Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Impact of the PPG sampling rate in the pulse rate variability indices evaluating several fiducial points in different pulse waveforms

  • Peláez-Coca, María Dolores
  • Hernando, Alberto
  • Lázaro, Jesús
  • Gil, Eduardo
The main aim of this work is to study the effect of the sampling rate of the photoplethysmographic (PPG) signal for pulse rate variability (PRV) analysis in the time and frequency domains, in stationary conditions. Forehead and finger PPG signals were recorded at 1000 Hz during a rest state, with red and infrared wavelengths, simultaneously with the electrocardiogram (ECG). The PPG sampling rate has been reduced by decimation, obtaining signals at 500 Hz, 250 Hz, 125 Hz, 100 Hz, 50 Hz and 25 Hz. Five fiducial points were computed: apex, up-slope, medium, line-medium and medium interpolate point. The medium point is located in the middle of the up-slope of the pulse. The medium interpolate point is a new proposal as fiducial point that consider the abrupt up-slope of the PPG pulse, so it can be recovered by linear interpolation when the sampling rate is reduced. The error performed in the temporal location of the fiducial points was computed. Pulse period time interval series were obtained from all PPG signals and fiducial points, and compared with the RR intervals obtained from the ECG. Heart rate variability and PRV signals were estimated and classical time and frequency domain indices were computed. The results showed that the medium interpolate point of the PPG pulse was the most accurate fiducial point under different PPG morphologies and sensor locations, when sampling rate was reduced. The error in the temporal location points and in the estimation of time and frequency indices was always lower when medium interpolate point was used for all considered sampling rates and for both signals, finger and forehead. The results also showed that the sampling rate of PPG signal can be reduced up to 100 Hz without causing significant changes in the time and frequency indices, when medium interpolate point was used as fiducial point. Therefore, the use of the medium interpolate point is recommended when working at low sampling rates.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic Nervous System characterization in hyperbaric environments considering respiratory component and non-linear analysis of Heart Rate Variability

  • Hernando, A.
  • Posada Quintero, H.
  • Peláez Coca, M. D.
  • Gil, E.
  • Chon, K. H.
Objectives: an evaluation of Principal Dynamic Mode (PDM) and Orthogonal Subspace Projection (OSP) methods to characterize the Autonomic Nervous System (ANS) response in three different hyperbaric environments was performed. Methods: ECG signals were recorded in two different stages (baseline and immersion) in three different hyperbaric environments: (a) inside a hyperbaric chamber, (b) in a controlled sea immersion, (c) in a real reservoir immersion. Time-domain parameters were extracted from the RR series of the ECG. From the Heart Rate Variability signal (HRV), classic Power Spectral Density (PSD), PDM (a non-linear analysis of HRV which is able to separate sympathetic and parasympathetic activities) and OSP (an analysis of HRV which is able to extract the respiratory component) methods were used to assess the ANS response. Results: PDM and OSP parameters follows the same trend when compared to the PSD ones for the hyperbaric chamber dataset. Comparing the three hyperbaric scenarios, significant differences were found: i) heart rate decreased and RMSSD increased in the hyperbaric chamber and the controlled dive, but they had the opposite behavior during the uncontrolled dive; ii) power in the OSP respiratory component was lower than power in the OSP residual component in cases a and c; iii) PDM and OSP methods showed a significant increase in sympathetic activity during both dives, but parasympathetic activity increased only during the uncontrolled dive. Conclusions: PDM and OSP methods could be used as an alternative measurement of ANS response instead of the PSD method. OSP results indicate that most of the variation in the heart rate variability cannot be described by changes in the respiration, so changes in ANS response can be assigned to other factors. Time-domain parameters reflect vagal activation in the hyperbaric chamber and in the controlled dive because of the effect of pressure. In the uncontrolled dive, sympathetic activity seems to be dominant, due to the effects of other factors such as physical activity, the challenging environment, and the influence of breathing through the scuba mask during immersion. In sum, a careful description of the changes in all the possible factors that could affect the ANS response between baseline and immersion stages in hyperbaric environments is needed for better interpretation of the results.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Enhancing safety in hyperbaric environments through analysis of autonomic nervous system responses: a comparison of dry and humid conditions

