Pasar al contenido principal

CLINICALLY-GUIDED DATA PROCESSING METHODS AND IN SILICO MODELS TO IMPROVE PATIENT STRATIFICATION AND THERAPY RESPONSE IN CARDIAC AND NEUROLOGICAL DISORDERS

PID2022-140556OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 43
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Fiber-Optic-Based System for High-Resolution Monitoring of Stretch in Excised Tissues

  • Velarte, Antonio
  • Otin, Aranzazu
  • Giménez-Gómez, Pablo
  • Muñoz-Berbel, Xavier
  • Pueyo, Esther
Cardiovascular diseases cause a high number of deaths nowadays. To improve these statistics, new strategies to better understand the electrical and mechanical abnormalities underlying them are urgently required. This study focuses on the development of a sensor to measure tissue stretch in excised tissues, enabling improved knowledge of biomechanical properties and allowing greater control in real time. A system made of biocompatible materials is described, which is based on two cantilevered platforms that integrate an optical fiber inside them to quantify the amount of stretch the tissues are exposed to with a precision of μ m. The operating principle of the sensor is based on the variation of the optical path with the movement of the platforms onto which the samples are fixed. The conducted tests highlight that this system, based on a simple topology and technology, is capable of achieving the desired purpose (a resolution of ∼1 μ m), enabling the tissue to be bathed in any medium within the system., This work was funded by projects PID2019-105674RB-I00, RTI2018-100773-B-C31, PID2021-127653NB-C21, PID2022-140556OB-I00 and TED2021-130459B-I00 by Ministerio de Ciencia e Innovación, ERC grant 638284 by European Research Council and projects LMP94_21 and BSICoS T39_23R by European Social Fund (EU) and Aragón Government., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Temporal variability of ventricular activation in brugada syndrome patients

  • Romagnoli, Sofía
  • Isabel Roquero, Alba
  • Martín-Yebra, Alba
  • Palmieri, Flavio|||0000-0002-1455-4923
  • Pueyo Paules, Esther
  • Gomis Román, Pedro|||0000-0002-2058-7115
  • Laguna Lasaosa, Pablo
  • Arbelo Lainez, Elena
  • Mincholé, Ana
In Brugada Syndrome (BrS), ventricular fibrillation events peak during night. This temporal pattern suggests that circadianity may modulate arrhythmogenesis. The present work evaluates the circadianity of ventricular activation in BrS patients from 24-hour ECGs with the high-precordial leads. Lead-dependent propagation progression times, \(T_l^p(h)\), are computed every \(h\)-th half hour in each \(l\)-th lead as the time instant along the QRS complex when the QRS energy reaches a percentage, \(p\), of the total QRS energy. \(T_l^p(h)\) is characterized by median and standard deviation over 24 hours, as well as the MESOR and amplitude of the cosinor analysis. The median and MESOR of \(T_l^{70}(h)\) are longer by more than 10 ms in BrS patients than in controls. In particular, the median and standard deviation of \(T_l^p(h)\) at different energy percentages can distinguish between BrS vs controls (\(\mathrm{AUC} \geq 0.8\)), and BrS-I vs BrS-II (\(\mathrm{AUC} = 0.78\)). Cosinor analysis indicates that \(T_l^p(h)\) is less influenced by circadianity than heart rate. The Spearman correlation of \(T_l^p(h)\) with heart rate is lower than 0.5 in each lead for both BrS and controls. These findings suggest that intra-day variability in propagation progression times is not primarily driven by circadianity or heart rate. Furthermore, the temporal variability of \(T_l^p(h)\) is higher in symptomatic BrS patients supporting its potential role as risk stratification marker in BrS., Funding was provided ISCIII Spain (ref: PI24/00691); EU Reference Network ERN GUARD-Heart; MICIN through projects CNS2022-135899, TED2021-130459B- I00, PID2023-148975OB-I00 and PID2022-140556OBI00, through fellowship RYC2019-027420-I; Aragon Government group: BSICoS T39 23R; EU MSCA COFOUND postdoct project ARISTOS, GA:101081334., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

T-wave peak-to-end morphology restitution as biomarker in Brugada syndrome

  • Gómez, Neurys
  • Ramírez, Julia
  • Isabel Roquero, Alba
  • Palmieri, Flavio|||0000-0002-1455-4923
  • Arbelo Lainez, Elena
  • Mártinez, Juan Pablo
  • Laguna Lasaosa, Pablo
Brugada syndrome (BrS) is a genetic disorder that affects the ion channels of the cardiac myocites, resulting in a higher predisposition to malignant ventricular arrhythmias and sudden cardiac death (SCD). Risk stratification and management of BrS patients remains a major clinical challenge. In this work, we use a time-warping-based index of the T-wave peak-to-end morphological restitution (TPEMR) to quantify the restitution properties of the late phase of ventricular repolarization and evaluate its ability to distinguish between control and BrS patients and between symptomatic (BrS-S) and asymptomatic patients (BrS-A). 24-hour Holter ECG recordings from 89 BrS patients (29 asymptomatic, BrS-A, and 60 symptomatic, BrS-S) and 32 healthy control patients were analyzed. The original, unweighted \(\mathrm{TPEMR}_{O}\) as well as weighted versions with two different strategies \(\mathrm{TPEMR}_{W1}\) and \(\mathrm{TPEMR}_{W2}\) are computed. \(\mathrm{TPEMR}\) derives from a time-warping, \(d\mathrm{PCA}^{w,T_{pe}}\), index computed from T waves at two distant RR bins normalized by the RR range. All the three TPEMR indices were significantly higher for BrS group than for the control group. BrS-S group presented higher TPEMR indexes than BrS-A group for all indices, though significant differences were only shown in the weighted \(\mathrm{TPEMR}_{W2}\) index., Funding was provided by MICIN, Spain, projects: PID2022-140556OB-I00, CNS2023-143599 and TED2021-130459B-I00, and fellowship RYC2021-031413-I, and by Aragon Government group: BSICoS T39 23R., Peer Reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Fiber-Optic-Based System for High-Resolution Monitoring of Stretch in Excised Tissues

  • Velarte, Antonio
  • Otin, Aranzazu
  • Giménez-Gómez, Pablo
  • Muñoz-Berbel, Xavier
  • Pueyo, Esther
Cardiovascular diseases cause a high number of deaths nowadays. To improve these statistics, new strategies to better understand the electrical and mechanical abnormalities underlying them are urgently required. This study focuses on the development of a sensor to measure tissue stretch in excised tissues, enabling improved knowledge of biomechanical properties and allowing greater control in real time. A system made of biocompatible materials is described, which is based on two cantilevered platforms that integrate an optical fiber inside them to quantify the amount of stretch the tissues are exposed to with a precision of μm. The operating principle of the sensor is based on the variation of the optical path with the movement of the platforms onto which the samples are fixed. The conducted tests highlight that this system, based on a simple topology and technology, is capable of achieving the desired purpose (a resolution of ∼1 μm), enabling the tissue to be bathed in any medium within the system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A Flexible PDMS-Based Optical Biosensor for Stretch Monitoring in Cardiac Tissue Samples

  • Sannino, Andrea
  • Velarte, Antonio
  • Otín, Aránzazu
  • Artigas, José Ignacio
  • Oliván-Viguera, Aida
Cardiotoxicity, characterized by adverse impacts on normal heart function due to drug exposure, is a significant concern due to the potentially serious side effects associated with various pharmaceuticals. It is essential to detect the cardiotoxicity of a drug as early as possible in the testing phase of a medical composite. Therefore, there is a pressing need for more reliable in vitro models that accurately mimic the in vivo conditions of cardiac biopsies. In a functional beating heart, cardiac muscle cells are under the effect of static and cyclic stretches. It has been demonstrated that cultured cardiac biopsies can benefit from external mechanical loads that resemble the in vivo condition, increasing the probability of cardiotoxicity detection in the early testing stages. In this work, a biosensor is designed and fabricated to allow for stretch monitoring in biopsies and tissue cultures using an innovative sensing mechanism. The detection setup is based on a biocompatible, thin, flexible membrane—where the samples are attached—which is used as an optical waveguide to detect pressure-caused shape changes and stretches. Various prototypes have been fabricated with a cost-effective process, and different measurements have been carried out to experimentally validate the proposed measurement technique. From these evaluations, stretches of up to 1.5% have been measured, but the performed simulations point towards the possibility of expanding the considered technique up to 10–30% stretches.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Interindividual Age-Independent Differences in Human CX43 Impact Ventricular Arrhythmic Risk

  • García-Mendívil, Laura
  • Pérez-Zabalza, María
  • Oliver-Gelabert, Antoni
  • Vallejo-Gil, José María
  • Fañanás-Mastral, Javier
  • Vázquez-Sancho, Manuel
  • Bellido-Morales, Javier André
  • Vaca-Núñez, Alexánder Sebastián
  • Ballester-Cuenca, Carlos
  • Diez, Emiliano
  • Ordovás, Laura
  • Pueyo, Esther
Connexin 43 (CX43) is one of the major components of gap junctions, the structures responsible for the intercellular communication and transmission of the electrical impulse in the left ventricle. There is limited information on the histological changes of CX43 with age and their effect on electrophysiology, especially in humans. Here, we analyzed left ventricular biopsies from living donors starting at midlife to characterize age-related CX43 remodeling. We assessed its quantity, degree of lateralization, and spatial heterogeneity together with fibrotic deposition. We observed no significant age-related remodeling of CX43. Only spatial heterogeneity increased slightly with age, and this increase was better explained by biological age than by chronological age. Importantly, we found that CX43 features varied considerably among individuals in our population with no relevant relationship to age or fibrosis content, in contrast to animal species. We used our experimental results to feed computational models of human ventricular electrophysiology and to assess the effects of interindividual differences in specific features of CX43 and fibrosis on conduction velocity, action potential duration, and arrhythmogenicity. We found that larger amounts of fibrosis were associated with the highest arrhythmic risk, with this risk being increased when fibrosis deposition was combined with a reduction in CX43 amount and/or with an increase in CX43 spatial heterogeneity. These mechanisms underlying high arrhythmic risk in some individuals were not associated with age in our study population. In conclusion, our data rule out CX43 remodeling as an age-related arrhythmic substrate in the population beyond midlife, but highlight its potential as a proarrhythmic factor at the individual level, especially when combined with increased fibrosis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A Multi-layer CNN Using the ECG, Age and Sex Predicts Ventricular Arrhythmias in the General Population

