Publicación Artículo científico (JournalArticle)

Reliability of pulse photoplethysmography sensors: Coverage using different setups and body locations

  • Armañac-Julián, Pablo
  • Kontaxis, Spyridon
  • Rapalis, Andrius
  • Marozas, Vaidotas
  • Laguna, Pablo
  • Bailón, Raquel
  • Gil, Eduardo
  • Lázaro, Jesús
Pulse photoplethysmography (PPG) is a simple and economical technique for obtaining cardiovascular information. In fact, PPG has become a very popular technology among wearable devices. However, the PPG signal is well-known to be very vulnerable to artifacts, and a good quality signal cannot be expected for most of the time in daily life. The percentage of time that a given measurement can be estimated (e.g., pulse rate) is denoted coverage (C), and it is highly dependent on the subject activity and on the configuration of the sensor, location, and stability of contact. This work aims to quantify the coverage of PPG sensors, using the simultaneously recorded electrocardiogram as a reference, with the PPG recorded at different places in the body and under different stress conditions. While many previous works analyzed the feasibility of PPG as a surrogate for heart rate variability analysis, there exists no previous work studying coverage to derive other cardiovascular indices. We report the coverage not only for estimating pulse rate (PR) but also for estimating pulse arrival time (PAT) and pulse amplitude variability (PAV). Three different datasets are analyzed for this purpose, consisting of a tilt-table test, an acute emotional stress test, and a heat stress test. The datasets include 19, 120, and 51 subjects, respectively, with PPG at the finger and at the forehead for the first two datasets and at the earlobe, in addition, for the latter. C ranges from 70% to 90% for estimating PR. Regarding the estimation of PAT, C ranges from 50% to 90%, and this is very dependent on the PPG sensor location, PPG quality, and the fiducial point (FP) chosen for the delineation of PPG. In fact, the delineation of the FP is critical in time for estimating derived series such as PAT due to the small dynamic range of these series. For the estimation of PAV, the C rates are between 70% and 90%. In general, lower C rates have been obtained for the PPG at the forehead. No difference in C has been observed between using PPG at the finger or at the earlobe. Then, the benefits of using either will depend on the application. However, different C rates are obtained using the same PPG signal, depending on the FP chosen for delineation. Lower C is reported when using the apex point of the PPG instead of the maximum flow velocity or the basal point, with a difference from 1% to even 10%. For further studies, each setup should first be analyzed and validated, taking the results and guidelines presented in this work into account, to study the feasibility of its recording devices with respect to each specific application.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Effects of sedatives and opioids on trigger and cycling asynchronies throughout mechanical ventilation, An observational study in a large dataset from critically ill patients

  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Magrans, Rudys
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Montanyà, Jaume
  • Lena, Enrico
  • Subirà, Carles|||0000-0003-2285-2311
  • Fernández-Gonzalo, Sol|||0000-0003-0267-0617
  • Gomà, Gemma|||0000-0002-1890-4855
  • Fernández, Rafael
  • Albaiceta, Guillermo M.|||0000-0002-9276-3253
  • Skrobik, Yoanna|||0000-0002-5315-6020
  • Lucangelo, Umberto
  • Murias, Gastón
  • Ochagavía Calvo, Ana|||0000-0002-0564-2913
  • Kacmarek, Robert M.
  • Rué, Montserrat|||0000-0002-7862-9365
  • Blanch, Lluís|||0000-0002-4158-7464
Background: In critically ill patients, poor patient-ventilator interaction may worsen outcomes. Although sedatives are often administered to improve comfort and facilitate ventilation, they can be deleterious. Whether opioids improve asynchronies with fewer negative effects is unknown. We hypothesized that opioids alone would improve asynchronies and result in more wakeful patients than sedatives alone or sedatives-plus-opioids. Methods: This prospective multicenter observational trial enrolled critically ill adults mechanically ventilated (MV).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Patient-ventilator asynchronies during mechanical ventilation, current knowledge and research priorities

