lorenza
  • Hallen, José M.
Two heat treatments were carried out at below (Ti6Al4V) and above (Ti6Al4V) the beta-phase transformation temperature (T = 980 °C), to study the effect of microstructural changes on osseointegration. The alloys were implanted in the femurs of hind legs of Wistar rats for 15, 30, and 60 days. Histology of the femur sections obtained for the first 15 days showed inflammatory tissue surrounding the implants and tissue contraction, which prevented osseointegration in early stages. After 30 days, trabecular bone, reduction of inflammatory tissue around the implants, and osseointegration were observed in Ti6Al4V as received and Ti6Al4V alloys, while osseointegration was detected for the three alloys after 60 days. These results were supported through morphometric studies based on the analysis of Bone Implant Contact (BIC), where there was a larger bone contact after 60 days for the Ti6Al4V alloy; indicating that microstructural features of the Ti6Al4V alloys influence their osseointegration, with the lamellar microstructure (Ti6Al4V), being the most responsive. [Figure not available: see fulltext.]., This work was supported by the Government of Spain, through the Ministry of Economy and Competitiveness RTI2018‐101506‐B‐C31 and MAT2015-67750-C3-1.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Synthesis and characterisation of CeO2 coatings on the AZ31 alloy for corrosion protection and in vitro biocompatibility of MC3T3-E1 pre-osteoblasts

  • Benito-Santiago, Sandra E.
  • Onofre-Bustamante, E.
  • Lozano, R.M.
The use of bioabsorbable metals as temporary medical implants has attracted considerable research interest as they do not require a second surgical operation for removal after the healing process is completed. However, magnesium (Mg) and its alloys have a degradation rate that is too high in biological environments. Therefore, it must be controlled using various strategies. In this study, an AZ31-Mg-based alloy coated with CeO2 is investigated to analyse the effect of the coating on its corrosion protection and biocompatibility. The AZ31 alloy is anodised with NaOH solution, before coating to stabilise the alloy surface. The CeO2 coating is deposited on anodised AZ31 by chemical conversion treatment. The electrochemical properties of samples are evaluated using electrochemical impedance spectroscopy and cyclic polarisation curves using Hank’s solution. Structural and morphological characterisation of the samples are performed using X-ray diffraction and scanning electron microscopy–energy dispersive X-ray spectroscopy. Additionally, biocompatibility is determined by live/dead assay using MC3T3-E1 pre-osteoblasts. The preliminary results indicate that CeO2 coatings exhibit higher electrochemical properties. Additionally, an increase in the ratio of live/dead cells of the AZ31OH-CeO2 surface is detected, in contrast with AZ31, thus indicating improvement in biocompatibility upon CeO2 coating., This work was financed by a Consejo Nacional de Ciencia y Tecnología (CONACYT) Science Grant. SIP project 20221194 through the Instituto Politécnico Nacional. Financial support from ICOOP 2021 Ref COOPA20479 of the Consejo Superior de Investigaciones Científicas (CSIC) and from the Spanish Ministry of Science, Innovation and Universities (RTI2018-101506-B-C31C33) is gratefully acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effect of wear-corrosion of reduced graphene oxide functionalized with hyaluronic acid on inflammatory and proteomic response of J774A.1 macrophages

  • Sánchez-López, Luna
  • Ropero de Torres, N.
  • Chico, Belén
  • Fagali, Natalia S.
  • Ríos, Vivian de los
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
The presence of a worn surface in the implanted material, as in the case of a replacement of a damaged osteoarticular joint, is the normal condition after implantation. This manuscript focuses precisely on the comparative study of the cellular behavior on worn CoCr surfaces, analyzing the effect of different surface modifications on macrophages¿ responses. CoCr surfaces were modified by the deposition of electrochemically reduced graphene oxide (CoCrErGO), followed by additional surface functionalization with hyaluronic acid (CoCrErGOHA). After the wear corrosion processes, the macrophage response was studied. In addition, macrophage supernatants exposed to the surfaces, before and after wear, were also evaluated for osteoblast response through the analysis of the metabolic activity, plasma membrane damage, and phosphatase alkaline activity (ALP). The proteomic analysis and the quantitative TNF-¿/IL-10 ratios of the J774A.1 macrophages exposed to the surfaces under study showed a polarization shift from M0 (basal state) to M1, associated with the pro-inflammatory response of all surfaces. A lower M1 polarization was observed upon exposure to the surface modification with ErGO, whereas posterior HA functionalization attenuated, even more, the M1 polarization. The wear corrosion process contributed to inflammation and exacerbated the M1 polarization response on macrophages to CoCr, which was diminished for the ErGO and attenuated the most for the ErGOHA surfaces. Comparative proteomics showed that the pathways related to M1 polarization were downregulated on the surfaces of CoCrErGOHA, which suggests mechanisms for the observed attenuation of M1 polarization. The suitable immuno-modulatory potential induced by the ErGOHA surface, with and without wear, together with the stimulation of ALP activity in osteoblasts induced by macrophage supernatants, promotes the mineralization processes necessary for bone repair. This makes it feasible to consider the adsorption of ErGOHA on CoCr as a recommended surface treatment for the use of biomaterials in osseous joint applications., Financial support was received through the RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación y Universidades (MICIU/FEDER) in Spain. L. Sánchez-López thanks financial support from MICIU for the predoctoral contract PRE2019-090122. ANPCyT (PICT 2019-0631), CONICET (PIP 112-201501-00601CO and External Grant for Young Researchers for N.S.F.) and UNLP (11/X900)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Tribocorrosion behavior of graphene-based solid lubricants biofunctionalized with hyaluronic acid on CoCr surfaces

