Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 50
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

GPCRmd uncovers the dynamics of the 3D-GPCRome

  • Rodríguez-Espigares, Ismael|||0000-0002-1602-8679
  • Torrens-Fontanals, Mariona|||0000-0001-6233-8945
  • Tiemann, Johanna K. S|||0000-0001-7551-6245
  • Aranda-García, David|||0000-0002-5476-2903
  • Ramírez-Anguita, Juan Manuel|||0000-0002-8509-0927
  • Stepniewski, Tomasz Maciej|||0000-0002-6828-9192
  • Worp, Nathalie
  • Varela-Rial, Alejandro|||0000-0002-6918-1765
  • Morales-Pastor, Adrián
  • Medel-Lacruz, Brian|||0000-0003-2831-7731
  • Pándy-Szekeres, Gáspár|||0000-0002-7697-2696
  • Mayol, Eduardo|||0000-0003-3120-8667
  • Giorgino, Toni|||0000-0001-6449-0596
  • Carlsson, Jens|||0000-0003-4623-2977
  • Deupi, Xavier|||0000-0003-4572-9316
  • Filipek, Slawomir|||0000-0003-3147-3858
  • Filizola, Marta|||0000-0002-4382-8276
  • Gómez-Tamayo, José Carlos|||0000-0003-4709-6030
  • Gonzalez, Angel|||0000-0002-2284-8307
  • Gutiérrez-de-Terán, Hugo|||0000-0003-0459-3491
  • Jiménez-Rosés, Mireia|||0000-0002-4049-8670
  • Jespers, Willem|||0000-0002-4951-9220
  • Kapla, Jon|||0000-0003-3328-1921
  • Khelashvili, George
  • Kolb, Peter|||0000-0003-4089-614X
  • Latek, Dorota|||0000-0002-0429-0637
  • Marti-Solano, Maria|||0000-0003-0373-8927
  • Matricon, Pierre
  • Matsoukas, Minos-Timotheos|||0000-0002-4642-8163
  • Miszta, Przemyslaw
  • Olivella, Mireia|||0000-0002-6035-3399
  • Pérez-Benito, Laura|||0000-0001-9607-9048
  • Provasi, Davide|||0000-0002-2868-303X
  • Ríos, Santiago
  • Rodríguez Torrecillas, Iván
  • Sallander, Jessica
  • Sztyler, Agnieszka|||0009-0008-9459-0078
  • Vasile, Silvana|||0000-0001-5578-7996
  • Weinstein, Harel|||0000-0003-3473-9818
  • Zachariae, Ulrich|||0000-0003-3287-8494
  • Hildebrand, Peter Werner|||0000-0003-0063-1104
  • De Fabritiis, Gianni|||0000-0003-3913-4877
  • Sanz, Ferran|||0000-0002-7534-7661
  • Gloriam, David E.|||0000-0002-4299-7561
  • Cordomí Montoya, Arnau|||0000-0002-3848-2928
  • Guixà González, Ramon|||0000-0003-0397-9800
  • Selent, Jana|||0000-0002-1844-4449
G-protein-coupled receptors (GPCRs) are involved in numerous physiological processes and are the most frequent targets of approved drugs. The explosion in the number of new three-dimensional (3D) molecular structures of GPCRs (3D-GPCRome) over the last decade has greatly advanced the mechanistic understanding and drug design opportunities for this protein family. Molecular dynamics (MD) simulations have become a widely established technique for exploring the conformational landscape of proteins at an atomic level. However, the analysis and visualization of MD simulations require efficient storage resources and specialized software. Here we present GPCRmd (http://gpcrmd.org/), an online platform that incorporates web-based visualization capabilities as well as a comprehensive and user-friendly analysis toolbox that allows scientists from different disciplines to visualize, analyze and share GPCR MD data. GPCRmd originates from a community-driven effort to create an open, interactive and standardized database of GPCR MD simulations.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Validation of the alchemical transfer method for the estimation of relative binding affinities of molecular series

  • Sabanés Zariquiey, Francesc
  • Pérez, Adrià
  • Majewski, Maciej
  • Gallicchio, Emilio
  • De Fabritiis, Gianni
The accurate prediction of protein-ligand binding affinities is crucial for drug discovery. Alchemical free energy calculations have become a popular tool for this purpose. However, the accuracy and reliability of these methods can vary depending on the methodology. In this study, we evaluate the performance of a relative binding free energy protocol based on the alchemical transfer method (ATM), a novel approach based on a coordinate transformation that swaps the positions of two ligands. The results show that ATM matches the performance of more complex free energy perturbation (FEP) methods in terms of Pearson correlation but with marginally higher mean absolute errors. This study shows that the ATM method is competitive compared to more traditional methods in speed and accuracy and offers the advantage of being applicable with any potential energy function., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 823712, and the project PID2020-116564GB-I00 has been funded by MCIN/AEI/10.13039/501100011033, the Torres-Quevedo Programme from the Spanish National Agency for Research (PTQ2020-011145/AEI/10.13039/501100011033). Research reported in this publication was supported by the National Institute of General Medical Sciences (NIGMS) of the National Institutes of Health under award number GM140090. E.G. acknowledges support from the United States’ National Science Foundation (NSF CAREER 1750511).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

NNP/MM: Accelerating molecular dynamics simulations with machine learning potentials and molecular mechanics

  • Galvelis, Raimondas
  • Varela-Rial, Alejandro
  • Doerr, Stefan, 1987-
  • Fino, Roberto
  • Eastman, Peter
  • Markland, Thomas E.
  • Chodera, John D.
  • De Fabritiis, Gianni
Machine learning potentials have emerged as a means to enhance the accuracy of biomolecular simulations. However, their application is constrained by the significant computational cost arising from the vast number of parameters compared with traditional molecular mechanics. To tackle this issue, we introduce an optimized implementation of the hybrid method (NNP/MM), which combines a neural network potential (NNP) and molecular mechanics (MM). This approach models a portion of the system, such as a small molecule, using NNP while employing MM for the remaining system to boost efficiency. By conducting molecular dynamics (MD) simulations on various protein-ligand complexes and metadynamics (MTD) simulations on a ligand, we showcase the capabilities of our implementation of NNP/MM. It has enabled us to increase the simulation speed by ∼5 times and achieve a combined sampling of 1 μs for each complex, marking the longest simulations ever reported for this class of simulations., The authors thank the volunteers of GPUGRID.net for donating computing time. This project has received funding from the Torres-Quevedo Programme from the Spanish National Agency for Research (No. PTQ-17-09078/AEI/10.13039/501100011033) (R.G.); the European Union’s Horizon 2020 research and innovation programme, under Grant Agreement No. 823712 (R.G., A.V.-R., R.F.); the Industrial Doctorates Plan of the Secretariat of Universities and Research of the Department of Economy and Knowledge of the Generalitat of Catalonia (A.V.-R.); the Chan Zuckerberg Initiative DAF (Grant No. 2020-219414), an advised fund of Silicon Valley Community Foundation (S.D., P.E.); and the project PID2020-116564GB-I00 has been funded by MCIN/AEI/10.13039/501100011033. Research reported in this publication was supported by the National Institute of General Medical Sciences (NIGMS) of the National Institutes of Health, under Award No. GM140090 (P.E., T.E.M., J.D.C., G.D.F.). This research was funded in part through the NIH/NCI Cancer Center Support Grant P30 CA008748 (J.D.C.). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Enhancing protein-ligand binding affinity predictions using neural network potentials

  • Sabanés Zariquiey, Francesc
  • Galvelis, Raimondas
  • Gallicchio, Emilio
  • Chodera, John D.
  • Markland, Thomas E.
  • De Fabritiis, Gianni
This letter gives results on improving protein-ligand binding affinity predictions based on molecular dynamics simulations using machine learning potentials with a hybrid neural network potential and molecular mechanics methodology (NNP/MM). We compute relative binding free energies with the Alchemical Transfer Method and validate its performance against established benchmarks and find significant enhancements compared with conventional MM force fields like GAFF2., The authors thank the volunteers of GPUGRID.net for donating computing time. This project has received funding from the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 823712, and the project PID2020-116564GB-I00 has been funded by MCIN/AEI/10.13039/501100011033; the Torres-Quevedo Programme from the Spanish National Agency for Research (PTQ2020-011145/AEI/10.13039/501100011033). Research reported in this publication was supported by the National Institute of General Medical Sciences (NIGMS) of the National Institutes of Health under Award Number R01GM140090 to T.E.M., G.D.F., and J.D.C. E.G. acknowledges support from the United States National Science Foundation (NSF CAREER 1750511). J.D.C. also acknowledges support from NIH Grant P30CA008748 and the Sloan Kettering Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Equivariant graph neural networks for toxicity prediction

  • Cremer, Julian
  • Medrano Sandonas, Leonardo
  • Tkatchenko, Alexandre
  • Clevert, Djork-Arné
  • De Fabritiis, Gianni
Predictive modeling of toxicity is a crucial step in the drug discovery pipeline. It can help filter out molecules with a high probability of failing in the early stages of de novo drug design. Thus, several machine learning (ML) models have been developed to predict the toxicity of molecules by combining classical ML techniques or deep neural networks with well-known molecular representations such as fingerprints or 2D graphs. But the more natural, accurate representation of molecules is expected to be defined in physical 3D space like in ab initio methods. Recent studies successfully used equivariant graph neural networks (EGNNs) for representation learning based on 3D structures to predict quantum-mechanical properties of molecules. Inspired by this, we investigated the performance of EGNNs to construct reliable ML models for toxicity prediction. We used the equivariant transformer (ET) model in TorchMD-NET for this. Eleven toxicity data sets taken from MoleculeNet, TDCommons, and ToxBenchmark have been considered to evaluate the capability of ET for toxicity prediction. Our results show that ET adequately learns 3D representations of molecules that can successfully correlate with toxicity activity, achieving good accuracies on most data sets comparable to state-of-the-art models. We also test a physicochemical property, namely, the total energy of a molecule, to inform the toxicity prediction with a physical prior. However, our work suggests that these two properties can not be related. We also provide an attention weight analysis for helping to understand the toxicity prediction in 3D space and thus increase the explainability of the ML model. In summary, our findings offer promising insights considering 3D geometry information via EGNNs and provide a straightforward way to integrate molecular conformers into ML-based pipelines for predicting and investigating toxicity prediction in physical space. We expect that in the future, especially for larger, more diverse data sets, EGNNs will be an essential tool in this domain., This research used computational resources provided by the High-Performance Center (HPC) at the University of Luxembourg. J.C. received funding from the European Union’s Horizon 2020 research and innovation program under the Marie Skłodowska-Curie Actions grant agreement “Advanced machine learning for Innovative Drug Discovery (AIDD)” No. 956832. L.M.S. thanks S. Goger for fruitful discussions about the influence of functional groups in toxicity prediction. G.D.F. acknowledges funding from the European Union’s Horizon 2020 research and innovation program under Grant Agreement No. 823712; and the project PID2020-116564GB-I00 has been funded by MCIN/AEI/10.13039/501100011033.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

PlayMolecule glimpse: understanding protein-ligand property predictions with interpretable neural networks

  • Varela-Rial, Alejandro
  • Maryanow, Iain
  • Majewski, Maciej
  • Doerr, Stefan, 1987-
  • Schapin, Nikolai
  • Jiménez Luna, José, 1993-
  • De Fabritiis, Gianni
Deep learning has been successfully applied to structure-based protein-ligand affinity prediction, yet the black box nature of these models raises some questions. In a previous study, we presented KDEEP, a convolutional neural network that predicted the binding affinity of a given protein-ligand complex while reaching state-of-the-art performance. However, it was unclear what this model was learning. In this work, we present a new application to visualize the contribution of each input atom to the prediction made by the convolutional neural network, aiding in the interpretability of such predictions. The results suggest that KDEEP is able to learn meaningful chemistry signals from the data, but it has also exposed the inaccuracies of the current model, serving as a guideline for further optimization of our prediction tools., The authors thank Acellera Ltd. for funding. G.D.F. acknowledges support from PID2020-116564GB-I00/MICIN/AEI/10.13039/501100011033 Ministerio de Ciencia e Innovación. This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 823712 (CompBioMed2) and from the Industrial Doctorates Plan of the Secretariat of Universities and Research of the Department of Economy and Knowledge of the Generalitat of Catalonia.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

TorchMD: a deep learning framework for molecular simulations

  • Doerr, Stefan, 1987-
  • Majewski, Maciej
  • Pérez, Adrià
  • Krämer, Andreas
  • Clementi, Cecilia
  • Noé, Frank
  • Giorgino, Toni
  • De Fabritiis, Gianni
Molecular dynamics simulations provide a mechanistic description of molecules by relying on empirical potentials. The quality and transferability of such potentials can be improved leveraging data-driven models derived with machine learning approaches. Here, we present TorchMD, a framework for molecular simulations with mixed classical and machine learning potentials. All force computations including bond, angle, dihedral, Lennard-Jones, and Coulomb interactions are expressed as PyTorch arrays and operations. Moreover, TorchMD enables learning and simulating neural network potentials. We validate it using standard Amber all-atom simulations, learning an ab initio potential, performing an end-to-end training, and finally learning and simulating a coarse-grained model for protein folding. We believe that TorchMD provides a useful tool set to support molecular simulations of machine learning potentials. Code and data are freely available at github.com/torchmd., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 823712 (CompBioMed2 Project).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Machine learning coarse-grained potentials of protein thermodynamics

