Pasar al contenido principal

PROCESADO DE SEÑAL GUIADO POR LA FISIOLOGIA PARA MONITORIZACION AMBULATORIA DE LA DEPRESION

RTI2018-097723-B-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 41
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Baroreflex sensitivity measured by pulse photoplethysmography

  • Lázaro, Jesús
  • Gil, Eduardo
  • Orini, Michele
  • Laguna, Pablo
  • Bailón, Raquel
Novel methods for assessing baroreflex sensitivity (BRS) using only pulse photoplethysmography (PPG) signals are presented. Proposed methods were evaluated with a data set containing electrocardiogram (ECG), blood pressure (BP), and PPG signals from 17 healthy subjects during a tilt table test. The methods are based on a surrogate of a index, which is defined as the power ratio of RR interval variability (RRV) and that of systolic arterial pressure series variability (SAPV). The proposed a index surrogates use pulse-to-pulse interval series variability (PPV) as a surrogate of RRV, and different morphological features of the PPG pulse which have been hypothesized to be related to BP, as series surrogates of SAPV. A time-frequency technique was used to assess BRS, taking into account the non-stationarity of the protocol. This technique identifies two time-varying frequency bands where RRV and SAPV (or their surrogates) are expected to be coupled: the low frequency (LF, inside 0.04–0.15 Hz range), and the high frequency (HF, inside 0.15–0.4 Hz range) bands. Furthermore, time-frequency coherence is used to identify the time intervals when the RRV and SAPV (or their surrogates) are coupled. Conventional a index based on RRV and SAPV was used as Gold Standard. Spearman correlation coefficients between conventional a index and its PPG-based surrogates were computed and the paired Wilcoxon statistical test was applied in order to assess whether the indices can find significant differences (p < 0.05) between different stages of the protocol. The highest correlations with the conventional a index were obtained by the a-index-surrogate based on PPV and pulse up-slope (PUS), with 0.74 for LF band, and 0.81 for HF band. Furthermore, this index found significant differences between rest stages and tilt stage in both LF and HF bands according to the paired Wilcoxon test, as the conventional a index also did. These results suggest that BRS changes induced by the tilt test can be assessed with high correlation by only a PPG signal using PPV as RRV surrogate, and PPG morphological features as SAPV surrogates, being PUS the most convenient SAPV surrogate among the studied ones.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Electrocardiogram-derived tidal volume during treadmill stress test

  • Milagro, Javier
  • Hernando, David
  • Lázaro, Jesús
  • Casajús, Jose Antonio
  • Garatachea, Nuria
  • Gil, Eduardo
  • Bailón, Raquel
Objective: Electrocardiogram (ECG) has been regarded as a source of respiratory information with the main focus in the estimation of the respiratory rate. Although little research concerning the estimation of tidal volume (TV) has been conducted, there are several ECG-derived features that have been related with TV in the literature, such as ECG-derived respiration, heart rate variability or respiratory rate. In this work, we exploited these features for estimating TV using a linear model. Methods: 25 young (33.4 ± 5.2 years) healthy male volunteers were recruited for performing a maximal (MaxT) and a submaximal (SubT) treadmill stress test, which were conducted in different days. Both tests were automatically segmented in stages attending to the heart rate. Afterwards, a subject-specific TV model was calibrated for each stage, employing features from MaxT, and the model was later used for estimating the TV in SubT. Results: During exercise, the different proposed approaches led to relative fitting errors lower than 14% in most of the cases and than 6% in some of them. Conclusion: Low achieved fitting errors suggest that TV can be estimated from ECG during a treadmill stress test. Significance: The results suggest that it is possible to estimate TV during exercise using only ECG-derived features.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG-derived respiratory rate in atrial fibrillation

  • Kontaxis, Spyridon
  • Lázaro Plaza, Jesús
  • Corino, Valentina
  • Sandberg, Frida
  • Bailón Luesma, Raquel
  • Laguna Lasaosa, Pablo
  • Sörnmo, Leif
Objective: The present study addresses the problem of estimating the respiratory rate from the morphological ECG variations in the presence of atrial fibrillatory waves (f-waves). The significance of performing f-wave suppression before respiratory rate estimation is investigated. Methods: The performance of a novel approach to ECG-derived respiration, named “slope range” (SR) and designed particularly for operation in atrial fibrillation (AF), is compared to that of two well-known methods based on either R-wave angle (RA) or QRS loop rotation angle (LA). A novel rule is proposed for spectral peak selection in respiratory rate estimation. The suppression of f-waves is accomplished using signal- and noise-dependent QRS weighted averaging. The performance evaluation embraces real as well as simulated ECG signals acquired from patients with persistent AF; the estimation error of the respiratory rate is determined for both types of signals. Results: Using real ECG signals and reference respiratory signals, rate estimation without f-wave suppression resulted in a median error of 0.015±0.021 Hz and 0.019±0.025 Hz for SR and RA, respectively, whereas LA with f-wave suppression resulted in 0.034±0.039 Hz. Using simulated signals, the results also demonstrate that f-wave suppression is superfluous for SR and RA, whereas it is essential for LA. Conclusion: The results show that SR offers the best performance as well as computational simplicity since f-wave suppression is not needed. Significance: The respiratory rate can be robustly estimated from the ECG in the presence of AF.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Finger and forehead PPG signal comparison for respiratory rate estimation

  • Hernando, Alberto
  • Peláez-Coca, María Dolores
  • Lozano, María Teresa
  • Lázaro, Jesús
  • Gil, Eduardo
Objective: an evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. Approach: finger-PPG, forehead-PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability (PWV), pulse amplitude variability (PAV) and the respiratory- induced intensity variability (RIIV). Respiratory rate was estimated from each one of the 4 PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. Main results: results show a better performance in terms of successful estimation and relative error when: i) PPG signal is recorded in the finger; ii) the respiratory rate is less than 0.4 Hz; iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. Significance: these results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that finger is better than forehead to estimate respiratory rate.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Monitoring breathing rate by fusing the physiological impact of respiration on video-photoplethysmogram with head movements

  • Iozzia, Luca
  • Lázaro, Jesús
  • Cerina, Luca
  • Silvestri, Davide
  • Mainardi, Luca
  • Laguna, Pablo
  • Gil, Eduardo
Objective: The simple observation of breathing rate (BR) remains the first and often the most sensitive marker of acute respiratory dysfunction. In fact, there are evidences that drastic changes in BR are a predictive indicator of adverse events (i.e. cardiac arrest). The aim of this study is to develop a camera-based technology that may provide near-continuously estimation of BR considering the effect of respiration on videoPPG (vPPG). &#13; Approach: The technology has been tested in two different experimental settings, including controlled BR and more challenging scenarios with spontaneous breathing pattern. Video data were processed offline to derive the vPPG signal. The method derives respiration from beat-to-beat PPG rate and morphology changes in amplitude and width driven by the physiological relationships between vPPG and respiration. Moreover, respiratory-induced head movements were used as additional source of information for the vPPG system. A combination of these methods has been exploited to estimate the respiratory rate every 10 second. &#13; Main Results: According to the results, respiratory frequencies in the central range (0.2-0.4 Hz) may be estimated using vPPG system with low relative error, eR < 2 % and interquartile range of order IQR < 5 %. However, the vPPG system showed a drop in performance at respiratory range boundaries, around 0.1 Hz and 0.5 Hz.&#13; Significance: This camera-based technology can be used as ubiquitous BR monitoring system. However, vPPG-based systems should consider the effect of the BR in the estimation, mainly in applications where respiratory rate is out of the range 0.2-0.4 Hz.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The Effect of Emotional Valence on Ventricular Repolarization Dynamics Is Mediated by Heart Rate Variability: A Study of QT Variability and Music-Induced Emotions

