Pasar al contenido principal

CARACTERIZACION Y MODELADO DE LA RESPUESTA FISIOLOGICA EN ENTORNOS HIPERBARICOS VARIABLES

PGC2018-095936-B-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de Generación de Conocimiento y Fortalecimiento Científico y Tecnológico del Sistema de I+D+i
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D (Excelencia / Generación de Conocimiento)
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario CENTRO UNIVERSITARIO DE DEFENSA ACADEMIA GENERAL MILITAR

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Finger and forehead PPG signal comparison for respiratory rate estimation

  • Hernando, Alberto
  • Peláez-Coca, María Dolores
  • Lozano, María Teresa
  • Lázaro, Jesús
  • Gil, Eduardo
Objective: an evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. Approach: finger-PPG, forehead-PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability (PWV), pulse amplitude variability (PAV) and the respiratory- induced intensity variability (RIIV). Respiratory rate was estimated from each one of the 4 PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. Main results: results show a better performance in terms of successful estimation and relative error when: i) PPG signal is recorded in the finger; ii) the respiratory rate is less than 0.4 Hz; iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. Significance: these results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that finger is better than forehead to estimate respiratory rate.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Impact of the PPG sampling rate in the pulse rate variability indices evaluating several fiducial points in different pulse waveforms

  • Peláez-Coca, María Dolores
  • Hernando, Alberto
  • Lázaro, Jesús
  • Gil, Eduardo
The main aim of this work is to study the effect of the sampling rate of the photoplethysmographic (PPG) signal for pulse rate variability (PRV) analysis in the time and frequency domains, in stationary conditions. Forehead and finger PPG signals were recorded at 1000 Hz during a rest state, with red and infrared wavelengths, simultaneously with the electrocardiogram (ECG). The PPG sampling rate has been reduced by decimation, obtaining signals at 500 Hz, 250 Hz, 125 Hz, 100 Hz, 50 Hz and 25 Hz. Five fiducial points were computed: apex, up-slope, medium, line-medium and medium interpolate point. The medium point is located in the middle of the up-slope of the pulse. The medium interpolate point is a new proposal as fiducial point that consider the abrupt up-slope of the PPG pulse, so it can be recovered by linear interpolation when the sampling rate is reduced. The error performed in the temporal location of the fiducial points was computed. Pulse period time interval series were obtained from all PPG signals and fiducial points, and compared with the RR intervals obtained from the ECG. Heart rate variability and PRV signals were estimated and classical time and frequency domain indices were computed. The results showed that the medium interpolate point of the PPG pulse was the most accurate fiducial point under different PPG morphologies and sensor locations, when sampling rate was reduced. The error in the temporal location points and in the estimation of time and frequency indices was always lower when medium interpolate point was used for all considered sampling rates and for both signals, finger and forehead. The results also showed that the sampling rate of PPG signal can be reduced up to 100 Hz without causing significant changes in the time and frequency indices, when medium interpolate point was used as fiducial point. Therefore, the use of the medium interpolate point is recommended when working at low sampling rates.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic Nervous System characterization in hyperbaric environments considering respiratory component and non-linear analysis of Heart Rate Variability

  • Hernando, A.
  • Posada Quintero, H.
  • Peláez Coca, M. D.
  • Gil, E.
  • Chon, K. H.
Objectives: an evaluation of Principal Dynamic Mode (PDM) and Orthogonal Subspace Projection (OSP) methods to characterize the Autonomic Nervous System (ANS) response in three different hyperbaric environments was performed. Methods: ECG signals were recorded in two different stages (baseline and immersion) in three different hyperbaric environments: (a) inside a hyperbaric chamber, (b) in a controlled sea immersion, (c) in a real reservoir immersion. Time-domain parameters were extracted from the RR series of the ECG. From the Heart Rate Variability signal (HRV), classic Power Spectral Density (PSD), PDM (a non-linear analysis of HRV which is able to separate sympathetic and parasympathetic activities) and OSP (an analysis of HRV which is able to extract the respiratory component) methods were used to assess the ANS response. Results: PDM and OSP parameters follows the same trend when compared to the PSD ones for the hyperbaric chamber dataset. Comparing the three hyperbaric scenarios, significant differences were found: i) heart rate decreased and RMSSD increased in the hyperbaric chamber and the controlled dive, but they had the opposite behavior during the uncontrolled dive; ii) power in the OSP respiratory component was lower than power in the OSP residual component in cases a and c; iii) PDM and OSP methods showed a significant increase in sympathetic activity during both dives, but parasympathetic activity increased only during the uncontrolled dive. Conclusions: PDM and OSP methods could be used as an alternative measurement of ANS response instead of the PSD method. OSP results indicate that most of the variation in the heart rate variability cannot be described by changes in the respiration, so changes in ANS response can be assigned to other factors. Time-domain parameters reflect vagal activation in the hyperbaric chamber and in the controlled dive because of the effect of pressure. In the uncontrolled dive, sympathetic activity seems to be dominant, due to the effects of other factors such as physical activity, the challenging environment, and the influence of breathing through the scuba mask during immersion. In sum, a careful description of the changes in all the possible factors that could affect the ANS response between baseline and immersion stages in hyperbaric environments is needed for better interpretation of the results.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Enhancing safety in hyperbaric environments through analysis of autonomic nervous system responses: a comparison of dry and humid conditions

