Pasar al contenido principal

HIBRIDACION DE TECNOLOGIAS AVANZADAS DE ALMACENAMIENTO ELECTRICO PARA SISTEMAS BASADOS EN ENERGIAS RENOVABLES

DPI2016-80642-R

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2016
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD PUBLICA DE NAVARRA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Control strategy for an integrated photovoltaic-battery system

  • Urtasun Erburu, Andoni
  • Sanchis Gúrpide, Pablo
  • Marroyo Palomo, Luis
In photovoltaic-battery systems, more attention is usually paid to the MPPT control while the battery management is put aside. This paper proposes two control strategies for an integrated PV-battery system, both of them making it possible to perform MPPT or regulate the battery voltage to its maximum value in order to prevent it from overcharging. Simulation results prove the feasibility of both controls., This work was supported by the Spanish State Research Agency (AEI) and FEDER-UE under grants DPI2013-42853-R and DPI2016-80641-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Characterization and capacity dispersion of lithium-ion second-life batteries from electric vehicles

  • Braco Sola, Elisa
  • San Martín Biurrun, Idoia
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
Nowadays, electric vehicle batteries reutilization is considered such as a feasible alternative to recycling, as it allows to benefit from their remaining energy and to enlarge their lifetime. Stationary applications as self-consumption or isolated systems support are examples of possible second life uses for these batteries. However, the modules that compose these batteries have very heterogeneous properties, and therefore condition their performance. This paper aims to characterize and analyze the existing capacity dispersion of Nissan Leaf modules that have reached the end of their lifetime on their original application and of new modules of this Electric Vehicle, in order to establish a comparison between them., The authors would like to acknowledge the support of the Spanish State Research Agency (AEI) and FEDER-UE under grants DPI2016-80641-R and DPI2016-80642-R and of Government of Navarra through research projects PI020 RENEWABLE STORAGE and 0011-1411-2018-000029 GERA.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Influence of renewable power fluctuations on the lifetime prediction of lithium-ion batteries in a microgrid environment

  • Soto Cabria, Adrián
  • Berrueta Irigoyen, Alberto
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
This contribution analyses lifetime estimation errors due to the effect of power fluctuations in lithium-ion batteries connected to microgrids when different time steps are used for the calculations. Usually, not every second data are available or the computational cost is excessively high. Those facts result in the use of larger time steps. However, the increase of the time steps may turn out in too optimistic predictions. Data from a real microgrid make it possible to optimize calculation times while keeping low errors. The results show that when 1 minute time step is set, the computation time is reduced by 14.4 times while the lifetime overstatement is only 3.5-5.2% higher, depending on the aging model., The authors would like to acknowledge the support of the Spanish State Research Agency (AEI) and FEDER--UE under grants DPI2016-80641-R and DPI2016-80642-R and of Government of Navarra through research projects PI020 RENEWABLE-STORAGE and 0011-1411-2018-000029 GERA.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Worst expected ramp rates from cloud speed measurements

  • Wang, Guang Chao
  • Bosch, Juan Luis
  • Kurtz, Ben
  • Parra Laita, Íñigo de la
  • Wu, Elynn
Large PV power ramp rates are of concern and sometimes even explicitly restricted by grid operators. Battery energy storage systems can smooth the power output and maintain ramp rates within permissible limits. To enable PV plant and energy storage systems design and planning, a method to estimate the largest expected ramps for a given location is proposed. Because clouds are the dominant source of PV power output variability, an analytical relationship between the worst expected ramp rates, cloud motion vectors, and the geometrical layout of the PV plant is developed. The ability of the proposed method to bracket actual ramp rates is assessed over 8 months under different meteorological conditions, demonstrating an average compliance rate of 96.9% for a 2 min evaluation time window., Juan Luis Bosch has been financed in part by Projects ENE2017-83790-C3-3-R and ENE2014-59454-C3-2-R which were funded by the Ministerio de Ciencia, Innovación y Universidades and Ministerio de Economía y Competitividad, respectively, and co-financed by the European Regional Development Fund. In addition, Iñigo de la Parra has been partially supported by the Spanish State Research Agency (AEI) and FEDER-UE under grants DPI2016-80641-R and DPI2016-80642-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

