Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Geometric, Biomechanic and Haemodynamic Aortic Abnormalities Assessed by 4D Flow Cardiovascular Magnetic Resonance in Patients Treated by TEVAR Following Blunt Traumatic Thoracic Aortic Injury

  • Gil-Sala, Daniel|||0000-0003-4885-5836
  • Guala, Andrea|||0000-0002-5006-8164
  • Garcia Reyes, Marvin
  • Azancot, María A.|||0000-0002-8447-1373
  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Allegue Allegue, Nicolas
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Goncalves Martins, Gabriela
  • Ruiz Muñoz, Aroa|||0000-0002-1138-8528
  • Constenla Garcia, Ivan|||0000-0002-7107-2277
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
  • Tello Díaz, Cristina
  • Ferreira-Gonzalez, Ignacio|||0000-0002-1208-5561
  • Rodríguez Palomares, José F.|||0000-0002-7229-9780
  • Bellmunt Montoya, Sergi|||0000-0002-2851-720X
Objective: Thoracic endovascular aortic repair (TEVAR) is widely used for the treatment of patients with blunt traumatic thoracic aortic injury (BTAI). However, aortic haemodynamic and biomechanical implications of this intervention are poorly investigated. This study aimed to assess whether patients treated by TEVAR following BTAI have thoracic aortic abnormalities in geometry, stiffness, and haemodynamics. Methods: Patients with BTAI treated by TEVAR at Vall d'Hebron Hospital between 1999 and 2019 were compared with propensity score matched healthy volunteers (HVs). All subjects underwent cardiovascular magnetic resonance (CMR) comprising a 4D flow CMR sequence. Spatially resolved aortic diameter, length, volume, and curvature were assessed. Pulse wave velocity, distensibility, and longitudinal strain (all measurements of aortic stiffness) were determined regionally. Moreover, advanced haemodynamic descriptors were quantified: systolic flow reversal ratio (SFRR), quantifying backward flow during systole, and in plane rotational flow (IRF), measuring in plane strength of helical flow. Results: Twenty-six BTAI patients treated by TEVAR were included and matched with 26 HVs. They did not differ in terms of age, sex, and body surface area. Patients with TEVAR had a larger and longer ascending aorta (AAo) and marked abnormalities in local curvature. Aortic stiffness was greater in the aortic segments proximal and distal to TEVAR compared with controls. Moreover, TEVAR patients presented strongly altered flow dynamics compared with controls: a reduced IRF from the distal AAo to the proximal descending aorta and an increased SFRR in the whole thoracic aorta. These differences persisted adjusting for cardiovascular risk factors and were independent of time elapsed since TEVAR implantation. Conclusion: At long term follow up, previously healthy patients who underwent TEVAR implantation following BTAI had increased diameter, length and volume of the ascending aorta, and increased aortic stiffness and abnormal flow patterns in the whole thoracic aorta compared with matched controls. Further studies should address whether these alterations have clinical implications.
DAU Arxiu Digital de la Universitat Ramon Llull
Publicación Artículo científico (JournalArticle)

Fluid-structure interaction simulations outperform computational fluid dynamics in the description of thoracic aorta haemodynamics and in the differentiation of progressive dilation in Marfan syndrome patients

  • Martorell López, Jordi
  • Molins, Jose Javier
  • Pons, R.
  • Guala, A.
  • Rodríguez-Palomares, J.F.
  • Cajas, J.C.
  • Dux-Santoy, L.
  • Teixidó-Tura, G.
  • Vázquez, M.
  • Evangelista, A.
Abnormal fluid dynamics at the ascending aorta may be at the origin of aortic aneurysms. This study was aimed at comparing the performance of computational fluid dynamics (CFD) and fluid–structure interaction (FSI) simulations against four-dimensional (4D) flow magnetic resonance imaging (MRI) data; and to assess the capacity of advanced fluid dynamics markers to stratify aneurysm progression risk. Eight Marfan syndrome (MFS) patients, four with stable and four with dilating aneurysms of the proximal aorta, and four healthy controls were studied. FSI and CFD simulations were performed with MRI-derived geometry, inlet velocity field and Young's modulus. Flow displacement, jet angle and maximum velocity evaluated from FSI and CFD simulations were compared to 4D flow MRI data. A dimensionless parameter, the shear stress ratio (SSR), was evaluated from FSI and CFD simulations and assessed as potential correlate of aneurysm progression. FSI simulations successfully matched MRI data regarding descending to ascending aorta flow rates (R2 = 0.92) and pulse wave velocity (R2 = 0.99). Compared to CFD, FSI simulations showed significantly lower percentage errors in ascending and descending aorta in flow displacement (−46% ascending, −41% descending), jet angle (−28% ascending, −50% descending) and maximum velocity (−37% ascending, −34% descending) with respect to 4D flow MRI. FSI- but not CFD-derived SSR differentiated between stable and dilating MFS patients. Fluid dynamic simulations of the thoracic aorta require fluid–solid interaction to properly reproduce complex haemodynamics. FSI- but not CFD-derived SSR could help stratifying MFS patients.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Fluid-structure interaction simulations outperform computational fluid dynamics in the description of thoracic aorta haemodynamics and in the differentiation of progressive dilation in Marfan syndrome patients

