Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 47
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Validation of the apple watch for heart rate variability measurements during relax and mental stress in healthy subjects

  • Hernando, D.
  • Roca, S.
  • Sancho, J.
  • Alesanco, Á.
  • Bailón, R.
Heart rate variability (HRV) analysis is a noninvasive tool widely used to assess autonomic nervous system state. The market for wearable devices that measure the heart rate has grown exponentially, as well as their potential use for healthcare and wellbeing applications. Still, there is a lack of validation of these devices. In particular, this work aims to validate the Apple Watch in terms of HRV derived from the RR interval series provided by the device, both in temporal (HRM (mean heart rate), SDNN, RMSSD and pNN50) and frequency (low and high frequency powers, LF and HF) domain. For this purpose, a database of 20 healthy volunteers subjected to relax and a mild cognitive stress was used. First, RR interval series provided by Apple Watch were validated using as reference the RR interval series provided by a Polar H7 using Bland-Altman plots and reliability and agreement coefficients. Then, HRV parameters derived from both RR interval series were compared and their ability to identify autonomic nervous system (ANS) response to mild cognitive stress was studied. Apple Watch measurements presented very good reliability and agreement (>0.9). RR interval series provided by Apple Watch contain gaps due to missing RR interval values (on average, 5 gaps per recording, lasting 6.5 s per gap). Temporal HRV indices were not significantly affected by the gaps. However, they produced a significant decrease in the LF and HF power. Despite these differences, HRV indices derived from the Apple Watch RR interval series were able to reflect changes induced by a mild mental stress, showing a significant decrease of HF power as well as RMSSD in stress with respect to relax, suggesting the potential use of HRV measurements derived from Apple Watch for stress monitoring.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A response surface optimization approach to adjust ionic current conductances of cardiac electrophysiological models. Application to the study of potassium level changes

  • Carro, J.
  • Pueyo, E.
  • Rodriguez Matas, J.F.
Cardiac electrophysiological computational models are often developed from previously published models. The new models may incorporate additional features to adapt the model to a different species or may upgrade a specific ionic formulation based on newly available experimental data. A relevant challenge in the development of a new model is the estimation of certain ionic current conductances that cannot be reliably identified from experiments. A common strategy to estimate those conductances is by means of constrained non-linear least-squares optimization. In this work, a novel methodology is proposed for estimation of ionic current conductances of cardiac electrophysiological models by using a response surface approximation-based constrained optimization with trust region management. Polynomial response surfaces of a number of electrophysiological markers were built using statistical sampling methods. These markers included action potential duration (APD), triangulation, diastolic and systolic intracellular calcium concentration, and time constants of APD rate adaptation. The proposed methodology was applied to update the Carro et al. human ventricular action potential model after incorporation of intracellular potassium ([K+]i) dynamics. While the Carro et al. model was well suited for investigation of arrhythmogenesis, it did not allow simulation of [K+]i changes. With the methodology proposed in this study, the updated Carro et al. human ventricular model could be used to simulate [K+]i changes in response to varying extracellular potassium ([K+]o) levels. Additionally, it rendered values of evaluated electrophysiological markers within physiologically plausible ranges. The optimal values of ionic current conductances in the updated model were found in a notably shorter time than with previously proposed methodologies. As a conclusion, the response surface optimization-based approach proposed in this study allows estimating ionic current conductances of cardiac electrophysiological computational models while guaranteeing replication of key electrophysiological features and with an important reduction in computational cost with respect to previously published approaches. The updated Carro et al. model developed in this study is thus suitable for the investigation of arrhythmic risk-related conditions, including those involving large changes in potassium concentration.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Otros (Other)

Editorial: Safety Pharmacology - Risk Assessment QT Interval Prolongation and Beyond

  • Grandi, E.
  • Morotti, S.
  • Pueyo, E.
  • Rodriguez, B.
The scope of safety pharmacology is to predict whether a drug is likely to cause potentially lethal adverse effects if administered to humans. While safety pharmacology has broadened its interests in recent years to the whole cardiovascular, respiratory, and central nervous systems (and is now extending to other body functions), a major focus since its inception has been assessing drug-induced prolongation in the QT interval—a surrogate biomarker for torsades de pointes (TdP) liability. Because the vast majority of drugs that can cause QT prolongation inhibit hERG channels, current regulatory guidelines concerning cardiac safety recommend that all compounds are evaluated in vitro for their hERG inhibitory potency (Redfern et al., 2003) and in vivo for their ability to cause QT/QTc interval prolongation (Food and Drug Administration, 2005) in an appropriate animal model and in humans. However, it has now become apparent that QT/QTc prolongation and hERG block are an insufficient proxy for TdP risk. While the current approach based on these markers has been successful in terms of preventing TdP risk, this regulatory paradigm might lead to withdrawal from the drug development pipeline and clinical use of potentially safe drugs. There is therefore a crucial need to develop a more accurate assessment of proarrhythmic potential of drugs...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

KCa3.1 Transgene Induction in Murine Intestinal Epithelium Causes Duodenal Chyme Accumulation and Impairs Duodenal Contractility.

  • Valero Gracia, Marta Sofía
  • Ramón Gimenez, Mariano
  • Lozano-Gerona, Javier
  • Delgado-Wicke, Pablo
  • Calmarza, Pilar
  • Olivan-Viguera, Aida
  • López, Víctor
  • García-Otín, Luís-Ángel
  • Valero, Salvador
  • Pueyo, Esther
  • Hamilton, Kir
  • Miura, Hioto
  • Köhler, Ralf
Abstract: The epithelial intermediate-conductance calcium/calmodulin-regulated KCa3.1 channel is considered to be a regulator of intestine function by controlling chloride secretion and water/salt balance. Yet, little is known about the functional importance of KCa3.1 in the intestinal epithelium in vivo. Our objective was to determine the impact of epithelial-specific inducible overexpression of a KCa3.1 transgene (KCa3.1+) and of inducible suppression (KCa3.1-) on intestinal homeostasis and function in mice. KCa3.1 overexpression in the duodenal epithelium of doxycycline (DOX)-treated KCa3.1+ mice was 40-fold above the control levels. Overexpression caused an inflated duodenum and doubling of the chyme content. Histology showed conserved architecture of crypts, villi, and smooth muscle. Unaltered proliferating cell nuclear antigen (PCNA) immune reactivity and reduced amounts of terminal deoxynucleotide transferase mediated X-dUTP nick end labeling (TUNEL)-positive apoptotic cells in villi indicated lower epithelial turnover. Myography showed a reduction in the frequency of spontaneous propulsive muscle contractions with no change in amplitude. The amount of stool in the colon was increased and the frequency of colonic contractions was reduced in KCa3.1+ animals. Senicapoc treatment prevented the phenotype. Suppression of KCa3.1 in DOX-treated KCa3.1- mice caused no overt intestinal phenotype. In conclusion, inducible KCa3.1 overexpression alters intestinal functions by increasing the chyme content and reducing spontaneous contractions and epithelial apoptosis. Induction of epithelial KCa3.1 can play a mechanistic role in the process of adaptation of the intestine.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Automatic diagnosis of strict left bundle branch block using a wavelet-based approach

  • Martín-Yebra, A.
  • Martínez, J.P.
Patients with left bundle branch block (LBBB) are known to have a good clinical response to cardiac resynchronization therapy. However, the high number of false positive diagnosis obtained with the conventional LBBB criteria limits the effectiveness of this therapy, which has yielded to the definition of new stricter criteria. They require prolonged QRS duration, a QS or rS pattern in the QRS complexes at leads V1 and V2 and the presence of mid-QRS notch/slurs in 2 leads within V1, V2, V5, V6, I and aVL. The aim of this work was to develop and assess a fully-automatic algorithm for strict LBBB diagnosis based on the wavelet transform. Twelve-lead, high-resolution, 10-second ECGs from 602 patients enrolled in the MADIT-CRT trial were available. Data were labelled for strict LBBB by 2 independent experts and divided into training (n = 300) and validation sets (n = 302) for assessing algorithm performance. After QRS detection, a wavelet-based delineator was used to detect individual QRS waves (Q, R, S), QRS onsets and ends, and to identify the morphological QRS pattern on each standard lead. Then, multilead QRS boundaries were defined in order to compute the global QRS duration. Finally, an automatic algorithm for notch/slur detection within the QRS complex was applied based on the same wavelet approach used for delineation. In the validation set, LBBB was diagnosed with a sensitivity and specificity of Se = 92.9% and Sp = 65.1% (Acc = 79.5%, PPV = 74% and NPV = 89.6%). The results confirmed that diagnosis of strict LBBB can be done based on a fully automatic extraction of temporal and morphological QRS features. However, it became evident that consensus in the definition of QRS duration as well as notch and slurs definitions is necessary in order to guarantee accurate and repeatable diagnosis of complete LBBB.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Baroreflex sensitivity measured by pulse photoplethysmography

