Changes in QRS and T-wave Loops Subsequent to an Increase in Left Ventricle Globularity as in Intrauterine Growth Restriction: a Simulation Study

  • Bueno-Palomeque, Freddy L
  • Mountris, Konstantinos A
  • Mincholé, Ana
  • Bailón, Raquel
  • Pueyo, Esther
  • Laguna, Pablo
  • Ortigosa, Nuria|||0000-0002-5272-7661
[EN] Cardiovascular remodeling induced by intrauterine growth restriction manifests in adulthood by more globular ventricles, as evidenced by in vivo measurements. The angle between the dominant vectors of the QRS and T-wave loops has been reported to be significantly altered as a result of the induced remodeling. To investigate whether the more globular ventricular shape was a major factor contributing to such alteration, we performed electrophysiological simulations in a human biventricular model for control and in a model obtained by deforming the control one to represent a more spherical left ventricle (SLV). Transmural ventricular heterogeneities and a Purkinje network were included. 12-lead ECGs were calculated, from which spatial QRS and T-wave angles were computed. The angle between the T-wave and the XZ-plane was found to increase in the SLV model, showing a variation similar to that reported in in vivo studies. However, the angle between the dominant vectors of the QRS and T-wave loops projected onto the XY-plane was lower for control, contrary to clinical observations in IUGR adults. Other clinical results could not be reproduced in our simulations either. Our findings suggest that a more globular left ventricular shape leads to changes in the angles of QRS and T-wave loops, but further research is needed to fully understand these changes and the underlying mechanisms, I would like to acknowledge support by Fundaci ' on Carolina, Universidad de Zaragoza and Universidad Polit ' ecnica Salesiana through its doctoral scholar-ship. This work was supported by projects ERC-StG 638284 (ERC), PID2019-105674RB-I00 and PID2019104881RB-I00 (MICINN) and LMP124-18 and reference group T39-20R (Arag ' on Government cofunded by FEDER 2014-2020 "Building Europe from Aragon"). Computations were performed using ICTS NANBIOSIS (HPC unit at U. Zaragoza). N. Ortigosa acknowledges support from Generalitat Valenciana under grant Prometeo/2017/102 and Spanish MINECO under grant MTM2016-76647-P
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Improving signal stability in a multi-electrode array (MEA) system for cardiac biopsies

  • Velarte, A.
  • Otín, A.
  • Pueyo, E.
  • Guimera, A.
  • Villa, R.
This work evaluates the performance of a microelectrode array (MEA) to be used in a specific platform dedicated for measuring field potentials of small human cardiac samples. A test bench has been developed to characterize the electrodes by measuring their impedance as well as to modify their characteristic curve using a replatinization process, where black platinum is deposited on the indicated areas of the MEA flex-pcb. This set-up consists of the array of microelectrodes made of gold, together with its corresponding electronic adapter board, a potentiostat and an electrochemical interface. Phosphate buffered saline (PBS), which is commonly considered for this type of analysis, has been used for impedance characterization. Initially, the impedance presents a highly variable behavior at different frequencies as well as between the different channels of the array. Once the platinization process has been carried out, the impedance in all the recording channels is very similar and has decreased over a large part of the frequency range under study. A complete electrical model of the electrodes has been proposed and analyzed, achieving better results by including the mathematical constant phase element (CPE) associated with capacitive behavior (model fitting error < 2%). Finally, the characterization of the different noise contributions has been carried out. Based on the obtained results, it can be concluded that the evaluated system allows the recording of field potential signals from small human cardiac tissues.