Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 54
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Actuator-fault detection and isolation based on interval observers and invariant sets

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
Trabajo presentado a la 52nd CDC celebrada en Florencia del 10 al 13 de diciembre de 2013., This paper proposes an interval observer-based actuator fault detection and isolation (FDI) approach. An interval observer matching the healthy system mode is designed to monitor the system. When the system is in different modes, state or output interval vectors predicted by the interval observer manifest different dynamical behaviors. To guarantee reliable FDI, a collection of invariant set-based FDI conditions are established. Under these conditions, actuator faults can be accurately detected and isolated during the transition between different modes. At the end, the effectiveness of this proposed approach is presented by using a numerical example., The work of F. Xu, V. Puig and C. Ocampo-Martinez has been supported by Spanish research project WATMAN (DPI2009-13744) of the Science and Technology Ministry, by the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), by European Comission through contract i-Sense (FP7-ICT-2009-6-270428), and by China Scholarship Council (File No.2011629170). Besi, Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

A service reliability model predictive control with dynamic safety stocks and actuators health monitoring for drinking water networks

  • Grosso, J. M.
  • Ocampo-Martínez, Carlos
  • Puig, Vicenç
Trabajo presentado al 51st CDC celebrado en Maui (Hawai) del 10 al 13 de diciembre de 2012., This paper presents a model predictive control strategy to assure reliability in drinking water networks given a customer service level and a forecasting demand. The underlying idea concerns a two-layer hierarchical control structure. The upper layer performs a local steady-state optimization to set up an inventory replenishment policy based on dynamic safety stocks for each tank in the network. At the same stage, actuators health is revised to set up their next maximum allowable degradation in order to efficiently distribute overall control effort and guarantee system availability. In the lower layer, a model predictive control algorithm is implemented to compute optimal control set-points to minimize a multiobjective cost function. Simulation results in the Barcelona Drinking Water Network have shown the effectiveness of the dynamic safety stocks allocation and the actuators health monitoring to assure service reliability and optimizing network operational costs., This work has been supported by Spanish research projects WATMAN (CICYT DPI2009-13744) and SHERECS (CYCYT DPI2011-26243) of the Science and Technology Ministry, the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), and by European Comission through contract i-Sense (FP7-ICT-2009-6-270428), Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Model-based optimal sensor placement approaches to fuel cell stack system fault diagnosis

  • Sarrate, Ramon
  • Nejjari, Fatiha
  • Rosich, Albert
Trabajo presentado al 8th IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes celebrado en México del 29 al 31 de agosto de 2012., The problem of optimal sensor placement for FDI consists in determining the set of sensors that minimizes a pre-defined cost function satisfying at the same time a pre-established set of FDI specifications for a given set of faults. This paper recalls three model-based optimal sensor location approaches: an Incremental search, a Heuristic search and a Binary Integer Linear Programming (BILP) formulation. The main contribution of this paper is a comparative study that addresses efficiency, flexibility and other issues. The performance of the approaches is demonstrated by an application to a fuel cell stack system., This work has been funded by the Spanish Ministry of Science and Technology through the CICYT project WATMAN (ref. DPI2009-13744), by the Spanish Ministry of Economy and Competitiveness through the CICYT project SHERECS (ref. DPI2011-26243), and by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault detection and isolation based on structural models

  • Rosich, Albert
Trabajo presentado al 8th IFAC Symposium on SAFEPROCESS celebrado en Mexico del 29 al 31 de agosto de 2012., This paper presents a new algorithm for solving the sensor placement problem in order to achieve the required fault detectability and isolability. The method is based on structural models, which means that non-linear differential systems can be efficiently handled. The developed algorithm does not need to compute any residual since it is based on structural model properties. Thus, the residual computation burden is avoided. The method can also handle faults of the extra placed sensors as well as the possibility of installing repeated sensors., This work has been funded by the Spanish Ministry of Science and Technology through the CICYT project WATMAN (ref. DPI2009-13744), and by the European Commission through contract i-Sense (ref. FP7-ICT-2009- 6-270428)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Fault detection and isolation based on the combination of a bank of interval observers and invariant sets

  • Xu, Feng
  • Stoican, Florin
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
Presentado al 21st MED celebrado en Chania (Grecia) del 25 al 28 de junio de 2013., In this paper, a fault detection and isolation (FDI) approach using a bank of interval observers is developed. From the methodological point of view, a bank of interval observers is designed from different dynamical models of the system under healthy and faulty situations. Each dedicated interval observer matches one possible situation while all designed interval observers monitor the system simultaneously and independently. For the sake of guaranteed FDI, a set of FDI sufficient conditions are established based on invariant set notions. These conditions ensure that the faults can be accurately isolated after sufficiently long monitoring time. Finally, simulation results over a subsystem of a wind turbine are used to present the effectiveness of the proposed approach., The work of F. Xu, V. Puig and C. Ocampo-Martinez has been supported by the Spanish research project WATMAN (CICYT DPI2009-13744) of the Science and Technology Ministry and by the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), and by European Comission through contract i-Sense (FP7-ICT-2009-6-270428). F. Xu is also supported by the China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

