Pasar al contenido principal

TOWARDS IMPROVED MANAGEMENT OF CARDIOVASCULAR DISEASES BY INTEGRATIVE IN SILICO-IN VITRO-IN VIVO RESEARCH INTO HEART’S STRUCTURE, FUNCTION AND AUTONOMIC REGULATION

PID2019-105674RB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 74
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

QRS-T angles as markers for heart sphericity in subjects with intrauterine growth restriction: a simulation study

  • Bueno-Palomeque, Freddy L.
  • Mountris, Konstantinos A.
  • Ortigosa, Núria
  • Bailón, Raquel
  • Bijnens, Bart
  • Crispi Brillas, Fàtima
  • Pueyo, Esther
  • Mincholé, Ana
  • Laguna, Pablo
This work was supported in part by Fundación Carolina and Universidad Politénica Salesiana, in part by the Spanish Ministry of Science and Innovation (MICINN) and FEDER Una manera de hacer Europa under Grants PID2019-105674RB-I00, PID2021-128972OA-I00, TED2021-130459B-I00, and PID2020-119457GB-100, through Ramon y Cajal Program under Grant RYC2019-027420-I, in part by the Gobierno de Aragon, Reference Group BSICoS T39-20R, and in part by Project LMP94_21.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Meshless electrophysiological modeling of cardiac resynchronization therapy: benchmark analysis with finite-element methods in experimental data

  • Albors Lucas, Carlos
  • Lluch Álvarez, Èric
  • Gomez, Juan Francisco
  • Cedilnik, Nicolas
  • Mountris, Konstantinos A.
  • Mansi, Tommaso
  • Khamzin, Svyatoslav
  • Dokuchaev, Arsenii
  • Solovyova, Olga
  • Pueyo, Esther
  • Sermesant, Maxime
  • Sebastian, Rafael
  • Morales, Hernán G.
  • Camara, Oscar
Computational models of cardiac electrophysiology are promising tools for reducing the rates of non-response patients suitable for cardiac resynchronization therapy (CRT) by optimizing electrode placement. The majority of computational models in the literature are mesh-based, primarily using the finite element method (FEM). The generation of patient-specific cardiac meshes has traditionally been a tedious task requiring manual intervention and hindering the modeling of a large number of cases. Meshless models can be a valid alternative due to their mesh quality independence. The organization of challenges such as the CRT-EPiggy19, providing unique experimental data as open access, enables benchmarking analysis of different cardiac computational modeling solutions with quantitative metrics. We present a benchmark analysis of a meshless-based method with finite-element methods for the prediction of cardiac electrical patterns in CRT, based on a subset of the CRT-EPiggy19 dataset. A data assimilation strategy was designed to personalize the most relevant parameters of the electrophysiological simulations and identify the optimal CRT lead configuration. The simulation results obtained with the meshless model were equivalent to FEM, with the most relevant aspect for accurate CRT predictions being the parameter personalization strategy (e.g., regional conduction velocity distribution, including the Purkinje system and CRT lead distribution)., This work was supported in part by the Spanish Ministry of Science and Innovation (TIN2011-28067, REDINSCOR RD06/003/008, PID2019-105674RB-I00), the Spanish Industrial and Technological Development Center (cvREMOD-CEN-20091044), the Spanish Ministry of Economy and Competitiveness under the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502), the Government of Aragón (Spain) (LMP94_21), the Directorate General of Science Policy of the Generalitat Valenciana (Spain) (PROMETEU 2016/088), the Seventh Framework Programme (FP7/2007-2013) for research, technological and demonstration under grant agreement VP2HF (no. 611823), by the RSF grant no. 19-14-00134, and by European Regional Development Fund (ERDF) DPI2016-75799-R (AEI/ERDF, EU).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Characterization of Atrial Propagation Patterns and Fibrotic Substrate With a Modified Omnipolar Electrogram Strategy in Multi-Electrode Arrays

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher-Ventura, Sara
  • Martínez-Mateu, Laura
  • Laranjo, Sergio
  • Laguna, Pablo
  • Martínez, Juan Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Introduction: The omnipolar electrogram method was recently proposed to try to generate orientation-independent electrograms. It estimates the electric field from the bipolar electrograms of a clique, under the assumption of locally plane and homogeneous propagation. The local electric field evolution over time describes a loop trajectory from which omnipolar signals in the propagation direction, substrate and propagation features, are derived. In this work, we propose substrate and conduction velocity mapping modalities based on a modified version of the omnipolar electrogram method, which aims to reduce orientation-dependent residual components in the standard approach. Methods: A simulated electrical propagation in 2D, with a tissue including a circular patch of diffuse fibrosis, was used for validation. Unipolar electrograms were calculated in a multi-electrode array, also deriving bipolar electrograms along the two main directions of the grid. Simulated bipolar electrograms were also contaminated with real noise, to assess the robustness of the mapping strategies against noise. The performance of the maps in identifying fibrosis and in reproducing unipolar reference voltage maps was evaluated. Bipolar voltage maps were also considered for performance comparison. Results: Results show that the modified omnipolar mapping strategies are more accurate and robust against noise than bipolar and standard omnipolar maps in fibrosis detection (accuracies higher than 85 vs. 80% and 70%, respectively). They present better correlation with unipolar reference voltage maps than bipolar and original omnipolar maps (Pearson's correlations higher than 0.75 vs. 0.60 and 0.70, respectively). Conclusion: The modified omnipolar method improves fibrosis detection, characterization of substrate and propagation, also reducing the residual sensitivity to directionality over the standard approach and improving robustness against noise. Nevertheless, studies with real electrograms will elucidate its impact in catheter ablation interventions., This study has received funding from the European Union's Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No 766082 (MY-ATRIA project), from projects PID2019-104881RB-I00, and PID2019-105674RB-I00 from MICINN, Spain, from Gobierno de Aragon (BSICoS Group T39-20R) cofunded by FEDER 20142020 Building Europe from Aragon and from Generalitat Valenciana through the fellowship ACIF/2018/174 and the grant PROMETEO/2020/043.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Cardiac computational modelling, Modelización computacional cardiaca

  • Bragard, Jean R.
  • Cámara, Óscar
  • Echebarria, Blas
  • Giorda, Luca Gerardo
  • Pueyo, Esther
  • Sebastián, Rafael
  • Soudah, Eduardo
  • Vázquez, Mariano
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Cardiovascular diseases currently have a major social and economic impact, constituting one of the leading causes of mortality and morbidity. Personalized computational models of the heart are demonstrating their usefulness both to help understand the mechanisms underlying cardiac disease, and to optimize their treatment and predict the patient's response. Within this framework, the Spanish Research Network for Cardiac Computational Modelling (VHeart-SN) has been launched. The general objective of the VHeart-SN network is the development of an integrated, modular and multiscale multiphysical computational model of the heart. This general objective is addressed through the following specific objectives: a) to integrate the different numerical methods and models taking into account the specificity of patients; b) to assist in advancing knowledge of the mechanisms associated with cardiac and vascular diseases; and c) to support the application of different personalized therapies. This article presents the current state of cardiac computational modelling and different scientific works conducted by the members of the network to gain greater understanding of the characteristics and usefulness of these models., [ES] Las enfermedades cardiovasculares tienen en la actualidad un gran impacto social y económico y constituyen una de las principales causas de mortalidad y morbilidad. Los modelos computacionales personalizados del corazón están demostrando ser útiles tanto para ayudar a comprender los mecanismos subyacentes a las patologías cardiacas como para optimizar su tratamiento prediciendo la respuesta del paciente. En este contexto, se ha puesto en marcha la Red Española de Investigación en Modelización Computacional Cardiaca (V-Heart SN). El objetivo general de V-Heart SN es el desarrollo de un modelo computacional multifísico y multiescala integrado del corazón. Este objetivo general se aborda a través de los siguientes objetivos específicos: a) integrar los diferentes modelos numéricos teniendo en cuenta la especificidad de los pacientes; b) ayudar a avanzar en el conocimiento de los mecanismos asociados a las diferentes patologías cardiacas y vasculares; y c) apoyar la aplicación de terapias personalizadas. Este artículo presenta el estado actual de la modelización computacional cardiaca y los diferentes trabajos científicos desarrollados por los miembros de la red para favorecer una mayor comprensión de las características y utilidad de los modelos., This work was partially supported by: Acciones de Dinamización Redes de Excelencia 2016, Plan Estatal de Investigación Científica y Técnica y de Innovación, Ministerio de Economía y Competitividad (DPI2016-81873-REDT) and CompBioMed2, Grant agreement ID: 823712. The authors also thank the support of the European Research Council (ERC-StG 638284) and the Spanish Goverment through the following programmes: Retos I+D (TIN2014-59932-JIN, RTI2018-093416-B-I00, SAF2017-88019-C3-3R, RTI2018- 101193-B-I00, DPI2016-75799-R and PID2019-105674RB-I00); María de Maeztu (MDM-2015-0502); and Severo Ochoa (SEV2017-0718 and CEX2018-000797-S)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Atrial fibrosis identification with unipolar electrogram eigenvalue distribution analysis in multi-electrode arrays

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher, Sara
  • Martínez-Mateu, Laura
  • Invers-Rubio, Eric
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Atrial fibrosis plays a key role in the initiation and progression of atrial fibrillation (AF). Atrial fibrosis is typically identified by a peak-to-peak amplitude of bipolar electrograms (b-EGMs) lower than 0.5 mV, which may be considered as ablation targets. Nevertheless, this approach disregards signal spatiotemporal information and b-EGM sensitivity to catheter orientation. To overcome these limitations, we propose the dominant-to-remaining eigenvalue dominance ratio (EIGDR) of unipolar electrograms (u-EGMs) within neighbor electrode cliques as a waveform dispersion measure, hypothesizing that it is correlated with the presence of fibrosis. A simulated 2D tissue with a fibrosis patch was used for validation. We computed EIGDR maps from both original and time-aligned u-EGMs, denoted as R and R-A, respectively, also mapping the gain in eigenvalue concentration obtained by the alignment, Delta R-A. The performance of each map in detecting fibrosis was evaluated in scenarios including noise and variable electrode-tissue distance. Best results were achieved by R-A, reaching 94% detection accuracy, versus the 86% of b-EGMs voltage maps. The proposed strategy was also tested in real u-EGMs from fibrotic and non- fibrotic areas over 3D electroanatomical maps, supporting the ability of the EIGDRs as fibrosis markers, encouraging further studies to confirm their translation to clinical settings., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was supported by European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 766082 and No. 860974, by projects PID2019-105674RBI00, PID2019-104881RB-I00 (MICINN) and Aragon Government (Reference Group Biomedical Signal Interpretation and Computational Simulation (BSICoS) T39-20R) cofunded by FEDER 20142020 "Building Europe from Aragon", by fellowship ACIF/2018/174 and Grant PROMETEO/2020/043, both from Direccion General de Politica Cientifica de la Generalitat Valenciana, and by DENIS Project (Volunteer Computer platform) supported through CoMBA 2021-2022 internal projects call from Universidad San Jorge.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Changes in QRS and T-wave Loops Subsequent to an Increase in Left Ventricle Globularity as in Intrauterine Growth Restriction: a Simulation Study

  • Bueno-Palomeque, Freddy L
  • Mountris, Konstantinos A
  • Mincholé, Ana
  • Bailón, Raquel
  • Pueyo, Esther
  • Laguna, Pablo
  • Ortigosa, Nuria|||0000-0002-5272-7661
[EN] Cardiovascular remodeling induced by intrauterine growth restriction manifests in adulthood by more globular ventricles, as evidenced by in vivo measurements. The angle between the dominant vectors of the QRS and T-wave loops has been reported to be significantly altered as a result of the induced remodeling. To investigate whether the more globular ventricular shape was a major factor contributing to such alteration, we performed electrophysiological simulations in a human biventricular model for control and in a model obtained by deforming the control one to represent a more spherical left ventricle (SLV). Transmural ventricular heterogeneities and a Purkinje network were included. 12-lead ECGs were calculated, from which spatial QRS and T-wave angles were computed. The angle between the T-wave and the XZ-plane was found to increase in the SLV model, showing a variation similar to that reported in in vivo studies. However, the angle between the dominant vectors of the QRS and T-wave loops projected onto the XY-plane was lower for control, contrary to clinical observations in IUGR adults. Other clinical results could not be reproduced in our simulations either. Our findings suggest that a more globular left ventricular shape leads to changes in the angles of QRS and T-wave loops, but further research is needed to fully understand these changes and the underlying mechanisms, I would like to acknowledge support by Fundaci ' on Carolina, Universidad de Zaragoza and Universidad Polit ' ecnica Salesiana through its doctoral scholar-ship. This work was supported by projects ERC-StG 638284 (ERC), PID2019-105674RB-I00 and PID2019104881RB-I00 (MICINN) and LMP124-18 and reference group T39-20R (Arag ' on Government cofunded by FEDER 2014-2020 "Building Europe from Aragon"). Computations were performed using ICTS NANBIOSIS (HPC unit at U. Zaragoza). N. Ortigosa acknowledges support from Generalitat Valenciana under grant Prometeo/2017/102 and Spanish MINECO under grant MTM2016-76647-P
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

QRS-T Angles as Markers for Heart Sphericity in Subjects With Intrauterine Growth Restriction: A Simulation Study

  • Bueno-Palomeque, Freddy L.
  • Mountris, Konstantinos A.
  • Bailón, Raquel
  • Bijnens, Bart
  • Crispi, Fátima
  • Pueyo, Esther
  • Mincholé, Ana
  • Laguna, Pablo
  • Ortigosa, Nuria|||0000-0002-5272-7661
[EN] Changes induced by intrauterine growth restriction (IUGR) in cardiovascular anatomy and function that persist throughout life have been associated with a higher predisposition to heart disease in adulthood. Together with cardiac morphological remodelling, evaluated through the ventricular sphericity index, alterations in cardiac electrical function have been reported by characterization of the depolarization and repolarization loops, and their angular relationship, measured from the vectorcardiogram. The underlying relationship between the morphological remodelling and the angular variation of QRS and T-wave dominant vectors, if any, has not been explored. The aim of this study was to evaluate this relationship using computational models based on realistic heart and torso in which IUGR-induced morphological changes were incorporated by reducing the ventricular sphericity index. Specifically, we departed from a control model and we built eight different globular heart models by reducing the base-to-apex length and enlarging the basal ventricular diameter. We computed QRS and T-wave dominant vectors and angles from simulated pseudo-electrocardiograms and we compared them with clinical measurements. Results for the QRS to T angles follow a change trend congruent with that reported in clinical data, supporting the hypothesis that the IUGR-induced morphological remodelling could contribute to explain the observed angle changes in IUGR patients. By additionally varying the position of the ventricles with respect to the torso and the electrodes, we found that electrode displacement can impact the quantified angles and should be considered when interpreting the results., This work was supported in part by Fundacion Carolina and Universidad Politenica Salesiana, in part by the Spanish Ministry of Science and Innovation (MICINN) and FEDER Una manera de hacer Europa under Grants PID2019-105674RB-I00, PID2021-128972OA-I00, TED2021-130459B-I00, and PID2020-119457GB-100, through Ramon y Cajal Program under Grant RYC2019-027420-I, in part by the Gobierno de Aragon, Reference Group BSICoS T39-20R, and in part by Project LMP94_21.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Fiber-Optic-Based System for High-Resolution Monitoring of Stretch in Excised Tissues