  • Orini, Michele
  • Al-Amodi, Faez
  • Koelsch, Stefan
  • Bailón, Raquel
Background: Emotions can affect cardiac activity, but their impact on ventricular repolarization variability, an important parameter providing information about cardiac risk and autonomic nervous system activity, is unknown. The beat-to-beat variability of the QT interval (QTV) from the body surface ECG is a non-invasive marker of repolarization variability, which can be decomposed into QTV related to RR variability (QTVrRRV) and QTV unrelated to RRV (QTVuRRV), with the latter thought to be a marker of intrinsic repolarization variability. Aim: To determine the effect of emotional valence (pleasant and unpleasant) on repolarization variability in healthy volunteers by means of QTV analysis. Methods: 75 individuals (24.5 ± 3.2 years, 36 females) without a history of cardiovascular disease listened to music-excerpts that were either felt as pleasant (n = 6) or unpleasant (n = 6). Excerpts lasted about 90 s and were presented in a random order along with silent intervals (n = 6). QTV and RRV were derived from the ECG and the time-frequency spectrum of RRV, QTV, QTVuRRV and QTVrRRV as well as time-frequency coherence between QTV and RRV were estimated. Analysis was performed in low-frequency (LF), high frequency (HF) and total spectral bands. Results: The heart rate-corrected QTV showed a small but significant increase from silence (median 347/interquartile range 31 ms) to listening to music felt as unpleasant (351/30 ms) and pleasant (355/32 ms). The dynamic response of QTV to emotional valence showed a transient phase lasting about 20 s after the onset of each musical excerpt. QTV and RRV were highly correlated in both HF and LF (mean coherence ranging 0.76–0.85). QTV and QTVrRRV decreased during listening to music felt as pleasant and unpleasant with respect to silence and further decreased during listening to music felt as pleasant. QTVuRRV was small and not affected by emotional valence. Conclusion: Emotional valence, as evoked by music, has a small but significant effect on QTV and QTVrRRV, but not on QTVuRRV. This suggests that the interaction between emotional valence and ventricular repolarization variability is mediated by cycle length dynamics and not due to intrinsic repolarization variability.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A comparative study of ECG-derived respiration in ambulatory monitoring using the single-lead ECG

  • Varon, Carolina
  • Morales, John
  • Lázaro, Jesús
  • Orini, Michele
  • Deviaene, Margot
  • Kontaxis, Spyridon
  • Testelmans, Dries
  • Buyse, Bertien
  • Borzée, Pascal
  • Sörnmo, Leif
  • Laguna, Pablo
  • Gil, Eduardo
  • Bailón, Raquel
Cardiorespiratory monitoring is crucial for the diagnosis and management of multiple conditions such as stress and sleep disorders. Therefore, the development of ambulatory systems providing continuous, comfortable, and inexpensive means for monitoring represents an important research topic. Several techniques have been proposed in the literature to derive respiratory information from the ECG signal. Ten methods to compute single-lead ECG-derived respiration (EDR) were compared under multiple conditions, including different recording systems, baseline wander, normal and abnormal breathing patterns, changes in breathing rate, noise, and artifacts. Respiratory rates, wave morphology, and cardiorespiratory information were derived from the ECG and compared to those extracted from a reference respiratory signal. Three datasets were considered for analysis, involving a total 59 482 one-min, single-lead ECG segments recorded from 156 subjects. The results indicate that the methods based on QRS slopes outperform the other methods. This result is particularly interesting since simplicity is crucial for the development of ECG-based ambulatory systems.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Electrocardiogram derived respiratory rate using a wearable armband

  • Lázaro, Jesús
  • Reljin, Natasa
  • Bailón, Raquel
  • Gil, Eduardo
  • Noh, Yeonsik
  • Laguna, Pablo
  • Chon, Ki H.
A method for deriving respiratory rate from an armband, which records three-channel electrocardiogram (ECG) using three pairs of dry (no hydrogel) electrodes, is presented. The armband device is especially convenient for long-term (months-years) monitoring because it does not use obstructive leads nor hydrogels/adhesives, which cause skin irritation even after few days. An ECG-derived respiration (EDR) based on respiration-related modulation of QRS slopes and R-wave angle approach was used. Moreover, we modified the EDR algorithm to lower the computational cost. Respiratory rates were estimated with the armband-ECG and the reference plethysmography-based respiration signals from 15 subjects who underwent breathing experiment consisting of five stages of controlled breathing (at 0.1, 0.2, 0.3, 0.4, and 0.5 Hz) and one stage of spontaneous breathing. The respiratory rates from the armband obtained a relative error with respect to the reference (respiratory rate estimated from the plethysmography-based respiration signal) that was not higher than 2.26% in median nor interquartile range (IQR) for all stages of fixed and spontaneous breathing, and not higher than 3.57% in median nor IQR in the case when the low computational cost algorithm was applied. These results demonstrate that respiration-related modulation of the ECG morphology are also present in the armband ECG device. Furthermore, these results suggest that respiration-related modulation can be exploited by the EDR method based on QRS slopes and R-wave angles to obtain respiratory rate, which may have a wide range of applications including monitoring patients with chronic respiratory diseases, epileptic seizures detection, stress assessment, and sleep studies, among others.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic waveform analysis for autonomic reactivity assessment in depression

  • Kontaxis, Spyridon
  • Gil, Eduardo
  • Marozas, Vaidotas
  • Lázaro, Jesús
  • García, Esther
  • Posadas-de Miguel, Mar
  • Siddi, Sara
  • Bernal, María Luisa
  • Aguiló, Jordi
  • Haro, Josep María
  • de la Cámara, Concepción
  • Laguna, Pablo
  • Bailón, Raquel
Objective: In the present study, a photoplethysmographic (PPG) waveform analysis for assessing differences in autonomic reactivity to mental stress between patients with Major Depressive Disorder (MDD) and healthy control (HC) subjects is presented. Methods: PPG recordings of 40 MDD and 40 HC subjects were acquired at basal conditions, during the execution of cognitive tasks, and at the post-task relaxation period. PPG pulses are decomposed into three waves (a main wave and two reflected waves) using a pulse decomposition analysis. Pulse waveform characteristics such as the time delay between the position of the main wave and reflected waves, the percentage of amplitude loss in the reflected waves, and the heart rate (HR) are calculated among others. The intra-subject difference of a feature value between two conditions is used as an index of autonomic reactivity. Results: Statistically significant individual differences from stress to recovery were found for HR and the percentage of amplitude loss in the second reflected wave ( A13 ) in both HC and MDD group. However, autonomic reactivity indices related to A13 reached higher values in HC than in MDD subjects (Cohen's d =0.81, AUC = 0.74), implying that the stress response in depressed patients is reduced. A statistically significant (p < 0.001) negative correlation (r = 0.5) between depression severity scores and A13 was found. Conclusion: A decreased autonomic reactivity is associated with higher degree of depression. Significance: Stress response quantification by dynamic changes in PPG waveform morphology can be an aid for the diagnosis and monitoring of depression.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Heart Rate Variability and Exceptional Longevity

  • Hernández-Vicente, A.
  • Hernando, D.
  • Santos-Lozano, A.
  • Rodríguez-Romo, G.
  • Vicente-Rodríguez, G.
  • Pueyo, E.
  • Bailón, R.
  • Garatachea, N.
Centenarians are the paradigm of human extreme longevity and healthy aging, because they have postponed, if not avoided, mayor age-related diseases. The purpose of this study was to investigate potential differences in resting heart rate variability (HRV) between young adults, octogenarians, and centenarians and assess whether HRV variables are predictors of all-cause mortality in centenarians. To this end, three groups of participants: young adults (N = 20; 20.6 ± 2.3 years), octogenarians (N = 18; 84.1 ± 2.6 years), and centenarians (N = 17; 101.9 ± 1.9 years) were monitored for 15 min at rest (seated, without moving or talking) to measure RR intervals, from which HRV was evaluated. Our results showed a clear decrease with age in the main parasympathetic HRV variables, as well as in the standard deviation (SD) of the RR series [SD of normal-to-normal interval (SDNN)] and in low frequency (LF) heart rate (HR) oscillations, although differences between octogenarians and centenarians did not reach statistical significance. In 14 centenarians followed until death, only SDNN showed significant correlation (¿ = 0.536; p = 0.048) with survival prognosis. Additionally, SDNN <19 ms was associated with early mortality (=1 year) in centenarians (Hazard Ratio = 5.72). In conclusion, HRV indices reflecting parasympathetic outflow as well as SDNN and LF all present an age-related reduction, which could be representative of a natural exhaustion of allostatic systems related to age. Moreover, low SDNN values (<19 ms) could be associated with early mortality in centenarians. HRV seems to play a role in exceptional longevity, which could be accounted for by centenarians’ exposome.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmogram Signal Morphology-Based Stress Assessment

