Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 34
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Bidirectional communications in wireless microstimulators based on electronic rectification of epidermically applied currents

  • Ivorra Cano, Antoni, 1974-
  • Becerra Fajardo, Laura
Comunicació presentada a 7th Annual International IEEE/EMBS Conference on Neural Engineering, celebrada a Montpellier, França, del 22 al 24 d'abril de 2015., Functional Electrical Stimulation (FES) has been used in order to restore muscle functions in patients suffering from neurological disorders. This therapeutic approach benefits from technological improvements that yield miniaturization. We previously have proposed and demonstrated an innovative electrical stimulation method in which wireless implants act as rectifiers of innocuous high frequency (HF) currents. These currents are conductively supplied to the tissues where the/nimplants are located through external electrodes. Locally, the implants generate low frequency currents capable of stimulating excitable tissues. The method has the potential to enable unprecedented levels of miniaturization. The implant needs only two peripheral electrodes both for picking-up the HF current and for performing electrical stimulation. In addition, a tiny hybrid microcircuit, or a single integrated circuit, may integrate all the necessary electronic components. No bulky parts such as coils or batteries are required. We have demonstrated a number of circuit architectures for the implants with advanced capabilities such as digital addressability. In/nhere, we demonstrate that the proposed method also allows bidirectional communications between the implants and the external system that powers and governs them, enabling proprioception-like sensing capabilities that may be crucial for closed-loop FES systems. We demonstrate a scheme based on amplitude modulation and Manchester encoding., AI‟s research is supported by a Ramón y Cajal fellowship from the Spanish government and a Marie Curie grant (IRG 256376) from the European Commission. LBF‟s research is supported by a scholarship from the UPF.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Remote electrical stimulation by means of implanted rectifiers

  • Ivorra Cano, Antoni, 1974-
Miniaturization of active implantable medical devices is currently compromised by the available means for electrically/npowering them. Most common energy supply techniques for implants – batteries and inductive couplers – comprise bulky/nparts which, in most cases, are significantly larger than the circuitry they feed. Here, for overcoming such miniaturization/nbottleneck in the case of implants for electrical stimulation, it is proposed to make those implants act as rectifiers of high/nfrequency bursts supplied by remote electrodes. In this way, low frequency currents will be generated locally around the/nimplant and these low frequency currents will perform stimulation of excitable tissues whereas the high frequency currents/nwill cause only innocuous heating. The present study numerically demonstrates that low frequency currents capable of/nstimulation can be produced by a miniature device behaving as a diode when high frequency currents, neither capable of/nthermal damage nor of stimulation, flow through the tissue where the device is implanted. Moreover, experimental/nevidence is provided by an in vivo proof of concept model consisting of an anesthetized earthworm in which a commercial/ndiode was implanted. With currently available microelectronic techniques, very thin stimulation capsules (diameter/n,500 mm) deliverable by injection are easily conceivable., This author's research is currently supported by a Ramón y Cajal fellowship from the Spanish Ministry for Science and Innovation (RYC-2009-04271) and a Marie Curie International Reintegration Grant (256376 – “TAMIVIVE”) from the European Commission. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Impact of liver vasculature on electric field distribution during electroporation treatments: an anatomically realistic numerical study

  • Qasrawi, Radwan Fayez Hasan
  • Ivorra Cano, Antoni, 1974-
Electroporation is the phenomenon in which cell membrane permeability is increased by exposing the cell to high intensity electric fields. In living tissues, such permeabilization boost can be used in order to enhance the penetration of drugs or DNA plasmids or to destroy undesirable cells and it is typically performed by applying pulsed high voltages across needle electrodes. When used for ablation, and particularly in the context of liver tumors, it is often claimed that in contrast with thermal ablation techniques, electroporation is not severely impacted by the presence of large blood vessels because the heat sinking characteristic of those is not relevant for the electric field distribution. However, blood vessels do distort the electric field distribution because of their high inner conductivity. The goal of the study presented here is to numerically analyze the relevance of such distortion in a clinical scenario. An anatomically realistic model of the liver and its vasculature within an abdominal section was implemented. The blood vessels ranged from 0.3 to 6.3 mm in diameter and from 24 to 68.56 mm in length. A series of simulations with plausible random locations and depths (needle tips from 10 to 25mm within the liver) for the electrode pairs was conducted. Locations and depths were carefully verified so that the electrodes did not penetrate the vessels. The results were compared to those assuming that liver tissue is homogeneous. These comparisons indicate that volume error caused by neglecting the presence of vessels is less than 3%, which can be considered negligible if compared to other error sources. However, it was noticed that if the treated region comprises vessels or is very close to them, undertreated and over treated spots will appear around the vessels. Since undertreated spots may imply that tumor cells remain viable after treatment, caution is advised., This work has received financial support from the Spanish Government through grant TEC2010-17285 ―MEPVIVO‖ and from the European Commission through the Marie Curie IRG grant ―TAMIVIVE‖ (256376).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Tumor growth delay by adjuvant alternating electric fields which appears non-thermally mediated

