Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Unsupervised clustering of songle-lead ECGs associates with prevalent and incident heart failure in coronary artery disease

  • Madrid, Josseline
  • Young, William
  • van Duijvenboden, Stefan
  • Orini, Michele
  • Munroe, Patricia
  • Ramírez García, Julia*
  • Mincholé, Ana
Clinical consequences of coronary artery disease (CAD) are varied [e.g. atrial fibrillation (AF) and heart failure (HF)], and current risk stratification tools are ineffective. We aimed to identify clusters of individuals with CAD exhibiting unique pat-terns on the electrocardiogram (ECG) in an unsupervised manner and assess their association with cardiovascular risk. Methods and results Twenty-one ECG markers were derived from single-lead median-beat ECGs of 1928 individuals with CAD without a previous diagnosis of AF, HF, or ventricular arrhythmia (VA) from the imaging study in UK Biobank (CAD-IMG-UKB). An un-supervised clustering algorithm was used to group these markers into distinct clusters. We characterized each cluster according to their demographic and ECG characteristics, as well as their prevalent and incident risk of AF, HF, and VA(4-year median follow-up). Validation and association with prevalent diagnoses were performed in an independent cohort of 1644 individuals. The model identified two clusters within the CAD-IMG-UKB cohort. Cluster 1 (n = 359) exhibited pro-longed QRS duration and QT intervals, along with greater morphological variations in QRS and T-waves, compared with Cluster 2 (n = 1569). Cluster 1, relative to Cluster 2, had a significantly higher risk of incident HF [hazard ratio (HR):2.40, 95% confidence interval (CI): 1.51–3.83], confirmed by independent validation (HR: 1.77, CI: 1.31–2.41). It also showed a higher association with prevalent HF (odds ratio: 4.10, CI: 2.02–8.29), independent of clinical risk factors. Conclusion Our approach identified a cluster of individuals with CAD sharing ECG characteristics indicating HF risk, holding significant implications for targeted treatment and prevention enabling accessible large-scale screening.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG-based evaluation of ventricular synchrony in left bundle branch area pacing through characterization of the activation sequence

  • Sales-Belles, Clara
  • Mincholé, Ana
  • Melero-Polo, Jorge
  • Cabrera-Ramos, Mercedes
  • Vadillo-Martín, Pablo
  • Montilla-Padilla, Isabel
  • Sorinas-Villanueva, Laura
  • Julián-García, Inés
  • Mayo-Carlos, Gualber Vitto
  • Ruiz-Arroyo, José Ramón
  • Pueyo, Esther
  • Ramos-Maqueda, Javier
Left bundle branch area pacing (LBBAP) overcomes ventricular dyssynchrony induced by conventional right ventricular pacing (RVP). Despite QRS duration (QRSd) being the standard ECG marker for biventricular synchrony, it lacks insights into the ventricular activation sequence. Our aim is to assess biventricular synchrony by characterizing the ventricular activation sequence and introducing robust markers using the 12-lead ECG. A prospective single-center study was conducted, involving patients with pacemaker indication due to bradycardia. Patients were divided into LBBAP and RVP, and classified by baseline-QRS morphology. To assess biventricular synchrony, low frequency-based QRS analysis was performed to compute the ventricular activation sequence and precordial activation delay (pAD). Additional QRS markers including QRSd, QRS60, and QRS area (QRSa) were calculated. A total of 176 patients (107 LBBAP, 69 RVP) were included. The paced ventricular activation sequence indicated a more physiological pattern after LBBAP than RVP, with lower pAD values in narrow QRS, RBBB, and LBBB subgroups [ − 10( − 20,14) vs. 26(5, 39) ms;  − 18( − 30,  − 8) vs. 34(26, 55) ms; 10( − 14, 25) vs. 32(12, 48) ms] (p < 0.01). In all subgroups, QRS60 showed lower values after LBBAP than RVP [52(41, 62) vs.73(65, 80) ms; 60(55, 66) vs. 77(67, 83) ms; 59(53, 64) vs. 77(74, 82) ms] (p < 0.01) and QRSa were also lower [53(38, 66) vs. 121(92, 143) μVs; 60(50, 89) vs. 124(97, 159) μVs; 62(52, 80) vs. 133(99, 148) μVs] (p < 0.01). pAD provides valuable insights into ventricular activation beyond paced-QRSd. Together with QRS60 and QRSa, pAD could be a promising tool to assess biventricular synchrony.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Electrophysiological characterization of pre‐adolescents born with intrauterine growth restriction: insights from clinical and computational data