  • Sánchez, Carlos
  • Hernando, Alberto
  • Bolea, Juan
  • Izquierdo, David
  • Rodríguez, Germán
  • Olea, Agustín
  • Lozano, María Teresa
  • Peláez-Coca, María Dolores
Diving can have significant cardiovascular effects on the human body and increase the risk of developing cardiac health issues. This study aimed to investigate the autonomic nervous system (ANS) responses of healthy individuals during simulated dives in hyperbaric chambers and explore the effects of the humid environment on these responses. Electrocardiographic- and heart-rate-variability (HRV)-derived indices were analyzed, and their statistical ranges were compared at different depths during simulated immersions under dry and humid conditions. The results showed that humidity significantly affected the ANS responses of the subjects, leading to reduced parasympathetic activity and increased sympathetic dominance. The power of the high-frequency band of the HRV after removing the influence of respiration, PHF⊥¯, and the number of pairs of successive normal-to-normal intervals that differ by more than 50 ms divided by the total number of normal-to-normal intervals, pNN50¯, indices were found to be the most informative in distinguishing the ANS responses of subjects between the two datasets. Additionally, the statistical ranges of the HRV indices were calculated, and the classification of subjects as “normal” or “abnormal” was determined based on these ranges. The results showed that the ranges were effective at identifying abnormal ANS responses, indicating the potential use of these ranges as a reference for monitoring the activity of divers and avoiding future immersions if many indices are out of the normal ranges. The bagging method was also used to include some variability in the datasets’ ranges, and the classification results showed that the ranges computed without proper bagging represent reality and its associated variability. Overall, this study provides valuable insights into the ANS responses of healthy individuals during simulated dives in hyperbaric chambers and the effects of humidity on these responses.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Decomposing photoplethysmogram waveforms into systolic and diastolic waves, with application to hyperbaric environments

  • Hernando, Alberto
  • Peláez-Coca, María Dolores
  • Gil, Eduardo
Objective: A new algorithm to decompose the photoplethysmogram (PPG) pulse in two waves related with the systolic and diastolic parts, was applied to identify alterations in the morphology of the PPG pulse due to the pressure. Approach: Each pulse was decomposed into two waves: the first one a Gaussian related with the systolic peak, and the second one was modelled as a lognormal curve associated with the diastolic part. From these two waves, 13 parameters related with the width (W1, W2 and W2/W1), the time instant (T1, T2, T21, TBB), the amplitude (A1, A2, A2/A1) and the areas (D1, D2, D2/D1) were estimated. These parameters were computed from subjects inside a hyperbaric chamber, involving five stages at different pressure: 1 atm, 3 atm, 5 atm, 3 atm and 1 atm. Main results: There was a significant increase in the values of A1, A2, W1, T1, and D1, and a decrease in the ratios when the pressure increased, that suggest a vasoconstriction when the pressure increased. There is also an increase in the values of , T2, T12, and W2 along the protocol, that implies a dependency of some parameters with the pulse-to-pulse interval. Significance: This methodology allows extracting a large set of parameters related with the PPG morphology that are affected by the change of pressure inside hyperbaric environments.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic Waveform and Pulse Rate Variability Analysis in Hyperbaric Environments

