Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Development of Mo/Au transition edge sensors for cryogenic x-ray detectors

  • Fàbrega, Lourdes
  • Camón, Agustín
  • Pobes, Carlos
  • Štrichovanec, Pavel
  • Moral-Vico, Javier
  • Casañ Pastor, Nieves
  • Jáudenes, Rosa M.
  • Sesé Monclús, Javier
Póster presentado al Encuentro RIA-SpaceTec: Nuevas perspectivas en el desarrollo de instrumentación astronómica en España, organizadas por la red SpaceTec-CM (Desarrollo de nuevas tecnologías para instrumentación espacial en la Comunidad de Madrid: S2013/ICE-2822 con el apoyo y la financiación de la Red de Infraestructuras en Astronomía (RIA-MINECO). Las jornadas se celebraron del 10 al 12 de febrero de 2016, en la Sede Central del CSIC (Serrano 117, Madrid)., The so-called Transition Edge Sensors (TES) , whose basic element is a superconducting film operating at cryogenic temperatures (~100mK), constitute high performance detectors for a very wide radiation range. Thus, they are considered essential for extremely sensitive astronomic instruments, either on ground or in space, such as EDELWEISS, CRESST, BICEP2, SCUBA2, ACTPol, SAFARI and ATHENA’s X-IFU, as well as for other applications in science and industry. TES X-ray detectors with extremely high spectral resolution have been fabricated by NASA and SRON, using respectively Mo/Au or Ti/Au bilayers as the sensing element and Bi or Au as absorber. We report here our progress in the fabrication of TES X-ray detectors based on Mo/Au bilayers, within the framework of the initiative to develop a european backup for the X-IFU detector. Mo/Au TES are fabricated on SiN membranes in Ultra High Vacuum conditions through a two-step deposition process, using sputtering and electron-beam deposition, followed by dry etching photolithography. Superconducting Nb wiring is used. Electrodeposited Bi is being developed as absorber. An advanced specific characterization setup has been implemented, involving complex impedance and I-V curve measurements using superconducting electronics in a dilution refrigerator (base temperature <30mK). The first results of characterization are presented., Work financed by the Spanish Ministerio de Economía y Competitividad (projects ESP2013-48637-C2-1-P, ESP2014-53672-C3-2-P and ESP2014-59309-JIN) and the European Commission (project AHEAD: Integrated Activities for the High Energy Astrophysics Domain ); RJ wishes to thank MINECO for her contract BES-2015-072733. We acknowledge also ESA contract No. 4000114932/15/NL/BW “Optimization of a European Transition Edge Sensor Array”., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Comparison of Ti/Au and Mo/Au TESs characterized under DC bias

  • Pobes, Carlos
  • Fàbrega, Lourdes
  • Camón, Agustín
  • Štrichovanec, Pavel
  • Moral-Vico, Javier
  • Casañ Pastor, Nieves
  • Jáudenes, Rosa M.
  • Sesé Monclús, Javier
  • Khosropanah, Pourya
  • Taralli, Emanuele
  • Nagayoshi, Kenichiro
Resumen del trabajo presentado al 13th Workshop on Low Temperature Electronics (WOLTE-13), celebrado en Sorrento (Italia) del 10 al 13 de septiembre de 2018., Transition Edge Sensors (TESs) are used as extremely sensitive thermometers in a wide range of applications. When coupled to a suitable absorber, they can detect, with unprecedented energy resolution, electromagnetic radiation from microwaves to gamma rays. To achieve this performance, they need to operate at very low temperatures, in the range of 100mK. In order to achieve superconductors with tunable critical temperature (Tc), bilayers made out of few nanometers of a superconductor and a normal metal are used. Depending on the selected materials and thicknesses, the Tc and normal resistance Rn of the device can be selected, which will impact their performance. Different groups worldwide develop TES for soft X-rays detection, mainly for future space missions. In Europe, SRON is developing Ti/Au sensors which are characterized under AC bias, adequate for the frequency domain multiplexing of several pixels. ICMA/ICMAB is developing sensors made of Mo/Au bilayers which are characterized under DC bias. Comparison of performances of the two types of sensors and the two operating conditions is basic for future development and optimization of this technology. In this communication we report on the comparison of Ti/Au and Mo/Au devices characterized under DC bias at ICMA facilities. We analyse the evolution of TES parameters at different operation points taking into account the differences between both materials and fabrication procedures., Work financed by the Spanish Ministerio de Economía y Competitividad (MINECO, projects ESP2014-59306-JIN, ESP2014-53672-C3-2-P, ESP2016-76683-C3-2-R), the European Space Agency (ESA, CTP Contract “Optimization of a European TES array”) and the European Commission (H2020 project AHEAD: Integrated Activities for the high energy astrophysics domain”). Personnel from ICMAB acknowledge financial support from MINECO, through the Severo Ochoa Programme for Centres of Excellence in R&D (SEV-2015-04969. RMJ wishes to thank MINECO for her FPI contract. We also thank PTB for providing the SQUIDs., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