  • Majewski, Maciej
  • Pérez, Adrià
  • Thölke, Philipp
  • Doerr, Stefan, 1987-
  • Charron, Nicholas E.
  • Giorgino, Toni
  • Husic, Brooke E.
  • Clementi, Cecilia
  • Noé, Frank
  • De Fabritiis, Gianni
A generalized understanding of protein dynamics is an unsolved scientific problem, the solution of which is critical to the interpretation of the structure-function relationships that govern essential biological processes. Here, we approach this problem by constructing coarse-grained molecular potentials based on artificial neural networks and grounded in statistical mechanics. For training, we build a unique dataset of unbiased all-atom molecular dynamics simulations of approximately 9 ms for twelve different proteins with multiple secondary structure arrangements. The coarse-grained models are capable of accelerating the dynamics by more than three orders of magnitude while preserving the thermodynamics of the systems. Coarse-grained simulations identify relevant structural states in the ensemble with comparable energetics to the all-atom systems. Furthermore, we show that a single coarse-grained potential can integrate all twelve proteins and can capture experimental structural features of mutated proteins. These results indicate that machine learning coarse-grained potentials could provide a feasible approach to simulate and understand protein dynamics., The project PID2020-116564GB-I00 has been funded by MCIN/AEI/10.13039/501100011033 (G.D.F.) This project has received funding from the Torres-Quevedo Program from the Spanish National Agency for Research (PTQ2020-011145/AEI/10.13039/501100011033) (M.M.); the Torres-Quevedo Program from the Spanish National Agency for Research (PTQ2021-011669/AEI/10.13039/501100011033) (A.P.); the European Union’s Horizon 2020 research and innovation program under grant agreement No. 823712 (G.D.F.); NLM Training Program in Biomedical Informatics and Data Science (grant no. 5T15LM007093-27) (N.E.C.); Deutsche Forschungsgemeinschaft (DFG, GRK DAEDALUS, RTG 2433, Project Q05) (N.E.C.); National Science Foundation (CHE-1900374 and PHY-2019745) (C.C.); Einstein Foundation Berlin (Project 0420815101) (C.C.); Deutsche Forschungsgemeinschaft (DFG) SFB 1114 projects A04, B03, and B08, SFB/TRR 186 project A12, and SFB 1078 project C7 (C.C.); Deutsche Forschungsgemeinschaft (DFG) projects CRC1114/A04, CRC1114/C03 (F.N.); European Research Council (ERC) project ERG CoG 772230 (F.N.); Berlin Mathematics Center MATH+ project AA1-6 (F.N.); the National Institute of General Medical Sciences (NIGMS) of the National Institutes of Health under award number GM140090 (G.D.F.). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. The authors thank the volunteers of GPUGRID.net for donating computing time. T.G. acknowledges the CINECA award under the ISCRA initiative, for the availability of high performance computing resources and support. This project has received funding from the Spoke 7 of the National Centre for HPC, Big Data and Quantum Computing (CN00000013) of the NextGenerationEU initiative (T.G.).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Characterization of partially ordered states in the intrinsically disordered N-terminal domain of p53 using millisecond molecular dynamics simulations

  • Herrera Nieto, Pablo, 1992-
  • Pérez, Adrià
  • De Fabritiis, Gianni
The exploration of intrinsically disordered proteins in isolation is a crucial step to understand their complex dynamical behavior. In particular, the emergence of partially ordered states has not been explored in depth. The experimental characterization of such partially ordered states remains elusive due to their transient nature. Molecular dynamics mitigates this limitation thanks to its capability to explore biologically relevant timescales while retaining atomistic resolution. Here, millisecond unbiased molecular dynamics simulations were performed in the exemplar N-terminal region of p53. In combination with state-of-the-art Markov state models, simulations revealed the existence of several partially ordered states accounting for [Formula: see text] 40% of the equilibrium population. Some of the most relevant states feature helical conformations similar to the bound structure of p53 to Mdm2, as well as novel [Formula: see text]-sheet elements. This highlights the potential complexity underlying the energy surface of intrinsically disordered proteins., The authors thank volunteers at GPUGRID.net for contributing with computational resources and Acellera for funding. G.D.F. acknowledges support from MINECO (Unidad de Excelencia María de Maeztu MDM-2014-0370 and BIO2017-82628-P) and FEDER. This project received funding from the European Union’s Horizon 2020 Research and Innovation Programme under Grant Agreement 823712 (CompBioMed2 Project).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Ventricular anatomical complexity and sex differences impact predictions from electrophysiological computational models

  • Gonzalez Martin, Pablo
  • Sacco, Federica
  • Butakoff, Constantine
  • Doste Beltrán, Rubén
  • Bederian, Carlos
  • Gutierrez Espinosa de los Monteros, Lilian K.
  • Houzeaux, Guillaume
  • Iaizzo, Paul A.
  • Iles, Tinen L.
  • Vázquez, Mariano
  • Aguado-Sierra, Jazmin
Includes supplementary materials for the online appendix., The aim of this work was to analyze the influence of sex hormones and anatomical details (trabeculations and false tendons) on the electrophysiology of healthy human hearts. Additionally, sex- and anatomy-dependent effects of ventricular tachycardia (VT) inducibility are presented. To this end, four anatomically normal, human, biventricular geometries (two male, two female), with identifiable trabeculations, were obtained from high-resolution, ex-vivo MRI and represented by detailed and smoothed geometrical models (with and without the trabeculations). Additionally one model was augmented by a scar. The electrophysiology finite element model (FEM) simulations were carried out, using O’Hara-Rudy human myocyte model with sex phenotypes of Yang and Clancy. A systematic comparison between detailed vs smooth anatomies, male vs female normal hearts was carried out. The heart with a myocardial infarction was subjected to a programmed stimulus protocol to identify the effects of sex and anatomical detail on ventricular tachycardia inducibility. All female hearts presented QT-interval prolongation however the prolongation interval in comparison to the male phenotypes was anatomy-dependent and was not correlated to the size of the heart. Detailed geometries showed QRS fractionation and increased T-wave magnitude in comparison to the corresponding smoothed geometries. A variety of sustained VTs were obtained in the detailed and smoothed male geometries at different pacing locations, which provide evidence of the geometry-dependent differences regarding the prediction of the locations of reentry channels. In the female phenotype, sustained VTs were induced in both detailed and smooth geometries with RV apex pacing, however no consistent reentry channels were identified. Anatomical and physiological cardiac features play an important role defining risk in cardiac disease. These are often excluded from cardiac electrophysiology simulations. The assumption that the cardiac endocardium is smooth may produce inaccurate predictions towards the location of reentry channels in in-silico tachycardia inducibility studies., JA-S, FS, GH and MV are supported by the European Union’s Horizon 2020 research and innovation programme under grant agreements No 675451 (Compbiomed project phase 1) and No 823712 (CompBioMed project, phase 2) and project No 777204 (SilicoFCM project). Part of the simulation computing hours were provided by the CompBioMed project phase 1. JA-S was awarded computation time from Red Espanola de Supercomputacion (RES). (Activity IDs: FI-2018-2-0049 and BCV-2019-2-0014) JA-S is funded by a Ramon y Cajal fellowship (RYC-2017-22532), Ministerio de Ciencia e Innovacion, Spain; and by Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion 2017-2020 from the Ministerio de Ciencia e Innovacion y Universidades (PID2019-104356RBC41/AEI/10.13039/501100011033): meHeart ME PID2019-104356RB-C44. CB is funded by the Torres Quevedo Program (PTQ2018-010290), Ministerio de Ciencia e Innovacion, Spain. MV, GH and CB are funded by the Spanish Neotec project EXP - 00123159/SNEO-20191113 Generador de corazones virtuales. LKGM was funded by Fundacion Carolina-BBVA. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. There was no additional external funding received for this study.
Repisalud
Publicación Artículo científico (JournalArticle)

Ventricular anatomical complexity and sex differences impact predictions from electrophysiological computational models.

  • Gonzalez-Martin, Pablo
  • Sacco, Federica
  • Butakoff, Constantine
  • Doste, Ruben
  • Bederian, Carlos
  • Gutierrez Espinosa de Los Monteros, Lilian K
  • Houzeaux, Guillaume
  • Iaizzo, Paul A
  • Iles, Tinen L
  • Vazquez, Mariano
  • Aguado-Sierra, Jazmin
The aim of this work was to analyze the influence of sex hormones and anatomical details (trabeculations and false tendons) on the electrophysiology of healthy human hearts. Additionally, sex- and anatomy-dependent effects of ventricular tachycardia (VT) inducibility are presented. To this end, four anatomically normal, human, biventricular geometries (two male, two female), with identifiable trabeculations, were obtained from high-resolution, ex-vivo MRI and represented by detailed and smoothed geometrical models (with and without the trabeculations). Additionally one model was augmented by a scar. The electrophysiology finite element model (FEM) simulations were carried out, using O'Hara-Rudy human myocyte model with sex phenotypes of Yang and Clancy. A systematic comparison between detailed vs smooth anatomies, male vs female normal hearts was carried out. The heart with a myocardial infarction was subjected to a programmed stimulus protocol to identify the effects of sex and anatomical detail on ventricular tachycardia inducibility. All female hearts presented QT-interval prolongation however the prolongation interval in comparison to the male phenotypes was anatomy-dependent and was not correlated to the size of the heart. Detailed geometries showed QRS fractionation and increased T-wave magnitude in comparison to the corresponding smoothed geometries. A variety of sustained VTs were obtained in the detailed and smoothed male geometries at different pacing locations, which provide evidence of the geometry-dependent differences regarding the prediction of the locations of reentry channels. In the female phenotype, sustained VTs were induced in both detailed and smooth geometries with RV apex pacing, however no consistent reentry channels were identified. Anatomical and physiological cardiac features play an important role defining risk in cardiac disease. These are often excluded from cardiac electrophysiology simulations. The assumption that the cardiac endocardium is smooth may produce inaccurate predictions towards the location of reentry channels in in-silico tachycardia inducibility studies.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Cardiac computational modelling, Modelización computacional cardiaca

  • Bragard, Jean R.
  • Cámara, Óscar
  • Echebarria, Blas
  • Giorda, Luca Gerardo
  • Pueyo, Esther
  • Sebastián, Rafael
  • Soudah, Eduardo
  • Vázquez, Mariano
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Cardiovascular diseases currently have a major social and economic impact, constituting one of the leading causes of mortality and morbidity. Personalized computational models of the heart are demonstrating their usefulness both to help understand the mechanisms underlying cardiac disease, and to optimize their treatment and predict the patient's response. Within this framework, the Spanish Research Network for Cardiac Computational Modelling (VHeart-SN) has been launched. The general objective of the VHeart-SN network is the development of an integrated, modular and multiscale multiphysical computational model of the heart. This general objective is addressed through the following specific objectives: a) to integrate the different numerical methods and models taking into account the specificity of patients; b) to assist in advancing knowledge of the mechanisms associated with cardiac and vascular diseases; and c) to support the application of different personalized therapies. This article presents the current state of cardiac computational modelling and different scientific works conducted by the members of the network to gain greater understanding of the characteristics and usefulness of these models., [ES] Las enfermedades cardiovasculares tienen en la actualidad un gran impacto social y económico y constituyen una de las principales causas de mortalidad y morbilidad. Los modelos computacionales personalizados del corazón están demostrando ser útiles tanto para ayudar a comprender los mecanismos subyacentes a las patologías cardiacas como para optimizar su tratamiento prediciendo la respuesta del paciente. En este contexto, se ha puesto en marcha la Red Española de Investigación en Modelización Computacional Cardiaca (V-Heart SN). El objetivo general de V-Heart SN es el desarrollo de un modelo computacional multifísico y multiescala integrado del corazón. Este objetivo general se aborda a través de los siguientes objetivos específicos: a) integrar los diferentes modelos numéricos teniendo en cuenta la especificidad de los pacientes; b) ayudar a avanzar en el conocimiento de los mecanismos asociados a las diferentes patologías cardiacas y vasculares; y c) apoyar la aplicación de terapias personalizadas. Este artículo presenta el estado actual de la modelización computacional cardiaca y los diferentes trabajos científicos desarrollados por los miembros de la red para favorecer una mayor comprensión de las características y utilidad de los modelos., This work was partially supported by: Acciones de Dinamización Redes de Excelencia 2016, Plan Estatal de Investigación Científica y Técnica y de Innovación, Ministerio de Economía y Competitividad (DPI2016-81873-REDT) and CompBioMed2, Grant agreement ID: 823712. The authors also thank the support of the European Research Council (ERC-StG 638284) and the Spanish Goverment through the following programmes: Retos I+D (TIN2014-59932-JIN, RTI2018-093416-B-I00, SAF2017-88019-C3-3R, RTI2018- 101193-B-I00, DPI2016-75799-R and PID2019-105674RB-I00); María de Maeztu (MDM-2015-0502); and Severo Ochoa (SEV2017-0718 and CEX2018-000797-S)
DAU Arxiu Digital de la Universitat Ramon Llull
Publicación Artículo científico (JournalArticle)

Fluid-structure interaction simulations outperform computational fluid dynamics in the description of thoracic aorta haemodynamics and in the differentiation of progressive dilation in Marfan syndrome patients

  • Martorell López, Jordi
  • Molins, Jose Javier
  • Pons, R.
  • Guala, A.
  • Rodríguez-Palomares, J.F.
  • Cajas, J.C.
  • Dux-Santoy, L.
  • Teixidó-Tura, G.
  • Vázquez, M.
  • Evangelista, A.
Abnormal fluid dynamics at the ascending aorta may be at the origin of aortic aneurysms. This study was aimed at comparing the performance of computational fluid dynamics (CFD) and fluid–structure interaction (FSI) simulations against four-dimensional (4D) flow magnetic resonance imaging (MRI) data; and to assess the capacity of advanced fluid dynamics markers to stratify aneurysm progression risk. Eight Marfan syndrome (MFS) patients, four with stable and four with dilating aneurysms of the proximal aorta, and four healthy controls were studied. FSI and CFD simulations were performed with MRI-derived geometry, inlet velocity field and Young's modulus. Flow displacement, jet angle and maximum velocity evaluated from FSI and CFD simulations were compared to 4D flow MRI data. A dimensionless parameter, the shear stress ratio (SSR), was evaluated from FSI and CFD simulations and assessed as potential correlate of aneurysm progression. FSI simulations successfully matched MRI data regarding descending to ascending aorta flow rates (R2 = 0.92) and pulse wave velocity (R2 = 0.99). Compared to CFD, FSI simulations showed significantly lower percentage errors in ascending and descending aorta in flow displacement (−46% ascending, −41% descending), jet angle (−28% ascending, −50% descending) and maximum velocity (−37% ascending, −34% descending) with respect to 4D flow MRI. FSI- but not CFD-derived SSR differentiated between stable and dilating MFS patients. Fluid dynamic simulations of the thoracic aorta require fluid–solid interaction to properly reproduce complex haemodynamics. FSI- but not CFD-derived SSR could help stratifying MFS patients.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Ventricular anatomical complexity and sex differences impact predictions from electrophysiological computational models