On the requirements of the power converter for second-life lithium-ion batteries

  • Berrueta Irigoyen, Alberto
  • San Martín Biurrun, Idoia
  • Pascual Miqueleiz, Julio María
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
The use of lithium-ion batteries is increasing year after year, especially in the automotive sector. Given the high requirements of electric vehicles, their energy storage systems are discarded when they still have around 70% of its initial capacity. These discarded batteries are being studied as a low-price option for stationary systems, mostly related to renewable energy generation, with lower battery requirements. However, the increasing dispersion of cell capacity detailed in this contribution limits the use of second-life cells if regular battery management systems and power converters. We present in this contribution an experimental comparison of the capacity dispersion between fresh and second-life cells, and detail the relationship between the capacity dispersion and the required BMS functionality. Furthermore, we include the ageing phenomena in the analysis by means of experimental ageing results, given that the capacity dispersion is enlarged as the battery ages. After this, we use this data to quantify advantages and disadvantages of a combined BMS and power converter, based on a multilevel topology, compared to a conventional BMS. The most relevant result, when a 55-cell battery is analysed, is a 65% increase in capacity during its whole second life if the BMS and power converter are combined by means of a multilevel topology. The increased level of complexity required by the combined BMS-power converter architecture is analysed in this contribution, providing a convenient tool for the selection of the most suitable option for each application., The authors would like to acknowledge the support of the Spanish State Research Agency (AEI) and FEDER–UE under grants DPI2016-80641-R and DPI2016-80642-R and of Government of Navarra through research projects PI020 RENEWABLE-STORAGE and 0011-1411-2018-000029 GERA.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Critical comparison of energy management algorithms for lithium-ion batteries in renewable power plants

  • Berrueta Irigoyen, Alberto
  • Soto Cabria, Adrián
  • García Solano, Miguel
  • Parra Laita, Íñigo de la
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
Lithium-ion batteries are gaining importance for a variety of applications due to their price decrease and characteristics improvement. A good energy management strategy is required in order to increase the profitability of an energy system using a Li-ion battery for storage. The vast number of management algorithms that has been proposed to optimize the achieved profit, with diverse computational power requirements and using models with different complexity, raise doubts about the suitability of an algorithm and the required computation power for a particular application. The performance of three energy management algorithms based on linear, quadratic, and dynamic programming are compared in this work. A realistic scenario of a medium-sized PV plant with a constraint of peak shaving is used for this comparison. The results achieved by the three algorithms are compared and the grounds of the differences are analyzed. Among the three compared algorithms, the quadratic one seems to be the most suitable for renewableenergy applications, given the undue simplification of the battery aging required by the linear algorithm and the discretization and computational power required by a dynamic algorithm., The authors would like to acknowledge the support of the Spanish State Research Agency (AEI) and FEDER–UE under grants DPI2016-80641-R and DPI2016-80642-R and of Government of Navarra through research projects PI020 RENEWABLE-STORAGE and 0011-1411-2018-000029 GERA.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Ramp-rate control in large PV plants: battery vs. short-term forecast

  • Marcos Álvarez, Javier
  • Parra Laita, Íñigo de la
  • Cirés Buey, Eulalia
  • Wang, Guang Chao
  • García Solano, Miguel
  • Marroyo Palomo, Luis
Incluye póster, The changeability in the power produced by utility-scale PV plants caused by shadows due to passing clouds can compromise grid stability. Traditionally, some kind of energy storage systems (ESS) is proposed as the solution to reduce power variations below the limits imposed by new grid codes regulations. However, recent short-term forecast sources open the door to control the variability without batteries, using only inverter limitation. This option entails some energy curtailment losses that has not been yet addressed. This paper quantifies these losses for the first time using a meaningful database of 5 s one year data for a 38.5 MW PV plant in a perfect forecast scenery. Finally, we compare the economic cost of installing a lithium-ion battery vs. the inverter limitation solution. The results obtained indicate that battery-less strategies must not be neglected for ramp-rate control, since they can be more cost-effective using perfect forecast for any ramp value., This work has been supported by the Spanish State Research Agency (AEI) and FEDER-UE under grants DPI2016-80641-R and DPI2016-80642-R
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