  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Ochagavía Calvo, Ana|||0000-0002-0564-2913
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Fernández-Gonzalo, Sol|||0000-0003-0267-0617
  • Navarra-Ventura, Guillem|||0000-0001-9839-7357
  • Magrans, Rudys
  • Montanyà, Jaume
  • Blanch, Lluís|||0000-0002-4158-7464
Mechanical ventilation is common in critically ill patients. This life-saving treatment can cause complications and is also associated with long-term sequelae. Patient-ventilator asynchronies are frequent but underdiagnosed, and they have been associated with worse outcomes. Asynchronies occur when ventilator assistance does not match the patient's demand. Ventilatory overassistance or underassistance translates to different types of asynchronies with different effects on patients. Underassistance can result in an excessive load on respiratory muscles, air hunger, or lung injury due to excessive tidal volumes. Overassistance can result in lower patient inspiratory drive and can lead to reverse triggering, which can also worsen lung injury. Identifying the type of asynchrony and its causes is crucial for effective treatment. Mechanical ventilation and asynchronies can affect hemodynamics. An increase in intrathoracic pressure during ventilation modifies ventricular preload and afterload of ventricles, thereby affecting cardiac output and hemodynamic status. Ineffective efforts can decrease intrathoracic pressure, but double cycling can increase it. Thus, asynchronies can lower the predictive accuracy of some hemodynamic parameters of fluid responsiveness. New research is also exploring the psychological effects of asynchronies. Anxiety and depression are common in survivors of critical illness long after discharge. Patients on mechanical ventilation feel anxiety, fear, agony, and insecurity, which can worsen in the presence of asynchronies. Asynchronies have been associated with worse overall prognosis, but the direct causal relation between poor patient-ventilator interaction and worse outcomes has yet to be clearly demonstrated. Critical care patients generate huge volumes of data that are vastly underexploited. New monitoring systems can analyze waveforms together with other inputs, helping us to detect, analyze, and even predict asynchronies. Big data approaches promise to help us understand asynchronies better and improve their diagnosis and management. Although our understanding of asynchronies has increased in recent years, many questions remain to be answered. Evolving concepts in asynchronies, lung crosstalk with other organs, and the difficulties of data management make more efforts necessary in this field.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Cognitive phenotypes 1 month after ICU discharge in mechanically ventilated patients, a prospective observational cohort study

  • Fernández-Gonzalo, Sol|||0000-0003-0267-0617
  • Navarra-Ventura, Guillem|||0000-0001-9839-7357
  • Bacardit, Neus
  • Gomà, Gemma|||0000-0002-1890-4855
  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Subirà, Carles|||0000-0003-2285-2311
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Magrans, Rudys
  • Sarlabous, Leonardo|||0000-0002-0495-8422
  • Aquino Esperanza, Jose
  • Jódar Vicente, Mercè|||0000-0002-8913-5977
  • Rué, Montserrat|||0000-0002-7862-9365
  • Ochagavía Calvo, Ana|||0000-0002-0564-2913
  • Palao, Diego|||0000-0002-3323-6568
  • Fernández, Rafael
  • Blanch, Lluís|||0000-0002-4158-7464
ICU patients undergoing invasive mechanical ventilation experience cognitive decline associated with their critical illness and its management. The early detection of different cognitive phenotypes might reveal the involvement of diverse pathophysiological mechanisms and help to clarify the role of the precipitating and predisposing factors. Our main objective is to identify cognitive phenotypes in critically ill survivors 1 month after ICU discharge using an unsupervised machine learning method, and to contrast them with the classical approach of cognitive impairment assessment. For descriptive purposes, precipitating and predisposing factors for cognitive impairment were explored. A total of 156 mechanically ventilated critically ill patients from two medical/surgical ICUs were prospectively studied. Patients with previous cognitive impairment, neurological or psychiatric diagnosis were excluded. Clinical variables were registered during ICU stay, and 100 patients were cognitively assessed 1 month after ICU discharge. The unsupervised machine learning K-means clustering algorithm was applied to detect cognitive phenotypes. Exploratory analyses were used to study precipitating and predisposing factors for cognitive impairment. K-means testing identified three clusters (K) of patients with different cognitive phenotypes: K1 (n = 13), severe cognitive impairment in speed of processing (92%) and executive function (85%); K2 (n = 33), moderate-to-severe deficits in learning-memory (55%), memory retrieval (67%), speed of processing (36.4%) and executive function (33.3%); and K3 (n = 46), normal cognitive profile in 89% of patients. Using the classical approach, moderate-to-severe cognitive decline was recorded in 47% of patients, while the K-means method accurately classified 85.9%. The descriptive analysis showed significant differences in days (p = 0.016) and doses (p = 0.039) with opioid treatment in K1 vs. K2 and K3. In K2, there were more women, patients were older and had more comorbidities (p = 0.001) than in K1 or K3. Cognitive reserve was significantly (p = 0.001) higher in K3 than in K1 or K2. One month after ICU discharge, three groups of patients with different cognitive phenotypes were identified through an unsupervised machine learning method. This novel approach improved the classical classification of cognitive impairment in ICU survivors. In the exploratory analysis, gender, age and the level of cognitive reserve emerged as relevant predisposing factors for cognitive impairment in ICU patients. ClinicalTrials.gov Identifier:NCT02390024; March 17,2015.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Cardiopulmonary coupling indices to assess weaning readiness from mechanical ventilation

