Publicación Contribución de congreso (ConferenceOutput)

Experimental characterization of the refrigerant distribution along a finned tubes heat exchanger

  • Sánchez-Moreno-Giner, Luis
  • López-Juárez, Emilio
  • López-Navarro, Alejandro|||0000-0002-0286-7965
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
[EN] According to the European Commission, heating, cooling and domestic hot water (DHW) production imply 79% of the total energy consumed in households. Moreover, as 84% of this energy is still generated from fossil fuels, it is required taking measures in order to improve the current situation. Following this intention, the path of the European Union is the reduction of the energy consumption and increasing the percentage of energy produced by renewable sources. One way to achieve the objectives set by the European Union is by the use of the heat pump powered by renewable sources, while the directive 2009/28/CE consider that heat pumps use renewable sources under certain conditions. Nowadays, refrigerants used by heat pumps are mainly hydrofluorocarbons (HFCs) which have a high global warming potential (GWP) and have a clear deadline defined at F-Gas EU Regulation 517/2014. For this reason, natural refrigerants, will play an important role within heating, cooling and DHW production at household sector. However, most of the natural refrigerants with acceptable thermodynamic properties are at least slightly flammable, and this attempt against the safety. For this reason, the amount of refrigerant charge must satisfy the maximum refrigerant charge limited by regulations, and the prediction of this maximum charge has become an important matter within the design process of a heat pump. Nevertheless, calculating the amount of refrigerant for a given heat pump is a difficult process with many uncertainties, like refrigerant mal-distribution in heat exchangers. In this work, an experimental characterization of the amount of refrigerant along the finned tubes heat exchanger (FTHE) of a heat pump working with R290 has been done. This qualitative and quantitative study has been carried out by measuring and comparing the temporary temperatures pattern distribution of the refrigerant in the FTHE, using thermocouples and thermographies, Luis Sánchez-Moreno-Giner acknowledges the Research and Development Aid Program (PAID01-17) of the Universitat Politècnica de València for receiving the Research Fellowship FPIUPV-2017.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Comparative study of the performance of a heat pump for heating with R410A and R32 as refrigerant, using the software IMST-ART

  • Sánchez-Moreno-Giner, Luis
  • López-Juárez, Emilio
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
[EN] According to the European Commission, at this moment, heating and cooling in buildings account for half of the energy consumption, while only a 16% of the energy used in this issue is obtained employing renewable sources. One of the possible solutions to improve the current situation is the use of heat pumps for the air conditioning of buildings. However, the refrigerants used at this moment are hydrofluorocarbons (HFCs) and they have a global warming potential (GWP) elevated so that new refrigerants which can substitute the current ones are being searched. The most used refrigerant for heating applications is the R410A, which is a mixture of HFCs. Its immediate retrofit is one of its components, the R32, due to the compatibility of both refrigerants with the materials and its similar performance. Furthermore, the R32 has a value of GWP approximately of a third of the R410 s value. The objective of this work is to evaluate the main differences between the results obtained with both refrigerants and to find out the main changes to be done to obtain at least the same performance. In this work, a model of IMST-ART of an air-water heat pump is presented using both refrigerants. In the model, both refrigerants are evaluated for different conditions of heating at low temperature. Lately, a summary of changes is proposed in order to cover the same functions, or more, than the original heat pump., Luis Sánchez-Moreno-Giner acknowledges the Research and Development Aid Program (PAID01-17) of the Universitat Politècnica de València for receiving the Research Fellowship FPIUPV-2017.