INTERACCION MACROFAGOS-OSTEOBLASTOS-CONDROCITOS EN LA INTERFAZ COCR FUNCIONALIZADO CON OXIDO DE GRAFENO REDUCIDO PARA OPTIMIZACION DE PROTESIS ARTICULARES: EFECTO DEL DESGASTE

RTI2018-101506-B-C33

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 20
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effect of degradation products of iron-bioresorbable implants on the physiological behavior of macrophages in vitro

  • Fagali, Natalia S.
  • Madrid, Marcos A.
  • Pérez-Maceda, B. T.
  • López-Fernández, M.E.
  • Lozano, R.M.
  • Fernández Lorenzo de Mele, Mónica
24 p.-7 fig. (In memory of Dr Blanca Teresa Perez-Maceda whose lovely life, plenty of fortitude, unwavering strength, joy and spiritual values, we had the honour of sharing.), The degradation of bioresorbable metals in vivo changes the physicochemical properties in the environment of an implant, such as a stent in the artery wall, and may induce the alteration of the functions of the surrounding cells. The Fe-degradation, from bioresorbable stents, is a particularly intricate process because it leads to the release of soluble (SDP) and insoluble degradation products(IDP) of varied composition. Macrophages are involved in the resorption of the exogenous agents coming from degradation of these materials. In the present work an Fe0 ring, made with a pure Fe wire,in contact with macrophage cell cultures was used to simulate the behaviour of a biodegradable Fe-based implant in a biological environment. Non-invasive time-lapse optical microscopy was applied to obtain images of macrophages exposed to Fe-degradation products, without using staining to avoid distortions and artefacts. It was noticed that as metal degraded, the IDP formed in situ accumulated close to the Fe0 ring. In this zone, the macrophages showed a dynamic process of uptake of dark Fe-containing products, confirmed by SEM-EDX. These macrophages showed alterations in the morphology and decrease in the motility and viability. The inability of the macrophages to move and to degrade the engulfed products caused a long persistence of IDP in the zone closest to the metal. The deleterious effects of IDP accumulated close to the ring, were significantly worse than those observed in the experiments made with (1) concentrated salt solutions (Fe3+ salt 3 mM), with the same amount of precipitates but uniformly distributed in the well, and (2) diluted salt solutions (Fe3+ salt 1 mM) with mainly soluble species. The results were confirmed by standard staining protocols that revealed dead cells close to the Fe0 ring and oxidative stress in cells exposed to both soluble and insoluble species., CONICET (P-UE 22920170100100CO), ANPCyT (PICT 2015-0232, PICT 2016-1424), UNLP(11/I221), MICINN (MAT2011-29152-C02-02), MINECO (MAT2015-67750-C3-2-R), RTI2018-101506-B-C33., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Corrosion Behaviour and J774A.1 Macrophage Response to Hyaluronic Acid Functionalization of Electrochemically Reduced Graphene Oxide on Biomedical Grade CoCr

  • Chico, Belén
  • Pérez-Maceda, B. T.
  • San José-Pinilla, Sara
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
Improvements in the lubrication of metal¿metal joint prostheses are of great clinical interest in order to minimize the particles released during wear¿corrosion processes. In this work, electrochemically reduced graphene oxide (ErGO) on CoCr was functionalized with hyaluronic acid (ErGOHA). Functionalization was carried out by soaking for 24 h in phosphate buffer saline (PBS) solution containing 3 g/L hyaluronic acid (HA). The corrosion performance of CoCrErGO and CoCrErGOHA surfaces was studied by electrochemical impedance spectroscopy (EIS) for 7 days in PBS. Biocompatibility and cytotoxicity were studied in mouse macrophages J774A.1 cell line by the measurement of mitochondrial activity (WST-1 assay) and plasma membrane damage (LDH assay). The inflammatory response was examined through TNF-¿ and IL-10 cytokines in macrophages culture supernatants, used as indicators of pro-inflammatory and anti-inflammatory responses, respectively. EIS diagrams of CoCrErGOHA revealed two time constants: the first one, attributed to the hydration and diffusion processes of the HA layer adsorbed on ErGO, and the second one, the corrosion resistance of ErGOHA/CoCr interface. Macrophage assays showed better behavior on CoCrErGOHA than CoCr and CoCrErGO surfaces based on their biocompatible, cytotoxic, and inflammatory responses. Comparative analysis of IL-10 showed that functionalization with HA induces higher values of anti-inflammatory cytokine, suggesting an improvement in inflammatory behavior., Financial support received through the RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación y Universidades (MICIU/FEDER), and through the MAT2015-67750-C3-2-R, MAT2015-67750-C3-1-R from the Ministerio de Economía y Competitividad (MINECO/FEDER) from Spain.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Wettability, corrosion resistance, and osteoblast response to reduced graphene oxide on CoCr functionalized with hyaluronic acid

  • Chico, Belén
  • Pérez-Maceda, B. T.
  • San José-Pinilla, Sara
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
14 p.-8 fig.-2 tab. Blanca Teresa Pérez-Maceda who participated actively in this research with great enthusiasm has passed away., The durability of metal–metal prostheses depends on achieving a higher degree of lubrication. The beneficial effect of hyaluronic acid (HA) on the friction and wear of both natural and artificial joints has been reported. For this purpose, graphene oxide layers have been electrochemically reduced on CoCr surfaces (CoCrErGO) and subsequently functionalized with HA (CoCrErGOHA). These layers have been evaluated from the point of view of wettability and corrosion resistance in a physiological medium containing HA. The wettability was analyzed by contact angle measurements in phosphate buffer saline-hyaluronic acid (PBS-HA) solution. The corrosion behavior of functionalized CoCr surfaces was studied with electrochemical measurements. Biocompatibility, cytotoxicity, and expression of proteins related to wound healing and repair were studied in osteoblast-like MC3T3-E1 cell cultures. All of the reported results suggest that HA-functionalized CoCr surfaces, through ErGO layers in HA-containing media, exhibit higher hydrophilicity and better corrosion resistance. Related to this increase in wettability was the increase in the expressions of vimentin and ICAM-1, which favored the growth and adhesion of osteoblasts. Therefore, it is a promising material for consideration in trauma applications, with improved properties in terms of wettability for promoting the adhesion and growth of osteoblasts, which is desirable in implanted materials used for bone repair, Financial support is received through the RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación (MICINN/FEDER), and through the MAT2015-67750-C3-2-R, MAT2015-67750-C3-1-R from the Ministerio de Economía y Competitividad (MINECO/FEDER) from Spain., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Covalent immobilization of graphene oxide on biomedical grade CoCr alloy by an improved multilayer system assembly via Silane/GO bonding

  • Sánchez-López, Luna
  • Chico, Belén
  • Llorente, Irene
  • Escudero Rincón, María Lorenza
  • Lozano, R.M.
  • García-Alonso, M. C.
Improvements in durable lubrication together with minimized wear are essential for obtaining long-term, functioning metallic joint prostheses. To achieve this objective, CoCr surface was functionalized with Graphene Oxide (GO) and characterized by FTIR and XPS. CoCr alloy was subjected to alkalinization in order to generate high hydroxyl content on the surface. FTIR and XPS revealed reactive OH groups, enabling intermediate coupling via (3-aminopropyl) triethoxysilane (APTES), which was cured at 45 °C and 75 °C for 24 h and 30 min, respectively. FTIR revealed cross-linked films (Si–O–Si), inferring condensation and self-assembly of silane layers, while XPS revealed the presence of NH, enabling chemical binding of GO. Silane-coated CoCr disks were immersed in GO solution at 60 °C for 12h and 24h, respectively. FTIR displayed C[dbnd]C band confirming the assembly of GO on silane-coated CoCr surfaces. XPS revealed three possible surface mechanisms: (1) reaction between primary amines of APTES and epoxy groups of GO; (2) free –OH groups in APTES and carboxyl groups in GO; and (3) reaction between APTES primary amines and –OH from carboxyl groups of GO. Overall, the multilayer system CoCr–OH–Si45-GO24h showed covalent functionalization of metal substrate with GO to a large extension of surface area among all the multilayer systems studied., This work was supported through RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerial de Ciencia, Innovación y Universidades (MICIU/FEDER).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Barrier Graphene Oxide on a CoCr Alloy via Silane/GO Covalent Bonding and Its Electrochemical Behavior in a Simulated Synovial Fluid Electrolyte

