Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Experimental characterization of the refrigerant distribution along a finned tubes heat exchanger

  • Sánchez-Moreno-Giner, Luis
  • López-Juárez, Emilio
  • López-Navarro, Alejandro|||0000-0002-0286-7965
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
[EN] According to the European Commission, heating, cooling and domestic hot water (DHW) production imply 79% of the total energy consumed in households. Moreover, as 84% of this energy is still generated from fossil fuels, it is required taking measures in order to improve the current situation. Following this intention, the path of the European Union is the reduction of the energy consumption and increasing the percentage of energy produced by renewable sources. One way to achieve the objectives set by the European Union is by the use of the heat pump powered by renewable sources, while the directive 2009/28/CE consider that heat pumps use renewable sources under certain conditions. Nowadays, refrigerants used by heat pumps are mainly hydrofluorocarbons (HFCs) which have a high global warming potential (GWP) and have a clear deadline defined at F-Gas EU Regulation 517/2014. For this reason, natural refrigerants, will play an important role within heating, cooling and DHW production at household sector. However, most of the natural refrigerants with acceptable thermodynamic properties are at least slightly flammable, and this attempt against the safety. For this reason, the amount of refrigerant charge must satisfy the maximum refrigerant charge limited by regulations, and the prediction of this maximum charge has become an important matter within the design process of a heat pump. Nevertheless, calculating the amount of refrigerant for a given heat pump is a difficult process with many uncertainties, like refrigerant mal-distribution in heat exchangers. In this work, an experimental characterization of the amount of refrigerant along the finned tubes heat exchanger (FTHE) of a heat pump working with R290 has been done. This qualitative and quantitative study has been carried out by measuring and comparing the temporary temperatures pattern distribution of the refrigerant in the FTHE, using thermocouples and thermographies, Luis Sánchez-Moreno-Giner acknowledges the Research and Development Aid Program (PAID01-17) of the Universitat Politècnica de València for receiving the Research Fellowship FPIUPV-2017.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Comparative study of the performance of a heat pump for heating with R410A and R32 as refrigerant, using the software IMST-ART

  • Sánchez-Moreno-Giner, Luis
  • López-Juárez, Emilio
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
[EN] According to the European Commission, at this moment, heating and cooling in buildings account for half of the energy consumption, while only a 16% of the energy used in this issue is obtained employing renewable sources. One of the possible solutions to improve the current situation is the use of heat pumps for the air conditioning of buildings. However, the refrigerants used at this moment are hydrofluorocarbons (HFCs) and they have a global warming potential (GWP) elevated so that new refrigerants which can substitute the current ones are being searched. The most used refrigerant for heating applications is the R410A, which is a mixture of HFCs. Its immediate retrofit is one of its components, the R32, due to the compatibility of both refrigerants with the materials and its similar performance. Furthermore, the R32 has a value of GWP approximately of a third of the R410 s value. The objective of this work is to evaluate the main differences between the results obtained with both refrigerants and to find out the main changes to be done to obtain at least the same performance. In this work, a model of IMST-ART of an air-water heat pump is presented using both refrigerants. In the model, both refrigerants are evaluated for different conditions of heating at low temperature. Lately, a summary of changes is proposed in order to cover the same functions, or more, than the original heat pump., Luis Sánchez-Moreno-Giner acknowledges the Research and Development Aid Program (PAID01-17) of the Universitat Politècnica de València for receiving the Research Fellowship FPIUPV-2017.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Recent trends in oil structuring using hydrocolloids

  • Bascuas-Véntola, Santiago Martín
  • Morell-Esteve, Pere
  • Hernando Hernando, Mª Isabel|||0000-0002-3322-935X
  • Quiles Chuliá, Mª Desamparados|||0000-0003-4991-6629
[EN] Solid fats provide desirable functionality, texture, and palatability to foods; however, they are related to adverse chronic health effects. Consumers and regulatory authorities are demanding more natural and healthy ingredients. Thus, in context of the high demand for healthy foods and the transition to more sustainable ingredients, oil structuring emerges as an outstanding strategy to substitute saturated and trans fats. Researchers have developed optimised indirect routes to structure oil with hydrocolloids resulting in gelled emulsions and oleogels. Novel healthy food structures based on polysaccharides, proteins, and their supramolecular interactions are suitable to create several types of healthy colloidal systems with unique sensory, texture, and stability properties., The authors would like to thank Universitat Politecnica de Valencia by FPI-UPV 2017 grant and the project RTI-2018-099738-B-C22 from the 'Ministerio de Ciencia, Innovacion y Universidades'. They would also like to thank Phillip John Bentley for assistance in correcting the English manuscript.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A Distributed Approach for Collision Avoidance between Multirotor UAVs Following Planned Missions

  • FABRA COLLADO, FRANCISCO JOSE
  • Zamora-Mero, Willian Jesus
  • Sangüesa-Escorihuela, Julio Alberto
  • Tavares De Araujo Cesariny Calafate, Carlos Miguel|||0000-0001-5729-3041
  • Cano, Juan-Carlos|||0000-0002-0038-0539
  • Manzoni, Pietro|||0000-0003-3753-0403
[EN] As the number of potential applications for Unmanned Aerial Vehicles (UAVs) keeps rising steadily, the chances that these devices get close to each other during their flights also increases, causing concerns regarding potential collisions. This paper proposed the Mission Based Collision Avoidance Protocol (MBCAP), a novel UAV collision avoidance protocol applicable to all types of multicopters flying autonomously. It relies on wireless communications in order to detect nearby UAVs, and to negotiate the procedure to avoid any potential collision. Experimental and simulation results demonstrated the validity and effectiveness of the proposed solution, which typically introduces a small overhead in the range of 15 to 42 s for each risky situation successfully handled., This work was partially supported by the "Ministerio de Ciencia, Innovacion y Universidades, Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad, Proyectos I+D+I 2018", Spain, under Grant RTI2018-096384-B-I00, and the Universitat Politecnica de Valencia (UPV) under grant number FPI-2017-S1 for the training of PhD researchers.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

MUSCOP: Mission-Based UAV Swarm Coordination Protocol

  • Fabra Collado, Francisco José
  • Zamora, Willian
  • Reyes, Pablo
  • Sangüesa, Julio A.
  • Tavares De Araujo Cesariny Calafate, Carlos Miguel|||0000-0001-5729-3041
  • Cano, Juan-Carlos|||0000-0002-0038-0539
  • Manzoni, Pietro|||0000-0003-3753-0403
[EN] Nowadays, Unmanned Aerial Vehicles (UAVs) have become the preferred, and sometimes the only support tool when facing critical scenarios such as earthquakes, search and rescue missions, and border surveillance. In these scenarios, deploying a UAV swarm instead of a single UAV can provide additional benefits when, for example, cargo carrying requirements exceed the lifting power of a single UAV, or when the deployment of several UAVs simultaneously can accelerate the accomplishment of the mission, and broaden the covered area. To this aim, in this paper we present MUSCOP, a protocol that allows multiple UAVs to perfectly coordinate their flight when performing planned missions. Experimental results show that the proposed protocol is able to achieve a high degree of swarm cohesion independently of the swarm formation adopted, and even in the presence of very lossy channels, achieving minimal synchronization delays and very low position offsets with regard to the ideal case., This work was supported in part by the Ministerio de Ciencia, Innovacion y Universidades, Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad, Proyectos I+D+I 2018, Spain, under Grant RTI2018-096384-B-I00, and in part by the Universitat Politecnica de Valencia (UPV) for the training of Ph.D. researchers under Grant FPI-2017-S1.