  • Lázaro, Jesús
  • Gil, Eduardo
  • Orini, Michele
  • Laguna, Pablo
  • Bailón, Raquel
Novel methods for assessing baroreflex sensitivity (BRS) using only pulse photoplethysmography (PPG) signals are presented. Proposed methods were evaluated with a data set containing electrocardiogram (ECG), blood pressure (BP), and PPG signals from 17 healthy subjects during a tilt table test. The methods are based on a surrogate of a index, which is defined as the power ratio of RR interval variability (RRV) and that of systolic arterial pressure series variability (SAPV). The proposed a index surrogates use pulse-to-pulse interval series variability (PPV) as a surrogate of RRV, and different morphological features of the PPG pulse which have been hypothesized to be related to BP, as series surrogates of SAPV. A time-frequency technique was used to assess BRS, taking into account the non-stationarity of the protocol. This technique identifies two time-varying frequency bands where RRV and SAPV (or their surrogates) are expected to be coupled: the low frequency (LF, inside 0.04–0.15 Hz range), and the high frequency (HF, inside 0.15–0.4 Hz range) bands. Furthermore, time-frequency coherence is used to identify the time intervals when the RRV and SAPV (or their surrogates) are coupled. Conventional a index based on RRV and SAPV was used as Gold Standard. Spearman correlation coefficients between conventional a index and its PPG-based surrogates were computed and the paired Wilcoxon statistical test was applied in order to assess whether the indices can find significant differences (p < 0.05) between different stages of the protocol. The highest correlations with the conventional a index were obtained by the a-index-surrogate based on PPV and pulse up-slope (PUS), with 0.74 for LF band, and 0.81 for HF band. Furthermore, this index found significant differences between rest stages and tilt stage in both LF and HF bands according to the paired Wilcoxon test, as the conventional a index also did. These results suggest that BRS changes induced by the tilt test can be assessed with high correlation by only a PPG signal using PPV as RRV surrogate, and PPG morphological features as SAPV surrogates, being PUS the most convenient SAPV surrogate among the studied ones.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Quantification of Ventricular Repolarization Variation for Sudden Cardiac Death Risk Stratification in Atrial Fibrillation

  • Martín Yebra, Alba
  • Laguna, Pablo
  • Cygankiewicz, Iwona
  • Bayés-de-Luna, Antoni
  • Caiani, Enrico G.
  • Martínez, Juan Pablo
Objective: Atrial fibrillation (AF) rhythm gives rise to an irregular response in ventricular activity, preventing the use of standard ECG-derived risk markers based on ventricular repolarization heterogeneity under this particular condition. In this study we proposed new indices to quantify repolarization variations in AF patients, assessing their stratification performance in a chronic heart failure (CHF) population with AF. Methods: We developed a method based on a selective bin averaging technique. Consecutive beats preceded by a similar RR interval were selected, from which the average variation within the ST-T complex for each RR range was computed.We proposed two sets of indices: (i) the 2-beat index of ventricular repolarization variation, (I_V2), computed from pairs of stable consecutive beats; and (ii) the 3-beat indices of ventricular repolarization variation, computed in triplets of stable consecutive beats (I_V3). Results: These indices showed a significant association with sudden cardiac death (SCD) outcome in the study population. In addition, risk assessment based on the combination of the proposed indices improved stratification performance compared to their individual potential. Conclusion: Patients with enhanced ventricular repolarization variation computed in terms of the proposed indices were successfully associated to a higher SCD incidence in our study population, evidencing their prognostic value. Significance: using a simple ambulatory ECG recording, it is possible to stratify AF patients at risk of SCD, which may help cardiologists in adopting most effective therapeutic strategies, with a positive impact in both the patient and healthcare systems.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic dysfunction increases cardiovascular risk in the presence of sleep apnea

  • Milagro, Javier
  • Deviaene, Margot
  • Gil, Eduardo
  • Lazaro, Jesús
  • Buyse, Bertien
  • Testelmans, Dries
  • Borzée, Pascal
  • Willems, Rik
  • Van Huffel, Sabine
  • Bailón, Raquel
  • Varon, Carolina
The high prevalence of sleep apnea syndrome (SAS) and its direct relationship with an augmented risk of cardiovascular disease (CVD) have raised SAS as a primary public health problem. For this reason, extensive research aiming to understand the interaction between both conditions has been conducted. The advances in non-invasive autonomic nervous system (ANS) monitoring through heart rate variability (HRV) analysis have revealed an increased sympathetic dominance in subjects suffering from SAS when compared with controls. Similarly, HRV analysis of subjects with CVD suggests altered autonomic activity. In this work, we investigated the altered autonomic control in subjects suffering from SAS and CVD simultaneously when compared with SAS patients, as well as the possibility that ANS assessment may be useful for the early stage identification of cardiovascular risk in subjects with SAS. The analysis was performed over 199 subjects from two independent datasets during night-time, and the effects of the physiological response following an apneic episode, sleep stages, and respiration on HRV were taken into account. Results, as measured by HRV, suggest a decreased sympathetic dominance in those subjects suffering from both conditions, as well as in subjects with SAS that will develop CVDs, which was reflected in a significantly reduced sympathovagal balance (p < 0.05). In this way, ANS monitoring could contribute to improve screening and diagnosis, and eventually aid in the phenotyping of patients, as an altered response might have direct implications on cardiovascular health.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Electrocardiogram-derived tidal volume during treadmill stress test

  • Milagro, Javier
  • Hernando, David
  • Lázaro, Jesús
  • Casajús, Jose Antonio
  • Garatachea, Nuria
  • Gil, Eduardo
  • Bailón, Raquel
Objective: Electrocardiogram (ECG) has been regarded as a source of respiratory information with the main focus in the estimation of the respiratory rate. Although little research concerning the estimation of tidal volume (TV) has been conducted, there are several ECG-derived features that have been related with TV in the literature, such as ECG-derived respiration, heart rate variability or respiratory rate. In this work, we exploited these features for estimating TV using a linear model. Methods: 25 young (33.4 ± 5.2 years) healthy male volunteers were recruited for performing a maximal (MaxT) and a submaximal (SubT) treadmill stress test, which were conducted in different days. Both tests were automatically segmented in stages attending to the heart rate. Afterwards, a subject-specific TV model was calibrated for each stage, employing features from MaxT, and the model was later used for estimating the TV in SubT. Results: During exercise, the different proposed approaches led to relative fitting errors lower than 14% in most of the cases and than 6% in some of them. Conclusion: Low achieved fitting errors suggest that TV can be estimated from ECG during a treadmill stress test. Significance: The results suggest that it is possible to estimate TV during exercise using only ECG-derived features.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic Waveform Versus Heart Rate Variability to Identify Low Stress States. Attention Test

  • Peláez Coca, María Dolores
  • Lozano Albalate, María Teresa
  • Hernando Sanz, Alberto
  • Aiger Vallés, Montserrat
  • Gil, Eduardo
Our long-term goal is the development of an automatic identifier of attentional states. In order to accomplish it, we should firstly be able to identify different states based on physiological signals. So, the first aim of this work is to identify the most appropriate features, to detect a subject high performance state. For that, a database of electrocardiographic (ECG) and photopletysmographic (PPG) signals is recorded in two unequivocally defined states (rest and attention task) from up to 50 subjects as a sample of the population. Time and frequency parameters of heart/pulse rate variability have been computed from the ECG/PPG signals respectively. Additionally, the respiratory rate has been estimated from both signals and also six morphological parameters from PPG. In total, twenty six features are obtained for each subject. They provide information about the autonomic nervous system and the physiological response of the subject to an attention demand task. Results show an increase of sympathetic activation when the subjects perform the attention test. The amplitude and width of the PPG pulse were more sensitive that the classical sympathetic markers (normalised power in LF and LF/HF ratio) for identifying this attentional state. State classification accuracy reaches a mean of 89 $\pm$ 2%, a maximum of 93% and a minimum of 85%, in the hundred classifications made by only selecting four parameters extracted from the PPG signal (pulse amplitude, pulse width, pulse downward slope and mean pulse rate). These results suggest that attentional states could be identified by PPG.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG-derived respiratory rate in atrial fibrillation

  • Kontaxis, Spyridon
  • Lázaro Plaza, Jesús
  • Corino, Valentina
  • Sandberg, Frida
  • Bailón Luesma, Raquel
  • Laguna Lasaosa, Pablo
  • Sörnmo, Leif
Objective: The present study addresses the problem of estimating the respiratory rate from the morphological ECG variations in the presence of atrial fibrillatory waves (f-waves). The significance of performing f-wave suppression before respiratory rate estimation is investigated. Methods: The performance of a novel approach to ECG-derived respiration, named “slope range” (SR) and designed particularly for operation in atrial fibrillation (AF), is compared to that of two well-known methods based on either R-wave angle (RA) or QRS loop rotation angle (LA). A novel rule is proposed for spectral peak selection in respiratory rate estimation. The suppression of f-waves is accomplished using signal- and noise-dependent QRS weighted averaging. The performance evaluation embraces real as well as simulated ECG signals acquired from patients with persistent AF; the estimation error of the respiratory rate is determined for both types of signals. Results: Using real ECG signals and reference respiratory signals, rate estimation without f-wave suppression resulted in a median error of 0.015±0.021 Hz and 0.019±0.025 Hz for SR and RA, respectively, whereas LA with f-wave suppression resulted in 0.034±0.039 Hz. Using simulated signals, the results also demonstrate that f-wave suppression is superfluous for SR and RA, whereas it is essential for LA. Conclusion: The results show that SR offers the best performance as well as computational simplicity since f-wave suppression is not needed. Significance: The respiratory rate can be robustly estimated from the ECG in the presence of AF.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Finger and forehead PPG signal comparison for respiratory rate estimation

  • Hernando, Alberto
  • Peláez-Coca, María Dolores
  • Lozano, María Teresa
  • Lázaro, Jesús
  • Gil, Eduardo
Objective: an evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. Approach: finger-PPG, forehead-PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability (PWV), pulse amplitude variability (PAV) and the respiratory- induced intensity variability (RIIV). Respiratory rate was estimated from each one of the 4 PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. Main results: results show a better performance in terms of successful estimation and relative error when: i) PPG signal is recorded in the finger; ii) the respiratory rate is less than 0.4 Hz; iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. Significance: these results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that finger is better than forehead to estimate respiratory rate.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optimal fiducial points for pulse rate variability analysis from forehead and finger PPG signals