  • Velarte, Antonio
  • Otin, Aranzazu
  • Giménez-Gómez, Pablo
  • Muñoz-Berbel, Xavier
  • Pueyo, Esther
Cardiovascular diseases cause a high number of deaths nowadays. To improve these statistics, new strategies to better understand the electrical and mechanical abnormalities underlying them are urgently required. This study focuses on the development of a sensor to measure tissue stretch in excised tissues, enabling improved knowledge of biomechanical properties and allowing greater control in real time. A system made of biocompatible materials is described, which is based on two cantilevered platforms that integrate an optical fiber inside them to quantify the amount of stretch the tissues are exposed to with a precision of μ m. The operating principle of the sensor is based on the variation of the optical path with the movement of the platforms onto which the samples are fixed. The conducted tests highlight that this system, based on a simple topology and technology, is capable of achieving the desired purpose (a resolution of ∼1 μ m), enabling the tissue to be bathed in any medium within the system., This work was funded by projects PID2019-105674RB-I00, RTI2018-100773-B-C31, PID2021-127653NB-C21, PID2022-140556OB-I00 and TED2021-130459B-I00 by Ministerio de Ciencia e Innovación, ERC grant 638284 by European Research Council and projects LMP94_21 and BSICoS T39_23R by European Social Fund (EU) and Aragón Government., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Weighted time warping improves T-wave morphology markers clinical significance

  • Palmieri, Flavio|||0000-0002-1455-4923
  • Gomis Román, Pedro|||0000-0002-2058-7115
  • Ferreira, Dina
  • Pueyo, Esther
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Ramírez, Julia
Background: T-wave (TW) morphology indices based on time-warping (dw) have shown significant cardiovascular risk stratification value. However, errors in the location of TW boundaries may impact their prognostic power. Our aim was to test the hypothesis that a weighted time-warping function (WF) would reduce the sensitivity of dw to these errors and improve their clinical significance. Methods: The WFs were proportional to (i) the reference TW (T), and (ii) the absolute value of its derivative (D). The index dw was recalculated using these WFs, and its performance was compared to the unweighted control case (C) in four different scenarios: 1) robustness against simulated TW boundaries location errors; 2) ability to retain physiological information in an electrophysiological cardiac model; 3) ability to monitor blood potassium concentration changes ([K+]) in 29 hemodialysis (HD) patients; 4) and the sudden cardiac death (SCD) risk stratification value of the TW morphology restitution (TMR) index, derived from dw, in 651 chronic heart failure (CHF) patients. Results and Discussion: The WFs led to a reduced sensitivity (R) of dw to TW boundary location errors as compared to C (median R=0.19 and 0.22 and 0.35 for T, D and C, respectively). They also preserved the physiological relationship between dw and repolarization dispersion changes at ventricular level. No improvements in [K+] tracking were observed for the HD patients (Pearsons median correlation [r] between [K+] and dw was 0.86r0.90 for T, D and C). In CHF patients, the SCD risk stratification value of TMR was improved by applying T (hazard ratio, HAR, of 2.80), followed by D (HAR=2.32) and C (HAR=2.23). Conclusions and Significance: The proposed WFs, with T showing the best performance, increased the robustness of time-warping based markers against TW location errors preserving their physiological information content and boosting their SCD risk stratification value. Results from this work support the use of T when deriving dw for future clinical applications., This work was funded by Products&TechnologyS.L. (Castellbisbal,Barcelona,Spain),and by AGAUR,Generalitat de Catalunya (Spain) grant DI001-2018 and CIBER-BBN ref:“DEKOALE”.The work was also supported by project PID2019-104881RB-I00, and PID2019-105674 RB-I00 funded bySpanish Ministry of Science and Innovation (MICINN) and FEDER, by Gobierno de Aragón (Reference Group Biomedical Signal Interpretation and Computational Simulation (BSICoS)) T39-20 Rand projects LMP94-21,LMP14121cofunded by FEDER 2014-2020 “Building Europe from Aragón”, J.R. acknowledge the “María Zambrano” fellowship support from the European Union-Next Generation EU and the support from the Marie Sklodowska-Curie grant No786833. The computation was performed at the High Performance computing platform of the NANBIOSISICTS., Peer Reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Otros (Other)

Editorial: Perspectives of Antiarrhythmic Drug Therapy: Disappointing Past, Current Efforts, and Faint Hopes

  • Nánási, P.P.
  • Pueyo, E.
  • Virág, L.
Present issue is devoted to those areas of cardiac electrophysiology, pathophysiology, and pharmacology which are critically important to improve the efficacy of antiarrhythmic treatment. Cardiac arrhythmia is a leading cause of morbidity and mortality, and the history of anti-arrhythmic drug therapies has been dismal...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Automatic quantification of cardiomyocyte dimensions and connexin 43 lateralization in fluorescence images

  • Oliver-Gelabert, A.
  • García-Mendívil, L.
  • Vallejo-Gil, J.M.
  • Fresneda-Roldán, P.C.
  • Andelová, K.
  • Fañanás-Mastral, J.
  • Vázquez-Sancho, M.
  • Matamala-Adell, M.
  • Sorribas-Berjón, F.
  • Ballester-Cuenca, C.
  • Tribulova, N.
  • Ordovás, L.
  • Diez, E.R.
  • Pueyo, E.
Cardiomyocytes’ geometry and connexin 43 (CX43) amount and distribution are structural features that play a pivotal role in electrical conduction. Their quantitative assessment is of high interest in the study of arrhythmias, but it is usually hampered by the lack of automatic tools. In this work, we propose a software algorithm (Myocyte Automatic Retrieval and Tissue Analyzer, MARTA) to automatically detect myocytes from fluorescent microscopy images of cardiac tissue, measure their morphological features and evaluate the expression of CX43 and its degree of lateralization. The proposed software is based on the generation of cell masks, contouring of individual cells, enclosing of cells in minimum area rectangles and splitting of these rectangles into end-to-end and middle compartments to estimate CX43 lateral-to-total ratio. Application to human ventricular tissue images shows that mean differences between automatic and manual methods in terms of cardiomyocyte length and width are below 4 µm. The percentage of lateral CX43 also agrees between automatic and manual evaluation, with the interquartile range approximately covering from 3% to 30% in both cases. MARTA is not limited by fiber orientation and has an optimized speed by using contour filtering, which makes it run hundreds of times faster than a trained expert. Developed for CX43 studies in the left ventricle, MARTA is a flexible tool applicable to morphometric and lateralization studies of other markers in any heart chamber or even skeletal muscle. This open-access software is available online.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Heart Rate Variability and Exceptional Longevity

  • Hernández-Vicente, A.
  • Hernando, D.
  • Santos-Lozano, A.
  • Rodríguez-Romo, G.
  • Vicente-Rodríguez, G.
  • Pueyo, E.
  • Bailón, R.
  • Garatachea, N.
Centenarians are the paradigm of human extreme longevity and healthy aging, because they have postponed, if not avoided, mayor age-related diseases. The purpose of this study was to investigate potential differences in resting heart rate variability (HRV) between young adults, octogenarians, and centenarians and assess whether HRV variables are predictors of all-cause mortality in centenarians. To this end, three groups of participants: young adults (N = 20; 20.6 ± 2.3 years), octogenarians (N = 18; 84.1 ± 2.6 years), and centenarians (N = 17; 101.9 ± 1.9 years) were monitored for 15 min at rest (seated, without moving or talking) to measure RR intervals, from which HRV was evaluated. Our results showed a clear decrease with age in the main parasympathetic HRV variables, as well as in the standard deviation (SD) of the RR series [SD of normal-to-normal interval (SDNN)] and in low frequency (LF) heart rate (HR) oscillations, although differences between octogenarians and centenarians did not reach statistical significance. In 14 centenarians followed until death, only SDNN showed significant correlation (¿ = 0.536; p = 0.048) with survival prognosis. Additionally, SDNN <19 ms was associated with early mortality (=1 year) in centenarians (Hazard Ratio = 5.72). In conclusion, HRV indices reflecting parasympathetic outflow as well as SDNN and LF all present an age-related reduction, which could be representative of a natural exhaustion of allostatic systems related to age. Moreover, low SDNN values (<19 ms) could be associated with early mortality in centenarians. HRV seems to play a role in exceptional longevity, which could be accounted for by centenarians’ exposome.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Minimally invasive system to reliably characterize ventricular electrophysiology from living donors

  • Oliván-Viguera, A.
  • Pérez-Zabalza, M.
  • García-Mendívil, L.
  • Mountris, K.A.
  • Orós-Rodrigo, S.
  • Ramos-Marquès, E.
  • Vallejo-Gil, J.M.
  • Fresneda-Roldán, P.C.
  • Fañanás-Mastral, J.
  • Vázquez-Sancho, M.
  • Matamala-Adell, M.
  • Sorribas-Berjón, F.
  • Bellido-Morales, J.A.
  • Mancebón-Sierra, F.J.
  • Vaca-Núñez, A.S.
  • Ballester-Cuenca, C.
  • Marigil, M.Á.
  • Pastor, C.
  • Ordovás, L.
  • Köhler, R.
  • Diez, E.
  • Pueyo, E.
Cardiac tissue slices preserve the heterogeneous structure and multicellularity of the myocardium and allow its functional characterization. However, access to human ventricular samples is scarce. We aim to demonstrate that slices from small transmural core biopsies collected from living donors during routine cardiac surgery preserve structural and functional properties of larger myocardial specimens, allowing accurate electrophysiological characterization. In pigs, we compared left ventricular transmural core biopsies with transmural tissue blocks from the same ventricular region. In humans, we analyzed transmural biopsies and papillary muscles from living donors. All tissues were vibratome-sliced. By histological analysis of the transmural biopsies, we showed that tissue architecture and cellular organization were preserved. Enzymatic and vital staining methods verified viability. Optically mapped transmembrane potentials confirmed that action potential duration and morphology were similar in pig biopsies and tissue blocks. Action potential morphology and duration in human biopsies and papillary muscles agreed with published ranges. In both pigs and humans, responses to increasing pacing frequencies and ß-adrenergic stimulation were similar in transmural biopsies and larger tissues. We show that it is possible to successfully collect and characterize tissue slices from human myocardial biopsies routinely extracted from living donors, whose behavior mimics that of larger myocardial preparations both structurally and electrophysiologically.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of t wave amplitude, duration and morphology changes during hemodialysis: Relationship with serum electrolyte levels and heart rate

  • Bukhari, Syed Hassaan Ahmed
  • Palmieri, Flavio
  • Ramírez, Julia
  • Laguna, Pablo
  • Ruiz, José Esteban
  • Ferreira, Dina
  • Potse, Mark
  • Sánchez, Carlos
  • Pueyo, Esther
Objective: Chronic kidney disease affects more than 10% of the world population. Changes in serum ion concentrations increase the risk for ventricular arrhythmias and sudden cardiac death, particularly in end stage renal disease (ESRD) patients. We characterized how T wave amplitude, duration and morphology descriptors change with variations in serum levels of potassium and calcium and in heart rate, both in ESRD patients and in simulated ventricular fibers. Methods: Electrocardiogram (ECG) recordings from twenty ESRD patients undergoing hemodialysis (HD) and pseudo-ECGs (pECGs) calculated from twenty-two simulated ventricular fibers at varying transmural heterogeneity levels were processed to quantify T wave width (Tw), T wave slope-to-amplitude ratio (TS/A) and four indices of T wave morphological variability based on time warping (dw, dNLw, da and dNLa). Serum potassium and calcium levels and heart rate were measured along HD. Results: dNL with serum potassium, dw with calcium and da with heart rate, after correction for covariates. Median values of partial correlation coefficients were 0.75,−0.74 and −0.90, respectively. For all analyzed T wave descriptors, high inter-patient variability was observed in the pattern of such relationships. This variability, accentuated during the first HD time points, was reproduced in the simulations and shown to be influenced by differences in transmural heterogeneity. Conclusion: Changes in serum potassium and calcium levels and in heart rate strongly affect T wave descriptors, particularly those quantifying morphological variability. Significance: ECG markers have the potential to be used for monitoring serum ion concentrations in ESRD patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Atrial Dyssynchrony Measured by Strain Echocardiography as a Marker of Proarrhythmic Remodeling and Oxidative Stress in Cardiac Surgery Patients

  • Sanchez, F.J.
  • Gonzalez, V.A.
  • Farrando, M.
  • Baigorria Jayat, A.O.
  • Segovia-Roldan, M.
  • Garciá-Mendívil, L.
  • Ordovás, L.
  • Prado, N.J.
  • Pueyo, E.
  • Diez, E.R.
Aging leads to structural and electrophysiological changes that increase the risk of postoperative atrial arrhythmias; however, noninvasive preoperative markers of atrial proarrhythmic conditions are still needed. This study is aimed at assessing whether interatrial dyssynchrony determined using two-dimensional speckle tracking echocardiography relates to proarrhythmic structural and functional remodeling. A cohort of 45 patients in sinus rhythm referred for cardiac surgery was evaluated by echocardiography and surface electrocardiogram the day before the intervention. Transmembrane potential, connexin, and potassium channel distribution, inflammatory, and nitrooxidative markers were measured from right atrial tissue obtained from patients. A difference greater than 40 milliseconds between right and left atrial free wall contraction confirmed the presence of interatrial dyssynchrony in 21 patients. No difference in relation with age, previous diseases, and 2-dimensional echocardiographic findings as well as average values of global longitudinal right and left atrial strain were found between synchronic and dyssynchronic patients. Postoperative atrial fibrillation incidence increased from 8.3% in the synchronic group to 33.3% in the dyssynchronic ones. P wave duration showed no difference between groups. Action potentials from dyssynchronous patients decreased in amplitude, maximal rate of depolarization, and hyperpolarized. Duration at 30% of repolarization increased, being markedly shorter at 90% of repolarization. Only the dyssynchronous group showed early and delayed afterdepolarizations. Atrial tissue of dyssynchronous patients displayed lateralization of connexin 40 and increased connexin 43 expression and accumulation of tumor necrosis factor-a in the intercalated disc. Tumor necrosis factor-a did not colocalize, however, with lateralized connexin 40. Nitroxidative marks and KATP channels increased perivascularly and in myocytes. Our results demonstrate that, as compared to a traditional surface electrocardiogram, the novel noninvasive echocardiographic evaluation of interatrial dyssynchrony provides a better identification of nonaged-related proarrhythmic atrial remodeling with increased susceptibility to postoperative atrial fibrillation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Relationship between Atrial Oscillatory Acetylcholine Release Pattern and f-wave Frequency Modulation: a Computational and Experimental Study

  • Celotto, Chiara
  • Sánchez Tapia, Carlos
  • Mountris, Konstantinos
  • Abdollahpur, Mostafa
  • Sandberg, Frida
  • Laguna Lasaosa, Pablo
  • Pueyo Paúles, Esther
The frequency of fibrillatory waves (f-waves), F f , exhibits significant variation over time, and previous studies suggest that some of this variation is related to respiratory modulation through the autonomic nervous system. In this study, we tested the hypothesis that this variation (ΔF f ) could be related to acetylcholine concentration ([ACh]) release pattern. Electrocardiograms were recorded from seven patients during controlled respiration before and after full vagal blockade, from which f-wave frequency modulation was characterized. Computational simulations in human atrial tissues were performed to assess the effects of [ACh] release pattern on F f and compared to experimental results in humans. A cross-stimulation protocol was applied onto the tissue to initiate a rotor while cyclically varying [ACh] following a sinusoidal waveform of frequency equal to 0.125 Hz. Different mean levels (0.05, 0.075μM/l) and peak-to-peak ranges (0.1, 0.05, 0.025 μM/l) of [ACh] variation were tested. In all patients, an f-wave frequency modulation could be observed. In 57% of the patients, this modulation was significantly reduced after vagal blockade. Simulations confirmed that rotor frequency variations followed the induced [ACh] patterns. Mean F f was dependent on mean [ACh] level, whileΔF f was dependent on [ACh] variation range.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Monitoring blood potassium concentration in hemodialysis patients by quantifying T-wave morphology dynamics