  • Sánchez-López, Luna
  • Chico, Belén
  • Escudero Rincón, María Lorenza
  • Lozano, R.M.
  • García-Alonso, M. C.
In this work, impermeable and ultrathin surface nanomodifications for joint applications based on graphene oxide (GO) are assembled on CoCr surfaces via covalent immobilization between GO nanosheets and silane monolayers. Two silane curing temperatures, 45 °C for 24 h and 75 °C for 30 min, on CoCr surfaces and two incubation times for GO suspension, 12 h and 24 h, on silanized CoCr surfaces are prepared. Electrochemical characterization is performed using electrochemical impedance spectroscopy (EIS) in a 3 g/L hyaluronic acid solution. Results show that GO nanosheets immobilized with silane covalent bonding confer impermeability of sp2 networks on GO and strong interfacial adhesion of GO sheets anchored to silanized CoCr via organosilane chemistry, which prevents the permeation of oxidant species at the metal interface. At short GO incubation times (12 h), the Rs values decrease with the immersion time, indicating that small species, such as metal ions, are able to diffuse through the interlayer gaps of nanolayers. Longer GO incubation times (24 h) favor the formation of bonds between the GO and the silane, thus slowing downdiffusion and metal ion release into the medium. EIS data confirm the impermeability of GO nanocoatings with lengthening GO incubation time for medical application of metallic implants., Grant RTI2018-101506-B-C31 and RTI2018-101506-B-C33 were funded by Ministerio de Ciencia e Innovación, MCIN/AEI/10.13039/501100011033/, and “ERDF A way of making Europe”. Grant PRE2019-090122 was funded by Ministerio de Ciencia e Innovación, MCIN/AEI/10.13039/501100011033/and “ESF Investing in your future”., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effect of wear-corrosion of reduced graphene oxide functionalized with hyaluronic acid on inflammatory and proteomic response of J774A.1 macrophages

  • Sánchez-López, Luna
  • Ropero de Torres, N.
  • Chico, Belén
  • Fagali, Natalia S.
  • Ríos, Vivian de los
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
The presence of a worn surface in the implanted material, as in the case of a replacement of a damaged osteoarticular joint, is the normal condition after implantation. This manuscript focuses precisely on the comparative study of the cellular behavior on worn CoCr surfaces, analyzing the effect of different surface modifications on macrophages¿ responses. CoCr surfaces were modified by the deposition of electrochemically reduced graphene oxide (CoCrErGO), followed by additional surface functionalization with hyaluronic acid (CoCrErGOHA). After the wear corrosion processes, the macrophage response was studied. In addition, macrophage supernatants exposed to the surfaces, before and after wear, were also evaluated for osteoblast response through the analysis of the metabolic activity, plasma membrane damage, and phosphatase alkaline activity (ALP). The proteomic analysis and the quantitative TNF-¿/IL-10 ratios of the J774A.1 macrophages exposed to the surfaces under study showed a polarization shift from M0 (basal state) to M1, associated with the pro-inflammatory response of all surfaces. A lower M1 polarization was observed upon exposure to the surface modification with ErGO, whereas posterior HA functionalization attenuated, even more, the M1 polarization. The wear corrosion process contributed to inflammation and exacerbated the M1 polarization response on macrophages to CoCr, which was diminished for the ErGO and attenuated the most for the ErGOHA surfaces. Comparative proteomics showed that the pathways related to M1 polarization were downregulated on the surfaces of CoCrErGOHA, which suggests mechanisms for the observed attenuation of M1 polarization. The suitable immuno-modulatory potential induced by the ErGOHA surface, with and without wear, together with the stimulation of ALP activity in osteoblasts induced by macrophage supernatants, promotes the mineralization processes necessary for bone repair. This makes it feasible to consider the adsorption of ErGOHA on CoCr as a recommended surface treatment for the use of biomaterials in osseous joint applications., Financial support was received through the RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación y Universidades (MICIU/FEDER) in Spain. L. Sánchez-López thanks financial support from MICIU for the predoctoral contract PRE2019-090122. ANPCyT (PICT 2019-0631), CONICET (PIP 112-201501-00601CO and External Grant for Young Researchers for N.S.F.) and UNLP (11/X900)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Tribocorrosion behavior of graphene-based solid lubricants biofunctionalized with hyaluronic acid on CoCr surfaces

  • García-Alonso, M. C.
  • Chico, Belén
  • Lozano, R.M.
  • Escudero Rincón, María Lorenza
In this work graphene-based solid lubricants biofunctionalized with hyaluronic acid were deposited on CoCr surfaces to decrease wear-corrosion phenomena. Graphene oxide was electrochemically reduced on CoCr in an aqueous suspension of graphene oxide 4 g/L by cyclic voltammetry. Biofunctionalization in phosphate buffer solution with HA 3 g/L (PBS-HA) for 24 h was performed. A pin-on-disk tribometer with an integrated cell was used for tribocorrosion tests. Wear-corrosion tests were performed against AISI316 steel balls applying normal load 1 N, 120 rpm for 500 m, in PBS and PBS-HA. Coefficients of friction in PBS were higher than in PBS-HA. ErGO and HA-ErGO increased wear rate in AISI316 balls, i.e., ErGO hardens the CoCr surface. Bio- functionalization reduces abrasive properties of ErGO deposits., Funding: This work was supported by the Spanish Ministry of Science, Innovation and Universities [RTI2018–101506-B-C31, RTI2018–101506-B-C33]., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Dataset for the paper "Barrier Graphene Oxide on a CoCr Alloy via Silane/GO Covalent Bonding and Its Electrochemical Behavior in a Simulated Synovial Fluid Electrolyte"