  • Castellví Fernández, Quim
  • Ginestà, Mireia M.
  • Capellá, Gabriel
  • Ivorra Cano, Antoni, 1974-
Delivery of the so-called Tumor Treatment Fields (TTFields) has been proposed as a cancer/ntherapy. These are low magnitude alternating electric fields at frequencies from 100 to 300 kHz/nwhich are applied continuously in a non-invasive manner. Electric field delivery may produce an/nincrease in temperature which cannot be neglected. We hypothesized that the reported results/nobtained by applying TTFields in vivo could be due to heat rather than to electrical forces as/npreviously suggested. Here it is presented an in vivo study in which pancreatic tumors/nsubcutaneously implanted in nude mice were treated for a week either with mild hyperthermia/n(41°C) or with TTFields (6 V/cm, 150 kHz) and tumor growth was assessed. Although the TTFields/napplied singly did not produce any significant effect, the combination with chemotherapy did show/na delay in tumor growth in comparison to animals treated only with chemotherapy (median relative/nreduction = 47%). We conclude that concomitant chemotherapy and TTFields delivery show a/nbeneficial impact on pancreatic tumor growth. Contrary to our hypothesis, this impact is nonrelated/nwith the induced temperature increase., This research was supported by project grants (AR00311 - MICINN-TEC2010-11182-E, SAF2012-/n33636, RTICCC RD12/0036/0031) from the Spanish government and in part by a Marie Curie grant/n(IRG 256376) from the European Commission and by the Generalitat de Catalunya (2009 SGR/n1356).
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

3D Assessment of irreversible electroporation treatments in vegetal models

  • Castellví Fernández, Quim
  • Banús Cobo, Jaume
  • Ivorra Cano, Antoni, 1974-
Ablative techniques based on irreversible elec-troporation (IRE) have emerged as an effective cancer thera-py. In these treatments electrical pulses are delivered in order to induce irrecoverable damage to the cell membranes, thus, causing cell death. An interesting feature of electroporation treatments is the capability to predict shape and extension of lesions by means of mathematical simulations. Those predic-tion methods have been refined thought in-vivo experimental observations. Aiming at minimization of animal experiments, vegetal models have been used to easily observe the IRE out-comes. However, these observations are limited at the surface of the tissue. Here we present an improved method able to observe the inner parts of the tissue and therefore evaluate in three-dimensions the results of IRE using potatoes as vegetal models. The technique consists in using a dye solution to en-hance the IRE area in sliced potato tubers. After slice digitali-zation, the electroporated area is automatically identified and the resulting treated volume is calculated. In addition, a three-dimensional reconstruction of both healthy tissue and IRE volume is generated. The proposed evaluation technique was used to assess different pulse protocols outcomes. Numerical simulations had been carried out to compare the numerical predictions to the experimental observations. The obtained results show a clear match between experimental and simulat-ed volumes confirming the reliability of the proposed method., This work received financial support from the Spanish Government through grants TEC2010-17285 and TEC2014- 52383-C3 (TEC2014-52383-C3-2-R) and from the Europe-an Commission through the Marie Curie grant TAMIVIVE (256376).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Fast flow-through non-thermal pasteurization using constant radiofrequency electric fields

