Publicación Contribución de congreso (ConferenceOutput)

Modeling liver electrical conductivity during hypertonic injection

  • Castellví Fernández, Quim
  • Sánchez Velázquez, Patricia, 1985-
  • Moll, Xavier
  • Berjano, Enrique J.
  • Andaluz, Anna
  • Burdío Pinilla, Fernando
  • Bijnens, Bart
  • Ivorra Cano, Antoni, 1974-
Metastases in the liver frequently grow as scattered tumor nodules which neither can be removed by surgical resection nor focally ablated. Previously, we have proposed a novel technique based on irreversible electroporation which may be able to simultaneously treat all nodules in the liver while sparing healthy tissue. The proposed technique requires increasing the electrical conductivity of healthy liver by injecting a hypersaline solution through the portal vein. Aiming to assess the capability of increasing the global conductivity of the liver by means of hypersaline fluids, here it is presented a mathematical model which estimates the NaCl distribution within the liver and the resulting conductivity change. The model fuses wellestablished compartmental pharmacokinetic models of the organ with saline injection models employed for resuscitation treatments and it considers changes in sinusoidal blood viscosity due to the hypertonicity of the solution. Here it is also described a pilot experimental study in pigs in which different volumes of NaCl 20% (from 100 to 200 ml) were injected through the portal vein at different flow rates (from 53 to 171 ml/min). The in vivo conductivity results fit those obtained by the model, both quantitatively and qualitatively, being able to predict the maximum conductivity with a 14.6% average relative error. The maximum conductivity value was 0.44 S/m which corresponds to increasing four times the mean basal conductivity (0.11 S/m). The results suggest that the presented model is well suited for predicting on liver conductivity changes during hypertonic saline injection., Spanish Government; contract/grant number: TEC2014-52383-C3-1-R, TEC2014-52383-C3-2-R and TEC2014-52383-C3-3-R
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Charge counter for performing active charge-balance in miniaturized electrical stimulators

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Functional Electrical Stimulation (FES) has been explored in order to restore the capabilities of the nervous system in patients that suffer from paralysis. This area of research and of clinical practice greatly benefits from any technological improvement yielding miniaturization. In this regard, we recently proposed and demonstrated an innovative electrical stimulation method based on implanted microstimulators that operate as rectifiers of bursts of innocu-ous high frequency current supplied by skin electrodes, gener-ating low frequency currents that are capable of stimulating excitable tissues. We envision flexible ultrathin implants (di-ameters < 300 μm) containing ASICs that have advanced ca-pabilities, such as addressability and current control. As min-iaturization is the main aim of this method, the use of bulky DC-blocking capacitors (e.g. 10 μF) to accomplish zero net charge injection and avoid electrochemical tissue and electrode damage is highly inconvenient. As an alternative, here we present an active charge-balance method based on the use of a digital charge quantifier, whose operation is inspired in the functioning of the tipping bucket rain gauge. The system moni-tors the charge injection, matching the charge injected in the cathodal phase, with the charge injected in the anodal phase, generating a biphasic current waveform that adapts itself to possible current source mismatches. We have implemented a prototype built with discrete components which uses a capaci-tor of only 100 pF for the charge counter., AI’s research is supported by a Ramón y Cajal fellowship/nfrom the Spanish government and a Marie Curie grant/n(IRG 256376) from the European Commission. LBF’s research/nis supported by a scholarship from the UPF.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Modeling liver electrical conductivity during hypertonic injection

  • Castellví Fernández, Quim
  • Sánchez Velázquez, Patricia, 1985-
  • Moll, Xavier
  • Berjano, Enrique J.
  • Andaluz, Anna
  • Burdío Pinilla, Fernando
  • Bijnens, Bart
  • Ivorra Cano, Antoni, 1974-
Metastases in the liver frequently grow as scattered tumor nodules which neither can be removed by surgical resection nor focally ablated. Previously, we have proposed a novel technique based on irreversible electroporation which may be able to simultaneously treat all nodules in the liver while sparing healthy tissue. The proposed technique requires increasing the electrical conductivity of healthy liver by injecting a hypersaline solution through the portal vein. Aiming to assess the capability of increasing the global conductivity of the liver by means of hypersaline fluids, here it is presented a mathematical model which estimates the NaCl distribution within the liver and the resulting conductivity change. The model fuses wellestablished compartmental pharmacokinetic models of the organ with saline injection models employed for resuscitation treatments and it considers changes in sinusoidal blood viscosity due to the hypertonicity of the solution. Here it is also described a pilot experimental study in pigs in which different volumes of NaCl 20% (from 100 to 200 ml) were injected through the portal vein at different flow rates (from 53 to 171 ml/min). The in vivo conductivity results fit those obtained by the model, both quantitatively and qualitatively, being able to predict the maximum conductivity with a 14.6% average relative error. The maximum conductivity value was 0.44 S/m which corresponds to increasing four times the mean basal conductivity (0.11 S/m). The results suggest that the presented model is well suited for predicting on liver conductivity changes during hypertonic saline injection., Spanish Government; contract/grant number: TEC2014-52383-C3-1-R, TEC2014-52383-C3-2-R and TEC2014-52383-C3-3-R
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Charge counter for performing active charge-balance in miniaturized electrical stimulators

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Functional Electrical Stimulation (FES) has been explored in order to restore the capabilities of the nervous system in patients that suffer from paralysis. This area of research and of clinical practice greatly benefits from any technological improvement yielding miniaturization. In this regard, we recently proposed and demonstrated an innovative electrical stimulation method based on implanted microstimulators that operate as rectifiers of bursts of innocu-ous high frequency current supplied by skin electrodes, gener-ating low frequency currents that are capable of stimulating excitable tissues. We envision flexible ultrathin implants (di-ameters < 300 μm) containing ASICs that have advanced ca-pabilities, such as addressability and current control. As min-iaturization is the main aim of this method, the use of bulky DC-blocking capacitors (e.g. 10 μF) to accomplish zero net charge injection and avoid electrochemical tissue and electrode damage is highly inconvenient. As an alternative, here we present an active charge-balance method based on the use of a digital charge quantifier, whose operation is inspired in the functioning of the tipping bucket rain gauge. The system moni-tors the charge injection, matching the charge injected in the cathodal phase, with the charge injected in the anodal phase, generating a biphasic current waveform that adapts itself to possible current source mismatches. We have implemented a prototype built with discrete components which uses a capaci-tor of only 100 pF for the charge counter., AI’s research is supported by a Ramón y Cajal fellowship/nfrom the Spanish government and a Marie Curie grant/n(IRG 256376) from the European Commission. LBF’s research/nis supported by a scholarship from the UPF.