On the on-site measurement of the degradation rate of crystalline silicon PV modules at plant level

  • Pascual Miqueleiz, Julio María
  • Berrueta Irigoyen, Alberto
  • Marcos Álvarez, Javier
  • García Solano, Miguel
  • Marroyo Palomo, Luis
This paper proposes a method for measuring the degradation rate of crystalline silicon PV modules at plant level in two different ways as a form of verification. As actual levels of degradation rate have been observed to be as low as 0.2%/a, the uncertainties make it difficult to measure this value accurately at plant level. However, despite the low value, it is still important to know the actual degradation rate due to its impact on energy yield. In this paper, two ways of measuring the degradation rate at plant level are proposed. These two methods, with different uncertainty sources, are proposed to be used jointly in order to have a better approach to the real value. Finally, an example of measurement in a 1.78 MW PV plant is presented., This work has been supported by the Spanish State Research Agency (AEI) and FEDER-UE under grants DPI2016-80641-R and DPI2016-80642-R
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Influence of the aging model of lithium-ion batteries on the management of PV self-consumption systems

  • Berrueta Irigoyen, Alberto
  • Pascual Miqueleiz, Julio María
  • San Martín Biurrun, Idoia
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
Lithium-ion batteries are gaining importance for a variety of applications due to their improving characteristics and decreasing price. An accurate knowledge of their aging is required for a successful use of these ESSs. The vast number of models that has been proposed to predict these phenomena raise doubts about the suitability of a model for a particular battery application. The performance of three models published for a Sanyo 18650 cylindrical cell in a self-consumption system are compared in this work. Measured photovoltaic production and home consumption with a sampling frequency of 15 minutes are used for this comparison. The different aging predictions calculated by these three models are analyzed, compared and discussed. These comparison is particularized for two management strategies. The first of them maximizes the self-consumption PV energy, while the second reduces the maximum power peak demanded from the grid., The authors would like to acknowledge the support of the Spanish State Research Agency (AEI) and FEDER-UE under grants DPI2013-42853-R, DPI2016-80641-R and DPI2016-80642-R; of Government of Navarra through research project PI038 INTEGRA-RENOVABLES; and the FPU Program of the Spanish Ministry of Education, Culture and Sport (FPU13/00542).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Analysis of the main battery characterization techniques and experimental comparison of commercial 18650 Li-ion cells

  • Soto Cabria, Adrián
  • Berrueta Irigoyen, Alberto
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
Over the coming years, major growth in the use of Li-ion batteries is expected, both in electric mobility as well as in stationary applications, be it in self-consumption systems and micro grids or in large renewable power generation plants. The proper characterization of lithium-ion cells is of vital importance for the development of precise models that permit the simulation and prediction of their behavior, so as to suitably configure cell groupings for the resulting battery packs, and to properly select the most suitable cells from the extensive manufacturer offer. In this work, an analysis is conducted of the main techniques used in the literature to characterize batteries. Also, an experimental comparative is carried out on 18650 Liion cells from three large global manufacturers, focusing on the primary methodologies used to characterize capacity, internal resistance and open circuit voltage. Finally, the advantages and disadvantages are presented for the methodologies used, based on the experimental results obtained., The authors would like to acknowledge the support of the Spanish State Research Agency (AEI) and FEDER-UE under grants DPI2016-80641-R and DPI2016-80642-R and of Government of Navarra through research projects PI020 RENEWABLE-STORAGE and 0011-1411-2018-000029 GERA.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Economic analysis of residential PV self-consumption systems with Li-ion batteries under different billing scenarios

