Pasar al contenido principal

CLINICALLY-GUIDED DATA PROCESSING METHODS AND IN SILICO MODELS TO IMPROVE PATIENT STRATIFICATION AND THERAPY RESPONSE IN CARDIAC AND NEUROLOGICAL DISORDERS

PID2022-140556OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Temporal variability of ventricular activation in brugada syndrome patients

  • Romagnoli, Sofía
  • Isabel Roquero, Alba
  • Martín-Yebra, Alba
  • Palmieri, Flavio|||0000-0002-1455-4923
  • Pueyo Paules, Esther
  • Gomis Román, Pedro|||0000-0002-2058-7115
  • Laguna Lasaosa, Pablo
  • Arbelo Lainez, Elena
  • Mincholé, Ana
In Brugada Syndrome (BrS), ventricular fibrillation events peak during night. This temporal pattern suggests that circadianity may modulate arrhythmogenesis. The present work evaluates the circadianity of ventricular activation in BrS patients from 24-hour ECGs with the high-precordial leads. Lead-dependent propagation progression times, \(T_l^p(h)\), are computed every \(h\)-th half hour in each \(l\)-th lead as the time instant along the QRS complex when the QRS energy reaches a percentage, \(p\), of the total QRS energy. \(T_l^p(h)\) is characterized by median and standard deviation over 24 hours, as well as the MESOR and amplitude of the cosinor analysis. The median and MESOR of \(T_l^{70}(h)\) are longer by more than 10 ms in BrS patients than in controls. In particular, the median and standard deviation of \(T_l^p(h)\) at different energy percentages can distinguish between BrS vs controls (\(\mathrm{AUC} \geq 0.8\)), and BrS-I vs BrS-II (\(\mathrm{AUC} = 0.78\)). Cosinor analysis indicates that \(T_l^p(h)\) is less influenced by circadianity than heart rate. The Spearman correlation of \(T_l^p(h)\) with heart rate is lower than 0.5 in each lead for both BrS and controls. These findings suggest that intra-day variability in propagation progression times is not primarily driven by circadianity or heart rate. Furthermore, the temporal variability of \(T_l^p(h)\) is higher in symptomatic BrS patients supporting its potential role as risk stratification marker in BrS., Funding was provided ISCIII Spain (ref: PI24/00691); EU Reference Network ERN GUARD-Heart; MICIN through projects CNS2022-135899, TED2021-130459B- I00, PID2023-148975OB-I00 and PID2022-140556OBI00, through fellowship RYC2019-027420-I; Aragon Government group: BSICoS T39 23R; EU MSCA COFOUND postdoct project ARISTOS, GA:101081334., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

T-wave peak-to-end morphology restitution as biomarker in Brugada syndrome

  • Gómez, Neurys
  • Ramírez, Julia
  • Isabel Roquero, Alba
  • Palmieri, Flavio|||0000-0002-1455-4923
  • Arbelo Lainez, Elena
  • Mártinez, Juan Pablo
  • Laguna Lasaosa, Pablo
Brugada syndrome (BrS) is a genetic disorder that affects the ion channels of the cardiac myocites, resulting in a higher predisposition to malignant ventricular arrhythmias and sudden cardiac death (SCD). Risk stratification and management of BrS patients remains a major clinical challenge. In this work, we use a time-warping-based index of the T-wave peak-to-end morphological restitution (TPEMR) to quantify the restitution properties of the late phase of ventricular repolarization and evaluate its ability to distinguish between control and BrS patients and between symptomatic (BrS-S) and asymptomatic patients (BrS-A). 24-hour Holter ECG recordings from 89 BrS patients (29 asymptomatic, BrS-A, and 60 symptomatic, BrS-S) and 32 healthy control patients were analyzed. The original, unweighted \(\mathrm{TPEMR}_{O}\) as well as weighted versions with two different strategies \(\mathrm{TPEMR}_{W1}\) and \(\mathrm{TPEMR}_{W2}\) are computed. \(\mathrm{TPEMR}\) derives from a time-warping, \(d\mathrm{PCA}^{w,T_{pe}}\), index computed from T waves at two distant RR bins normalized by the RR range. All the three TPEMR indices were significantly higher for BrS group than for the control group. BrS-S group presented higher TPEMR indexes than BrS-A group for all indices, though significant differences were only shown in the weighted \(\mathrm{TPEMR}_{W2}\) index., Funding was provided by MICIN, Spain, projects: PID2022-140556OB-I00, CNS2023-143599 and TED2021-130459B-I00, and fellowship RYC2021-031413-I, and by Aragon Government group: BSICoS T39 23R., Peer Reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Non-Linear Modeling and Analysis of Amplifier-Less Potentiostat Architectures

  • Sannino, Andrea
  • Wiens, David-Peter
  • Ortmanns, Maurits
  • Artigas, José I.
  • Otín, Aránzazu
In this article, a previously published amplifier-less potentiostat architecture is further examined. Starting with a linearized model, the impact of the most important parameters is studied taking in account the electrodes-solution electrochemical interface. A detailed model is obtained and thoroughly verified, and recommended operating conditions are given for certain limit load conditions. Then, a more complete non-linear model is developed to take in account the measurement uncertainty introduced by the circuit non-linear components. This non-linear model is compared to a time domain description of the circuit and it is verified that it can predict the non-linear behavior with a precision better than 20%. This result enables the circuit designers to compensate for these effects and ultimately reduce the overall measurement uncertainty.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