On the relationship between interval observers and invariant sets in fault detection

  • Xu, Feng
  • Stoican, Florin
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
Presentado al SysTol 2013 celebrado en Niza del 9 al 11 de octubre., In this paper, the relationship between two set theoretic fault detection (FD) approaches, the interval observer based and the invariant set-based approaches, is investigated. In FD, interval observers monitor the system dynamic behavior in real time and generates adaptive intervals for system outputs. Invariant sets focus more on steady state behavior of the system rather than the transient behavior. This paper discusses these two approaches, presents the relationship between them and compares them in the FD task. At the end, a numerical example is used to illustrate the relation between these two approaches., The work of F. Xu, V. Puig and C. Ocampo-Martinez has been supported by Spanish research projects WAT-MAN (CICYT DPI2009-13744) and CICYT SHERECS DPI-2011-26243 of the Science and Technology Ministry, by the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), by European Comission through contract i-Sense (FP7-ICT-2009-6-270428), and by China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault detection and isolation using Interval observers

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
Presentado al SysTol 2013 celebrado en Niza del 9 al 11 de octubre., This paper proposes an interval observer-based sensor fault detection and isolation (FDI) approach for the closed-loop systems. In this proposed approach, residuals are defined in such a way that their components are independent of each other at the time instant after fault occurrence, namely kf + 1, where kf denotes the fault occurrence time instant. In this way, it is guaranteed that at kf + 1 the changes in each component of the residuals are only related to the fault in the corresponding sensor. By detecting the threshold violation of the corresponding residual interval components, the proposed method can detect and isolate sensor faults at that time instant. At the end of this paper, a numerical example is used to present the effectiveness of the approach., The work of F. Xu, V. Puig and C. Ocampo-Martinez has been supported by Spanish research project WATMAN (CICYT DPI2009-13744) of the Science and Technology Ministry, by the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), by European Comission through contract i-Sense (FP7-ICT-2009-6-270428), and by China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization under budgetary constraints

  • Sarrate, Ramon
  • Nejjari, Fatiha
  • Rosich, Albert
Presentado al 2nd International Conference on Systems and Control celebrado en Marruecos del 20 al 22 de junio de 2012., This paper presents a strategy based on fault diagnosability maximization to optimally locate sensors in complex systems. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of diagnosability and does not exceed a maximum sensor configuration cost. The strategy is based on the structural system model. Structural analysis is a powerful tool for dealing with complex nonlinear systems. The proposed approach is successfully applied to a Fuel Cell Stack System., This work has been funded by the Spanish Ministry of Science and Technology through the following projects CICYT WATMAN DPI2009-13744 and CICYT SHERECS DPI2011- 26243 and by European Comission through contract i-Sense FP7-ICT-2009- 6-270428., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Methodology for actuator fault tolerance evaluation of linear constrained MPC: Application to the Barcelona water network

  • Robles, Deneb
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Garza-Castañón, Luis E.
Presentado al 20th MED celebrado en Barcelona del 3 al 6 de julio de 2012., This paper presents a methodology to evaluate the admissibility of actuator fault configurations (AFC) when Linear Constrained Model Predictive Control (LCMPC) is used. The methodology combines the use of structural and feasability analysis. Structural analysis allows to evaluate the loss of reachability after a fault occurrence. The results of the structural analysis can be complemented with the feasibility analysis of the MPC problem taking into account the effect of actuator constraints after the fault occurrence. Additionally, a degradation analysis of the system performance can also be included. The proposed methodology is tested in the Barcelona water network., This work has been partially funded by the Spanish Ministry of Science and Technology through the following project SHERECS (Ref. DPI2011-26243), WATMAN (Ref. DPI2009-13744), and by European Comission through contract i-Sense (Ref. FP7-ICT-2009-6-270428)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization in distribution networks

  • Sarrate, Ramon
  • Nejjari, Fatiha
  • Rosich, Albert
20th Mediterranean Conference on Control & Automation: 518-523 (2012), The success of any diagnosis strategy critically depends on the sensors measuring process variables. This paper presents a strategy based on diagnosability maximization for optimally locating sensors in distribution networks. The goal is to characterize and determine the set of sensors that guarantees a maximum degree of diagnosability taking into account a given sensor configuration cardinality constraint. The strategy is based on the structural model of the system under consideration. Structural analysis is a powerful tool for determining diagnosis possibilities and evaluating whether the number and the location of sensors are adequate in order to meet some diagnosis specifications. The proposed approach is successfully applied to leakage detection in a Drinking Water Distribution Network., This work has been funded by the Spanish Ministry of Science and Technology through the CICYT project WATMAN (ref. DPI2009-13744), by the Spanish Ministry of Economy and Competitiveness through the CICYT projecte SHERECS (ref. DPI2011-26243), and by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Fault diagnosis of a wind farm using interval parity equations