  • García-Alonso, M. C.
  • Chico, Belén
  • Lozano, R.M.
  • Escudero Rincón, María Lorenza
In this work graphene-based solid lubricants biofunctionalized with hyaluronic acid were deposited on CoCr surfaces to decrease wear-corrosion phenomena. Graphene oxide was electrochemically reduced on CoCr in an aqueous suspension of graphene oxide 4 g/L by cyclic voltammetry. Biofunctionalization in phosphate buffer solution with HA 3 g/L (PBS-HA) for 24 h was performed. A pin-on-disk tribometer with an integrated cell was used for tribocorrosion tests. Wear-corrosion tests were performed against AISI316 steel balls applying normal load 1 N, 120 rpm for 500 m, in PBS and PBS-HA. Coefficients of friction in PBS were higher than in PBS-HA. ErGO and HA-ErGO increased wear rate in AISI316 balls, i.e., ErGO hardens the CoCr surface. Bio- functionalization reduces abrasive properties of ErGO deposits., Funding: This work was supported by the Spanish Ministry of Science, Innovation and Universities [RTI2018–101506-B-C31, RTI2018–101506-B-C33]., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Macrophage proteomic analysis of covalent immobilization ofhyaluronic acid and graphene oxide on CoCr alloy in atribocorrosive environment

  • Sánchez-López, Luna
  • Chico, Belén
  • García-Alonso, M. C.
  • Lozano, R.M.
19 p.-10 fig.-2 tab., In this work, a sequential covalent immobilization of graphene oxide (GO) and hyaluronic acid (HA) is performed to obtain a biocompatible wear-resistant nanocoating on the surface of the biomedical grade cobalt-chrome (CoCr) alloy. Nanocoated CoCr surfaces were characterized by Raman spectroscopy and electrochemical impedance spectroscopy (EIS) in 3 g/L HA electrolyte. Tribocorrosion tests of the nanocoated CoCr surfaces were carried out in a pin on flat tribometer. The biological response of covalently HA/GO biofunctionalized CoCr surfaces with and without wear-corrosion processes was studied through the analysis of the proteome of macrophages. Raman spectra revealed characteristic bands of GO and HA on the functionalized CoCr surfaces. The electrochemical response by EIS showed a stable and protective behavior over 23 days in the simulated biological environment. HA/GO covalently immobilized on CoCr alloy is able to protect the surface and reduce the wear volume released under tribocorrosion tests. Unsupervised classification analysis of the macrophage proteome via hierarchical clustering and principal component analysis (PCA) revealed that the covalent functionalization on CoCr enhances the macrophage biocompatibility in vitro. On the other hand, disruption of the HA/GO nanocoating by tribocorrosion processes induced a macrophage proteome which was differently clustered and was distantly located in the PCA space. In addition, tribocorrosion induced an increase in the percentage of upregulated and downregulated proteins in the macrophage proteome, revealing that disruption of the covalent nanocoating impacts the macrophage proteome. Although macrophage inflammation induced by tribocorrosion of HA/GO/CoCr surfaces is observed, it is ameliorated by the covalently grafting of HA, which provides immunomodulation by eliciting downregulations in characteristic pro-inflammatory signaling involved in inflammation and aseptic loosening of CoCr joint arthroplasties. Covalent HA/GO nanocoating on CoCr provides potential applications for in vivo joint prostheses led a reduced metal-induced inflammation and degradation by wear-corrosion., This wok was supported by RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación y Universidades (MICIU/FEDER) in Spain. Author L. Sánchez-López has received financial support from MICIU for the predoctoral contract PRE2019-090122, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Hematological Response to Particle Debris Generated During Wear–Corrosion Processes of CoCr Surfaces Modified with Graphene Oxide and Hyaluronic Acid for Joint Prostheses