  • Ramírez, Julia
  • Miguel, Antonio
  • van Duijvenboden, Stefan
  • Orini, Michele
  • Young, William J.
  • Tinker, Andrew
  • Lambiase, Pier D.
  • Munroe, Patricia B.
  • Martínez, Juan Pablo
Life-threatening ventricular arrhythmias (LTVA) prediction in individuals without cardiovascular disease remains a major challenge. We tested the performance of a multilayer convolutional neural network (CNN) using ECG signals, age and sex. We split 86,603 individuals from the UK Biobank study into a training (90%) and a test (10%) set. In the training set, we trained a multilayer CNN using 15-second ECGs at rest from lead I, age and sex as inputs. The output was the probability of LTVA within a 12-year follow-up. The CNN model consisted of a four-layer CNN (128, 128, 256 and 256 channels, kernel sizes of 3) and a single attention layer. Age and sex were included as external inputs to the final layer. In the test set (0.9% LTVA events), the CNN's prediction led to a median AUC of 0.601, and a specificity of 0.287 for a sensitivity of 0.750. We set a threshold at the CNN's prediction value maximising the sum of specificity and sensitivity in the training set. Survival analyses showed a hazard ratio (HR) of 1.396(P=0.021) for individuals with a CNN's prediction value > threshold, versus those with a CNN's prediction value < threshold. A multilayer CNN model using 10-second ECG data from lead I, together with information on age and sex, can stratify individuals at risk of LTVA. Our findings support the potential utility of wearables for accessible screening in the general population.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The frequency of atrial fibrillatory waves is modulated by the spatiotemporal pattern of acetylcholine release: a 3D computational study

  • Celotto, Chiara
  • Sánchez, Carlos
  • Abdollahpur, Mostafa
  • Sandberg, Frida
  • Rodriguez Matas, Jose F.
  • Laguna, Pablo
  • Pueyo, Esther
In atrial fibrillation (AF), the ECG P-wave, which represents atrial depolarization, is replaced with chaotic and irregular fibrillation waves (f waves). The f-wave frequency, Ff, shows significant variations over time. Cardiorespiratory interactions regulated by the autonomic nervous system have been suggested to play a role in such variations. We conducted a simulation study to test whether the spatiotemporal release pattern of the parasympathetic neurotransmitter acetylcholine (ACh) modulates the frequency of atrial reentrant circuits. Understanding parasympathetic involvement in AF may guide more effective treatment approaches and could help to design autonomic markers alternative to heart rate variability (HRV), which is not available in AF patients. 2D tissue and 3D whole-atria models of human atrial electrophysiology in persistent AF were built. Different ACh release percentages (8% and 30%) and spatial ACh release patterns, including spatially random release and release from ganglionated plexi (GPs) and associated nerves, were considered. The temporal pattern of ACh release, ACh(t), was simulated following a sinusoidal waveform of frequency 0.125 Hz to represent the respiratory frequency. Different mean concentrations (ACh̄) and peak-to-peak ranges of ACh (ΔACh) were tested. We found that temporal variations in Ff, Ff(t), followed the simulated temporal ACh(t) pattern in all cases. The temporal mean of Ff(t), F̄f, depended on the fibrillatory pattern (number and location of rotors), the percentage of ACh release nodes and ACh̄. The magnitude of Ff(t) modulation, ΔFf, depended on the percentage of ACh release nodes and ΔACh. The spatial pattern of ACh release did not have an impact on F̄f and only a mild impact on ΔFf. The f-wave frequency, being indicative of vagal activity, has the potential to drive autonomic-based therapeutic actions and could replace HRV markers not quantifiable from AF patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Experimentally-guided in silico design of engineered heart tissues to improve cardiac electrical function after myocardial infarction

  • Rosales, Ricardo M.
  • Mountris, Konstantinos A.
  • Oliván-Viguera, Aida
  • Pérez-Zabalza, María
  • Cedillo-Servin, Gerardo
  • Iglesias-García, Olalla
  • Hrynevich, Andrei
  • Castilho, Miguel
  • Malda, Jos
  • Prósper, Felipe
  • Doblaré, Manuel
  • Mazo, Manuel M.
  • Pueyo, Esther
Engineered heart tissues (EHTs) built from human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) showed promising results for cardiac function restoration following myocardial infarction. Nevertheless, human iPSC-CMs have longer action potential and lower cell-to-cell coupling than adult-like CMs. These immature electrophysiological properties favor arrhythmias due to the generation of electrophysiological gradients when hiPSC-CMs are injected in the cardiac tissue. Culturing hiPSC-CMs on three-dimensional (3D) scaffolds can promote their maturation and influence their alignment. However, it is still uncertain how on-scaffold culturing influences the overall electrophysiology of the in vitro and implanted EHTs, as it requires expensive and time consuming experimentation. Here, we computationally investigated the impact of the scaffold design on the EHT electrical depolarization and repolarization before and after engraftment on infarcted tissue. We first acquired and processed electrical recordings from in vitro EHTs, which we used to calibrate the modeling and simulation of in silico EHTs to replicate experimental outcomes. Next, we built in silico EHT models for a range of scaffold pore sizes, shapes (square, rectangular, auxetic, hexagonal) and thicknesses. In this setup, we found that scaffolds made of small (0.2 mm2), elongated (30° half-angle) hexagons led to faster EHT activation and better mimicked the cardiac anisotropy. The scaffold thickness had a marginal role on the not engrafted EHT electrophysiology. Moreover, EHT engraftment on infarcted tissue showed that the EHT conductivity should be at least 5% of that in healthy tissue for bidirectional EHT-myocardium electrical propagation. For conductivities above such threshold, the scaffold made of small elongated hexagons led to the lowest activation time (AT) in the coupled EHT-myocardium. If the EHT conductivity was further increased and the hiPSC-CMs were uniformly oriented parallel to the epicardial cells, the total AT and the repolarization time gradient decreased substantially, thus minimizing the likelihood for arrhythmias after EHT transplantation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Coupling of neurons favors the bursting behavior and the predominance of the tripod gait

  • Serrano, S.
  • Barrio, R.
  • Lozano, Á.
  • Mayora-Cebollero, A.
  • Vigara, R.
In nature, it has been observed that the dominant locomotor pattern of hexapod insects is often the tripod gait. Our analysis of a Central Pattern Generator (CPG) of the insect movement gives reasons for this dominance: the mathematical CPG model presents the tripod pattern with bursting dynamics in a parametric region where an isolated neuron has a simpler behavior. That is, we show how the coupling of small networks of neurons makes the system to continue having bursting dynamics even when an isolated neuron would be spiking. Moreover, in parametric regions where a neuron shows chaotic dynamics, the CPG exhibits a chaotic synchronization phenomenon: the chaotic tripod gait. In other words, coupling loves bursting… and tripod gait. The hyperchaotic phenomenon is also present and we locate regions where up to four Lyapunov exponents are positive.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Performance evaluation of QT-RR adaptation time lag estimation in exercise stress testing

  • Pérez, C.
  • Pueyo, E.
  • Martínez, J. P.
  • Viik, J.
  • Sornmo, L.
  • Laguna, P.
Background: Slower adaptation of the QT interval to sudden changes in heart rate has been identified as a risk marker of ventricular arrhythmia. The gradual changes observed in exercise stress testing facilitates the estimation of the QT-RR adaptation time lag. Methods: The time lag estimation is based on the delay between the observed QT intervals and the QT intervals derived from the observed RR intervals using a memoryless transformation. Assuming that the two types of QT interval are corrupted with either Gaussian or Laplacian noise, the respective maximum likelihood time lag estimators are derived. Estimation performance is evaluated using an ECG simulator which models change in RR and QT intervals with a known time lag, muscle noise level, respiratory rate, and more. The accuracy of T-wave end delineation and the influence of the learning window positioning for model parameter estimation are also investigated. Results: Using simulated datasets, the results show that the proposed approach to estimation can be applied to any changes in heart rate trend as long as the frequency content of the trend is below a certain frequency. Moreover, using a proper position of the learning window for exercise so that data compensation reduces the effect of nonstationarity, a lower mean estimation error results for a wide range of time lags. Using a clinical dataset, the Laplacian-based estimator shows a better discrimination between patients grouped according to the risk of suffering from coronary artery disease. Conclusions : Using simulated ECGs, the performance evaluation of the proposed method shows that the estimated time lag agrees well with the true time lag.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Differences in ventricular wall composition may explain inter-patient variability in the ECG response to variations in serum potassium and calcium