  • Blesa, Joaquim
  • Jiménez, Pedro
  • Rotondo, Damiano
  • Nejjari, Fatiha
  • Puig, Vicenç
Trabajo presentado al 19th IFAC World Congress celebrado del 24 al 29 de agosto de 2014 en Cape Town (Sudafrica)., In this paper, the problem of fault diagnosis of a wind farm is addressed using interval parity equations. Fault detection is based on the use of parity equations and unknown but bounded description of the noise and modeling errors. The fault detection test is based on checking the consistency between the measurements and the model by finding if the formers are inside the interval prediction bounds. The fault isolation algorithm is based on analyzing the observed fault signatures on-line, and matching them with the theoretical ones obtained using structural analysis. Finally, the proposed approach is tested using the wind farm benchmark proposed in the context of the wind farm FDI/FTC competition., This work has been funded by the Spanish MINECO through the project CYCYT SHERECS (ref. DPI2011-26243), by the European Commission through contract i-Sense (ref. FP7-ICT-2009-6-270428) and by AGAUR through the contract FI-DGR 2013 (ref. 2013FIB00218)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Improved actuator-fault detection and isolation strategy using interval observers and invariant sets

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
Trabajo presentado al 19th IFAC World Congress celebrado del 24 al 29 de agosto de 2014 en Cape Town (Sudafrica)., In this paper, an improved algorithm for an actuator fault detection and isolation (FDI) framework using a bank of interval observers previously proposed by the authors is presented, where each interval observer matches one possible system mode. Under a set of FDI conditions, this new algorithm can accurately detect and isolate the considered actuator faults. The advantage of this new algorithm consists in that it extends the effectiveness of this FDI framework. At the end, a circuit example is used to illustrate the effectiveness of this approach., The work was supported by the DGR of Generalitat de Catalunya (AGAUR Doctorat Industrial 2013-DI-041), European Commission through contract i-Sense (FP7-ICT-2009-6-270428), and China Scholarship Council (File No.2011629170)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault tolerance using robust MPC with set-based state estimation and active fault isolation

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
  • Niculescu, Silviu-Iulian
Trabajo presentado a la 53rd IEEE Conference on Decision and Control (CDC 2014), celebrada del 15 al 17 de diciembre en Los Angeles, California (US)., In this paper, a sensor fault-tolerant control (FTC) scheme using robust model predictive control (MPC) and set theoretic fault detection and isolation (FDI) is proposed. The MPC controller is used to both robustly control the plant and actively guarantee fault isolation (FI). In this scheme, fault detection (FD) is passive by interval observers, while fault isolation (FI) is active by MPC. The advantage of the proposed approach consists in using MPC to actively decouple the effect of sensor faults on the outputs such that one output component only corresponds to one sensor fault in terms of FI, which can utilize the feature of sensor faults for FI. A numerical example is used to illustrate the effectiveness of the proposed scheme., This work has been partially supported by the EU project i-Sense (FP7-ICT-2009-6-270428), China Scholarship Council, CNRS-Supelec and Automatic Control Department, Supélec, France., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Robust MPC for actuator-fault tolerance using set-based passive fault detection and active fault isolation

  • Xu, Feng
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
  • Niculescu, Silviu-Iulian
Trabajo presentado a la 53rd IEEE Conference on Decision and Control (CDC 2014), celebrada del 15 al 17 de diciembre en Los Angeles, California (US)., In this paper, an actuator fault-tolerant control (FTC) scheme is proposed, which is based on tube-based model predictive control (MPC) and set-based fault detection and isolation (FDI). As a robust MPC technique, tube-based MPC can effectively deal with system constraints and uncertainties with relatively low complexity. Set-based FDI can implement robust fault diagnosis. In this scheme, fault detection (FD) is passive by invariant sets, while fault isolation (FI) is active by MPC and tubes. Using the constraint-handling ability of MPC, an active FI approach is implemented. This paper is ended up with an example to illustrate the effectiveness of the scheme., This work has been partially supported by the EU project i-Sense (FP7-ICT-2009-6-270428), China Scholarship Council, CNRS-Supelec and Automatic Control Department, Supélec, France., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Robust Fault Detection using Polytope-based Set-membership Consistency Test

  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Saludes Closa, Jordi|||0000-0002-6666-1982
This article proposes a robust set-membership fault detection method based on the use of polytopes to bound the parameter uncertainty set. The proposed polytope-based fault detection algorithm is able to handle systems with bounded parameter variation between samples. It is shown that consistency checks indicating faults can be performed in a natural manner with a polytope description of the feasible parameter set.. Finally, an application example is given, which demonstrates how the algorithm works on a simulated process(a four-tank system). A comparison with a zonotope-based faultdetection approach recently proposed in the literature is included.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Robust MPC for actuator-fault tolerance using set-based passive fault detection and active fault isolation

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Olaru, Sorin
  • Niculescu, Silviu-Iulian
In this paper, an actuator fault-tolerant control (FTC) scheme is proposed, which is based on tube-based model predictive control (MPC) and set-theoretic fault detection and isolation (FDI). As a robust MPC technique, tube-based MPC, can effectively deal with system constraints and uncertainties with relatively low computational complexity. Set-based FDI can robustly detect and isolate actuator faults. Here, fault detection (FD) is passive by invariant sets, while fault isolation (FI) is active by tubes. Using the constraint-handling ability of MPC controllers, an active FI approach is implemented. A numerical example illustrates the effectiveness of the proposed approach.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Model-based optimal sensor placement approaches to fuel cell stack system fault diagnosis