  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Chico, Belén
  • Lozano, R.M.
  • Sánchez-López, Luna
  • Flores-Sáenz, Manuel
  • Cristóbal-Aguado, Soledad
  • Moreno-Gómez-Toledano, Rafael
  • Aguado-Henche, Soledad
Various surface modifications to increase the lifespan of cobalt–chromium (CoCr) joint prostheses are being studied to reduce the wear rate in bone joint applications. One recently proposed modification involves depositing graphene oxide functionalized with hyaluronic acid (a compound present in joints) on CoCr surfaces, which can act as a solid lubricant. This paper analyzes the biological alterations caused by wear–corrosion phenomena that occur in joints, both from the perspective of the worn surface (in vitro model) and the particles generated during the wear processes (in vivo model). The analysis of the inflammatory response of macrophage was performed on CoCr surfaces modified with graphene oxide and functionalized with hyaluronic acid (CoCr-GO-HA), before and after wear–corrosion processes. The wear particles released during the wear–corrosion tests of the CoCr-GO-HA/CoCr ball pair immersed in 3 g/L hyaluronic acid were intra-articularly injected into the experimental animals. The hematological analysis in vivo was made considering a murine model of intra-articular injection into the left knee in male adult Wistar rats, at increasing concentrations of the collected wear particles dispersed in 0.9% NaCl. Non-significant differences in the inflammatory response to unworn CoCr-GO-HA surfaces and control (polystyrene) were obtained. The wear–corrosion of the CoCr-GO-HA disk increased the inflammatory response at both 72 and 96 h of material exposure compared to the unworn CoCr-GO-HA surfaces, although the differences were not statistically significant. The pro-inflammatory response of the macrophages was reduced on the worn surfaces of the CoCr modified and functionalized with graphene oxide (GO) and hyaluronic acid (HA), compared to the worn surfaces of the unmodified CoCr. The hematological analysis and tissue reactions after intra-articular injection did not reveal pathological damage, with average hematological values recorded, although slight reductions in creatinine and protein within non-pathological ranges were found. Some traces of biomaterial particles in the knee at the highest concentration of injected particles were only found but without inflammatory signs. The results show the potential benefits of using graphene in intra-articular prostheses, which could improve the quality of life for numerous patients., This wok was supported by RTI2018-101506-B-C31, RTI2018-101506-B-C32 and RTI2018-101506-B-C33 projects funded by MCIN/AEI/10.13039/501100011033/ from Ministerio de Ciencia, Innovación y Universidades and by “ERDF A way of making Europe”. Grant PRE2019-090122 was funded by MCIN/AEI/10.13039/501100011033/ from Ministerio de Ciencia, Innovación y Universidades and by “ESF Investing in your future”., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Intra-Articular Injection in Wistar Rats: Standardization and Experimental Validation of a Precise Protocol for Nanomaterial Administration

  • Flores-Sáenz, Manuel
  • Chico, Belén
  • García Alonso, María
  • Clemente de Arriba, Celia
  • Aguado-Henche, Soledad
This article belongs to the Special Issue The Future of Nanotechnology: Healthcare and Manufacturing., [Background:] Intra-articular injection is a fundamental technique in preclinical research for evaluating therapeutics and inducing joint disease models in rodents. However, the absence of standardized and validated protocols compromises reproducibility and translational validity., [Methods:] This study establishes and experimentally validates a refined protocol for precise intra-articular injection in the knee of adult male Wistar rats. The comprehensive procedure specifies anatomical landmarks (medial border of the patellar tendon), instrumentation (27 G needle, 100 µL Hamilton syringe), a maximum volume of 35 µL, and operative verification criteria based on tactile feedback. Experimental validation was performed by administering a suspension of wear particles (2.35 mg/mL) generated from tribocorrosion tests of CoCr surfaces biofunctionalized with graphene oxide-hyaluronic acid (GO-HA) into the left knee of five rats., [Results:] Histological analysis using the cutting–grinding technique and Toluidine Blue staining confirmed the exclusive intra-articular localization of particles in all injected animals (5/5 success rate). Qualitative assessment revealed abundant particulate distribution within the synovial space, with numerous individual particles and multiple aggregates observed per high-power field, without evidence of extravasation in any case., [Conclusions:] The protocol demonstrated high intra-operator repeatability and provides a reliable, ethically refined tool for precise intra-articular administration of nanomaterials and for generating robust joint disease models, thereby enhancing reproducibility and animal welfare in preclinical research., This research was funded by the Spanish State Research Agency (Agencia Estatal de Investigación, AEI), grant number RTI2018-101506-B-C32, RTI2018-101506-B-C31. The APC was funded by the Department of Surgery, Medical and Social Sciences, Faculty of Medicine and Health Sciences, University of Alcalá., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Macrophage proteome modulation induced by tribocorrosion of graphene oxide-hyaluronic acid-coated CoCr surfaces