  • Ivorra Cano, Antoni, 1974-
  • González-Sosa, Jarold
  • Ruiz-Vargas, Albert
  • Arias, Guillem
Pulsed Electric Field technologies have captured the attention of researchers on food/npasteurization because of their non-thermal inactivation mechanism, which results in fresh-like/nproducts. Nevertheless, high voltage pulsing required by these technologies implies complex and costly/ngenerators. Here, as an alternative, it is proposed a method, partially inherited from research on cell/nelectroporation for gene transfection, in which the liquid to be treated flows at high speed through a/nminiature chamber where the electric field is permanently applied. In particular, it is proposed that the/nconstantly applied electric field consists of an AC signal (> 100 kHz) so that electrochemical byproducts/nare minimized. The method, while being compatible with batch processing, will allow use of/nlower voltages and will avoid the pulsation requirement. The proposal is accompanied by a numerical/nstudy and an in vitro study which demonstrate its feasibility, This work received financial support form the European Commission through the Marie Curie IRG grant/nTAMIVIVE (256376).
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Selective electroporation of liver tumor nodules by means of hypersaline infusion: a feasibility study

  • Castellví Fernández, Quim
  • Sánchez-Velázquez, Joan
  • Berjano, Enrique J.
  • Burdío Pinilla, Fernando
  • Ivorra Cano, Antoni, 1974-
Spread tumors in liver are not suitable to be treated with local treatments, such as conventional surgery or radiofrequency ablation, thus entailing a poor prognosis. Electroporation-based therapies imply the delivery of pulsed high electric fields and currently are performed in a local fashion using needle or plate electrodes. Here, however, it is proposed a novel electroporation paradigm in which field delivery is not local. All the tumor nodules will be selectively treated using large plate electrodes at both sides of the liver. By infusing an hypersaline solution of high electrical conductivity through the portal vein, the electrical conductivity of healthy tissues and tumor nodules will be made significantly different so that the electric field will be focused on the undesirable tissues. Numerical simulations were used to evaluate the feasibility of the proposed technique. In addition, an in vivo procedure was carried out to assess whether it is possible and practical to significantly modify the conductivity of the liver tissue by hypersaline infusion. Both the numerical simulations and the in vivo procedure provided encouraging results., This work received financial support from the Spanish “Plan Nacional de I+D+I del Ministerio de Ciencia e Innovación” Grants No. TEC2011-27133-C02-01,02 and TEC2010-17285 and from the European Commission through the Marie Curie grant TAMIVIVE (256376).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments

  • Trujillo Guillén, Macarena
  • Castellví Fernández, Quim
  • Burdío Pinilla, Fernando
  • Ivorra Cano, Antoni, 1974-
  • Andaluz, Anna
  • Sanchez Velazquez Patricia
  • Berjano, Enrique J.
Purpose: To assess the feasibility of a hybrid ablative technique based on applying electroporation (EP) pulses just before conducting radiofrequency ablation (RFA). The rationale was that the EP-induced reduction in blood perfusion could be sufficient to reduce the thermal sink effect and hence to increase the coagulation volume in comparison to that created exclusively by RFA./nMaterials and methods: Modeling study and in vivo experimental study. A Cool-tip RF applicator was used both for EP and RFA./nResults: Overall, the results did not show any synergy effect from using the hybrid technique. Applying EP pulses prior to RFA did not increase the coagulation zone obtained and the lesions were almost identical. Additional computer simulations provided an explanation for this; the effect of reducing blood perfusion by thermal damage during RFA completely masks the effect of reducing blood perfusion by EP. This is because both thermal damage and EP affect the same zone, i.e. the tissue around the electrode./nConclusions: Our computer modeling and in vivo experimental findings suggest that the combination of EP and RFA with monopolar applicators does not provide an additional benefit over the use of RFA alone., This work received financial support from the Spanish “Plan Nacional de I+D+I del Ministerio de Ciencia e Innovación” Grants No. TEC2011-27133-C02-01,02 and TEC2010-17285, from the European Commission through the Marie Curie IRG grant TAMIVIVE (256376) and from the Universitat Politècnica de València (INNOVA11-01-5502; and PAID-06-11 Ref. 1988). The linguistic revision of this paper was funded by the Universitat Politècnica de València, Spain.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Towards addressable wireless microstimulators based on electronic rectification of epidermically applied currents