  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Rosich Oliva, Albert
The problem of optimal sensor placement for FDI consists in d etermining the set of sensors that minimizes a pre-defined cost function satisfying at the same time a pre-established set of FDI specifications for a given set of faults. This paper recalls t hree model-based optimal sensor location approaches: an Incremental search, a Heuristic search and a Binary Integer Linear Programming (BILP) formulation. The main contribution of this paper is a compar ative study that addresses efficiency, flexibility and other issues. The performance of the approac hes is demonstrated by an application to a fuel cell stack system., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Closed-loop actuator-fault detection and isolation using invariant set and tubes

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes a new actuator-fault detection and isolation (FDI) strategy for closed-loop discrete time-invariant systems by using invariant sets and tubes. In this approach, invariant sets are used for fault detection (FD) and the establishment of FDI conditions, while the tubes are generated for fault isolation (FI) at transient state. Comparing with the existing set-theoretic FDI techniques, the advantage of this approach consists in that it exhibits a balance between the conservativeness of FDI conditions, the fast FI response and the computational complexity. The eectiveness of the proposed technique is illustrated by a numerical example.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Searching force-closure optimal grasps of articulated 2D objects with n links

  • Alvarado Tovar, Noé
  • Suárez Feijóo, Raúl|||0000-0002-3853-7095
This paper proposes a method that finds a locally optimal grasp of an articulated 2D object with n links considering frictionless contacts. The surface of each link of the object is represented by a finite set of points, thus it may have any shape. The proposed approach finds, first, an initial force-closure grasp and from it starts an iterative search of a local optimum grasp. The quality measure considered in this work is the largest perturbation wrench that a grasp can resist with independence of the direction of the perturbation. The approach has been implemented and some illustrative examples are included in the article.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault tolerance using robust MPC with set-based state estimation and active fault isolation

  • Xu, Feng
  • Olaru, Sorin
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Niculescu, Silviu-Iulian
In this paper, a sensor fault-tolerant control (FTC) scheme using robust model predictive control (MPC) and set theoretic fault detection and isolation (FDI) is proposed. The MPC controller is used to both robustly control the plant and actively guarantee fault isolation (FI). In this scheme, fault detection (FD) is passive by interval observers, while fault isolation (FI) is active by MPC. The advantage of the proposed approach consists in using MPC to actively decouple the effect of sensor faults on the outputs such that one output component only corresponds to one sensor fault in terms of FI, which can utilize the feature of sensor faults for FI. A numerical example is used to illustrate the effectiveness of the proposed scheme.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Fault detection and isolation based on the combination of a bank of interval observers and invariant sets

  • Xu, Feng
  • Stoican, Florin
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Olaru, Sorin
In this paper, a fault detection and isolation (FDI) approach using a bank of interval observers is developed. From the methodological point of view, a bank of interval observers is designed according to different dynamical models of the system under different modes (healthy or faulty). Each interval observer matches one system mode while all the interval observers monitor the system simultaneously. In order to guarantee FDI, a set of FDI conditions based on invariant set notions are established. These conditions ensure that the considered faults can be accurately isolated after a period of monitoring time. Finally, simulation results are used to present the effectiveness of the approach.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Fault Diagnosis of a Wind Farm using Interval Parity Equations

  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Jiménez, P.
  • Rotondo, Damiano|||0000-0002-8855-5582
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
Segon Premi a la "Competition on Wind Farm Fault Accomodation", atorgat per l'Aalborg University, al 19th. World Congress of the International Federation of Automatic Control, In this paper, the problem of fault diagnosis of a wind farm is addressed using interval parity equations. Fault detection is based on the use of parity equations and unknown but bounded description of the noise and modeling errors. The fault detection test is based on checking the consistency between the measurements and the model by finding if the formers are inside the interval prediction bounds. The fault isolation algorithm is based on analyzing the observed fault signatures on-line, and matching them with the theoretical ones obtained using structural analysis. Finally, the proposed approach is tested using the wind farm benchmark proposed in the context of the wind farm FDI/FTC competition., Peer Reviewed, Award-winning
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

On the relationship between interval observers and invariant sets in fault detection

  • Xu, Feng
  • Stoican, Florin
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Olaru, Sorin
In this paper, the relationship between two settheoretic fault detection (FD) approaches, the interval observerbased and the invariant set-based approaches, is investigated. In FD, interval observers monitor the system dynamic behavior in real time and generates adaptive intervals for system outputs. Invariant sets focus more on steady state behavior of the system rather than the transient behavior. This paper discusses these two approaches, presents the relationship between them and compares them in the FD task. At the end, a numerical example is used to illustrate the relation between these two approaches.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Improved fault detection and isolation strategy using a bank of interval observers

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an improved algorithm for actuator-fault detection and isolation (FDI) using a bank of interval observers is presented, where each interval observer matches one considered system mode. In this approach, interval observers and invariant sets are simultaneously used for FDI. Under a collection of improved FDI conditions, this new algorithm can detect and isolate the considered actuator faults. At the end of this paper, a circuit example is used to illustrate the e ectiveness of the proposed strategy
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization under budgetary constraints