  • Sánchez-López, Luna
  • Chico, Belén
  • Escudero Rincón, María Lorenza
  • Lozano, R.M.
  • García-Alonso, M. C.
[EN] The electrochemical behaviour of each layer deposited on CoCr surfaces was examined by electrochemical impedance spectroscopy (EIS) for 7 days in 3 g/L hyaluronic acid (HA) aqueous solution. Impedance tests were performed in a three-electrode electrochemical cell with the modified CoCr surfaces acting as the working electrode, a Pt wire acting as counter electrode, and Ag/AgCl (3 M KCl) as a reference electrode. The testing area of the working electrode for all electrochemical tests was 0.39 cm2. An Autolab32 potentiostat/galvanostat was used to generate a sinusoidal wave of 10 mV amplitude in the frequency range 100 kHz to 1 mHz, logarithmically spaced by 5 points/decade, which was applied at the corrosion potential Ecorr. Nova software was used for the data acquisition. All the tests were performed in duplicate. The dataset includes only the experimental data used in the paper. The following files for each surface modification and each immersion time are included: CoCr, CoCr-OH, CoCr-OH-Si45, CoCr-OH-Si45-GO12h, CoCr-OH-Si45-GO24h, CoCr-OH-Si75, CoCr-OH-Si75-GO12h, CoCr-OH-Si75-GO24h. Each file is composed of 5 columns: frequency, real impedance (Z'), imaginary impedance (Z''), Impedance modulus (Z) and phase angle (Phase). All files are in open extension such as .txt and are protected by a Creative Commons Attribution 4.0 International (CC BY 4.0) licence. [ES] El comportamiento electroquímico de cada capa depositada en superficies de CoCr fue examinado mediante espectroscopía de impedancia electroquímica (EIS) durante 7 días sumergidas en una solución acuosa de ácido hialurónico (HA) al 3 g/L. Las pruebas de impedancia se realizaron en una celda electroquímica de tres electrodos con las superficies modificadas de CoCr actuando como electrodo de trabajo, un alambre de Pt actuando como electrodo auxiliar y Ag/AgCl (3 M KCl) como electrodo de referencia. El área de ensayo del electrodo de trabajo para todas las pruebas electroquímicas fue de 0.39 cm2. Se utilizó un potenciostato/galvanostato Autolab32 para generar una onda sinusoidal de amplitud de 10 mV en el rango de frecuencia de 100 kHz a 1 mHz, espaciada logarítmicamente por 5 puntos/década, que se aplicó en el potencial de corrosión Ecorr. Se utilizó el software Nova para la adquisición de datos. Todas las pruebas se realizaron por duplicado. El conjunto de datos incluye solo los datos experimentales utilizados en el artículo. Los siguientes archivos para cada modificación de superficie y cada tiempo de inmersión están incluidos: CoCr, CoCr-OH, CoCr-OH-Si45, CoCr-OH-Si45-GO12h, CoCr-OH-Si45-GO24h, CoCr-OH-Si75, CoCr-OH-Si75-GO12h, CoCr-OH-Si75-GO24h. Cada archivo está compuesto por 5 columnas: frecuencia, impedancia real (Z'), impedancia imaginaria (Z''), módulo de impedancia (Z) y ángulo de fase (Fase). Todos los archivos están en extensión abierta como .txt y están protegidos por una licencia Creative Commons Attribution 4.0 International (CC BY 4.0)., [EN] This is the experimental dataset used in the paper “Barrier Graphene Oxide on a CoCr Alloy via Silane/GO Covalent Bonding and Its Electrochemical Behavior in a Simulated Synovial Fluid Electrolyte". The article includes the experimental procedure carried out for the deposition of graphene oxide on CoCr surfaces: CoCr was hydroxylated through alkalization in NaOH 5 M for 2 h, (sample named CoCr-OH). Subsequently, silanization was carried out using APTES. APTES was pre-mixed at 2% vol in isopropanol-water (200:1 v/v) and stirred for 1 h. After this, CoCr-OH samples were immersed in the APTES solution at room temperature for 1 min. The silane-coated samples were kept under curing conditions at 45 °C (CoCr-OH-Si45 sample) and 75 °C (CoCr-OH-Si75 sample) for 24 h and 30 min, respectively. Finally, CoCr-OH-Si45 and CoCr-OH-Si75 surfaces were immersed in 4 g/L GO aqueous suspension at 60 °C for 12 h and 24 h to obtain CoCr-OH-Si45-GO12h, CoCr-OH-Si75-GO12h and CoCr-OH-Si45-GO24h, and CoCr-OH-Si75-GO24h. This data set includes the results of the electrochemical impedance data obtained for each CoCr surface: CoCr (CoCr, CoCr-OH, CoCr-OHSi45, CoCr-OH-Si75 CoCr-OH-Si45-GO12h, CoCr-OH-Si75-GO12h y CoCr-OH-Si45-GO24h, y CoCr-OH-Si75-GO24h, immersed in 3 g/L Hyaluronic acid solution for 7 days., [ES] Este es el conjunto de datos experimentales utilizado en el artículo "Barrera de Óxido de Grafeno en una Aleación CoCr mediante enlace covalente de Silano/GO y su comportamiento electroquímico en un electrolito de fluido sinovial simulado". El artículo incluye el procedimiento experimental llevado a cabo para la deposición de óxido de grafeno sobre superficies de CoCr: CoCr fue hidroxilado mediante alcalinización en NaOH 5 M durante 2 horas (muestra denominada CoCr-OH). Posteriormente, se llevó a cabo la silanización utilizando APTES. APTES fue premezclado al 2% en volumen en isopropanol-agua (200:1 v/v) y agitado durante 1 hora. Después, las muestras de CoCr-OH fueron sumergidas en la solución de APTES a temperatura ambiente durante 1 minuto. Las muestras recubiertas con silano se mantuvieron bajo condiciones de curado a 45 °C (muestra CoCr-OH-Si45) y 75 °C (muestra CoCr-OH-Si75) durante 24 horas y 30 minutos, respectivamente. Finalmente, las superficies CoCr-OH-Si45 y CoCr-OH-Si75 fueron sumergidas en suspensión acuosa de 4 g/L GO a 60 °C durante 12 y 24 horas obteniendo las superficies CoCr-OH-Si45-GO12h, CoCr-OH-Si75-GO12h y CoCr-OH-Si45-GO24h, y CoCr-OH-Si75-GO24h. Este conjunto de datos incluye los resultados de los datos de impedancia electroquímica obtenidos para cada superficie de CoCr (CoCr, CoCr-OH, CoCr-OHSi45, CoCr-OH-Si75 CoCr-OH-Si45-GO12h, CoCr-OH-Si75-GO12h y CoCr-OH-Si45-GO24h, y CoCr-OH-Si75-GO24h sumergidas en una solución de 3 g/L ácido hialurónico durante 7 días., We acknowledge financial support from the Spanish Ministerio de Ciencia, Innovación y Univeesidades, “ERDF A way of making Europe” and “ESF Investing in your future” through projects RTI2018-101506-B-C31 and RTI2018-101506-B-C33, and PRE2019-090122., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Raman and EIS Dataset for the paper "Macrophage Proteomic Analysis of Covalent Immobilization of Hyaluronic Acid and Graphene Oxide on CoCr Alloy in a Tribocorrosive Environment"