  • Gonzalez Martin, Pablo
  • Sacco, Federica|||0000-0001-6561-8862
  • Butakoff, Constantine
  • Doste, Ruben
  • Bederian, Carlos
  • Houzeaux, Guillaume|||0000-0002-2592-1426
  • Vázquez, Mariano|||0000-0002-2526-6708
  • Aguado Sierra, Jazmín|||0000-0002-9711-3225
The aim of this work was to analyze the influence of sex hormones and anatomical details (trabeculations and false tendons) on the electrophysiology of healthy human hearts. Additionally, sex- and anatomy-dependent effects of ventricular tachycardia (VT) inducibility are presented. To this end, four anatomically normal, human, biventricular geometries (two male, two female), with identifiable trabeculations, were obtained from high-resolution, ex-vivo MRI and represented by detailed and smoothed geometrical models (with and without the trabeculations). Additionally one model was augmented by a scar. The electrophysiology finite element model (FEM) simulations were carried out, using O’Hara-Rudy human myocyte model with sex phenotypes of Yang and Clancy. A systematic comparison between detailed vs smooth anatomies, male vs female normal hearts was carried out. The heart with a myocardial infarction was subjected to a programmed stimulus protocol to identify the effects of sex and anatomical detail on ventricular tachycardia inducibility. All female hearts presented QT-interval prolongation however the prolongation interval in comparison to the male phenotypes was anatomy-dependent and was not correlated to the size of the heart. Detailed geometries showed QRS fractionation and increased T-wave magnitude in comparison to the corresponding smoothed geometries. A variety of sustained VTs were obtained in the detailed and smoothed male geometries at different pacing locations, which provide evidence of the geometry-dependent differences regarding the prediction of the locations of reentry channels. In the female phenotype, sustained VTs were induced in both detailed and smooth geometries with RV apex pacing, however no consistent reentry channels were identified. Anatomical and physiological cardiac features play an important role defining risk in cardiac disease. These are often excluded from cardiac electrophysiology simulations. The assumption that the cardiac endocardium is smooth may produce inaccurate predictions towards the location of reentry channels in in-silico tachycardia inducibility studies, JA-S, FS, GH and MV are supported by the European Union’s Horizon 2020 research and innovation programme under grant agreements No 675451 (Compbiomed project phase 1) and No 823712 (CompBioMed project, phase 2) and project No 777204 (SilicoFCM project). Part of the simulation computing hours were provided by the CompBioMed project phase 1. JA-S was awarded computation time from Red Espanola de Supercomputacion (RES). (Activity IDs: FI-2018-2-0049 and BCV-2019-2-0014) JA-S is funded by a Ramon y Cajal fellowship (RYC-2017-22532), Ministerio de Ciencia e Innovacion, Spain; and by Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion 2017-2020 from the Ministerio de Ciencia e Innovacion y Universidades (PID2019-104356RBC41/AEI/10.13039/501100011033): meHeart ME PID2019-104356RB-C44. CB is funded by the Torres Quevedo Program (PTQ2018-010290), Ministerio de Ciencia e Innovacion, Spain. MV, GH and CB are funded by the Spanish Neotec project EXP - 00123159/SNEO-20191113 Generador de corazones virtuales. LKGM was funded by Fundacion Carolina-BBVA. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. There was no additional external funding received for this study., Peer Reviewed, "Article signat per 11 autors/es: Pablo Gonzalez-Martin,Federica Sacco,Constantine Butakoff,Ruben Doste,Carlos Bederian,Lilian K. Gutierrez Espinosa de los Monteros,Guillaume Houzeaux,Paul A. Iaizzo,Tinen L. Iles,Mariano Vazquez,Jazmin Aguado-Sierra"
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Fluid–structure interaction simulations outperform computational fluid dynamics in the description of thoracic aorta haemodynamics and in the differentiation of progressive dilation in Marfan syndrome patients

  • Pons, Ramón
  • Cajas, Juan Carlos
  • Rodríguez-Palomares, José F.
  • Guala, Andrea
  • Dux-Santoy, Lydia
  • Teixidó-Tura, Gisela
  • Molins, José Javier
  • Vázquez, Mariano|||0000-0002-2526-6708
  • Evangelista, Arturo
  • Martorell, Jordi
Abnormal fluid dynamics at the ascending aorta may be at the origin of aortic aneurysms. This study was aimed at comparing the performance of computational fluid dynamics (CFD) and fluid–structure interaction (FSI) simulations against four-dimensional (4D) flow magnetic resonance imaging (MRI) data; and to assess the capacity of advanced fluid dynamics markers to stratify aneurysm progression risk. Eight Marfan syndrome (MFS) patients, four with stable and four with dilating aneurysms of the proximal aorta, and four healthy controls were studied. FSI and CFD simulations were performed with MRI-derived geometry, inlet velocity field and Young's modulus. Flow displacement, jet angle and maximum velocity evaluated from FSI and CFD simulations were compared to 4D flow MRI data. A dimensionless parameter, the shear stress ratio (SSR), was evaluated from FSI and CFD simulations and assessed as potential correlate of aneurysm progression. FSI simulations successfully matched MRI data regarding descending to ascending aorta flow rates (R2 = 0.92) and pulse wave velocity (R2 = 0.99). Compared to CFD, FSI simulations showed significantly lower percentage errors in ascending and descending aorta in flow displacement (−46% ascending, −41% descending), jet angle (−28% ascending, −50% descending) and maximum velocity (−37% ascending, −34% descending) with respect to 4D flow MRI. FSI- but not CFD-derived SSR differentiated between stable and dilating MFS patients. Fluid dynamic simulations of the thoracic aorta require fluid–solid interaction to properly reproduce complex haemodynamics. FSI- but not CFD-derived SSR could help stratifying MFS patients., This study was funded by Ministerio de Economía y Competitividad (grant no. RTC-2016-5152-1), Fundació la Marató de TV3 (grant no. 20151330), FP7 People: Marie-Curie Actions (grant no. 267128), Instituto de Salud Carlos III (grant nos PI14/0106 and PI17/00381) and ‘la Caixa’ Foundation. M.V. was funded by CompBioMed2, grant agreement ID: 823712, funded under: H2020-EU.1.4.1.3; and SILICOFCM, grant agreement ID: 777204, funded under: H2020-EU.3.1.5., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Performance Assessment of an Electrostatic Filter-Diverter Stent Cerebrovascular Protection Device: Evaluation of a Range of Potential Electrostatic Fields Focusing on Small Particles

  • Eguzkitza, Beatriz|||0000-0002-3302-6667
  • Navia, José A
  • Houzeaux, Guillaume|||0000-0002-2592-1426
  • Butakoff, Constantine
  • Vázquez, Mariano|||0000-0002-2526-6708
Silent Brain Infarction (SBI) is increasingly recognized in patients with cardiac conditions, particularly Atrial Fibrillation (AF) in elderly patients and those undergoing Transcatheter Aortic Valve Implantation (TAVI). While these infarcts often go unnoticed due to a lack of acute symptoms, they are associated with a threefold increase in stroke risk and are considered a precursor to ischemic stroke. Moreover, accumulating evidence suggests that SBI may contribute to the development of dementia, depression, and cognitive decline, particularly in the elderly population. The burden of SBI is substantial, with studies showing that up to 11 million Americans may experience a silent stroke annually. In AF patients, silent brain infarcts are common and can lead to progressive brain damage, even in those receiving anticoagulation therapy. The use of cerebral embolic protection devices (CEPDs) during TAVI has been explored to mitigate the risk of stroke; however, their efficacy remains under debate. Despite advancements in TAVI technology, cerebrovascular events, including silent brain lesions, continue to pose significant challenges, underscoring the need for improved preventive strategies and therapeutic approaches. We propose a device consisting of a strut structure placed at the base of the treated artery to model the potential risk of cerebral embolisms caused by atrial fibrillation, thromboembolism, or dislodged debris of varying potential TAVI patients. The study has been carried out in two stages. Both are based on computational fluid dynamics (CFD) coupled with the Lagrangian particle tracking method. The first stage of the work evaluates a variety of strut thicknesses and inter-strut spacings, contrasting with the device-free baseline geometry. The analysis is carried out by imposing flow rate waveforms characteristic of healthy and AF patients. Boundary conditions are calibrated to reproduce physiological flow rates and pressures in a patient’s aortic arch. In the second stage, the optimal geometric design from the first stage was employed, with the addition of lateral struts to prevent the filtration of particles and electronegatively charged strut surfaces, studying the effect of electrical forces on the clots if they are considered charged. Flowrate boundary conditions were used to emulate both healthy and AF conditions. Results from numerical simulations coming from the first stage indicate that the device blocks particles of sizes larger than the inter-strut spacing. It was found that lateral strut space had the highest impact on efficacy. Based on the results of the second stage, deploying the electronegatively charged device in all three aortic arch arteries, the number of particles entering these arteries was reduced on average by 62.6 % and 51.2 %, for the healthy and diseased models respectively, matching or surpassing current oral anticoagulant efficacy. In conclusion, the device demonstrated a two-fold mechanism for filtering emboli: (1) while the smallest particles are deflected by electrostatic repulsion, avoiding micro embolisms, which could lead to cognitive impairment, the largest ones are mechanically filtered since they cannot fit in between the struts, effectively blocking the full range of particle sizes analyzed in this study. The device presented in this manuscript offers an anticoagulant-free method to prevent stroke and SBIs, imperative given the growing population of AF and elderly patients., This work was partially financed by the European Project “An ecosystem for digital twins in healthcare (EDITH)” under the call: DIGITAL-2021-DEPLOY-01-TWINS-HEALTH, Ref: 101083771. The research has been also supported by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No. 713673, by the project CompBioMed2 (H2020-EU.1.4.1.3. Grant No. 823712), by CREXDATA project (HORIZON-CL4-2022-DATA-01. Grant No. 101092749), and by the EIC Accelerator grant “ELVIS—ELEM Virtual Heart Populations for Supercomputers” Grant ID 190134524., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Concomitant respiratory failure can impair myocardial oxygenation in patients with acute cardiogenic shock supported by VA-ECMO

  • Prisco, Anthony R.
  • Aguado Sierra, Jazmín|||0000-0002-9711-3225
  • Butakoff, Constantine
  • Vázquez, Mariano|||0000-0002-2526-6708
  • Houzeaux, Guillaume|||0000-0002-2592-1426
  • Eguzkitza, Beatriz|||0000-0002-3302-6667
  • Bartos, Jason A.
  • Yannopoulos, Demetris
  • Raveendran, Ganesh
  • Holm, Mikayle
  • Iles, Tinen
  • Mahr, Claudius
  • Iaizzo, Paul A.
Venous-arterial extracorporeal membrane oxygenation (VA-ECMO) treatment for acute cardiogenic shock in patients who also have acute lung injury predisposes development of a serious complication called “north-south syndrome” (NSS) which causes cerebral hypoxia. NSS is poorly characterized and hemodynamic studies have focused on cerebral perfusion ignoring the heart. We hypothesized in NSS the heart would be more likely to receive hypoxemic blood than the brain due to the proximity of the coronary arteries to the aortic annulus. To test this, we conducted a computational fluid dynamics simulation of blood flow in a human supported by VA-ECMO. Simulations quantified the fraction of blood at each aortic branching vessel originating from residual native cardiac output versus VA-ECMO. As residual cardiac function was increased, simulations demonstrated myocardial hypoxia would develop prior to cerebral hypoxia. These results illustrate the conditions where NSS will develop and the relative cardiac function that will lead to organ-specific hypoxia., This work was supported in part by the University of Minnesota’s Medical School Academic Investment Education Program grant and the Institute for Engineering in Medicine. We also acknowledge the Partnership for Advanced Computing in Europe (PRACE) for awarding us access to Joliot-Curie Rome supercomputer at Bruyères-le-Châtel, under the project Cardiovascular-COVID. Additionally, we would like to acknowledge the Torres Quevedo Program, the Ramón y Cajal Program, and the European Institute of Innovation and Technology for support., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Performance assessment of an electrostatic filter-diverter stent cerebrovascular protection device. Is it possible not to use anticoagulants in atrial fibrilation elderly patients?

  • Eguzkitza, Beatriz|||0000-0002-3302-6667
  • Oks, David|||0000-0002-9659-0484
  • Navia, José A.
  • Houzeaux, Guillaume|||0000-0002-2592-1426
  • Butakoff, Constantine
  • Fisa, María
  • Campoy Millán, Ariadna
  • Vázquez, Mariano|||0000-0002-2526-6708
Stroke is the second leading cause of death worldwide. Nearly two-thirds of strokes are produced by cardioembolisms, and half of cardioembolic strokes are triggered by Atrial Fibrillation (AF), the most common type of arrhythmia. A more recent cause of cardioembolisms is Transcatheter Aortic Valve Replacements (TAVRs), which may onset post-procedural adverse events such as stroke and Silent Brain Infarcts (SBIs), for which no definitive treatment exists, and which will only get worse as TAVRs are implanted in younger and lower risk patients. It is well known that some specific characteristics of elderly patients may lower the safety and efficacy of anticoagulation therapy, making it a real urgency to find alternative therapies. We propose a device consisting of a strut structure placed at the base of the treated artery to model the potential risk of cerebral embolisms caused by dislodged debris of varying sizes. This work analyzes a design based on a patented medical device, intended to block cardioembolisms from entering the cerebrovascular system, with a particular focus on AF, and potentially TAVR patients. The study has been carried out in two stages. Both of them based on computational fluid dynamics (CFD) coupled with Lagrangian particle tracking method. The first stage of the work evaluates a variety of strut thicknesses and inter-strut spacings, contrasting with the device-free baseline geometry. The analysis is carried out by imposing flowrate waveforms characteristic of both healthy and AF patients. Boundary conditions are calibrated to reproduce physiological flowrates and pressures in a patient's aortic arch. In the second stage, the optimal geometric design from the first stage was employed, with the addition of lateral struts to prevent the filtration of particles and electronegatively charged strut surfaces, studying the effect of electrical forces on the clots if they are considered charged. Flowrate boundary conditions were used to emulate both healthy and AF conditions. Results from numerical simulations coming form the first stage indicate that the device blocks particles of sizes larger than the inter-strut spacing. It was found that lateral strut space had the highest impact on efficacy. Based on the results of the second stage, deploying the electronegatively charged device in all three aortic arch arteries, the number of particles entering these arteries was reduced on average by 62.6% and 51.2%, for the healthy and diseased models respectively, matching or surpassing current oral anticoagulant efficacy. In conclusion, the device demonstrated a two-fold mechanism for filtering emboli: while the smallest particles are deflected by electrostatic repulsion, avoiding microembolisms, which could lead to cognitive impairment, the largest ones are mechanically filtered since they cannot fit in between the struts, effectively blocking the full range of particle sizes analyzed in this study. The device presented in this manuscript offers an anticoagulant-free method to prevent stroke and SBIs, imperative given the growing population of AF and elderly patients., This research has been supported by “ELEM biotech - the virtual human factory” (www.elem.bio), an INPhINIT fellowship from “la Caixa” Foundation (fellowship ID: LCF/BQ/DI18/11660044), by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No. 713673., by the project CompBioMed2 (H2020-EU.1.4.1.3. Grant No. 823712), by CREXDATA project (HORIZON-CL4-2022-DATA-01. Grant No. 101092749) and by Torres Quevedo Program (PTQ2018-010290), Ministerio de Ciencia e Innovacion, Spain. ELEM Biotech was not involved in the study design, analysis, interpretation of data, the writing of this article or the decision to submit it for publication., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Human biventricular electromechanical simulations on the progression of electrocardiographic and mechanical abnormalities in post-myocardial infarction