  • Bukhari, Hassaan A.
  • Sánchez, Carlos
  • Laguna, Pablo
  • Potse, Mark
  • Pueyo, Esther
Objective: Chronic kidney disease patients have a decreased ability to maintain normal electrolyte concentrations in their blood, which increases the risk for ventricular arrhythmias and sudden cardiac death. Non-invasive monitoring of serum potassium and calcium concentration, [K + ] and [Ca 2+ ], can help to prevent arrhythmias in these patients. Electrocardiogram (ECG) markers that significantly correlate with [K + ] and [Ca 2+ ] have been proposed, but these relations are highly variable between patients. We hypothesized that inter-individual differences in cell type distribution across the ventricular wall can help to explain this variability.Methods: A population of human heart-torso models were built with different proportions of endocardial, midmyocardial and epicardial cells. Propagation of ventricular electrical activity was described by a reaction-diffusion model, with modified Ten Tusscher-Panfilov dynamics. [K + ] and [Ca 2+ ] were varied individually and in combination. Twelve-lead ECGs were simulated and the width, amplitude and morphological variability of T waves and QRS complexes were quantified.Results: Both simulations and patients data showed that most of the analyzed T wave and QRS complex markers correlated strongly with [K + ] (absolute median Pearson correlation coefficients, r, ranging from 0.68 to 0.98) and [Ca 2+ ] (ranging from 0.70 to 0.98). The same sign and similar magnitude of median r was observed in the simulations and the patients. Different cell type distributions in the ventricular wall led to variability in ECG markers that was accentuated at high [K + ] and low [Ca 2+ ], in agreement with the larger variability between patients measured at the onset of HD. The simulated ECG variability explained part of the measured inter-patient variability.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of QT-interval adaptation time lag in response to sport-induced heart rate changes measured from wearable ECG recordings

  • Romagnoli, Sofia
  • Sbrollini, Agnese
  • Burattini, Laura
  • Martinez, Juan Pablo
  • Laguna, Pablo
Objectives: Elevated heterogeneity in ventricular repolarization can promote malignant ventricular arrhythmias. During exercise, distinct ventricular cells may present different repolarization adaptation to heart-rate (HR) changes potentially increasing ventricular repolarization dispersion. An electrocar-diographic descriptor of the temporal adaptation of action potential duration to HR changes is the time delay the QT interval takes in accommodating to abrupt acceleration and deceleration in HR. Previous investigations have been performed on standard electrocardiograms acquired during stress tests. The present work aims to characterize the time delay of QT-interval accommodation to HR changes for a healthy trained population during real training. Methods: The time delay was estimated through an optimally derived, model-based time-delay estimator as the lag between the actual QT series and an HR-derived expected memoryless QT series. The last one was obtained by fitting a logarithmic regression model to the instantaneous QT and HR measurements in assumed stationary time windows. The QT lag was estimated separately in HR acceleration, and HR deceleration, of single-lead ECG acquired through a chest strap while practicing sport. Results: The QT-adaptation time lag estimated during HR deceleration is longer than during HR acceleration, especially after intense physical exertion of athletes when they have overcome their theoretical maximal HR 14.5[2.4;28.0] s or they have been involved in dynamic sports 9.9[5.8;24.9] s. Conclusion: Higher repolarization dispersion can be captured by the proposed time delay biomarker in a distinctive way to the HR acceleration. Significance: Eventually the time lag is a biomarker for exacerbated increase of ventricular repolarization dispersion while exercising.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Biologically-Inspired Melt Electrowriting for the Generationof Highly Biomimetic Functional Myocardium

  • Iglesias-García, Olalla
  • Flandes-Iparraguirre, María
  • Montero-Calle, Pilar
  • Rosales, Ricardo M.
  • Ullate-Agote, Asier
  • Sánchez-Bueno, Andrea
  • Larequi, Eduardo
  • Anaut-Lusar, Ilazki
  • Laita, Nicolás
  • Oliván-Viguera, Aida
  • Iglesias, Elena
  • Abizanda, Gloria
  • San Martín-Úriz, Patxi
  • Aguirre-Ruiz, Paula
  • Aranguren, Xabier L.
  • García de Yébenes, Manuel
  • Gavira, Juan José
  • Martínez, Miguel Ángel
  • Peña, Estefanía
  • Doblaré, Manuel
  • de-Juan-Pardo, Elena M.
  • Pueyo, Esther
  • Prosper, Felipe
  • Mazo Vega, Manuel M.
In the heart, the specific 3D structure of myocardial layers produces an efficient ejection of blood. When myocardial infarction strikes, this architecture is disrupted, adding a disarranged contraction to the decreased availability of pumping units (cardiomyocytes, CMs). In this work, the alignment of cardiac fibers in a large animal model (pig) is characterized and employ melt electrowriting (MEW) to fabricate a bio-inspired scaffold with diamond-shaped pores. Using human-induced pluripotent stem cell-derived CMs and cardiac fibroblasts, human cardiac tissues with a biomimetic in-plane contraction are generated. MEW-diamond tissues beat macroscopically for over 1 month, with significantly faster kinetics, increased force, and higher conduction velocity than those based on square or rectangular pores. The diamond design induces a specific hiPSC-CM alignment resulting in the observed in-plane contraction. Transcriptomic analysis using bulk RNA-seq reveals diamond-MEW tissues present features of maturation as compared to traditional 2D cultures. Finally, the bio-inspired cardiac tissues are employed to treat an infarction model in athymic rats, showing a significant benefit on systolic function and remodeling, tied to the presence of large grafts of human cells remuscularizing the ventricular wall. All in all, it is demonstrated that the new design generates superior human cardiac tissues with therapeutic capacity.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG-based evaluation of ventricular synchrony in left bundle branch area pacing through characterization of the activation sequence

  • Sales-Belles, Clara
  • Mincholé, Ana
  • Melero-Polo, Jorge
  • Cabrera-Ramos, Mercedes
  • Vadillo-Martín, Pablo
  • Montilla-Padilla, Isabel
  • Sorinas-Villanueva, Laura
  • Julián-García, Inés
  • Mayo-Carlos, Gualber Vitto
  • Ruiz-Arroyo, José Ramón
  • Pueyo, Esther
  • Ramos-Maqueda, Javier
Left bundle branch area pacing (LBBAP) overcomes ventricular dyssynchrony induced by conventional right ventricular pacing (RVP). Despite QRS duration (QRSd) being the standard ECG marker for biventricular synchrony, it lacks insights into the ventricular activation sequence. Our aim is to assess biventricular synchrony by characterizing the ventricular activation sequence and introducing robust markers using the 12-lead ECG. A prospective single-center study was conducted, involving patients with pacemaker indication due to bradycardia. Patients were divided into LBBAP and RVP, and classified by baseline-QRS morphology. To assess biventricular synchrony, low frequency-based QRS analysis was performed to compute the ventricular activation sequence and precordial activation delay (pAD). Additional QRS markers including QRSd, QRS60, and QRS area (QRSa) were calculated. A total of 176 patients (107 LBBAP, 69 RVP) were included. The paced ventricular activation sequence indicated a more physiological pattern after LBBAP than RVP, with lower pAD values in narrow QRS, RBBB, and LBBB subgroups [ − 10( − 20,14) vs. 26(5, 39) ms;  − 18( − 30,  − 8) vs. 34(26, 55) ms; 10( − 14, 25) vs. 32(12, 48) ms] (p < 0.01). In all subgroups, QRS60 showed lower values after LBBAP than RVP [52(41, 62) vs.73(65, 80) ms; 60(55, 66) vs. 77(67, 83) ms; 59(53, 64) vs. 77(74, 82) ms] (p < 0.01) and QRSa were also lower [53(38, 66) vs. 121(92, 143) μVs; 60(50, 89) vs. 124(97, 159) μVs; 62(52, 80) vs. 133(99, 148) μVs] (p < 0.01). pAD provides valuable insights into ventricular activation beyond paced-QRSd. Together with QRS60 and QRSa, pAD could be a promising tool to assess biventricular synchrony.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Variability and reliability of the Axivity AX6 accelerometer in technical and human motion conditions

  • Echevarría-Polo, Marcos
  • Marín, Pedro J.
  • Pueyo, Esther
  • Ramos Maqueda, Javier
  • Garatachea, Nuria
This study aimed to evaluate the intra- and inter-instrument variability and reliability of the Axivity AX6 accelerometer under controlled technical conditions and human motion scenarios. In the first experiment, 12 accelerometers were affixed to a vibration platform and tested at four frequencies (2.2, 3.2, 6.5, and 9.4 Hz) along three axes to assess frequency- and axis-dependent variability. In the second experiment, four AX6 accelerometers were simultaneously placed on a subject’s wrist and tested under four human motion conditions (walking at 4 km·h−1 and 6 km·h−1 and running at 8 km·h−1 and 10 km·h−1). Results demonstrated low intra- and inter-instrument variability (CVintra: 3.3–4.5%; CVinter: 6.3–7.7%) with high reliability (ICC = 0.98). Similar results were observed in human motion conditions (CVintra: 5.3–8.8%; CVinter: 7.1–10.4%), with ICC values of 0.98 for combined devices, and 0.99 for each device individually. Despite statistically significant differences (p < 0.05) between devices in human motion all conditions, the variations remained below the minimal clinically significant difference threshold. These findings indicate that under technical conditions on a vibrating platform, and within the range of typical human accelerations, the Axivity AX6 is a reliable tool for measuring accelerations representative of physical activity. However, further research is necessary to validate its performance under free-living conditions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Electrophysiological characterization of pre‐adolescents born with intrauterine growth restriction: insights from clinical and computational data