  • Rinkevicius, M.
  • Kontaxis, S.
  • Gil, E.
  • Bailon, R.
  • Lázaro, J.
  • Laguna, P.
  • Marozas, V.
Stress is a healthy natural response to a perceived or actual threat. However, when stress is persistent, it may decrease work productivity, increase the risk of diseases, and affect the quality of life. Stress is reflected in physiological variables, such as heart rate, blood pressure, and pulse wave velocity among others. A photoplethys-mogram (PPG) contains information related to pulse rate and blood pressure. This study analyses parameters derived from PPG signal morphology for mental stress assessment.A low-complexity algorithm is designed using bandpass filtered higher-order derivatives of the PPG signal for estimation of six morphological parameters: the forward pulse wave amplitude A1, the systole and diastole durations T1 and Td, the time delays of reflected waves T12 and T13 from the renal and iliac sites in the central arteries, and the pulse duration Tp. The parameters were investigated on a set of 18 healthy subjects by using a modified Trier Social Stress Test.The results show that the most sensitive PPG morphology parameters to mental stress are the amplitude of forward wave A1, the duration of diastole Td, the time delay of the reflected wave T13, and the pulse-to-pulse interval Tp.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of the Heart Rate Variability Representations on the Quantification of the Cardiorespiratory Interactions during Autonomic Nervous System Blockade

  • Morales, J.F.
  • Bolea, J.
  • Van Huffel, S.
  • Bailón, R.
  • Varon, C.
The Heart Rate Variability (HRV) is a noninvasive tool to evaluate the activity of the autonomic nervous system. To study the HRV, different mathematical representations can be used. The selection of a representation might have an effect on the evaluation of the mechanisms that modulate the Heart Rate (HR). One of these mechanisms is the Respiratory Sinus Arrhythmia (RSA), i.e. an increased HR during inhalation and a decreased HR during exhalation. Different methods exist to quantify the RSA. A common approach is to calculate the power in the High Frequency (HF, 0.15 - 0.4 Hz) band of the spectrum of the HRV representation. More recently proposed methods use the respiratory signals to estimate the strength of the RSA.This paper studies the effect of the HRV representations on the quantification of the RSA. To this end, an experiment is used in which the sympathetic and parasympathetic branches of the autonomic nervous system are selectively blocked. Three different HRV representations are considered. Afterwards, the strength of the RSA is estimated using three approaches, namely the spectral content in the HF band of the HRV representations, orthogonal subspace projections and a time-frequency representation.The results suggest that the selection of an HRV representation does not have a significant impact on the RSA estimates in a healthy population.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Quantification of Linear and Nonlinear Cardiorespiratory Interactions under Autonomic Nervous System Blockade

  • Varon, C.
  • Hendrikx, D.
  • Bolea, J.
  • Laguna, P.
  • Bailón, R.
This paper proposes a methodology to extract both linear and nonlinear respiratory influences from the heart rate variability (HRV), by decomposing the HRV into a respiratory and a residual component. This methodology is based on least-squares support vector machines (LS-SVM) formulated for nonlinear function estimation. From this decomposition, a better estimation of the respiratory sinus arrhythmia (RSA) and the sympathovagal balance (SB) can be achieved. These estimates are first analyzed during autonomic blockade and an orthostatic maneuver, and then compared against the classical HRV and a model that considers only linear interactions. Results are evaluated using surrogate data analysis and they indicate that the classical HRV and the linear model underestimate the cardiorespiratory interactions. Moreover, the linear and nonlinear interactions appear to be mediated by different control mechanisms. These findings will allow to better assess the ANS and to improve the understanding of the interactions within the cardiorespiratory system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Heart Rate Variability Analysis Assessment for Asthma Control Stratification

  • Milagro, J.
  • Soto, L.
  • Giner, J.
  • Varon, C.
  • Laguna, P.
  • Plaza, V.
  • Gil, E.
  • Bailón, R.
Autonomic nervous system (ANS) has been suggested to play a major role in the pathogenesis of asthma. This hypothesis has motivated large research, revealing a reduced modulation of the heart rate in subjects with uncontrolled asthma, when compared to asthmatics with controlled symptomatology. In this work, we assessed ANS activity through heart rate variability analysis in a group of asthmatics classified attending to the control of their symptoms. This information was later used for training a logistic regression classifier aiming at differentiating between the levels of control in asthmatic patients. The accuracy of the classifier improved when including ANS information (71.77%, versus 64.73% when only clinical parameters were considered), suggesting that ANS assessment could contribute to better non-invasive asthma monitoring.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Cardiovascular Changes Induced by Acute Emotional Stress Estimated from the Pulse Transit Time Difference

  • Armañac, P.
  • Kontaxis, P.
  • Lázaro, J.
  • Laguna, P.
  • Bailón, R.
  • Gil, E.
In the present work, the difference between arrival times of photoplethysmographic (PPG) pulses from two different sites of the arterial tree (PTTD) is calculated. As the PTTD is considered to be related with arterial pulse wave velocity, an evaluation of it''s usefulness to identify states of acute mental stress is performed. A subset of fourteen healthy volunteers undergoing a stress protocol was analysed and a statistical test was carried out to evaluate the validity of the proposed method. The results showed that the standard deviation of the PTTD had sufficient statistical capacity to discern between states of stress and relaxation. Furthermore, a generalised descending trend of the mean PTTD can be seen from relaxation to stress.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic Nervous System Response to Heat Stress Exposure by Means of Heart Rate Variability

  • Kontaxis, S.
  • Bailon, R.
  • Rapalis, A.
  • Brazaitis, M.
  • Cernych, M.
  • Lazaro, J.
  • Laguna, P.
  • Gil, E.
  • Marozas, V.
In this study, a heart rate variability (HRV) analysis guided by respiration is conducted to assess changes in autonomic nervous system (ANS) regulation during pronounced heat stress induced by repetitive exposures to dry sauna in 13 young healthy subjects. The spectral power at the low frequency (LF) band [0.04, 0.15] Hz and at the high frequency band centered around the mean respiratory rate, estimated from ECG-derived respiration signals, are studied. The mean heart rate (HR), the total power of HRV, and the normalized LF power are also analyzed.Results show that mean HR and normalized LF power increase significantly after basal stage, not only during the sauna sessions, but also at the intermediate short rest stages and recovery phase after 30 min. A significant reduction in the total power of HRV during all sauna sessions is observed, while an increased power in LF band is shown only during recovery which might be related to improved cardiac function (increased cardiac output and reduced peripheral vascular resistance) after heat exposure. Respiratory rate does not change significantly during the protocol but a negative trend at stress stages may indicate a reverse reaction against an over-activation of the sympathetic branch. In conclusion, exposure to heat stress shifts sympathovagal balance of ANS toward sympathetic dominance that increases HR and diminishes HRV.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiorespiratory Coupling in Asthmatic Children

  • Milagro, J.
  • Gracia, J.
  • Seppä, V.P.
  • Karjalainen, J.
  • Paassilta, M.
  • Orini, M.
  • Gil, E.
  • Bailón, R.
  • Viik, J.
The relationship between cardiac and respiratory autonomic control has been suggested to be altered in several respiratory disorders. However, and despite the increasing prevalence of asthma, there are not studies assessing the cardiorespiratory coupling (CRC) with respect to the asthmatic status. Since altered autonomic control has been suggested to play a major role in asthma, in this work overnight CRC was assessed in a group of 67 children who underwent a three-month inhaled corticosteroids treatment. After treatment completion, CRC was reduced (p < 0.005) in the subjects without or with a low risk of asthma, whereas it kept unchanged in those with a worse prognosis, suggesting that an altered interaction between cardiac and respiratory activity might be related with an increased risk of asthma.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Acute stress state classification based on electrodermal activity modeling