  • Wang, Zhinuo J
  • Santiago, Alfonso|||0000-0002-9374-1275
  • Zhou, Xin
  • Wang, Lei
  • Margara, Francesca
  • Levrero-Florencio, Francesc
  • Das, Arka
  • Kelly, Chris
  • Dall'Armellina, Erica
  • Vázquez, Mariano|||0000-0002-2526-6708
  • Rodriguez, Blanca
Aims Develop, calibrate and evaluate with clinical data a human electromechanical modelling and simulation framework for multiscale, mechanistic investigations in healthy and post-myocardial infarction (MI) conditions, from ionic to clinical biomarkers. Methods and results Human healthy and post-MI electromechanical simulations were conducted with a novel biventricular model, calibrated and evaluated with experimental and clinical data, including torso/biventricular anatomy from clinical magnetic resonance, state-of-the-art human-based membrane kinetics, excitation–contraction and active tension models, and orthotropic electromechanical coupling. Electromechanical remodelling of the infarct/ischaemic region and the border zone were simulated for ischaemic, acute, and chronic states in a fully transmural anterior infarct and a subendocardial anterior infarct. The results were compared with clinical electrocardiogram and left ventricular ejection fraction (LVEF) data at similar states. Healthy model simulations show LVEF 63%, with 11% peak systolic wall thickening, QRS duration and QT interval of 100 ms and 330 ms. LVEF in ischaemic, acute, and chronic post-MI states were 56%, 51%, and 52%, respectively. In linking the three post-MI simulations, it was apparent that elevated resting potential due to hyperkalaemia in the infarcted region led to ST-segment elevation, while a large repolarization gradient corresponded to T-wave inversion. Mechanically, the chronic stiffening of the infarct region had the benefit of improving systolic function by reducing infarct bulging at the expense of reducing diastolic function by inhibiting inflation. Conclusion Our human-based multiscale modelling and simulation framework enables mechanistic investigations into patho-physiological electrophysiological and mechanical behaviour and can serve as testbed to guide the optimization of pharmacological and electrical therapies., This work was funded by a Wellcome Trust Fellowship in Basic Biomedical Sciences to B.R. (214290/Z/18/Z), Personalised In-Silico Cardiology (PIC) project, European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement 764738, the CompBioMed 1 and 2 Centre of Excellence in Computational Biomedicine (European Commission Horizon 2020 research and innovation programme, grant agreements No. 675451 and No. 823712), an NC3Rs Infrastructure for Impact Award (NC/P001076/1), the TransQST project (Innovative Medicines Initiative 2 Joint Undertaking under grant agreement No 116030, receiving support from the European Union’s Horizon 2020 research and innovation programme and EFPIA), and the Oxford BHF Centre of Research Excellence (RE/13/1/30181). This paper is part of a supplement supported by an unrestricted grant from the Theo-Rossi di Montelera (TRM) foundation., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Dynamic resource allocation for efficient parallel CFD simulations

  • Houzeaux, Guillaume|||0000-0002-2592-1426
  • Badia Sala, Rosa Maria|||0000-0003-2941-5499
  • Borrell Pol, Ricard
  • Dosimont, Damien
  • Ejarque Artigas, Jorge
  • Garcia Gasulla, Marta|||0000-0003-3682-9905
  • López Herrero, Víctor
CFD users of supercomputers usually resort to rule-of-thumb methods to select the number of subdomains (partitions) when relying on MPI-based parallelization. One common approach is to set a minimum number of elements or cells per subdomain, under which the parallel efficiency of the code is “known” to fall below a subjective level, say 80%. The situation is even worse when the user is not aware of the “good” practices for the given code and a huge amount of resources can thus be wasted. This work presents an elastic computing methodology that adapts at runtime the resources allocated to a simulation automatically. The criterion to control the required resources is based on a runtime measure of the communication efficiency of the execution. According to some analytical estimates, the resources are then expanded or reduced to fulfill this criterion and eventually execute an efficient simulation., This work has been supported by the Spanish Government (PID2019- 107255GB); by Generalitat de Catalunya (contract 2014-SGR-1051); by the European Commission H2020 project POP CoE (GA n. 824080); by the European Commission H2020 project CompBioMed CoE (GA n. 823712) and by the European Commission and the EuroHPC JU under contract 955558 (eFlows4HPC project)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Fluid–structure interaction analysis of eccentricity and leaflet rigidity on thrombosis biomarkers in bioprosthetic aortic valve replacements

  • Oks, David|||0000-0002-9659-0484
  • Samaniego Alvarado, Cristóbal
  • Houzeaux, Guillaume|||0000-0002-2592-1426
  • Butakoff, Constantine
  • Vázquez, Mariano|||0000-0002-2526-6708
This work intends to study the effect of aortic annulus eccentricity and leaflet rigidity on the performance, thrombogenic risk and calcification risk in bioprosthetic aortic valve replacements (BAVRs). To address these questions, a two-way immersed fluid–structure interaction (FSI) computational model was implemented in a high-performance computing (HPC) multi-physics simulation software, and validated against a well-known FSI benchmark. The aortic valve bioprosthesis model is qualitatively contrasted against experimental data, showing good agreement in closed and open states. Regarding the performance of BAVRs, the model predicts that increasing eccentricities yield lower geometric orifice areas (GOAs) and higher normalized transvalvular pressure gradients (TPGs) for healthy cardiac outputs during systole, agreeing with in vitro experiments. Regions with peak values of residence time are observed to grow with eccentricity in the sinus of Valsalva, indicating an elevated risk of thrombus formation for eccentric configurations. In addition, the computational model is used to analyze the effect of varying leaflet rigidity on both performance, thrombogenic and calcification risks with applications to tissue-engineered prostheses. For more rigid leaflets it predicts an increase in systolic and diastolic TPGs, and decrease in systolic GOA, which translates to decreased valve performance. The peak shear rate and residence time regions increase with leaflet rigidity, but their volume-averaged values were not significantly affected. Peak solid stresses are also analyzed, and observed to increase with rigidity, elevating risk of valve calcification and structural failure. To the authors' knowledge this is the first computational FSI model to study the effect of eccentricity or leaflet rigidity on thrombogenic biomarkers, providing a novel tool to aid device manufacturers and clinical practitioners., This project has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 713673. The research leading to these results has also received funding from “la Caixa” Foundation, with fellowship ID: LCF/BQ/DI18/11660044, and has been co-funded by the project CompBioMed2 (H2020-EU.1.4.1.3. Grant No. 823712), Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Time-efficient three-dimensional transmural scar assessment provides relevant substrate characterization for ventricular tachycardia features and long-term recurrences in ischemic cardiomyopathy

  • Merino Caviedes, Susana
  • Gutierrez, Lilian K.
  • Alfonso Almazán, José Manuel
  • Sanz Estébanez, Santiago
  • Cordero Grande, Lucilio
  • López Yunta, Mariña
  • Vázquez, Mariano|||0000-0002-2526-6708
  • Aguado Sierra, Jazmín|||0000-0002-9711-3225
Delayed gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) imaging requires novel and time-efficient approaches to characterize the myocardial substrate associated with ventricular arrhythmia in patients with ischemic cardiomyopathy. Using a translational approach in pigs and patients with established myocardial infarction, we tested and validated a novel 3D methodology to assess ventricular scar using custom transmural criteria and a semiautomatic approach to obtain transmural scar maps in ventricular models reconstructed from both 3D-acquired and 3D-upsampled-2D-acquired LGE-CMR images. The results showed that 3D-upsampled models from 2D LGE-CMR images provided a time-efficient alternative to 3D-acquired sequences to assess the myocardial substrate associated with ischemic cardiomyopathy. Scar assessment from 2D-LGE-CMR sequences using 3D-upsampled models was superior to conventional 2D assessment to identify scar sizes associated with the cycle length of spontaneous ventricular tachycardia episodes and long-term ventricular tachycardia recurrences after catheter ablation. This novel methodology may represent an efficient approach in clinical practice after manual or automatic segmentation of myocardial borders in a small number of conventional 2D LGE-CMR slices and automatic scar detection., The Centro Nacional de Investigaciones Cardiovasculares (CNIC) is supported by the Instituto de Salud Carlos III (ISCIII), the Ministerio de Ciencia e Innovación and the ProCNIC Foundation (Madrid, Spain). The CNIC and the Barcelona Supercomputing Center (BSC, Barcelona, Spain) are Severo Ochoa Centers of Excellence (SEV-2015-0505 and SEV-2011-0067, respectively). This study was also supported by grants from the Fondo Europeo de Desarrollo Regional (CB16/11/00458), the Ministerio de Ciencia e Innovación (PID2019-109329RB-I00) and the Heart Rhythm Association of the Spanish Society of Cardiology (ARC). The study was also part of a Master Research Agreement between CNIC and Philips Healthcare. The study was partially supported by the Fundación Interhospitalaria para la Investigación Cardiovascular (FIC, Madrid, Spain) and the Fundación Eugenio Rodríguez Pascual (Madrid, Spain). J.A.-S. is funded by the CompBioMed2 project grant agreement 823712, H2020-EU.1.4.1.3 European Union’s Horizon 2020 research and innovation program, the SILICOFCM project, grant agreement 777204, H2020-EU.3.1.5 and by a Ramón y Cajal fellowship (RYC-2017-22532), MINECO, Spain. L.K.G was funded by the Fundación Carolina-BBVA. Grant TEC2017-82408-R is also acknowledged., Peer Reviewed, "Article signat per 25 autors/es: Susana Merino-Caviedes, Lilian K. Gutierrez, José Manuel Alfonso-Almazán, Santiago Sanz-Estébanez, Lucilio Cordero-Grande, Jorge G. Quintanilla, Javier Sánchez-González, Manuel Marina-Breysse, Carlos Galán-Arriola, Daniel Enríquez-Vázquez, Carlos Torres, Gonzalo Pizarro, Borja Ibáñez, Rafael Peinado, Jose Luis Merino, Julián Pérez-Villacastín, José Jalife, Mariña López-Yunta, Mariano Vázquez, Jazmín Aguado-Sierra, Juan José González-Ferrer, Nicasio Pérez-Castellano, Marcos Martín-Fernández, Carlos Alberola-López & David Filgueiras-Rama"
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

HPC compact quasi-Newton algorithm for interface problems

  • Santiago, Alfonso|||0000-0002-9374-1275
  • Zavala Aké, Miguel
  • Borrell Pol, Ricard
  • Houzeaux, Guillaume|||0000-0002-2592-1426
  • Vázquez, Mariano|||0000-0002-2526-6708
In this work we present a robust interface coupling algorithm called Compact Interface quasi-Newton (CIQN). It is designed for computationally intensive applications using an MPI multi-code partitioned scheme. The algorithm allows to reuse information from previous time steps, feature that has been previously proposed to accelerate convergence. Through algebraic manipulation, an efficient usage of the computational resources is achieved by: avoiding construction of dense matrices and reduce every multiplication to a matrix–vector product and reusing the computationally expensive loops. This leads to a compact version of the original quasi-Newton algorithm. Altogether with an efficient communication, in this paper we show an efficient scalability up to 4800 cores. Three examples with qualitatively different dynamics are shown to prove that the algorithm can efficiently deal with added mass instability and two-field coupled problems. We also show how reusing histories and filtering does not necessarily makes a more robust scheme and, finally, we prove the necessity of this HPC version of the algorithm. The novelty of this article lies in the HPC focused implementation of the algorithm, detailing how to fuse and combine the composing blocks to obtain an scalable MPI implementation. Such an implementation is mandatory in large scale cases, for which the contact surface cannot be stored in a single computational node, or the number of contact nodes is not negligible compared with the size of the domain., This work has been funded by CompBioMed project a grant by the EuropeanCommission H2020 (agreement nr: 823712), EUBrazilCC a project under the Programme FP7-ICT (agreement nr: 614048) and a FPI-SO grant (agreementnr: SVP-2014-068491, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Virtual clinical QT exposure-response studies – A translational computational approach

  • Aguado Sierra, Jazmín|||0000-0002-9711-3225
  • Dominguez Gomez, Paula
  • Amar, Ani
  • Butakoff, Constantine
  • Leitner, Michael
  • Schaper, Stefan
  • Kriegl, Jan M.
  • Darpo, Borje
  • Vázquez, Mariano|||0000-0002-2526-6708
  • Rast, Georg
Background and purpose A recent paradigm shift in proarrhythmic risk assessment suggests that the integration of clinical, non-clinical, and computational evidence can be used to reach a comprehensive understanding of the proarrhythmic potential of drug candidates. While current computational methodologies focus on predicting the incidence of proarrhythmic events after drug administration, the objective of this study is to predict concentration-response relationships of QTc as a clinical endpoint. Experimental approach Full heart computational models reproducing human cardiac populations were created to predict the concentration-response relationship of changes in the QT interval as recommended for clinical trials. The concentration-response relationship of the QT-interval prolongation obtained from the computational cardiac population was compared against the relationship from clinical trial data for a set of well-characterized compounds: moxifloxacin, dofetilide, verapamil, and ondansetron. Key results Computationally derived concentration–response relationships of QT interval changes for three of the four drugs had slopes within the confidence interval of clinical trials (dofetilide, moxifloxacin and verapamil) when compared to placebo-corrected concentration-ΔQT and concentration-ΔQT regressions. Moxifloxacin showed a higher intercept, outside the confidence interval of the clinical data, demonstrating that in this example, the standard linear regression does not appropriately capture the concentration-response reulsts at very low concentrations. The concentrations corresponding to a mean QTc prolongation of 10 ms were consistently lower in the computational model than in clinical data. The critical concentration varied within an approximate ratio of 0.5 (moxifloxacin and ondansetron) and 1 times (dofetilide, verapamil) the critical concentration observed in human clinical trials. Notably, no other in silico methodology can approximate the human critical concentration values for a QT interval prolongation of 10 ms. Conclusion and implications Computational concentration-response modelling of a virtual population of high-resolution, 3-dimensional cardiac models can provide comparable information to clinical data and could be used to complement pre-clinical and clinical safety packages. It provides access to an unlimited exposure range to support trial design and can improve the understanding of pre-clinical-clinical translation., JA-S is funded by a Ramon y Cajal fellowship (RYC-2017-22,532), Ministerio de Ciencia e Innovacion, Spain; and by Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion (meHeart ME PID2019-104356RB-C44). CB is funded by the Torres Quevedo Program (PTQ2018–010290), Ministerio de Ciencia e Innovacion, Spain. AA is funded by the Torres Quevedo Program (PTQ2020–011408), Ministerio de Ciencia e Innovacion, Spain. JA-S, and MV are supported by the European Union's Horizon 2020 research and innovation programme under grant agreements No. 823712 (CompBioMed project, phase 2) and No. 951773 (PerMedCoE). Elem Biotech research staff was supported by the RED.ES Spanish programme, under grant reference No 2021/C005/00149823, during the development phase of the project., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

