RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación
Contribución de congreso (ConferenceOutput)
Influence of Gradient and Smoothness of Atrial Wall Thickness on Initiation and Maintenance of Atrial Fibrillation
[EN] This work uses a highly detailed computational model
of human atria to investigate the effect of spatial gradient and smoothing of atrial wall thickness on inducibility
and maintenance of atrial fibrillation (AF) episodes. An
atrial model with homogeneous thickness (HO) was used
as baseline for the generation of different atrial models
including either a low (LG) or high thickness gradient between left/right atrial free wall and the other regions. Since
the model with high spatial gradient presented non-natural
sharp edges between regions, either 1 (HG1) or 2 (HG2)
Laplacian smoothing iterations were applied. Arrhythmic
episodes were initiated using a rapid pacing protocol and
long-living rotors were detected and tracked over time.
Thresholds optimised with receiver operating characteristic analysis were used to define high gradient/curvature regions. Greater spatial gradients increased the atrial model
inducibility and unveiled additional regions vulnerable to
maintain AF drivers. In the models with heterogeneous
wall thickness (LG, HG2 and HG1), 73.5 ± 8.7% of the
long living rotors were found in areas within 1.5 mm from
nodes with high thickness gradient, and 85.0 ± 3.4% in
areas around high endocardial curvature. These findings
promote wall thickness gradient and endocardial curvature as measures of AF vulnerability, Research supported by the European Union's Horizon 2020 research and innovation programme under the Marie Sk¿odowska-Curie grant agreement No.766082 (MY-ATRIA project)