  • Bueno-Palomeque, Freddy L.
  • Zacur, Ernesto
  • Pueyo, Esther
  • Crispi, Fàtima
  • Laguna, Pablo
  • Mincholé, Ana
Anatomical changes associated with intra-uterine growth restriction (IUGR) have been observed in different age groups and linked to cardiovascular complications. This study analysed the electrocardiogram (ECG) in pre-adolescents with severe IUGR, comparing QRS complex and T-wave biomarkers with controls. Computer simulations explored links between anatomical re-modelling and ECG biomarkers, providing insights into the potential cardiovascular risk associated with IUGR-induced re-modelling. Clinical recordings were analysed using principal component analysis (PCA) to compute spatially transformed leads, enhancing QRS complex and T-wave delineation for depolarization and repolarization assessment. Transformed leads analysis revealed a 4-ms increase in QRS complex duration (QRS ) and a 2-ms increase in the T peak-to-end interval (T ) in IUGR subjects compared to controls. We conducted electrophysiological in silico simulations using anatomical models based on clinical IUGR data. These models, derived from a reference control, incorporated key geometric changes associated with IUGR, the apex-base length, basal diameter, wall thickness () and ventricular tissue volume, to assess their impact on depolarization and repolarization intervals. In silico PCA leads showed increased QRS , QRS amplitude and T in globular models, consistent with clinical data. Despite the QRS increase, the QT interval increases but is not linearly related to the change. These findings suggest that cardiac re-modelling primarily influences the depolarization cycle, notably QRS , while repolarization intervals increase but are not directly related to the increase. The study highlights the impact of geometric and volumetric changes in IUGR-related cardiac re-modelling, also emphasizing the need for further research on electrophysiological re-modelling and its effects on cardiac function.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Digital monitoring and electronic patient-reported outcomes collection following atrial fibrillation ablation

  • Almeida, João G.
  • Teixeira, Rafael
  • Neves, Inês
  • Carrington, Mafalda
  • Fonseca, Paulo
  • Oliveira, Marco
  • Gonçalves, Helena
  • Primo, João
  • Fontes-Carvalho, Ricardo
  • Barra, Sérgio
  • Martínez, Juan Pablo
  • Almeida, Rute
Background. Atrial fibrillation (AF) remains a challenging condition to manage traditionally in clinical practice, and despite improvements in digital health, its impact on clinical outcomes remains uncertain. Objective. This study aimed to assess the feasibility of a structured digital-blended follow-up for patients undergoing AF ablation, incorporating electronic patient-reported outcome measures (PROMs) while evaluating its impact on the timing of recurrence diagnosis and reintervention. Methods. In this retrospective observational study, we included patients enrolled in a structured 2-year digital program starting in January 2021. This featured a Web platform for physicians to record clinical variables and a patient-centered mobile application to report PROM (Atrial Fibrillation Effect on Quality-of-Life [AFEQT] and Patient-Reported Outcomes Measurement Information System [PROMIS]). Clinical outcomes were compared with those from a retrospective conventionally managed cohort (2017–2020) after propensity score matching (n = 363 per group). Results. Until May 2024, 421 patients were enrolled (mean age: 60.9 years; 33.0% female). Over a median follow-up of 546 days, 64% of the patients used the application monthly, and completeness rates for AFEQT and PROMIS questionnaires were 80% and 50%, respectively. At 12 months, significant improvements were observed for AFEQT and PROMIS scores (cognitive and physical function, anxiety, and depression). Arrhythmia recurrence significantly influenced the rates of changes for AFEQT, depression, and physical function (P < .05 for interactions). Digital follow-up was associated with a shorter time until atrial tachycardia or AF recurrence (hazard ratio 1.45, P = .019) and antiarrhythmic intervention (hazard ratio 1.65, P = .022). Conclusion. Systematic electronic PROM collection after AF ablation is feasible in clinical practice. Structured digital-blended integrated care guarantees continuity of AF management and supports earlier detection and treatment of recurrences
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Tilt-induced changes in f-wave characteristics during atrial fibrillation: an experimental and computational investigation

  • Abdollahpur, Mostafa
  • Celotto, Chiara
  • Sánchez, Carlos
  • Plappert, Félix
  • Östenson, Sten
  • Platonov, Pyotr G.
  • Laguna, Pablo
  • Pueyo, Esther
  • Sandberg, Frida
Introduction This study explores transient and stationary effects of sympathetic and parasympathetic stimulation on f-wave characteristics in atrial fibrillation (AF) patients undergoing a tilt test. Transient phase is defined as the initial 2-minute interval following each postural change, reflecting immediate autonomic adaptation, whereas steady phase refers to the subsequent interval (from 3 minutes post-change until phase end) representing a stable autonomic state. Methods Our primary aim is to investigate how the two branches of the autonomic nervous system (ANS) influence the f-wave frequency time series (f(m)). An analysis of f(m) in terms of the mean over time (Ff) and the magnitude of respiration-modulated f(m) variations (ΔFf) is conducted during baseline supine rest (B), head-down tilt (HDT) and head-up tilt (HUT). We analyzed data from a previous study in which 24 patients with persistent AF underwent a tilt test protocol, during which electrocardiograms (ECGs) were recorded. A model-based method was used to extract f(m) series from the ECG. Subsequently, an orthogonal subspace projection method was employed to quantify ΔFf, considering an ECG-derived respiratory signal. Electrophysiological computational simulations were conducted on 2D and 3D human atrial persistent AF models to aid the interpretation of clinical findings. Various levels of cholinergic stimulation by acetylcholine and β-adrenergic stimulation by isoproterenol were tested in the models. The temporal modulation of acetylcholine, representing changes associated with respiration, was cyclically modeled using sinusoidal waveforms. Results Analysis of the clinical data showed a decrease in Ff from B to HDT and an increase from HDT to HUT. During HDT, ΔFf initially increased in the transient phase before decreasing in the steady phase, then rose again during HUT. Analysis of the simulated data showed that increasing the concentration of Isoproterenol and/or acetylcholine resulted in a rise in Ff. Additionally, the magnitude of ΔFf was shown to be associated with the extent of acetylcholine fluctuation. Discussion These results suggest that changes in f-wave frequency characteristics during HUT and HDT could be linked to changes in sympathetic activity, with parasympathetic activity possibly modulating the effects of sympathetic activity rather than being an independent driver of fibrillatory rate changes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A simple blood biomarker based on gene expression describes cardiovascular health-related biological age

  • Hernández-Bellido, Natalia
  • Hernández-Vicente, Adrián
  • García-Mendívil, Laura
  • Ramos-Marquès, Estel
  • Hernando, David
  • Cebollada, Alberto
  • Köhler, Ralf
  • Garatachea, Nuria
  • Pueyo, Esther
  • Ordovás, Laura
Abstract The need to monitor the aging process as a risk factor for disease and mortality beyond chronological age (CA) has led to numerous investigations into the estimation of the biological age (BA) of individuals. However, the accuracy of BA estimation tools is often judged by their ability to approximate CA, questioning their value in capturing the variance in health status and thus correctly estimating BA. Their biological relevance is often assessed in relation to health outcomes or mortality, underexploiting their potential for real-time monitoring of BA. Furthermore, their complexity may limit their clinical translation to large populations. Here, we describe the gene expression-based age monitoring Clock (GamC), a simple biomarker of aging (BOA), and characterize its biological relevance with synchronous cardiovascular (CV) health-related functional data. GamC is calculated from the expression levels of three genes consistently dysregulated with age in blood (ABLIM1, CCR7, and LEF1). GamC shows moderate but reliable association with CA in three independent cohorts, supported by transcriptome-wide changes. It demonstrates specialized biological meaning, as it specifically describes current physical activity levels, but poorly correlates with autonomic nervous system function, both age-related factors associated with CV health. Finally, it expresses BA monitoring capacity by modestly responding to an effective exercise-based intervention in centenarians. In conclusion, GamC is proposed as a simple and affordable candidate BOA for reporting the individuals’ current CV health-related BA, thus promoting its broad translation and application into measures aimed at promoting healthy aging in relation to CV health, the leading cause of death worldwide.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optical fiber integration in PDMS devices for dynamic tissue deformation

  • Velarte, Antonio
  • Sannino, Andrea
  • Otin, Aranzazu
  • Santamaría, Beatriz
  • Artigas, José Ignacio
  • Pueyo, Esther
This study introduces an advanced optical fiber-based stretchable sensing platform designed for precise biomechanical characterization in tissue engineering applications, specifically tailored for cardiac tissue studies. The system is entirely fabricated from biocompatible polydimethylsiloxane (PDMS) material, and features a thin upper membrane and an internal cavity where controlled pneumatic deformation occurs. Deformation is quantified through changes in optical intensity measured through a strategically aligned optical fiber pair, as membrane stretching disrupts total internal reflection conditions. Finite element modeling using COMSOL is used to optimize device geometry and predict deformation, which is subsequently validated through experimental analyses. A custom-designed electronic system with capacity for real-time signal processing ensures stable and sensitive data acquisition. The experimental results show high levels of linearity and repeatability in a physiologically relevant stretch range, highlighting its potential for biomechanical research applications and dynamic tissue stimulation. Future improvements are directed toward extending the reliable deformation operating range through advances in the optical system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Resistance Exercise Intervention Restores Functional Capacity and Improves Frailty Biomarkers in Centenarians