  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Rosich Oliva, Albert
The success of any diagnosis strategy critically depends on the sensors measuring process variables. This paper presents a strategy based on diagnosability maximization for optimally locating sensors in distribution networks. The goal is to characterize and determine the set of sensors that guarantees a maximum degree of diagnosability taking into account a given sensor configuration cardinality constraint. The strategy is based on the structural model of the system under consideration. Structural analysis is a powerful tool for determining diagnosis possibilities and evaluating whether the number and the location of sensors are adequate in order to meet some diagnosis specifications. The proposed approach is successfully applied to leakage detection in a Drinking Water Distribution Network., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Actuator-fault detection and isolation based on interval observers and invariant sets

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes an interval observer-based actuator fault detection and isolation (FDI) approach. An interval observer matching the healthy system mode is designed to monitor the system. When the system is in different modes, state or output interval vectors predicted by the interval observer manifest different dynamical behaviors. To guarantee reliable FDI, a collection of invariant set-based FDI conditions are established. Under these conditions, actuator faults can be accurately detected and isolated during the transition between different modes. At the end, the effectiveness of this proposed approach is presented by using a numerical example.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

A model for a multiresolution time series database system

  • Llusà Serra, Aleix|||0000-0002-1682-9564
  • Escobet Canal, Teresa|||0000-0001-6090-1538
  • Vila Marta, Sebastià|||0000-0001-9069-1340
In this paper we propose a model for multiresolution time series database management systems. Thismodel stores compactly a time series and manages consistently its temporal dimension. This is achieved byextracting different resolutions and attributes summaries from the original time series. Our work is concerned inputting together two areas of study: time series analysis and database management systems. Time series analysisoffers a great deal of methodologies and algorithms to process time series data. Database systems field providessoftware expertise in managing data. Therefore, for many applications it is of primary relevance that databasesystems support time series., The research presented in this paper has been supported by Spanish research project NASP (TEC2012-35571), SHERECS (DPI2011-26243), the UE project i-Sense (FP7-ICT-270428), and Universitat Politècnica de Catalunya, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

A service reliability model predictive control with dynamic safety stocks and actuators health monitoring for drinking water networks

  • Grosso Pérez, Juan Manuel|||0000-0002-4300-1500
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
This paper presents a model predictive control strategy to assure reliability in drinking water networks given a customer service level and a forecasting demand. The underlying idea concerns a two-layer hierarchical control structure. The upper layer performs a local steady-state optimization to set up an inventory replenishment policy based on dynamic safety stocks for each tank in the network. At the same stage, actuators health is revised to set up their next maximum allowable degradation in order to efficiently distribute overall control effort and guarantee system availability. In the lower layer, a model predictive control algorithm is implemented to compute optimal control set-points to minimize a multiobjective cost function. Simulation results in the Barcelona drinking water network have shown the effectiveness of the dynamic safety stocks allocation and the actuators health monitoring to assure service reliability and optimizing network operational costs., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization in distribution networks

  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Rosich Oliva, Albert
The success of any diagnosis strategy critically depends on the sensors measuring process variables. This paper presents a strategy based on diagnosability maximization for optimally locating sensors in distribution networks. The goal is to characterize and determine the set of sensors that guarantee a maximum degree of diagnosability taking into account a given sensor configuration cardinality constraint. The strategy is based on the structural model of the system under consideration. Structural analysis is a powerful tool for determining diagnosis possibilities and evaluating whether the number and the location of sensors are adequate in order to meet some diagnosis specifications. The proposed approach is successfully applied to leakage detection in a Drinking Water Distribution Network., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Garza Castañón, Luís Eduardo
  • Rosich, Albert
In this paper, a new approach for sensor placement in water distribution networks (WDN) is proposed. The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the non-linear integer and largescale nature of the resulting optimization problem, genetic algorithms (GA) are used as solution approach. To validate the results obtained, they are compared with exhaustive search methods with higher computational cost proving that GA allow to find near-optimal solutions with less computational load. The proposed sensor placement algorithm is combined with a projection-based isolation scheme. However, the proposed methodology does not depend on the isolation method chosen by the user and it could be easily adapted to any other isolation scheme. Experiments on a real network allow to evaluate the performance of such approach.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Methodology for actuator fault tolerance evaluation of linear constrained MPC: application to the Barcelona water network

  • Robles, Deneb
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Garza Castañón, Luís Eduardo
This paper presents a methodology to evaluate the admissibility of actuator fault configurations (AFC) when Linear Constrained Model Predictive Control (LCMPC) is used. The methodology combines the use of structural and feasability analysis. Structural analysis allows to evaluate the loss of reachability after a fault occurrence. The results of the structural analysis can be complemented with the feasibility analysis of the MPC problem taking into account the effect of actuator constraints after the fault occurrence. Additionally, a degradation analysis of the system performance can also be included. The proposed methodology is tested in the Barcelona water network.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak detection and location in water distribution networks