  • Peralta Calvo, Elena
  • Lázaro Plaza, Jesús
  • Bailón Luesma, Raquel
  • Marozas, Vaidotas
  • Gil Herrando, Eduardo
Objective: The aim of this work is to evaluate and compare five fiducialpoints for the temporal location of each pulse wave from forehead and fingerphotoplethysmographic pulse waves signals (PPG) to perform pulse rate variability(PRV) analysis as a surrogate of heart rate variability (HRV) analysis. Approach: Forehead and finger PPG signals were recorded during tilt-table testsimultaneously to the ECG. Artifacts were detected and removed and, five fiducialpoints were computed: apex, middle-amplitude and foot points of the PPG signal,apex point of the first derivative signal and, the intersection point of the tangent tothe PPG waveform at the apex of the derivative PPG signal and the tangent to thefoot of the PPG pulse defined as intersecting tangents method. Pulse period (PP)time intervals series were obtained from both PPG signals and compared to the RRintervals obtained from the ECG. Heart and pulse rate variability signals (HRV andPRV) were estimated and, classical time and frequency domain indices were computed. Main Results: The middle-amplitude point of the PPG signal (nM), the apexpoint of the first derivative (n*A), and the tangents intersection point (nT) are themost suitable fiducial points for PRV analysis, which result in the lowest relativeerrors estimated between PRV and HRV indices, higher correlation coefficients and reliability indexes. Statistically significant differences according to the Wilcoxon testbetween PRV and HRV signals were found for the apex and foot fiducial points ofthe PPG, as well as the lowest agreement between RR and PP series according toBland-Altman analysis. Hence, they have been considered less accurate for variabilityanalysis. In addition, the relative errors are significantly lower fornMandn*Afeaturesby using Friedman statistics with Bonferroni multiple-comparison test and, we proposenMas the most accurate fiducial point. Based on our results, forehead PPG seems toprovide more reliable information for a PRV assessment than finger PPG. Significance: The accuracy of the pulse wave detections depends on the morphologyof the PPG. There is therefore a need to widely define the most accurate fiducial pointto perform a PRV analysis under non-stationary conditions based on different PPGsensor locations and signal acquisition techniques.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The Effect of Emotional Valence on Ventricular Repolarization Dynamics Is Mediated by Heart Rate Variability: A Study of QT Variability and Music-Induced Emotions

  • Orini, Michele
  • Al-Amodi, Faez
  • Koelsch, Stefan
  • Bailón, Raquel
Background: Emotions can affect cardiac activity, but their impact on ventricular repolarization variability, an important parameter providing information about cardiac risk and autonomic nervous system activity, is unknown. The beat-to-beat variability of the QT interval (QTV) from the body surface ECG is a non-invasive marker of repolarization variability, which can be decomposed into QTV related to RR variability (QTVrRRV) and QTV unrelated to RRV (QTVuRRV), with the latter thought to be a marker of intrinsic repolarization variability. Aim: To determine the effect of emotional valence (pleasant and unpleasant) on repolarization variability in healthy volunteers by means of QTV analysis. Methods: 75 individuals (24.5 ± 3.2 years, 36 females) without a history of cardiovascular disease listened to music-excerpts that were either felt as pleasant (n = 6) or unpleasant (n = 6). Excerpts lasted about 90 s and were presented in a random order along with silent intervals (n = 6). QTV and RRV were derived from the ECG and the time-frequency spectrum of RRV, QTV, QTVuRRV and QTVrRRV as well as time-frequency coherence between QTV and RRV were estimated. Analysis was performed in low-frequency (LF), high frequency (HF) and total spectral bands. Results: The heart rate-corrected QTV showed a small but significant increase from silence (median 347/interquartile range 31 ms) to listening to music felt as unpleasant (351/30 ms) and pleasant (355/32 ms). The dynamic response of QTV to emotional valence showed a transient phase lasting about 20 s after the onset of each musical excerpt. QTV and RRV were highly correlated in both HF and LF (mean coherence ranging 0.76–0.85). QTV and QTVrRRV decreased during listening to music felt as pleasant and unpleasant with respect to silence and further decreased during listening to music felt as pleasant. QTVuRRV was small and not affected by emotional valence. Conclusion: Emotional valence, as evoked by music, has a small but significant effect on QTV and QTVrRRV, but not on QTVuRRV. This suggests that the interaction between emotional valence and ventricular repolarization variability is mediated by cycle length dynamics and not due to intrinsic repolarization variability.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Long-term microgravity exposure increases ECG repolarization instability manifested by low-frequency oscillations of T-Wave vector

  • Palacios, Saúl
  • Caiani, Enrico G.
  • Landreani, Federica
  • Martínez, Juan Pablo
  • Pueyo, Esther
Ventricular arrhythmias and sudden cardiac death during long-term space missions are a major concern for space agencies. Long-duration spaceflight and its ground-based analog head-down bed rest (HDBR) have been reported to markedly alter autonomic and cardiac functioning, particularly affecting ventricular repolarization of the electrocardiogram (ECG). In this study, novel methods are developed, departing from previously published methodologies, to quantify the index of Periodic Repolarization Dynamics (PRD), an arrhythmic risk marker that characterizes sympathetically-mediated low-frequency oscillations in the T-wave vector. PRD is evaluated in ECGs from 42 volunteers at rest and during an orthostatic tilt table test recorded before and after 60-day –6° HDBR. Our results indicate that tilt test, on top of enhancing sympathetic regulation of heart rate, notably increases PRD, both before and after HDBR, thus supporting previous evidence on PRD being an indicator of sympathetic modulation of ventricular repolarization. Importantly, long-term microgravity exposure is shown to lead to significant increases in PRD, both when evaluated at rest and, even more notably, in response to tilt test. The extent of microgravity-induced changes in PRD has been associated with arrhythmic risk in prior studies. An exercise-based, but not a nutrition-based, countermeasure is able to partially reverse microgravity-induced effects on PRD. In conclusion, long-term exposure to microgravity conditions leads to elevated low-frequency oscillations of ventricular repolarization, which are potentiated following sympathetic stimulation and are related to increased risk for repolarization instabilities and arrhythmias. Tested countermeasures are only partially effective in counteracting microgravity effects.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Reperfusion Arrhythmias Increase after Superior Cervical Ganglionectomy Due to Conduction Disorders and Changes in Repolarization

  • Prado, Natalia J.
  • Muñoz, Estela M.
  • Farias Altamirano, Luz E.
  • Aguiar, Francisco
  • Ponce Zumino, Amira Z.
  • Sánchez, Francisco J.
  • Miatello, Roberto M.
  • Pueyo, Esther
  • Diez, Emiliano Raúl
Pharmacological concentrations of melatonin reduce reperfusion arrhythmias, but less is known about the antiarrhythmic protection of the physiological circadian rhythm of melatonin. Bilateral surgical removal of the superior cervical ganglia irreversibly suppresses melatonin rhythmicity. This study aimed to analyze the cardiac electrophysiological effects of the loss of melatonin circadian oscillation and the role played by myocardial melatonin membrane receptors, SERCA2A, TNFa, nitrotyrosine, TGFß, KATP channels, and connexin 43. Three weeks after bilateral removal of the superior cervical ganglia or sham surgery, the hearts were isolated and submitted to ten minutes of regional ischemia followed by ten minutes of reperfusion. Arrhythmias, mainly ventricular tachycardia, increased during reperfusion in the ganglionectomy group. These hearts also suffered an epicardial electrical activation delay that increased during ischemia, action potential alternants, triggered activity, and dispersion of action potential duration. Hearts from ganglionectomized rats showed a reduction of the cardioprotective MT2 receptors, the MT1 receptors, and SERCA2A. Markers of nitroxidative stress (nitrotyrosine), inflammation (TNFa), and fibrosis (TGFß and vimentin) did not change between groups. Connexin 43 lateralization and the pore-forming subunit (Kir6.1) of KATP channels increased in the experimental group. We conclude that the loss of the circadian rhythm of melatonin predisposes the heart to suffer cardiac arrhythmias, mainly ventricular tachycardia, due to conduction disorders and changes in repolarization.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Conditional KCa3.1-transgene induction in murine skin produces pruritic eczematous dermatitis with severe epidermal hyperplasia and hyperkeratosis

  • Lozano-Gerona, J.
  • Oliván-Viguera, A.
  • Delgado-Wicke, P.
  • Singh, V.
  • Brown, B.M.
  • Tapia-Casellas, E.
  • Pueyo, E.
  • Valero, M.S.
  • Garcia-Otín, Á.L.
  • Giraldo, P.
  • Abarca-Lachen, E.
  • Surra, J.C.
  • Osada, J.
  • Hamilton, K.L.
  • Raychaudhuri, S.P.
  • Marigil, M.
  • Juarranz, Á.
  • Wulff, H.
  • Miura, H.
  • Gilaberte, Y.
  • Köhler, R.
Ion channels have recently attracted attention as potential mediators of skin disease. Here, we explored the consequences of genetically encoded induction of the cell volume-regulating Ca2+-activated KCa3.1 channel (Kcnn4) for murine epidermal homeostasis. Doxycycline-treated mice harboring the KCa3.1+-transgene under the control of the reverse tetracycline-sensitive transactivator (rtTA) showed 800-fold channel overexpression above basal levels in the skin and solid KCa3.1-currents in keratinocytes. This overexpression resulted in epidermal spongiosis, progressive epidermal hyperplasia and hyperkeratosis, itch and ulcers. The condition was accompanied by production of the pro-proliferative and pro-inflammatory cytokines, IL-ß1 (60-fold), IL-6 (33-fold), and TNFa (26-fold) in the skin. Treatment of mice with the KCa3.1-selective blocker, Senicapoc, significantly suppressed spongiosis and hyperplasia, as well as induction of IL-ß1 (-88%) and IL-6 (-90%). In conclusion, KCa3.1-induction in the epidermis caused expression of pro-proliferative cytokines leading to spongiosis, hyperplasia and hyperkeratosis. This skin condition resembles pathological features of eczematous dermatitis and identifies KCa3.1 as a regulator of epidermal homeostasis and spongiosis, and as a potential therapeutic target.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Data-Driven Identification of Stochastic Model Parameters and State Variables: Application to the Study of Cardiac Beat-to-Beat Variability