  • Marcos-Perez, Diego
  • Hernandez-Vicente, Adrián
  • Cruces-Salguero, Sara
  • Landa, Jon
  • Bonvini, Michelle
  • Vicente-Rodríguez, German
  • Pueyo, Esther
  • Rodriguez-Mañas, Leocadio
  • Abizanda, Pedro
  • Otaegui, David
  • Garatachea, Nuria
  • Matheu, Ander
Background: Centenarians comprise an age group characterized by exceptional longevity and low age-associated pathologies. However, they still experience physiological decline, and different studies have linked frailty to this population. Exercise interventions reverse frailty and improve functional capacity, but no studies have addressed the effect of an intervention in centenarians. In this study, we assessed the impact of a 12-week resistance exercise intervention in a group of centenarians and characterized their functional capacity as well as the expression of several molecular biomarkers associated with frailty. Methods: A total of 19 centenarians were enrolled, but 7 of them did not complete the study. The remaining 12 centenarians were randomly assigned to the control or intervention group, which was a 12-week resistance exercise intervention. Molecular biomarkers were measured by qRT-PCR and ELISA. Results: The intervention group improved their functional capacity measured by Short Physical Performance Battery (SPPB) (post 5.0 vs 2.3 in pre) and Physical Performance and Mobility Examination (PPME) (6.5 vs 3.8), as well as in frailty status studied by Fried Frailty Phenotype (3.0 vs 3.8) and Frailty Trait Scale 5 (FTS5) (post 30.7 vs 34.0 in pre) scales. ANCOVA revealed that the resistance training led to significant improvements in functional capacity scales SPPB (p = 0.01) and PPME (p < 0.001), as well as Fried Frailty Phenotype (p = 0.001) and FTS5 (p = 0.05). Biomarkers related to frailty (EGR1, miR194-5p, miR125b-5p and miR454-3p) and inflammation (IL-6 and IL-1β) showed different expression patterns in centenarians (n = 19) compared to both old (n = 44, average of 79 years old) and young adults (n = 34, average of 29 years old) groups. Notably, the intervention was associated with improvements in frailty and inflammation biomarkers expression. Finally, correlation analyses showed significant associations between all functional and frailty variables, with SPPB correlating with miR454-3p (ρ = 0.73) and FTS5 correlating with miR454-3p (ρ = −0.83), IL-6 (ρ = 0.60) and miR125b-5p (ρ = −0.55). Conclusions: Our results revealed that resistance exercise intervention enhances functional status and reduces frailty in centenarians, and this is associated with improvements in frailty and inflammation biomarkers.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Deep Learning for analyzing chaotic dynamics in biological time series: Insights from frog heart signals

  • Mayora-Cebollero, Carmen
  • Fenton, Flavio H.
  • Halprin, Molly
  • Herndon, Conner
  • Toye, Mikael J.
  • Barrio, Roberto
The study of experimental data is a relevant task in several physical, chemical and biological applications. In particular, the analysis of chaotic dynamics in cardiac systems is crucial as it can be related to certain pathological arrhythmias. When working with short and noisy experimental time series, some standard techniques for chaos detection cannot provide reliable results because of such data characteristics. Moreover, when small datasets are available, some Deep Learning techniques cannot be applied directly (that is, using part of the data to train the network, and using the trained network to analyze the remaining dataset). To overcome all these limitations, we propose an automatic algorithm that combines Deep Learning and some selection strategies based on a mathematical model of the same nature of the experimental data. To demonstrate its performance, we test it with experimental data obtained from ex-vivo frog heart experiments, achieving highly accurate results.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Non-Linear Modeling and Analysis of Amplifier-Less Potentiostat Architectures

  • Sannino, Andrea
  • Wiens, David-Peter
  • Ortmanns, Maurits
  • Artigas, José I.
  • Otín, Aránzazu
In this article, a previously published amplifier-less potentiostat architecture is further examined. Starting with a linearized model, the impact of the most important parameters is studied taking in account the electrodes-solution electrochemical interface. A detailed model is obtained and thoroughly verified, and recommended operating conditions are given for certain limit load conditions. Then, a more complete non-linear model is developed to take in account the measurement uncertainty introduced by the circuit non-linear components. This non-linear model is compared to a time domain description of the circuit and it is verified that it can predict the non-linear behavior with a precision better than 20%. This result enables the circuit designers to compensate for these effects and ultimately reduce the overall measurement uncertainty.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effects of concurrent training on atrial fibrillation burden, fitness and physical activity after pulmonary vein isolation: Study protocol for a randomized controlled trial

  • Echevarría-Polo, Marcos
  • Hernández-Vicente, Adrián
  • Vadillo-Martín, Pablo
  • Sanchis-Gomar, Fabian
  • Melero-Polo, Jorge
  • Cabrera-Ramos, Mercedes
  • Montilla-Padilla, Isabel
  • Rucco, Andrea
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Pueyo, Esther
  • Ramos-Maqueda, Javier
  • Garatachea, Nuria
Background: Pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF), but many patients remain inactive after the procedure for fear of AF recurrence. Evidence supports moderate exercise to improve outcomes of this procedure; however, there are no clear guidelines for returning to physical exercise after PVI. We aim to evaluate the effects of a combined endurance and resistance training (CT) intervention on cardiac function, physical fitness, activity levels, body composition, quality of life, and AF burden after PVI. Methods and results: We will conduct a randomized controlled trial with 68 participants, approximately 15 months after PVI, randomized 1:1 to a CT or control group. The CT program consists of supervised training sessions combining moderate-intensity endurance and resistance work three times a week for 12 weeks. Outcomes will be assessed at three time points: at baseline, after the intervention, and after 12 weeks of follow-up, including echocardiographic and electrocardiographic parameters, fitness tests, physical activity monitoring, body composition, health-related quality of life, and AF burden monitored by an implantable cardiac Holter. We expect that CT intervention will improve cardiac function, increase physical fitness and activity levels, optimize body composition, and improve quality of life without recurrence of AF. Conclusions: This protocol is the first to examine the effects of return to exercise training in AF patients after PVI using objective monitoring tools. The simplicity and scalability of the intervention support its safe integration into clinical practice to promote physical activity and improve patient outcomes after PVI.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sudden cardiac death risk prediction from QT–RR adaptation time lag computed from exercise stress test ECG

  • Pérez, Cristina
  • Martínez, Juan Pablo
  • Ramírez, Julia
  • Kenttä, Tuomas
  • Junttila, Juhani
  • Kiviniemi, Antti
  • Perkiömäki, Juha
  • Huikuri, Heikki
  • Pueyo, Esther
  • Laguna, Pablo
Objetive: This study aims to evaluate the QT adaptation time following gradual heart rate changes estimated from exercise stress test (EST) ECGs as a marker of sudden cardiac death (SCD) risk. The predicted risk value for any cardiovascular death (CVD) is also evaluated. Methods: Three ECG-derived markers related to QT-RR adaptation time were estimated during the exercise phase of EST, τe, during the recovery phase, τr, and as the difference between them, Δτ. The values were computed from patients with coronary artery disease (CAD) from ARTEMIS study (N=1472; median follow-up of 8.9 years). These markers are calculated as the delay between the observed RR interval series and a patient-specific memoryless RR series computed from the QT interval (RR-based strategy). Alternatively, the estimates were calculated as the delay between the observed QT intervals and a patient-specific instantaneous QT series computed from the RR intervals (QT-based strategy). The relation between the markers and CAD or SCD was evaluated. Results: The marker τr is more robustly estimateed with the RR-based strategy and is able to stratify survivors and victims of either SCD or CVD (p-value equal to 0.022 and 0.065, respectively). Multivariable regression models for predicting SCD and CVD include the QT-RR adaptation time estimated in the recovery phase of EST using the RR-based strategy. Conclusion: A prolonged QT-RR adaptation time during the recovery phase of the EST ECG, calculated with the RR-based strategy, can predict SCD and CVD, providing complementary information to other clinical markers
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

An Improved Discrete Time Amplifier-Less Potentiostat Architecture for Metabolic Sensing Applications

  • Sannino, Andrea
  • Artigas, José I.
  • Otín, Aránzazu
In this paper, an improved discrete-time potentiostat architecture is proposed. The focus is placed on the digital controller, aiming to enhance its performances, reduce measurement uncertainty and increase speed. The system is modeled including its non-linear behavior, and the impact of the digital controller parameters on the system response is analyzed through behavioral simulations. The developed mathematical model shows good agreement with the simulation results. The new controller successfully reduces the measurement uncertainty compared to a purely integral control system by up to a factor of 100 in the worst-case scenario. The system speed is also improved by approximately 40%. The new digital controller not only improves the overall performance of the system, but also does not increase significantly the hardware complexity of the system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Continuous smartwatch monitoring after atrial fibrillation ablation: feasibility of burden estimation and association with quality of life

  • Almeida, João G.
  • Dias, Duarte
  • Silva-Teixeira, Rafael
  • Carrington, Mafalda
  • Fonseca, Paulo
  • Oliveira, Marco
  • Gonçalves, Helena
  • Primo, João
  • Fontes-Carvalho, Ricardo
  • Azevedo, Luís
  • Barra, Sérgio
  • Martínez, Juan Pablo
  • Almeida, Rute
Introduction: Continuous atrial fibrillation burden assessment is clinically relevant but often limited by the invasiveness of current tools. Wearables offer a non-invasive alternative, but evidence in the post-ablation setting is limited. We assessed the feasibility of smartwatch-based atrial fibrillation burden quantification after catheter ablation and its association with quality of life. Methods: In this prospective, single-centre study, patients undergoing atrial fibrillation ablation entered a 12-month digital follow-up program using a smartwatch (daily electrocardiogram recommended). Atrial fibrillation burden was defined as the percentage of monitored days with atrial fibrillation-detected electrocardiograms. A Bayesian multivariable model examined the association between atrial fibrillation burden and quality-of-life score (AFEQT). Results: Twenty patients (mean age 52.6 ± 10.3 years; 10% female) were enrolled. Over 12 months, 3,604 electrocardiograms were collected (mean 180 per participant); atrial fibrillation was detected in 55%. Electrocardiograms were submitted on 36% of days. Median atrial fibrillation burden was 1.4% (range: 0%–25%). AFEQT improved significantly over time (+1.71 points/month; 95% Credible Interval: 0.78–2.65), with 69% achieving a clinically meaningful improvement. Unlike atrial fibrillation recurrence, higher atrial fibrillation burden was associated with smaller AFEQT gains (interaction estimate: −0.23; 95% Credible Interval: −0.40 to −0.06). Each 1% increase in atrial fibrillation burden corresponded to an estimated 2.8-point lower AFEQT at 12 months. Conclusion: Smartwatch-based monitoring of atrial fibrillation burden is feasible after ablation. Higher atrial fibrillation burden was associated with reduced improvement in quality of life, supporting its value as a patient-centred outcome metric.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Stress Detection Using Heart Rate Variability and Respiratory Signals Derived From a Single-Lead ECG