  • Sánchez-López, Luna
  • Chico, Belén
  • García-Alonso, M. C.
  • Lozano, R.M.
Hip and knee implant components, such as femoral bearings, acetabulum liners, and stem taper junctions are subjected to mechanical stresses and undergo electrochemical processes that compromise their functionality. Cobalt-chromium (CoCr) alloys are widely used as implants owing to their excellent mechanical properties, corrosion resistance, and biocompatibility. However, they are susceptible to simultaneous surface processes of wear and corrosion, known as tribocorrosion, which reduce their longevity and impact their performance. Our group has developed covalent multifunctional nanocoatings of graphene oxide (GO) and hyaluronic acid (HA) on CoCr surfaces providing chemical protection, reducing inflammatory response and enhancing wear-corrosion resistance. However, when the GO/HA nanocoating is disrupted by tribocorrosion, as takes place underin vivoconditions, macrophages, crucial cells for inflammation and healing, could exhibit a significantly different proteome. For this purpose, CoCr modified GO/HA surfaces were configured in a tribometer to simulate tribocorrosion of CoCrMo/CoCrMo joint implants, and the biological effects were studied in murine macrophages and analyzed via high-throughput proteomics. Simulated tribocorrosion testing revealed that metal degradation activates phagocytosis and increases endo-lysosomal membrane proteins, indicating enriched phagosomal compartment formation in macrophages. Additionally, macrophage exposure to worn CoCr-modified surfaces activates metal sensitization mechanisms and antigen presentation, leading to macrophage activation and polarization., This work was funded by the Ministerio de Ciencia, Innovación y Universidades (MICIU), Spain, with co-funding from the European Regional Development Fund (FEDER), through grants RTI2018-101506-B-C31 and RTI2018-101506-B-C33. Luna Sánchez-López has received financial support from MICIU for the predoctoral contract (PRE2019-090122)., Peer reviewed
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Hematological Response to Particle Debris Generated During Wear-Corrosion Processes of CoCr Surfaces Modified with Graphene Oxide and Hyaluronic Acid for Joint Prostheses

  • Escudero, María L.
  • García Alonso, María C.
  • Chico, Belén
  • Lozano, Rosa M.
  • Sánchez López, Luna
  • Flores Sáenz, Manuel
  • Cristobal Aguado, Soledad|||0009-0006-5199-9557
  • Moreno Gómez-Toledano, Rafael Felipe|||0000-0002-4834-289X
  • Aguado Henche, Salud Soledad|||0000-0003-2188-3618
Various surface modifications to increase the lifespan of cobalt–chromium (CoCr) joint prostheses are being studied to reduce the wear rate in bone joint applications. One recently proposed modification involves depositing graphene oxide functionalized with hyaluronic acid (a compound present in joints) on CoCr surfaces, which can act as a solid lubricant. This paper analyzes the biological alterations caused by wear–corrosion phenomena that occur in joints, both from the perspective of the worn surface (in vitro model) and the particles generated during the wear processes (in vivo model). The analysis of the inflammatory response of macrophage was performed on CoCr surfaces modified with graphene oxide and functionalized with hyaluronic acid (CoCr-GO-HA), before and after wear–corrosion processes. The wear particles released during the wear–corrosion tests of the CoCr-GO-HA/CoCr ball pair immersed in 3 g/L hyaluronic acid were intra-articularly injected into the experimental animals. The hematological analysis in vivo was made considering a murine model of intra-articular injection into the left knee in male adult Wistar rats, at increasing concentrations of the collected wear particles dispersed in 0.9% NaCl. Non-significant differences in the inflammatory response to unworn CoCr-GO-HA surfaces and control (polystyrene) were obtained. The wear–corrosion of the CoCr-GO-HA disk increased the inflammatory response at both 72 and 96 h of material exposure compared to the unworn CoCr-GO-HA surfaces, although the differences were not statistically significant. The pro-inflammatory response of the macrophages was reduced on the worn surfaces of the CoCr modified and functionalized with graphene oxide (GO) and hyaluronic acid (HA), compared to the worn surfaces of the unmodified CoCr. The hematological analysis and tissue reactions after intra-articular injection did not reveal pathological damage, with average hematological values recorded, although slight reductions in creatinine and protein within non-pathological ranges were found. Some traces of biomaterial particles in the knee at the highest concentration of injected particles were only found but without inflammatory signs. The results show the potential benefits of using graphene in intra-articular prostheses, which could improve the quality of life for numerous patients., Agencia Estatal de Investigación, Ministerio de Ciencia e Innovación