  • Santiago, Alfonso|||0000-0002-9374-1275
  • Butakoff, Constantine
  • Eguzkitza, Beatriz|||0000-0002-3302-6667
  • Gray, Richard A.
  • May-Newman, Karen
  • Pathmanathan, Pras
  • Vu, Vi
  • Vázquez, Mariano|||0000-0002-2526-6708
BACKGROUND: Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. METHODS: The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow , maximum aortic root flow , average LVAD flow , and maximum LVAD flow ); (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. RESULTS: Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. Conclusions This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive., This project was funded in part by the FDA Critical Path Initiative and by an appointment to the Research Participation Program at the Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, administered by the Oak Ridge Institute for Science, and Education through an interagency agreement between the U.S. Department of Energy and FDA to RAG. MV and AS acknowledge the funding from the project CompBioMed2 (H2020-EU.1.4.1.3. Grant number: 823712), SilicoFCM (H2020-EU.3.1.5. Grant number: 777204), and NEOTEC 2019 - "Generador de Corazones Virtuales" (“Ministerio de Economía y competititvidad”, EXP - 00123159 / SNEO-20191113). AS salary is partially funded by the “Ministerio de Economía y competititvidad” under the Torres Quevedo Program (grant number: PTQ2019-010528). CB salary is partially funded by the Torres Quevedo Program (grant number: PTQ2018-010290). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript., Peer Reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The ''Digital Twin'' to enable the vision of precision cardiology

  • Corral-Acero, J.
  • Margara, F.
  • Marciniak, M.
  • Rodero, C.
  • Loncaric, F.
  • Feng, Y.
  • Gilbert, A.
  • Fernandes, J.F.
  • Bukhari, H.A.
  • Wajdan, A.
  • Martinez, M.V.
  • Santos, M.S.
  • Shamohammdi, M.
  • Luo, H.
  • Westphal, P.
  • Leeson, P.
  • DiAchille, P.
  • Gurev, V.
  • Mayr, M.
  • Geris, L.
  • Pathmanathan, P.
  • Morrison, T.
  • Cornelussen, R.
  • Prinzen, F.
  • Delhaas, T.
  • Doltra, A.
  • Sitges, M.
  • Vigmond, E.J.
  • Zacur, E.
  • Grau, V.
  • Rodriguez, B.
  • Remme, E.W.
  • Niederer, S.
  • Mortier, P.
  • McLeod, K.
  • Potse, M.
  • Pueyo, E.
  • Bueno-Orovio, A.
  • Lamata, P.
Providing therapies tailored to each patient is the vision of precision medicine, enabled by the increasing ability to capture extensive data about individual patients. In this position paper, we argue that the second enabling pillar towards this vision is the increasing power of computers and algorithms to learn, reason, and build the ''digital twin'' of a patient. Computational models are boosting the capacity to draw diagnosis and prognosis, and future treatments will be tailored not only to current health status and data, but also to an accurate projection of the pathways to restore health by model predictions. The early steps of the digital twin in the area of cardiovascular medicine are reviewed in this article, together with a discussion of the challenges and opportunities ahead. We emphasize the synergies between mechanistic and statistical models in accelerating cardiovascular research and enabling the vision of precision medicine.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modelización computacional cardiaca

  • Bragard, J.R.
  • Camara, O.
  • Echebarria, B.
  • Gerardo Giorda, L.
  • Pueyo, E.
  • Saiz, J.
  • Sebastián, R.
  • Soudah, E.
  • Vázquez, M.
Cardiovascular diseases currently have a major social and economic impact, constituting one of the leading causes of mortality and morbidity. Personalized computational models of the heart are demonstrating their usefulness both to help understand the mechanisms underlying cardiac disease, and to optimize their treatment and predict the patient''s response. Within this framework, the Spanish Research Network for Cardiac Computational Modelling (VHeart-SN) has been launched. The general objective of the VHeart-SN network is the development of an integrated, modular and multiscale multiphysical computational model of the heart. This general objective is addressed through the following specific objectives: a) to integrate the different numerical methods and models taking into account the specificity of patients; b) to assist in advancing knowledge of the mechanisms associated with cardiac and vascular diseases; and c) to support the application of different personalized therapies. This article presents the current state of cardiac computational modelling and different scientific works conducted by the members of the network to gain greater understanding of the characteristics and usefulness of these models.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Toward cardiac electrophysiology digital twins with an efficient open source scalable solver on GPU clusters

  • Berg, Lucas Arantes
  • Oliveira, Rafael Sachetto
  • Camps, Julia
  • de Lima, Lucas Marins Ramalho
  • de Oliveira Campos, Joventino
  • Wang, Zhinuo Jenny
  • Doste, Ruben
  • Bueno-Orovio, Alfonso
  • dos Santos, Rodrigo Weber
  • Rodriguez, Blanca
Modelling and simulation are essential in biomedicine, and specifically in computational cardiology. Reliable, efficient and accurate solvers are critical. This study presents an open-source, GPU-based cardiac electrophysiology solver for scalable multiscale simulations (monoalg3d), incorporating conduction system calibration and performance optimization. The solver employs the monodomain equation coupled with the Purkinje network, solved via the finite volume method, featuring a GPU-based linear solver and concurrent simulation dispatch with MPI. We demonstrate a speedup over a CPU-based solution and scalability by running 512 simulations on 128 compute nodes. Coarse and fine biventricular mesh simulations with 855, 670 and 6, 845, 360 control volumes are completed in less than 24 min and 303 min, respectively, considering a single beat and a human-based ventricular cellular model with 43 state variables. The proposed open-source solver enhances computational efficiency and physiological fidelity through Purkinje-muscle-junction calibration, enabling large-scale, high-speed cardiac simulations including the conduction system. This work marks a significant step toward fast and scalable cardiac simulations on GPU architectures by providing execution of concurrent simulations with the novel MPI batch feature and calibration of Purkinje coupling parameters, paving the way for integration into a Digital Twin personalisation pipeline, including the conduction system., This work was funded by a Wellcome Trust fellowship in Basic Biomedical Sciences to B.R. (214290/Z/18/Z), the EPSRC project CompBioMedX (EP/X019446/1), the CompBioMed2 Centre of Excellence in Computational Biomedicine grant agreements No. 675451 and No. 823712. L.A.B acknowledges support from CNPq grant No. 446127/2024-8 and the Federal University of Juiz de Fora. R.S.O. acknowledges support from Fapemig grant No. APQ-00748-18 and UFSJ. R.W.S. acknowledges support from Fapemig grant APQ-02445-24, 'Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior' (CAPES), 'Financiadora de Estudos e Projetos' (Finep), National Council for Scientific and Technological Development (CNPq), the National Laboratory for Scientific Computing (LNCC/MCTI, Brazil) for providing HPC resources of the SDumont supercomputer SINAPAD, and the Federal University of Juiz de Fora (UFJF). A.B.O. acknowledges support from UK Research and Innovation grant No. 10110728. The U.S. Department of Energy's (DOE) Innovative and Novel Computational Impact on Theory and Experiment (INCITE) Program awarded access to Polaris, under contract No. DE-AC02-06CH11357. The project that gave rise to these results received the support of a fellowship from 'la Caixa' Foundation (ID 100010434) to J.C. (code LCF/BQ/PI25/12100029). For the purpose of open access, the authors have applied a Creative Commons Attribution (CC BY) public copyright licence to any Author Accepted Manuscript version arising from this submission.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Ventricular anatomical complexity and sex differences impact predictions from electrophysiological computational models

  • Gonzalez Martin, Pablo
  • Sacco, Federica
  • Butakoff, Constantine
  • Doste Beltrán, Rubén
  • Bederian, Carlos
  • Gutierrez Espinosa de los Monteros, Lilian K.
  • Houzeaux, Guillaume
  • Iaizzo, Paul A.
  • Iles, Tinen L.
  • Vázquez, Mariano
  • Aguado-Sierra, Jazmin
Includes supplementary materials for the online appendix., The aim of this work was to analyze the influence of sex hormones and anatomical details (trabeculations and false tendons) on the electrophysiology of healthy human hearts. Additionally, sex- and anatomy-dependent effects of ventricular tachycardia (VT) inducibility are presented. To this end, four anatomically normal, human, biventricular geometries (two male, two female), with identifiable trabeculations, were obtained from high-resolution, ex-vivo MRI and represented by detailed and smoothed geometrical models (with and without the trabeculations). Additionally one model was augmented by a scar. The electrophysiology finite element model (FEM) simulations were carried out, using O’Hara-Rudy human myocyte model with sex phenotypes of Yang and Clancy. A systematic comparison between detailed vs smooth anatomies, male vs female normal hearts was carried out. The heart with a myocardial infarction was subjected to a programmed stimulus protocol to identify the effects of sex and anatomical detail on ventricular tachycardia inducibility. All female hearts presented QT-interval prolongation however the prolongation interval in comparison to the male phenotypes was anatomy-dependent and was not correlated to the size of the heart. Detailed geometries showed QRS fractionation and increased T-wave magnitude in comparison to the corresponding smoothed geometries. A variety of sustained VTs were obtained in the detailed and smoothed male geometries at different pacing locations, which provide evidence of the geometry-dependent differences regarding the prediction of the locations of reentry channels. In the female phenotype, sustained VTs were induced in both detailed and smooth geometries with RV apex pacing, however no consistent reentry channels were identified. Anatomical and physiological cardiac features play an important role defining risk in cardiac disease. These are often excluded from cardiac electrophysiology simulations. The assumption that the cardiac endocardium is smooth may produce inaccurate predictions towards the location of reentry channels in in-silico tachycardia inducibility studies., JA-S, FS, GH and MV are supported by the European Union’s Horizon 2020 research and innovation programme under grant agreements No 675451 (Compbiomed project phase 1) and No 823712 (CompBioMed project, phase 2) and project No 777204 (SilicoFCM project). Part of the simulation computing hours were provided by the CompBioMed project phase 1. JA-S was awarded computation time from Red Espanola de Supercomputacion (RES). (Activity IDs: FI-2018-2-0049 and BCV-2019-2-0014) JA-S is funded by a Ramon y Cajal fellowship (RYC-2017-22532), Ministerio de Ciencia e Innovacion, Spain; and by Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion 2017-2020 from the Ministerio de Ciencia e Innovacion y Universidades (PID2019-104356RBC41/AEI/10.13039/501100011033): meHeart ME PID2019-104356RB-C44. CB is funded by the Torres Quevedo Program (PTQ2018-010290), Ministerio de Ciencia e Innovacion, Spain. MV, GH and CB are funded by the Spanish Neotec project EXP - 00123159/SNEO-20191113 Generador de corazones virtuales. LKGM was funded by Fundacion Carolina-BBVA. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. There was no additional external funding received for this study.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Fluid–structure interaction simulations outperform computational fluid dynamics in the description of thoracic aorta haemodynamics and in the differentiation of progressive dilation in Marfan syndrome patients

  • Pons, Ramón
  • Cajas, Juan Carlos
  • Rodríguez-Palomares, José F.
  • Guala, Andrea
  • Dux-Santoy, Lydia
  • Teixidó-Tura, Gisela
  • Molins, José Javier
  • Vázquez, Mariano
  • Evangelista, Arturo
  • Martorell, Jordi
Abnormal fluid dynamics at the ascending aorta may be at the origin of aortic aneurysms. This study was aimed at comparing the performance of computational fluid dynamics (CFD) and fluid–structure interaction (FSI) simulations against four-dimensional (4D) flow magnetic resonance imaging (MRI) data; and to assess the capacity of advanced fluid dynamics markers to stratify aneurysm progression risk. Eight Marfan syndrome (MFS) patients, four with stable and four with dilating aneurysms of the proximal aorta, and four healthy controls were studied. FSI and CFD simulations were performed with MRI-derived geometry, inlet velocity field and Young's modulus. Flow displacement, jet angle and maximum velocity evaluated from FSI and CFD simulations were compared to 4D flow MRI data. A dimensionless parameter, the shear stress ratio (SSR), was evaluated from FSI and CFD simulations and assessed as potential correlate of aneurysm progression. FSI simulations successfully matched MRI data regarding descending to ascending aorta flow rates (R2 = 0.92) and pulse wave velocity (R2 = 0.99). Compared to CFD, FSI simulations showed significantly lower percentage errors in ascending and descending aorta in flow displacement (−46% ascending, −41% descending), jet angle (−28% ascending, −50% descending) and maximum velocity (−37% ascending, −34% descending) with respect to 4D flow MRI. FSI- but not CFD-derived SSR differentiated between stable and dilating MFS patients. Fluid dynamic simulations of the thoracic aorta require fluid–solid interaction to properly reproduce complex haemodynamics. FSI- but not CFD-derived SSR could help stratifying MFS patients., This study was funded by Ministerio de Economía y Competitividad (grant no. RTC-2016-5152-1), Fundació la Marató de TV3 (grant no. 20151330), FP7 People: Marie-Curie Actions (grant no. 267128), Instituto de Salud Carlos III (grant nos PI14/0106 and PI17/00381) and ‘la Caixa’ Foundation. M.V. was funded by CompBioMed2, grant agreement ID: 823712, funded under: H2020-EU.1.4.1.3; and SILICOFCM, grant agreement ID: 777204, funded under: H2020-EU.3.1.5., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Concomitant respiratory failure can impair myocardial oxygenation in patients with acute cardiogenic shock supported by VA-ECMO