  • Palmieri, F.
  • Gomis, P.
  • Ferreira, D.
  • Ruiz, J.E.
  • Bergasa, B.
  • Martín-Yebra, A.
  • Bukhari, H.A.
  • Pueyo, E.
  • Martínez, J.P.
  • Ramírez, J.
  • Laguna, P.
We investigated the ability of time-warping-based ECG-derived markers of T-wave morphology changes in time (dw) and amplitude (da), as well as their non-linear components (dNLw and dNLa), and the heart rate corrected counterpart (dw,c), to monitor potassium concentration ([K+]) changes (Δ[K+]) in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD). We compared the performance of the proposed time-warping markers, together with other previously proposed [K+] markers, such as T-wave width (Tw) and T-wave slope-to-amplitude ratio (TS/A), when computed from standard ECG leads as well as from principal component analysis (PCA)-based leads. 48-hour ECG recordings and a set of hourly-collected blood samples from 29 ESRD-HD patients were acquired. Values of dw, da, dNLw, dNLa and dw,c were calculated by comparing the morphology of the mean warped T-waves (MWTWs) derived at each hour along the HD with that from a reference MWTW, measured at the end of the HD. From the same MWTWs Tw and TS/A were also extracted. Similarly, Δ[K+] was calculated as the difference between the [K+] values at each hour and the [K+] reference level at the end of the HD session. We found that dw and dw,c showed higher correlation coefficients with Δ[K+] than TS/A—Spearman’s (ρ) and Pearson’s (r)—and Tw—Spearman’s (ρ)—in both SL and PCA approaches being the intra-patient median ρ≥0.82 and r≥0.87 in SL and ρ≥0.82 and r≥0.89 in PCA respectively. Our findings would point at dw and dw,c as the most suitable surrogate of Δ[K+], suggesting that they could be potentially useful for non-invasive monitoring of ESRD-HD patients in hospital, as well as in ambulatory settings. Therefore, the tracking of T-wave morphology variations by means of time-warping analysis could improve continuous and remote [K+] monitoring of ESRD-HD patients and flagging risk of [K+]-related cardiovascular events.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Validity of the polar h7 heart rate sensor for heart rate variability analysis during exercise in different age, body composition and fitness level groups

  • Hernández-Vicente, A.
  • Hernando, D.
  • Marín-Puyalto, J.
  • Vicente-Rodríguez, G.
  • Garatachea, N.
  • Pueyo, E.
  • Bailón, R.
This work aims to validate the Polar H7 heart rate (HR) sensor for heart rate variability (HRV) analysis at rest and during various exercise intensities in a cohort of male volunteers with different age, body composition and fitness level. Cluster analysis was carried out to evaluate how these phenotypic characteristics influenced HR and HRV measurements. For this purpose, sixty-seven volunteers performed a test consisting of the following consecutive segments: sitting rest, three submaximal exercise intensities in cycle-ergometer and sitting recovery. The agreement between HRV indices derived from Polar H7 and a simultaneous electrocardiogram (ECG) was assessed using concordance correlation coefficient (CCC). The percentage of subjects not reaching excellent agreement (CCC > 0.90) was higher for high-frequency power (PHF) than for low-frequency power (PLF) of HRV and increased with exercise intensity. A cluster of unfit and not young volunteers with high trunk fat percentage showed the highest error in HRV indices. This study indicates that Polar H7 and ECG were interchangeable at rest. During exercise, HR and PLF showed excellent agreement between devices. However, during the highest exercise intensity, CCC for PHF was lower than 0.90 in as many as 60% of the volunteers. During recovery, HR but not HRV measurements were accurate. As a conclusion, phenotypic differences between subjects can represent one of the causes for disagreement between HR sensors and ECG devices, which should be considered specifically when using Polar H7 and, generally, in the validation of any HR sensor for HRV analysis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Dynamical analysis of early afterdepolarization patterns in a biophysically detailed cardiac model

  • Barrio Gil, Roberto
  • Martinez Carballo, María Ángeles
  • Pueyo Paules, Esther
  • Serrano Pastor, Sergio
Arrhythmogenic early afterdepolarizations (EADs) are investigated in a biophysically detailed mathematical model of a rabbit ventricular myocyte, providing their location in the parameter phase space and describing their dynamical mechanisms. Simulations using the Sato model, defined by 27 state variables and 177 parameters, are conducted to generate electrical action potentials (APs) for different values of the pacing cycle length and other parameters related to sodium and calcium concentrations. A detailed study of the different AP patterns with or without EADs is carried out, showing the presence of a high variety of temporal AP configurations with chaotic and quasiperiodic behaviors. Regions of bistability are identified and, importantly, linked to transitions between different behaviors. Using sweeping techniques, one-, two-, and three-parameter phase spaces are provided, allowing ascertainment of the role of the selected parameters as well as location of the transition regions. A Devil’s staircase, with symbolic sequence analysis, is proposed to describe transitions in the ratio between the number of voltage (EAD and AP) peaks and the number of APs. To conclude, the obtained results are linked to recent studies for low-dimensional models and a conjecture is made for the internal dynamical structure of the transition region from non-EAD to EAD behavior using fold and cusp bifurcations and maximal canards. In a healthy heart, the sinoatrial node sends out an electrical impulse that spreads throughout the heart activating all cardiac myocytes to produce an electrical response called the action potential (AP). The AP follows a sequence of AP phases corresponding to the inflow and outflow of ions through the membrane of cardiac myocytes. Under some circumstances, that sequence of AP phases can be disrupted by the presence of the so-called early afterdepolarizations (EADs), which are secondary voltage depolarizations that can appear during phase 2 or 3 of the AP. Side effects of drugs, ion channel dysfunction, or oxidative stress, among others, can lead to the genesis of EADs.1–3 In heart failure, long QT syndrome, and other pathological conditions, EADs have been reported to be a relevant cause of fatal ventricular arrhythmias,4–6 but more knowledge is required to understand the theoretical mechanisms underlying their generation. During the last few decades, computational models of cardiac electrical activity have been instrumental in shedding light on various cardiac phenomena, including EADs. Biophysically detailed models of high dimension, i.e., with a large number of state variables, allow more faithful reproduction of experimental observations and facilitate biophysical interpretation. Here, we use the high-dimensional electrophysiological model of a rabbit ventricular myocyte developed by Sato et al.6 with 27 state variables and 177 model parameters. By combining different techniques for dynamical system analysis, we investigate the parameter phase space using three parameters reported to highly influence model dynamics.7 We identify regions in the phase space showing transitions from absence to presence of EADs through different temporal sequences of EADs. In these processes, dynamical phenomena are present, including bistability, chaos, fold, and cusp bifurcations. Putting all this information together and taking into account recent findings using low-dimensional models, we provide a conjecture about the internal dynamical structure of the transition region from absence to presence of EADs in the parameter phase space studied for the Sato model.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modelización computacional cardiaca

  • Bragard, J.R.
  • Camara, O.
  • Echebarria, B.
  • Gerardo Giorda, L.
  • Pueyo, E.
  • Saiz, J.
  • Sebastián, R.
  • Soudah, E.
  • Vázquez, M.
Cardiovascular diseases currently have a major social and economic impact, constituting one of the leading causes of mortality and morbidity. Personalized computational models of the heart are demonstrating their usefulness both to help understand the mechanisms underlying cardiac disease, and to optimize their treatment and predict the patient''s response. Within this framework, the Spanish Research Network for Cardiac Computational Modelling (VHeart-SN) has been launched. The general objective of the VHeart-SN network is the development of an integrated, modular and multiscale multiphysical computational model of the heart. This general objective is addressed through the following specific objectives: a) to integrate the different numerical methods and models taking into account the specificity of patients; b) to assist in advancing knowledge of the mechanisms associated with cardiac and vascular diseases; and c) to support the application of different personalized therapies. This article presents the current state of cardiac computational modelling and different scientific works conducted by the members of the network to gain greater understanding of the characteristics and usefulness of these models.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Estimation of the second ventilatory threshold through ventricular repolarization profile analysis

  • Milagro, J.
  • Hernández-Vicente, A.
  • Hernando, D.
  • Casajús, J.A.
  • Garatachea, N.
  • Bailón, R.
  • Pueyo, E.
Under the hypothesis that sympathetic control of ventricular repolarization may change once the second ventilatory threshold (VT2) has been reached, a novel methodology for non-invasive VT2 estimation based on the analysis of the T wave from the electrocardiogram (ECG) is proposed, and potential underlying physiological mechanisms are suggested. 25 volunteers (33.4 ± 5.2 years) underwent an incremental power cycle ergometer test (25 W/minute). During the test, respiratory gas exchange and multi-lead ECG were acquired. The former was employed to determine VT2, used here as a reference, whereas the latter was used to compute the temporal profiles of an index of ventricular repolarization instability (dT) and its low-frequency (LF) oscillations (LFdT). The sudden increases observed in dT and LFdT profiles above an established heart rate threshold were employed to derive VT2 estimates, referred to as VT2dT and VT2LFdT, respectively. Estimation errors of -4.7 ± 25.2 W were obtained when considering VT2dT. Errors were lower than the one-minute power increment of 25 W in 68% of the subjects and lower than 50 W in 89.5% of them. When using VT2LFdT, estimation error was of 15.3 ± 32.4 W. Most of the subjects shared common characteristic dT and LFdT profiles, which could be reflecting changes in the autonomic control of ventricular repolarization before and after reaching VT2. The analysis of ventricular repolarization dynamics during exercise allows non-invasive ECG-based estimation of VT2, possibly in relation to changes in the autonomic control of ventricular electrical activity when VT2 is reached.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Location of parasympathetic innervation regions from electrograms to guide atrial fibrillation ablation therapy: an in silico modeling study

  • Celotto, Chiara
  • Sánchez, Carlos
  • Mountris, Konstantinos A.
  • Laguna, Pablo
  • Pueyo, Esther
The autonomic nervous system (ANS) plays an essential role in the generation and maintenance of cardiac arrhythmias. The cardiac ANS can be divided into its extrinsic and intrinsic components, with the latter being organized in an epicardial neural network of interconnecting axons and clusters of autonomic ganglia called ganglionated plexi (GPs). GP ablation has been associated with a decreased risk of atrial fibrillation (AF) recurrence, but the accurate location of GPs is required for ablation to be effective. Although GP stimulation triggers both sympathetic and parasympathetic ANS branches, a predominance of parasympathetic activity has been shown. This study aims was to develop a method to locate atrial parasympathetic innervation sites based on measurements from a grid of electrograms (EGMs). Electrophysiological models representative of non-AF, paroxysmal AF (PxAF), and persistent AF (PsAF) tissues were developed. Parasympathetic effects were modeled by increasing the concentration of the neurotransmitter acetylcholine (ACh) in randomly distributed circles across the tissue. Different circle sizes of ACh and fibrosis geometries were considered, accounting for both uniform diffuse and non-uniform diffuse fibrosis. Computational simulations were performed, from which unipolar EGMs were computed in a 16 × 1 6 electrode mesh. Different distances of the electrodes to the tissue (0.5, 1, and 2 mm) and noise levels with signal-to-noise ratio (SNR) values of 0, 5, 10, 15, and 20 dB were tested. The amplitude of the atrial EGM repolarization wave was found to be representative of the presence or absence of ACh release sites, with larger positive amplitudes indicating that the electrode was placed over an ACh region. Statistical analysis was performed to identify the optimal thresholds for the identification of ACh sites. In all non-AF, PxAF, and PsAF tissues, the repolarization amplitude rendered successful identification. The algorithm performed better in the absence of fibrosis or when fibrosis was uniformly diffuse, with a mean accuracy of 0.94 in contrast with a mean accuracy of 0.89 for non-uniform diffuse fibrotic cases. The algorithm was robust against noise and worked for the tested ranges of electrode-to-tissue distance. In conclusion, the results from this study support the feasibility to locate atrial parasympathetic innervation sites from the amplitude of repolarization wave.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of Atrial Propagation Patterns and Fibrotic Substrate With a Modified Omnipolar Electrogram Strategy in Multi-Electrode Arrays

  • Riccio, J
  • Alcaine, A
  • Rocher, S
  • Martinez-Mateu, L
  • Laranjo, S
  • Saiz, J
  • Laguna, P
  • Martinez, JP
Introduction: The omnipolar electrogram method was recently proposed to try to generate orientation-independent electrograms. It estimates the electric field from the bipolar electrograms of a clique, under the assumption of locally plane and homogeneous propagation. The local electric field evolution over time describes a loop trajectory from which omnipolar signals in the propagation direction, substrate and propagation features, are derived. In this work, we propose substrate and conduction velocity mapping modalities based on a modified version of the omnipolar electrogram method, which aims to reduce orientation-dependent residual components in the standard approach.</p> & nbsp;</p> Methods: A simulated electrical propagation in 2D, with a tissue including a circular patch of diffuse fibrosis, was used for validation. Unipolar electrograms were calculated in a multi-electrode array, also deriving bipolar electrograms along the two main directions of the grid. Simulated bipolar electrograms were also contaminated with real noise, to assess the robustness of the mapping strategies against noise. The performance of the maps in identifying fibrosis and in reproducing unipolar reference voltage maps was evaluated. Bipolar voltage maps were also considered for performance comparison.</p> & nbsp;</p> Results: Results show that the modified omnipolar mapping strategies are more accurate and robust against noise than bipolar and standard omnipolar maps in fibrosis detection (accuracies higher than 85 vs. 80% and 70%, respectively). They present better correlation with unipolar reference voltage maps than bipolar and original omnipolar maps (Pearson''s correlations higher than 0.75 vs. 0.60 and 0.70, respectively).</p> & nbsp;</p> Conclusion: The modified omnipolar method improves fibrosis detection, characterization of substrate and propagation, also reducing the residual sensitivity to directionality over the standard approach and improving robustness against noise. Nevertheless, studies with real electrograms will elucidate its impact in catheter ablation interventions.</p>
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Nonlinear T-Wave Time Warping-Based Sensing Model for Non-Invasive Personalised Blood Potassium Monitoring in Hemodialysis Patients: A Pilot Study

  • Palmieri, Flavio
  • Gomis, Pedro
  • Ruiz, José Esteban
  • Ferreira, Dina
  • Martín-Yebra, Alba
  • Pueyo, Esther
  • Martínez, Juan Pablo
  • Ramírez, Julia
  • Laguna, Pablo
Background: End-stage renal disease patients undergoing hemodialysis (ESRD-HD) therapy are highly susceptible to malignant ventricular arrhythmias caused by undetected potassium concentration ([K+]) variations (Δ[K+]) out of normal ranges. Therefore, a reliable method for continuous, noninvasive monitoring of [K+] is crucial. The morphology of the T-wave in the electrocardiogram (ECG) reflects Δ[K+] and two time-warping-based T-wave morphological parameters, dw and its heart-rate corrected version dw,c, have been shown to reliably track Δ[K+] from the ECG. The aim of this study is to derive polynomial models relating dw and dw,c with Δ[K+], and to test their ability to reliably sense and quantify Δ[K+] values. Methods: 48-hour Holter ECGs and [K+] values from six blood samples were collected from 29 ESRD-HD patients. For every patient, dw and dw,c were computed, and linear, quadratic, and cubic fitting models were derived from them. Then, Spearman’s (ρ) and Pearson’s (r) correlation coefficients, and the estimation error (ed) between Δ[K+] and the corresponding model-estimated values (Δ^[K+]) were calculated. Results and Discussions: Nonlinear models were the most suitable for Δ[K+] estimation, rendering higher Pearson’s correlation (median 0.77 ≤r≤ 0.92) and smaller estimation error (median 0.20 ≤ed≤ 0.43) than the linear model (median 0.76 ≤r≤ 0.86 and 0.30 ≤ed≤ 0.40), even if similar Spearman’s ρ were found across models (median 0.77 ≤ρ≤ 0.83). Conclusion: Results support the use of nonlinear T-wave-based models as Δ[K+] sensors in ESRD-HD patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Machine learning enables noninvasive prediction of atrial fibrillation driver location and acute pulmonary vein ablation success using the 12-lead ECG