  • Greco, A.
  • Valenza, G.
  • Lázaro, J.
  • Garzón-Rey, J. M.
  • Aguiló, J.
  • De la Cámara, C.
  • Bailón, Raquel
  • Scilingo, Enzo Pascuale
Acute stress is a physiological condition that may induce several neural dysfunctions with a significant impact on life quality. Accordingly, it would be important to monitor stress in everyday life unobtrusively and inexpensively. In this paper, we presented a new methodological pipeline to recognize acute stress conditions using electrodermal activity (EDA) exclusively. Particularly, we combined a rigorous and robust model (cvxEDA) for EDA processing and decomposition, with an algorithm based on a support vector machine to classify the stress state at a single- subject level. Indeed, our method, based on a single sensor, is robust to noise, applies a rigorous phasic decomposition, and implements an unbiased multiclass classification. To this end, we analyzed the EDA of 65 volunteers subjected to different acute stress stimuli induced by a modified version of the Trier Social Stress Test. Our results show that stress is successfully detected with an average accuracy of 94.62%. Besides, we proposed a further 4-class pattern recognition system able to distinguish between non-stress condition and three different stressful stimuli achieving an average accuracy as high as 75.00%. These results, obtained under controlled conditions, are the first step towards applications in ecological scenarios.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Multivariable relationships between autonomic nervous system related indices in hyperbaric environments

  • Perez-Martinez, C.
  • Pelaez-Coca, M.D.
  • Hernando, A.
  • Gil, E.
  • Sanchez, C.
The main aim of this work is to model the relationships between parameters extracted from the heart rate variability (HRV) signal, which is derived from the electrocardiogram (ECG), at different stages of a simulated immersion in a hyperbaric chamber. The response of the Autonomic Nervous System is known to be affected by changes in atmospheric pressure, reflected in changes in the HRV signal. A dataset consisting of ECG signals from 17 subjects exposed to a controlled hyperbaric environment, simulating depths from 0 m to 40 m, was used. Both linear and nonlinear dependences of HRV parameters were analysed using linear regression and Mutual Information (entropy-based) techniques. Furthermore, relationships between parameters of the HRV signals, biophysical variables of the subjects, and atmospheric pressure changes were characterized by artificial neural networks. In particular, self-organizing maps (SOM) were trained for modelling and clustering all the data. In the mid-term, these models could be the basis to create predictive models of HRV parameters at high depths in order to increase the safety for divers by warning them if some abnormal body response could be expected just by processing the ECG signal at sea level before immersion.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic Waveform in Hyperbaric Environment

  • Pelaez Coca, M.D.
  • Hernando, A.
  • Sanchez, C.
  • Lozano Albalate, M.T.
  • Izquierdo, D.
  • Gil, E.
The objective of this work is the identification of significant variations of morphological parameters of the photoplethysmographic (PPG) signal when the subjects are exposed to an increase in atmospheric pressure. To achieve this goal, the PPG signal of 26 subjects, exposed to a hyperbaric environment whose pressure increases up to 5 atm, has been recorded. From this record, segments of 4 minutes have been processed at 1 atm, 3 atm and 5 atm, both in the descending (D) and ascending (A) periods of the immersion. In total, four states (3D, 5, 3A and 1A) normalized to the basal state (1D) have been considered. In these segments, six morphological parameters of the PPG signal were studied. The width, the amplitude, the widths of the anacrotic and catacrotic phases, and the upward and downward slopes of each PPG pulse were extracted. The results showed significant increases in the three parameters related to the pulse width. This increase is significant in the four states analysed for the anacrotic phase width. Furthermore, a significant decrease in the amplitude and in both slopes (in the states 1A) was observed. These results show that the PPG width responds rapidly to the increase in pressure, indicating an activation of the sympathetic system, while amplitude and pulse slopes are decreased when the subjects are exposed to the hyperbaric environment for a considerable period of time.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of yoga on pulse rate variability measured from a venous pressure waveform

  • Hernando, D.
  • Nardelli, M.
  • Hocking, K.
  • Lazaro, J.
  • Alvis, B.
  • Gil, E.
  • Scilingo, E.P.
  • Brophy, D.R.
  • Valenza, G.
  • Laguna, P.
  • Brophy, C.
  • Bailon, R.
The benefits of yoga have been studied in different fields, from chronic health conditions to mental disorders, showing that it can help to improve the overall health. In particular, it has been proven that yoga also improves the autonomic function. Heart rate variability (HRV) at rest is commonly used as a non-invasive measure of autonomic regulation of heart rate. Alternatively, pulse rate variability (PRV) has been proposed as a surrogate of HRV. VoluMetrix has developed a novel technology that captures venous waveforms via sensors on the volar aspect of the wrist, called NIVAband. This study aims to assess the effect of yoga in the autonomic nervous system by analyzing the PRV obtained from the NIVA signal. Temporal (statistics of the normal-to-normal intervals), spectral (power in low and high frequency bands) and nonlinear (lagged Poincaré Plot analysis) parameters are analyzed before and after a yoga session in 20 healthy volunteers. The PRV analysis shows an increase in parameters related to parasympathetic activity and overall variability, and a decrease in parameters related to sympathetic activity and mean heart rate. These results support the beneficial effect of yoga in autonomic nervous system, increasing the parasympathetic activity.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Validity of the polar h7 heart rate sensor for heart rate variability analysis during exercise in different age, body composition and fitness level groups

  • Hernández-Vicente, A.
  • Hernando, D.
  • Marín-Puyalto, J.
  • Vicente-Rodríguez, G.
  • Garatachea, N.
  • Pueyo, E.
  • Bailón, R.
This work aims to validate the Polar H7 heart rate (HR) sensor for heart rate variability (HRV) analysis at rest and during various exercise intensities in a cohort of male volunteers with different age, body composition and fitness level. Cluster analysis was carried out to evaluate how these phenotypic characteristics influenced HR and HRV measurements. For this purpose, sixty-seven volunteers performed a test consisting of the following consecutive segments: sitting rest, three submaximal exercise intensities in cycle-ergometer and sitting recovery. The agreement between HRV indices derived from Polar H7 and a simultaneous electrocardiogram (ECG) was assessed using concordance correlation coefficient (CCC). The percentage of subjects not reaching excellent agreement (CCC > 0.90) was higher for high-frequency power (PHF) than for low-frequency power (PLF) of HRV and increased with exercise intensity. A cluster of unfit and not young volunteers with high trunk fat percentage showed the highest error in HRV indices. This study indicates that Polar H7 and ECG were interchangeable at rest. During exercise, HR and PLF showed excellent agreement between devices. However, during the highest exercise intensity, CCC for PHF was lower than 0.90 in as many as 60% of the volunteers. During recovery, HR but not HRV measurements were accurate. As a conclusion, phenotypic differences between subjects can represent one of the causes for disagreement between HR sensors and ECG devices, which should be considered specifically when using Polar H7 and, generally, in the validation of any HR sensor for HRV analysis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Feasibility of atrial fibrillation detection from a novel wearable armband device

  • Bashar, Syed Khairul
  • Hossain, Md-Billal
  • Lázaro Plaza, Jesús
  • Ding, Eric Y.
  • Noh, Yeonsik
  • Cho, Chae Ho
  • McManus, David D.
  • Fitzgibbons, Timothy P.
  • Chon, Ki H.
Background Atrial fibrillation (AF) is the world’s most common heart rhythm disorder and even several minutes of AF episodes can contribute to risk for complications, including stroke. However, AF often goes undiagnosed owing to the fact that it can be paroxysmal, brief, and asymptomatic. Objective To facilitate better AF monitoring, we studied the feasibility of AF detection using a continuous electrocardiogram (ECG) signal recorded from a novel wearable armband device. Methods In our 2-step algorithm, we first calculate the R-R interval variability–based features to capture randomness that can indicate a segment of data possibly containing AF, and subsequently discriminate normal sinus rhythm from the possible AF episodes. Next, we use density Poincaré plot-derived image domain features along with a support vector machine to separate premature atrial/ventricular contraction episodes from any AF episodes. We trained and validated our model using the ECG data obtained from a subset of the MIMIC-III (Medical Information Mart for Intensive Care III) database containing 30 subjects. Results When we tested our model using the novel wearable armband ECG dataset containing 12 subjects, the proposed method achieved sensitivity, specificity, accuracy, and F1 score of 99.89%, 99.99%, 99.98%, and 0.9989, respectively. Moreover, when compared with several existing methods with the armband data, our proposed method outperformed the others, which shows its efficacy. Conclusion Our study suggests that the novel wearable armband device and our algorithm can be used as a potential tool for continuous AF monitoring with high accuracy.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Impact of the PPG sampling rate in the pulse rate variability indices evaluating several fiducial points in different pulse waveforms