  • Sánchez-López, Luna
  • Chico, Belén
  • García-Alonso, M. C.
  • Lozano, R.M.
[EN] CoCrGO and CoCrGOHA surfaces were characterized by Raman spectroscopy and electrochemical impedance spectroscopy (EIS). Raman spectra were collected with a Raman spectrometer B&W TEK (BTC675N) using a 532 nm wavelength laser. Exposure time was set at 100 ms per scan. Spectral data were processed using BWSpec4 software with dark-frame substraction. Spectra were collected from 50 cm-1 to 4000 cm-1 with integration times of 100 s for CoCrGO and CoCrGOH surfaces and 300 s for graphene oxide (GO) reference sample and 20 s for hyaluronic acid (HA) reference sample. EIS data for CoCrGOHA surfaces were recorded up to 23 days of immersion in 3 g/L HA aqueous electrolyte. A three-electrode electrochemical cell consisting of CoCrGO or CoCrGOHA surfaces as working electrodes, a Pt wire as counter electrode and Ag/AgCl (3 M KCl) as reference electrode were used. The testing area of the working electrode for all electrochemical tests was 0.39 cm2. An Autolab32 potentiostat/galvanostat was used to generate a sinusoidal wave of 10 mV amplitude applied at the corrosion potential Ecorr in the 100 kHz- 1 mHz frequency range logarithmically spaced by 5 points/decade. Nova software was used for the data acquisition. All the tests were performed in duplicate. The dataset includes only the experimental data used in the paper. The following folders are included: RamanCoCrGO+CoCrGOHA and EISCoCrGO+CoCrGOHA. Inside Raman spectra folder, Raman files corresponding to CoCrGO and CoCrGOHA surfaces and GO and HA as reference are added. Each Raman file is composed of 8 columns, corresponding to pixel, wavelength, wavenumber, Ramanshift, Reference, Rawdata and Dark substracted. Each file of EIS data is composed of 5 columns: frequency, real impedance (Z’), imaginary impedance (imag Z), Impedance modulus (Z) and phase angle (Phase). All files are in open extension such as .txt and are protected by a Creative Commons Attribution 4.0 International (CC BY 4.0) licence. [ES] Las superficies de CoCrGO y CoCrGOHA fueron caracterizadas mediante espectroscopía Raman y espectroscopía de impedancia electroquímica (EIS). Los espectros Raman fueron recogidos con un espectrómetro Raman B&W TEK (BTC675N) utilizando un láser de longitud de onda de 532 nm. El tiempo de exposición se estableció en 100 ms para cada barrido. Los datos espectrales fueron procesados utilizando el software BWSpec4 con substracción de marco oscuro. Los espectros fueron registrados desde 50 cm-1 hasta 4000 cm-1 con tiempos de integración de 100 s para las superficies de CoCrGO y CoCrGOHA, y de 300 s para la muestra de referencia de GO y de 20 s para la muestra referencia de ácido hialurónico (HA). Los datos de EIS para las superficies CoCrGOHA fueron registrados hasta 23 días de inmersión en electrolito acuoso de 3 g/L HA. Se utilizó una celda electroquímica de tres electrodos consistente en las superficies CoCrGO o CoCrGOHA como electrodos de trabajo, un alambre de Pt como electrodo auxiliar y Ag/AgCl (3 M KCl) como electrodo de referencia. El área de ensayo del electrodo de trabajo para todas las pruebas electroquímicas fue de 0.39 cm2. Se utilizó un potenciostato/galvanostato Autolab32 para generar una onda sinusoidal de amplitud de 10 mV aplicada sobre el potencial de corrosión Ecorr en el rango de frecuencia de 100 kHz a 1 mHz espaciado logarítmicamente 5 puntos/década. Se utilizó el software Nova para la adquisición de datos. Todas las pruebas se realizaron por duplicado. El conjunto de datos incluye únicamente los datos experimentales utilizados en el artículo. Las siguientes carpetas están incluidas: RamanCoCrGO+CoCrGOHA y EISCoCrGO+CoCrGOHA. Dentro de la carpeta de espectros Raman, se agregan archivos Raman correspondientes a las superficies CoCrGO y CoCrGOHA, y las referencias de GO y HA. Dentro de la carpeta de impedancia (EIS) se han añadido los archivos de las superficies de CoCrGO y CoCrGOHA. Cada archivo Raman está compuesto por 8 columnas, correspondientes a píxel, longitud de onda, número de onda, desplazamiento Raman, referencia, datos en crudo y sustracción de fondo. Cada archivo de EIS está compuesto por 5 columnas: frecuencia, impedancia real (Z’), impedancia imaginaria (imag Z), módulo de impedancia (Z) y ángulo de fase (Fase). Todos los archivos están en formato de texto (.txt) y están protegidos por una licencia Creative Commons Attribution 4.0 International (CC BY 4.0)., [EN] This is the experimental dataset used in the paper “Macrophage Proteomic Analysis of Covalent Immobilization of Hyaluronic Acid and Graphene Oxide on CoCr Alloy in a Tribocorrosive Environment". The article includes the experimental procedure carried out for the deposition of graphene oxide and posterior immobilization of hyaluronic acid on CoCr surfaces. CoCr was hydroxylated through alkalization in NaOH 5 M for 2 h. Subsequently, silanization was carried out using APTES. APTES was pre-mixed at 2% vol in isopropanol-water (200:1 v/v) and stirred for 1 h. After this, CoCr-OH samples were immersed in the APTES solution at room temperature for 1 min. The silane-coated samples were kept under curing conditions at 45 °C for 24 h. Then, silanized CoCr surfaces were immersed in 4 g/L GO aqueous suspension at 60 °C for 24 h. Carboxylic groups of graphene oxide in GO/CoCr samples were activated by immersing in distilled water (50 mL) with N-(3-dimethylaminopropyl)-N-ethylcarbodiimide hydrochloride (EDC, 250 mg) and N-hydroxysuccinimide (NHS, 750 mg) during 24 h under mild orbital saking. After that, the GO/CoCr surfaces with activated carboxyl groups were immersed in distilled water (100 mL) with dissolved adipic dihydrazide (ADH, 1.04 g) and let to react for another 24 h under mild orbital shaking. Pre-activated HA-(EDC/NHS) solution was obtained by dissolving HA (100 mg), EDC (253 mg) and NHS (754 mg) in 100 mL phosphate buffer saline (PBS) and stirred for 24h to activate the carboxylic acids of HA. After that, ADH/GO/CoCr surfaces were immersed in pre-activated HA-(EDC/NHS) solution and let to react for 24h under mild orbital motion (samples named HA/GO/CoCr). This data set includes the results of the final surface by Raman Spectroscopy and Electrochemical Impedance Spectroscopy. Raman was obtained from CoCr/GO/HA surfaces in comparison with GO/CoCr surfaces and HA powder. Electrochemical impedance data of CoCr/GO/HA were obtained under immersion in 3 g/L Hyaluronic acid solution up to 23 days., [ES] Este es el conjunto de datos experimentales utilizado en el artículo " Macrophage Proteomic Analysis of Covalent Immobilization of Hyaluronic Acid and Graphene Oxide on CoCr Alloy in a Tribocorrosive Environment". El artículo incluye el procedimiento experimental realizado para la deposición de óxido de grafeno y la posterior inmovilización de ácido hialurónico sobre superficies de CoCr. Las superficies de CoCr fueron hidroxiladas mediante alcalinización en NaOH 5 M durante 2 h. Posteriormente, se realizó la silanización utilizando APTES premezclado al 2% en volumen en isopropanol-agua (200:1 v/v) agitada durante 1 h. Las muestras de CoCr hidroxiladas se sumergieron en la solución de APTES a temperatura ambiente durante 1 minuto. Posteriormente, se mantuvieron en condiciones de curado a 45 °C durante 24 h. Transcurrido este tiempo, las superficies de CoCr silanizadas se sumergieron en una suspensión acuosa de 4g/L GO a 60 °C durante 24 h. Los grupos carboxílicos del óxido de grafeno en las muestras GO/CoCr se activaron mediante inmersión en 50 mL agua destilada que contenía hidrocloruro de N-(3-dimetilaminopropil)-N-etilcarbodiimida (EDC, 250 mg) y N-hidroxisuccinimida (NHS, 750 mg), durante 24 h en agitación orbital suave. Las superficies de GO/CoCr con grupos carboxílicos activados se sumergieron en 100 mL de agua destilada con dihidracida adipídica disuelta (ADH, 1.04 g) y se dejaron reaccionar durante otras 24 h en agitación orbital suave. La solución de HA preactivada (EDC/NHS) se obtuvo disolviendo HA (100 mg), EDC (253 mg) y NHS (754 mg) en 100 mL de solución salina de fosfato (PBS) y agitando durante 24 h para activar los ácidos carboxílicos de la HA. Después, las superficies de ADH/GO/CoCr se sumergieron en la solución de HA preactivada (EDC/NHS) y se dejaron reaccionar durante 24 h en movimiento orbital suave (muestras denominadas HA/GO/CoCr). Este conjunto de datos incluye los resultados de la caracterización superficial final mediante espectroscopía Raman y espectroscopia de impedancia electroquímica. Se obtuvieron espectros Raman de superficies de HA/GO/CoCr, GO/CoCr, y se compararon con GO y ácido hialurónico, utilizados como referencia. Los datos de impedancia electroquímica de CoCr/GO/HA se obtuvieron en inmersión en solución de 3 g/L ácido hialurónico hasta 23 días., We acknowledge financial support from the Ministerio de Ciencia, Innovación y Universidades (MICIN), "ERDF A way of making Europe” and “ESF Investing in your future" through projects RTI2018-101506-B-C31 and RTI2018-101506-B-C31 and the predoctoral grant PRE2019-090122., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Dataset collection of proteomic data for the paper "Effect of wear-corrosion of CoCr functionalized with reduced graphene oxide and hyaluronic acid on the proteomic response of J774A.1 macrophages"