  • Luongo, Giorgio
  • Azzolin, Luca
  • Schuler, Steffen
  • Rivolta, Massimo W.
  • Almeida, Tiago P.
  • Martínez, Juan P.
  • Soriano, Diogo C.
  • Luik, Armin
  • Müller-Edenborn, Björn
  • Jadidi, Amir
  • Dössel, Olaf
  • Sassi, Roberto
  • Laguna, Pablo
  • Loewe, Axel
Background: Atrial fibrillation (AF) is the most common supraventricular arrhythmia, characterized by disorganized atrial electrical activity, maintained by localized arrhythmogenic atrial drivers. Pulmonary vein isolation (PVI) allows to exclude PV-related drivers. However, PVI is less effective in patients with additional extra-PV arrhythmogenic drivers. Objectives: To discriminate whether AF drivers are located near the PVs vs extra-PV regions using the noninvasive 12-lead electrocardiogram (ECG) in a computational and clinical framework, and to computationally predict the acute success of PVI in these cohorts of data. Methods: AF drivers were induced in 2 computerized atrial models and combined with 8 torso models, resulting in 1128 12-lead ECGs (80 ECGs with AF drivers located in the PVs and 1048 in extra-PV areas). A total of 103 features were extracted from the signals. Binary decision tree classifier was trained on the simulated data and evaluated using hold-out cross-validation. The PVs were subsequently isolated in the models to assess PVI success. Finally, the classifier was tested on a clinical dataset (46 patients: 23 PV-dependent AF and 23 with additional extra-PV sources). Results: The classifier yielded 82.6% specificity and 73.9% sensitivity for detecting PV drivers on the clinical data. Consistency analysis on the 46 patients resulted in 93.5% results match. Applying PVI on the simulated AF cases terminated AF in 100% of the cases in the PV class. Conclusion: Machine learning–based classification of 12-lead-ECG allows discrimination between patients with PV drivers vs those with extra-PV drivers of AF. The novel algorithm may aid to identify patients with high acute success rates to PVI.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

QT variability unrelated to RR variability during stress testing for identification of coronary artery disease

  • González del Castillo, Marta
  • Hernando, David
  • Orini, Michele
  • Laguna, Pablo
  • Viik, Jari
  • Bailón, Raquel
  • Pueyo, Esther
Stress test electrocardiogram (ECG) analysis is widely used for coronary artery disease (CAD) diagnosis despite its limited accuracy. Alterations in autonomic modulation of cardiac electrical activity have been reported in CAD patients during acute ischemia. We hypothesized that those alterations could be reflected in changes in ventricular repolarization dynamics during stress testing that could be measured through QT interval variability (QTV). However, QTV is largely dependent on RR interval variability (RRV), which might hinder intrinsic ventricular repolarization dynamics. In this study, we investigated whether different markers accounting for low-frequency (LF) oscillations of QTV unrelated to RRV during stress testing could be used to separate patients with and without CAD. Power spectral density of QTV unrelated to RRV was obtained based on time-frequency coherence estimation. Instantaneous LF power of QTV and QTV unrelated to RRV were obtained. LF power of QTV unrelated to RRV normalized by LF power of QTV was also studied. Stress test ECG of 100 patients were analysed. Patients referred to coronary angiography were classified into non-CAD or CAD group. LF oscillations in QTV did not show significant differences between CAD and non-CAD groups. However, LF oscillations in QTV unrelated to RRV were significantly higher in the CAD group as compared with the non-CAD group when measured during the first phases of exercise and last phases of recovery. ROC analysis of these indices revealed area under the curve values ranging from 61 to 73%. Binomial logistic regression analysis revealed LF power of QTV unrelated to RRV, both during the first phase of exercise and last phase of recovery, as independent predictors of CAD. In conclusion, this study highlights the importance of removing the influence of RRV when measuring QTV during stress testing for CAD identification and supports the added value of LF oscillations of QTV unrelated to RRV to diagnose CAD from the first minutes of exercise. This article is part of the theme issue 'Advanced computation in cardiovascular physiology: new challenges and opportunities'.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG-based monitoring of blood potassium concentration: Periodic versus principal component as lead transformation for biomarker robustness

  • Palmieri, Flavio
  • Gomis, Pedro
  • Ruiz, José Esteban
  • Ferreira, Dina
  • Martín-Yebra, Alba
  • Pueyo, Esther
  • Martínez, Juan Pablo
  • Ramírez, Julia
  • Laguna, Pablo
Objective: The aim of this study is to compare the performance of two electrocardiogram (ECG) lead-space reduction (LSR) techniques in generating a transformed ECG lead from which T-wave morphology markers can be reliably derived to non-invasively monitor blood potassium concentration ([K+]) in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD). These LSR techniques are: (1) principal component analysis (PCA), learned on the T wave, and (2) periodic component analysis (πCA), either learned on the whole QRST complex (πCB) or on the T wave (πCT). We hypothesized πCA is less sensitive to non-periodic disturbances, like noise and body position changes (BPC), than PCA, thus leading to more reliable T wave morphology markers. Methods: We compared the ability of T wave morphology markers obtained from PCA, πCB and πCT in tracking [K+] in an ESRD-HD dataset, including 29 patients, during and after HD (evaluated by correlation and residual fitting error analysis). We also studied their robustness to BPC using an annotated database, including 20 healthy individuals, as well as to different levels of noise using a simulation set-up (assessed by means of Mann–Whitney U test and relative error, respectively). Results: The performance of both πCB and πCT-based markers in following [K+]-variations during HD was comparable, and superior to that from PCA-based markers. Moreover, πCT-based markers showed superior robustness against BPC and noise. Conclusion: Both πCB and πCT outperform PCA in terms of monitoring [K+] in ESRD-HD patients, as well as of robustness against BPC and low SNR, with πCT showing the highest stability for continuous post-HD monitoring. Significance: The usage of πCA (i) increases the accuracy in monitoring dynamic [K+] variations in ESRD-HD patients and (ii) reduces the sensitivity to BPC and noise in deriving T wave morphology markers. © 2021 The Author(s)
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Reseña (Review)

Emerging evidence for a mechanistic link between low-frequency oscillation of ventricular repolarization measured from the electrocardiogram T-wave vector and arrhythmia

  • Taggart, P.
  • Pueyo, E.
  • Van Duijvenboden, S.
  • Porter, B.
  • Bishop, M.
  • Sampedro-Puente, D. A.
  • Orini, M.
  • Hanson, B.
  • Rinaldi, C. A.
  • Gill, J. S.
  • Lambiase, P.
Strong recent clinical evidence links the presence of prominent oscillations of ventricular repolarization in the low-frequency range (0.04-0.15 Hz) to the incidence of ventricular arrhythmia and sudden death in post-MI patients and patients with ischaemic and non-ischaemic cardiomyopathy. It has been proposed that these oscillations reflect oscillations of ventricular action potential duration at the sympathetic nerve frequency. Here we review emerging evidence to support that contention and provide insight into possible underlying mechanisms for this association.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Estimation of potassium levels in hemodialysis patients by T wave nonlinear dynamics and morphology markers

  • Bukhari, Hassaan A.
  • Sánchez, Carlos
  • Srinivasan, Sabarathinam
  • Palmieri, Flavio
  • Potse, Mark
  • Laguna, Pablo
  • Pueyo, Esther
Noninvasive screening of hypo- and hyperkalemia can prevent fatal arrhythmia in end-stage renal disease (ESRD) patients, but current methods for monitoring of serum potassium (K+) have important limitations. We investigated changes in nonlinear dynamics and morphology of the T wave in the electrocardiogram (ECG) of ESRD patients during hemodialysis (HD), assessing their relationship with K+ and designing a K+ estimator. Methods: ECG recordings from twenty-nine ESRD patients undergoing HD were processed. T waves in 2-min windows were extracted at each hour during an HD session as well as at 48 h after HD start. T wave nonlinear dynamics were characterized by two indices related to the maximum Lyapunov exponent (¿t, ¿wt) and a divergence-related index (¿). Morphological variability in the T wave was evaluated by three time warping-based indices (dw, reflecting morphological variability in the time domain, and da and daNL, in the amplitude domain). K+was measured from blood samples extracted during and after HD. Stage-specific and patient-specific K+ estimators were built based on the quantified indices and leave-one-out cross-validation was performed separately for each of the estimators. Results: The analyzed indices showed high inter-individual variability in their relationship with K+. Nevertheless, all of them had higher values at the HD start and 48 h after it, corresponding to the highest K+. The indices ¿ and dw were the most strongly correlated with K+ (median Pearson correlation coefficient of 0.78 and 0.83, respectively) and were used in univariable and multivariable linear K+ estimators. Agreement between actual and estimated K+ was confirmed, with averaged errors over patients and time points being 0.000 ± 0.875 mM and 0.046 ± 0.690 mM for stage-specific and patient-specific multivariable K+ estimators, respectively.ariability allow noninvasive monitoring of [K+] in ESRD patients. Significance: ECG markers have the potential to be used for hypo- and hyperkalemia screening in ESRD patients
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Monitoring of serum potassium and calcium levels in end-stage renal disease patients by ecg depolarization morphology analysis

  • Bukhari, Syed Hassaan Ahmed
  • Sánchez, Carlos
  • Ruiz, José Esteban
  • Potse, Mark
  • Laguna, Pablo
  • Pueyo, Esther
Objective: Non-invasive estimation of serum potassium, [K+], and calcium, [Ca2+], can help to prevent life-threatening ventricular arrhythmias in patients with advanced renal disease, but current methods for estimation of electrolyte levels have limitations. We aimed to develop new markers based on the morphology of the QRS complex of the electrocardiogram (ECG). Methods: ECG recordings from 29 patients undergoing hemodialysis (HD) were processed. Mean warped QRS complexes were computed in two-minute windows at the start of an HD session, at the end of each HD hour and 48 h after it. We quantified QRS width, amplitude and the proposed QRS morphology-based markers that were computed by warping techniques. Reference [K+] and [Ca2+] were determined from blood samples acquired at the time points where the markers were estimated. Linear regression models were used to estimate electrolyte levels from the QRS markers individually and in combination with T wave morphology markers. Leave-one-out cross-validation was used to assess the performance of the estimators. Results: All markers, except for QRS width, strongly correlated with [K+] (median Pearson correlation coefficients, r, ranging from 0.81 to 0.87) and with [Ca2+] (r ranging from 0.61 to 0.76). QRS morphology markers showed very low sensitivity to heart rate (HR). Actual and estimated serum electrolyte levels differed, on average, by less than 0.035 mM (relative error of 0.018) for [K+] and 0.010 mM (relative error of 0.004) for [Ca2+] when patient-specific multivariable estimators combining QRS and T wave markers were used. Conclusion: QRS morphological markers allow non-invasive estimation of [K+] and [Ca2+] with low sensitivity to HR. The estimation performance is improved when multivariable models, including T wave markers, are considered. Significance: Markers based on the QRS complex of the ECG could contribute to non-invasive monitoring of serum electrolyte levels and arrhythmia risk prediction in patients with renal disease
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Strain Echocardiography to Predict Postoperative Atrial Fibrillation

  • Sanchez, Francisco Javier
  • Pueyo, Esther
  • Diez, Emiliano Raúl
Postoperative atrial fibrillation (POAF) complicates 15% to 40% of cardiovascular surgeries. Its incidence progressively increases with aging, reaching 50% in octogenarians. This arrhythmia is usually transient but it increases the risk of embolic stroke, prolonged hospital stay, and cardiovascular mortality. Though many pathophysiological mechanisms are known, POAF prediction is still a hot topic of discussion. Doppler echocardiogram and, lately, strain echocardiography have shown significant capacity to predict POAF. Alterations in oxidative stress, calcium handling, mitochondrial dysfunction, inflammation, fibrosis, and tissue aging are among the mechanisms that predispose patients to the perfect "atrial storm". Manifestations of these mechanisms have been related to enlarged atria and impaired function, which can be detected prior to surgery. Specific alterations in the atrial reservoir and pump function, as well as atrial dyssynchrony determined by echocardiographic atrial strain, can predict POAF and help to shed light on which patients could benefit from preventive therapy.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Analysis of age-related left ventricular collagen remodeling in living donors: Implications in arrhythmogenesis

  • García-Mendívil, Laura
  • Pérez-Zabalza, María
  • Mountris, Konstantinos
  • Duwé, Sam
  • Smisdom, Nick
  • Pérez, Marta
  • Luján, Lluis
  • Wolfs, Esther
  • Driesen, Ronald B.
  • Vallejo-Gil, José María
  • Fresneda-Roldán, Pedro Carlos
  • Fañanás-Mastral, Javier
  • Vázquez-Sancho, Manuel
  • Matamala-Adell, Marta
  • Sorribas-Berjón, Juan Fernando
  • Bellido-Morales, Javier André
  • Mancebón-Sierra, Francisco Javier
  • Vaca-Núñez, Alexander Sebastián
  • Ballester-Cuenca, Carlos
  • Oliván-Viguera, Aida
  • Diez, Emiliano
  • Ordovás, Laura
  • Pueyo, Esther
Age-related fibrosis in the left ventricle (LV) has been mainly studied in animals by assessing collagen content. Using second-harmonic generation microscopy and image processing, we evaluated amount, aggregation and spatial distribution of LV collagen in young to old pigs, and middle-age and elder living donors. All collagen features increased when comparing adult and old pigs with young ones, but not when comparing adult with old pigs or middle-age with elder individuals. Remarkably, all collagen parameters strongly correlated with lipofuscin, a biological age marker, in humans. By building patient-specific models of human ventricular tissue electrophysiology, we confirmed that amount and organization of fibrosis modulated arrhythmia vulnerability, and that distribution should be accounted for arrhythmia risk assessment. In conclusion, we characterize the age-associated changes in LV collagen and its potential implications for ventricular arrhythmia development. Consistency between pig and human results substantiate the pig as a relevant model of age-related LV collagen dynamics. © 2022 The Author(s)
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modelización matemática y simulación computacional de la variabilidad espacio-temporal en la actividad eléctrica cardíaca

  • Pueyo Paules, Esther
The electrical activity of the heart is the result of complex biophysical and biochemical processes occurring at different scales ranging from submicroscopic to macroscopic. The variability arising from these processes has important effects on cardiac function under both physiological and pathological conditions. In this review, mathematical modeling and simulation of cardiac electrical variability at the level of the cell, tissue and whole organ will be reviewed. A set of studies will be presented, which investigate the role that the stochastic gating of ion channels of cardiac cell membranes plays in the generation of electrical voltage variations along time. Also, methodologies for the development, calibration and evaluation of populations of mathematical models able to represent variations in cardiac electrophysiology across space, i.e. among cells, tissues or individuals, will be described. In particular, methods based on state-space representations, dimension reduction techniques and nonlinear adaptive filtering will be presented and their capacity to replicate experimentally measured spatio-temporal variability will be illustrated. The importance of these methodologies will be shown as a means to ascertain the mechanisms underlying variability, to establish the link between variability and cardiac arrhythmias (irregularities in heart beating) and to propose clinical markers for diagnosis, monitoring and treatment of cardiac diseases.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

QT interval Adaptation to Heart Rate Changes in Atrial Fibrillation as a Predictor of Sudden Cardiac Death