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Electrical stimulation has been explored to restore/nthe capabilities of the nervous system in paralysis patients. This/narea of research and of clinical practice, known as Functional/nElectrical Stimulation, would greatly benefit from further/nminiaturization of implantable stimulators. To that end, we/nrecently proposed and demonstrated an innovative electrical/nstimulation method in which implanted microstimulators/noperate as rectifiers of bursts of innocuous high frequency/ncurrent supplied by skin electrodes, thus generating low/nfrequency currents capable of stimulating excitable tissues. A/ndiode could suffice in some applications but, in order to broaden/nthe method’s clinical applicability, we envision rectifiers with/nadvanced capabilities such as current control and/naddressability. We plan flexible thread-like implants (diameters/n< 300 μm) containing ASICs. As an intermediate stage, we are/ndeveloping macroscopic implants (diameters 2 mm) made of/noff-the-shelf components. Here we present a circuit which/nresponds to commands modulated within the high frequency/nbursts and which is able to deliver charge-balanced currents./nWe show that a number of these circuits can perform/nindependent stimulation of segments of an anesthetized/nearthworm following commands from a computer., AI’s research is supported by a Ramón y Cajal fellowship from the Spanish government and a Marie Curie grant (IRG 256376) from the European Commission. LBF’s research is supported by a scholarship from the UPF.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Anatomically realistic simulations of liver ablation by irreversible electroporation: impact of blood vessels on ablation volumes and undertreatment

  • Ivorra Cano, Antoni, 1974-
  • Qasrawi, Radwan Fayez Hasan
  • Silve, Louis Charles Arthur
  • Burdío Pinilla, Fernando
  • Abdeen, Ziad
Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible electroporation because of their influence on the electric field distribution. An anatomically realistic computer model of the liver and its vasculature within an abdominal section was employed, and blood vessels down to 0.4 mm in diameter were considered. In this model, the electric field distribution was simulated in a large series of scenarios (N = 576) corresponding to plausible percutaneous irreversible electroporation treatments by needle electrode pairs. These modeled treatments were relatively superficial (maximum penetration depth of the electrode within the liver = 26 mm) and it was ensured that the electrodes did not penetrate the vessels nor were in contact with them. In terms of total ablation volume, the maximum deviation caused by the presence of the vessels was 6%, which could be considered negligible compared to the impact by other sources of uncertainty. Sublethal field magnitudes were noticed around vessels covering volumes of up to 228 mm3. If in this model the blood was substituted by a liquid with a low electrical conductivity (0.1 S/m), the maximum volume covered by sublethal field magnitudes was 3.7 mm3 and almost no sublethal regions were observable. We conclude that undertreatment around blood vessels may occur in current liver ablation procedures by irreversible electroporation. Infusion of isotonic low conductivity liquids into the liver vasculature could prevent this risk., This work received financial support from the Spanish Government through grants TEC2010-17285, TEC2011-27133-C02, and TEC2014-52383-C3 (TEC2014-52383-C3-2) and from the European Commission through the Marie Curie IRG grant “TAMIVIVE” 256376.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

In vivo demonstration of addressable microstimulators powered by rectification of epidermically applied currents for miniaturized neuroprostheses

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Electrical stimulation is used in order to restore nerve mediated functions in patients with neurological disorders, but its applicability is constrained by the invasiveness of the systems required to perform it. As an alternative to implantable systems consisting of central stimulation units wired to the stimulation electrodes, networks of wireless microstimulators have been devised for fine movement restoration. Miniaturization of these microstimulators is currently hampered by the available methods for powering them. Previously, we have proposed and demonstrated a heterodox electrical stimulation method based on electronic rectification of high frequency current bursts. These bursts can be delivered through textile electrodes on the skin. This approach has the potential to result in an unprecedented level of miniaturization as no bulky parts such as coils or batteries are included in the implant. We envision microstimulators designs based on application-specific integrated circuits (ASICs) that will be flexible, thread-like (diameters <0.5 mm) and not only with controlled stimulation capabilities but also with sensing capabilities for artificial proprioception. We in vivo demonstrate that neuroprostheses composed of addressable microstimulators based on this electrical stimulation method are feasible and can perform controlled charge-balanced electrical stimulation of muscles. We developed miniature external circuit prototypes connected to two bipolar probes that were percutaneously implanted in agonist and antagonist muscles of the hindlimb of an anesthetized rabbit. The electronic implant architecture was able to/ndecode commands that were amplitude modulated on the high frequency (1 MHz) auxiliary current bursts. The devices were capable of independently stimulating the target tissues, accomplishing controlled dorsiflexion and plantarflexion joint movements. In addition, we/nnumerically show that the high frequency current bursts comply with safety standards both in terms of tissue heating and unwanted electro-stimulation. We demonstrate that addressable microstimulators powered by rectification of epidermically applied currents are feasible., This work was supported in part by the Ramón y Cajal fellowship (RYC-2009-04271) from the Spanish government and by a Marie Curie grant (IRG 256376) from the European Commission.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Charge counter for performing active charge-balance in miniaturized electrical stimulators

