Pasar al contenido principal

USO DE MATERIALES DE ALTAS PRESTACIONES PARA LA MEJORA DE LA RESISTENCIA FRENTE AL FUEGO DE COLUMNAS MIXTAS CON SECCIONES DE ACERO EMBEBIDAS EN HORMIGON

PID2019-105908RB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Post-fire residual strength and ductility of structural steels from hollow sections

  • Pons Aliaga, David|||0000-0002-9034-9550
  • Lapuebla-Ferri, Andrés|||0000-0001-9667-236X
  • Romero, Manuel L.|||0000-0001-5247-4767
[EN] Steel structures are severely affected by the extreme temperatures reached during a fire. After this, if the structure has not collapsed, the remaining elements can be reused if they are not excessively distorted or the material is still fit for service. In the last case, residual properties of steel must be adequate and fulfil the requirements of the current standards. On this matter, it is hypothesized that residual behaviour of steel not only depends on the highest temperature reached during the fire episode, but also on the load it was simultaneously bearing. This work is focused on an experimental study on the post-fire behaviour of structural steels. Specimens were cut from structural steel (S355) cold-formed circular hollow sections (CHS) and subjected to a combination of tensile stress and high temperature. Afterwards, the specimens were cooled in air back to room temperature and, finally, load was increased until specimen failure. The obtained results allowed discussing on the residual yield strength, ultimate strength and stiffness of the steel, and a special focus was put on the residual ductility. The results of this work can provide a basis to the appraisal of steel structures after fire, supporting the further decision on its reinstatement or subsequent demolition., The authors would like to express their sincere gratitude for the help provided through the Grant PID2019-105908RB-I00 funded by MCIN/AEI/ 10.13039/501100011033.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Numerical investigation on the thermal behaviour of steel-reinforced CFST columns in fire

  • Medall-Martos, David|||0000-0001-9212-5326
  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Albero, V|||0000-0001-7193-9232
  • Ibáñez, Carmen|||0000-0002-9354-5637
  • Romero, Manuel L.|||0000-0001-5247-4767
[EN] In previous research, the authors highlighted the limited fire resistance of slender concrete-filled steel tubular (CFST) columns. A possible solution for enhancing the fire resistance of such columns consists of embedding an open steel profile within the concrete infill of the CFST section, generating the so-called steel-reinforced concrete-filled steel tubular (SR-CFST) section, where the inner steel profile results thermally protected by the surrounding concrete, thus delaying its degradation at elevated temperatures. This strategy may result beneficial in the fire situation as compared to other sectional configurations where the steel parts are directly exposed to the heat source. In this paper, a two-dimensional finite element model will be developed for studying the thermal behaviour of SR-CFST columns and validated by comparing the temperature distribution results with experimental tests available in the literature. The numerical model will be subsequently used to carry out parametric studies, in order to analyse the influence of the different parameters, such as the cross-section shape, outer tube thickness or the inner steel profile sectional dimensions over the thermal response of these composite sections when subjected to fire. Finally, a simplified temperature distribution proposal will be developed, which may help practitioners for a fast evaluation of the cross-sectional temperature field of SR-CFST columns at a given fire resistance period by assigning an equivalent temperature to each component of the composite section (hollow steel tube, concrete encasement and inner steel profile). This simplified temperature proposal may result helpful when evaluating the sectional capacity of SR-CFST columns in fire, by using a single strength and stiffness value for each component of the composite cross-section corresponding to its temperature., The authors would like to express their sincere gratitude for the help provided through the Grant PID2019-105908RB-I00 and for the first author's pre-doctoral contract through the Grant PRE2020-093106 funded by MCIN/AEI/ 10.13039/501100011033 and by "ESF Investing in your future".
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Experimental evaluation of the load-bearing capacity of steel-reinforced CFST stub columns under a fire scenario