  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Quevedo Casín, Joseba Jokin|||0000-0002-7827-2896
The performance of a leak detection and location algorithm depends on the set of measurements that are available in the network. This works presents and optimization strategy that maximizes the leak diagnosability performance of the network. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of disnosability while the sensor configuration cost satifies a budgetary constraint. To efficiently handle the complexity of the distribuion networl an efficient branch and bound search strategy based on a strucutrual model is used. However, in order to reduce even more the size and the complexity of the problem the present work proposes to combine this methodology with clustering techniques. The strategy developed in this work is successfully applied to determine the optimal set of pressure sensors that should be installed to a District Metered Area in the Baarcelona Water Distribution Network., Peer Reviewed, Award-winning
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Improved fault detection and isolation strategy using a bank of interval observers

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an improved algorithm for actuator-fault detection and isolation (FDI) using a bank of interval observers is presented, where each interval observer matches one considered system mode. In this approach, interval observers and invariant sets are simultaneously used for FDI. Under a collection of improved FDI conditions, this new algorithm can detect and isolate the considered actuator faults. At the end of this paper, a circuit example is used to illustrate the eectiveness of the proposed strategy.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault detection and Isolation using Interval Observers

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes an interval observer-based sensor fault detection and isolation (FDI) approach for the closed-loop systems. In this proposed approach, residuals are defined in such a way that their components are independent of each other at the time instant after fault occurrence, namely kf + 1, where kf denotes the fault occurrence time instant. In this way, it is guaranteed that at kf + 1 the changes in each component of the residuals are only related to the fault in the corresponding sensor. By detecting the threshold violation of the corresponding residual interval components, the proposed method can detect and isolate sensor faults at that time instant. At the end of this paper, a numerical example is used to present the effectiveness of the approach.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Methodology for actuator fault tolerance evaluation of linear constrained MPC: application to the Barcelona water network

  • Robles, Deneb
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Garza Castañón, Luís Eduardo
This paper presents a methodology to evaluate the admissibility of actuator fault configurations (AFC) when Linear Constrained Model Predictive Control (LCMPC) is used. The methodology combines the use of structural and feasability analysis. Structural analysis allows to evaluate the loss of reachability after a fault occurrence. The results of the structural analysis can be complemented with the feasibility analysis of the MPC problem taking into account the effect of actuator constraints after the fault occurrence. Additionally, a degradation analysis of the system performance can also be included. The proposed methodology is tested in the Barcelona water network., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Fault Diagnosis of a Wind Farm using Interval Parity Equations

  • Blesa Izquierdo, Joaquim
  • Jiménez, P.
  • Rotondo, Damiano
  • Nejjari Akhi-Elarab, Fatiha
  • Puig Cayuela, Vicenç
Segon Premi a la "Competition on Wind Farm Fault Accomodation", atorgat per l'Aalborg University, al 19th. World Congress of the International Federation of Automatic Control, In this paper, the problem of fault diagnosis of a wind farm is addressed using interval parity equations. Fault detection is based on the use of parity equations and unknown but bounded description of the noise and modeling errors. The fault detection test is based on checking the consistency between the measurements and the model by finding if the formers are inside the interval prediction bounds. The fault isolation algorithm is based on analyzing the observed fault signatures on-line, and matching them with the theoretical ones obtained using structural analysis. Finally, the proposed approach is tested using the wind farm benchmark proposed in the context of the wind farm FDI/FTC competition., Peer Reviewed, Award-winning, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak detection and location in water distribution networks

  • Sarrate Estruch, Ramon
  • Blesa Izquierdo, Joaquim
  • Nejjari Akhi-Elarab, Fatiha
  • Quevedo Casín, Joseba Jokin
The performance of a leak detection and location algorithm depends on the set of measurements that are available in the network. This works presents and optimization strategy that maximizes the leak diagnosability performance of the network. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of disnosability while the sensor configuration cost satifies a budgetary constraint. To efficiently handle the complexity of the distribuion networl an efficient branch and bound search strategy based on a strucutrual model is used. However, in order to reduce even more the size and the complexity of the problem the present work proposes to combine this methodology with clustering techniques. The strategy developed in this work is successfully applied to determine the optimal set of pressure sensors that should be installed to a District Metered Area in the Baarcelona Water Distribution Network., Peer Reviewed, Award-winning, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Fault detection and isolation based on the combination of a bank of interval observers and invariant sets

  • Xu, Feng
  • Stoican, Florin
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
In this paper, a fault detection and isolation (FDI) approach using a bank of interval observers is developed. From the methodological point of view, a bank of interval observers is designed according to different dynamical models of the system under different modes (healthy or faulty). Each interval observer matches one system mode while all the interval observers monitor the system simultaneously. In order to guarantee FDI, a set of FDI conditions based on invariant set notions are established. These conditions ensure that the considered faults can be accurately isolated after a period of monitoring time. Finally, simulation results are used to present the effectiveness of the approach., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Model-based optimal sensor placement approaches to fuel cell stack system fault diagnosis