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Functional Electrical Stimulation (FES) has been explored in order to restore the capabilities of the nervous system in patients that suffer from paralysis. This area of research and of clinical practice greatly benefits from any technological improvement yielding miniaturization. In this regard, we recently proposed and demonstrated an innovative electrical stimulation method based on implanted microstimulators that operate as rectifiers of bursts of innocu-ous high frequency current supplied by skin electrodes, gener-ating low frequency currents that are capable of stimulating excitable tissues. We envision flexible ultrathin implants (di-ameters < 300 μm) containing ASICs that have advanced ca-pabilities, such as addressability and current control. As min-iaturization is the main aim of this method, the use of bulky DC-blocking capacitors (e.g. 10 μF) to accomplish zero net charge injection and avoid electrochemical tissue and electrode damage is highly inconvenient. As an alternative, here we present an active charge-balance method based on the use of a digital charge quantifier, whose operation is inspired in the functioning of the tipping bucket rain gauge. The system moni-tors the charge injection, matching the charge injected in the cathodal phase, with the charge injected in the anodal phase, generating a biphasic current waveform that adapts itself to possible current source mismatches. We have implemented a prototype built with discrete components which uses a capaci-tor of only 100 pF for the charge counter., AI’s research is supported by a Ramón y Cajal fellowship/nfrom the Spanish government and a Marie Curie grant/n(IRG 256376) from the European Commission. LBF’s research/nis supported by a scholarship from the UPF.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Proof of concept of a stimulator based on AC current rectification for neuroprosthetics

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: XXX Congreso Anual de la Sociedad Española de Ingeniería Biomédica, CASEIB 2012, celebrat a San Sebastián del 19 al 21 de novembre de 2012, For several years, researchers have developed techniques to replace and enhance the capabilities of our neural system by means of implantable electrical stimulation technologies. Even though important work has been done in this field, further progress must be accomplished in terms of miniaturization in order to ensure comfort, simpler surgical implantation procedures, and the capability of using multiple wireless smart stimulators for achieving more muscle recruitment. In the past, with the objective of accomplishing an unprecedented level of miniaturization, we have proposed the development of implantable stimulators that would act as rectifiers of AC current supplied by external electrodes. Here it is described the development and evaluation of an addressable stimulator based on discrete component technology as a proof-of-concept of the proposed method. This macroscopic version of the stimulator is capable of generating magnitude controlled bipolar pulses according to commands modulated in the AC current. Multiple evaluations were done to test the device, including DC current testing, in-vitro and in-vivo testing, concluding that the developed system is an effective proof-of-concept of the method proposed, being able to perform controlled electrical stimulation. Electrical current testing showed that anodal and cathodal currents were generated, and in-vivo testing showed the effective electrical stimulation of an anesthetized earthworm. It is concluded that the idea of developing smart rectifiers as implantable stimulators is feasible. This represents a first step towards the design of an implantable device with a miniaturization level without precedents., LBF’s Master’s degree was supported by Colfuturo - Colombia. AI’s research is currently supported by a Ramón y Cajal fellowship from the Spanish Ministry for Science and Innovation and a Marie Curie International Reintegration Grant (256376) from the European Commission.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Injectable rectifiers as microdevices for remote electrical stimulation: an alternative to inductive coupling