  • Sánchez-López, Luna
  • Ropero de Torres, Noelia
  • Chico, Belén
  • Fagali, Natalia Soledad
  • Ríos, Vivian de los
  • Escudero, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
The presence of a worn surface in the implanted material, as in the case of a replacement of a damaged osteoarticular joint, is the normal condition after implantation. This manuscript focuses precisely on the comparative study of the cellular behavior on worn CoCr surfaces, analyzing the effect of different surface modifications on macrophages’ responses. CoCr surfaces were modified by the deposition of electrochemically reduced graphene oxide (CoCrErGO), followed by additional surface functionalization with hyaluronic acid (CoCrErGOHA). After the wear corrosion processes, the macrophage response was studied. In addition, macrophage supernatants exposed to the surfaces, before and after wear, were also evaluated for osteoblast response through the analysis of the metabolic activity, plasma membrane damage, and phosphatase alkaline activity (ALP). The proteomic analysis and the quantitative TNF- /IL-10 ratios of the J774A.1 macrophages exposed to the surfaces under study showed a polarization shift from M0 (basal state) to M1, associated with the pro-inflammatory response of all surfaces. A lower M1 polarization was observed upon exposure to the surface modification with ErGO, whereas posterior HA functionalization attenuated, even more, the M1 polarization. The wear corrosion process contributed to inflammation and exacerbated the M1 polarization response on macrophages to CoCr, which was diminished for the ErGO and attenuated the most for the ErGOHA surfaces. Comparative proteomics showed that the pathways related to M1 polarization were downregulated on the surfaces of CoCrErGOHA, which suggests mechanisms for the observed attenuation of M1 polarization. The suitable immuno-modulatory potential induced by the ErGOHA surface, with and without wear, together with the stimulation of ALP activity in osteoblasts induced by macrophage supernatants, promotes the mineralization processes necessary for bone repair. This makes it feasible to consider the adsorption of ErGOHA on CoCr as a recommended surface treatment for the use of biomaterials in osseous joint applications., RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación y Universidades (MICIU/FEDER) in Spain. MICIU for the predoctoral contract PRE2019-090122., Proteome Dataset: Effect of wear-corrosion of CoCr functionalized with reduced graphene oxide and hyaluronic acid on the proteomic response of J774A.1 Macrophages, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Macrophage proteomic analysis of covalent immobilization ofhyaluronic acid and graphene oxide on CoCr alloy in atribocorrosive environment

  • Sánchez-López, Luna
  • Chico, Belén
  • García-Alonso, M. C.
  • Lozano, R.M.
19 p.-10 fig.-2 tab., In this work, a sequential covalent immobilization of graphene oxide (GO) and hyaluronic acid (HA) is performed to obtain a biocompatible wear-resistant nanocoating on the surface of the biomedical grade cobalt-chrome (CoCr) alloy. Nanocoated CoCr surfaces were characterized by Raman spectroscopy and electrochemical impedance spectroscopy (EIS) in 3 g/L HA electrolyte. Tribocorrosion tests of the nanocoated CoCr surfaces were carried out in a pin on flat tribometer. The biological response of covalently HA/GO biofunctionalized CoCr surfaces with and without wear-corrosion processes was studied through the analysis of the proteome of macrophages. Raman spectra revealed characteristic bands of GO and HA on the functionalized CoCr surfaces. The electrochemical response by EIS showed a stable and protective behavior over 23 days in the simulated biological environment. HA/GO covalently immobilized on CoCr alloy is able to protect the surface and reduce the wear volume released under tribocorrosion tests. Unsupervised classification analysis of the macrophage proteome via hierarchical clustering and principal component analysis (PCA) revealed that the covalent functionalization on CoCr enhances the macrophage biocompatibility in vitro. On the other hand, disruption of the HA/GO nanocoating by tribocorrosion processes induced a macrophage proteome which was differently clustered and was distantly located in the PCA space. In addition, tribocorrosion induced an increase in the percentage of upregulated and downregulated proteins in the macrophage proteome, revealing that disruption of the covalent nanocoating impacts the macrophage proteome. Although macrophage inflammation induced by tribocorrosion of HA/GO/CoCr surfaces is observed, it is ameliorated by the covalently grafting of HA, which provides immunomodulation by eliciting downregulations in characteristic pro-inflammatory signaling involved in inflammation and aseptic loosening of CoCr joint arthroplasties. Covalent HA/GO nanocoating on CoCr provides potential applications for in vivo joint prostheses led a reduced metal-induced inflammation and degradation by wear-corrosion., This wok was supported by RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación y Universidades (MICIU/FEDER) in Spain. Author L. Sánchez-López has received financial support from MICIU for the predoctoral contract PRE2019-090122, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Dataset for the paper "Hematological response to particle debris generated during wear–corrosion processes of CoCr surfaces modified with gra-phene oxide and hyaluronic acid for joint prostheses"

  • Escudero Rincón, , María Lorenza
  • García-Alonso, M. C.
  • Chico, Belén
  • Lozano, Rosa María
  • Sánchez-López, Luna
  • Flores-Sáenz, Manuel
  • Cristóbal-Aguado, Soledad
  • Moreno-Gómez-Toledano, Rafael
  • Aguado-Henche, Soledad
The dataset includes data on particle characterization of debris collected from wear-corrosion tests and blood analysis from rats after 30 days of inoculation. Particle size distribution of the debris was measured using a MasterSizer 3000 with laser diffraction technology. This device features a red He-Ne laser (wavelength: 632.8 nm), a blue LED laser (wavelength: 470 nm), and a Hydro SV small volume dispersion unit with stirring. Measurements were taken with laser obscuration set between 3% and 15%, and sample dispersion was achieved at 1200 rpm. Two debris samples were analyzed, each with three measurements. The dataset contains six files, each with two columns labeled "size" and "volume."Blood analysis was conducted prior to euthanizing the animals in a CO2 chamber, with 1.5 mL of intracardiac blood extracted. Serum samples were prepared by centrifugation at 3,000 x g for 15 minutes, then separated and stored in 1.5 mL Eppendorf tubes in a cold chamber for transport to a laboratory. Hematological analysis was performed by UNILABS (Madrid, Spain) using a Sysmex Kx-21n hematology autoanalyzer (Sysmex Corporation, Kobe, Japan). The dataset file consists of 21 columns, detailing results by treatment group (Serum control, Hyaluronic acid, and Graphene) and particle concentrations (0.63 mg/ml, 1.83 mg/ml, 1.65 mg/ml, and 2.35 mg/ml). Hematological parameters in the dataset include hemoglobin (Hgb), hematocrit (Hct), white blood cell (WBC) count, red blood cell (RBC) count, mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), and platelet (PLT) count. Biochemical parameters measured in serum samples are creatinine (Crea), aspartate aminotransferase (AST), alanine aminotransferase (ALT), lactate dehydrogenase (LDH), total protein (TP), triglycerides (TG), and cholesterol (CHO). Coagulation parameters include prothrombin time (PT), thromboplastin time (TT), and fibrinogen (F)., [EN] This is the experimental dataset used in the paper "Hematological response to particle debris generated during wear–corrosion processes of CoCr surfaces modified with graphene oxide and hyaluronic acid for joint prostheses". The paper includes the results of the potential biological responses and consequences of wear-corrosion processes associated with CoCr surfaces modified with graphene oxide and hyaluronic acid (CoCr-GO-HA), through in vitro (macrophage cultures) and in vivo (rat models) assays. Once the graphene oxide functionalized with hyaluronic acid was deposited on CoCr surfaces, wear-corrosion tests were performed by applying a 5N load at a rotational speed of 120 rpm over 30,000 m (682,000 cycles) in an aqueous solution of 3 g/L hyaluronic acid (HA), continuously recirculated during the experiment. The generated particles were collected and redispersed in 0.9% NaCl at concentrations of 0.63 mg/mL, 1.65 mg/mL, 1.83 mg/mL, and 2.35 mg/mL. The particles were intra-articularly injected into the knees of rats. This dataset includes the results of the wear particle characterization and the hematological analysis and biochemical parameters, 30 days after intra-articular knee injection in rats. Whole-blood hematological parameters included hemoglobin (Hgb), hematocrit (Hct), white blood cell (WBC) count, red blood cell (RBC) count, mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), and platelet (PLT) count., [ES] Este es el conjunto de datos experimentales utilizado en el artículo "Respuesta hematológica a los desechos de partículas generados durante los procesos de desgaste-corrosión de superficies de CoCr modificadas con óxido de grafeno y ácido hialurónico para prótesis articulares". El artículo incluye los resultados de las posibles respuestas biológicas y consecuencias de los procesos de desgaste-corrosión asociados con superficies de CoCr modificadas con óxido de grafeno y ácido hialurónico (CoCr-GO-HA), mediante ensayos in vitro (cultivos de macrófagos) e in vivo (modelos de ratas). Una vez depositado el óxido de grafeno funcionalizado con ácido hialurónico sobre superficies de CoCr, se realizaron ensayos de desgaste-corrosión aplicando una carga de 5N a una velocidad de rotación de 120 rpm durante 30,000 m (682,000 ciclos) en una solución acuosa 3 g/L de ácido hialurónico (HA), recirculada continuamente durante el experimento. Las partículas generadas se recogieron y se redispersaron en NaCl al 0.9%, a concentraciones de 0.63 mg/mL, 1.65 mg/mL, 1.83 mg/mL y 2.35 mg/mL. Las partículas fueron inyectadas intra-articularmente en rodilla de ratas. Este conjunto de datos incluye los resultados de la caracterización de partículas generadas durante los experimentos de desgaste-corrosión y los análisis hematológicos y parámetros bioquímicos después de 30 días de la inyección intraarticular en las rodillas de las ratas. Los parámetros hematológicos de sangre completa incluyeron hemoglobina (Hgb), hematocrito (Hct), conteo de glóbulos blancos (WBC), conteo de glóbulos rojos (RBC), volumen corpuscular medio (MCV), concentración media de hemoglobina corpuscular (MCHC) y conteo de plaquetas (PLT)., Ministerio de Ciencia e Innovación (MCIN), No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Hematological Response to Particle Debris Generated During Wear–Corrosion Processes of CoCr Surfaces Modified with Graphene Oxide and Hyaluronic Acid for Joint Prostheses