  • Martorell López, Jordi
  • Molins, Jose Javier
  • Pons, R.
  • Guala, A.
  • Rodríguez-Palomares, J.F.
  • Cajas, J.C.
  • Dux-Santoy, L.
  • Teixidó-Tura, G.
  • Vázquez, M.
  • Evangelista, A.
Abnormal fluid dynamics at the ascending aorta may be at the origin of aortic aneurysms. This study was aimed at comparing the performance of computational fluid dynamics (CFD) and fluid–structure interaction (FSI) simulations against four-dimensional (4D) flow magnetic resonance imaging (MRI) data; and to assess the capacity of advanced fluid dynamics markers to stratify aneurysm progression risk. Eight Marfan syndrome (MFS) patients, four with stable and four with dilating aneurysms of the proximal aorta, and four healthy controls were studied. FSI and CFD simulations were performed with MRI-derived geometry, inlet velocity field and Young's modulus. Flow displacement, jet angle and maximum velocity evaluated from FSI and CFD simulations were compared to 4D flow MRI data. A dimensionless parameter, the shear stress ratio (SSR), was evaluated from FSI and CFD simulations and assessed as potential correlate of aneurysm progression. FSI simulations successfully matched MRI data regarding descending to ascending aorta flow rates (R2 = 0.92) and pulse wave velocity (R2 = 0.99). Compared to CFD, FSI simulations showed significantly lower percentage errors in ascending and descending aorta in flow displacement (−46% ascending, −41% descending), jet angle (−28% ascending, −50% descending) and maximum velocity (−37% ascending, −34% descending) with respect to 4D flow MRI. FSI- but not CFD-derived SSR differentiated between stable and dilating MFS patients. Fluid dynamic simulations of the thoracic aorta require fluid–solid interaction to properly reproduce complex haemodynamics. FSI- but not CFD-derived SSR could help stratifying MFS patients.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease

  • Rodríguez-Palomares, José Fernando
  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Guala, Andrea|||0000-0002-5006-8164
  • Kale, Raquel
  • Maldonado, Giuliana
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Galian-Gay, Laura|||0000-0001-6828-5928
  • Huguet, Marina
  • Valente, Filipa|||0000-0002-5569-3292
  • Gutiérrez García-Moreno, Laura
  • González-Alujas, Teresa
  • Johnson, Kevin M.
  • Wieben, Oliver
  • García-Dorado, David|||0000-0002-1126-1279
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
In patients with bicuspid valve (BAV), ascending aorta (AAo) dilatation may be caused by altered flow patterns and wall shear stress (WSS). These differences may explain different aortic dilatation morphotypes. Using 4D-flow cardiovascular magnetic resonance (CMR), we aimed to analyze differences in flow patterns and regional axial and circumferential WSS maps between BAV phenotypes and their correlation with ascending aorta dilatation morphotype. One hundred and one BAV patients (aortic diameter ≤ 45 mm, no severe valvular disease) and 20 healthy subjects were studied by 4D-flow CMR. Peak velocity, flow jet angle, flow displacement, in-plane rotational flow (IRF) and systolic flow reversal ratio (SFRR) were assessed at different levels of the AAo. Peak-systolic axial and circumferential regional WSS maps were also estimated. Unadjusted and multivariable adjusted linear regression analyses were used to identify independent correlates of aortic root or ascending dilatation. Age, sex, valve morphotype, body surface area, flow derived variables and WSS components were included in the multivariable models. The AAo was non-dilated in 24 BAV patients and dilated in 77 (root morphotype in 11 and ascending in 66). BAV phenotype was right-left (RL-) in 78 patients and right-non-coronary (RN-) in 23. Both BAV phenotypes presented different outflow jet direction and velocity profiles that matched the location of maximum systolic axial WSS. RL-BAV velocity profiles and maximum axial WSS were homogeneously distributed right-anteriorly, however, RN-BAV showed higher variable profiles with a main proximal-posterior distribution shifting anteriorly at mid-distal AAo. Compared to controls, BAV patients presented similar WSS magnitude at proximal, mid and distal AAo (p = 0.764, 0.516 and 0.053, respectively) but lower axial and higher circumferential WSS components (p < 0.001 for both, at all aortic levels). Among BAV patients, RN-BAV presented higher IRF at all levels (p = 0.024 proximal, 0.046 mid and 0.002 distal AAo) and higher circumferential WSS at mid and distal AAo (p = 0.038 and 0.046, respectively) than RL-BAV. However, axial WSS was higher in RL-BAV compared to RN-BAV at proximal and mid AAo (p = 0.046, 0.019, respectively). Displacement and axial WSS were independently associated with the root-morphotype, and circumferential WSS and SFRR with the ascending-morphotype. Different BAV-phenotypes present different flow patterns with an anterior distribution in RL-BAV, whereas, RN-BAV patients present a predominant posterior outflow jet at the sinotubular junction that shifts to anterior or right anterior in mid and distal AAo. Thus, RL-BAV patients present a higher axial WSS at the aortic root while RN-BAV present a higher circumferential WSS in mid and distal AAo. These results may explain different AAo dilatation morphotypes in the BAV population. The online version of this article (10.1186/s12968-018-0451-1) contains supplementary material, which is available to authorized users.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Decreased rotational flow and circumferential wall shear stress as early markers of descending aorta dilation in Marfan syndrome, a 4D flow CMR study

  • Guala, Andrea|||0000-0002-5006-8164
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Granato, C.
  • Ruiz Muñoz, Aroa|||0000-0002-1138-8528
  • Valente, Filipa|||0000-0002-5569-3292
  • Galian-Gay, Laura|||0000-0001-6828-5928
  • Gutiérrez García-Moreno, Laura
  • González-Alujas, Teresa
  • Johnson, K. M.
  • Wieben, Oliver
  • Sao-Avilés, Augusto|||0000-0001-8497-0909
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
  • Rodriguez-Palomares, J.
Diseases of the descending aorta have emerged as a clinical issue in Marfan syndrome following improvements in proximal aorta surgical treatment and the consequent increase in life expectancy. Although a role for hemodynamic alterations in the etiology of descending aorta disease in Marfan patients has been suggested, whether flow characteristics may be useful as early markers remains to be determined. Seventy-five Marfan patients and 48 healthy subjects were prospectively enrolled. In- and through-plane vortexes were computed by 4D flow cardiovascular magnetic resonance (CMR) in the thoracic aorta through the quantification of in-plane rotational flow and systolic flow reversal ratio, respectively. Regional pulse wave velocity and axial and circumferential wall shear stress maps were also computed. In-plane rotational flow and circumferential wall shear stress were reduced in Marfan patients in the distal ascending aorta and in proximal descending aorta, even in the 20 patients free of aortic dilation. Multivariate analysis showed reduced in-plane rotational flow to be independently related to descending aorta pulse wave velocity. Conversely, systolic flow reversal ratio and axial wall shear stress were altered in unselected Marfan patients but not in the subgroup without dilation. In multivariate regression analysis proximal descending aorta axial (p = 0.014) and circumferential (p = 0.034) wall shear stress were independently related to local diameter. Reduced rotational flow is present in the aorta of Marfan patients even in the absence of dilation, is related to aortic stiffness and drives abnormal circumferential wall shear stress. Axial and circumferential wall shear stress are independently related to proximal descending aorta dilation beyond clinical factors. In-plane rotational flow and circumferential wall shear stress may be considered as an early marker of descending aorta dilation in Marfan patients. The online version of this article (10.1186/s12968-019-0572-1) contains supplementary material, which is available to authorized users.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Low and Oscillatory Wall Shear Stress Is Not Related to Aortic Dilation in Patients With Bicuspid Aortic Valve