  • Medall-Martos, David|||0000-0001-9212-5326
  • Ibáñez, Carmen|||0000-0002-9354-5637
  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Romero, Manuel L.|||0000-0001-5247-4767
[EN] Composite construction is becoming increasingly used across the world, since it enables to exploit the benefits of steel and concrete working together, leading to costeffective solutions. Recent technological developments have facilitated the introduction of new typologies, which combined with the use of high performance materials allow for significant load-bearing capacities with reduced cross-sectional dimensions. One of these innovative composite sections are the so-called steel-reinforced concrete-filled steel tubular (SR-CFST) columns, where an open steel profile is embedded into a CFST section. Apart from the broadly recognized benefits of these typologies at room temperature, they show an enhanced fire performance due to the inherent fire protection offered by the surrounding concrete to the inner steel profile, which delays its loss of mechanical capacity at elevated temperatures. However, the experimental evidence on the fire behaviour of SR-CFST columns is still scarce, being much needed for the development of specific design provisions that consider the use of the inner steel profile in CFST columns. In this paper, a new testing program on the thermo-mechanical behaviour of SRCFST columns is presented to extend the available experimental database. A cylindrical electric furnace attached to a loading rig equipped with a 5000 kN hydraulic jack is used. In total six SR-CFST stub columns are tested, three circular and three square sections, combining high strength steel and concrete., The authors would like to express their sincere gratitude for the help provided through the Grant PID2019-105908RB-I00 and for the first author's pre-doctoral contract through the Grant PRE2020-093106 funded by MCIN/AEI/ 10.13039/501100011033 and by ¿ESF Investing in your future¿. The authors are deeply grateful to Dr Enrique Serra for his help and assessment to prepare and conduct the experiments and Dr Andrés Lapuebla-Ferri and Dr David Pons for their help in conducting the material tests.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Modelo numérico bidimensional para la evaluación del comportamiento térmico de columnas tubulares de acero rellenas de hormigón con perfiles embebidos en situación de incendio

  • Medall-Martos, David|||0000-0001-9212-5326
  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Albero, V|||0000-0001-7193-9232
  • Ibáñez, Carmen|||0000-0002-9354-5637
  • Romero, Manuel L.|||0000-0001-5247-4767
[ES] Cada vez es más común el uso de columnas mixtas de acero-hormigón en edificación, debido a las importantes reducciones de sección que permiten. En los últimos años, se han realizado numerosas investigaciones en la tipología CFST (¿Concrete Filled Steel Tubular column¿). Pese a ello, esta tipología se ve comprometida debido a su limitada resistencia al incendio en casos de elevada esbeltez. Con el fin de mejorar dicho comportamiento surge la tipología de columnas SR-CFST (¿Steel Reinforced Concrete Filled Steel Tubular column¿), que consiste en embeber dentro de la sección un perfil de acero estructural. En este artículo se presenta el desarrollo de un modelo de elementos finitos bidimensional que se ha utilizado para analizar el comportamiento térmico de las columnas SR-CFST en situación de incendio. Dicho modelo ha sido validado por comparación con los resultados experimentales que se encuentran disponibles en la bibliografía como los de Zhu et al. y los de Dotreppe et al., entre otros. Se hace uso del modelo numérico para llevar a cabo estudios paramétricos con el fin de discernir qué influencia tienen diferentes parámetros sobre la resistencia a compresión de la sección a temperatura elevada. Algunos de estos parámetros son la forma de la sección (cuadrada o circular), las dimensiones del perfil interior, el espesor de la pared del tubo de acero o la humedad del hormigón. Teniendo en cuenta los resultados que se obtienen del estudio paramétrico, queda como trabajo futuro el desarrollo de una propuesta de distribución de temperaturas simplificada para cada una de las partes que conforman la sección, de cara a facilitar el cálculo de este tipo de secciones mixtas a temperatura elevada., Los autores agradecen el apoyo proporcionado a través de la Ayuda PID2019-105908RB-I00 y por el contrato predoctoral del primer autor a través de la Ayuda PRE2020-093106 financiadas por MCIN/AEI/ 10.13039/501100011033 y por FSE Invierte en tu futuro.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Influence of load and high temperature on the post-fire behaviour of high-strength structural steels

  • Lapuebla-Ferri, Andrés|||0000-0001-9667-236X
  • Pons Aliaga, David|||0000-0002-9034-9550
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Gardner, Leroy
[EN] In this work, an experimental campaign was carried out to evaluate the post-fire mechanical performance of high-strength steel specimens (grade S700) when being subjected simultaneously to different combinations of tensile load and elevated temperature. To this end, transient-state tests were firstly carried out to obtain the `critical temperature¿, i.e., the temperature at which a specimen failed while being simultaneously subjected to tensile load and heated at a constant temperature rate. Secondly, post-fire tests were performed on unloaded as well as loaded specimens. For that purpose, specimens were heated to temperatures below the critical temperature, cooled down in air and finally submitted to tensile testing. In order to investigate the influence of production route, specimens were extracted from coldformed circular hollow sections and hot-rolled sheets. Moreover, coupons with five different thicknesses were tested to investigate the influence of section thickness on the post-fire behaviour. Residual values of yield strength, ultimate strength, elastic modulus and ductility were determined from the tests and discussed., The authors would like to express their sincere gratitude for the help provided through the Grant PID2019-105908RB-I00.