  • Jiménez-Ocaña, Alvaro A.
  • Pantoja, Andrés
  • Armañac, Pablo
  • Bailón, Raquel
  • Laguna, Pablo
  • Giraldo, Luis Felipe
Stress detection is a widely studied field due to its significant implications for mental and physical health. While multimodal approaches show promising results, they present challenges related to hardware constraints and computational requirements that limits real time implementation in wearable devices. We propose a hybrid methodology combining feature extraction with ma chine learning (ML) for stress detection, using exclusively single-lead electrocardiogram (ECG) signals from which heart rate variability (HRV) and respiratory signals with their derived features are extracted. We evaluated our approach using the ES3 project database, testing various feature combinations with the XGBoost model. Results demonstrate that incorporating ECG-derived respiratory features significantly improves classification accuracy and computational efficiency compared to traditional HRV-based approaches and deep learning models. Feature importance analysis identified a reduced set of key features, resulting in a more efficient model with superior performance and substantially lower inference times than deep learning models. These findings support the feasibility of acute stress detection using a single-lead ECG-based multimodal approach that combines feature extraction with ML techniques, providing insights into stress-induced physiological responses and contributing to more accessible biomedical monitoring strategies.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Bregman Proximal Gradient with extrapolation to train a Reservoir Computing network for a binary classification task

  • Mayora-Cebollero, Carmen
  • Mayora-Cebollero, Ana
  • Lozano, Álvaro
  • Barrio, Roberto
This study examines the training process of Artificial Neural Networks, specifically focusing on Reservoir Computing and on binary classification tasks. Training involves optimizing the network’s parameters to minimize the error of a loss function, which quantifies the discrepancy between network outputs and target data. Several numerical optimizers are used in the literature. Here, we formulate the supervised learning problem using the recently introduced Bregman Proximal Gradient with extrapolation (BPGe) algorithm for non-convex optimization problems. We compare this new method with the classical Stochastic Gradient Descent (SGD), the Root Mean Square Propagation (RMSProp), the Adaptive Moment Estimation (Adam), and two variants with Nesterov momentum (NAG and NAdam). The new approach leads to an accurate and significantly faster numerical algorithm for solving supervised learning problems on binary classification tasks in Reservoir Computing. Three test examples are presented, one based on chaotic data classification in the classical Lorenz system, another on the Human Activity Recognition (HAR) using smartphones dataset for movement–rest classification, and the last one on the MNIST dataset for even–odd classification. We show that our approach is highly competitive with existing methods in the tests performed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A modular soft core-based system for affordable acquisition and processing of electrophysiological recordings

  • Velarte, Antonio
  • Castel, Antonio
  • Otin, Aranzazu
  • Olivan-Viguera, Aida
  • Pueyo, Esther
Flexible low-cost platforms for high-fidelity recording of biological signals are essential to advance health monitoring applications, yet they often rely on proprietary hardware that is resource-intensive and expensive. This study introduces a cost-effective FPGA platform that embeds an ARM Cortex M1 soft core processor with custom logic for signal acquisition, signal conditioning, artifact suppression, and data management, which is built around an Intan RHD2000 headstage. On-chip routines perform automatic offset calibration and gain calibration to ensure measurement fidelity. A graphical user interface, co-developed with biomedical end users, ensures compliance with data rate and timing constraints, enables live visualization, and streamlines parameter configuration. Bench validation using a multichannel test generator reproducing cardiac field potentials up to  ± 2 mV and bandwidths up to 5 kHz demonstrated stable timing, low crosstalk, and accurate amplitude reconstruction. Platform performance matches that of commercial multielectrode array systems, with minor deviations attributed to interconnection effects. Together, these results provide an accessible and extensible platform that preserves measurement fidelity while lowering the barrier to adoption in resource constrained laboratories.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Integrated multi-modal data analysis for computational modeling of healthy and location-dependent myocardial infarction conditions in porcine hearts

  • Rosales, Ricardo M.
  • Wu, Ming
  • Claus, Piet
  • Janssens, Stefan
  • Ríos-Muñoz, Gonzalo R.
  • Fernández-Santos, María Eugenia
  • Martínez-Legazpi, Pablo
  • Bermejo, Javier
  • Flanagan, Aiden
  • Doblaré, Manuel
  • Mincholé, Ana
  • Pueyo, Esther
Porcine hearts are widely used for preclinical cardiac evaluation. Computational models, by effectively integrating comprehensive experimental data, often reinforce this preclinical assessment. Using extensive multi-modal data, we developed swine ventricular digital twins for healthy and chronic myocardial infarction (MI) conditions to investigate the roles of the cardiac conduction system (CS), spatial repolarization heterogeneities, cardiomyocyte orientation, cell-to-cell coupling, and MI characteristics on ventricular function. We analyzed cardiac magnetic resonance (CMR) images, electrocardiograms (ECGs), and optical (OM) and electroanatomical mapping from 5 healthy and 10 MI pigs. CS architectures were built from OM and ECG recordings. Myocardial fiber orientation, action potential characteristics, and cell-to-cell conductivity in MI tissue were defined from OM and CMR data. Simulated ECGs for healthy and MI models of left anterior descending and left circumflex occlusions were compared to experimental ECGs and were used to assess MI-induced changes. Subject-specific fiber orientation calibration minimally affected electrophysiology, with conduction velocity (CV) and action potential duration (APD) changing by less than 3.6% with respect to standard orientation. Accurate CS and repolarization heterogeneities reproduced depolarization (Pearson correlation 0.76 for QRS) and repolarization (Pearson correlation 0.74 for T-wave) patterns. Incorporating experimentally guided MI-induced alterations enabled the replication of MI depolarization and repolarization features (relative errors: 0.5% CV, 2.9% APD), yielded realistic T-wave morphologies (0.63 Pearson correlation), and revealed ECG patterns specific to vessel-dependent occlusions. Thus, by integrating extensive multi-modal data, we advance porcine cardiac digital twins and demonstrate the influence of key structural and electrophysiological parameters on healthy and MI heart function, providing a robust computational framework for mechanistic and translational applications.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Real-time assessment of inter and intraventricular synchrony in cardiac resynchronization therapy with left bundle branch pacing using ECGi and low-frequency QRS analysis

  • Sales-Belles, Clara
  • Mincholé, Ana
  • Cabrera-Ramos, Mercedes
  • Melero-Polo, Jorge
  • Pueyo, Esther
  • Ramos Maqueda, Javier
Introduction: Left bundle branch pacing (LBBP) is an alternative to conventional biventricular pacing for cardiac resynchronization therapy (CRT). Methods: A 76-year-old male was referred for CRT via left bundle branch pacing (LBBP). We present the real-time characterization of the transition from intrinsic left bundle branch block (LBBB) to sequential pacing modalities: right ventricular septal pacing (RVSP), left ventricular septal pacing (LVSP), and finally LBBP. Epicardial activation maps from electrocardiographic imaging (ECGi) and low-frequency (LF) QRS analysis were used to provide complementary insights into interand intraventricular synchrony. Results: LVSP, LBBP, and anodal capture improved activation compared with baseline, with LBBP achieving the greatest improvements in interventricular and LV intraventricular synchrony despite higher RV dispersion. Conclusion: These findings highlight ECGi and LF QRS as valuable tools to guide CRT.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Ventricular activation and repolarization in response to physiological and conventional pacing using ultra-high-frequency electrocardiography

