Resin-embedded murine ex vivo retina as durable models for optical coherence tomography

  • Barroso, Álvaro
  • Ketelhut, Steffi
  • Heiduschka, Peter
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
  • García-Torres, Fernando|||0000-0002-5337-8774
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] High-resolution optical coherence tomography (HR-OCT) systems require standardized, biologically relevant phantoms to enable reproducible performance evaluation and benchmarking. In this study, we present an optimized method for preparing durable 3D retina phantoms from resin-embedded ex vivo mouse eyes. Mechanical polishing and cutting techniques were applied to improve sample geometry, enabling better positioning of retinal tissue relative to the resin¿air interface. The modified samples were characterized by using a commercial HR-OCT system operating at 905¿nm. Quantitative analysis of B-scan images revealed enhanced signal contrast, particularly in the upper retinal layers, due to reduced scattering. This approach improves the anatomical fidelity and imaging performance of retina phantoms, offering a promising tool for calibration and comparative assessment of advanced HR-OCT systems., Funding by the European Union through the programs Horizon 2020 (Project GALAHAD, no.: 732613) and Horizon Europe (Project SEQUOIA; no.:101070062) are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

A Self-Training Framework for Glaucoma Grading In OCT B-Scans

  • García-Pardo, José Gabriel
  • Verdú-Monedero, Rafael
  • Dolz, Jose
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] In this paper, we present a self-training-based framework for glaucoma grading using OCT B-scans under the presence of domain shift. Particularly, the proposed two-step learning methodology resorts to pseudo-labels generated during the first step to augment the training dataset on the target domain, which is then used to train the final target model. This allows transferring knowledge-domain from the unlabeled data. Additionally, we propose a novel glaucoma-specific backbone which introduces residual and attention modules via skip-connections to refine the embedding features of the latent space. By doing this, our model is capable of improving state-of-the-art from a quantitative and interpretability perspective. The reported results demonstrate that the proposed learning strategy can boost the performance of the model on the target dataset without incurring in additional annotation steps, by using only labels from the source examples. Our model consistently outperforms the baseline by 1¿3% across different metrics and bridges the gap with respect to training the model on the labeled target data., We gratefully acknowledge the support of the Generalitat Valenciana (GVA) for the donation of the DGX A100 used for this work, action co-financed by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER) de la Comunitat Valenciana 2014-2020 (IDIFEDER/2020/030).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Resin-embedded ex vivo mouse retina as durable phantoms for optical coherence tomography

  • Barroso, Álvaro
  • Ketelhut, Steffi
  • Heiduschka, Peter
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
  • García-Torres, Fernando|||0000-0002-5337-8774
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Reliable performance testing, calibration, and comparative benchmarking of high-resolution optical coherence tomography (HR-OCT) systems requires durable and standardized phantoms with optical tissue properties. Here, we tested different sample preparation procedures combining various fixative mixtures, infiltration protocols and embedding resins for the establishment of durable retina phantoms. Sample quality was analyzed by evaluation of retina cell layers and tissue defects in volume scans acquired with a commercial HR-OCT system. Our results demonstrate that, by following appropriate preparation protocols, highly stable three-dimensional samples with layered structures as native healthy tissue can be fabricated. Even thin anatomic structures such as the ganglion single cell layer are preserved, which makes the new durable tissue phantoms highly suitable for reliable HR-OCT performance characterization., Funding by the European Union through the programs Horizon 2020 (Project GALAHAD, no.: 732613) and Horizon Europe (Project SEQUOIA; no.:101070062) are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Durable ex vivo mouse retina 3D tissue models for optical coherence tomography

  • Barroso, Álvaro
  • Heiduschka, Peter
  • Nettels-Hackert, Gerburg
  • Ketelhut, Steffi
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
  • García-Torres, Fernando|||0000-0002-5337-8774
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Durable phantoms with optical properties and layered structures like healthy and diseased tissues are highly desirable for reliable performance testing of novel high-resolution optical coherence tomography (HR-OCT) systems. In this context, we performed investigations on the establishment of durable 3D retina models from eyes dissected ex vivo from control mice and eyes from animals treated with N-methyl-D-aspartate (NMDA) which induces glaucoma-like tissue alterations. The comparison of data from resin-embedded tissue with native murine retina in gels demonstrates that by utilization of appropriate preparation protocols highly stable 3D samples with layered structures equivalent to native tissues can be fabricated which are suitable for reliable HR-OCT performance characterization., Funding by the European Union through the programs Horizon 2020 (Project GALAHAD, no.: 732613) and Horizon Europe (Project SEQUOIA; no.:101070062) are gratefully acknowledged.