  • Sampedro-Puente, David Adolfo
  • Fernández-Bes, Jesús
  • Virág, László
  • Varró, András
  • Pueyo, Esther
Enhanced spatiotemporal ventricular repolarization variability has been associated with ventricular arrhythmias and sudden cardiac death, but the involved mechanisms remain elusive. In this paper, a methodology for estimation of parameters and state variables of stochastic human ventricular cell models from input voltage data is proposed for investigation of repolarization variability. Methods: The proposed methodology formulates state-space representations based on developed stochastic cell models and uses the unscented Kalman filter to perform joint parameter and state estimation. Evaluation over synthetic and experimental data is presented. Results: Results on synthetically generated data show the ability of the methodology to: first, filter out measurement noise from action potential (AP) traces; second, identify model parameters and state variables from each of those individual AP traces, thus allowing robust characterization of cell-to-cell variability; and, third, replicate statistical population''s distributions of input AP-based markers, including dynamic markers quantifying beat-to-beat variability. Application onto experimental data demonstrates the ability of the methodology to match input AP traces while concomitantly inferring the characteristics of underlying stochastic cell models. Conclusion: A novel methodology is presented for estimation of parameters and hidden variables of stochastic cardiac computational models, with the advantage of providing a one-to-one match between each individual AP trace and a corresponding set of model characteristics. Significance: The proposed methodology can greatly help in the characterization of temporal (beat-to-beat) and spatial (cell-to-cell) variability in human ventricular repolarization and in ascertaining the corresponding underlying mechanisms, particularly in scenarios with limited available experimental data.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Bifurcations and Slow-Fast Analysis in a Cardiac Cell Model for Investigation of Early Afterdepolarizations

  • Barrio, R.
  • Martinez, M.A.
  • Perez, L.
  • Pueyo, E.
In this study, we teased out the dynamical mechanisms underlying the generation of arrhythmogenic early afterdepolarizations (EADs) in a three-variable model of a mammalian ventricular cell. Based on recently published studies, we consider a 1-fast, 2-slow variable decomposition of the system describing the cellular action potential. We use sweeping techniques, such as the spike-counting method, and bifurcation and continuation methods to identify parametric regions with EADs. We show the existence of isolas of periodic orbits organizing the different EAD patterns and we provide a preliminary classification of our fast-slow decomposition according to the involved dynamical phenomena. This investigation represents a basis for further studies into the organization of EAD patterns in the parameter space and the involved bifurcations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic waveform analysis for autonomic reactivity assessment in depression

  • Kontaxis, Spyridon
  • Gil, Eduardo
  • Marozas, Vaidotas
  • Lázaro, Jesús
  • García, Esther
  • Posadas-de Miguel, Mar
  • Siddi, Sara
  • Bernal, María Luisa
  • Aguiló, Jordi
  • Haro, Josep María
  • de la Cámara, Concepción
  • Laguna, Pablo
  • Bailón, Raquel
Objective: In the present study, a photoplethysmographic (PPG) waveform analysis for assessing differences in autonomic reactivity to mental stress between patients with Major Depressive Disorder (MDD) and healthy control (HC) subjects is presented. Methods: PPG recordings of 40 MDD and 40 HC subjects were acquired at basal conditions, during the execution of cognitive tasks, and at the post-task relaxation period. PPG pulses are decomposed into three waves (a main wave and two reflected waves) using a pulse decomposition analysis. Pulse waveform characteristics such as the time delay between the position of the main wave and reflected waves, the percentage of amplitude loss in the reflected waves, and the heart rate (HR) are calculated among others. The intra-subject difference of a feature value between two conditions is used as an index of autonomic reactivity. Results: Statistically significant individual differences from stress to recovery were found for HR and the percentage of amplitude loss in the second reflected wave ( A13 ) in both HC and MDD group. However, autonomic reactivity indices related to A13 reached higher values in HC than in MDD subjects (Cohen's d =0.81, AUC = 0.74), implying that the stress response in depressed patients is reduced. A statistically significant (p < 0.001) negative correlation (r = 0.5) between depression severity scores and A13 was found. Conclusion: A decreased autonomic reactivity is associated with higher degree of depression. Significance: Stress response quantification by dynamic changes in PPG waveform morphology can be an aid for the diagnosis and monitoring of depression.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Time Course of Low-Frequency Oscillatory Behavior in Human Ventricular Repolarization Following Enhanced Sympathetic Activity and Relation to Arrhythmogenesis

  • Sampedro-Puente, David Adolfo
  • Fernandez-Bes, Jesús
  • Szentandrassy, Norbert
  • Nanasi, Péter
  • Taggart, Peter
  • Pueyo, Esther
Background and Objectives: Recent studies in humans and dogs have shown that ventricular repolarization exhibits a low-frequency (LF) oscillatory pattern following enhanced sympathetic activity, which has been related to arrhythmic risk. The appearance of LF oscillations in ventricular repolarization is, however, not immediate, but it may take up to some minutes. This study seeks to characterize the time course of the action potential (AP) duration (APD) oscillatory behavior in response to sympathetic provocations, unveil its underlying mechanisms and establish a potential link to arrhythmogenesis under disease conditions. Materials and Methods: A representative set of human ventricular computational models coupling cellular electrophysiology, calcium dynamics, β-adrenergic signaling, and mechanics was built. Sympathetic provocation was modeled via phasic changes in β-adrenergic stimulation (β-AS) and mechanical stretch at Mayer wave frequencies within the 0.03–0.15 Hz band. Results: Our results show that there are large inter-individual differences in the time lapse for the development of LF oscillations in APD following sympathetic provocation, with some cells requiring just a few seconds and other cells needing more than 3 min. Whereas, the oscillatory response to phasic mechanical stretch is almost immediate, the response to β-AS is much more prolonged, in line with experimentally reported evidences, thus being this component the one driving the slow development of APD oscillations following enhanced sympathetic activity. If β-adrenoceptors are priorly stimulated, the time for APD oscillations to become apparent is remarkably reduced, with the oscillation time lapse being an exponential function of the pre-stimulation level. The major mechanism underlying the delay in APD oscillations appearance is related to the slow IKs phosphorylation kinetics, with its relevance being modulated by the IKs conductance of each individual cell. Cells presenting short oscillation time lapses are commonly associated with large APD oscillation magnitudes, which facilitate the occurrence of pro-arrhythmic events under disease conditions involving calcium overload and reduced repolarization reserve. Conclusions: The time course of LF oscillatory behavior of APD in response to increased sympathetic activity presents high inter-individual variability, which is associated with different expression and PKA phosphorylation kinetics of the IKs current. Short time lapses in the development of APD oscillations are associated with large oscillatory magnitudes and pro-arrhythmic risk under disease conditions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mechanisms Underlying Interactions Between Low-Frequency Oscillations and Beat-to-Beat Variability of Celullar Ventricular Repolarization in Response to Sympathetic Stimulation: Implications for Arrhythmogenesis

  • Sampedro-Puente, David Adolfo
  • Fernandez-Bes, Jesús
  • Porter, Bradley
  • Duijvenboden, Stef an van
  • Taggart, Peter
  • Pueyo, Esther
Background and Objectives: Enhanced beat-to-beat variability of ventricular repolarization (BVR) has been linked to arrhythmias and sudden cardiac death. Recent experimental studies on human left ventricular epicardial electrograms have shown that BVR closely interacts with low-frequency (LF) oscillations of activation recovery interval during sympathetic provocation. In this work human ventricular computational cell models are developed to reproduce the experimentally observed interactions between BVR and its LF oscillations, to assess underlying mechanisms and to establish a relationship with arrhythmic risk. Materials and Methods: A set of human ventricular action potential (AP) models covering a range of experimental electrophysiological characteristics was constructed. These models incorporated stochasticity in major ionic currents as well as descriptions of ß-adrenergic stimulation and mechanical effects to investigate the AP response to enhanced sympathetic activity. Statistical methods based on Automatic Relevance Determination and Canonical Correlation Analysis were developed to unravel individual and common factors contributing to BVR and LF patterning of APD in response to sympathetic provocation. Results: Simulated results reproduced experimental evidences on the interactions between BVR and LF oscillations of AP duration (APD), with replication of the high inter-individual variability observed in both phenomena. ICaL, IKr and IK1 currents were identified as common ionic modulators of the inter-individual differences in BVR and LF oscillatory behavior and were shown to be crucial in determining susceptibility to arrhythmogenic events. Conclusions: The calibrated family of human ventricular cell models proposed in this study allows reproducing experimentally reported interactions between BVR and LF oscillations of APD. Ionic factors involving ICaL, IKr and IK1 currents are found to underlie correlated increments in both phenomena in response to sympathetic provocation. A link to arrhythmogenesis is established for concomitantly elevated levels of BVR and its LF oscillations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Assessment of automatic strategies for combining QRS detections by multiple algorithms in multiple leads