  • Palacios, Saúl
  • Smisek, Radovan
  • Curila, Karol
  • Nguyen, Uyen
  • Prinzen, Frits W.
  • Halamek, Josef
  • Plesinger, Filip
  • Jurak, Pavel
  • Ramos, Javier
  • Martínez, Juan Pablo
  • Pueyo, Esther
Background: Physiological pacing targeting the cardiac conduction system is increasingly being adopted as an alternative to conventional right ventricular (RV) pacing for the treatment of bradyarrhythmias, although its effects on ventricular repolarization remain underexplored. Objective: This study evaluates depolarization and repolarization responses to different pacing techniques using ultra-high-frequency electrocardiograms (UHF-ECGs). Methods: Temporary pacing was performed at different cardiac areas in 178 patients with bradycardia. Depolarization was assessed via QRS duration (QRSd), QRS area (QRSa), ventricular dyssynchrony (e-DYS), and activation time dispersion (dAT computed from leads V1-V6 and dAT4-6 from leads V1-V6). Repolarization was analyzed using the corrected QT interval (QTc), T-wave area (Ta), Periodic Repolarization Dynamics (PRD), and repolarization time dispersion (dRTc and dRTc4-6). Results: His bundle pacing (HBP) preserved ventricular activation patterns similar to spontaneous rhythm. Left bundle branch pacing (LBBP) induced moderate depolarization changes, primarily due to delayed right ventricular activation, while maintaining left ventricular synchrony. In particular, dAT showed no significant differences between HBP and spontaneous rhythm, while differences between LBBAP and spontaneous rhythm were significant but below 7 ms in median. When restricted to the left ventricle (LV), no significant differences in dAT4-6 were found between LBBAP and spontaneous rhythm. Importantly, e-DYS for HBP showed similar values to spontaneous rhythm, LBBP led to a significant reduction (median differences approximately 20 ms), and RVP was associated with a significant increase (above 15 ms in median). In line with these results, QRSd and QRSa showed the largest values for RVP. In terms of ventricular repolarization, median differences in the QTc interval between pacing modes and spontaneous rhythm were below 3 ms for HBP, above 1 ms for LBBP, and above 20 ms for RVP. All pacing modes led to a reduction in PRD, with the most marked reductions observed for LBBP, particularly for selective LBBP, with median changes with respect to spontaneous rhythm of 4.6 degrees. RT and RTc showed similar trends for all pacing techniques. Ta, however, showed median differences with respect to spontaneous rhythm above 100 and 34 µ Vs when pacing the RV at the apex and the septum, respectively, whereas such median differences were below 16µ Vs for HBP and below 2 µ Vs for LBBP. Conclusion: Physiological stimulation via HBP or LBBAP generates ventricular depolarization and repolarization responses that more closely resembles that of spontaneous rhythm, in high contrast to the largely different response induced by RV pacing. HBP and LBBAP have distinct technical characteristics, including differences in capture thresholds, lead stability, and procedural aspects. These techniques serve as alternatives to conventional RV pacing.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

T-wave Peak-to-End Changes, Quantified by Time-Warping, Surrogates Ventricular Repolarization Dispersion for Ventricular Fibrillation Prediction in a Porcine Myocardial Infarction Model

  • Gómez, Neurys
  • Abramochkina, Alena S.
  • Ramírez, Julia
  • Ovechkin, Alexey O.
  • Bernikova, Olesya G.
  • Platonov, Pyotr G.
  • Azarov, Jan E.
  • Laguna, Pablo
  • Martínez, Juan Pablo
Background: Ventricular fibrillation (VF) during acute ischemia is linked to increased dispersion of ventricular repolarization (DOR), which is considered a robust marker of arrhythmic susceptibility. In previous works, we showed that a time-warping-based index quantifying morphological changes from the T-wave peak to the T-wave end over a PCA transform lead, dPCAw,Tpe, outperformed the T-peak-to-T-end interval (Tpe) in arrhythmic risk prediction in a closed-chest porcine infarction model. In this study, we compare dPCAw,Tpe with the DOR measured in an open-chest porcine infarction model, to test the hypothesis that dPCAw,Tpe is a noninvasive surrogate for DOR, investigating its predictive value for VF occurrence. Methods: Myocardial ischemia was induced by coronary ligation in 55 domestic pigs. Surface ECG and intramyocardial electrograms were recorded simultaneously. DOR was computed as the range of the end-of-repolarization times across intramyocardial electrograms, while dPCAw,Tpe was extracted from Tpe morphology, measured in a spatially transformed PCA lead and using a warping-based approach. Additionally, the classical Tpe interval was computed as a reference. Indices were compared between pigs developing delayed VF (Delayed-VF group) and those who did not (Non-VF group). Results: dPCAw,Tpe, DOR and Tpe remained stable at baseline but showed progressive changes during ischemia, with larger changes in animals that developed VF. At 5, 10, and 15 minutes after occlusion, ROC analysis showed significant discriminatory capacity, with AUC values consistently ≥0.79 for all indexes and an early predictive value with AUC of 0.870 for dPCAw,Tpe at 5 minutes, accompanied by balanced sensitivity and specificity values. Cox regression for VF risk prediction resulted in hazard ratios ranging from 5.86 to 11.95 across time points. Kaplan-Meier survival curves stratified by ROC-derived thresholds showed significant separation between groups at all three time points. Linear regression analyses between dPCAw,Tpe and DOR showed consistent correlation in VF-susceptible animals (median R2=0.33). This association was stronger than that observed between Tpe and DOR (median R2=0.16). Conclusions: The time-warping-based index, dPCAw,Tpe, is a reliable non-invasive surrogate of DOR, with comparable predictive value for delayed VF risk under ischemic conditions, providing earlier and more robust prediction than the Tpe index. These findings highlight their translational potential and require validation in human cohort studies.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Risk Stratification of Patients With Type 2 Long‐QT Syndrome Through Analysis of T‐Wave Morphology

  • Gómez, Neurys
  • Ramírez, Julia
  • Savelev, Aleksei A.
  • Dahlberg, Pia
  • Svensson, Anneli
  • Larsson, Nina
  • Ljungström, Erik
  • Chaudhry, Uzma
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Platonov, Pyotr G.
BACKGROUND: Risk stratification in type 2 long-QT syndrome remains challenging, as QT duration may not fully reflect all underlying arrhythmic vulnerability. We assessed whether an index derived from the T-wave morphology is associated with cardiac events in a cohort with type 2 long-QT syndrome. METHODS: We retrospectively and prospectively analyzed 54 genotype-confirmed patients with type 2 long-QT syndrome. T-wave morphology in 8 independent leads was assessed using a warping-based index, the T-wave morphology variation (TMV) index, quantifying T-wave morphologic changes from a general population-based reference T-wave. Association with the first lifetime occurrence of a cardiac event, including either syncope or the combined ventricular arrhythmia end point, was tested using univariate and multivariable Cox regression models. RESULTS: Using the 25th-percentile threshold (TMV≤−18.41 ms), more negative TMV values indicating greater morphologic changes and a broader or delayed repolarization phase in the T-wave signal relative to the control, as observed in lead I, were significantly associated with increased risk of cardiac event (hazard ratio [HR], 3.505 [95% CI, 1.673–7.341]; P<0.001). The association remained significant after adjustment for corrected QT (HR, 2.92 [95% CI, 1.111–7.676]; P=0.03) and after additional adjustment for sex (HR, 3.375 [95% CI, 1.256–9.067]; P=0.016), and the T-wave morphology combination score (HR, 4.061 [95% CI, 1.369–12.046]; P=0.012). CONCLUSIONS: T-wave morphology abnormalities, quantified using TMV, are associated with a higher risk of cardiac events after adjustment for corrected QT prolongation, sex, and morphology combination score. TMV could complement current risk stratification strategies, although confirmatory validation in larger, independent, prospective cohorts is pending.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Functional recruitment and regulatory mechanisms of SK channels in patients with early stages of ventricular remodeling

  • Pérez-Martínez, Alba
  • López-Andrés, Cristina
  • García-Mendívil, Laura
  • López-Yus, Marta
  • Batín, Diana
  • Vallejo-Gil, Jose M.
  • Fañanás-Mastral, Javier
  • Vázquez-Sancho, Manuel
  • Matamala-Adell, Marta
  • Sorribas-Berjón, Juan F.
  • Bellido-Morales, Javier A.
  • Ballester-Cuenca, Carlos
  • Arbonés Mainar, Jose M.
  • Pueyo, Esther
  • Oliván-Viguera, Aída
Aims Small-conductance Ca2+-activated potassium channels (SK) are increasingly investigated as therapeutic targets for atrial fibrillation. Emerging evidence, however, indicates their functional relevance in ventricular pathologies. This study investigates the expression, localization, and functional role of SK2 and SK3 channel subtypes in ventricular myocardium from patients with and without valvular disease-associated remodeling. Methods and results Human ventricular tissue was obtained from 125 patients undergoing cardiac surgery. mRNA levels of KCNN2 and KCNN3 were quantified with RT-qPCR. Protein levels and localization of SK2 and SK3 were analyzed via immunohistochemistry. Functional responses were evaluated by optical mapping of living ventricular myocardial slices. Gene expression was not significantly altered in remodeled myocardium. SK2 and SK3 were located in striated patterns, colocalizing with L-type Ca2+ channels in all patients. SK3 was also present at intercalated discs, although this pattern was significantly reduced in remodeled myocardium. Functionally, SK channels were inactive in non-remodeled myocardium, with neither apamin nor SKA-31 altering action potential duration (APD). In contrast, in remodeled myocardium, apamin prolonged and SKA-31 shortened APD. This response to SKA-31 was more pronounced in patients with reduced ejection fraction. Mechanistically, SKA-31 effects were abolished by L-type Ca2+ channel blockade or CaMKII inhibition, but not by PKA inhibition, suggesting that SK activation is Ca2+ and CaMKII-dependent. Conclusions SK channels become functionally upregulated in the early stages of ventricular remodeling despite the absence of gene expression changes. SK activation might rely on post-translational modifications and calcium handling alterations. These findings highlight the need for caution in targeting SK channels therapeutically.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Fabrication and integration of partially-transparent ionic polymer–metal composite actuators into microphysiological systems

  • Tajeddin, Alireza
  • Velarte, Antonio
  • Sattari, Romina
  • Wiendels, Maury
  • Hunt, Andres
  • Mummery, Christine L.
  • Orlova, Valeria
  • Zhang, Juan
  • Portero, Vincent
  • Pueyo, Esther
  • Otín, Arantxa
  • Mastrangeli, Massimo
We present partially-transparent ionic polymer–metal composite (IPMC) actuators and their seamless integration into microphysiological systems, to enable dynamic mechanical stimulation of cell monolayers with direct optical access. The proposed IPMC platform employs a layered microfabrication strategy that allows precise tailoring of electrode geometry while preserving optical transparency across selected regions of the actuator. This design overcomes a key limitation of conventional IPMCs, namely their inherent opacity and resulting lack of (bio-)opto-mechatronics compatibility, thereby facilitating in vitro applications and real-time optical and fluorescent microscopy. The actuators are integrated into standard 12-well culture plates through customized mechanical and electrical interfaces and are driven by a compact, programmable electronic control system, enabling flexible modulation of actuation dynamics within biologically-relevant regimes. We confirm the biocompatibility of the platform by culturing Human Embryonic Kidney (HEK) cells and contractile cardiomyocytes from human-induced pluripotent stem cells (hiPSC-CMs). Together, these advances establish a scalable, low-voltage, and optically-compatible actuation platform for organ-on-chip and mechanobiology applications.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Performance comparison of parameters characterizing P wave variability before the onset of atrial fibrillation