  • Peláez-Coca, María Dolores
  • Hernando, Alberto
  • Lázaro, Jesús
  • Gil, Eduardo
The main aim of this work is to study the effect of the sampling rate of the photoplethysmographic (PPG) signal for pulse rate variability (PRV) analysis in the time and frequency domains, in stationary conditions. Forehead and finger PPG signals were recorded at 1000 Hz during a rest state, with red and infrared wavelengths, simultaneously with the electrocardiogram (ECG). The PPG sampling rate has been reduced by decimation, obtaining signals at 500 Hz, 250 Hz, 125 Hz, 100 Hz, 50 Hz and 25 Hz. Five fiducial points were computed: apex, up-slope, medium, line-medium and medium interpolate point. The medium point is located in the middle of the up-slope of the pulse. The medium interpolate point is a new proposal as fiducial point that consider the abrupt up-slope of the PPG pulse, so it can be recovered by linear interpolation when the sampling rate is reduced. The error performed in the temporal location of the fiducial points was computed. Pulse period time interval series were obtained from all PPG signals and fiducial points, and compared with the RR intervals obtained from the ECG. Heart rate variability and PRV signals were estimated and classical time and frequency domain indices were computed. The results showed that the medium interpolate point of the PPG pulse was the most accurate fiducial point under different PPG morphologies and sensor locations, when sampling rate was reduced. The error in the temporal location points and in the estimation of time and frequency indices was always lower when medium interpolate point was used for all considered sampling rates and for both signals, finger and forehead. The results also showed that the sampling rate of PPG signal can be reduced up to 100 Hz without causing significant changes in the time and frequency indices, when medium interpolate point was used as fiducial point. Therefore, the use of the medium interpolate point is recommended when working at low sampling rates.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiopulmonary coupling indices to assess weaning readiness from mechanical ventilation

  • Armañac-Julian, Pablo
  • Hernando, David
  • Lázaro, Jesús
  • Haro, Candelaria de
  • Magrans, Rudys
  • Morales, John
  • Moeyersons, Jonathan
  • Sarlabous, Leonardo
  • López-Aguilar, Josefina
  • Subirà, Carles
  • Fernández, Rafael
  • Orini, Michele
  • Laguna, Pablo
  • Varon, Carolina
  • Gil, Eduardo
  • Bailón, Raquel
  • Blanch, Lluís
The ideal moment to withdraw respiratory supply of patients under Mechanical Ventilation at Intensive Care Units (ICU), is not easy to be determined for clinicians. Although the Spontaneous Breathing Trial (SBT) provides a measure of the patients’ readiness, there is still around 15–20% of predictive failure rate. This work is a proof of concept focused on adding new value to the prediction of the weaning outcome. Heart Rate Variability (HRV) and Cardiopulmonary Coupling (CPC) methods are evaluated as new complementary estimates to assess weaning readiness. The CPC is related to how the mechanisms regulating respiration and cardiac pumping are working simultaneously, and it is defined from HRV in combination with respiratory information. Three different techniques are used to estimate the CPC, including Time-Frequency Coherence, Dynamic Mutual Information and Orthogonal Subspace Projections. The cohort study includes 22 patients in pressure support ventilation, ready to undergo the SBT, analysed in the 24 h previous to the SBT. Of these, 13 had a successful weaning and 9 failed the SBT or needed reintubation –being both considered as failed weaning. Results illustrate that traditional variables such as heart rate, respiratory frequency, and the parameters derived from HRV do not differ in patients with successful or failed weaning. Results revealed that HRV parameters can vary considerably depending on the time at which they are measured. This fact could be attributed to circadian rhythms, having a strong influence on HRV values. On the contrary, significant statistical differences are found in the proposed CPC parameters when comparing the values of the two groups, and throughout the whole recordings. In addition, differences are greater at night, probably because patients with failed weaning might be experiencing more respiratory episodes, e.g. apneas during the night, which is directly related to a reduced respiratory sinus arrhythmia. Therefore, results suggest that the traditional measures could be used in combination with the proposed CPC biomarkers to improve weaning readiness.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Estimation of the second ventilatory threshold through ventricular repolarization profile analysis

  • Milagro, J.
  • Hernández-Vicente, A.
  • Hernando, D.
  • Casajús, J.A.
  • Garatachea, N.
  • Bailón, R.
  • Pueyo, E.
Under the hypothesis that sympathetic control of ventricular repolarization may change once the second ventilatory threshold (VT2) has been reached, a novel methodology for non-invasive VT2 estimation based on the analysis of the T wave from the electrocardiogram (ECG) is proposed, and potential underlying physiological mechanisms are suggested. 25 volunteers (33.4 ± 5.2 years) underwent an incremental power cycle ergometer test (25 W/minute). During the test, respiratory gas exchange and multi-lead ECG were acquired. The former was employed to determine VT2, used here as a reference, whereas the latter was used to compute the temporal profiles of an index of ventricular repolarization instability (dT) and its low-frequency (LF) oscillations (LFdT). The sudden increases observed in dT and LFdT profiles above an established heart rate threshold were employed to derive VT2 estimates, referred to as VT2dT and VT2LFdT, respectively. Estimation errors of -4.7 ± 25.2 W were obtained when considering VT2dT. Errors were lower than the one-minute power increment of 25 W in 68% of the subjects and lower than 50 W in 89.5% of them. When using VT2LFdT, estimation error was of 15.3 ± 32.4 W. Most of the subjects shared common characteristic dT and LFdT profiles, which could be reflecting changes in the autonomic control of ventricular repolarization before and after reaching VT2. The analysis of ventricular repolarization dynamics during exercise allows non-invasive ECG-based estimation of VT2, possibly in relation to changes in the autonomic control of ventricular electrical activity when VT2 is reached.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Proposal for a home sleep monitoring platform employing a smart glove

  • Lazazzera, Remo
  • Laguna, Pablo
  • Gil, Eduardo
  • Carrault, Guy
The present paper proposes the design of a sleep monitoring platform. It consists of an entire sleep monitoring system based on a smart glove sensor called UpNEA worn during the night for signals acquisition, a mobile application, and a remote server called AeneA for cloud computing. UpNEA acquires a 3-axis accelerometer signal, a photoplethysmography (PPG), and a peripheral oxygen saturation (SpO2) signal from the index finger. Overnight recordings are sent from the hardware to a mobile application and then transferred to AeneA. After cloud computing, the results are shown in a web application, accessible for the user and the clinician. The AeneA sleep monitoring activity performs different tasks: sleep stages classification and oxygen desaturation assessment; heart rate and respiration rate estimation; tachycardia, bradycardia, atrial fibrillation, and premature ventricular contraction detection; and apnea and hypopnea identification and classification. The PPG breathing rate estimation algorithm showed an absolute median error of 0.5 breaths per minute for the 32 s window and 0.2 for the 64 s window. The apnea and hypopnea detection algorithm showed an accuracy (Acc) of 75.1%, by windowing the PPG in one-minute segments. The classification task revealed 92.6% Acc in separating central from obstructive apnea, 83.7% in separating central apnea from central hypopnea and 82.7% in separating obstructive apnea from obstructive hypopnea. The novelty of the integrated algorithms and the top-notch cloud computing products deployed, encourage the production of the proposed solution for home sleep monitoring.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

QT variability unrelated to RR variability during stress testing for identification of coronary artery disease