  • Prisco, Anthony R.
  • Aguado Sierra, Jazmín
  • Butakoff, Constantine
  • Vázquez, Mariano
  • Houzeaux, Guillaume
  • Eguzkitza, Beatriz
  • Bartos, Jason A.
  • Yannopoulos, Demetris
  • Raveendran, Ganesh
  • Holm, Mikayle
  • Iles, Tinen
  • Mahr, Claudius
  • Iaizzo, Paul A.
Venous-arterial extracorporeal membrane oxygenation (VA-ECMO) treatment for acute cardiogenic shock in patients who also have acute lung injury predisposes development of a serious complication called “north-south syndrome” (NSS) which causes cerebral hypoxia. NSS is poorly characterized and hemodynamic studies have focused on cerebral perfusion ignoring the heart. We hypothesized in NSS the heart would be more likely to receive hypoxemic blood than the brain due to the proximity of the coronary arteries to the aortic annulus. To test this, we conducted a computational fluid dynamics simulation of blood flow in a human supported by VA-ECMO. Simulations quantified the fraction of blood at each aortic branching vessel originating from residual native cardiac output versus VA-ECMO. As residual cardiac function was increased, simulations demonstrated myocardial hypoxia would develop prior to cerebral hypoxia. These results illustrate the conditions where NSS will develop and the relative cardiac function that will lead to organ-specific hypoxia., This work was supported in part by the University of Minnesota’s Medical School Academic Investment Education Program grant and the Institute for Engineering in Medicine. We also acknowledge the Partnership for Advanced Computing in Europe (PRACE) for awarding us access to Joliot-Curie Rome supercomputer at Bruyères-le-Châtel, under the project Cardiovascular-COVID. Additionally, we would like to acknowledge the Torres Quevedo Program, the Ramón y Cajal Program, and the European Institute of Innovation and Technology for support., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

PlayMolecule glimpse: understanding protein-ligand property predictions with interpretable neural networks

  • Varela-Rial, Alejandro
  • Maryanow, Iain
  • Majewski, Maciej
  • Doerr, Stefan, 1987-
  • Schapin, Nikolai
  • Jiménez Luna, José, 1993-
  • De Fabritiis, Gianni
Deep learning has been successfully applied to structure-based protein-ligand affinity prediction, yet the black box nature of these models raises some questions. In a previous study, we presented KDEEP, a convolutional neural network that predicted the binding affinity of a given protein-ligand complex while reaching state-of-the-art performance. However, it was unclear what this model was learning. In this work, we present a new application to visualize the contribution of each input atom to the prediction made by the convolutional neural network, aiding in the interpretability of such predictions. The results suggest that KDEEP is able to learn meaningful chemistry signals from the data, but it has also exposed the inaccuracies of the current model, serving as a guideline for further optimization of our prediction tools., The authors thank Acellera Ltd. for funding. G.D.F. acknowledges support from PID2020-116564GB-I00/MICIN/AEI/10.13039/501100011033 Ministerio de Ciencia e Innovación. This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 823712 (CompBioMed2) and from the Industrial Doctorates Plan of the Secretariat of Universities and Research of the Department of Economy and Knowledge of the Generalitat of Catalonia.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

NNP/MM: Accelerating molecular dynamics simulations with machine learning potentials and molecular mechanics

  • Galvelis, Raimondas
  • Varela-Rial, Alejandro
  • Doerr, Stefan, 1987-
  • Fino, Roberto
  • Eastman, Peter
  • Markland, Thomas E.
  • Chodera, John D.
  • De Fabritiis, Gianni
Machine learning potentials have emerged as a means to enhance the accuracy of biomolecular simulations. However, their application is constrained by the significant computational cost arising from the vast number of parameters compared with traditional molecular mechanics. To tackle this issue, we introduce an optimized implementation of the hybrid method (NNP/MM), which combines a neural network potential (NNP) and molecular mechanics (MM). This approach models a portion of the system, such as a small molecule, using NNP while employing MM for the remaining system to boost efficiency. By conducting molecular dynamics (MD) simulations on various protein-ligand complexes and metadynamics (MTD) simulations on a ligand, we showcase the capabilities of our implementation of NNP/MM. It has enabled us to increase the simulation speed by ∼5 times and achieve a combined sampling of 1 μs for each complex, marking the longest simulations ever reported for this class of simulations., The authors thank the volunteers of GPUGRID.net for donating computing time. This project has received funding from the Torres-Quevedo Programme from the Spanish National Agency for Research (No. PTQ-17-09078/AEI/10.13039/501100011033) (R.G.); the European Union’s Horizon 2020 research and innovation programme, under Grant Agreement No. 823712 (R.G., A.V.-R., R.F.); the Industrial Doctorates Plan of the Secretariat of Universities and Research of the Department of Economy and Knowledge of the Generalitat of Catalonia (A.V.-R.); the Chan Zuckerberg Initiative DAF (Grant No. 2020-219414), an advised fund of Silicon Valley Community Foundation (S.D., P.E.); and the project PID2020-116564GB-I00 has been funded by MCIN/AEI/10.13039/501100011033. Research reported in this publication was supported by the National Institute of General Medical Sciences (NIGMS) of the National Institutes of Health, under Award No. GM140090 (P.E., T.E.M., J.D.C., G.D.F.). This research was funded in part through the NIH/NCI Cancer Center Support Grant P30 CA008748 (J.D.C.). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

HPC compact quasi-Newton algorithm for interface problems

  • Santiago, Alfonso
  • Zavala Aké, Miguel
  • Borrell Pol, Ricard
  • Houzeaux, Guillaume
  • Vázquez, Mariano
In this work we present a robust interface coupling algorithm called Compact Interface quasi-Newton (CIQN). It is designed for computationally intensive applications using an MPI multi-code partitioned scheme. The algorithm allows to reuse information from previous time steps, feature that has been previously proposed to accelerate convergence. Through algebraic manipulation, an efficient usage of the computational resources is achieved by: avoiding construction of dense matrices and reduce every multiplication to a matrix–vector product and reusing the computationally expensive loops. This leads to a compact version of the original quasi-Newton algorithm. Altogether with an efficient communication, in this paper we show an efficient scalability up to 4800 cores. Three examples with qualitatively different dynamics are shown to prove that the algorithm can efficiently deal with added mass instability and two-field coupled problems. We also show how reusing histories and filtering does not necessarily makes a more robust scheme and, finally, we prove the necessity of this HPC version of the algorithm. The novelty of this article lies in the HPC focused implementation of the algorithm, detailing how to fuse and combine the composing blocks to obtain an scalable MPI implementation. Such an implementation is mandatory in large scale cases, for which the contact surface cannot be stored in a single computational node, or the number of contact nodes is not negligible compared with the size of the domain., This work has been funded by CompBioMed project a grant by the EuropeanCommission H2020 (agreement nr: 823712), EUBrazilCC a project under the Programme FP7-ICT (agreement nr: 614048) and a FPI-SO grant (agreementnr: SVP-2014-068491, Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Validation of the alchemical transfer method for the estimation of relative binding affinities of molecular series

  • Sabanés Zariquiey, Francesc
  • Pérez, Adrià
  • Majewski, Maciej
  • Gallicchio, Emilio
  • De Fabritiis, Gianni
The accurate prediction of protein-ligand binding affinities is crucial for drug discovery. Alchemical free energy calculations have become a popular tool for this purpose. However, the accuracy and reliability of these methods can vary depending on the methodology. In this study, we evaluate the performance of a relative binding free energy protocol based on the alchemical transfer method (ATM), a novel approach based on a coordinate transformation that swaps the positions of two ligands. The results show that ATM matches the performance of more complex free energy perturbation (FEP) methods in terms of Pearson correlation but with marginally higher mean absolute errors. This study shows that the ATM method is competitive compared to more traditional methods in speed and accuracy and offers the advantage of being applicable with any potential energy function., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 823712, and the project PID2020-116564GB-I00 has been funded by MCIN/AEI/10.13039/501100011033, the Torres-Quevedo Programme from the Spanish National Agency for Research (PTQ2020-011145/AEI/10.13039/501100011033). Research reported in this publication was supported by the National Institute of General Medical Sciences (NIGMS) of the National Institutes of Health under award number GM140090. E.G. acknowledges support from the United States’ National Science Foundation (NSF CAREER 1750511).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Enhancing protein-ligand binding affinity predictions using neural network potentials

  • Sabanés Zariquiey, Francesc
  • Galvelis, Raimondas
  • Gallicchio, Emilio
  • Chodera, John D.
  • Markland, Thomas E.
  • De Fabritiis, Gianni
This letter gives results on improving protein-ligand binding affinity predictions based on molecular dynamics simulations using machine learning potentials with a hybrid neural network potential and molecular mechanics methodology (NNP/MM). We compute relative binding free energies with the Alchemical Transfer Method and validate its performance against established benchmarks and find significant enhancements compared with conventional MM force fields like GAFF2., The authors thank the volunteers of GPUGRID.net for donating computing time. This project has received funding from the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 823712, and the project PID2020-116564GB-I00 has been funded by MCIN/AEI/10.13039/501100011033; the Torres-Quevedo Programme from the Spanish National Agency for Research (PTQ2020-011145/AEI/10.13039/501100011033). Research reported in this publication was supported by the National Institute of General Medical Sciences (NIGMS) of the National Institutes of Health under Award Number R01GM140090 to T.E.M., G.D.F., and J.D.C. E.G. acknowledges support from the United States National Science Foundation (NSF CAREER 1750511). J.D.C. also acknowledges support from NIH Grant P30CA008748 and the Sloan Kettering Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Characterization of partially ordered states in the intrinsically disordered N-terminal domain of p53 using millisecond molecular dynamics simulations

  • Herrera Nieto, Pablo, 1992-
  • Pérez, Adrià
  • De Fabritiis, Gianni
The exploration of intrinsically disordered proteins in isolation is a crucial step to understand their complex dynamical behavior. In particular, the emergence of partially ordered states has not been explored in depth. The experimental characterization of such partially ordered states remains elusive due to their transient nature. Molecular dynamics mitigates this limitation thanks to its capability to explore biologically relevant timescales while retaining atomistic resolution. Here, millisecond unbiased molecular dynamics simulations were performed in the exemplar N-terminal region of p53. In combination with state-of-the-art Markov state models, simulations revealed the existence of several partially ordered states accounting for [Formula: see text] 40% of the equilibrium population. Some of the most relevant states feature helical conformations similar to the bound structure of p53 to Mdm2, as well as novel [Formula: see text]-sheet elements. This highlights the potential complexity underlying the energy surface of intrinsically disordered proteins., The authors thank volunteers at GPUGRID.net for contributing with computational resources and Acellera for funding. G.D.F. acknowledges support from MINECO (Unidad de Excelencia María de Maeztu MDM-2014-0370 and BIO2017-82628-P) and FEDER. This project received funding from the European Union’s Horizon 2020 Research and Innovation Programme under Grant Agreement 823712 (CompBioMed2 Project).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Virtual clinical QT exposure-response studies – A translational computational approach

  • Aguado Sierra, Jazmín
  • Dominguez Gomez, Paula
  • Amar, Ani
  • Butakoff, Constantine
  • Leitner, Michael
  • Schaper, Stefan
  • Kriegl, Jan M.
  • Darpo, Borje
  • Vázquez, Mariano
  • Rast, Georg
Background and purpose A recent paradigm shift in proarrhythmic risk assessment suggests that the integration of clinical, non-clinical, and computational evidence can be used to reach a comprehensive understanding of the proarrhythmic potential of drug candidates. While current computational methodologies focus on predicting the incidence of proarrhythmic events after drug administration, the objective of this study is to predict concentration-response relationships of QTc as a clinical endpoint. Experimental approach Full heart computational models reproducing human cardiac populations were created to predict the concentration-response relationship of changes in the QT interval as recommended for clinical trials. The concentration-response relationship of the QT-interval prolongation obtained from the computational cardiac population was compared against the relationship from clinical trial data for a set of well-characterized compounds: moxifloxacin, dofetilide, verapamil, and ondansetron. Key results Computationally derived concentration–response relationships of QT interval changes for three of the four drugs had slopes within the confidence interval of clinical trials (dofetilide, moxifloxacin and verapamil) when compared to placebo-corrected concentration-ΔQT and concentration-ΔQT regressions. Moxifloxacin showed a higher intercept, outside the confidence interval of the clinical data, demonstrating that in this example, the standard linear regression does not appropriately capture the concentration-response reulsts at very low concentrations. The concentrations corresponding to a mean QTc prolongation of 10 ms were consistently lower in the computational model than in clinical data. The critical concentration varied within an approximate ratio of 0.5 (moxifloxacin and ondansetron) and 1 times (dofetilide, verapamil) the critical concentration observed in human clinical trials. Notably, no other in silico methodology can approximate the human critical concentration values for a QT interval prolongation of 10 ms. Conclusion and implications Computational concentration-response modelling of a virtual population of high-resolution, 3-dimensional cardiac models can provide comparable information to clinical data and could be used to complement pre-clinical and clinical safety packages. It provides access to an unlimited exposure range to support trial design and can improve the understanding of pre-clinical-clinical translation., JA-S is funded by a Ramon y Cajal fellowship (RYC-2017-22,532), Ministerio de Ciencia e Innovacion, Spain; and by Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion (meHeart ME PID2019-104356RB-C44). CB is funded by the Torres Quevedo Program (PTQ2018–010290), Ministerio de Ciencia e Innovacion, Spain. AA is funded by the Torres Quevedo Program (PTQ2020–011408), Ministerio de Ciencia e Innovacion, Spain. JA-S, and MV are supported by the European Union's Horizon 2020 research and innovation programme under grant agreements No. 823712 (CompBioMed project, phase 2) and No. 951773 (PerMedCoE). Elem Biotech research staff was supported by the RED.ES Spanish programme, under grant reference No 2021/C005/00149823, during the development phase of the project., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Time-efficient three-dimensional transmural scar assessment provides relevant substrate characterization for ventricular tachycardia features and long-term recurrences in ischemic cardiomyopathy