  • Sarrate Estruch, Ramon
  • Nejjari Akhi-Elarab, Fatiha
  • Rosich Oliva, Albert
The problem of optimal sensor placement for FDI consists in d etermining the set of sensors that minimizes a pre-defined cost function satisfying at the same time a pre-established set of FDI specifications for a given set of faults. This paper recalls t hree model-based optimal sensor location approaches: an Incremental search, a Heuristic search and a Binary Integer Linear Programming (BILP) formulation. The main contribution of this paper is a compar ative study that addresses efficiency, flexibility and other issues. The performance of the approac hes is demonstrated by an application to a fuel cell stack system., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

On the relationship between interval observers and invariant sets in fault detection

  • Xu, Feng
  • Stoican, Florin
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
In this paper, the relationship between two settheoretic fault detection (FD) approaches, the interval observerbased and the invariant set-based approaches, is investigated. In FD, interval observers monitor the system dynamic behavior in real time and generates adaptive intervals for system outputs. Invariant sets focus more on steady state behavior of the system rather than the transient behavior. This paper discusses these two approaches, presents the relationship between them and compares them in the FD task. At the end, a numerical example is used to illustrate the relation between these two approaches., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Improved fault detection and isolation strategy using a bank of interval observers

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an improved algorithm for actuator-fault detection and isolation (FDI) using a bank of interval observers is presented, where each interval observer matches one considered system mode. In this approach, interval observers and invariant sets are simultaneously used for FDI. Under a collection of improved FDI conditions, this new algorithm can detect and isolate the considered actuator faults. At the end of this paper, a circuit example is used to illustrate the eectiveness of the proposed strategy., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization under budgetary constraints

  • Sarrate Estruch, Ramon
  • Nejjari Akhi-Elarab, Fatiha
  • Rosich Oliva, Albert
The success of any diagnosis strategy critically depends on the sensors measuring process variables. This paper presents a strategy based on diagnosability maximization for optimally locating sensors in distribution networks. The goal is to characterize and determine the set of sensors that guarantees a maximum degree of diagnosability taking into account a given sensor configuration cardinality constraint. The strategy is based on the structural model of the system under consideration. Structural analysis is a powerful tool for determining diagnosis possibilities and evaluating whether the number and the location of sensors are adequate in order to meet some diagnosis specifications. The proposed approach is successfully applied to leakage detection in a Drinking Water Distribution Network., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault detection and Isolation using Interval Observers

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes an interval observer-based sensor fault detection and isolation (FDI) approach for the closed-loop systems. In this proposed approach, residuals are defined in such a way that their components are independent of each other at the time instant after fault occurrence, namely kf + 1, where kf denotes the fault occurrence time instant. In this way, it is guaranteed that at kf + 1 the changes in each component of the residuals are only related to the fault in the corresponding sensor. By detecting the threshold violation of the corresponding residual interval components, the proposed method can detect and isolate sensor faults at that time instant. At the end of this paper, a numerical example is used to present the effectiveness of the approach., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

A service reliability model predictive control with dynamic safety stocks and actuators health monitoring for drinking water networks

  • Grosso Pérez, Juan Manuel
  • Ocampo-Martínez, Carlos
  • Puig Cayuela, Vicenç
This paper presents a model predictive control strategy to assure reliability in drinking water networks given a customer service level and a forecasting demand. The underlying idea concerns a two-layer hierarchical control structure. The upper layer performs a local steady-state optimization to set up an inventory replenishment policy based on dynamic safety stocks for each tank in the network. At the same stage, actuators health is revised to set up their next maximum allowable degradation in order to efficiently distribute overall control effort and guarantee system availability. In the lower layer, a model predictive control algorithm is implemented to compute optimal control set-points to minimize a multiobjective cost function. Simulation results in the Barcelona drinking water network have shown the effectiveness of the dynamic safety stocks allocation and the actuators health monitoring to assure service reliability and optimizing network operational costs., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig Cayuela, Vicenç
  • Garza Castañón, Luís Eduardo
  • Rosich, Albert
In this paper, a new approach for sensor placement in water distribution networks (WDN) is proposed. The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the non-linear integer and largescale nature of the resulting optimization problem, genetic algorithms (GA) are used as solution approach. To validate the results obtained, they are compared with exhaustive search methods with higher computational cost proving that GA allow to find near-optimal solutions with less computational load. The proposed sensor placement algorithm is combined with a projection-based isolation scheme. However, the proposed methodology does not depend on the isolation method chosen by the user and it could be easily adapted to any other isolation scheme. Experiments on a real network allow to evaluate the performance of such approach., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Robust MPC for actuator-fault tolerance using set-based passive fault detection and active fault isolation

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Olaru, Sorin
  • Niculescu, Silviu-Iulian
In this paper, an actuator fault-tolerant control (FTC) scheme is proposed, which is based on tube-based model predictive control (MPC) and set-theoretic fault detection and isolation (FDI). As a robust MPC technique, tube-based MPC, can effectively deal with system constraints and uncertainties with relatively low computational complexity. Set-based FDI can robustly detect and isolate actuator faults. Here, fault detection (FD) is passive by invariant sets, while fault isolation (FI) is active by tubes. Using the constraint-handling ability of MPC controllers, an active FI approach is implemented. A numerical example illustrates the effectiveness of the proposed approach., Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Improved fault detection and isolation strategy using a bank of interval observers