  • Bueno-Palomeque, Freddy L.
  • Zacur, Ernesto
  • Pueyo, Esther
  • Crispi, Fàtima
  • Laguna, Pablo
  • Mincholé, Ana
Anatomical changes associated with intra-uterine growth restriction (IUGR) have been observed in different age groups and linked to cardiovascular complications. This study analysed the electrocardiogram (ECG) in pre-adolescents with severe IUGR, comparing QRS complex and T-wave biomarkers with controls. Computer simulations explored links between anatomical re-modelling and ECG biomarkers, providing insights into the potential cardiovascular risk associated with IUGR-induced re-modelling. Clinical recordings were analysed using principal component analysis (PCA) to compute spatially transformed leads, enhancing QRS complex and T-wave delineation for depolarization and repolarization assessment. Transformed leads analysis revealed a 4-ms increase in QRS complex duration (QRS ) and a 2-ms increase in the T peak-to-end interval (T ) in IUGR subjects compared to controls. We conducted electrophysiological in silico simulations using anatomical models based on clinical IUGR data. These models, derived from a reference control, incorporated key geometric changes associated with IUGR, the apex-base length, basal diameter, wall thickness () and ventricular tissue volume, to assess their impact on depolarization and repolarization intervals. In silico PCA leads showed increased QRS , QRS amplitude and T in globular models, consistent with clinical data. Despite the QRS increase, the QT interval increases but is not linearly related to the change. These findings suggest that cardiac re-modelling primarily influences the depolarization cycle, notably QRS , while repolarization intervals increase but are not directly related to the increase. The study highlights the impact of geometric and volumetric changes in IUGR-related cardiac re-modelling, also emphasizing the need for further research on electrophysiological re-modelling and its effects on cardiac function.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Integrated multi-modal data analysis for computational modeling of healthy and location-dependent myocardial infarction conditions in porcine hearts

  • Rosales, Ricardo M.
  • Wu, Ming
  • Claus, Piet
  • Janssens, Stefan
  • Ríos-Muñoz, Gonzalo R.
  • Fernández-Santos, María Eugenia
  • Martínez-Legazpi, Pablo
  • Bermejo, Javier
  • Flanagan, Aiden
  • Doblaré, Manuel
  • Mincholé, Ana
  • Pueyo, Esther
Porcine hearts are widely used for preclinical cardiac evaluation. Computational models, by effectively integrating comprehensive experimental data, often reinforce this preclinical assessment. Using extensive multi-modal data, we developed swine ventricular digital twins for healthy and chronic myocardial infarction (MI) conditions to investigate the roles of the cardiac conduction system (CS), spatial repolarization heterogeneities, cardiomyocyte orientation, cell-to-cell coupling, and MI characteristics on ventricular function. We analyzed cardiac magnetic resonance (CMR) images, electrocardiograms (ECGs), and optical (OM) and electroanatomical mapping from 5 healthy and 10 MI pigs. CS architectures were built from OM and ECG recordings. Myocardial fiber orientation, action potential characteristics, and cell-to-cell conductivity in MI tissue were defined from OM and CMR data. Simulated ECGs for healthy and MI models of left anterior descending and left circumflex occlusions were compared to experimental ECGs and were used to assess MI-induced changes. Subject-specific fiber orientation calibration minimally affected electrophysiology, with conduction velocity (CV) and action potential duration (APD) changing by less than 3.6% with respect to standard orientation. Accurate CS and repolarization heterogeneities reproduced depolarization (Pearson correlation 0.76 for QRS) and repolarization (Pearson correlation 0.74 for T-wave) patterns. Incorporating experimentally guided MI-induced alterations enabled the replication of MI depolarization and repolarization features (relative errors: 0.5% CV, 2.9% APD), yielded realistic T-wave morphologies (0.63 Pearson correlation), and revealed ECG patterns specific to vessel-dependent occlusions. Thus, by integrating extensive multi-modal data, we advance porcine cardiac digital twins and demonstrate the influence of key structural and electrophysiological parameters on healthy and MI heart function, providing a robust computational framework for mechanistic and translational applications.