  • Merino Caviedes, Susana
  • Gutierrez, Lilian K.
  • Alfonso Almazán, José Manuel
  • Sanz Estébanez, Santiago
  • Cordero Grande, Lucilio
  • López Yunta, Mariña
  • Vázquez, Mariano
  • Aguado Sierra, Jazmín
Delayed gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) imaging requires novel and time-efficient approaches to characterize the myocardial substrate associated with ventricular arrhythmia in patients with ischemic cardiomyopathy. Using a translational approach in pigs and patients with established myocardial infarction, we tested and validated a novel 3D methodology to assess ventricular scar using custom transmural criteria and a semiautomatic approach to obtain transmural scar maps in ventricular models reconstructed from both 3D-acquired and 3D-upsampled-2D-acquired LGE-CMR images. The results showed that 3D-upsampled models from 2D LGE-CMR images provided a time-efficient alternative to 3D-acquired sequences to assess the myocardial substrate associated with ischemic cardiomyopathy. Scar assessment from 2D-LGE-CMR sequences using 3D-upsampled models was superior to conventional 2D assessment to identify scar sizes associated with the cycle length of spontaneous ventricular tachycardia episodes and long-term ventricular tachycardia recurrences after catheter ablation. This novel methodology may represent an efficient approach in clinical practice after manual or automatic segmentation of myocardial borders in a small number of conventional 2D LGE-CMR slices and automatic scar detection., The Centro Nacional de Investigaciones Cardiovasculares (CNIC) is supported by the Instituto de Salud Carlos III (ISCIII), the Ministerio de Ciencia e Innovación and the ProCNIC Foundation (Madrid, Spain). The CNIC and the Barcelona Supercomputing Center (BSC, Barcelona, Spain) are Severo Ochoa Centers of Excellence (SEV-2015-0505 and SEV-2011-0067, respectively). This study was also supported by grants from the Fondo Europeo de Desarrollo Regional (CB16/11/00458), the Ministerio de Ciencia e Innovación (PID2019-109329RB-I00) and the Heart Rhythm Association of the Spanish Society of Cardiology (ARC). The study was also part of a Master Research Agreement between CNIC and Philips Healthcare. The study was partially supported by the Fundación Interhospitalaria para la Investigación Cardiovascular (FIC, Madrid, Spain) and the Fundación Eugenio Rodríguez Pascual (Madrid, Spain). J.A.-S. is funded by the CompBioMed2 project grant agreement 823712, H2020-EU.1.4.1.3 European Union’s Horizon 2020 research and innovation program, the SILICOFCM project, grant agreement 777204, H2020-EU.3.1.5 and by a Ramón y Cajal fellowship (RYC-2017-22532), MINECO, Spain. L.K.G was funded by the Fundación Carolina-BBVA. Grant TEC2017-82408-R is also acknowledged., Peer Reviewed, "Article signat per 25 autors/es: Susana Merino-Caviedes, Lilian K. Gutierrez, José Manuel Alfonso-Almazán, Santiago Sanz-Estébanez, Lucilio Cordero-Grande, Jorge G. Quintanilla, Javier Sánchez-González, Manuel Marina-Breysse, Carlos Galán-Arriola, Daniel Enríquez-Vázquez, Carlos Torres, Gonzalo Pizarro, Borja Ibáñez, Rafael Peinado, Jose Luis Merino, Julián Pérez-Villacastín, José Jalife, Mariña López-Yunta, Mariano Vázquez, Jazmín Aguado-Sierra, Juan José González-Ferrer, Nicasio Pérez-Castellano, Marcos Martín-Fernández, Carlos Alberola-López & David Filgueiras-Rama", Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

  • Santiago, Alfonso
  • Butakoff, Constantine
  • Eguzkitza, Beatriz
  • Gray, Richard A.
  • May-Newman, Karen
  • Pathmanathan, Pras
  • Vu, Vi
  • Vázquez, Mariano
BACKGROUND: Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. METHODS: The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow , maximum aortic root flow , average LVAD flow , and maximum LVAD flow ); (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. RESULTS: Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. Conclusions This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive., This project was funded in part by the FDA Critical Path Initiative and by an appointment to the Research Participation Program at the Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, administered by the Oak Ridge Institute for Science, and Education through an interagency agreement between the U.S. Department of Energy and FDA to RAG. MV and AS acknowledge the funding from the project CompBioMed2 (H2020-EU.1.4.1.3. Grant number: 823712), SilicoFCM (H2020-EU.3.1.5. Grant number: 777204), and NEOTEC 2019 - "Generador de Corazones Virtuales" (“Ministerio de Economía y competititvidad”, EXP - 00123159 / SNEO-20191113). AS salary is partially funded by the “Ministerio de Economía y competititvidad” under the Torres Quevedo Program (grant number: PTQ2019-010528). CB salary is partially funded by the Torres Quevedo Program (grant number: PTQ2018-010290). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Ventricular anatomical complexity and sex differences impact predictions from electrophysiological computational models

  • Gonzalez Martin, Pablo
  • Sacco, Federica
  • Butakoff, Constantine
  • Doste, Ruben
  • Bederian, Carlos
  • Houzeaux, Guillaume
  • Vázquez, Mariano
  • Aguado Sierra, Jazmín
The aim of this work was to analyze the influence of sex hormones and anatomical details (trabeculations and false tendons) on the electrophysiology of healthy human hearts. Additionally, sex- and anatomy-dependent effects of ventricular tachycardia (VT) inducibility are presented. To this end, four anatomically normal, human, biventricular geometries (two male, two female), with identifiable trabeculations, were obtained from high-resolution, ex-vivo MRI and represented by detailed and smoothed geometrical models (with and without the trabeculations). Additionally one model was augmented by a scar. The electrophysiology finite element model (FEM) simulations were carried out, using O’Hara-Rudy human myocyte model with sex phenotypes of Yang and Clancy. A systematic comparison between detailed vs smooth anatomies, male vs female normal hearts was carried out. The heart with a myocardial infarction was subjected to a programmed stimulus protocol to identify the effects of sex and anatomical detail on ventricular tachycardia inducibility. All female hearts presented QT-interval prolongation however the prolongation interval in comparison to the male phenotypes was anatomy-dependent and was not correlated to the size of the heart. Detailed geometries showed QRS fractionation and increased T-wave magnitude in comparison to the corresponding smoothed geometries. A variety of sustained VTs were obtained in the detailed and smoothed male geometries at different pacing locations, which provide evidence of the geometry-dependent differences regarding the prediction of the locations of reentry channels. In the female phenotype, sustained VTs were induced in both detailed and smooth geometries with RV apex pacing, however no consistent reentry channels were identified. Anatomical and physiological cardiac features play an important role defining risk in cardiac disease. These are often excluded from cardiac electrophysiology simulations. The assumption that the cardiac endocardium is smooth may produce inaccurate predictions towards the location of reentry channels in in-silico tachycardia inducibility studies, JA-S, FS, GH and MV are supported by the European Union’s Horizon 2020 research and innovation programme under grant agreements No 675451 (Compbiomed project phase 1) and No 823712 (CompBioMed project, phase 2) and project No 777204 (SilicoFCM project). Part of the simulation computing hours were provided by the CompBioMed project phase 1. JA-S was awarded computation time from Red Espanola de Supercomputacion (RES). (Activity IDs: FI-2018-2-0049 and BCV-2019-2-0014) JA-S is funded by a Ramon y Cajal fellowship (RYC-2017-22532), Ministerio de Ciencia e Innovacion, Spain; and by Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion 2017-2020 from the Ministerio de Ciencia e Innovacion y Universidades (PID2019-104356RBC41/AEI/10.13039/501100011033): meHeart ME PID2019-104356RB-C44. CB is funded by the Torres Quevedo Program (PTQ2018-010290), Ministerio de Ciencia e Innovacion, Spain. MV, GH and CB are funded by the Spanish Neotec project EXP - 00123159/SNEO-20191113 Generador de corazones virtuales. LKGM was funded by Fundacion Carolina-BBVA. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. There was no additional external funding received for this study., Peer Reviewed, "Article signat per 11 autors/es: Pablo Gonzalez-Martin,Federica Sacco,Constantine Butakoff,Ruben Doste,Carlos Bederian,Lilian K. Gutierrez Espinosa de los Monteros,Guillaume Houzeaux,Paul A. Iaizzo,Tinen L. Iles,Mariano Vazquez,Jazmin Aguado-Sierra", Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Fluid-structure interaction simulations outperform computational fluid dynamics in the description of thoracic aorta haemodynamics and in the differentiation of progressive dilation in Marfan syndrome patients

  • Martorell López, Jordi
  • Molins, Jose Javier
  • Pons, R.
  • Guala, A.
  • Rodríguez-Palomares, J.F.
  • Cajas, J.C.
  • Dux-Santoy, L.
  • Teixidó-Tura, G.
  • Vázquez, M.
  • Evangelista, A.
Abnormal fluid dynamics at the ascending aorta may be at the origin of aortic aneurysms. This study was aimed at comparing the performance of computational fluid dynamics (CFD) and fluid–structure interaction (FSI) simulations against four-dimensional (4D) flow magnetic resonance imaging (MRI) data; and to assess the capacity of advanced fluid dynamics markers to stratify aneurysm progression risk. Eight Marfan syndrome (MFS) patients, four with stable and four with dilating aneurysms of the proximal aorta, and four healthy controls were studied. FSI and CFD simulations were performed with MRI-derived geometry, inlet velocity field and Young's modulus. Flow displacement, jet angle and maximum velocity evaluated from FSI and CFD simulations were compared to 4D flow MRI data. A dimensionless parameter, the shear stress ratio (SSR), was evaluated from FSI and CFD simulations and assessed as potential correlate of aneurysm progression. FSI simulations successfully matched MRI data regarding descending to ascending aorta flow rates (R2 = 0.92) and pulse wave velocity (R2 = 0.99). Compared to CFD, FSI simulations showed significantly lower percentage errors in ascending and descending aorta in flow displacement (−46% ascending, −41% descending), jet angle (−28% ascending, −50% descending) and maximum velocity (−37% ascending, −34% descending) with respect to 4D flow MRI. FSI- but not CFD-derived SSR differentiated between stable and dilating MFS patients. Fluid dynamic simulations of the thoracic aorta require fluid–solid interaction to properly reproduce complex haemodynamics. FSI- but not CFD-derived SSR could help stratifying MFS patients.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Equivariant graph neural networks for toxicity prediction

  • Cremer, Julian
  • Medrano Sandonas, Leonardo
  • Tkatchenko, Alexandre
  • Clevert, Djork-Arné
  • De Fabritiis, Gianni
Predictive modeling of toxicity is a crucial step in the drug discovery pipeline. It can help filter out molecules with a high probability of failing in the early stages of de novo drug design. Thus, several machine learning (ML) models have been developed to predict the toxicity of molecules by combining classical ML techniques or deep neural networks with well-known molecular representations such as fingerprints or 2D graphs. But the more natural, accurate representation of molecules is expected to be defined in physical 3D space like in ab initio methods. Recent studies successfully used equivariant graph neural networks (EGNNs) for representation learning based on 3D structures to predict quantum-mechanical properties of molecules. Inspired by this, we investigated the performance of EGNNs to construct reliable ML models for toxicity prediction. We used the equivariant transformer (ET) model in TorchMD-NET for this. Eleven toxicity data sets taken from MoleculeNet, TDCommons, and ToxBenchmark have been considered to evaluate the capability of ET for toxicity prediction. Our results show that ET adequately learns 3D representations of molecules that can successfully correlate with toxicity activity, achieving good accuracies on most data sets comparable to state-of-the-art models. We also test a physicochemical property, namely, the total energy of a molecule, to inform the toxicity prediction with a physical prior. However, our work suggests that these two properties can not be related. We also provide an attention weight analysis for helping to understand the toxicity prediction in 3D space and thus increase the explainability of the ML model. In summary, our findings offer promising insights considering 3D geometry information via EGNNs and provide a straightforward way to integrate molecular conformers into ML-based pipelines for predicting and investigating toxicity prediction in physical space. We expect that in the future, especially for larger, more diverse data sets, EGNNs will be an essential tool in this domain., This research used computational resources provided by the High-Performance Center (HPC) at the University of Luxembourg. J.C. received funding from the European Union’s Horizon 2020 research and innovation program under the Marie Skłodowska-Curie Actions grant agreement “Advanced machine learning for Innovative Drug Discovery (AIDD)” No. 956832. L.M.S. thanks S. Goger for fruitful discussions about the influence of functional groups in toxicity prediction. G.D.F. acknowledges funding from the European Union’s Horizon 2020 research and innovation program under Grant Agreement No. 823712; and the project PID2020-116564GB-I00 has been funded by MCIN/AEI/10.13039/501100011033.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Dynamic resource allocation for efficient parallel CFD simulations

  • Houzeaux, Guillaume
  • Badia Sala, Rosa Maria
  • Borrell Pol, Ricard
  • Dosimont, Damien
  • Ejarque Artigas, Jorge
  • Garcia Gasulla, Marta
  • López Herrero, Víctor
CFD users of supercomputers usually resort to rule-of-thumb methods to select the number of subdomains (partitions) when relying on MPI-based parallelization. One common approach is to set a minimum number of elements or cells per subdomain, under which the parallel efficiency of the code is “known” to fall below a subjective level, say 80%. The situation is even worse when the user is not aware of the “good” practices for the given code and a huge amount of resources can thus be wasted. This work presents an elastic computing methodology that adapts at runtime the resources allocated to a simulation automatically. The criterion to control the required resources is based on a runtime measure of the communication efficiency of the execution. According to some analytical estimates, the resources are then expanded or reduced to fulfill this criterion and eventually execute an efficient simulation., This work has been supported by the Spanish Government (PID2019- 107255GB); by Generalitat de Catalunya (contract 2014-SGR-1051); by the European Commission H2020 project POP CoE (GA n. 824080); by the European Commission H2020 project CompBioMed CoE (GA n. 823712) and by the European Commission and the EuroHPC JU under contract 955558 (eFlows4HPC project)., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Performance Assessment of an Electrostatic Filter-Diverter Stent Cerebrovascular Protection Device: Evaluation of a Range of Potential Electrostatic Fields Focusing on Small Particles