  • Llamedo Mariano
  • Martínez Cortés, Juan Pablo
Objective: To develop and evaluate an algorithm for the selection of the best-performing QRS detections from multiple algorithms and ECG leads. Approach: The detections produced by several publicly available single-lead QRS detectors are segmented in 20 s consecutive windows; then a statistical model is trained to estimate a quality metric that is used to rank each 20 s segment of detections. The model describes each heartbeat in terms of six features calculated from the RR interval series, and one feature proportional to the number of heartbeats detected in other leads in a neighborhood of the current heartbeat. With the highest ranked segments, we defined several lead selection strategies (LSS) that were evaluated in a set of 1754 ECG recordings from 14 ECG databases. The LSS proposed were compared with simple strategies such as selecting lead II or the first lead available in a recording. The performance was calculated in terms of the average sensitivity, positive predictive value, and F score. Main results: The best-performing LSS, based on wavedet algorithm, achieved an F score of 98.7, with sensitivity S¿¿=¿¿99.2 and positive predictive value P¿¿=¿¿98.3. The F score for the simpler strategy using the same algorithm was 92.7. The LSS studied in this work have been made available in an open-source toolbox to ease the reproducibility and result comparison. Significance: The results suggest that the use of LSS is convenient for purposes of selecting the best heartbeat locations among those provided by different detectors in different leads, obtaining better results than any of the algorithms individually.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A Novel Paradigm for in Silico Simulation of Cardiac Electrophysiology Through the Mixed Collocation Meshless Petrov-Galerkin Method

  • Mountris, K.A.
  • Sanchez, C.
  • Pueyo, E.
Multi-scale cardiac electrophysiological modeling involves high computational load due to the inherent complexity as well as to limitations of the employed numerical methods (e.g., Finite Element Method - FEM). This study investigates the use of the Meshless Local Petrov-Galerkin Mixed Collocation (MLPG-MC) method to simulate cardiac electrophysiology. MLPG-MC is a truly meshless method where both the unknown function and its gradient are interpolated using nodal collocation. A 3 cm × 3 cm human ventricular tissue was simulated based on the monodomain reaction-diffusion model using the operator splitting technique. MLPG-MC or FEM were used to solve the diffusion term and the O''Hara-Virág-Varró-Rudy AP model to represent cellular electrophysiology at baseline and under 30% IKr inhibition (IKr30). Mean differences between MLPG-MC and FEM in AP duration at 90% (APD90), 50% (APD50) and 20% (APD20) repolarization levels were 4.47%, 4.16% and 3.29% for baseline conditions and 3.66%, 2.10% and 1.62% for IKr30 conditions. The computational time associated with each of the two methods was comparable. In conclusion, considering that MLPG-MC does not involve any mesh requirements and is well suited for massive parallelization, this study shows that it represents a promising alternative to FEM for cardiac electrophysiology simulations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Response of Ventricular Repolarization to Simulated Microgravity Measured by Periodic Repolarization Dynamics Using Phase-Rectified Signal Averaging

  • Palacios, S.
  • Caiani, E.G.
  • Pueyo, E.
  • Martínez, J.P.
Head-Down Bed Rest (HDBR) microgravity simulation induces cardiovascular deconditioning, including effects on ventricular repolarization. The index of Periodic Repolarization Dynamics (PRD) was developed to quantify low-frequency oscillations of cardiac repolarization. In this study, PRD was quantified by Phase Rectified Signal Averaging (PRDPRSA) and Continuous Wavelet Transform (PRDCWT) methods. PRD was analyzed in ECGs from 22 volunteers at rest and during orthostatic Tilt-Table Test (TTT) performed before and after -6° 60-days HDBR. Significant correlation was found between PRD measured by PRSA and CWT (Pearson''s ¿ = 0.93, p < 10-54 and Kendall''s t = 0.79 p < 10-38). A highly significant increase was found when PRDPRSA values were measured at POST-HDBR with respect to PRE-HDBR in the tilt phase: 1.40 [1.10] deg and 0.97 [0.90] deg (median [IQR]), p = 0.008, respectively. PRDPRSA also increased significantly in the tilt phase with respect to baseline, both at POST-HDBR (0.90 [0.57] deg, p = 0.003) and at PRE-HDBR (0.75 [0.45] deg, p = 0.011). PRD, either measured with PRSA or with CWT, is able to measure changes in ventricular repolarization induced by microgravity simulation as well as following sympathetic provocation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmogram Signal Morphology-Based Stress Assessment

  • Rinkevicius, M.
  • Kontaxis, S.
  • Gil, E.
  • Bailon, R.
  • Lázaro, J.
  • Laguna, P.
  • Marozas, V.
Stress is a healthy natural response to a perceived or actual threat. However, when stress is persistent, it may decrease work productivity, increase the risk of diseases, and affect the quality of life. Stress is reflected in physiological variables, such as heart rate, blood pressure, and pulse wave velocity among others. A photoplethys-mogram (PPG) contains information related to pulse rate and blood pressure. This study analyses parameters derived from PPG signal morphology for mental stress assessment.A low-complexity algorithm is designed using bandpass filtered higher-order derivatives of the PPG signal for estimation of six morphological parameters: the forward pulse wave amplitude A1, the systole and diastole durations T1 and Td, the time delays of reflected waves T12 and T13 from the renal and iliac sites in the central arteries, and the pulse duration Tp. The parameters were investigated on a set of 18 healthy subjects by using a modified Trier Social Stress Test.The results show that the most sensitive PPG morphology parameters to mental stress are the amplitude of forward wave A1, the duration of diastole Td, the time delay of the reflected wave T13, and the pulse-to-pulse interval Tp.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Influence of the Stimulation Current on the Differences between Cell and Tissue Electrophysiological Simulations

  • Monasterio, V.
  • Pueyo, E.
  • Rodríguez-Matas, J.F.
  • Carro, J.
This study compares stimulation waveforms for single-cell simulations. The alternatives include monophasic and biphasic current pulses, and a new waveform that resembles the transmembrane current responsible for conduction in tissue. Results indicate that the new stimulation produces the lowest mismatch between action potential markers simulated in cell and in tissue. In comparison with the monophasic stimulation, the new stimulation reduced cell-fiber differences by 99% for triangulation, by 95% for maximum transmembrane voltage, and by 76% for the maximum voltage slope. In conclusion, the new stimulation waveform could help to improve the trustworthiness of single-cell simulations in studies involving tissue-derived markers.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of the Heart Rate Variability Representations on the Quantification of the Cardiorespiratory Interactions during Autonomic Nervous System Blockade

  • Morales, J.F.
  • Bolea, J.
  • Van Huffel, S.
  • Bailón, R.
  • Varon, C.
The Heart Rate Variability (HRV) is a noninvasive tool to evaluate the activity of the autonomic nervous system. To study the HRV, different mathematical representations can be used. The selection of a representation might have an effect on the evaluation of the mechanisms that modulate the Heart Rate (HR). One of these mechanisms is the Respiratory Sinus Arrhythmia (RSA), i.e. an increased HR during inhalation and a decreased HR during exhalation. Different methods exist to quantify the RSA. A common approach is to calculate the power in the High Frequency (HF, 0.15 - 0.4 Hz) band of the spectrum of the HRV representation. More recently proposed methods use the respiratory signals to estimate the strength of the RSA.This paper studies the effect of the HRV representations on the quantification of the RSA. To this end, an experiment is used in which the sympathetic and parasympathetic branches of the autonomic nervous system are selectively blocked. Three different HRV representations are considered. Afterwards, the strength of the RSA is estimated using three approaches, namely the spectral content in the HF band of the HRV representations, orthogonal subspace projections and a time-frequency representation.The results suggest that the selection of an HRV representation does not have a significant impact on the RSA estimates in a healthy population.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Heart Rate Variability Monitoring Using a Wearable Armband

  • Lázaro, J.
  • Reljin, N.
  • Noh, Y.
  • Laguna, P.
  • Chon, K.H.
A wearable electrocardiogram (ECG) monitor is evaluated as heart rate variability (HRV) monitor. The device consists of an armband designed to be worn on the left upper arm which provides 3 ECG channels based on 3 pairs of dry (no hydrogel) electrodes. Armband-ECG and conventional-Holter-ECG signals were simultaneously recorded from 14 subjects during 5 minutes in supine position. Spacial principal component analysis was used to obtain a unique armband ECG signal in which the electromyogram contribution is attenuated. QRS complexes were automatically detected. Five traditional HRV parameters were derived: SDNN, RMSSD, pNN50, and powers within low frequency (LF, [0.04, 0.15] Hz) and high frequency (HF, [0.15, 0.4] Hz) bands. The Pearson''s correlation coefficient between the measurements from the armband device and the measures from the Holter device was computed. Results show very high correlations (1.0000, 0.9999, 0.9984, 1.0000, and 0.9999 for SDNN, RMSSD, pNN50, and powers at LF and HF, respectively), suggesting that the quality of armband-ECG signals is enough to estimate HRV parameters during stationary movement restricted conditions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Heart Rate Variability Analysis Assessment for Asthma Control Stratification