  • González del Castillo, Marta
  • Hernando, David
  • Orini, Michele
  • Laguna, Pablo
  • Viik, Jari
  • Bailón, Raquel
  • Pueyo, Esther
Stress test electrocardiogram (ECG) analysis is widely used for coronary artery disease (CAD) diagnosis despite its limited accuracy. Alterations in autonomic modulation of cardiac electrical activity have been reported in CAD patients during acute ischemia. We hypothesized that those alterations could be reflected in changes in ventricular repolarization dynamics during stress testing that could be measured through QT interval variability (QTV). However, QTV is largely dependent on RR interval variability (RRV), which might hinder intrinsic ventricular repolarization dynamics. In this study, we investigated whether different markers accounting for low-frequency (LF) oscillations of QTV unrelated to RRV during stress testing could be used to separate patients with and without CAD. Power spectral density of QTV unrelated to RRV was obtained based on time-frequency coherence estimation. Instantaneous LF power of QTV and QTV unrelated to RRV were obtained. LF power of QTV unrelated to RRV normalized by LF power of QTV was also studied. Stress test ECG of 100 patients were analysed. Patients referred to coronary angiography were classified into non-CAD or CAD group. LF oscillations in QTV did not show significant differences between CAD and non-CAD groups. However, LF oscillations in QTV unrelated to RRV were significantly higher in the CAD group as compared with the non-CAD group when measured during the first phases of exercise and last phases of recovery. ROC analysis of these indices revealed area under the curve values ranging from 61 to 73%. Binomial logistic regression analysis revealed LF power of QTV unrelated to RRV, both during the first phase of exercise and last phase of recovery, as independent predictors of CAD. In conclusion, this study highlights the importance of removing the influence of RRV when measuring QTV during stress testing for CAD identification and supports the added value of LF oscillations of QTV unrelated to RRV to diagnose CAD from the first minutes of exercise. This article is part of the theme issue 'Advanced computation in cardiovascular physiology: new challenges and opportunities'.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Reliability of pulse photoplethysmography sensors: Coverage using different setups and body locations

  • Armañac-Julián, Pablo
  • Kontaxis, Spyridon
  • Rapalis, Andrius
  • Marozas, Vaidotas
  • Laguna, Pablo
  • Bailón, Raquel
  • Gil, Eduardo
  • Lázaro, Jesús
Pulse photoplethysmography (PPG) is a simple and economical technique for obtaining cardiovascular information. In fact, PPG has become a very popular technology among wearable devices. However, the PPG signal is well-known to be very vulnerable to artifacts, and a good quality signal cannot be expected for most of the time in daily life. The percentage of time that a given measurement can be estimated (e.g., pulse rate) is denoted coverage (C), and it is highly dependent on the subject activity and on the configuration of the sensor, location, and stability of contact. This work aims to quantify the coverage of PPG sensors, using the simultaneously recorded electrocardiogram as a reference, with the PPG recorded at different places in the body and under different stress conditions. While many previous works analyzed the feasibility of PPG as a surrogate for heart rate variability analysis, there exists no previous work studying coverage to derive other cardiovascular indices. We report the coverage not only for estimating pulse rate (PR) but also for estimating pulse arrival time (PAT) and pulse amplitude variability (PAV). Three different datasets are analyzed for this purpose, consisting of a tilt-table test, an acute emotional stress test, and a heat stress test. The datasets include 19, 120, and 51 subjects, respectively, with PPG at the finger and at the forehead for the first two datasets and at the earlobe, in addition, for the latter. C ranges from 70% to 90% for estimating PR. Regarding the estimation of PAT, C ranges from 50% to 90%, and this is very dependent on the PPG sensor location, PPG quality, and the fiducial point (FP) chosen for the delineation of PPG. In fact, the delineation of the FP is critical in time for estimating derived series such as PAT due to the small dynamic range of these series. For the estimation of PAV, the C rates are between 70% and 90%. In general, lower C rates have been obtained for the PPG at the forehead. No difference in C has been observed between using PPG at the finger or at the earlobe. Then, the benefits of using either will depend on the application. However, different C rates are obtained using the same PPG signal, depending on the FP chosen for delineation. Lower C is reported when using the apex point of the PPG instead of the maximum flow velocity or the basal point, with a difference from 1% to even 10%. For further studies, each setup should first be analyzed and validated, taking the results and guidelines presented in this work into account, to study the feasibility of its recording devices with respect to each specific application.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Ventilatory Thresholds Estimation Based on ECG-derived Respiratory Rate

  • Garcia, Diego
  • Kontaxis, Spyridon
  • Hernandez-Vicente, Adrian
  • Hernando, David
  • Milagro, Javier
  • Pueyo, Esther
  • Garatachea, Nuria
  • Bailon, Raquel
  • Lazaro, Jesus
The purpose of this work is to study the feasibility of estimating the first and second ventilatory thresholds (VT1 and VT2, respectively) by using electrocardiogram (ECG)-derived respiratory rate during exercise testing. The ECGs of 25 healthy volunteers during cycle ergometer exercise test with increasing workload were analyzed. Time-varying respiratory rate was estimated from an ECG-derived respiration signal obtained from QRS slopes' range method. VT1 and VT2 were estimated as the points of maximum change in respiratory rate slope using polynomial spline smoothing. Reference VT1 and VT2 were determined from the ventilatory equivalents of O2 and CO2. Estimation errors (in watts) of -13.96 (54.84) W for VT1 and -8.06 (39.63) Wfor VT2 (median (interquartile range)) were obtained, suggesting that ventilatory thresholds can be estimated from solely the ECG signal.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic Nervous System characterization in hyperbaric environments considering respiratory component and non-linear analysis of Heart Rate Variability

  • Hernando, A.
  • Posada Quintero, H.
  • Peláez Coca, M. D.
  • Gil, E.
  • Chon, K. H.
Objectives: an evaluation of Principal Dynamic Mode (PDM) and Orthogonal Subspace Projection (OSP) methods to characterize the Autonomic Nervous System (ANS) response in three different hyperbaric environments was performed. Methods: ECG signals were recorded in two different stages (baseline and immersion) in three different hyperbaric environments: (a) inside a hyperbaric chamber, (b) in a controlled sea immersion, (c) in a real reservoir immersion. Time-domain parameters were extracted from the RR series of the ECG. From the Heart Rate Variability signal (HRV), classic Power Spectral Density (PSD), PDM (a non-linear analysis of HRV which is able to separate sympathetic and parasympathetic activities) and OSP (an analysis of HRV which is able to extract the respiratory component) methods were used to assess the ANS response. Results: PDM and OSP parameters follows the same trend when compared to the PSD ones for the hyperbaric chamber dataset. Comparing the three hyperbaric scenarios, significant differences were found: i) heart rate decreased and RMSSD increased in the hyperbaric chamber and the controlled dive, but they had the opposite behavior during the uncontrolled dive; ii) power in the OSP respiratory component was lower than power in the OSP residual component in cases a and c; iii) PDM and OSP methods showed a significant increase in sympathetic activity during both dives, but parasympathetic activity increased only during the uncontrolled dive. Conclusions: PDM and OSP methods could be used as an alternative measurement of ANS response instead of the PSD method. OSP results indicate that most of the variation in the heart rate variability cannot be described by changes in the respiration, so changes in ANS response can be assigned to other factors. Time-domain parameters reflect vagal activation in the hyperbaric chamber and in the controlled dive because of the effect of pressure. In the uncontrolled dive, sympathetic activity seems to be dominant, due to the effects of other factors such as physical activity, the challenging environment, and the influence of breathing through the scuba mask during immersion. In sum, a careful description of the changes in all the possible factors that could affect the ANS response between baseline and immersion stages in hyperbaric environments is needed for better interpretation of the results.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Blunted autonomic reactivity to mental stress in depression quantified by nonlinear cardiorespiratory coupling indices

  • Kontaxis, Spyridon
  • Laguna, Pablo
  • García Pages, Esther
  • Posadas-de Miguel, Mar
  • Siddi, Sara
  • Luisa Bernal, Maria
  • Maria Haro, Josep
  • Aguiló, Jordi
  • de la Camara, Concepción
  • Bailón, Raquel
  • Gil, Eduardo
In this study, differences in autonomic reactivity to mental stress between Major Depressive Disorder (MDD) patients and healthy control (HC) subjects are assessed by nonlinear cardiorespiratory coupling indices derived from the Real Wavelet Biphase. The degree and strength of Quadratic Phase Coupling (QPC) between interacting oscillations of Heart Rate Variability (HRV) and respiration are quantified before, during and after the execution of acognitive task. Results show that the QPC strength and QPC degree between the respiration and the respiratory sinus arrhythmia component of HRV were lower in HC compared to MDD during stress, suggesting that the parasympathetic branch was less inhibited in MDD patients. During recovery, only in HC group, this degree of QPC increased, while the respiratory rate was reduced, compared to the basal stage. The degree of QPC between the respiration and components of HRV in the low frequency band ([0.04, 0.15] Hz) increased in HC during stress, compared to the basal stage, while remained unchanged in MDD patients. These results imply that depression is associated with blunted autonomic reactivity to mental stress
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Wearable-based assessment of heart rate response to physical stressors in patients after open-heart surgery with frailty