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
In this paper, an improved algorithm for actuator-fault detection and isolation (FDI) using a bank of interval observers is presented, where each interval observer matches one considered system mode. In this approach, interval observers and invariant sets are simultaneously used for FDI. Under a collection of improved FDI conditions, this new algorithm can detect and isolate the considered actuator faults. At the end of this paper, a circuit example is used to illustrate the e ectiveness of the proposed strategy, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for fault diagnosis performance maximization in distribution networks

  • Sarrate Estruch, Ramon
  • Nejjari Akhi-Elarab, Fatiha
  • Rosich Oliva, Albert
The success of any diagnosis strategy critically depends on the sensors measuring process variables. This paper presents a strategy based on diagnosability maximization for optimally locating sensors in distribution networks. The goal is to characterize and determine the set of sensors that guarantee a maximum degree of diagnosability taking into account a given sensor configuration cardinality constraint. The strategy is based on the structural model of the system under consideration. Structural analysis is a powerful tool for determining diagnosis possibilities and evaluating whether the number and the location of sensors are adequate in order to meet some diagnosis specifications. The proposed approach is successfully applied to leakage detection in a Drinking Water Distribution Network., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Robust Fault Detection using Polytope-based Set-membership Consistency Test

  • Blesa Izquierdo, Joaquim
  • Puig Cayuela, Vicenç
  • Saludes Closa, Jordi
This article proposes a robust set-membership fault detection method based on the use of polytopes to bound the parameter uncertainty set. The proposed polytope-based fault detection algorithm is able to handle systems with bounded parameter variation between samples. It is shown that consistency checks indicating faults can be performed in a natural manner with a polytope description of the feasible parameter set.. Finally, an application example is given, which demonstrates how the algorithm works on a simulated process(a four-tank system). A comparison with a zonotope-based faultdetection approach recently proposed in the literature is included., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Searching force-closure optimal grasps of articulated 2D objects with n links

  • Alvarado Tovar, Noé
  • Suárez Feijóo, Raúl
This paper proposes a method that finds a locally optimal grasp of an articulated 2D object with n links considering frictionless contacts. The surface of each link of the object is represented by a finite set of points, thus it may have any shape. The proposed approach finds, first, an initial force-closure grasp and from it starts an iterative search of a local optimum grasp. The quality measure considered in this work is the largest perturbation wrench that a grasp can resist with independence of the direction of the perturbation. The approach has been implemented and some illustrative examples are included in the article., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

A model for a multiresolution time series database system

  • Llusà Serra, Aleix
  • Escobet Canal, Teresa
  • Vila Marta, Sebastià
In this paper we propose a model for multiresolution time series database management systems. Thismodel stores compactly a time series and manages consistently its temporal dimension. This is achieved byextracting different resolutions and attributes summaries from the original time series. Our work is concerned inputting together two areas of study: time series analysis and database management systems. Time series analysisoffers a great deal of methodologies and algorithms to process time series data. Database systems field providessoftware expertise in managing data. Therefore, for many applications it is of primary relevance that databasesystems support time series., The research presented in this paper has been supported by Spanish research project NASP (TEC2012-35571), SHERECS (DPI2011-26243), the UE project i-Sense (FP7-ICT-270428), and Universitat Politècnica de Catalunya, Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Actuator-fault detection and isolation based on interval observers and invariant sets

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes an interval observer-based actuator fault detection and isolation (FDI) approach. An interval observer matching the healthy system mode is designed to monitor the system. When the system is in different modes, state or output interval vectors predicted by the interval observer manifest different dynamical behaviors. To guarantee reliable FDI, a collection of invariant set-based FDI conditions are established. Under these conditions, actuator faults can be accurately detected and isolated during the transition between different modes. At the end, the effectiveness of this proposed approach is presented by using a numerical example., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor-fault tolerance using robust MPC with set-based state estimation and active fault isolation

  • Xu, Feng
  • Olaru, Sorin
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Niculescu, Silviu-Iulian
In this paper, a sensor fault-tolerant control (FTC) scheme using robust model predictive control (MPC) and set theoretic fault detection and isolation (FDI) is proposed. The MPC controller is used to both robustly control the plant and actively guarantee fault isolation (FI). In this scheme, fault detection (FD) is passive by interval observers, while fault isolation (FI) is active by MPC. The advantage of the proposed approach consists in using MPC to actively decouple the effect of sensor faults on the outputs such that one output component only corresponds to one sensor fault in terms of FI, which can utilize the feature of sensor faults for FI. A numerical example is used to illustrate the effectiveness of the proposed scheme., Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Closed-loop actuator-fault detection and isolation using invariant set and tubes

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes a new actuator-fault detection and isolation (FDI) strategy for closed-loop discrete time-invariant systems by using invariant sets and tubes. In this approach, invariant sets are used for fault detection (FD) and the establishment of FDI conditions, while the tubes are generated for fault isolation (FI) at transient state. Comparing with the existing set-theoretic FDI techniques, the advantage of this approach consists in that it exhibits a balance between the conservativeness of FDI conditions, the fast FI response and the computational complexity. The eectiveness of the proposed technique is illustrated by a numerical example., Postprint (published version)