  • Milagro, J.
  • Soto, L.
  • Giner, J.
  • Varon, C.
  • Laguna, P.
  • Plaza, V.
  • Gil, E.
  • Bailón, R.
Autonomic nervous system (ANS) has been suggested to play a major role in the pathogenesis of asthma. This hypothesis has motivated large research, revealing a reduced modulation of the heart rate in subjects with uncontrolled asthma, when compared to asthmatics with controlled symptomatology. In this work, we assessed ANS activity through heart rate variability analysis in a group of asthmatics classified attending to the control of their symptoms. This information was later used for training a logistic regression classifier aiming at differentiating between the levels of control in asthmatic patients. The accuracy of the classifier improved when including ANS information (71.77%, versus 64.73% when only clinical parameters were considered), suggesting that ANS assessment could contribute to better non-invasive asthma monitoring.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

T-Wave Morphology Changes as Surrogate for Blood Potassium Concentration in Hemodialysis Patients

  • Palmieri, F.
  • Ramírez, J.
  • Laguna, P.
  • Gomis, P.
  • Ferreira, D.
  • Ruiz, J.E.
  • Bergasa, B.
  • Martín-Yebra, A.
  • Bukhari, H.A.
  • Pueyo, E.
  • Martínez, J.P.
End-stage renal disease (ESRD) patients undergoing hemodialysis (HD) are at high risk of arrhythmias and sudden cardiac death as a result of blood potassium concentration ([K+ ]) changes. The aim of this study is to investigate if dw, a time-warping-based electrocardiogram (ECG) biomarker of T-wave morphology changes, reflects [K+] evolution in HD patients, facilitating noninvasive [K+] monitoring and avoiding in-hospital blood tests analysis. 48-hour ECGs and a set of hourly-collected blood samples from 12 ESRD patients were acquired and analyzed. dw was calculated between a reference T-wave, measured at the end of the HD session, and the T-waves corresponding to each hour along the whole HD session, when [K+] was measured from blood samples. The values of dw correlated with the relative variations in [K+] with respect to the reference value (end of HD, ¿[K+ ]), with a median (interquartile) correlation coefficient of 0.90 (0.30), evidencing a strong relation between them. Our findings support the use of dw as a surrogate of ¿[K+], suggesting a potential use of dw for non-invasive hyperkalemia monitoring both in hospital and ambulatory settings.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Transmural Ventricular Heterogeneities Play a Major Role in Determining T-Wave Morphology at Different Extracellular Potassium Levels

  • Bukhari, H.A.
  • Palmieri, F.
  • Ferreira, D.
  • Potse, M.
  • Ramírez, J.
  • Laguna, P.
  • Sánchez, C.
  • Pueyo, E.
End-stage renal disease (ESRD) affects more than 10% of the world population. ESRD patients present impaired potassium homeostasis, which increases the risk for ventricular arrhythmias and sudden cardiac death. Noninvasive estimation of serum potassium, [K+], before the patient experiences serious consequences is of major importance. In this study, we investigated the relationship of [K+] with three T-wave morphological descriptors: the T-wave width (Tw), slope-to-amplitude ratio (TSA) and temporal morphological variability (dw) from ECGs of 12 ESRD patients undergoing hemodialysis and from simulated ECGs. Spearman''s correlation coefficients between the descriptors Tw, TSA and dw and [K+] were -0.5, 0. 8 and 0.65, respectively. These associations were, however, highly patient-dependent. The high inter-individual variability in T-wave morphology, particularly observed at high [K+], was reproduced in the simulations and could be explained by differences in transmural heterogeneities, with 10% variations in the proportion of midmyocardial cells leading to changes larger than 15% in T-wave morphology. In conclusion, T-wave morphological descriptors have the potential to be used as predictors of [K+] in ESRD patients, but their associated inter-individual variability should be taken into account, especially under hyperkalemic conditions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Cardiovascular Changes Induced by Acute Emotional Stress Estimated from the Pulse Transit Time Difference

  • Armañac, P.
  • Kontaxis, P.
  • Lázaro, J.
  • Laguna, P.
  • Bailón, R.
  • Gil, E.
In the present work, the difference between arrival times of photoplethysmographic (PPG) pulses from two different sites of the arterial tree (PTTD) is calculated. As the PTTD is considered to be related with arterial pulse wave velocity, an evaluation of it''s usefulness to identify states of acute mental stress is performed. A subset of fourteen healthy volunteers undergoing a stress protocol was analysed and a statistical test was carried out to evaluate the validity of the proposed method. The results showed that the standard deviation of the PTTD had sufficient statistical capacity to discern between states of stress and relaxation. Furthermore, a generalised descending trend of the mean PTTD can be seen from relaxation to stress.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Autonomic Nervous System Response to Heat Stress Exposure by Means of Heart Rate Variability

  • Kontaxis, S.
  • Bailon, R.
  • Rapalis, A.
  • Brazaitis, M.
  • Cernych, M.
  • Lazaro, J.
  • Laguna, P.
  • Gil, E.
  • Marozas, V.
In this study, a heart rate variability (HRV) analysis guided by respiration is conducted to assess changes in autonomic nervous system (ANS) regulation during pronounced heat stress induced by repetitive exposures to dry sauna in 13 young healthy subjects. The spectral power at the low frequency (LF) band [0.04, 0.15] Hz and at the high frequency band centered around the mean respiratory rate, estimated from ECG-derived respiration signals, are studied. The mean heart rate (HR), the total power of HRV, and the normalized LF power are also analyzed.Results show that mean HR and normalized LF power increase significantly after basal stage, not only during the sauna sessions, but also at the intermediate short rest stages and recovery phase after 30 min. A significant reduction in the total power of HRV during all sauna sessions is observed, while an increased power in LF band is shown only during recovery which might be related to improved cardiac function (increased cardiac output and reduced peripheral vascular resistance) after heat exposure. Respiratory rate does not change significantly during the protocol but a negative trend at stress stages may indicate a reverse reaction against an over-activation of the sympathetic branch. In conclusion, exposure to heat stress shifts sympathovagal balance of ANS toward sympathetic dominance that increases HR and diminishes HRV.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiorespiratory Coupling in Asthmatic Children

  • Milagro, J.
  • Gracia, J.
  • Seppä, V.P.
  • Karjalainen, J.
  • Paassilta, M.
  • Orini, M.
  • Gil, E.
  • Bailón, R.
  • Viik, J.
The relationship between cardiac and respiratory autonomic control has been suggested to be altered in several respiratory disorders. However, and despite the increasing prevalence of asthma, there are not studies assessing the cardiorespiratory coupling (CRC) with respect to the asthmatic status. Since altered autonomic control has been suggested to play a major role in asthma, in this work overnight CRC was assessed in a group of 67 children who underwent a three-month inhaled corticosteroids treatment. After treatment completion, CRC was reduced (p < 0.005) in the subjects without or with a low risk of asthma, whereas it kept unchanged in those with a worse prognosis, suggesting that an altered interaction between cardiac and respiratory activity might be related with an increased risk of asthma.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Multivariable relationships between autonomic nervous system related indices in hyperbaric environments

  • Perez-Martinez, C.
  • Pelaez-Coca, M.D.
  • Hernando, A.
  • Gil, E.
  • Sanchez, C.
The main aim of this work is to model the relationships between parameters extracted from the heart rate variability (HRV) signal, which is derived from the electrocardiogram (ECG), at different stages of a simulated immersion in a hyperbaric chamber. The response of the Autonomic Nervous System is known to be affected by changes in atmospheric pressure, reflected in changes in the HRV signal. A dataset consisting of ECG signals from 17 subjects exposed to a controlled hyperbaric environment, simulating depths from 0 m to 40 m, was used. Both linear and nonlinear dependences of HRV parameters were analysed using linear regression and Mutual Information (entropy-based) techniques. Furthermore, relationships between parameters of the HRV signals, biophysical variables of the subjects, and atmospheric pressure changes were characterized by artificial neural networks. In particular, self-organizing maps (SOM) were trained for modelling and clustering all the data. In the mid-term, these models could be the basis to create predictive models of HRV parameters at high depths in order to increase the safety for divers by warning them if some abnormal body response could be expected just by processing the ECG signal at sea level before immersion.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Photoplethysmographic Waveform in Hyperbaric Environment

  • Pelaez Coca, M.D.
  • Hernando, A.
  • Sanchez, C.
  • Lozano Albalate, M.T.
  • Izquierdo, D.
  • Gil, E.
The objective of this work is the identification of significant variations of morphological parameters of the photoplethysmographic (PPG) signal when the subjects are exposed to an increase in atmospheric pressure. To achieve this goal, the PPG signal of 26 subjects, exposed to a hyperbaric environment whose pressure increases up to 5 atm, has been recorded. From this record, segments of 4 minutes have been processed at 1 atm, 3 atm and 5 atm, both in the descending (D) and ascending (A) periods of the immersion. In total, four states (3D, 5, 3A and 1A) normalized to the basal state (1D) have been considered. In these segments, six morphological parameters of the PPG signal were studied. The width, the amplitude, the widths of the anacrotic and catacrotic phases, and the upward and downward slopes of each PPG pulse were extracted. The results showed significant increases in the three parameters related to the pulse width. This increase is significant in the four states analysed for the anacrotic phase width. Furthermore, a significant decrease in the amplitude and in both slopes (in the states 1A) was observed. These results show that the PPG width responds rapidly to the increase in pressure, indicating an activation of the sympathetic system, while amplitude and pulse slopes are decreased when the subjects are exposed to the hyperbaric environment for a considerable period of time.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of yoga on pulse rate variability measured from a venous pressure waveform