  • Peláez-Coca, Mª Dolores
  • Hernando, Alberto
  • Lozano, Mª Teresa
  • Sánchez, Carlos
  • Izquierdo, David
  • Gil, Eduardo
The main aim of this work is to identify alterations in the morphology of the pulse photoplethysmogram (PPG) signal, due to the exposure of the subjects to a hyperbaric environment. Additionally, their Pulse Rate Variability (PRV) is analysed to characterise the response of their Autonomic Nervous System (ANS). To do that, 28 volunteers are introduced into a hyperbaric chamber and five sequential stages with different atmospheric pressures (1 atm; descent to 3 and 5 atm; ascent to 3 and 1 atm) are performed. In this work, nineteen morphological parameters of the PPG signal are analysed: the amplitude of the PPG pulse; eight parameters related to pulse width; eight parameters related to pulse area; and the two slopes of the PPG pulse. Also, classical time and frequency parameters of PRV are computed. The relative change of all the parameters was calculated with respect to the initial baseline state at 1 atm. Notable widening of the pulses width is observed in the four stages analysed, together with a decrease in the PPG amplitude at the last ascent stages. The PPG area increases with pressure, with no significant changes when the initial pressure is recovered. These changes in PPG waveform may be caused by an increase in the systemic vascular resistance as a consequence of vasoconstriction. This phenomenon suggests a sympathetic activation, causing a vasoconstriction in the skin circulation, especially in the extremities. However, the PRV results show an augmented parasympathetic activity and a reduction in the parameters that characterise the sympathetic response. So, only a sympathetic activation is detected in the peripheral region, as reflected by PPG morphology. The information regarding the ANS and the cardiovascular response that can be extracted from the PPG signal, as well as its compatibility with wet conditions make this signal the most suitable for studying the physiological response in hyperbaric environments, including scuba diving activities.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Safety Ranges for Heart Rate Variability Parameters in Hyperbaric Environments

  • Sánchez, Carlos
  • Hernando, Alberto
  • Bolea, Juan
  • Izquierdo, David
  • Lozano Albalate, María Teresa
  • Pelaez Coca, María Dolores
The Autonomic Nervous System (ANS) tries to maintain homeostasis in hyperbaric environments, but its activity may present large variability between subjects. The aim of this study is to establish safety ranges for ANS-related indices derived from the electrocardiographic signal (ECG) during diving and use them to identify subjects with abnormal ANS response and avoid potential diving accidents. A database with ECG recordings from 28 subjects introduced into a hyperbaric chamber was used. During immersion, five stages were studied at 1, 3 and 5 atm during descent and ascent. Indices of heart rate variability, extracted from ECG, reflecting the sympathetic and parasympathetic ANS response, were calculated and regularised with respect to their values at the initial stage at 1 atm. In particular, four time-related parameters extracted from the RR series and four frequency parameters based on the powers of the low and high frequency bands were used. High inter-subject variability in the ANS response was observed in all stages. The eight parameters were analysed for each stage and, as a result, some subjects presented highly uncommon responses with higher chances of suffering a diving accident, reflected in many parameters out of the interquartile range. This allows establishing safety ranges for ANS-related parameters that can help in the identification of subjects with potential health risk.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic Nervous System Response During Scuba Diving Activity

  • Hernando, Alberto
  • Dolores Pelaez Coca, María
  • Sánchez, Carlos
  • Juan, Bolea
  • Izquierdo, David
  • Teresa Lozano Albalate, María
  • Gil, Eduardo
In this work, Heart Rate Variability indices are computed to analyze the Autonomic Nervous System response during a scuba diving activity. To do that, electrocardiogram signals from 6 subjects were recorded in a reservoir immersion. Two different stages were analyzed: baseline stage, where subjects remained seated outside the water; and immersion stage, where subjects performed physical activity in a non-controlled environment. The smoothed pseudo Wigner-Ville distribution was used for the timefrequency analysis. Results show a statistically significant increase of the mean heart rate and a significant decrease in the root mean square of the successive normal beats during the immersion stage. However, frequencydomain parameters did not show any significant difference between stages. Whereas time-domain parameters reflect a sympathetic activation during the immersion, caused by the predominance of the physical activity and the stress of the challenging environment, frequency-domain parameters are not able to capture it. Further studies are needed to draw more robust conclusions by increasing the number of subjects and exploring alternative methods to compute the Autonomic Nervous System frequency content.