  • Sokas, D.
  • Tamuleviciute-Prasciene, E.
  • Beigiene, A.
  • Barasaite, V.
  • Marozas, J.
  • Kubilius, R.
  • Bailón, R.
  • Petrenas, A.
Due to frailty, cardiac rehabilitation in older patients after open-heart surgery must be carefully tailored, thus calling for informative and convenient tools to assess the effectiveness of exercise training programs. The study investigates whether heart rate (HR) response to daily physical stressors can provide useful information when parameters are estimated using a wearable device. The study included 100 patients after open-heart surgery with frailty who were assigned to intervention and control groups. Both groups attended inpatient cardiac rehabilitation however only the patients of the intervention group performed exercises at home according to the tailored exercise training program. While performing maximal veloergometry test and submaximal tests, i.e., walking, stair-climbing, and stand up and go, HR response parameters were derived from a wearable-based electrocardiogram. All submaximal tests showed moderate to high correlation ( r = 0.59–0.72) with veloergometry for HR recovery and HR reserve parameters. While the effect of inpatient rehabilitation was only reflected by HR response to veloergometry, parameter trends over the entire exercise training program were also well followed during stair-climbing and walking. Based on study findings, HR response to walking should be considered for assessing the effectiveness of home-based exercise training programs in patients with frailty.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Decomposing photoplethysmogram waveforms into systolic and diastolic waves, with application to hyperbaric environments

  • Hernando, Alberto
  • Peláez-Coca, María Dolores
  • Gil, Eduardo
Objective: A new algorithm to decompose the photoplethysmogram (PPG) pulse in two waves related with the systolic and diastolic parts, was applied to identify alterations in the morphology of the PPG pulse due to the pressure. Approach: Each pulse was decomposed into two waves: the first one a Gaussian related with the systolic peak, and the second one was modelled as a lognormal curve associated with the diastolic part. From these two waves, 13 parameters related with the width (W1, W2 and W2/W1), the time instant (T1, T2, T21, TBB), the amplitude (A1, A2, A2/A1) and the areas (D1, D2, D2/D1) were estimated. These parameters were computed from subjects inside a hyperbaric chamber, involving five stages at different pressure: 1 atm, 3 atm, 5 atm, 3 atm and 1 atm. Main results: There was a significant increase in the values of A1, A2, W1, T1, and D1, and a decrease in the ratios when the pressure increased, that suggest a vasoconstriction when the pressure increased. There is also an increase in the values of , T2, T12, and W2 along the protocol, that implies a dependency of some parameters with the pulse-to-pulse interval. Significance: This methodology allows extracting a large set of parameters related with the PPG morphology that are affected by the change of pressure inside hyperbaric environments.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG ventricular repolarization dynamics during exercise: Temporal profile, relation to heart rate variability and effects of age and physical health

  • Hernández-Vicente, Adrián
  • Hernando, David
  • Vicente-Rodríguez, Germán
  • Bailón, Raquel
  • Garatachea, Nuria
  • Pueyo, Esther
Periodic repolarization dynamics (PRD) is a novel electrocardiographic marker of cardiac repolarization instability with powerful risk stratification capacity for total mortality and sudden cardiac death. Here, we use a time-frequency analysis approach to continuously quantify PRD at rest and during exercise, assess its dependence on heart rate variability (HRV) and characterize the effects of age (young adults/middle-aged adults/older adults), body mass index (non-overweight/overweight) and cardiorespiratory fitness level (fit/unfit). Sixty-six male volunteers performed an exercise test. RR and dT variabilities (RRV, dTV), as well as the fraction of dT variability unrelated to RR variability, were computed based on time-frequency representations. The instantaneous LF power of dT (PdTV), representing the same concept as PRD, and of its RRV-unrelated component (PdTVuRRV) were quantified. dT angle was found to mostly oscillate in the LF band. Overall, 50-70% of PdTV was linearly unrelated to RRV. The onset of exercise caused a sudden increase in PdTV and PdTVuRRV, which returned to pre-exercise levels during recovery. Clustering analysis identified a group of overweight and unfit individuals with significantly higher PdTV and PdTVuRRV values at rest than the rest of the population. Our findings shed new light on the temporal profile of PRD during exercise, its relationship to HRV and the differences in PRD between subjects according to phenotypic characteristics. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic Waveform and Pulse Rate Variability Analysis in Hyperbaric Environments

  • Peláez-Coca, Mª Dolores
  • Hernando, Alberto
  • Lozano, Mª Teresa
  • Sánchez, Carlos
  • Izquierdo, David
  • Gil, Eduardo
The main aim of this work is to identify alterations in the morphology of the pulse photoplethysmogram (PPG) signal, due to the exposure of the subjects to a hyperbaric environment. Additionally, their Pulse Rate Variability (PRV) is analysed to characterise the response of their Autonomic Nervous System (ANS). To do that, 28 volunteers are introduced into a hyperbaric chamber and five sequential stages with different atmospheric pressures (1 atm; descent to 3 and 5 atm; ascent to 3 and 1 atm) are performed. In this work, nineteen morphological parameters of the PPG signal are analysed: the amplitude of the PPG pulse; eight parameters related to pulse width; eight parameters related to pulse area; and the two slopes of the PPG pulse. Also, classical time and frequency parameters of PRV are computed. The relative change of all the parameters was calculated with respect to the initial baseline state at 1 atm. Notable widening of the pulses width is observed in the four stages analysed, together with a decrease in the PPG amplitude at the last ascent stages. The PPG area increases with pressure, with no significant changes when the initial pressure is recovered. These changes in PPG waveform may be caused by an increase in the systemic vascular resistance as a consequence of vasoconstriction. This phenomenon suggests a sympathetic activation, causing a vasoconstriction in the skin circulation, especially in the extremities. However, the PRV results show an augmented parasympathetic activity and a reduction in the parameters that characterise the sympathetic response. So, only a sympathetic activation is detected in the peripheral region, as reflected by PPG morphology. The information regarding the ANS and the cardiovascular response that can be extracted from the PPG signal, as well as its compatibility with wet conditions make this signal the most suitable for studying the physiological response in hyperbaric environments, including scuba diving activities.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Detection of Walk Tests in Free-Living Activities Using a Wrist-Worn Device

  • Sokas D.
  • Paliakaite B.
  • Rapalis A.
  • Marozas V.
  • Bailón R.
  • Petrenas A.
Exercise testing to assess the response to physical rehabilitation or lifestyle interventions is administered in clinics thus at best can be repeated only few times a year. This study explores a novel approach to collecting information on functional performance through walk tests, e.g., a 6-min walk test (6MWT), unintentionally performed in free-living activities. Walk tests are detected in step data provided by a wrist-worn device. Only those events of minute-to-minute variation in walking cadence, which is equal or lower than the empirically determined maximal SD (e.g., 5-steps), are considered as walk test candidates. Out of detected walk tests within the non-overlapping sliding time interval (e.g., 1-week), the one with the largest number of steps is chosen as the most representative. This approach is studied on a cohort of 99 subjects, assigned to the groups of patients with cardiovascular disease (CVD) and healthy subjects below and over 40-years-old, who were asked to wear the device while maintaining their usual physical activity regimen. The total wear time was 8, 864 subject-days after excluding the intervals of occasionally discontinued monitoring. About 82% (23/28) of patients with CVD and 88% (21/24) of healthy subjects over 40-years-old had at least a single 6MWT over the 1st month of monitoring. About 52% of patients with CVD (12/23) and 91% (19/21) of healthy subjects over 40-years-old exceeded 500 m. Patients with CVD, on average, walked 46 m shorter 6MWT distance (p = 0.04) compared to healthy subjects. Unintentional walk testing is feasible and could be valuable for repeated assessment of functional performance outside the clinical setting. © Copyright © 2021 Sokas, Paliakaite, Rapalis, Marozas, Bailón and Petrenas.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic Nervous System Response During Scuba Diving Activity