  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Chico, Belén
  • Lozano, R.M.
  • Sánchez-López, Luna
  • Flores-Sáenz, Manuel
  • Cristóbal-Aguado, Soledad
  • Moreno-Gómez-Toledano, Rafael
  • Aguado-Henche, Soledad
Various surface modifications to increase the lifespan of cobalt–chromium (CoCr) joint prostheses are being studied to reduce the wear rate in bone joint applications. One recently proposed modification involves depositing graphene oxide functionalized with hyaluronic acid (a compound present in joints) on CoCr surfaces, which can act as a solid lubricant. This paper analyzes the biological alterations caused by wear–corrosion phenomena that occur in joints, both from the perspective of the worn surface (in vitro model) and the particles generated during the wear processes (in vivo model). The analysis of the inflammatory response of macrophage was performed on CoCr surfaces modified with graphene oxide and functionalized with hyaluronic acid (CoCr-GO-HA), before and after wear–corrosion processes. The wear particles released during the wear–corrosion tests of the CoCr-GO-HA/CoCr ball pair immersed in 3 g/L hyaluronic acid were intra-articularly injected into the experimental animals. The hematological analysis in vivo was made considering a murine model of intra-articular injection into the left knee in male adult Wistar rats, at increasing concentrations of the collected wear particles dispersed in 0.9% NaCl. Non-significant differences in the inflammatory response to unworn CoCr-GO-HA surfaces and control (polystyrene) were obtained. The wear–corrosion of the CoCr-GO-HA disk increased the inflammatory response at both 72 and 96 h of material exposure compared to the unworn CoCr-GO-HA surfaces, although the differences were not statistically significant. The pro-inflammatory response of the macrophages was reduced on the worn surfaces of the CoCr modified and functionalized with graphene oxide (GO) and hyaluronic acid (HA), compared to the worn surfaces of the unmodified CoCr. The hematological analysis and tissue reactions after intra-articular injection did not reveal pathological damage, with average hematological values recorded, although slight reductions in creatinine and protein within non-pathological ranges were found. Some traces of biomaterial particles in the knee at the highest concentration of injected particles were only found but without inflammatory signs. The results show the potential benefits of using graphene in intra-articular prostheses, which could improve the quality of life for numerous patients., This wok was supported by RTI2018-101506-B-C31, RTI2018-101506-B-C32 and RTI2018-101506-B-C33 projects funded by MCIN/AEI/10.13039/501100011033/ from Ministerio de Ciencia, Innovación y Universidades and by “ERDF A way of making Europe”. Grant PRE2019-090122 was funded by MCIN/AEI/10.13039/501100011033/ from Ministerio de Ciencia, Innovación y Universidades and by “ESF Investing in your future”., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

The Potential Application of AZ31-Mg(OH)2/CeO2 as Temporary Medical Implants: Evaluation of the Corrosion Resistance and Biocompatibility Properties

  • Onofre-Bustamante, E.
  • Lozano, R.M.
  • Escudero Rincón, María Lorenza
  • Spíndola-Flores, Ana
  • Benito-Santiago, Sandra
Magnesium-based alloys are considered to be promising materials for the fabrication of temporary bone repair medical implants. The AZ31 magnesium-based (AZ31-Mg) alloy contains 3% aluminum and 1% zinc in its microstructure, which gives it mechanical strength and corrosion resistance. Nonetheless, the corrosion rate is high, which can lead to implant failure due to rapid degradation, which triggers the release of harmful metal ions. In the present work, a passive layer was obtained on the AZ31-Mg alloy, and subsequently, a cerium oxide (CeO2) coating was deposited through a chemical conversion treatment using 0.01 M CeO2 as a precursor. Based on X-ray photoelectron spectroscopy, the calculated amount of Ce(IV) and Ce(III) present in AZ31-Mg(OH)2/CeO2 was 93.6% and 6.4%, respectively. AZ31-Mg(OH)2/CeO2 showed improved corrosion resistance compared with the bare sample. The in vitro assessment of MC3T3-E1 pre-osteoblast cell viability showed that AZ31-Mg(OH)2/CeO2 was biocompatible after incubation for 24 and 72 h. The results revealed that the CeO2 coating confers greater electrochemical stability and biocompatibility properties, mostly due to the presence of Ce4+ ions., This research was supported by Secretaría de Ciencia, Humanindades, Tecnología e Innovación (SECIHTI) Science grant, (SIP project 20253511 and 20250589) through Instituto Politécnico Nacional. Financial support was also obtained from ICOOP 2021 (Ref COOPA20479) of Consejo Superior de Investigaciones Científicas (CSIC, Spain) and by RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación y Universidades (MICIU/FEDER) in Spain., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Tesis doctoral (DoctoralThesis)

Design and Characterization of Graphene multilayer systems on biomedical grade CoCr alloy. Tribocorrosion performance and study of cellular and inflammatory responses induced by tribological processes, Diseño y caracterización de sistemas multicapa de base grafeno sobre aleación de CoCr de grado biomédico. Comportamiento a tribocorrosión y estudio de la respuesta celular e inflamatoria inducidas por procesos tribológicos