  • Eguzkitza, Beatriz
  • Navia, José A
  • Houzeaux, Guillaume
  • Butakoff, Constantine
  • Vázquez, Mariano
Silent Brain Infarction (SBI) is increasingly recognized in patients with cardiac conditions, particularly Atrial Fibrillation (AF) in elderly patients and those undergoing Transcatheter Aortic Valve Implantation (TAVI). While these infarcts often go unnoticed due to a lack of acute symptoms, they are associated with a threefold increase in stroke risk and are considered a precursor to ischemic stroke. Moreover, accumulating evidence suggests that SBI may contribute to the development of dementia, depression, and cognitive decline, particularly in the elderly population. The burden of SBI is substantial, with studies showing that up to 11 million Americans may experience a silent stroke annually. In AF patients, silent brain infarcts are common and can lead to progressive brain damage, even in those receiving anticoagulation therapy. The use of cerebral embolic protection devices (CEPDs) during TAVI has been explored to mitigate the risk of stroke; however, their efficacy remains under debate. Despite advancements in TAVI technology, cerebrovascular events, including silent brain lesions, continue to pose significant challenges, underscoring the need for improved preventive strategies and therapeutic approaches. We propose a device consisting of a strut structure placed at the base of the treated artery to model the potential risk of cerebral embolisms caused by atrial fibrillation, thromboembolism, or dislodged debris of varying potential TAVI patients. The study has been carried out in two stages. Both are based on computational fluid dynamics (CFD) coupled with the Lagrangian particle tracking method. The first stage of the work evaluates a variety of strut thicknesses and inter-strut spacings, contrasting with the device-free baseline geometry. The analysis is carried out by imposing flow rate waveforms characteristic of healthy and AF patients. Boundary conditions are calibrated to reproduce physiological flow rates and pressures in a patient’s aortic arch. In the second stage, the optimal geometric design from the first stage was employed, with the addition of lateral struts to prevent the filtration of particles and electronegatively charged strut surfaces, studying the effect of electrical forces on the clots if they are considered charged. Flowrate boundary conditions were used to emulate both healthy and AF conditions. Results from numerical simulations coming from the first stage indicate that the device blocks particles of sizes larger than the inter-strut spacing. It was found that lateral strut space had the highest impact on efficacy. Based on the results of the second stage, deploying the electronegatively charged device in all three aortic arch arteries, the number of particles entering these arteries was reduced on average by 62.6 % and 51.2 %, for the healthy and diseased models respectively, matching or surpassing current oral anticoagulant efficacy. In conclusion, the device demonstrated a two-fold mechanism for filtering emboli: (1) while the smallest particles are deflected by electrostatic repulsion, avoiding micro embolisms, which could lead to cognitive impairment, the largest ones are mechanically filtered since they cannot fit in between the struts, effectively blocking the full range of particle sizes analyzed in this study. The device presented in this manuscript offers an anticoagulant-free method to prevent stroke and SBIs, imperative given the growing population of AF and elderly patients., This work was partially financed by the European Project “An ecosystem for digital twins in healthcare (EDITH)” under the call: DIGITAL-2021-DEPLOY-01-TWINS-HEALTH, Ref: 101083771. The research has been also supported by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No. 713673, by the project CompBioMed2 (H2020-EU.1.4.1.3. Grant No. 823712), by CREXDATA project (HORIZON-CL4-2022-DATA-01. Grant No. 101092749), and by the EIC Accelerator grant “ELVIS—ELEM Virtual Heart Populations for Supercomputers” Grant ID 190134524., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Human biventricular electromechanical simulations on the progression of electrocardiographic and mechanical abnormalities in post-myocardial infarction

  • Wang, Zhinuo J
  • Santiago, Alfonso
  • Zhou, Xin
  • Wang, Lei
  • Margara, Francesca
  • Levrero-Florencio, Francesc
  • Das, Arka
  • Kelly, Chris
  • Dall'Armellina, Erica
  • Vázquez, Mariano
  • Rodriguez, Blanca
Aims Develop, calibrate and evaluate with clinical data a human electromechanical modelling and simulation framework for multiscale, mechanistic investigations in healthy and post-myocardial infarction (MI) conditions, from ionic to clinical biomarkers. Methods and results Human healthy and post-MI electromechanical simulations were conducted with a novel biventricular model, calibrated and evaluated with experimental and clinical data, including torso/biventricular anatomy from clinical magnetic resonance, state-of-the-art human-based membrane kinetics, excitation–contraction and active tension models, and orthotropic electromechanical coupling. Electromechanical remodelling of the infarct/ischaemic region and the border zone were simulated for ischaemic, acute, and chronic states in a fully transmural anterior infarct and a subendocardial anterior infarct. The results were compared with clinical electrocardiogram and left ventricular ejection fraction (LVEF) data at similar states. Healthy model simulations show LVEF 63%, with 11% peak systolic wall thickening, QRS duration and QT interval of 100 ms and 330 ms. LVEF in ischaemic, acute, and chronic post-MI states were 56%, 51%, and 52%, respectively. In linking the three post-MI simulations, it was apparent that elevated resting potential due to hyperkalaemia in the infarcted region led to ST-segment elevation, while a large repolarization gradient corresponded to T-wave inversion. Mechanically, the chronic stiffening of the infarct region had the benefit of improving systolic function by reducing infarct bulging at the expense of reducing diastolic function by inhibiting inflation. Conclusion Our human-based multiscale modelling and simulation framework enables mechanistic investigations into patho-physiological electrophysiological and mechanical behaviour and can serve as testbed to guide the optimization of pharmacological and electrical therapies., This work was funded by a Wellcome Trust Fellowship in Basic Biomedical Sciences to B.R. (214290/Z/18/Z), Personalised In-Silico Cardiology (PIC) project, European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement 764738, the CompBioMed 1 and 2 Centre of Excellence in Computational Biomedicine (European Commission Horizon 2020 research and innovation programme, grant agreements No. 675451 and No. 823712), an NC3Rs Infrastructure for Impact Award (NC/P001076/1), the TransQST project (Innovative Medicines Initiative 2 Joint Undertaking under grant agreement No 116030, receiving support from the European Union’s Horizon 2020 research and innovation programme and EFPIA), and the Oxford BHF Centre of Research Excellence (RE/13/1/30181). This paper is part of a supplement supported by an unrestricted grant from the Theo-Rossi di Montelera (TRM) foundation., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Machine learning coarse-grained potentials of protein thermodynamics

  • Majewski, Maciej
  • Pérez, Adrià
  • Thölke, Philipp
  • Doerr, Stefan, 1987-
  • Charron, Nicholas E.
  • Giorgino, Toni
  • Husic, Brooke E.
  • Clementi, Cecilia
  • Noé, Frank
  • De Fabritiis, Gianni
A generalized understanding of protein dynamics is an unsolved scientific problem, the solution of which is critical to the interpretation of the structure-function relationships that govern essential biological processes. Here, we approach this problem by constructing coarse-grained molecular potentials based on artificial neural networks and grounded in statistical mechanics. For training, we build a unique dataset of unbiased all-atom molecular dynamics simulations of approximately 9 ms for twelve different proteins with multiple secondary structure arrangements. The coarse-grained models are capable of accelerating the dynamics by more than three orders of magnitude while preserving the thermodynamics of the systems. Coarse-grained simulations identify relevant structural states in the ensemble with comparable energetics to the all-atom systems. Furthermore, we show that a single coarse-grained potential can integrate all twelve proteins and can capture experimental structural features of mutated proteins. These results indicate that machine learning coarse-grained potentials could provide a feasible approach to simulate and understand protein dynamics., The project PID2020-116564GB-I00 has been funded by MCIN/AEI/10.13039/501100011033 (G.D.F.) This project has received funding from the Torres-Quevedo Program from the Spanish National Agency for Research (PTQ2020-011145/AEI/10.13039/501100011033) (M.M.); the Torres-Quevedo Program from the Spanish National Agency for Research (PTQ2021-011669/AEI/10.13039/501100011033) (A.P.); the European Union’s Horizon 2020 research and innovation program under grant agreement No. 823712 (G.D.F.); NLM Training Program in Biomedical Informatics and Data Science (grant no. 5T15LM007093-27) (N.E.C.); Deutsche Forschungsgemeinschaft (DFG, GRK DAEDALUS, RTG 2433, Project Q05) (N.E.C.); National Science Foundation (CHE-1900374 and PHY-2019745) (C.C.); Einstein Foundation Berlin (Project 0420815101) (C.C.); Deutsche Forschungsgemeinschaft (DFG) SFB 1114 projects A04, B03, and B08, SFB/TRR 186 project A12, and SFB 1078 project C7 (C.C.); Deutsche Forschungsgemeinschaft (DFG) projects CRC1114/A04, CRC1114/C03 (F.N.); European Research Council (ERC) project ERG CoG 772230 (F.N.); Berlin Mathematics Center MATH+ project AA1-6 (F.N.); the National Institute of General Medical Sciences (NIGMS) of the National Institutes of Health under award number GM140090 (G.D.F.). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. The authors thank the volunteers of GPUGRID.net for donating computing time. T.G. acknowledges the CINECA award under the ISCRA initiative, for the availability of high performance computing resources and support. This project has received funding from the Spoke 7 of the National Centre for HPC, Big Data and Quantum Computing (CN00000013) of the NextGenerationEU initiative (T.G.).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Fluid–structure interaction analysis of eccentricity and leaflet rigidity on thrombosis biomarkers in bioprosthetic aortic valve replacements

  • Oks, David
  • Samaniego Alvarado, Cristóbal
  • Houzeaux, Guillaume
  • Butakoff, Constantine
  • Vázquez, Mariano
This work intends to study the effect of aortic annulus eccentricity and leaflet rigidity on the performance, thrombogenic risk and calcification risk in bioprosthetic aortic valve replacements (BAVRs). To address these questions, a two-way immersed fluid–structure interaction (FSI) computational model was implemented in a high-performance computing (HPC) multi-physics simulation software, and validated against a well-known FSI benchmark. The aortic valve bioprosthesis model is qualitatively contrasted against experimental data, showing good agreement in closed and open states. Regarding the performance of BAVRs, the model predicts that increasing eccentricities yield lower geometric orifice areas (GOAs) and higher normalized transvalvular pressure gradients (TPGs) for healthy cardiac outputs during systole, agreeing with in vitro experiments. Regions with peak values of residence time are observed to grow with eccentricity in the sinus of Valsalva, indicating an elevated risk of thrombus formation for eccentric configurations. In addition, the computational model is used to analyze the effect of varying leaflet rigidity on both performance, thrombogenic and calcification risks with applications to tissue-engineered prostheses. For more rigid leaflets it predicts an increase in systolic and diastolic TPGs, and decrease in systolic GOA, which translates to decreased valve performance. The peak shear rate and residence time regions increase with leaflet rigidity, but their volume-averaged values were not significantly affected. Peak solid stresses are also analyzed, and observed to increase with rigidity, elevating risk of valve calcification and structural failure. To the authors' knowledge this is the first computational FSI model to study the effect of eccentricity or leaflet rigidity on thrombogenic biomarkers, providing a novel tool to aid device manufacturers and clinical practitioners., This project has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 713673. The research leading to these results has also received funding from “la Caixa” Foundation, with fellowship ID: LCF/BQ/DI18/11660044, and has been co-funded by the project CompBioMed2 (H2020-EU.1.4.1.3. Grant No. 823712), Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Performance assessment of an electrostatic filter-diverter stent cerebrovascular protection device. Is it possible not to use anticoagulants in atrial fibrilation elderly patients?

  • Eguzkitza, Beatriz
  • Oks, David
  • Navia, José A.
  • Houzeaux, Guillaume
  • Butakoff, Constantine
  • Fisa, María
  • Campoy Millán, Ariadna
  • Vázquez, Mariano
Stroke is the second leading cause of death worldwide. Nearly two-thirds of strokes are produced by cardioembolisms, and half of cardioembolic strokes are triggered by Atrial Fibrillation (AF), the most common type of arrhythmia. A more recent cause of cardioembolisms is Transcatheter Aortic Valve Replacements (TAVRs), which may onset post-procedural adverse events such as stroke and Silent Brain Infarcts (SBIs), for which no definitive treatment exists, and which will only get worse as TAVRs are implanted in younger and lower risk patients. It is well known that some specific characteristics of elderly patients may lower the safety and efficacy of anticoagulation therapy, making it a real urgency to find alternative therapies. We propose a device consisting of a strut structure placed at the base of the treated artery to model the potential risk of cerebral embolisms caused by dislodged debris of varying sizes. This work analyzes a design based on a patented medical device, intended to block cardioembolisms from entering the cerebrovascular system, with a particular focus on AF, and potentially TAVR patients. The study has been carried out in two stages. Both of them based on computational fluid dynamics (CFD) coupled with Lagrangian particle tracking method. The first stage of the work evaluates a variety of strut thicknesses and inter-strut spacings, contrasting with the device-free baseline geometry. The analysis is carried out by imposing flowrate waveforms characteristic of both healthy and AF patients. Boundary conditions are calibrated to reproduce physiological flowrates and pressures in a patient's aortic arch. In the second stage, the optimal geometric design from the first stage was employed, with the addition of lateral struts to prevent the filtration of particles and electronegatively charged strut surfaces, studying the effect of electrical forces on the clots if they are considered charged. Flowrate boundary conditions were used to emulate both healthy and AF conditions. Results from numerical simulations coming form the first stage indicate that the device blocks particles of sizes larger than the inter-strut spacing. It was found that lateral strut space had the highest impact on efficacy. Based on the results of the second stage, deploying the electronegatively charged device in all three aortic arch arteries, the number of particles entering these arteries was reduced on average by 62.6% and 51.2%, for the healthy and diseased models respectively, matching or surpassing current oral anticoagulant efficacy. In conclusion, the device demonstrated a two-fold mechanism for filtering emboli: while the smallest particles are deflected by electrostatic repulsion, avoiding microembolisms, which could lead to cognitive impairment, the largest ones are mechanically filtered since they cannot fit in between the struts, effectively blocking the full range of particle sizes analyzed in this study. The device presented in this manuscript offers an anticoagulant-free method to prevent stroke and SBIs, imperative given the growing population of AF and elderly patients., This research has been supported by “ELEM biotech - the virtual human factory” (www.elem.bio), an INPhINIT fellowship from “la Caixa” Foundation (fellowship ID: LCF/BQ/DI18/11660044), by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No. 713673., by the project CompBioMed2 (H2020-EU.1.4.1.3. Grant No. 823712), by CREXDATA project (HORIZON-CL4-2022-DATA-01. Grant No. 101092749) and by Torres Quevedo Program (PTQ2018-010290), Ministerio de Ciencia e Innovacion, Spain. ELEM Biotech was not involved in the study design, analysis, interpretation of data, the writing of this article or the decision to submit it for publication., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

TorchMD: a deep learning framework for molecular simulations

  • Doerr, Stefan, 1987-
  • Majewski, Maciej
  • Pérez, Adrià
  • Krämer, Andreas
  • Clementi, Cecilia
  • Noé, Frank
  • Giorgino, Toni
  • De Fabritiis, Gianni
Molecular dynamics simulations provide a mechanistic description of molecules by relying on empirical potentials. The quality and transferability of such potentials can be improved leveraging data-driven models derived with machine learning approaches. Here, we present TorchMD, a framework for molecular simulations with mixed classical and machine learning potentials. All force computations including bond, angle, dihedral, Lennard-Jones, and Coulomb interactions are expressed as PyTorch arrays and operations. Moreover, TorchMD enables learning and simulating neural network potentials. We validate it using standard Amber all-atom simulations, learning an ab initio potential, performing an end-to-end training, and finally learning and simulating a coarse-grained model for protein folding. We believe that TorchMD provides a useful tool set to support molecular simulations of machine learning potentials. Code and data are freely available at github.com/torchmd., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 823712 (CompBioMed2 Project).