  • Galilea Gil, Carlos
  • Pascual Miqueleiz, Julio María
  • Berrueta Irigoyen, Alberto
  • Ursúa Rubio, Alfredo
  • Marroyo Palomo, Luis
In this paper, an economic analysis for four houses with a PV self-consumption system with and without Li-ion batteries is carried out. In particular three different ways of sizing PV and batteries are analyzed under three different billing scenarios for the compensation of surplus energy injected into the grid. All methods run under the same energy strategy, which maximizes self-consumption. The three billing scenarios are: (1) no retribution for surplus energy, (2) retribution at pool price (net billing), and (3) monthly net metering. This study shows how fixed costs make these systems just profitable for small systems. Moreover, the results show how the battery cost and lifespan affects the final profitability of the system and what future evolution in these factors is needed for making these systems profitable under different billing methods., Almacenamiento Renovable Avanzado de Litio para Autoconsumo Residencial interconectado (ARALAR) ‒ 0011-1411-2017-000021, Proyecto de I+D Gobierno de Navarra, and Hibridación de tecnologías avanzadas de almacenamiento eléctrico para sistemas basados en energías renovables DPI2016-80642-R (HIBRITAER)
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Development of energy management strategies for the sizing of a fast charging station for electric buses

  • Ojer Palacios, Iñaki
  • Berrueta Irigoyen, Alberto
  • Pascual Miqueleiz, Julio María
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
The electric vehicle contributes to reduce greenhouse gases emissions and get a greater integration of renewable energy. In this context, the implementation of urban buses implies the development of new grid infrastructures in order to carry out the electricity supply required by the charging stations. In order to optimize the size of these infrastructures and to have more power capacity, this contribution proposes the design and the sizing of a fast charging station with a stationary energy storage system (ESS) installed, to supply the energy of the buses that run on one of the lines of Pamplona (Spain). In this contribution, first, the power demanded by the charging point is measured at the fast charging station located at the Public University of Navarre. Second, three energy management strategies are developed with which to use ESS. Finally, the proposed energy management strategies are simulated with the measured data obtained. The results achieved in this contribution show that with a 40 kWh ESS, the power demanded from the grid can be reduced by a whole 70%, that is, from 250 kW to 74 kW. In addition, the power contracted in the electricity rate is reduced too., The authors would like to acknowledge the support of the European Union under the H2020 project STARDUST (774094), the Spanish State Research Agency (AEI) and FEDER-UE under grants DPI2016-80641-R, DPI2016-80642-R, PID2019-111262RB-I00 and PID2019-110956RB-I00, the Government of Navarra through research project 0011-1411-2018-000029 GERA and the Public University of Navarre under project ReBMS PJUPNA1904.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

On the technical reliability of lithium-ion batteries in a zero emission polar expedition

  • Soto Cabria, Adrián
  • Berrueta Irigoyen, Alberto
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
  • Oficialdegui, Ignacio
This contribution presents a technical analysis of the Lithium-ion batteries (LIBs) used in the WindSled project. In this project, an expedition has been carried out by means of a 0-emission vehicle that have covered more than 2500 kilometers in Antarctica Eastern Plateau pulled by kites. This adventure allowed the performance of 10 scientific experiments with a minimal disturbance of the polar environment. The required electricity for the survival and the scientific experimentation was delivered by flexible PV panels installed on the sled and commercial LIBs. The study performed in this contribution aims at the quantification of the LIBs degradation after the expedition. The results show a capacity fade of 5 % and an internal resistance increase of 30 %. Based on these results, it can be claimed that the LIBs used in the WindSled Project can successfully operate under -40°C. Moreover, these batteries can be used in upcoming expeditions, entailing an improvement from an economical and environmental point of view compared to primary batteries., Spanish State Research Agency (AEI) and FEDER-UE under grants DPI2016-80641-R, DPI2016-80642-R, PID2019-111262RB-I00 and PID2019-110956RB-I00, the Government of Navarra through research project 0011-1411-2018- 000029 GERA and the Public University of Navarre under project ReBMS PJUPNA1904.