  • Hernando, D.
  • Nardelli, M.
  • Hocking, K.
  • Lazaro, J.
  • Alvis, B.
  • Gil, E.
  • Scilingo, E.P.
  • Brophy, D.R.
  • Valenza, G.
  • Laguna, P.
  • Brophy, C.
  • Bailon, R.
The benefits of yoga have been studied in different fields, from chronic health conditions to mental disorders, showing that it can help to improve the overall health. In particular, it has been proven that yoga also improves the autonomic function. Heart rate variability (HRV) at rest is commonly used as a non-invasive measure of autonomic regulation of heart rate. Alternatively, pulse rate variability (PRV) has been proposed as a surrogate of HRV. VoluMetrix has developed a novel technology that captures venous waveforms via sensors on the volar aspect of the wrist, called NIVAband. This study aims to assess the effect of yoga in the autonomic nervous system by analyzing the PRV obtained from the NIVA signal. Temporal (statistics of the normal-to-normal intervals), spectral (power in low and high frequency bands) and nonlinear (lagged Poincaré Plot analysis) parameters are analyzed before and after a yoga session in 20 healthy volunteers. The PRV analysis shows an increase in parameters related to parasympathetic activity and overall variability, and a decrease in parameters related to sympathetic activity and mean heart rate. These results support the beneficial effect of yoga in autonomic nervous system, increasing the parasympathetic activity.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Dynamical analysis of early afterdepolarization patterns in a biophysically detailed cardiac model

  • Barrio Gil, Roberto
  • Martinez Carballo, María Ángeles
  • Pueyo Paules, Esther
  • Serrano Pastor, Sergio
Arrhythmogenic early afterdepolarizations (EADs) are investigated in a biophysically detailed mathematical model of a rabbit ventricular myocyte, providing their location in the parameter phase space and describing their dynamical mechanisms. Simulations using the Sato model, defined by 27 state variables and 177 parameters, are conducted to generate electrical action potentials (APs) for different values of the pacing cycle length and other parameters related to sodium and calcium concentrations. A detailed study of the different AP patterns with or without EADs is carried out, showing the presence of a high variety of temporal AP configurations with chaotic and quasiperiodic behaviors. Regions of bistability are identified and, importantly, linked to transitions between different behaviors. Using sweeping techniques, one-, two-, and three-parameter phase spaces are provided, allowing ascertainment of the role of the selected parameters as well as location of the transition regions. A Devil’s staircase, with symbolic sequence analysis, is proposed to describe transitions in the ratio between the number of voltage (EAD and AP) peaks and the number of APs. To conclude, the obtained results are linked to recent studies for low-dimensional models and a conjecture is made for the internal dynamical structure of the transition region from non-EAD to EAD behavior using fold and cusp bifurcations and maximal canards. In a healthy heart, the sinoatrial node sends out an electrical impulse that spreads throughout the heart activating all cardiac myocytes to produce an electrical response called the action potential (AP). The AP follows a sequence of AP phases corresponding to the inflow and outflow of ions through the membrane of cardiac myocytes. Under some circumstances, that sequence of AP phases can be disrupted by the presence of the so-called early afterdepolarizations (EADs), which are secondary voltage depolarizations that can appear during phase 2 or 3 of the AP. Side effects of drugs, ion channel dysfunction, or oxidative stress, among others, can lead to the genesis of EADs.1–3 In heart failure, long QT syndrome, and other pathological conditions, EADs have been reported to be a relevant cause of fatal ventricular arrhythmias,4–6 but more knowledge is required to understand the theoretical mechanisms underlying their generation. During the last few decades, computational models of cardiac electrical activity have been instrumental in shedding light on various cardiac phenomena, including EADs. Biophysically detailed models of high dimension, i.e., with a large number of state variables, allow more faithful reproduction of experimental observations and facilitate biophysical interpretation. Here, we use the high-dimensional electrophysiological model of a rabbit ventricular myocyte developed by Sato et al.6 with 27 state variables and 177 model parameters. By combining different techniques for dynamical system analysis, we investigate the parameter phase space using three parameters reported to highly influence model dynamics.7 We identify regions in the phase space showing transitions from absence to presence of EADs through different temporal sequences of EADs. In these processes, dynamical phenomena are present, including bistability, chaos, fold, and cusp bifurcations. Putting all this information together and taking into account recent findings using low-dimensional models, we provide a conjecture about the internal dynamical structure of the transition region from absence to presence of EADs in the parameter phase space studied for the Sato model.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

SK Channel Block and Adrenergic Stimulation Counteract Acetylcholine-Induced Arrhythmogenic Effects in Human Atria

  • Celotto, Chiara
  • Sánchez, Carlos
  • Mountris, Konstantinos A.
  • Laguna, Pablo
  • Pueyo, Esther
There is increasing evidence on the role of the autonomic nervous system in the pathogenesis of atrial fibrillation. Interventions targeting autonomic modulation of atrial electrical activity have been shown to reduce the incidence of atrial arrhythmias. Additionally, recent investigations have proved that pharmacological therapies inhibiting small-conductance calcium-activated potassium (SK) channels are able to lessen cholinergic effects in the atria.In this study we use computational modeling and simulation to test individual and combined effects of SK channel block and adrenergic stimulation in counteracting detrimental effects induced by the parasympathetic neurotransmitter acetylcholine (ACh) on human atrial electrophysiology. Cell and tissue models are built that incorporate descriptions of SK channels as well as of isoproterenol (Iso)- and ACh-mediated regulation of the atrial action potential (AP). Three different cellular AP models, representing a range of physiological AP shapes, are considered and both homogeneous and heterogeneous ACh distributions in atrial tissue are simulated.At the cellular level, SK channel block is demonstrated to partially revert shortening of AP duration (APD) mediated by ACh at various doses, whereas 1 µM Iso has a variable response depending on the AP shape. The combination of SK block and Iso is in all cases able to take APD back to baseline levels, recovering between 82% and 120% of the APD shortening induced by 0.1 µM ACh. At the tissue level, SK block and Iso alone or in combination do not exert remarkable effects on conduction velocity, but the combination of the two is able to notably prolong the ACh-mediated APD shortening, thus increasing the wavelength for reentry.In conclusion, the results from this study support the combination of SK channel block and adrenergic stimulation as a potential option to counteract parasympathetically-mediated proarrhythmic effects in the human atria.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Location of parasympathetic innervation regions from electrograms to guide atrial fibrillation ablation therapy: an in silico modeling study

  • Celotto, Chiara
  • Sánchez, Carlos
  • Mountris, Konstantinos A.
  • Laguna, Pablo
  • Pueyo, Esther
The autonomic nervous system (ANS) plays an essential role in the generation and maintenance of cardiac arrhythmias. The cardiac ANS can be divided into its extrinsic and intrinsic components, with the latter being organized in an epicardial neural network of interconnecting axons and clusters of autonomic ganglia called ganglionated plexi (GPs). GP ablation has been associated with a decreased risk of atrial fibrillation (AF) recurrence, but the accurate location of GPs is required for ablation to be effective. Although GP stimulation triggers both sympathetic and parasympathetic ANS branches, a predominance of parasympathetic activity has been shown. This study aims was to develop a method to locate atrial parasympathetic innervation sites based on measurements from a grid of electrograms (EGMs). Electrophysiological models representative of non-AF, paroxysmal AF (PxAF), and persistent AF (PsAF) tissues were developed. Parasympathetic effects were modeled by increasing the concentration of the neurotransmitter acetylcholine (ACh) in randomly distributed circles across the tissue. Different circle sizes of ACh and fibrosis geometries were considered, accounting for both uniform diffuse and non-uniform diffuse fibrosis. Computational simulations were performed, from which unipolar EGMs were computed in a 16 × 1 6 electrode mesh. Different distances of the electrodes to the tissue (0.5, 1, and 2 mm) and noise levels with signal-to-noise ratio (SNR) values of 0, 5, 10, 15, and 20 dB were tested. The amplitude of the atrial EGM repolarization wave was found to be representative of the presence or absence of ACh release sites, with larger positive amplitudes indicating that the electrode was placed over an ACh region. Statistical analysis was performed to identify the optimal thresholds for the identification of ACh sites. In all non-AF, PxAF, and PsAF tissues, the repolarization amplitude rendered successful identification. The algorithm performed better in the absence of fibrosis or when fibrosis was uniformly diffuse, with a mean accuracy of 0.94 in contrast with a mean accuracy of 0.89 for non-uniform diffuse fibrotic cases. The algorithm was robust against noise and worked for the tested ranges of electrode-to-tissue distance. In conclusion, the results from this study support the feasibility to locate atrial parasympathetic innervation sites from the amplitude of repolarization wave.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Nonlinear T-Wave Time Warping-Based Sensing Model for Non-Invasive Personalised Blood Potassium Monitoring in Hemodialysis Patients: A Pilot Study