  • Martin-Yebra, A.
  • Sornmo, L.
  • Laguna, P.
Objective: The clinical significance of QT interval adaptation to heart rate changes has been poorly investigated in atrial fibrillation (AF), since QT delineation in the presence of f-waves is challenging. Therefore, the objective of the present study is to investigate new techniques for QT adaptation estimation in permanent AF. Methods: A multilead strategy based on generalized periodic component analysis is proposed for QT delineation, involving a spatial, linear transformation which emphasizes Twave periodicity and attenuates f-waves. QT adaptation is modeled by a linear, time-invariant filter, whose impulse response describes the dependence between the current QT interval and the preceding RR intervals, followed by a memoryless, possibly nonlinear, function. The QT adaptation time lag is determined from the estimated impulse response. Results: Using simulated ECGs in permanent AF, the transformed lead was found to offer more accurate QT delineation and time lag estimation than did the original ECG leads for a wide range of f-wave amplitudes (the time lag estimation error was found to be -0.2+/-0.6 s for SNR = 12 dB). In a population with chronic heart failure and permanent AF, the time lag estimated from the transformed lead was found to have the strongest, statistically significant association with sudden cardiac death (SCD) (hazard ratio = 3.49), whereas none of the original, orthogonal leads had any such association. Conclusions: Periodic component analysis provides more accurate QT delineation and improves time lag estimation in AF. A prolonged adaptation time of the QT interval to heart rate changes is associated with a high risk for SCD. Significance: This study demonstrates that SCD risk markers, originally developed for sinus rhythm, can also be used in AF, provided that Twave periodicity is emphasized. The time lag is a potentially useful marker for identifying patients at high risk for SCD, guiding clinicians in adopting effective therapeutic decisions. IEEE
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Dynamical mechanism for generation of arrhythmogenic early afterdepolarizations in cardiac myocytes: insights from in silico electrophysiological models

  • Barrio, R.
  • Martínez, M. A.
  • Serrano, S.
  • Pueyo, E.
We analyze the dynamical mechanisms underlying the formation of arrhythmogenic early afterdepolarizations (EADs) in two mathematical models of cardiac cellular electrophysiology: the Sato et al. biophysically detailed model of a rabbit ventricular myocyte of dimension 27 and a reduced version of the Luo-Rudy mammalian myocyte model of dimension 3. Based on a comparison of the two models, with detailed bifurcation analysis using spike-counting techniques and continuation methods in the simple model and numerical explorations in the complex model, we locate the point where the first EAD originates in an unstable branch of periodic orbits. These results serve as a basis to propose a conjectured scheme involving a hysteresis mechanism with the creation of alternans and EADs in the unstable branch. This theoretical scheme fits well with electrophysiological experimental data on EAD generation and hysteresis phenomena. Our findings open the door to the development of novel methods for pro-arrhythmia risk prediction related to EAD generation without actual induction of EADs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Meshless electrophysiological modeling of cardiac resynchronization therapy—benchmark analysis with finite-element methods in experimental data

  • Albors, C.
  • Lluch, È.
  • Gomez, J. F.
  • Cedilnik, N.
  • Mountris, K. A.
  • Mansi, T.
  • Khamzin, S.
  • Dokuchaev, A.
  • Solovyova, O.
  • Pueyo, E.
  • Sermesant, M.
  • Sebastian, R.
  • Morales, H. G.
  • Camara, O.
Computational models of cardiac electrophysiology are promising tools for reducing the rates of non-response patients suitable for cardiac resynchronization therapy (CRT) by optimizing electrode placement. The majority of computational models in the literature are mesh-based, primarily using the finite element method (FEM). The generation of patient-specific cardiac meshes has traditionally been a tedious task requiring manual intervention and hindering the modeling of a large number of cases. Meshless models can be a valid alternative due to their mesh quality independence. The organization of challenges such as the CRT-EPiggy19, providing unique experimental data as open access, enables benchmarking analysis of different cardiac computational modeling solutions with quantitative metrics. We present a benchmark analysis of a meshless-based method with finite-element methods for the prediction of cardiac electrical patterns in CRT, based on a subset of the CRT-EPiggy19 dataset. A data assimilation strategy was designed to personalize the most relevant parameters of the electrophysiological simulations and identify the optimal CRT lead configuration. The simulation results obtained with the meshless model were equivalent to FEM, with the most relevant aspect for accurate CRT predictions being the parameter personalization strategy (e.g., regional conduction velocity distribution, including the Purkinje system and CRT lead distribution). © 2022 by the authors. Licensee MDPI, Basel, Switzerland.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A dual adaptive explicit time integration algorithm for efficiently solving the cardiac monodomain equation

  • Mountris K.A.
  • Pueyo E.
The monodomain model is widely used in in-silico cardiology to describe excitation propagation in the myocardium. Frequently, operator splitting is used to decouple the stiff reaction term and the diffusion term in the monodomain model so that they can be solved separately. Commonly, the diffusion term is solved implicitly with a large time step while the reaction term is solved by using an explicit method with adaptive time stepping. In this work, we propose a fully explicit method for the solution of the decoupled monodomain model. In contrast to semi-implicit methods, fully explicit methods present lower memory footprint and higher scalability. However, such methods are only conditionally stable. We overcome the conditional stability limitation by proposing a dual adaptive explicit method in which adaptive time integration is applied for the solution of both the reaction and diffusion terms. We perform a set of numerical examples where cardiac propagation is simulated under physiological and pathophysiological conditions. Results show that the proposed method presents preserved accuracy and improved computational efficiency as compared to standard operator splitting-based methods. © 2021 John Wiley & Sons Ltd.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Fabrication of human myocardium using multidimensional modelling of engineered tissues

  • Montero-Calle, Pilar
  • Flandes-Iparraguirre, María
  • Mountris, Konstantinos
  • S de la Nava, Ana
  • Laita, Nicolás
  • Rosales, Ricardo M
  • Iglesias-García, Olalla
  • de-Juan-Pardo, Elena M
  • Atienza, Felipe
  • Fernández-Santos, María Eugenia
  • Peña, Estefanía
  • Doblaré, Manuel
  • Gavira, Juan J
  • Fernández-Avilés, Francisco
  • Prósper, Felipe
  • Pueyo, Esther
  • Mazo, Manuel M
Biofabrication of human tissues has seen a meteoric growth triggered by recent technical advancements such as human induced pluripotent stem cells (hiPSCs) and additive manufacturing. However, generation of cardiac tissue is still hampered by lack of adequate mechanical properties and crucially by the often unpredictable post-fabrication evolution of biological components. In this study we employ melt electrowriting (MEW) and hiPSC-derived cardiac cells to generate fibre-reinforced human cardiac minitissues. These are thoroughly characterized in order to build computational models and simulations able to predict their post-fabrication evolution. Our results show that MEW-based human minitissues display advanced maturation 28 post-generation, with a significant increase in the expression of cardiac genes such as MYL2, GJA5, SCN5A and the MYH7/MYH6 and MYL2/MYL7 ratios. Human iPSC-cardiomyocytes are significantly more aligned within the MEW-based 3D tissues, as compared to conventional 2D controls, and also display greater expression of C ×43. These are also correlated with a more mature functionality in the form of faster conduction velocity. We used these data to develop simulations capable of accurately reproducing the experimental performance. In-depth gauging of the structural disposition (cellular alignment) and intercellular connectivity (C ×43) allowed us to develop an improved computational model able to predict the relationship between cardiac cell alignment and functional performance. This study lays down the path for advancing in the development of in silico tools to predict cardiac biofabricated tissue evolution after generation, and maps the route towards more accurate and biomimetic tissue manufacture.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiac cells stimulated with an axial current-like waveform reproduce electrophysiological properties of tissue fibers

  • Monasterio, Violeta
  • Pueyo, Esther
  • Rodríguez-Matas, José Félix
  • Carro, Jesús
Background and objective: In silico electrophysiological models are generally validated by comparing simulated results with experimental data. When dealing with single-cell and tissue scales simultaneously, as occurs frequently during model development and calibration, the effects of inter-cellular coupling should be considered to ensure the trustworthiness of model predictions. The hypothesis of this paper is that the cell-tissue mismatch can be reduced by incorporating the effects of conduction into the single-cell stimulation current. Methods: Five different stimulation waveforms were applied to the human ventricular O'Hara-Rudy cell model. The waveforms included the commonly used monophasic and biphasic (symmetric and asymmetric) pulses, a triangular waveform and a newly proposed asymmetric waveform (stimulation A) that resembles the transmembrane current associated with AP conduction in tissue. A comparison between single-cell and fiber simulated results was established by computing the relative difference between the values of AP-derived properties at different scales, and by evaluating the differences in the contributions of ionic conductances to each evaluated property. As a proof of the benefit, we investigated multi-scale differences in the simulation of the effects induced by dofetilide, a selective IKr blocker with high torsadogenic risk, on ventricular repolarization at different pacing rates. Results: Out of the five tested stimulation waveforms, stimulation A produced the closest correspondence between cell and tissue simulations in terms of AP properties at steady-state and under dynamic pacing and of ionic contributors to those AP properties. Also, stimulation A reproduced the effects of dofetilide better than the other alternative waveforms, mirroring the ’beat-skipping’ behavior observed at fast pacing rates in experiments with human tissue. Conclusions: The proposed stimulation current waveform accounts for inter-cellular coupling effects by mimicking cell excitation during AP conduction. The proposed waveform improves the correspondence between simulation scales, which could improve the trustworthiness of single-cell simulations without adding computational cost. © 2022
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Spectral Analysis of Heart Rate Variability in Time-Varying Conditions and in the Presence of Confounding Factors

  • Sornmo, Leif
  • Bailon, Raquel
  • Laguna, Pablo
The tools for spectrally analyzing heart rate variability (HRV) has in recent years grown considerably, with emphasis on the handling of time-varying conditions and confounding factors. Time–frequency analysis holds since long an important position in HRV analysis, however, this technique cannot alone handle a mean heart rate or a respiratory frequency which vary over time. Overlapping frequency bands represents another critical condition which needs to be dealt with to produce accurate spectral measurements. The present survey offers a comprehensive account of techniques designed to handle such conditions and factors by providing a brief description of the main principles of the different methods. Several methods derive from a mathematical/statistical model, suggesting that the model can be used to simulate data used for performance evaluation. The inclusion of a respiratory signal, whether measured or derived, is another feature of many recent methods, e.g., used to guide the decomposition of the HRV signal so that signals related as well as unrelated to respiration can be analyzed. It is concluded that the development of new approaches to handling time-varying scenarios are warranted, as is benchmarking of performance evaluated in technical as well as in physiological/clinical terms.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Physical activity in centenarians beyond cut-point-based accelerometer metrics

  • Hernández-Vicente, A.
  • Marín Puyalto, J.
  • Pueyo, E.
  • Vicente Rodríguez, G.
  • Garatachea, N.
This study described and compared physical activity (PA) characteristics at the end of the human lifespan using conventional cut-point-based versus cut-point-free accelerometer metrics. Eighteen institutionalized centenarians (101.5 ± 2.1 years, 72.2% female, 89% frail) wore the wrist GENEActiv accelerometer for 7 days. Conventional metrics, such as time spent in light-intensity PA (LiPA) and moderate-to-vigorous intensity PA (MVPA) were calculated according to published cut-points for adults and older adults. The following cut-point-free metrics were evaluated: average acceleration, intensity gradient and Mx metrics. Depending on the cut-point, centenarians accumulated a median of 15–132 min/day of LiPA and 3–15 min/day of MVPA. The average acceleration was 9.2 mg [Q1: 6.7 mg–Q3: 12.6 mg] and the intensity gradient was −3.19 [−3.34–−3.12]. The distribution of Z-values revealed positive skew for MVPA, indicating a potential floor effect, whereas the skew magnitude was attenuated for cut-point-free metrics such as intensity gradient or M5. However, both cut-point-based and cut-point-free metrics were similarly positively associated with functional independence, cognitive and physical capacities. This is the first time that PA has been described in centenarians using cut-point-free metrics. Our results suggest that new analytical approaches could overcome cut-point limitations when studying the oldest-old. Future studies using these new cut-point-free PA metrics are warranted to provide more complete and comparable information across groups and populations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Atrial fibrosis identification with unipolar electrogram eigenvalue distribution analysis in multi-electrode arrays

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher, Sara
  • Martinez-Mateu, Laura
  • Saiz, Javier
  • Invers-Rubio, Eric
  • Guillem, Maria S.
  • Martínez, Juan Pablo
  • Laguna, Pablo
Atrial fbrosis plays a key role in the initiation and progression of atrial fbrillation (AF). Atrial fbrosis is typically identifed by a peak-to-peak amplitude of bipolar electrograms (b-EGMs) lower than 0.5 mV, which may be considered as ablation targets. Nevertheless, this approach disregards signal spatiotemporal information and b-EGM sensitivity to catheter orientation. To overcome these limitations, we propose the dominant-to-remaining eigenvalue dominance ratio (EIGDR) of unipolar electrograms (u-EGMs) within neighbor electrode cliques as a waveform dispersion measure, hypothesizing that it is correlated with the presence of fbrosis. A simulated 2D tissue with a fbrosis patch was used for validation. We computed EIGDR maps from both original and time-aligned u-EGMs, denoted as R and RA, respectively, also mapping the gain in eigenvalue concentration obtained by the alignment, ΔRA. The performance of each map in detecting fbrosis was evaluated in scenarios including noise and variable electrode-tissue distance. Best results were achieved by RA, reaching 94% detection accuracy, versus the 86% of b-EGMs voltage maps. The proposed strategy was also tested in real u-EGMs from fbrotic and non-fbrotic areas over 3D electroanatomical maps, supporting the ability of the EIGDRs as fbrosis markers, encouraging further studies to confrm their translation to clinical settings.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A meshless fragile points method for rule-based definition of myocardial fiber orientation

  • Mountris, Konstantinos A.
  • Pueyo, Esther
Background and objective: Rule-based methods are commonly used to estimate the arrangement of myocardial fibers by solving the Laplace problem with appropriate Dirichlet boundary conditions. Existing algorithms are using the Finite Element Method (FEM) to solve the Laplace–Dirichlet problem. However, meshless methods are under development for cardiac electrophysiology simulation. The objective of this work is to propose a meshless rule based method for the determination of myocardial fiber arrangement without requiring a mesh discretization as it is required by FEM. Methods: The proposed method employs the Fragile Points Method (FPM) for the solution of the Laplace–Dirichlet problem. FPM uses simple discontinuous trial functions and single-point exact integration for linear trial functions that set it as a promising alternative to the Finite Element Method. We derive the FPM formulation of the Laplace–Dirichlet and we estimate ventricular and atrial fiber arrangements according to rules based on histology findings for four different geometries. The obtained fiber arrangements from FPM are compared with the ones obtained from FEM by calculating the angle between the fiber vector fields of the two methods for three different directions (i.e., longitudinal, sheet, transverse). Results:The fiber arrangements that were generated with FPM were in close agreement with the generated arrangements from FEM for all three directions. The mean angle difference between the FPM and FEM vector fields were lower than for the ventricular fiber arrangements and lower than for the atrial fiber arrangements. Discussion:The proposed meshless rule-based method was proven to generate myocardial fiber arrangements with very close agreement with FEM while alleviates the requirement for a mesh of the latter. This is of great value for cardiac electrophysiology solvers that are based on meshless methods since they require a well defined myocardial fiber arrangement to simulate accurately the propagation of electrical signals in the heart. Combining a meshless solution for both the determination of the fibers and the electrical signal propagation can allow for solution that do not require the definition of a mesh. To our knowledge, this work is the first one to propose a meshless rule-based method for myocardial fiber arrangement determination.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Deep-Learning-Based Estimation of the Spatial QRS-T Angle from Reduced-Lead ECGs