The superconducting transition in TES: possible role of vortex pair unbinding

  • Fàbrega, Lourdes
  • Camón, Agustín
  • Pobes, Carlos
  • Štrichovanec, Pavel
  • Jáudenes, Rosa M.
Póster presentado al International Workshop on Low Temperature Detectors (LTD), celebrado en Milan (Italia) del 22 al 26 de julio de 2019., The R(T,I,H) shape of the superconducting transition of Transition Edge Sensors (TESs) is crucial for their operation and performances. Its sharpness as a function of temperature and current influences the devices noise. Also, the behaviour of the resistance as a function of these three parameters can provide understanding of the physical phenomena governing the transition, which in turn can be essential to define optimization routes. Estimates of fundamental lengths of TESs suggest that they behave as dirty type II superconductors, likely two-dimensional (2D). The onset of dissipation in 2D superconductors at H=0 is most often related to the so-called Berezinskii-Kosterlitz-Thouless transition, that is, the thermal unbinding of vortex-antivortex pairs: this may cause the motion of free vortices through the film, which would result in a voltage drop across it for any applied electrical current, and thus the appearance of a finite resistance at a temperature below the superconducting mean field critical temperature. This flux motion is considered a possible source of excess noise in TESs. We have performed a study of the resistive transition of Mo/Au-based TESs with diverse sizes and critical temperatures, under different applied electrical currents and magnetic fields. We have found a distinct analytic expression for R(T,I) at zero magnetic field, which holds for all the devices analysed at low biases, from the appearance of resistance up to quite high R/Rn values in some cases. We argue that this expression might be indicative of a current assisted vortex pair unbinding mechanism, and discuss the possible impact of such an effect on the TES parameters and performances., Work financed by the Spanish Ministerio de Ciencia, Innovación y Universidades-MICINN (projects ESP2016-76683-C3-2-R and RTI2018-096686-B-C22) and the European Commission (H2020 project AHEAD: “Integrated activities for the high energy astrophysics domain”). Personnel from ICMAB acknowledge financial support from MINECO, through the “Severo Ochoa” Programme for Centres of Excellence in R&D (SEV- 2015-0496). RMJ wishes to thank MINECO for her FPI contract.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

AC/DC characterization of a Ti/Au TES with Au/Bi absorber for X-ray detection, Characterization of a Ti/Au TES with Au/Bi absorber under AC and DC bias

  • Taralli, Emanuele
  • Pobes, Carlos
  • Khosropanah, Pourya
  • Fàbrega, Lourdes
  • Camón, Agustín
  • Gottardi, Luciano
  • Nagayoshi, Kenichiro
  • Ridder, M.
  • Bruijn, Marcel
  • Gao, J. R.
Resumen del póster presentado al International Workshop on Low Temperature Detectors (LTD), celebrado en Milan (Italia) del 22 al 26 de julio de 2019., Transition-edge sensors (TESs) are used as very sensitive thermometers and microcalorimeters aimed at different wavelengths detection. In particular, for soft X-ray astrophysics, science goals require very high resolution microcalorimeters which can be achieved with TESs coupled to suitable absorbers. For many applications there is also need for a high number of pixels, which means to be multiplexed in the readout stage. Frequency Domain Multiplexing (FDM) is the baseline readout scheme, proposed for the ATHENA mission. FDM requires biasing the TES in AC at MHz frequencies. Recently there has been reported degradation in performances under AC with respect to DC bias. In order to assess the performances of TESs to be used with FDM, it is thus of great interest to compare the performances of the same device under AC and DC bias. Of course this means using two completely different setups and two different way of thinking the characterization measurements. Here we report the preliminary results of a single pixel characterization performed on a TiAu TES under AC and afterwards under DC bias in different facilities. Extraction of dynamical parameters and noise performances are compared in both cases as a first step for further AC/DC comparison of these devices., This work is partly funded by European Space Agency (ESA) and coordinated with other European efforts under ESA CTP contract ITT AO/1-7947/14/NL/BW. CSIC work financed by the Spanish Ministerio de Ciencia, Innovación y Universidades-MICINN (projects ESP2016-76683-C3-2-R and RTI2018-096686-BC22) and the European Commission (H2020 project AHEAD: “Integrated activities for the high energy astrophysics domain”). Personnel from ICMAB acknowledge financial support from MINECO, through the “Severo Ochoa” Programme (SEV-2015-0496).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

TES X-ray pulse identification using CNNs

  • Vega-Ferrero, Jesús
  • Ceballos, María Teresa
  • Puyol-Gruart, J.
  • García, P.
  • Cobo, Beatriz
  • Carrera, Francisco J.
Póster presentado a la XXX Astronomical Data Analysis Software and Systems Conference, celebrada online del 8 al 12 de noviembre de 2020 en la University of Maryland, College Park Campus, USA., [Aims]: to detect and to reconstruct the pulses that X-ray photons produce at TES (Transition Edge Sensor) detectors (like the one in the Athena/X-IFU instrument), using Deep Learning techniques. The dataset used contains simulations performed with the Athena official simulator SIXTE., [Methods]: We construct and train a Convolution Neural Network (CNN) to differentiate between single, double and triple pulses. We use a hyper-parameter bayesian optimization to select the optimal CNN architecture., [Results]: we present the results of our CNN classification over 15,000 simulated pulses achieving excellent performance metrics., AHEAD (Integrated Activities for the High Energy Astrophysics Domain)., Peer reviewed