An Improved Discrete Time Amplifier-Less Potentiostat Architecture for Metabolic Sensing Applications

  • Sannino, Andrea
  • Artigas, José I.
  • Otín, Aránzazu
In this paper, an improved discrete-time potentiostat architecture is proposed. The focus is placed on the digital controller, aiming to enhance its performances, reduce measurement uncertainty and increase speed. The system is modeled including its non-linear behavior, and the impact of the digital controller parameters on the system response is analyzed through behavioral simulations. The developed mathematical model shows good agreement with the simulation results. The new controller successfully reduces the measurement uncertainty compared to a purely integral control system by up to a factor of 100 in the worst-case scenario. The system speed is also improved by approximately 40%. The new digital controller not only improves the overall performance of the system, but also does not increase significantly the hardware complexity of the system.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

T-wave peak-to-end morphology restitution as biomarker in Brugada syndrome

  • Gómez, Neurys
  • Ramírez, Julia
  • Isabel Roquero, Alba
  • Palmieri, Flavio
  • Arbelo Lainez, Elena
  • Mártinez, Juan Pablo
  • Laguna Lasaosa, Pablo
Brugada syndrome (BrS) is a genetic disorder that affects the ion channels of the cardiac myocites, resulting in a higher predisposition to malignant ventricular arrhythmias and sudden cardiac death (SCD). Risk stratification and management of BrS patients remains a major clinical challenge. In this work, we use a time-warping-based index of the T-wave peak-to-end morphological restitution (TPEMR) to quantify the restitution properties of the late phase of ventricular repolarization and evaluate its ability to distinguish between control and BrS patients and between symptomatic (BrS-S) and asymptomatic patients (BrS-A). 24-hour Holter ECG recordings from 89 BrS patients (29 asymptomatic, BrS-A, and 60 symptomatic, BrS-S) and 32 healthy control patients were analyzed. The original, unweighted \(\mathrm{TPEMR}_{O}\) as well as weighted versions with two different strategies \(\mathrm{TPEMR}_{W1}\) and \(\mathrm{TPEMR}_{W2}\) are computed. \(\mathrm{TPEMR}\) derives from a time-warping, \(d\mathrm{PCA}^{w,T_{pe}}\), index computed from T waves at two distant RR bins normalized by the RR range. All the three TPEMR indices were significantly higher for BrS group than for the control group. BrS-S group presented higher TPEMR indexes than BrS-A group for all indices, though significant differences were only shown in the weighted \(\mathrm{TPEMR}_{W2}\) index., Funding was provided by MICIN, Spain, projects: PID2022-140556OB-I00, CNS2023-143599 and TED2021-130459B-I00, and fellowship RYC2021-031413-I, and by Aragon Government group: BSICoS T39 23R., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Temporal variability of ventricular activation in brugada syndrome patients

  • Romagnoli, Sofía
  • Isabel Roquero, Alba
  • Martín-Yebra, Alba
  • Palmieri, Flavio
  • Pueyo Paules, Esther
  • Gomis Román, Pedro
  • Laguna Lasaosa, Pablo
  • Arbelo Lainez, Elena
  • Mincholé, Ana
In Brugada Syndrome (BrS), ventricular fibrillation events peak during night. This temporal pattern suggests that circadianity may modulate arrhythmogenesis. The present work evaluates the circadianity of ventricular activation in BrS patients from 24-hour ECGs with the high-precordial leads. Lead-dependent propagation progression times, \(T_l^p(h)\), are computed every \(h\)-th half hour in each \(l\)-th lead as the time instant along the QRS complex when the QRS energy reaches a percentage, \(p\), of the total QRS energy. \(T_l^p(h)\) is characterized by median and standard deviation over 24 hours, as well as the MESOR and amplitude of the cosinor analysis. The median and MESOR of \(T_l^{70}(h)\) are longer by more than 10 ms in BrS patients than in controls. In particular, the median and standard deviation of \(T_l^p(h)\) at different energy percentages can distinguish between BrS vs controls (\(\mathrm{AUC} \geq 0.8\)), and BrS-I vs BrS-II (\(\mathrm{AUC} = 0.78\)). Cosinor analysis indicates that \(T_l^p(h)\) is less influenced by circadianity than heart rate. The Spearman correlation of \(T_l^p(h)\) with heart rate is lower than 0.5 in each lead for both BrS and controls. These findings suggest that intra-day variability in propagation progression times is not primarily driven by circadianity or heart rate. Furthermore, the temporal variability of \(T_l^p(h)\) is higher in symptomatic BrS patients supporting its potential role as risk stratification marker in BrS., Funding was provided ISCIII Spain (ref: PI24/00691); EU Reference Network ERN GUARD-Heart; MICIN through projects CNS2022-135899, TED2021-130459B- I00, PID2023-148975OB-I00 and PID2022-140556OBI00, through fellowship RYC2019-027420-I; Aragon Government group: BSICoS T39 23R; EU MSCA COFOUND postdoct project ARISTOS, GA:101081334., Peer Reviewed, Postprint (published version)