  • Santos Rodrigues, Ana
  • Augustauskas, Rytis
  • Lukosevicius, Mantas
  • Laguna, Pablo
  • Marozas, Vaidotas
The spatial QRS-T angle is a promising health indicator for risk stratification of sudden cardiac death (SCD). Thus far, the angle is estimated solely from 12-lead electrocardiogram (ECG) systems uncomfortable for ambulatory monitoring. Methods to estimate QRS-T angles from reduced-lead ECGs registered with consumer healthcare devices would, therefore, facilitate ambulatory monitoring. (1) Objective: Develop a method to estimate spatial QRS-T angles from reduced-lead ECGs. (2) Approach: We designed a deep learning model to locate the QRS and T wave vectors necessary for computing the QRS-T angle. We implemented an original loss function to guide the model in the 3D space to search for each vector''s coordinates. A gradual reduction of ECG leads from the largest publicly available dataset of clinical 12-lead ECG recordings (PTB-XL) is used for training and validation. (3) Results: The spatial QRS-T angle can be estimated from leads {I, II, aVF, V2} with sufficient accuracy (absolute mean and median errors of 11.4 degrees and 7.3 degrees) for detecting abnormal angles without sacrificing patient comfortability. (4) Significance: Our model could enable ambulatory monitoring of spatial QRS-T angles using patch- or textile-based ECG devices. Populations at risk of SCD, like chronic cardiac and kidney disease patients, might benefit from this technology.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The role of ß-adrenergic stimulation in QT interval adaptation to heart rate during stress test

  • Pérez, Cristina
  • Cebollada, Rubén
  • Mountris, Konstantinos A.
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Pueyo, Esther
The adaptation lag of the QT interval after heart rate (HR) has been proposed as an arrhythmic risk marker. Most studies have quantified the QT adaptation lag in response to abrupt, step-like changes in HR induced by atrial pacing, in response to tilt test or during ambulatory recordings. Recent studies have introduced novel methods to quantify the QT adaptation lag to gradual, ramp-like HR changes in stress tests by evaluating the differences between the measured QT series and an estimated, memoryless QT series obtained from the instantaneous HR. These studies have observed the QT adaptation lag to progressively reduce when approaching the stress peak, with the underlying mechanisms being still unclear. This study analyzes the contribution of β-adrenergic stimulation to QT interval rate adaptation in response to gradual, ramp-like HR changes. We first quantify the QT adaptation lag in Coronary Artery Disease (CAD) patients undergoing stress test. To uncover the involved mechanisms, we use biophysically detailed computational models coupling descriptions of human ventricular electrophysiology and β-adrenergic signaling, from which we simulate ventricular action potentials and ECG signals. We characterize the adaptation of the simulated QT interval in response to the HR time series measured from each of the analyzed CAD patients. We show that, when the simulated ventricular tissue is subjected to a time-varying β-adrenergic stimulation pattern, with higher stimulation levels close to the stress peak, the simulated QT interval presents adaptation lags during exercise that are more similar to those measured from the patients than when subjected to constant β-adrenergic stimulation. During stress test recovery, constant and time-varying β-adrenergic stimulation patterns render similar adaptation lags, which are generally shorter than during exercise, in agreement with results from the patients. In conclusion, our findings support the role of time-varying β-adrenergic stimulation in contributing to QT interval adaptation to gradually increasing HR changes as those seen during the exercise phase of a stress test.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Prevention of sudden death in sports: a global and multidisciplinary Observatory for Scientific Research and Knowledge Transfer (PREMUBID)

  • Garatachea, Nuria
  • Pueyo, Esther
  • Eijsvogels, Thijs M.H.
Background: The health benefits of sports and exercise training are well known. However, an acute bout of exercise transiently increases the risk of sudden cardiac death (SCD). To minimize the cardiovascular risks of exercise, more insight into the prevention and causes of SCD is needed. Methods: The observatory for the prevention of sudden death in sports, PREMUBID, was created with the aim of fostering research to assess the benefits and risks of exercise at different volumes and intensities and to get insight into the underlying mechanisms of potentially cardiac (mal) adaptations. Results: The observatory gathers researchers from a wide range of disciplines working at institutions in Europe and North America. The guiding principles of PREMUBID are to broaden the understanding of SCD in sports, strengthening collaborative research across the globe, and to develop, implement and evaluate robust pre-participation screening and emergency care strategies to further reduce the number of fatal cardiac events in sport events. During the inaugural meeting of the observatory, members and affiliated researchers discussed possibilities to initiate collaborative research projects and to exchange staff and students to share information and practices to prevent SCD. The final goal is to translate the obtained knowledge to understandable messages for the general population and healthcare workers to ensure that the population at large benefits from it. Conclusions: The PREMUBID consortium aims to produce novel knowledge and insights in SCD prevention, in order to maximize the health benefits associated with acute and long-term exercise training.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Steady-state and transient effects of SK channel block and adrenergic stimulation to counteract acetylcholine-induced arrhythmogenic effects in the human atria: a computational study

  • Celotto, Ch.
  • Sánchez, C.
  • Mountris, K. A.
  • Laguna, P.
  • Pueyo, E.
Hyperactivity of the parasympathetic nervous system has been linked to the development of paroxysmal atrial fibrillation (AF). The parasympathetic neurotransmitter acetylcholine (ACh) causes a reduction in action potential (AP) duration (APD) and an increase in resting membrane potential (RMP), both of which contribute to enhance the risk for reentry. Research suggests that small-conductance calcium activated potassium (SK) channels may be an effective target for treating AF. Therapies targeting the autonomic nervous system, either alone or in combination with other drugs, have been explored and have been shown to decrease the incidence of atrial arrhythmias. This study uses computational modeling and simulation to examine the impact of SK channel block (SKb) and-adrenergic stimulation through Isoproterenol (Iso) on countering the negative effects of cholinergic activity in human atrial cell and 2D tissue models. The steady-state effects of Iso and/or SKb on AP shape, APD at 90% repolarization (APD90) and RMP were evaluated. The ability to terminate stable rotational activity in cholinergically-stimulated 2D tissue models of AF was also investigated. A range of SKb and Iso application kinetics, which reflect varying drug binding rates, were taken into consideration. The results showed that SKb alone prolonged APD90 and was able to stop sustained rotors in the presence of ACh concentrations up to 0.01 M. Iso terminated rotors under all tested ACh concentrations, but resulted in highly-variable steady-state outcomes depending on baseline AP morphology. Importantly, the combination of SKb and Iso resulted in greater APD90 prolongation and showed promising anti-arrhythmic potential by stopping stable rotors and preventing re-inducibility.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Towards advanced cardiac miRNA therapies through DNA-based nanostructures

  • Hernandez-Bellido, N.
  • Postigo, A.
  • Orrite, C.
  • Garrido-Huescar, E.
  • Garcia-Mendivil, L.
  • Pueyo, E.
  • Hernandez-Ainsa, S.
  • Ordovas, L.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Endothelin-1 amplifies ventricular repolarization heterogeneities in chronic myocardial infarction pigs

  • Oliván-Viguera, A.
  • Pérez-Martínez, A.
  • Pueyo, E.
Introduction: Endothelin-1 (ET-1) is a vasoconstrictor peptide secreted by endothelial cells and cardiac myocytes and fibroblasts. It is involved in oxidative stress, apoptosis regulation and ventricular remodeling processes associated with heart failure and ischemic cardiomyopathy, including myocardial hypertrophy, fibrosis and impaired conduction. ET-1 has been shown to influence cardiac electrophysiology by modulation of calcium and potassium currents and to contribute to arrhythmogenesis and sudden cardiac death. Purpose: We aim to characterize the functional role of ET-1 in the electrophysiology of healed myocardial infarction (MI) by analysis of porcine ventricular slices as a highly representative model of ventricular tissue with preserved cellular cross-talks and architecture. Methods: Domestic pigs (60–80 kg, n = 3) were infarcted by temporal occlusion of the left anterior descending coronary artery. 8-12 weeks after infarct induction, animals were cardioplegically arrested under deep anesthesia and sacrificed. All animal procedures conformed to the guidelines from Directive 2010/63/EU and were approved by local authorities. 350 µm-thick ventricular slices were produced from transmural tissue blocks of healed MI ventricles. Tissue blocks were taken from remote, adjacent and border zones of the infarct area. Slices were optically mapped within 8 hours after tissue collection to record transmembrane potential and intracellular calcium. Action Potential Duration (APD) and Calcium Transient Duration (CaTD) were measured at 80% repolarization for 0.5, 1 and 2 Hz pacing frequencies in the presence and absence of 100 nM ET-1. The notation n/N is used to denote n tissue slices from N pigs. Results: ET-1 prolonged the APD at all frequencies in remote zones, with mean prolongation percentages of 30.5%, 32%, 26.2% at 0.5, 1 and 2 Hz, respectively, n/N=7/3. However, only minor effects were observed in adjacent (mean APD prolongation of 3.3%, 4.9% and 10.7%, n/N=5/3) and border zones (7%, 4% and 3.6%, n/N=5/3). ET-1 caused an increase in CaTD at 1 Hz in the three zones, with no significant regional differences in the amount of CaTD increase: mean prolongation of 14.1% (n/N=7/3) in the remote zone, 12.4 % (n/N=5/3) in the adjacent zone and 20.9% (n/N=4/3) in the border zone. Conclusions: In chronic MI pigs, ET-1 induces strong APD and moderate CaTD prolongation of remote normal myocardium at low (0.5 Hz) to high (2 Hz) frequencies. The ET-1-induced effects on the AP of normal tissue, but not on CaT, are disrupted in the border zones of the infarct area and in its proximity. Our results point to ET-1 acting to enhance ventricular repolarization dispersion in chronic MI pigs, which might contribute to increased arrhythmia vulnerability.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Improving signal stability in a multi-electrode array (MEA) system for cardiac biopsies

  • Velarte, A.
  • Otín, A.
  • Pueyo, E.
  • Guimera, A.
  • Villa, R.
This work evaluates the performance of a microelectrode array (MEA) to be used in a specific platform dedicated for measuring field potentials of small human cardiac samples. A test bench has been developed to characterize the electrodes by measuring their impedance as well as to modify their characteristic curve using a replatinization process, where black platinum is deposited on the indicated areas of the MEA flex-pcb. This set-up consists of the array of microelectrodes made of gold, together with its corresponding electronic adapter board, a potentiostat and an electrochemical interface. Phosphate buffered saline (PBS), which is commonly considered for this type of analysis, has been used for impedance characterization. Initially, the impedance presents a highly variable behavior at different frequencies as well as between the different channels of the array. Once the platinization process has been carried out, the impedance in all the recording channels is very similar and has decreased over a large part of the frequency range under study. A complete electrical model of the electrodes has been proposed and analyzed, achieving better results by including the mathematical constant phase element (CPE) associated with capacitive behavior (model fitting error < 2%). Finally, the characterization of the different noise contributions has been carried out. Based on the obtained results, it can be concluded that the evaluated system allows the recording of field potential signals from small human cardiac tissues.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

QT interval time lag in response to heart rate changes during stress test for Coronary Artery Disease diagnosis

  • Pérez, Cristina
  • Pueyo, Esther
  • Martínez, Juan Pablo
  • Viik, Jari
  • Laguna, Pablo
Background: Slow adaptation of the QT interval to abrupt changes in heart rate (HR) can enhance ventricular heterogeneity and has been suggested as a marker of arrhythmic risk. Most investigations on QT rate adaptation lag have been performed in response to step-like HR changes. However, abrupt HR changes are difficult to induce or observe in ECG recordings under ambulatory conditions. Objective: We aim to evaluate the power of indices related to the QT lag in response to ramp-like HR changes in stress test to assess CAD risk. Methods: We quantified the lag between the actual QT series and the memoryless expected QT series, which was obtained by fitting a hyperbolic regression model to the instantaneous QT and HR measurements in stages where their behavior could be assumed stationary. The proposed methodology was applied to analyze ECG stress tests of a subset of 448 patients presenting different risk levels for Coronary Artery Disease (CAD). The QT lag was estimated separately in the exercise and recovery phases. Results: An increase in the estimated QT lag during exercise (from 25 to 36 s) and a decrease during recovery (from 57 to 39 s) were associated with higher CAD risk. The difference between these lags showed significant capacity for CAD risk stratification. Conclusion: The QT lag in response to HR changes can be quantified from a stress test. QT lag values in response to ramp-like HR changes are in ranges comparable to those quantified from abrupt HR changes and show clinical significance to stratify CAD risk.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Fiber-Optic-Based System for High-Resolution Monitoring of Stretch in Excised Tissues

  • Velarte, Antonio
  • Otin, Aranzazu
  • Giménez-Gómez, Pablo
  • Muñoz-Berbel, Xavier
  • Pueyo, Esther
Cardiovascular diseases cause a high number of deaths nowadays. To improve these statistics, new strategies to better understand the electrical and mechanical abnormalities underlying them are urgently required. This study focuses on the development of a sensor to measure tissue stretch in excised tissues, enabling improved knowledge of biomechanical properties and allowing greater control in real time. A system made of biocompatible materials is described, which is based on two cantilevered platforms that integrate an optical fiber inside them to quantify the amount of stretch the tissues are exposed to with a precision of μm. The operating principle of the sensor is based on the variation of the optical path with the movement of the platforms onto which the samples are fixed. The conducted tests highlight that this system, based on a simple topology and technology, is capable of achieving the desired purpose (a resolution of ∼1 μm), enabling the tissue to be bathed in any medium within the system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG modeling for simulation of arrhythmias in time-varying conditions

  • Bachi, Lorenzo
  • Halvaei, Hesam
  • Pérez, Cristina
  • Martín-Yebra, Alba
  • Petrenas, Andrius
  • Sološenko, Andrius
  • Johnson, Linda
  • Marozas, Vaidotas
  • Martínez, Juan Pablo
  • Pueyo, Esther
  • Stridh, Martin
  • Laguna, Pablo
  • Sörnmo, Leif
The present paper proposes an ECG simulator that advances modeling of arrhythmias and noise by introducing time-varying signal characteristics. The simulator is built around a discrete-time Markov chain model for simulating atrial and ventricular arrhythmias of particular relevance when analyzing atrial fibrillation (AF). Each state is associated with statistical information on episode duration and heartbeat characteristics. Statistical, time-varying modeling of muscle noise, motion artifacts, and the influence of respiration is introduced to increase the complexity of simulated ECGs, making the simulator well suited for data augmentation in machine learning. Modeling of how the PQ and QT intervals depend on heart rate is also introduced. The realism of simulated ECGs is assessed by three experienced doctors, showing that simulated ECGs are difficult to distinguish from real ECGs. Simulator usefulness is illustrated in terms of AF detection performance when either simulated or real ECGs are used to train a neural network for signal quality control. The results show that both types of training lead to similar performance.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A Flexible PDMS-Based Optical Biosensor for Stretch Monitoring in Cardiac Tissue Samples