  • Sánchez-López, Luna
Tesis Doctoral inédita leída en la Universidad Autónoma de Madrid, Facultad de Medicina, Departamento de Física Aplicada--Programa de Doctorado en Materiales Avanzados y Nanotecnología--169 pag, [EN] Implant bearings are degraded chemically and mechanically where metal-on-ceramic and metal on UHMWPE bearings provide the best tribology performance in implants with low coefficients of friction up to 0.002-0.007 for metal-on-ceramic and 0.06-0.08 for Metal on UHMWPE; translating into lowest wear rates in these types of implants. Decreasing the degradation rates of these implants can prolong the operating functional time of implants and the wellbeing of patients since high wear rates trigger failure of implants, and osteolysis and adverse reactions induced by wear particles. Improvements in biomedical alloys associated with high corrosion resistance, reduced passive dissolution, increased wear resistance and reduced wear-accelerated corrosion can result in improved material qualities of the implants. Metal surface modifications with graphene-based materials have the potential to reduce implant degradation rates. The adhesion strength on the metal and the type of bonding interaction is of great importance to provide desired properties, where the reduction of corrosion depends on the adhesion strength of graphene monolayers adsorbed on metal surfaces. In Publication I the strength adhesion of graphene oxide on CoCr is promoted by covalent binding and characterized by XPS and FTIR by silanization and reaction layer-by-layer system assembly. In Publication II the corrosion evaluation of CoCr alloy with the covalent modification is characterized by EIS. Covalent bonding of a biomolecule high weight hyaluronic acid (HMW-HA) was applied for biofunctionalization of the biomaterials and to provide immunomodulation. In Publication III CoCrMo with covalent bonding of this biomolecule and covalent bonding of graphene oxide is characterized in terms of corrosion resistance and biocompatibility. In Publication III and IV, the tribology behavior of CoCrMo with the graphene-based films is characterized by profilometry and tribometer tests showing to reduce abrasive wear in tribopairs of the implants. Accelerated degradation of these implants and the concerns in the biological effects should also be evaluated. In Publication IV tribological tests were performed to mimic accelerated degradation of the prosthesis. The response of macrophage and osteoblast cell lines due to accelerated degradation of the implant was studied by analysis of the macrophage proteome expression and cytokine markers., [ES] Los rodamientos formados en implantes biomédicos se degradan química y mecánicamente; en los cuales el rodamient formado por metal-cerámica y metal-UHMWPE proporcionan el mejor rendimiento tribológico en implantes con bajos coeficientes de fricción de 0,002 y 0,06 respectivamente, lo que se traduce en tasas de desgaste bajas en este tipo de implantes. La disminución de las tasas de degradación de estos implantes puede prolongar el tiempo operativo de los implantes y el bienestar de los pacientes ya que las altas tasas de desgaste provocan fallas de los implantes al igual que osteólisis y reacciones adversas inducidas por las partículas de desgaste. Mejoras asociadas a una alta resistencia a la corrosión, una disolución pasiva reducida, una mayor resistencia mecánica al desgaste y una reducción de la corrosión acelerada por desgaste pueden traducirse en la mejora de propiedades de los biomateriales metálicos. Las modificaciones superficiales metálicas con materiales de grafeno tienen el potencial de reducir las tasas de degradación de los implantes. La fuerza de adhesión sobre el metal y el tipo de interacción de unión es de gran importancia para proporcionar las propiedades deseadas, donde la reducción de la corrosión depende de la fuerza de adhesión de las monocapas de grafeno adsorbidas sobre las superficies metálicas. En la Publicación I, la fuerza de adhesión del óxido de grafeno sobre CoCr se promueve mediante unión covalente y se caracteriza por XPS y FTIR mediante silanización y ensamblaje del sistema de reacción entre láminas. En la Publicación II, la evaluación de la corrosión de la aleación de CoCr con la modificación covalente se caracteriza mediante EIS. Se aplicó el enlace covalente de una biomolécula de ácido hialurónico de alto peso (HMW-HA) para biofuncionalizar los biomateriales y proporcionar inmunomodulación. En la Publicación III, se caracteriza el CoCrMo con enlace covalente de esta biomolécula y enlace covalente de óxido de grafeno, en términos de resistencia a la corrosión y biocompatibilidad. En las publicaciones III y IV, el comportamiento tribológico de CoCrMo con covalentemente adherido al grafeno se caracteriza mediante pruebas de perfilometría y tribología que muestran una reducción del desgaste abrasivo en tribopares de implantes. La degradación acelerada de estos implantes y sus efectos biológicos se evalúan en la Publicación IV mediante pruebas tribológicas que provocan la degradación acelerada de la prótesis. La respuesta de líneas celulares de macrófagos y osteoblastos debido a la degradación acelerada del implante se estudió mediante el análisis de la expresión del proteoma de macrófagos y marcadores de citoquinas, La realización de este trabajo ha sido financiad0 por los proyectos RTI2018-101506-B-C31 y RTI2018-101506-B-C33 (CIB-MS) del Ministerio de Ciencia Innovación y Universidades (MICIU/FEDER). Laura Sánchez ha sido perceptora de la ayuda PRE2019-090122 para su contratación predoctoral, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Past, Present, and Future of Fe-Mg Bioresorbable Alloys for Medical Applications

  • Estrada, Rafael Guillermo
  • Fagali, Natalia S.
  • Multigner, Marta
  • Lieblich, Marcela
The search for biocompatible and bioabsorbable metallic materials for temporary medical implants dates back to the late nineteenth century. Interest in these materials arises from their potential social and medical benefits. However, extensive research did not start until the early twentieth century, primarily focusing on magnesium (Mg), iron (Fe), and zinc (Zn) as biocompatible and biodegradable base metals. In this work, we explore the combination of two of these metals, Fe and Mg, and the opportunity to investigate Fe-Mg alloys as potential candidates for biomedical applications through a review of their development from their initial production to the present, as well as their future prospects. A distinctive characteristic of Fe-Mg systems is their mutual immiscibility in thermodynamic equilibrium, which poses significant processing challenges and explains why Fe-Mg alloys have been relatively unexplored. However, it is precisely this immiscibility that offers the opportunity to achieve a metastable state that potentiates degradation. As evidenced by the review of recent research on bioabsorbable Fe-Mg alloys developed specifically for biomedical applications, given their promising properties and potential applications, a more comprehensive exploration of this alloy system appears warranted., Grant PID2022-139323NB-I00, PRE2020-092118 (R.E.), PID2021-123891OB-I00 funded by MCIN/AEI/ https://doi.org/10.13039/501100011033, RTI2018-101506-B-C33 by MICIU/FEDER Spain. CONICET [PIP 2021 11220200100315CO]; ANPCyT [PICT 2019-00631, PICT-2020-02169, PICT Start Up 2020-0034]; and UNLP [Project 11/X900].
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Past, Present, and Future of Fe-Mg Bioresorbable Alloys for Medical Applications

  • Estrada, Rafael Guillermo
  • Fagali, Natalia S.
  • Multigner, Marta
  • Lieblich, Marcela
The search for biocompatible and bioabsorbable metallic materials for temporary medical implants dates back to the late nineteenth century. Interest in these materials arises from their potential social and medical benefits. However, extensive research did not start until the early twentieth century, primarily focusing on magnesium (Mg), iron (Fe), and zinc (Zn) as biocompatible and biodegradable base metals. In this work, we explore the combination of two of these metals, Fe and Mg, and the opportunity to investigate Fe-Mg alloys as potential candidates for biomedical applications through a review of their development from their initial production to the present, as well as their future prospects. A distinctive characteristic of Fe-Mg systems is their mutual immiscibility in thermodynamic equilibrium, which poses significant processing challenges and explains why Fe-Mg alloys have been relatively unexplored. However, it is precisely this immiscibility that offers the opportunity to achieve a metastable state that potentiates degradation. As evidenced by the review of recent research on bioabsorbable Fe-Mg alloys developed specifically for biomedical applications, given their promising properties and potential applications, a more comprehensive exploration of this alloy system appears warranted., Grant PID2022-139323NB-I00, PRE2020-092118 (R.E.), PID2021-123891OB-I00 funded by MCIN/AEI/ https://doi.org/10.13039/501100011033, RTI2018-101506-B-C33 by MICIU/FEDER Spain. CONICET [PIP 2021 11220200100315CO]; ANPCyT [PICT 2019-00631, PICT-2020-02169, PICT Start Up 2020-0034]; and UNLP [Project 11/X900].
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Degradation, cytotoxicity, and antibacterial properties of Fe-Mg powders in simulated body fluids