  • Noriega, M.
  • Moreno, C.
  • Martín-Yebra, A.
  • Platonov, P.G.
  • Savelev, A.
  • Marta, J.
  • Martínez, J.P.
  • Sörnmo, L.
  • Laguna, P.
Short-term characterization of P waves occurring before the onset of atrial fibrillation (AF) is essential to better understand triggering mechanisms. The characterization is challenged by a low signal-to-noise ratio which makes P wave delineation difficult. This study compares the performance of a parameter characterizing P wave morphological variability (MV) to that of four previously published P wave variability parameters: amplitude dispersion, duration, arc length, and power ratio of principal components. The comparison is based on the St.Petersburg Atrial Fibrillation Database comprising 176 one-hour sinus rhythm segments just before AF onset, obtained from 32 patients. Following a linear, spatial transformation that emphasizes the P wave, the MV parameter is computed in consecutive, overlapping subsegments and normalized by a reference value taken one hour before AF onset. The results show that the MV parameter exhibits the highest reactivity to AF onset, with a mean relative increase of 19% 10 min before AF onset, whereas the other four parameters had lower reactivities (amplitude dispersion: 10%, duration: 0%, arc length: 10%, and power ratio: 2%). The conclusion is that the MV parameter better reflects the short-term instability of the atrial substrate than the other parameters.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Human in silico modeling guided by transcriptomics predicts drug-induced proarrhythmicity as a function of age

  • Garrido-Huéscar, Elisa
  • Rosales, Ricardo Maximiliano
  • Pérez Zabalza, María
  • Laguna, Pablo
  • Ordovás, Laura
  • Pueyo, Esther
Background and Objective Unexpected cardiotoxicity is a major cause of drug failure during development and can also contribute to market withdrawal. Traditional preclinical models and clinical trials do not fully capture age-related cardiac functional decline, which is associated with increased arrhythmic risk. We aimed to develop human-based in silico electrophysiology models incorporating age-related remodeling to improve the assessment of age-dependent drug-induced cardiotoxicity during drug development. Methods Biological and chronological transcriptomic age-related human ventricular ionic remodeling was integrated into the O’Hara-Virag-Varro-Rudy model of ventricular electrophysiology at both cellular and tissue levels. Cardiac biological age was represented using two independent gene expression-based indices: SenesAge, based on one senescent gene, and AppAge, based on nearly 2,000 age-related genes. A panel of 12 reference drugs was used to evaluate age-related drug-induced cardiotoxicity. Results In silico aging based on SenesAge and AppAge reproduced age-related electrophysiological phenotypes at the cellular, tissue, and ECG levels more closely than chronological age-based remodeling. Biological age-related remodeling also increased the susceptibility to arrhythmogenic events following drug exposure by more than fivefold with respect to the adult population across the majority of tested conditions, although the effects varied according to the drug and its concentration. Conclusions This study provides a novel perspective for incorporating biological age-related remodeling into an established human-based in silico framework for preclinical cardiotoxicity evaluation at the population level. Our findings support biological age-based modeling as a complement to chronological age-based approaches for improving age-specific drug-induced cardiac risk assessment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Single-lead ECG biomarkers for cardiovascular and mortality risk prediction

  • Attali, Lisa
  • Solewicz, Yosef
  • Brimer Biton, Shany
  • Hamami, Hagai
  • Zvuloni, Eran
  • Green, Ilan
  • Laufer, Izhar
  • Laguna, Pablo
  • Martín-Yebra, Alba
  • Martínez, Juan Pablo
  • Almog, Ronit
  • Behar, Joachim A
Objective. Cardiovascular disease remains one of the leading causes of morbidity and mortality worldwide, highlighting the need for accurate risk prediction. Atrial fibrillation burden (AFB), premature ventricular contraction burden (PVCB), and T-wave alternans (TWA) have been individually associated with adverse outcomes. We hypothesized that these three digital ECG biomarkers provide complementary prognostic information for major cardiovascular endpoints and all-cause mortality (ACM), and developed a machine learning approach combining these biomarkers for risk prediction. Approach. We analyzed 81 362 Holter recordings from 54 395 individuals across 20 primary care centers in Israel. A random forest model using AFB, PVCB, TWA, and age was trained to predict 5 year risk of heart failure (HF), ischemic stroke (IS), and ACM. Main results. On the test set, best AUROCs were for HF 0.75 [95% CI: 0.74–0.77] (), for IS 0.69 [0.66–0.71] (), and for ACM 0.79 [0.77–0.80] (). Combining the three ECG-derived biomarkers showed complementary predictive value and improved discrimination by up to 10% over age alone in individuals aged years. Significance. AFB, PVCB, and TWA contribute complementary prognostic information for risk stratification. When combined with age, these biomarkers improve predictive performance compared with age alone.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

T-wave peak-to-end morphology restitution as biomarker in Brugada syndrome

  • Gómez, Neurys
  • Ramírez, Julia
  • Isabel Roquero, Alba
  • Palmieri, Flavio
  • Arbelo Lainez, Elena
  • Mártinez, Juan Pablo
  • Laguna Lasaosa, Pablo
Brugada syndrome (BrS) is a genetic disorder that affects the ion channels of the cardiac myocites, resulting in a higher predisposition to malignant ventricular arrhythmias and sudden cardiac death (SCD). Risk stratification and management of BrS patients remains a major clinical challenge. In this work, we use a time-warping-based index of the T-wave peak-to-end morphological restitution (TPEMR) to quantify the restitution properties of the late phase of ventricular repolarization and evaluate its ability to distinguish between control and BrS patients and between symptomatic (BrS-S) and asymptomatic patients (BrS-A). 24-hour Holter ECG recordings from 89 BrS patients (29 asymptomatic, BrS-A, and 60 symptomatic, BrS-S) and 32 healthy control patients were analyzed. The original, unweighted \(\mathrm{TPEMR}_{O}\) as well as weighted versions with two different strategies \(\mathrm{TPEMR}_{W1}\) and \(\mathrm{TPEMR}_{W2}\) are computed. \(\mathrm{TPEMR}\) derives from a time-warping, \(d\mathrm{PCA}^{w,T_{pe}}\), index computed from T waves at two distant RR bins normalized by the RR range. All the three TPEMR indices were significantly higher for BrS group than for the control group. BrS-S group presented higher TPEMR indexes than BrS-A group for all indices, though significant differences were only shown in the weighted \(\mathrm{TPEMR}_{W2}\) index., Funding was provided by MICIN, Spain, projects: PID2022-140556OB-I00, CNS2023-143599 and TED2021-130459B-I00, and fellowship RYC2021-031413-I, and by Aragon Government group: BSICoS T39 23R., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Temporal variability of ventricular activation in brugada syndrome patients

  • Romagnoli, Sofía
  • Isabel Roquero, Alba
  • Martín-Yebra, Alba
  • Palmieri, Flavio
  • Pueyo Paules, Esther
  • Gomis Román, Pedro
  • Laguna Lasaosa, Pablo
  • Arbelo Lainez, Elena
  • Mincholé, Ana
In Brugada Syndrome (BrS), ventricular fibrillation events peak during night. This temporal pattern suggests that circadianity may modulate arrhythmogenesis. The present work evaluates the circadianity of ventricular activation in BrS patients from 24-hour ECGs with the high-precordial leads. Lead-dependent propagation progression times, \(T_l^p(h)\), are computed every \(h\)-th half hour in each \(l\)-th lead as the time instant along the QRS complex when the QRS energy reaches a percentage, \(p\), of the total QRS energy. \(T_l^p(h)\) is characterized by median and standard deviation over 24 hours, as well as the MESOR and amplitude of the cosinor analysis. The median and MESOR of \(T_l^{70}(h)\) are longer by more than 10 ms in BrS patients than in controls. In particular, the median and standard deviation of \(T_l^p(h)\) at different energy percentages can distinguish between BrS vs controls (\(\mathrm{AUC} \geq 0.8\)), and BrS-I vs BrS-II (\(\mathrm{AUC} = 0.78\)). Cosinor analysis indicates that \(T_l^p(h)\) is less influenced by circadianity than heart rate. The Spearman correlation of \(T_l^p(h)\) with heart rate is lower than 0.5 in each lead for both BrS and controls. These findings suggest that intra-day variability in propagation progression times is not primarily driven by circadianity or heart rate. Furthermore, the temporal variability of \(T_l^p(h)\) is higher in symptomatic BrS patients supporting its potential role as risk stratification marker in BrS., Funding was provided ISCIII Spain (ref: PI24/00691); EU Reference Network ERN GUARD-Heart; MICIN through projects CNS2022-135899, TED2021-130459B- I00, PID2023-148975OB-I00 and PID2022-140556OBI00, through fellowship RYC2019-027420-I; Aragon Government group: BSICoS T39 23R; EU MSCA COFOUND postdoct project ARISTOS, GA:101081334., Peer Reviewed, Postprint (published version)