  • Sannino, Andrea
  • Velarte, Antonio
  • Otín, Aránzazu
  • Artigas, José Ignacio
  • Oliván-Viguera, Aida
Cardiotoxicity, characterized by adverse impacts on normal heart function due to drug exposure, is a significant concern due to the potentially serious side effects associated with various pharmaceuticals. It is essential to detect the cardiotoxicity of a drug as early as possible in the testing phase of a medical composite. Therefore, there is a pressing need for more reliable in vitro models that accurately mimic the in vivo conditions of cardiac biopsies. In a functional beating heart, cardiac muscle cells are under the effect of static and cyclic stretches. It has been demonstrated that cultured cardiac biopsies can benefit from external mechanical loads that resemble the in vivo condition, increasing the probability of cardiotoxicity detection in the early testing stages. In this work, a biosensor is designed and fabricated to allow for stretch monitoring in biopsies and tissue cultures using an innovative sensing mechanism. The detection setup is based on a biocompatible, thin, flexible membrane—where the samples are attached—which is used as an optical waveguide to detect pressure-caused shape changes and stretches. Various prototypes have been fabricated with a cost-effective process, and different measurements have been carried out to experimentally validate the proposed measurement technique. From these evaluations, stretches of up to 1.5% have been measured, but the performed simulations point towards the possibility of expanding the considered technique up to 10–30% stretches.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiac electrophysiology meshfree modeling through the mixed collocation method

  • Mountris, Konstantinos A.
  • Pueyo, Esther
We present the meshfree mixed collocation method (MCM) for cardiac electrophysiology simulation. Capitalizing on the meshfree property of MCM, we introduce an immersed grid approach for automated generation of meshfree node grids from medical image data. This approach allows us to avoid the time-consuming mesh generation and processing that mesh-based methods like the finite element method (FEM) require. We employ the MCM to solve the cardiac monodomain model considering electrical propagation in 2D tissue sheets, 3D tissue slabs, and a realistic biventricular anatomy. We demonstrate that the solutions obtained by the MCM are in good agreement with the FEM, particularly when immersed grid is used. These findings confirm the suitability of the MCM for cardiac electrophysiology simulation and make the MCM a promising alternative to the FEM for cardiac electrical investigations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Right ventricular vs left bundle branch pacing-induced changes in ECG depolarization and repolarization

  • Sales Bellés, Clara
  • Palacios, Saúl
  • Melero, Jorge
  • Julián, Inés
  • Ramos, Javier
  • Pablo Martínez, Juan
  • Minchole, Ana
  • Pueyo, Esther
Patients suffering from bradycardia are indicated for pacemaker implantation. Right ventricular pacing (RVP)has been conventionally used for this purpose, but it can increase the risk of atrial fibrillation and heart failure. Left bundle branch area pacing (LBBAP) has been proposed as a new physiological pacing technique. The aim of this study was to compare changes induced by RVP and LBBAP in the ECG. 10-minute 12-lead ECG recordings were acquired at baseline and after pacemaker implantation from 83 patients (31 RVP, 52 LBBAP). Median beats were calculated for each patient at baseline and post-implantation states. ECG markers including QRS duration (dQRS)and area (aQRS) and heart rate-corrected QT (QTc) and Tpeak-to-Tend (Tpec) intervals were measured. dQRS and aQRS decreased significantly at post-implantation with respect to baseline, both being significantly lower for LBBAP than RVP after pacemaker implantation. QTc was significantly reduced at post-implantation for both pacing techniques with no differences between them. Tpec did not change either between states or techniques. In conclusion, LBBAP led to more synchronized ventricular depolarization, supporting potentially improved clinical outcomes with LBBAP as compared to RVP for anti-bradycardia therapy
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Order in chaos: Structure of chaotic invariant sets of square-wave neuron models

  • Serrano, Sergio
  • Martínez, M. Ángeles
  • Barrio, Roberto
Bursting phenomena and, in particular, square-wave or fold/hom bursting, are found in a wide variety of mathematical neuron models. These systems have different behavior regimes depending on the parameters, whether spiking, bursting, or chaotic. We study the topological structure of chaotic invariant sets present in square-wave bursting neuron models, first detailed using the Hindmarsh–Rose neuron model and later exemplary in the more realistic model of a leech heart neuron. We show that the unstable periodic orbits that form the skeleton of the chaotic invariant sets are deeply related to the spike-adding phenomena, typical from these models, and how there are specific symbolic sequences and a symbolic grammar that organize how and where the periodic orbits appear. Linking this information with the topological template analysis permits us to understand how the internal structure of the chaotic invariants is modified and how more symbolic sequences are allowed. Furthermore, the results allow us to conjecture that, for these systems, the limit template when the small parameter ¿, which controls the slow gating variable, tends to zero is the complete Smale topological template.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Classification of fold/hom and fold/Hopf spike-adding phenomena

  • Barrio R.
  • Ibáñez S.
  • Pérez L.
  • Serrano S.
The Hindmarsh-Rose neural model is widely accepted as an important prototype for fold/hom and fold/Hopf burstings. In this paper, we are interested in the mechanisms for the production of extra spikes in a burst, and we show the whole parametric panorama in an unified way. In the fold/hom case, two types are distinguished: a continuous one, where the bursting periodic orbit goes through bifurcations but persists along the whole process and a discontinuous one, where the transition is abrupt and happens after a sequence of chaotic events. In the former case, we speak about canard-induced spike-adding and in the second one, about chaos-induced spike-adding. For fold/Hopf bursting, a single (and continuous) mechanism is distinguished. Separately, all these mechanisms are presented, to some extent, in the literature. However, our full perspective allows us to construct a spike-adding map and, more significantly, to understand the dynamics exhibited when borders are crossed, that is, transitions between types of processes, a crucial point not previously studied. © 2021 Author(s).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

QRS-T angles as markers for heart sphericity in subjects with intrauterine growth restriction: a simulation study

  • Bueno-Palomeque, Freddy L.
  • Mountris, Konstantinos A.
  • Ortigosa, Nuria
  • Bailón, Raquel
  • Bijnens, Bart
  • Crispi, Fàtima
  • Pueyo, Esther
  • Mincholé, Ana
  • Laguna, Pablo
Changes induced by intrauterine growth restriction (IUGR) in cardiovascular anatomy and function that persist throughout life have been associated with a higher predisposition to heart disease in adulthood. Together with cardiac morphological remodelling, evaluated through the ventricular sphericity index, alterations in cardiac electrical function have been reported by characterization of the depolarization and repolarization loops, and their angular relationship, measured from the vectorcardiogram. The underlying relationship between the morphological remodelling and the angular variation of QRS and T-wave dominant vectors, if any, has not been explored. The aim of this study was to evaluate this relationship using computational models based on realistic heart and torso in which IUGR-induced morphological changes were incorporated by reducing the ventricular sphericity index. Specifically, we departed from a control model and we built eight different globular heart models by reducing the base-to-apex length and enlarging the basal ventricular diameter. We computed QRS and T-wave dominant vectors and angles from simulated pseudo-electrocardiograms and we compared them with clinical measurements. Results for the QRS to T angles follow a change trend congruent with that reported in clinical data, supporting the hypothesis that the IUGR-induced morphological remodelling could contribute to explain the observed angle changes in IUGR patients. By additionally varying the position of the ventricles with respect to the torso and the electrodes, we found that electrode displacement can impact the quantified angles and should be considered when interpreting the results.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Time-warping analysis of the T-wave peak-to-end Interval to quantify ventricular repolarization dispersion during ischemia

  • Gómez, Neurys
  • Ramírez, Julia
  • Martínez, Juan Pablo
  • Laguna, Pablo
Variations in the dispersion of ventricular repolarization can be quantified by T-wave time-warping based index, dw . However, the early phase of the T-wave can be affected by ST-segment changes during ischemia. We hypothesized that restricting dw to the T-wave peak-to-end ( Tpe ) would circumvent this limitation while still quantifying variations in repolarization dispersion. A total of 101 ECG recordings from patients undergoing coronary occlusion, together with their control recordings, were analyzed. A series of dw values was calculated by quantifying the Tpe morphological variations between the T-waves at different occlusion stages and a baseline T-wave. We introduced a normalized version of dw , Rd , reflecting variations of dw during occlusion relative to control recordings ( Rd=1 corresponds to the same level of variation). The dw series followed a gradually increasing trend with occlusion time, reaching median [range] Rd values of 9.44 [1.01, 80.74] at the occlusion end. Rd at occlusion end was significantly higher than threshold values of 1, 2, 5, and 10 in 94.1%, 85.11%, 64.4% and 48.5% of patients, respectively. The spatial lead-wise analysis of dw showed distinct distributions depending on the occluded artery, suggesting a relation with the ischemia location. The relative variation R with ischemia of index dw (9.4) is greater than that of the T-wave amplitude (7.7), Tpe interval (2.7) and T-wave width (3.0). In conclusion, dw tracks ischemic-induced variations in repolarization dispersion in a more robust manner than classical indexes, avoiding the impact of ST segment elevation/depression or early T-wave distortions, thus warranting further clinical studies.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Interindividual Age-Independent Differences in Human CX43 Impact Ventricular Arrhythmic Risk

  • García-Mendívil, Laura
  • Pérez-Zabalza, María
  • Oliver-Gelabert, Antoni
  • Vallejo-Gil, José María
  • Fañanás-Mastral, Javier
  • Vázquez-Sancho, Manuel
  • Bellido-Morales, Javier André
  • Vaca-Núñez, Alexánder Sebastián
  • Ballester-Cuenca, Carlos
  • Diez, Emiliano
  • Ordovás, Laura
  • Pueyo, Esther
Connexin 43 (CX43) is one of the major components of gap junctions, the structures responsible for the intercellular communication and transmission of the electrical impulse in the left ventricle. There is limited information on the histological changes of CX43 with age and their effect on electrophysiology, especially in humans. Here, we analyzed left ventricular biopsies from living donors starting at midlife to characterize age-related CX43 remodeling. We assessed its quantity, degree of lateralization, and spatial heterogeneity together with fibrotic deposition. We observed no significant age-related remodeling of CX43. Only spatial heterogeneity increased slightly with age, and this increase was better explained by biological age than by chronological age. Importantly, we found that CX43 features varied considerably among individuals in our population with no relevant relationship to age or fibrosis content, in contrast to animal species. We used our experimental results to feed computational models of human ventricular electrophysiology and to assess the effects of interindividual differences in specific features of CX43 and fibrosis on conduction velocity, action potential duration, and arrhythmogenicity. We found that larger amounts of fibrosis were associated with the highest arrhythmic risk, with this risk being increased when fibrosis deposition was combined with a reduction in CX43 amount and/or with an increase in CX43 spatial heterogeneity. These mechanisms underlying high arrhythmic risk in some individuals were not associated with age in our study population. In conclusion, our data rule out CX43 remodeling as an age-related arrhythmic substrate in the population beyond midlife, but highlight its potential as a proarrhythmic factor at the individual level, especially when combined with increased fibrosis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mathematical birth of early afterdepolarizations in a cardiomyocyte model

  • Barrio, R.
  • Jover-Galtier, J.A.
  • Martínez, M.A.
  • Pérez, L.
  • Serrano, S.
Early Afterdepolarizations (EADs) are abnormal behaviors that can lead to cardiac failure and even cardiac death. In this paper we investigate the occurrence and development of these phenomena in a reduced Luo–Rudy cardiac model. Through a comprehensive dynamical analysis, we map out the distinct patterns observed in the parametric plane, differentiating between normal beats without EADs and pathological beats with EADs. By examining the bifurcation structure of the model, we elucidate the dynamical elements associated with these patterns and their transitions. Using a fast–slow analysis, we explore the emergence and evolution of EADs in the model. Notably, our approach combines the two commonly used fast–slow approaches (1-slow–2-fast and 2-slow–1-fast), and we show how both approaches together provide a more complete understanding of this phenomenon.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG ventricular repolarization dynamics during exercise: Temporal profile, relation to heart rate variability and effects of age and physical health

  • Hernández-Vicente, Adrián
  • Hernando, David
  • Vicente-Rodríguez, Germán
  • Bailón, Raquel
  • Garatachea, Nuria
  • Pueyo, Esther
Periodic repolarization dynamics (PRD) is a novel electrocardiographic marker of cardiac repolarization instability with powerful risk stratification capacity for total mortality and sudden cardiac death. Here, we use a time-frequency analysis approach to continuously quantify PRD at rest and during exercise, assess its dependence on heart rate variability (HRV) and characterize the effects of age (young adults/middle-aged adults/older adults), body mass index (non-overweight/overweight) and cardiorespiratory fitness level (fit/unfit). Sixty-six male volunteers performed an exercise test. RR and dT variabilities (RRV, dTV), as well as the fraction of dT variability unrelated to RR variability, were computed based on time-frequency representations. The instantaneous LF power of dT (PdTV), representing the same concept as PRD, and of its RRV-unrelated component (PdTVuRRV) were quantified. dT angle was found to mostly oscillate in the LF band. Overall, 50-70% of PdTV was linearly unrelated to RRV. The onset of exercise caused a sudden increase in PdTV and PdTVuRRV, which returned to pre-exercise levels during recovery. Clustering analysis identified a group of overweight and unfit individuals with significantly higher PdTV and PdTVuRRV values at rest than the rest of the population. Our findings shed new light on the temporal profile of PRD during exercise, its relationship to HRV and the differences in PRD between subjects according to phenotypic characteristics. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Changes in T-peak-to-T-end Morphology Measured by Time-Warping Are Associated with Ischemia-Induced Ventricular Fibrillation in a Porcine Model

  • Gómez Fonseca, Neurys
  • Ramírez, Julia
  • Martin-Yebra, Alba
  • M. Demidova, Marina
  • Platonov, Pyotr
  • Martínez, Juan Pablo
  • Laguna, Pablo
In this work, we use a time-warping-based morphology variation index, dw , computed between the peak and the end of the T-wave, and assess its association with the occurrence of ventricular fibrillation (VF) episodes in ischemic conditions. ECG recordings from 26 pigs under- going a 40-minute coronary occlusion were analyzed. The dw series was obtained by quantifying the morphological differences between the final part of the T wave at different stages of the occlusion and a reference T wave in the control recording. During control recordings, dw remained stationary with a median value along each recording of 1.76 ms, IQR of 1.80, while during artery occlusion followed a well-marked gradual increasing trend as ischemia progressed, with median of 15.47 ms, IQR of 18.53. At the 20-to-25 min period from occlusion onset (and during 5 min prior to VF episode) d w averages in the VF group was significantly higher than in the non-VF group with median values of 40.0 (and 34.4) vs 7.8 (and 7.7) ms, with p-values of 0.002 (and 0.001), respectively. In conclusion, dynamic increases of the dw index during ischaemia progression in pigs are associated with VF occurrence.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The frequency of atrial fibrillatory waves is modulated by the spatiotemporal pattern of acetylcholine release: a 3D computational study

  • Celotto, Chiara
  • Sánchez, Carlos
  • Abdollahpur, Mostafa
  • Sandberg, Frida
  • Rodriguez Matas, Jose F.
  • Laguna, Pablo
  • Pueyo, Esther
In atrial fibrillation (AF), the ECG P-wave, which represents atrial depolarization, is replaced with chaotic and irregular fibrillation waves (f waves). The f-wave frequency, Ff, shows significant variations over time. Cardiorespiratory interactions regulated by the autonomic nervous system have been suggested to play a role in such variations. We conducted a simulation study to test whether the spatiotemporal release pattern of the parasympathetic neurotransmitter acetylcholine (ACh) modulates the frequency of atrial reentrant circuits. Understanding parasympathetic involvement in AF may guide more effective treatment approaches and could help to design autonomic markers alternative to heart rate variability (HRV), which is not available in AF patients. 2D tissue and 3D whole-atria models of human atrial electrophysiology in persistent AF were built. Different ACh release percentages (8% and 30%) and spatial ACh release patterns, including spatially random release and release from ganglionated plexi (GPs) and associated nerves, were considered. The temporal pattern of ACh release, ACh(t), was simulated following a sinusoidal waveform of frequency 0.125 Hz to represent the respiratory frequency. Different mean concentrations (ACh̄) and peak-to-peak ranges of ACh (ΔACh) were tested. We found that temporal variations in Ff, Ff(t), followed the simulated temporal ACh(t) pattern in all cases. The temporal mean of Ff(t), F̄f, depended on the fibrillatory pattern (number and location of rotors), the percentage of ACh release nodes and ACh̄. The magnitude of Ff(t) modulation, ΔFf, depended on the percentage of ACh release nodes and ΔACh. The spatial pattern of ACh release did not have an impact on F̄f and only a mild impact on ΔFf. The f-wave frequency, being indicative of vagal activity, has the potential to drive autonomic-based therapeutic actions and could replace HRV markers not quantifiable from AF patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Experimentally-guided in silico design of engineered heart tissues to improve cardiac electrical function after myocardial infarction