  • Palmieri, Flavio
  • Gomis, Pedro
  • Ruiz, José Esteban
  • Ferreira, Dina
  • Martín-Yebra, Alba
  • Pueyo, Esther
  • Martínez, Juan Pablo
  • Ramírez, Julia
  • Laguna, Pablo
Background: End-stage renal disease patients undergoing hemodialysis (ESRD-HD) therapy are highly susceptible to malignant ventricular arrhythmias caused by undetected potassium concentration ([K+]) variations (Δ[K+]) out of normal ranges. Therefore, a reliable method for continuous, noninvasive monitoring of [K+] is crucial. The morphology of the T-wave in the electrocardiogram (ECG) reflects Δ[K+] and two time-warping-based T-wave morphological parameters, dw and its heart-rate corrected version dw,c, have been shown to reliably track Δ[K+] from the ECG. The aim of this study is to derive polynomial models relating dw and dw,c with Δ[K+], and to test their ability to reliably sense and quantify Δ[K+] values. Methods: 48-hour Holter ECGs and [K+] values from six blood samples were collected from 29 ESRD-HD patients. For every patient, dw and dw,c were computed, and linear, quadratic, and cubic fitting models were derived from them. Then, Spearman’s (ρ) and Pearson’s (r) correlation coefficients, and the estimation error (ed) between Δ[K+] and the corresponding model-estimated values (Δ^[K+]) were calculated. Results and Discussions: Nonlinear models were the most suitable for Δ[K+] estimation, rendering higher Pearson’s correlation (median 0.77 ≤r≤ 0.92) and smaller estimation error (median 0.20 ≤ed≤ 0.43) than the linear model (median 0.76 ≤r≤ 0.86 and 0.30 ≤ed≤ 0.40), even if similar Spearman’s ρ were found across models (median 0.77 ≤ρ≤ 0.83). Conclusion: Results support the use of nonlinear T-wave-based models as Δ[K+] sensors in ESRD-HD patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Machine learning enables noninvasive prediction of atrial fibrillation driver location and acute pulmonary vein ablation success using the 12-lead ECG

  • Luongo, Giorgio
  • Azzolin, Luca
  • Schuler, Steffen
  • Rivolta, Massimo W.
  • Almeida, Tiago P.
  • Martínez, Juan P.
  • Soriano, Diogo C.
  • Luik, Armin
  • Müller-Edenborn, Björn
  • Jadidi, Amir
  • Dössel, Olaf
  • Sassi, Roberto
  • Laguna, Pablo
  • Loewe, Axel
Background: Atrial fibrillation (AF) is the most common supraventricular arrhythmia, characterized by disorganized atrial electrical activity, maintained by localized arrhythmogenic atrial drivers. Pulmonary vein isolation (PVI) allows to exclude PV-related drivers. However, PVI is less effective in patients with additional extra-PV arrhythmogenic drivers. Objectives: To discriminate whether AF drivers are located near the PVs vs extra-PV regions using the noninvasive 12-lead electrocardiogram (ECG) in a computational and clinical framework, and to computationally predict the acute success of PVI in these cohorts of data. Methods: AF drivers were induced in 2 computerized atrial models and combined with 8 torso models, resulting in 1128 12-lead ECGs (80 ECGs with AF drivers located in the PVs and 1048 in extra-PV areas). A total of 103 features were extracted from the signals. Binary decision tree classifier was trained on the simulated data and evaluated using hold-out cross-validation. The PVs were subsequently isolated in the models to assess PVI success. Finally, the classifier was tested on a clinical dataset (46 patients: 23 PV-dependent AF and 23 with additional extra-PV sources). Results: The classifier yielded 82.6% specificity and 73.9% sensitivity for detecting PV drivers on the clinical data. Consistency analysis on the 46 patients resulted in 93.5% results match. Applying PVI on the simulated AF cases terminated AF in 100% of the cases in the PV class. Conclusion: Machine learning–based classification of 12-lead-ECG allows discrimination between patients with PV drivers vs those with extra-PV drivers of AF. The novel algorithm may aid to identify patients with high acute success rates to PVI.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A real-time ppg peak detection method for accurate determination of heart rate during sinus rhythm and cardiac arrhythmia

  • Han, Dong
  • Bashar, Syed Khairul
  • Lázaro, Jesús
  • Mohagheghian, Fahimeh
  • Peitzsch, Andrew
  • Nishita, Nishat
  • Ding, Eric
  • Dickson, Emily L.
  • DiMezza, Danielle
  • Scott, Jessica
  • Whitcomb, Cody
  • Fitzgibbons, Timothy P.
  • McManus, David D.
  • Chon, Ki H.
Objective: We have developed a peak detection algorithm for accurate determination of heart rate, using photoplethysmographic (PPG) signals from a smartwatch, even in the presence of various cardiac rhythms, including normal sinus rhythm (NSR), premature atrial contraction (PAC), premature ventricle contraction (PVC), and atrial fibrillation (AF). Given the clinical need for accurate heart rate estimation in patients with AF, we developed a novel approach that reduces heart rate estimation errors when compared to peak detection algorithms designed for NSR. Methods: Our peak detection method is composed of a sequential series of algorithms that are combined to discriminate the various arrhythmias described above. Moreover, a novel Poincaré plot scheme is used to discriminate between basal heart rate AF and rapid ventricular response (RVR) AF, and to differentiate PAC/PVC from NSR and AF. Training of the algorithm was performed only with Samsung Simband smartwatch data, whereas independent testing data which had more samples than did the training data were obtained from Samsung’s Gear S3 and Galaxy Watch 3. Results: The new PPG peak detection algorithm provides significantly lower average heart rate and interbeat interval beat-to-beat estimation errors—30% and 66% lower—and mean heart rate and mean interbeat interval estimation errors—60% and 77% lower—when compared to the best of the seven other traditional peak detection algorithms that are known to be accurate for NSR. Our new PPG peak detection algorithm was the overall best performers for other arrhythmias. Conclusion: The proposed method for PPG peak detection automatically detects and discriminates between various arrhythmias among different waveforms of PPG data, delivers significantly lower heart rate estimation errors for participants with AF, and reduces the number of false negative peaks. Significance: By enabling accurate determination of heart rate despite the presence of AF with rapid ventricular response or PAC/PVCs, we enable clinicians to make more accurate recommendations for heart rate control from PPG data.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Spectral Analysis of Heart Rate Variability in Time-Varying Conditions and in the Presence of Confounding Factors

  • Sornmo, Leif
  • Bailon, Raquel
  • Laguna, Pablo
The tools for spectrally analyzing heart rate variability (HRV) has in recent years grown considerably, with emphasis on the handling of time-varying conditions and confounding factors. Time–frequency analysis holds since long an important position in HRV analysis, however, this technique cannot alone handle a mean heart rate or a respiratory frequency which vary over time. Overlapping frequency bands represents another critical condition which needs to be dealt with to produce accurate spectral measurements. The present survey offers a comprehensive account of techniques designed to handle such conditions and factors by providing a brief description of the main principles of the different methods. Several methods derive from a mathematical/statistical model, suggesting that the model can be used to simulate data used for performance evaluation. The inclusion of a respiratory signal, whether measured or derived, is another feature of many recent methods, e.g., used to guide the decomposition of the HRV signal so that signals related as well as unrelated to respiration can be analyzed. It is concluded that the development of new approaches to handling time-varying scenarios are warranted, as is benchmarking of performance evaluated in technical as well as in physiological/clinical terms.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Deep-Learning-Based Estimation of the Spatial QRS-T Angle from Reduced-Lead ECGs

  • Santos Rodrigues, Ana
  • Augustauskas, Rytis
  • Lukosevicius, Mantas
  • Laguna, Pablo
  • Marozas, Vaidotas
The spatial QRS-T angle is a promising health indicator for risk stratification of sudden cardiac death (SCD). Thus far, the angle is estimated solely from 12-lead electrocardiogram (ECG) systems uncomfortable for ambulatory monitoring. Methods to estimate QRS-T angles from reduced-lead ECGs registered with consumer healthcare devices would, therefore, facilitate ambulatory monitoring. (1) Objective: Develop a method to estimate spatial QRS-T angles from reduced-lead ECGs. (2) Approach: We designed a deep learning model to locate the QRS and T wave vectors necessary for computing the QRS-T angle. We implemented an original loss function to guide the model in the 3D space to search for each vector''s coordinates. A gradual reduction of ECG leads from the largest publicly available dataset of clinical 12-lead ECG recordings (PTB-XL) is used for training and validation. (3) Results: The spatial QRS-T angle can be estimated from leads {I, II, aVF, V2} with sufficient accuracy (absolute mean and median errors of 11.4 degrees and 7.3 degrees) for detecting abnormal angles without sacrificing patient comfortability. (4) Significance: Our model could enable ambulatory monitoring of spatial QRS-T angles using patch- or textile-based ECG devices. Populations at risk of SCD, like chronic cardiac and kidney disease patients, might benefit from this technology.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG modeling for simulation of arrhythmias in time-varying conditions

  • Bachi, Lorenzo
  • Halvaei, Hesam
  • Pérez, Cristina
  • Martín-Yebra, Alba
  • Petrenas, Andrius
  • Sološenko, Andrius
  • Johnson, Linda
  • Marozas, Vaidotas
  • Martínez, Juan Pablo
  • Pueyo, Esther
  • Stridh, Martin
  • Laguna, Pablo
  • Sörnmo, Leif
The present paper proposes an ECG simulator that advances modeling of arrhythmias and noise by introducing time-varying signal characteristics. The simulator is built around a discrete-time Markov chain model for simulating atrial and ventricular arrhythmias of particular relevance when analyzing atrial fibrillation (AF). Each state is associated with statistical information on episode duration and heartbeat characteristics. Statistical, time-varying modeling of muscle noise, motion artifacts, and the influence of respiration is introduced to increase the complexity of simulated ECGs, making the simulator well suited for data augmentation in machine learning. Modeling of how the PQ and QT intervals depend on heart rate is also introduced. The realism of simulated ECGs is assessed by three experienced doctors, showing that simulated ECGs are difficult to distinguish from real ECGs. Simulator usefulness is illustrated in terms of AF detection performance when either simulated or real ECGs are used to train a neural network for signal quality control. The results show that both types of training lead to similar performance.