  • Estrada, Rafael Guillermo
  • Fagali, Natalia Soledad
  • Multigner, Marta
  • Lozano, R.M.
  • Pacha-Olivenza, Miguel
  • González-Martín, María Luisa
  • Lieblich, Marcela
Bioabsorbable metals offer great promise for temporary medical implants. Among them, iron (Fe) and magnesium (Mg) alloys are of particular interest due to their biocompatibility, mechanical properties, and degradation behavior. However, Fe degrades too slowly, while Mg degrades too quickly. Combining both elements has been proposed to overcome these drawbacks, though their immiscibility presents a processing challenge. In this study, Fe-5 wt% Mg powder was produced via high-energy ball milling (Fe5Mg-BM), and its degradation was compared with pure Fe (Fe99) and milled Fe (Fe-BM). In vitro degradation was evaluated in three simulated body fluids: phosphate-buffered saline (PBS), modified Hanks' balanced salt solution (HBSS), and Dulbecco's Modified Eagle Medium (DMEM). Ion release, pH changes, and degradation products were characterized, along with cytotoxicity and antibacterial activity. The results showed that Fe5Mg-BM exhibited accelerated degradation compared to Fe99 and Fe-BM. Among the media, modified HBSS induced the greatest diversity and quantity of degraded compounds. Ion analysis revealed negligible iron release in PBS and HBSS, with the highest levels in DMEM for Fe5Mg-BM. Magnesium release followed the trend: PBS < DMEM < HBSS. Fe5Mg-BM showed limited cytotoxicity at 3 days and enhanced antibacterial activity in PBS and HBSS compared to Fe-BM. These results indicate that the biological effects arise from complex interactions at the material interface and the solubility of degradation products, suggesting that Mg is a promising alloying element for enhancing the performance of Fe-based materials in biomedical applications., Grant PID2022–139323NB-I00, PRE2020–092118 (R.E.), PID2022–140422OB-I00, PID2021–123891OB-I00 funded by MCIN/AEI/ 10.13039/501100011033, Spain. Thanks are due to the Laboratory of x-ray diffraction and of Electron Microscopy of CENIM-CSIC. RTI2018–101506-B-C33 by MICIU/FEDER and FEDER “Una manera de hacer Europa”; GR24043 supported by Government of Extremadura, Project Action VI by UEX. Microbiology measurements were performed by the ICTS “NANBIOSIS,” specifically by the U16 Unit: “Surface Characterization and Bacterial Colonization” of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) located at the University of Extremadura in Badajoz (Spain). CONICET (External Fellowship of NSF, PIP 2021 11220200100315CO), ANPCyT (PICT 2019–0631, PICT Start Up 2020–0034, PICT 2020–02169), UNLP (11/X900)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Macrophage proteome modulation induced by tribocorrosion of graphene oxide-hyaluronic acid-coated CoCr surfaces

  • Sánchez-López, Luna
  • Chico, Belén
  • García-Alonso, M. C.
  • Lozano, R.M.
Hip and knee implant components, such as femoral bearings, acetabulum liners, and stem taper junctions are subjected to mechanical stresses and undergo electrochemical processes that compromise their functionality. Cobalt-chromium (CoCr) alloys are widely used as implants owing to their excellent mechanical properties, corrosion resistance, and biocompatibility. However, they are susceptible to simultaneous surface processes of wear and corrosion, known as tribocorrosion, which reduce their longevity and impact their performance. Our group has developed covalent multifunctional nanocoatings of graphene oxide (GO) and hyaluronic acid (HA) on CoCr surfaces providing chemical protection, reducing inflammatory response and enhancing wear-corrosion resistance. However, when the GO/HA nanocoating is disrupted by tribocorrosion, as takes place underin vivoconditions, macrophages, crucial cells for inflammation and healing, could exhibit a significantly different proteome. For this purpose, CoCr modified GO/HA surfaces were configured in a tribometer to simulate tribocorrosion of CoCrMo/CoCrMo joint implants, and the biological effects were studied in murine macrophages and analyzed via high-throughput proteomics. Simulated tribocorrosion testing revealed that metal degradation activates phagocytosis and increases endo-lysosomal membrane proteins, indicating enriched phagosomal compartment formation in macrophages. Additionally, macrophage exposure to worn CoCr-modified surfaces activates metal sensitization mechanisms and antigen presentation, leading to macrophage activation and polarization., This work was funded by the Ministerio de Ciencia, Innovación y Universidades (MICIU), Spain, with co-funding from the European Regional Development Fund (FEDER), through grants RTI2018-101506-B-C31 and RTI2018-101506-B-C33. Luna Sánchez-López has received financial support from MICIU for the predoctoral contract (PRE2019-090122)., Peer reviewed
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Hematological Response to Particle Debris Generated During Wear-Corrosion Processes of CoCr Surfaces Modified with Graphene Oxide and Hyaluronic Acid for Joint Prostheses

  • Escudero, María L.
  • García Alonso, María C.
  • Chico, Belén
  • Lozano, Rosa M.
  • Sánchez López, Luna
  • Flores Sáenz, Manuel
  • Cristobal Aguado, Soledad|||0009-0006-5199-9557
  • Moreno Gómez-Toledano, Rafael Felipe|||0000-0002-4834-289X
  • Aguado Henche, Salud Soledad|||0000-0003-2188-3618
Various surface modifications to increase the lifespan of cobalt–chromium (CoCr) joint prostheses are being studied to reduce the wear rate in bone joint applications. One recently proposed modification involves depositing graphene oxide functionalized with hyaluronic acid (a compound present in joints) on CoCr surfaces, which can act as a solid lubricant. This paper analyzes the biological alterations caused by wear–corrosion phenomena that occur in joints, both from the perspective of the worn surface (in vitro model) and the particles generated during the wear processes (in vivo model). The analysis of the inflammatory response of macrophage was performed on CoCr surfaces modified with graphene oxide and functionalized with hyaluronic acid (CoCr-GO-HA), before and after wear–corrosion processes. The wear particles released during the wear–corrosion tests of the CoCr-GO-HA/CoCr ball pair immersed in 3 g/L hyaluronic acid were intra-articularly injected into the experimental animals. The hematological analysis in vivo was made considering a murine model of intra-articular injection into the left knee in male adult Wistar rats, at increasing concentrations of the collected wear particles dispersed in 0.9% NaCl. Non-significant differences in the inflammatory response to unworn CoCr-GO-HA surfaces and control (polystyrene) were obtained. The wear–corrosion of the CoCr-GO-HA disk increased the inflammatory response at both 72 and 96 h of material exposure compared to the unworn CoCr-GO-HA surfaces, although the differences were not statistically significant. The pro-inflammatory response of the macrophages was reduced on the worn surfaces of the CoCr modified and functionalized with graphene oxide (GO) and hyaluronic acid (HA), compared to the worn surfaces of the unmodified CoCr. The hematological analysis and tissue reactions after intra-articular injection did not reveal pathological damage, with average hematological values recorded, although slight reductions in creatinine and protein within non-pathological ranges were found. Some traces of biomaterial particles in the knee at the highest concentration of injected particles were only found but without inflammatory signs. The results show the potential benefits of using graphene in intra-articular prostheses, which could improve the quality of life for numerous patients., Agencia Estatal de Investigación, Ministerio de Ciencia e Innovación