  • Sánchez, Carlos
  • Hernando, Alberto
  • Bolea, Juan
  • Izquierdo, David
  • Rodríguez, Germán
  • Olea, Agustín
  • Lozano, María Teresa
  • Peláez-Coca, María Dolores
Diving can have significant cardiovascular effects on the human body and increase the risk of developing cardiac health issues. This study aimed to investigate the autonomic nervous system (ANS) responses of healthy individuals during simulated dives in hyperbaric chambers and explore the effects of the humid environment on these responses. Electrocardiographic- and heart-rate-variability (HRV)-derived indices were analyzed, and their statistical ranges were compared at different depths during simulated immersions under dry and humid conditions. The results showed that humidity significantly affected the ANS responses of the subjects, leading to reduced parasympathetic activity and increased sympathetic dominance. The power of the high-frequency band of the HRV after removing the influence of respiration, PHF⊥¯, and the number of pairs of successive normal-to-normal intervals that differ by more than 50 ms divided by the total number of normal-to-normal intervals, pNN50¯, indices were found to be the most informative in distinguishing the ANS responses of subjects between the two datasets. Additionally, the statistical ranges of the HRV indices were calculated, and the classification of subjects as “normal” or “abnormal” was determined based on these ranges. The results showed that the ranges were effective at identifying abnormal ANS responses, indicating the potential use of these ranges as a reference for monitoring the activity of divers and avoiding future immersions if many indices are out of the normal ranges. The bagging method was also used to include some variability in the datasets’ ranges, and the classification results showed that the ranges computed without proper bagging represent reality and its associated variability. Overall, this study provides valuable insights into the ANS responses of healthy individuals during simulated dives in hyperbaric chambers and the effects of humidity on these responses.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Safety Ranges for Heart Rate Variability Parameters in Hyperbaric Environments

  • Sánchez, Carlos
  • Hernando, Alberto
  • Bolea, Juan
  • Izquierdo, David
  • Lozano Albalate, María Teresa
  • Pelaez Coca, María Dolores
The Autonomic Nervous System (ANS) tries to maintain homeostasis in hyperbaric environments, but its activity may present large variability between subjects. The aim of this study is to establish safety ranges for ANS-related indices derived from the electrocardiographic signal (ECG) during diving and use them to identify subjects with abnormal ANS response and avoid potential diving accidents. A database with ECG recordings from 28 subjects introduced into a hyperbaric chamber was used. During immersion, five stages were studied at 1, 3 and 5 atm during descent and ascent. Indices of heart rate variability, extracted from ECG, reflecting the sympathetic and parasympathetic ANS response, were calculated and regularised with respect to their values at the initial stage at 1 atm. In particular, four time-related parameters extracted from the RR series and four frequency parameters based on the powers of the low and high frequency bands were used. High inter-subject variability in the ANS response was observed in all stages. The eight parameters were analysed for each stage and, as a result, some subjects presented highly uncommon responses with higher chances of suffering a diving accident, reflected in many parameters out of the interquartile range. This allows establishing safety ranges for ANS-related parameters that can help in the identification of subjects with potential health risk.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic Nervous System Response During Scuba Diving Activity

  • Hernando, Alberto
  • Dolores Pelaez Coca, María
  • Sánchez, Carlos
  • Juan, Bolea
  • Izquierdo, David
  • Teresa Lozano Albalate, María
  • Gil, Eduardo
In this work, Heart Rate Variability indices are computed to analyze the Autonomic Nervous System response during a scuba diving activity. To do that, electrocardiogram signals from 6 subjects were recorded in a reservoir immersion. Two different stages were analyzed: baseline stage, where subjects remained seated outside the water; and immersion stage, where subjects performed physical activity in a non-controlled environment. The smoothed pseudo Wigner-Ville distribution was used for the timefrequency analysis. Results show a statistically significant increase of the mean heart rate and a significant decrease in the root mean square of the successive normal beats during the immersion stage. However, frequencydomain parameters did not show any significant difference between stages. Whereas time-domain parameters reflect a sympathetic activation during the immersion, caused by the predominance of the physical activity and the stress of the challenging environment, frequency-domain parameters are not able to capture it. Further studies are needed to draw more robust conclusions by increasing the number of subjects and exploring alternative methods to compute the Autonomic Nervous System frequency content.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Analysis of the Colorless Operation of a Calibrated 120° Coherent Receiver

  • Izquierdo, David
  • Clemente, Jesus
  • Reyes-Iglesias, Pedro
  • Ortega-Monux, Alejandro
  • Altabas, Jose
  • Molina-Fernandez, Inigo
  • Wanguemert-Perez, Juan Gonzalo
  • de Oliva-Rubio, Jose
  • Garces, Ignacio
The performance of an integrated InP 120° coherent receiver has been experimentally analyzed using 50 Gbps 16-QAM signals. IQ components are obtained through a set of coefficients applied to the three output photocurrents of the device. It is demonstrated that the calibration of these coefficients can compensate, without extra computational cost, fabrication hardware impairments and allows a wide optical bandwidth (up to 80 nm range) with a high interfering rejection capability. It has been experimentally verified colorless operation in the complete C-band for a received interfering power close to 11 dB above the signal level. This confirms a remarkable colorless behavior of our proposal.