  • Hernando, Alberto
  • Dolores Pelaez Coca, María
  • Sánchez, Carlos
  • Juan, Bolea
  • Izquierdo, David
  • Teresa Lozano Albalate, María
  • Gil, Eduardo
In this work, Heart Rate Variability indices are computed to analyze the Autonomic Nervous System response during a scuba diving activity. To do that, electrocardiogram signals from 6 subjects were recorded in a reservoir immersion. Two different stages were analyzed: baseline stage, where subjects remained seated outside the water; and immersion stage, where subjects performed physical activity in a non-controlled environment. The smoothed pseudo Wigner-Ville distribution was used for the timefrequency analysis. Results show a statistically significant increase of the mean heart rate and a significant decrease in the root mean square of the successive normal beats during the immersion stage. However, frequencydomain parameters did not show any significant difference between stages. Whereas time-domain parameters reflect a sympathetic activation during the immersion, caused by the predominance of the physical activity and the stress of the challenging environment, frequency-domain parameters are not able to capture it. Further studies are needed to draw more robust conclusions by increasing the number of subjects and exploring alternative methods to compute the Autonomic Nervous System frequency content.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Cardiopulmonary coupling indices to assess weaning readiness from mechanical ventilation

  • Armañac-Julián, Pablo
  • Hernando, David
  • Lázaro, Jesús
  • De Haro, Candelaria
  • Magrans, Rudys
  • Morales, John
  • Moeyersons, Jonathan
  • Sarlabous, Leonardo
  • López-Aguilar, Josefina
  • Subirà Cuyàs, Carles
  • Fernández, Rafael
  • Orini, Michele
  • Laguna, Pablo
  • Varon, Carolina
  • Gil, Eduardo
  • Bailón, Raquel
  • Blanch, Lluís
Tis work was supported by CIBER in Bioengineering, Biomaterials & Nanomedicine and CIBER in Respiratory Diseases through Instituto de Salud Carlos III: INTERCIBER-PAI2017 ; by Ministerio de Economía y Competitividad (RTI2018-097723-B-I00), Gobierno de Aragón (Reference Group BSICoS T39-20R) cofunded by the Fondo Europeo de Desarrollo Regional (FEDER) 2014–2020 “Building Europe from Aragón”; by a personal grant to P. Armañac, Programa Ibercaja-CAI de Estancias de Investigación, code IT 9/19; by PI16/01606, PI19/01015, integrated in the Plan Nacional de R+D+I and co-funded by the ISCIII- Subdirección General de Evaluación and the FEDER; RTC-2017-6193-1 (AEI/FEDER UE); and by Fundació Parc Taulí. Tis study has also received funding from the European Union’s Framework Programme for Research and Innovation Horizon 2020 (2014–2020) under the Marie Skłodowska-Curie Grant Agreement No. 745755., The ideal moment to withdraw respiratory supply of patients under Mechanical Ventilation at Intensive Care Units (ICU), is not easy to be determined for clinicians. Although the Spontaneous Breathing Trial (SBT) provides a measure of the patients’ readiness, there is still around 15–20% of predictive failure rate. This work is a proof of concept focused on adding new value to the prediction of the weaning outcome. Heart Rate Variability (HRV) and Cardiopulmonary Coupling (CPC) methods are evaluated as new complementary estimates to assess weaning readiness. The CPC is related to how the mechanisms regulating respiration and cardiac pumping are working simultaneously, and it is defined from HRV in combination with respiratory information. Three different techniques are used to estimate the CPC, including Time-Frequency Coherence, Dynamic Mutual Information and Orthogonal Subspace Projections. The cohort study includes 22 patients in pressure support ventilation, ready to undergo the SBT, analysed in the 24 h previous to the SBT. Of these, 13 had a successful weaning and 9 failed the SBT or needed reintubation –being both considered as failed weaning. Results illustrate that traditional variables such as heart rate, respiratory frequency, and the parameters derived from HRV do not differ in patients with successful or failed weaning. Results revealed that HRV parameters can vary considerably depending on the time at which they are measured. This fact could be attributed to circadian rhythms, having a strong influence on HRV values. On the contrary, significant statistical differences are found in the proposed CPC parameters when comparing the values of the two groups, and throughout the whole recordings. In addition, differences are greater at night, probably because patients with failed weaning might be experiencing more respiratory episodes, e.g. apneas during the night, which is directly related to a reduced respiratory sinus arrhythmia. Therefore, results suggest that the traditional measures could be used in combination with the proposed CPC biomarkers to improve weaning readiness., info:eu-repo/semantics/publishedVersion
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Cardiopulmonary coupling indices to assess weaning readiness from mechanical ventilation

  • Armañac-Julián, Pablo
  • Hernando, David|||0000-0002-1462-4880
  • Lázaro, Jesús
  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Magrans, Rudys
  • Morales, John
  • Moeyersons, Jonathan
  • Sarlabous, Leonardo|||0000-0002-0495-8422
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Subirà, Carles|||0000-0003-2285-2311
  • Fernández, Rafael
  • Orini, Michele
  • Laguna, Pablo|||0000-0003-3434-9254
  • Varon, Carolina|||0000-0002-9581-0676
  • Gil, Eduardo
  • Bailón, Raquel|||0000-0003-1272-0550
  • Blanch, Lluís|||0000-0002-4158-7464
The ideal moment to withdraw respiratory supply of patients under Mechanical Ventilation at Intensive Care Units (ICU), is not easy to be determined for clinicians. Although the Spontaneous Breathing Trial (SBT) provides a measure of the patients' readiness, there is still around 15-20% of predictive failure rate. This work is a proof of concept focused on adding new value to the prediction of the weaning outcome. Heart Rate Variability (HRV) and Cardiopulmonary Coupling (CPC) methods are evaluated as new complementary estimates to assess weaning readiness. The CPC is related to how the mechanisms regulating respiration and cardiac pumping are working simultaneously, and it is defined from HRV in combination with respiratory information. Three different techniques are used to estimate the CPC, including Time-Frequency Coherence, Dynamic Mutual Information and Orthogonal Subspace Projections. The cohort study includes 22 patients in pressure support ventilation, ready to undergo the SBT, analysed in the 24 h previous to the SBT. Of these, 13 had a successful weaning and 9 failed the SBT or needed reintubation -being both considered as failed weaning. Results illustrate that traditional variables such as heart rate, respiratory frequency, and the parameters derived from HRV do not differ in patients with successful or failed weaning. Results revealed that HRV parameters can vary considerably depending on the time at which they are measured. This fact could be attributed to circadian rhythms, having a strong influence on HRV values. On the contrary, significant statistical differences are found in the proposed CPC parameters when comparing the values of the two groups, and throughout the whole recordings. In addition, differences are greater at night, probably because patients with failed weaning might be experiencing more respiratory episodes, e.g. apneas during the night, which is directly related to a reduced respiratory sinus arrhythmia. Therefore, results suggest that the traditional measures could be used in combination with the proposed CPC biomarkers to improve weaning readiness.
Dipòsit Digital de Documents de la UAB
Publicación Contribución de congreso (ConferenceOutput)

Heart Rate Variability Analysis Assessment for Asthma Control Stratification

  • Milagro, Javier|||0000-0002-7842-9611
  • Soto-Retes, Lorena|||0000-0001-6046-9204
  • Giner, Jordi|||0000-0002-3044-2059
  • Varon, Carolina|||0000-0002-9581-0676
  • Laguna, Pablo|||0000-0003-3434-9254
  • Plaza, Vicente|||0000-0003-2567-5496
  • Gil, Eduardo
  • Bailón, Raquel|||0000-0003-1272-0550
Autonomic nervous system (ANS) has been suggested to play a major role in the pathogenesis of asthma. This hypothesis has motivated large research, revealing a reduced modulation of the heart rate in subjects with uncontrolled asthma, when compared to asthmatics with controlled symptomatology. In this work, we assessed ANS activity through heart rate variability analysis in a group of asthmatics classified attending to the control of their symptoms. This information was later used for training a logistic regression classifier aiming at differentiating between the levels of control in asthmatic patients. The accuracy of the classifier improved when including ANS information (71.77%, versus 64.73% when only clinical parameters were considered), suggesting that ANS assessment could contribute to better non-invasive asthma monitoring.