  • Rosales, Ricardo M.
  • Mountris, Konstantinos A.
  • Oliván-Viguera, Aida
  • Pérez-Zabalza, María
  • Cedillo-Servin, Gerardo
  • Iglesias-García, Olalla
  • Hrynevich, Andrei
  • Castilho, Miguel
  • Malda, Jos
  • Prósper, Felipe
  • Doblaré, Manuel
  • Mazo, Manuel M.
  • Pueyo, Esther
Engineered heart tissues (EHTs) built from human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) showed promising results for cardiac function restoration following myocardial infarction. Nevertheless, human iPSC-CMs have longer action potential and lower cell-to-cell coupling than adult-like CMs. These immature electrophysiological properties favor arrhythmias due to the generation of electrophysiological gradients when hiPSC-CMs are injected in the cardiac tissue. Culturing hiPSC-CMs on three-dimensional (3D) scaffolds can promote their maturation and influence their alignment. However, it is still uncertain how on-scaffold culturing influences the overall electrophysiology of the in vitro and implanted EHTs, as it requires expensive and time consuming experimentation. Here, we computationally investigated the impact of the scaffold design on the EHT electrical depolarization and repolarization before and after engraftment on infarcted tissue. We first acquired and processed electrical recordings from in vitro EHTs, which we used to calibrate the modeling and simulation of in silico EHTs to replicate experimental outcomes. Next, we built in silico EHT models for a range of scaffold pore sizes, shapes (square, rectangular, auxetic, hexagonal) and thicknesses. In this setup, we found that scaffolds made of small (0.2 mm2), elongated (30° half-angle) hexagons led to faster EHT activation and better mimicked the cardiac anisotropy. The scaffold thickness had a marginal role on the not engrafted EHT electrophysiology. Moreover, EHT engraftment on infarcted tissue showed that the EHT conductivity should be at least 5% of that in healthy tissue for bidirectional EHT-myocardium electrical propagation. For conductivities above such threshold, the scaffold made of small elongated hexagons led to the lowest activation time (AT) in the coupled EHT-myocardium. If the EHT conductivity was further increased and the hiPSC-CMs were uniformly oriented parallel to the epicardial cells, the total AT and the repolarization time gradient decreased substantially, thus minimizing the likelihood for arrhythmias after EHT transplantation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Analysis of age-related changes in the left ventricular myocardium with multiphoton microscopy

  • Bueno, Juan M.
  • Martínez-Ojeda, Rosa M.
  • Pérez-Zabalza, María
  • García-Mendívil, Laura
  • Asensio, M. Carmen
  • Ordovás, Laura
  • Pueyo, Esther
Aging induces cardiac remodeling, resulting in an increase in the risk of suffering heart diseases, including heart failure. Collagen deposition increases with age and, together with sarcomeric changes in cardiomyocytes, may lead to ventricular stiffness. Multiphoton (MP) microscopy is a useful technique to visualize and detect variations in cardiac structures in a label free fashion. Here, we propose a method based on MP imaging (both two-photon excitation fluorescence (TPEF) and second harmonic generation (SHG) modalities) to explore and objectively quantify age-related structural differences in various components of cardiac tissues. Results in transmural porcine left ventricle (LV) sections reveal significant differences when comparing samples from young and old animals. Collagen and myosin SHG signals in old specimens are respectively 3.8x and >6-fold larger than in young ones. Differences in TPEF signals from cardiomyocyte were ∼3x. Moreover, the increased amount of collagen in old specimens results in a more organized pattern when compared to young LV tissues. Since changes in collagen and myosin are associated with cardiac dysfunction, the technique used herein might be a useful tool to accurately predict and measure changes associated with age-related myocardium fibrosis, tissue remodeling and sarcomeric alterations, with potential implications in preventing heart disease.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Coupling of neurons favors the bursting behavior and the predominance of the tripod gait

  • Serrano, S.
  • Barrio, R.
  • Lozano, Á.
  • Mayora-Cebollero, A.
  • Vigara, R.
In nature, it has been observed that the dominant locomotor pattern of hexapod insects is often the tripod gait. Our analysis of a Central Pattern Generator (CPG) of the insect movement gives reasons for this dominance: the mathematical CPG model presents the tripod pattern with bursting dynamics in a parametric region where an isolated neuron has a simpler behavior. That is, we show how the coupling of small networks of neurons makes the system to continue having bursting dynamics even when an isolated neuron would be spiking. Moreover, in parametric regions where a neuron shows chaotic dynamics, the CPG exhibits a chaotic synchronization phenomenon: the chaotic tripod gait. In other words, coupling loves bursting… and tripod gait. The hyperchaotic phenomenon is also present and we locate regions where up to four Lyapunov exponents are positive.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Differences in ventricular wall composition may explain inter-patient variability in the ECG response to variations in serum potassium and calcium

  • Bukhari, Hassaan A.
  • Sánchez, Carlos
  • Laguna, Pablo
  • Potse, Mark
  • Pueyo, Esther
Objective: Chronic kidney disease patients have a decreased ability to maintain normal electrolyte concentrations in their blood, which increases the risk for ventricular arrhythmias and sudden cardiac death. Non-invasive monitoring of serum potassium and calcium concentration, [K + ] and [Ca 2+ ], can help to prevent arrhythmias in these patients. Electrocardiogram (ECG) markers that significantly correlate with [K + ] and [Ca 2+ ] have been proposed, but these relations are highly variable between patients. We hypothesized that inter-individual differences in cell type distribution across the ventricular wall can help to explain this variability.Methods: A population of human heart-torso models were built with different proportions of endocardial, midmyocardial and epicardial cells. Propagation of ventricular electrical activity was described by a reaction-diffusion model, with modified Ten Tusscher-Panfilov dynamics. [K + ] and [Ca 2+ ] were varied individually and in combination. Twelve-lead ECGs were simulated and the width, amplitude and morphological variability of T waves and QRS complexes were quantified.Results: Both simulations and patients data showed that most of the analyzed T wave and QRS complex markers correlated strongly with [K + ] (absolute median Pearson correlation coefficients, r, ranging from 0.68 to 0.98) and [Ca 2+ ] (ranging from 0.70 to 0.98). The same sign and similar magnitude of median r was observed in the simulations and the patients. Different cell type distributions in the ventricular wall led to variability in ECG markers that was accentuated at high [K + ] and low [Ca 2+ ], in agreement with the larger variability between patients measured at the onset of HD. The simulated ECG variability explained part of the measured inter-patient variability.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mathematical Model of CAR T-Cell Therapy for a B-Cell Lymphoma Lymph Node

  • Sabir, Soukaina
  • León-Triana, Odelaisy
  • Serrano, Sergio
  • Barrio, Roberto
  • Pérez-García, Victor M.
CAR T-cell therapies have demonstrated significant success in treating B-cell leukemia in children and young adults. However, their effectiveness in treating B-cell lymphomas has been limited in comparison to leukemia. In this paper we present a mathematical model that elucidates the dynamics of diffuse large B-cell lymphoma and CAR T-cells in a lymph node. The mathematical model aids in understanding the complex interplay between the cell populations involved and proposes ways to identify potential underlying dynamical causes of treatment failure. We also study the phenomenon of immunosuppression induced by tumor cells and theoretically demonstrate its impact on cell dynamics. Through the examination of various response scenarios, we underscore the significance of product characteristics in treatment outcomes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Human in silico modeling guided by transcriptomics predicts drug-induced proarrhythmicity as a function of age

  • Garrido-Huéscar, Elisa
  • Rosales, Ricardo Maximiliano
  • Pérez Zabalza, María
  • Laguna, Pablo
  • Ordovás, Laura
  • Pueyo, Esther
Background and Objective Unexpected cardiotoxicity is a major cause of drug failure during development and can also contribute to market withdrawal. Traditional preclinical models and clinical trials do not fully capture age-related cardiac functional decline, which is associated with increased arrhythmic risk. We aimed to develop human-based in silico electrophysiology models incorporating age-related remodeling to improve the assessment of age-dependent drug-induced cardiotoxicity during drug development. Methods Biological and chronological transcriptomic age-related human ventricular ionic remodeling was integrated into the O’Hara-Virag-Varro-Rudy model of ventricular electrophysiology at both cellular and tissue levels. Cardiac biological age was represented using two independent gene expression-based indices: SenesAge, based on one senescent gene, and AppAge, based on nearly 2,000 age-related genes. A panel of 12 reference drugs was used to evaluate age-related drug-induced cardiotoxicity. Results In silico aging based on SenesAge and AppAge reproduced age-related electrophysiological phenotypes at the cellular, tissue, and ECG levels more closely than chronological age-based remodeling. Biological age-related remodeling also increased the susceptibility to arrhythmogenic events following drug exposure by more than fivefold with respect to the adult population across the majority of tested conditions, although the effects varied according to the drug and its concentration. Conclusions This study provides a novel perspective for incorporating biological age-related remodeling into an established human-based in silico framework for preclinical cardiotoxicity evaluation at the population level. Our findings support biological age-based modeling as a complement to chronological age-based approaches for improving age-specific drug-induced cardiac risk assessment.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Weighted time warping improves T-wave morphology markers clinical significance

  • Palmieri, Flavio
  • Gomis Román, Pedro
  • Ferreira, Dina
  • Pueyo, Esther
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Ramírez, Julia
Background: T-wave (TW) morphology indices based on time-warping (dw) have shown significant cardiovascular risk stratification value. However, errors in the location of TW boundaries may impact their prognostic power. Our aim was to test the hypothesis that a weighted time-warping function (WF) would reduce the sensitivity of dw to these errors and improve their clinical significance. Methods: The WFs were proportional to (i) the reference TW (T), and (ii) the absolute value of its derivative (D). The index dw was recalculated using these WFs, and its performance was compared to the unweighted control case (C) in four different scenarios: 1) robustness against simulated TW boundaries location errors; 2) ability to retain physiological information in an electrophysiological cardiac model; 3) ability to monitor blood potassium concentration changes ([K+]) in 29 hemodialysis (HD) patients; 4) and the sudden cardiac death (SCD) risk stratification value of the TW morphology restitution (TMR) index, derived from dw, in 651 chronic heart failure (CHF) patients. Results and Discussion: The WFs led to a reduced sensitivity (R) of dw to TW boundary location errors as compared to C (median R=0.19 and 0.22 and 0.35 for T, D and C, respectively). They also preserved the physiological relationship between dw and repolarization dispersion changes at ventricular level. No improvements in [K+] tracking were observed for the HD patients (Pearsons median correlation [r] between [K+] and dw was 0.86r0.90 for T, D and C). In CHF patients, the SCD risk stratification value of TMR was improved by applying T (hazard ratio, HAR, of 2.80), followed by D (HAR=2.32) and C (HAR=2.23). Conclusions and Significance: The proposed WFs, with T showing the best performance, increased the robustness of time-warping based markers against TW location errors preserving their physiological information content and boosting their SCD risk stratification value. Results from this work support the use of T when deriving dw for future clinical applications., This work was funded by Products&TechnologyS.L. (Castellbisbal,Barcelona,Spain),and by AGAUR,Generalitat de Catalunya (Spain) grant DI001-2018 and CIBER-BBN ref:“DEKOALE”.The work was also supported by project PID2019-104881RB-I00, and PID2019-105674 RB-I00 funded bySpanish Ministry of Science and Innovation (MICINN) and FEDER, by Gobierno de Aragón (Reference Group Biomedical Signal Interpretation and Computational Simulation (BSICoS)) T39-20 Rand projects LMP94-21,LMP14121cofunded by FEDER 2014-2020 “Building Europe from Aragón”, J.R. acknowledge the “María Zambrano” fellowship support from the European Union-Next Generation EU and the support from the Marie Sklodowska-Curie grant No786833. The computation was performed at the High Performance computing platform of the NANBIOSISICTS., Peer Reviewed, Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Meshless electrophysiological modeling of cardiac resynchronization therapy: benchmark analysis with finite-element methods in experimental data

  • Albors Lucas, Carlos
  • Lluch Álvarez, Èric
  • Gomez, Juan Francisco
  • Cedilnik, Nicolas
  • Mountris, Konstantinos A.
  • Mansi, Tommaso
  • Khamzin, Svyatoslav
  • Dokuchaev, Arsenii
  • Solovyova, Olga
  • Pueyo, Esther
  • Sermesant, Maxime
  • Sebastian, Rafael
  • Morales, Hernán G.
  • Camara, Oscar
Computational models of cardiac electrophysiology are promising tools for reducing the rates of non-response patients suitable for cardiac resynchronization therapy (CRT) by optimizing electrode placement. The majority of computational models in the literature are mesh-based, primarily using the finite element method (FEM). The generation of patient-specific cardiac meshes has traditionally been a tedious task requiring manual intervention and hindering the modeling of a large number of cases. Meshless models can be a valid alternative due to their mesh quality independence. The organization of challenges such as the CRT-EPiggy19, providing unique experimental data as open access, enables benchmarking analysis of different cardiac computational modeling solutions with quantitative metrics. We present a benchmark analysis of a meshless-based method with finite-element methods for the prediction of cardiac electrical patterns in CRT, based on a subset of the CRT-EPiggy19 dataset. A data assimilation strategy was designed to personalize the most relevant parameters of the electrophysiological simulations and identify the optimal CRT lead configuration. The simulation results obtained with the meshless model were equivalent to FEM, with the most relevant aspect for accurate CRT predictions being the parameter personalization strategy (e.g., regional conduction velocity distribution, including the Purkinje system and CRT lead distribution)., This work was supported in part by the Spanish Ministry of Science and Innovation (TIN2011-28067, REDINSCOR RD06/003/008, PID2019-105674RB-I00), the Spanish Industrial and Technological Development Center (cvREMOD-CEN-20091044), the Spanish Ministry of Economy and Competitiveness under the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502), the Government of Aragón (Spain) (LMP94_21), the Directorate General of Science Policy of the Generalitat Valenciana (Spain) (PROMETEU 2016/088), the Seventh Framework Programme (FP7/2007-2013) for research, technological and demonstration under grant agreement VP2HF (no. 611823), by the RSF grant no. 19-14-00134, and by European Regional Development Fund (ERDF) DPI2016-75799-R (AEI/ERDF, EU).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

QRS-T angles as markers for heart sphericity in subjects with intrauterine growth restriction: a simulation study

  • Bueno-Palomeque, Freddy L.
  • Mountris, Konstantinos A.
  • Ortigosa, Núria
  • Bailón, Raquel
  • Bijnens, Bart
  • Crispi Brillas, Fàtima
  • Pueyo, Esther
  • Mincholé, Ana
  • Laguna, Pablo
This work was supported in part by Fundación Carolina and Universidad Politénica Salesiana, in part by the Spanish Ministry of Science and Innovation (MICINN) and FEDER Una manera de hacer Europa under Grants PID2019-105674RB-I00, PID2021-128972OA-I00, TED2021-130459B-I00, and PID2020-119457GB-100, through Ramon y Cajal Program under Grant RYC2019-027420-I, in part by the Gobierno de Aragon, Reference Group BSICoS T39-20R, and in part by Project LMP94_21.