  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Guala, Andrea|||0000-0002-5006-8164
  • Sotelo, Julio
  • Uribe, Sergio
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Ruiz Muñoz, Aroa|||0000-0002-1138-8528
  • Hurtado, Daniel E.
  • Valente, Filipa|||0000-0002-5569-3292
  • Galian-Gay, Laura|||0000-0001-6828-5928
  • Gutiérrez García-Moreno, Laura
  • González-Alujas, Teresa
  • Johnson, Kevin M.
  • Wieben, Oliver
  • Ferreira-Gonzalez, Ignacio|||0000-0002-1208-5561
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
  • Rodríguez Palomares, José F.|||0000-0002-7229-9780
Supplemental Digital Content is available in the text. To assess the relationship between regional wall shear stress (WSS) and oscillatory shear index (OSI) and aortic dilation in patients with bicuspid aortic valve (BAV). Forty-six consecutive patients with BAV (63% with right-left-coronary-cusp fusion, aortic diameter ≤ 45 mm and no severe valvular disease) and 44 healthy volunteers were studied by time-resolved 3-dimensional phase-contrast magnetic resonance imaging. WSS and OSI were quantified at different levels of the ascending aorta and the aortic arch, and regional WSS and OSI maps were obtained. Seventy percent of BAV had ascending aorta dilation. Compared with healthy volunteers, patients with BAV had increased WSS and decreased OSI in most of the ascending aorta and the aortic arch. In both BAV and healthy volunteers, regions of high WSS matched regions of low OSI and vice versa. No regions of both low WSS and high OSI were identified in BAV compared with healthy volunteers. Patients with BAV with dilated compared with nondilated aorta presented low and oscillatory WSS in the aortic arch, but not in the ascending aorta where dilation is more prevalent. Furthermore, no regions of concomitant low WSS and high OSI were identified when BAV were compared according to leaflet fusion pattern, despite the well-known differences in regional dilation prevalence. Regions with low WSS and high OSI do not match those with the highest prevalence of dilation in patients with BAV, thus providing no evidence to support the low and oscillatory shear stress theory in the pathogenesis of proximal aorta dilation in the presence of BAV.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Fluid-structure interaction simulations outperform computational fluid dynamics in the description of thoracic aorta haemodynamics and in the differentiation of progressive dilation in Marfan syndrome patients

  • Pons, Ramon|||0000-0003-4273-9084
  • Guala, Andrea|||0000-0002-5006-8164
  • Rodríguez-Palomares, J. F.
  • Cajas, J. C.
  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Molins, J. J.
  • Vázquez, Mariano|||0000-0002-2526-6708
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
  • Martorell, Jordi|||0000-0002-2043-2762
Abnormal fluid dynamics at the ascending aorta may be at the origin of aortic aneurysms. This study was aimed at comparing the performance of computational fluid dynamics (CFD) and fluid-structure interaction (FSI) simulations against four-dimensional (4D) flow magnetic resonance imaging (MRI) data; and to assess the capacity of advanced fluid dynamics markers to stratify aneurysm progression risk. Eight Marfan syndrome (MFS) patients, four with stable and four with dilating aneurysms of the proximal aorta, and four healthy controls were studied. FSI and CFD simulations were performed with MRI-derived geometry, inlet velocity field and Young's modulus. Flow displacement, jet angle and maximum velocity evaluated from FSI and CFD simulations were compared to 4D flow MRI data. A dimensionless parameter, the shear stress ratio (SSR), was evaluated from FSI and CFD simulations and assessed as potential correlate of aneurysm progression. FSI simulations successfully matched MRI data regarding descending to ascending aorta flow rates (R 2 = 0.92) and pulse wave velocity (R 2 = 0.99). Compared to CFD, FSI simulations showed significantly lower percentage errors in ascending and descending aorta in flow displacement (-46% ascending, -41% descending), jet angle (-28% ascending, -50% descending) and maximum velocity (-37% ascending, -34% descending) with respect to 4D flow MRI. FSI- but not CFD-derived SSR differentiated between stable and dilating MFS patients. Fluid dynamic simulations of the thoracic aorta require fluid-solid interaction to properly reproduce complex haemodynamics. FSI- but not CFD-derived SSR could help stratifying MFS patients