  • Armañac-Julián, Pablo
  • Hernando, David|||0000-0002-1462-4880
  • Lázaro, Jesús
  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Magrans, Rudys
  • Morales, John
  • Moeyersons, Jonathan
  • Sarlabous, Leonardo|||0000-0002-0495-8422
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Subirà, Carles|||0000-0003-2285-2311
  • Fernández, Rafael
  • Orini, Michele
  • Laguna, Pablo|||0000-0003-3434-9254
  • Varon, Carolina|||0000-0002-9581-0676
  • Gil, Eduardo
  • Bailón, Raquel|||0000-0003-1272-0550
  • Blanch, Lluís|||0000-0002-4158-7464
The ideal moment to withdraw respiratory supply of patients under Mechanical Ventilation at Intensive Care Units (ICU), is not easy to be determined for clinicians. Although the Spontaneous Breathing Trial (SBT) provides a measure of the patients' readiness, there is still around 15-20% of predictive failure rate. This work is a proof of concept focused on adding new value to the prediction of the weaning outcome. Heart Rate Variability (HRV) and Cardiopulmonary Coupling (CPC) methods are evaluated as new complementary estimates to assess weaning readiness. The CPC is related to how the mechanisms regulating respiration and cardiac pumping are working simultaneously, and it is defined from HRV in combination with respiratory information. Three different techniques are used to estimate the CPC, including Time-Frequency Coherence, Dynamic Mutual Information and Orthogonal Subspace Projections. The cohort study includes 22 patients in pressure support ventilation, ready to undergo the SBT, analysed in the 24 h previous to the SBT. Of these, 13 had a successful weaning and 9 failed the SBT or needed reintubation -being both considered as failed weaning. Results illustrate that traditional variables such as heart rate, respiratory frequency, and the parameters derived from HRV do not differ in patients with successful or failed weaning. Results revealed that HRV parameters can vary considerably depending on the time at which they are measured. This fact could be attributed to circadian rhythms, having a strong influence on HRV values. On the contrary, significant statistical differences are found in the proposed CPC parameters when comparing the values of the two groups, and throughout the whole recordings. In addition, differences are greater at night, probably because patients with failed weaning might be experiencing more respiratory episodes, e.g. apneas during the night, which is directly related to a reduced respiratory sinus arrhythmia. Therefore, results suggest that the traditional measures could be used in combination with the proposed CPC biomarkers to improve weaning readiness.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

The Effect of Clusters of Double Triggering and Ineffective Efforts in Critically Ill Patients

  • Magrans, Rudys
  • Ferreira, Francini
  • Sarlabous, Leonardo|||0000-0002-0495-8422
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Gomà, Gemma|||0000-0002-1890-4855
  • Fernández-Gonzalo, Sol|||0000-0003-0267-0617
  • Navarra-Ventura, Guillem|||0000-0001-9839-7357
  • Fernández, Rafael
  • Montanyà, Jaume
  • Kacmarek, Robert
  • Rué, Montserrat|||0000-0002-7862-9365
  • Forne, Carles|||0000-0002-8133-3274
  • Blanch, Lluís|||0000-0002-4158-7464
  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Aquino Esperanza, Jose
OBJECTIVES: To characterize clusters of double triggering and ineffective inspiratory efforts throughout mechanical ventilation and investigate their associations with mortality and duration of ICU stay and mechanical ventilation. DESIGN: Registry-based, real-world study. Background: Asynchronies during invasive mechanical ventilation can occur as isolated events or in clusters and might be related to clinical outcomes. Subjects: Adults requiring mechanical ventilation greater than 24 hours for whom greater than or equal to 70% of ventilator waveforms were available. INTERVENTIONS: We identified clusters of double triggering and ineffective inspiratory efforts and determined their power and duration. We used Fine-Gray's competing risk model to analyze their effects on mortality and generalized linear models to analyze their effects on duration of mechanical ventilation and ICU stay. MEASUREMENTS AND MAIN RESULTS: We analyzed 58,625,796 breaths from 180 patients. All patients had clusters (mean/d, 8.2 [5.4-10.6]; mean power, 54.5 [29.6-111.4]; mean duration, 20.3 min [12.2-34.9 min]). Clusters were less frequent during the first 48 hours (5.5 [2.5-10] vs 7.6 [4.4-9.9] in the remaining period [p = 0.027]). Total number of clusters/d was positively associated with the probability of being discharged alive considering the total period of mechanical ventilation (p = 0.001). Power and duration were similar in the two periods. Power was associated with the probability of being discharged dead (p = 0.03), longer mechanical ventilation (p < 0.001), and longer ICU stay (p = 0.035); cluster duration was associated with longer ICU stay (p = 0.027). CONCLUSIONS: Clusters of double triggering and ineffective inspiratory efforts are common. Although higher numbers of clusters might indicate better chances of survival, clusters with greater power and duration indicate a risk of worse clinical outcomes.