Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Resin-embedded murine ex vivo retina as durable models for optical coherence tomography

  • Barroso, Álvaro
  • Ketelhut, Steffi
  • Heiduschka, Peter
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
  • García-Torres, Fernando|||0000-0002-5337-8774
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] High-resolution optical coherence tomography (HR-OCT) systems require standardized, biologically relevant phantoms to enable reproducible performance evaluation and benchmarking. In this study, we present an optimized method for preparing durable 3D retina phantoms from resin-embedded ex vivo mouse eyes. Mechanical polishing and cutting techniques were applied to improve sample geometry, enabling better positioning of retinal tissue relative to the resin¿air interface. The modified samples were characterized by using a commercial HR-OCT system operating at 905¿nm. Quantitative analysis of B-scan images revealed enhanced signal contrast, particularly in the upper retinal layers, due to reduced scattering. This approach improves the anatomical fidelity and imaging performance of retina phantoms, offering a promising tool for calibration and comparative assessment of advanced HR-OCT systems., Funding by the European Union through the programs Horizon 2020 (Project GALAHAD, no.: 732613) and Horizon Europe (Project SEQUOIA; no.:101070062) are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Using Diffusion Models for Data Augmentation on Limited Rodent OCT Datasets

  • García-Torres, Fernando|||0000-0002-5337-8774
  • del Amor, Rocío
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Barroso, Álvaro
  • Kemper, Björn
  • Schnekenburger, Jürgen
[EN] Optical coherence tomography (OCT) has transformed ophthalmology by enabling accurate diagnosis of retinal diseases. OCT in rodents is used in research studies of ophthalmic diseases and treatment evaluation. However, the scarcity of data limits the effectiveness of deep learning models for this purpose. This study explores the use of synthetic data generation to improve deep learning models for OCT image analysis from rodent retinas. To address this, the research leverages advanced class-conditional generative models to create high-quality synthetic images of ex-vivo rodent retinas embedded in two different mediums (solid resin and liquid media) with a reduced initial database. The conditional Denoising Diffusion Probabilistic Model (DDPM) proved to be the best model, as it produces more realistic images that closely mimic the characteristics of real rodent retinal scans. By augmenting the training datasets with these synthetic images, the performance of deep learning models in segmenting retinal layers improved by 7%. This approach reduces reliance on scarce biological samples and animal testing, promoting ethical research practices while improving the accuracy and efficiency of AI-driven medical diagnostics. The integration of synthetic data generation represents a significant advance in medical imaging, offering a scalable solution to data scarcity, generating reliable samples in two mediums and promoting the development of more robust and accurate diagnostic tools., This work has received funding from Horizon Europe, the European Union s Framework Programme for Research and Innovation, under Grant Agreement No. 101070062 (SEQUOIA). Generalitat Valenciana partially funded this work through project CIPROM/2022/20. The work of Sandra Morales has been cofunded by the Universitat Polit`ecnica de Val`encia, Spain through the program PAID10-20. The work of Rocio del Amor has been supported by the Spanish Ministry of Universities under an FPU Grant (FPU20/05263).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Durable 3D murine ex vivo retina glaucoma models for optical coherence tomography

  • Barroso, Álvaro
  • Ketelhut, Steffi
  • Nettels-Hackert, Gerburg
  • Heiduschka, Peter
  • Naranjo, Valery
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
[EN] Durable and standardized phantoms with optical properties similar to native healthy and disease-like biological tissues are essential tools for the development, performance testing, calibration and comparison of label-free high-resolution optical coherence tomography (HR-OCT) systems. Available phantoms are based on artificial materials and reflect thus only partially ocular properties. To address this limitation, we have performed investigations on the establishment of durable tissue phantoms from ex vivo mouse retina for enhanced reproduction of in vivo structure and complexity. In a proof-of-concept study, we explored the establishment of durable 3D models from dissected mouse eyes that reproduce the properties of normal retina structures and tissue with glaucoma-like layer thickness alterations. We explored different sectioning and preparation procedures for embedding normal and N-methyl-D-aspartate (NMDA)-treated mouse retina in transparent gel matrices and epoxy resins, to generate durable three-dimensional tissue models. Sample quality and reproducibility were quantified by thickness determination of the generated layered structures utilizing computer-assisted segmentation of OCT B-scans that were acquired with a commercial HR-OCT system at a central wavelength of 905 nm and analyzed with custom build software. Our results show that the generated 3D models feature thin biological layers close to current OCT resolution limits and glaucoma-like tissue alterations that are suitable for reliable HR-OCT performance characterization. The comparison of data from resin-embedded tissue with native murine retina in gels demonstrates that by utilization of appropriate preparation protocols, highly stable samples with layered structures equivalent to native tissues can be fabricated. The experimental data demonstrate our concept as a promising approach toward the fabrication of durable biological 3D models suitable for high-resolution OCT system performance characterization supporting the development of optimized instruments for ophthalmology applications., Horizon 2020 Project GALAHAD (732613); Horizon Europe Project SEQUOIA (101070062); Open Access Publication Fund of the University of Münster
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Resin-embedded ex vivo mouse retina as durable phantoms for optical coherence tomography

  • Barroso, Álvaro
  • Ketelhut, Steffi
  • Heiduschka, Peter
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
  • García-Torres, Fernando|||0000-0002-5337-8774
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Reliable performance testing, calibration, and comparative benchmarking of high-resolution optical coherence tomography (HR-OCT) systems requires durable and standardized phantoms with optical tissue properties. Here, we tested different sample preparation procedures combining various fixative mixtures, infiltration protocols and embedding resins for the establishment of durable retina phantoms. Sample quality was analyzed by evaluation of retina cell layers and tissue defects in volume scans acquired with a commercial HR-OCT system. Our results demonstrate that, by following appropriate preparation protocols, highly stable three-dimensional samples with layered structures as native healthy tissue can be fabricated. Even thin anatomic structures such as the ganglion single cell layer are preserved, which makes the new durable tissue phantoms highly suitable for reliable HR-OCT performance characterization., Funding by the European Union through the programs Horizon 2020 (Project GALAHAD, no.: 732613) and Horizon Europe (Project SEQUOIA; no.:101070062) are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Durable ex vivo mouse retina 3D tissue models for optical coherence tomography

  • Barroso, Álvaro
  • Heiduschka, Peter
  • Nettels-Hackert, Gerburg
  • Ketelhut, Steffi
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
  • García-Torres, Fernando|||0000-0002-5337-8774
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Durable phantoms with optical properties and layered structures like healthy and diseased tissues are highly desirable for reliable performance testing of novel high-resolution optical coherence tomography (HR-OCT) systems. In this context, we performed investigations on the establishment of durable 3D retina models from eyes dissected ex vivo from control mice and eyes from animals treated with N-methyl-D-aspartate (NMDA) which induces glaucoma-like tissue alterations. The comparison of data from resin-embedded tissue with native murine retina in gels demonstrates that by utilization of appropriate preparation protocols highly stable 3D samples with layered structures equivalent to native tissues can be fabricated which are suitable for reliable HR-OCT performance characterization., Funding by the European Union through the programs Horizon 2020 (Project GALAHAD, no.: 732613) and Horizon Europe (Project SEQUOIA; no.:101070062) are gratefully acknowledged.