  • Ivorra Cano, Antoni, 1974-
  • Sacristán, Jordi
  • Baldi, Antonio
Presented at World Congress on Medical Physics and Biomedical Engineering; 2012 May 26-31; Beijing, China., Miniaturization of implantable medical elec-tronic devices is currently compromised by the available means for electrically powering them. Most common energy supply techniques for implants – batteries and inductive cou-plers – comprise bulky parts which, in most cases, are signifi-cantly larger than the circuitry they feed. For overcoming such miniaturization bottleneck in the case of implants for electrical stimulation, we recently proposed and demonstrated a method based on making the implants operate as rectifiers of bursts of high frequency current supplied by remote electrodes. In this way, low frequency current is generated locally around the implant and this low frequency current performs stimulation of excitable tissues whereas the high frequency current only causes innocuous heating. The present paper reports further progress in this technology. We first describe construction and functional test of an injectable stimulator consisting of a single miniature diode (300 μm × 300 μm × 600 μm) and two thin electrodes which is implanted trough a 19G needle into an anesthetized earthworm. We then propose a circuit architec-ture for implementing smart implants based on this technol-ogy. Both accomplishments are steps towards the implementa-tion of injectable addressable microsystems for neuroprosthetics. These systems based on the proposed tech-nology will look like short pieces of flexible thread rather than rigid capsules, as it was the case of previous miniature electri-cal stimulation implants. With currently available microelec-tronic techniques, very thin stimulation implants (diameter < 200 μm) are easily conceivable. This technology may be foun-dational to a broad range of new developments in the field of implantable medical devices with applications ranging from wound healing to nerve stimulation for pain relief. In addition, other non-medical devices could also emerge such as implant-able identification devices., AI’s research is supported by a Ramón y Cajal fellow-ship from the Spanish Ministry for Science and Innovation and a Marie Curie IRG from the European Commission
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Demonstration of 2 mm thick microcontrolled injectable stimulators based on rectification of high frequency current bursts

  • Becerra Fajardo, Laura
  • Schmidbauer, Marieluise
  • Ivorra Cano, Antoni, 1974-
Existing implantable stimulators use powering approaches that result in stiff and bulky systems or result in systems incapable of producing the current magnitudes required for neuromuscular stimulation. This hampers their use in neuroprostheses for paralysis. We previously demonstrated an electrical stimulation method based on electronic rectification of high frequency (HF) current bursts. The implants act as rectifiers of HF current that flows through the tissues by galvanic coupling, transforming this current into low frequency current capable of performing neuromuscular stimulation. Here we developed 2 mm thick, semi-rigid, injectable and addressable stimulators made of off-the-shelf components and based on this method. The devices were tested in vitro to illustrate how they are powered by galvanic coupling. In addition they were tried in an animal model to demonstrate their ability to perform controlled electrical stimulation. The implants were deployed by injection into two antagonist muscles of an anesthetized rabbit and were addressed resulting in independent isometric contractions. Low frequency currents of 2 mA were delivered by the implants. The HF currents are safe in terms of unwanted electrostimulation and tissue heating according to standards. This indicates that the proposed electrical stimulation method will allow unprecedented levels of miniaturization for neuroprostheses., LBF‘s research is supported by a PRC fellowship from the UPF. AI‘s research was supported by a Marie Curie grant (IRG 256376) from the European Commission.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Irreversible electroporation shows efficacy against pancreatic carcinoma without systemic toxicity in mouse models

  • José Segarra-Martínez, Anabel
  • Sobrevals, Luciano
  • Ivorra Cano, Antoni, 1974-
  • Fillat i Fonts, Cristina
Pancreatic Ductal Adenocarcinoma (PDAC) therapies show limited success./nIrreversible electroporation (IRE) is an innovative loco-regional therapy in which highvoltage pulses are applied to induce plasma membrane defects leading to cellular death. In the present study we evaluated the feasibility of IRE against PDAC. IRE/ntreatment exhibited significant antitumor effects and prolonged survival in mice with orthotopic xenografts. Extensive tumor necrosis, reduced tumor cell proliferation and disruption of microvessels were observed at different days post-IRE. Animals had transient increases in transaminases, amylase and lipase enzymes that normalized at/n24h post-IRE. These results suggest that IRE could be an effective treatment for locally advanced pancreatic tumors., This work was supported by the Spanish/nMinistry of Science and Innovation (MICINN), BIO2008-04692-C03-02/01 and received/npartial support from the Generalitat de Catalunya SGR091527. Anabel José was a/nrecipient of a FPU fellowship from the MICINN. Fillat’s group is also partially funded by/nCIBERER and by IIS10/00014 from Instituto de Salud Carlos III. Ivorra’s research is/ncurrently supported by a Ramón y Cajal fellowship from the Spanish Ministry for/nScience and Innovation and a Marie Curie IRG grant from the European Commission.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments

  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
  • Castellvi, Quim
  • Burdío, Fernando
  • Sánchez Velázquez, Patricia
  • Ivorra, Antoni
  • Andaluz, Anna
Purpose: The aim of this study was to assess the feasibility of a hybrid ablative technique based on applying electroporation (EP) pulses just before conducting radiofrequency ablation (RFA). The rationale was that the EP-induced reduction in blood perfusion could be sufficient to reduce the thermal sink effect and hence to increase the coagulation volume in comparison to that created exclusively by RFA. Materials and methods: A modelling study and in vivo experimental study were used. A Cool-tip RF applicator was used both for EP and RFA. Results: Overall, the results did not show any synergy effect from using the hybrid technique. Applying EP pulses prior to RFA did not increase the coagulation zone obtained and the lesions were almost identical. Additional computer simulations provided an explanation for this; the effect of reducing blood perfusion by thermal damage during RFA completely masks the effect of reducing blood perfusion by EP. This is because both thermal damage and EP affect the same zone, i.e. the tissue around the electrode. Conclusions: Our computer modelling and in vivo experimental findings suggest that the combination of EP and RFA with monopolar applicators does not provide an additional benefit over the use of RFA alone., This work received financial support from the Spanish 'Plan Nacional de I + D + I del Ministerio de Ciencia e Innovacion' Grant nos. TEC2011-27133-C02-01,02 and TEC2010-17285, from the European Commission through the Marie Curie IRG grant TAMIVIVE (256376) and from the Universitat Politecnica de Valencia (INNOVA11-01-5502; and PAID-06-11 Ref. 1988). The linguistic revision of this paper was funded by the Universitat Politecnica de Valencia, Spain. The authors alone are responsible for the content and writing of the paper.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Comparison of the effects of the repetition rate between microsecond and nanosecond pulses: electropermeabilization-induced electro-desensitization?

  • Silve, Aude
  • Guimerà Brunet, Antón
  • Al-Sakere, Bassim
  • Ivorra, Antoni
  • Mir, Lluis Maria
Applications of cell electropermeabilization are rapidly growing but basic concepts are still unclear. In particular, the impact of electric pulse repetition rate in the efficiency of permeabilization has not yet been understood., Peer reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Anatomically realistic simulations of liver ablation by irreversible electroporation: impact of blood vessels on ablation volumes and undertreatment

  • Ivorra Cano, Antoni, 1974-
  • Qasrawi, Radwan Fayez Hasan
  • Silve, Louis Charles Arthur
  • Burdío Pinilla, Fernando
  • Abdeen, Ziad
Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible electroporation because of their influence on the electric field distribution. An anatomically realistic computer model of the liver and its vasculature within an abdominal section was employed, and blood vessels down to 0.4 mm in diameter were considered. In this model, the electric field distribution was simulated in a large series of scenarios (N = 576) corresponding to plausible percutaneous irreversible electroporation treatments by needle electrode pairs. These modeled treatments were relatively superficial (maximum penetration depth of the electrode within the liver = 26 mm) and it was ensured that the electrodes did not penetrate the vessels nor were in contact with them. In terms of total ablation volume, the maximum deviation caused by the presence of the vessels was 6%, which could be considered negligible compared to the impact by other sources of uncertainty. Sublethal field magnitudes were noticed around vessels covering volumes of up to 228 mm3. If in this model the blood was substituted by a liquid with a low electrical conductivity (0.1 S/m), the maximum volume covered by sublethal field magnitudes was 3.7 mm3 and almost no sublethal regions were observable. We conclude that undertreatment around blood vessels may occur in current liver ablation procedures by irreversible electroporation. Infusion of isotonic low conductivity liquids into the liver vasculature could prevent this risk., This work received financial support from the Spanish Government through grants TEC2010-17285, TEC2011-27133-C02, and TEC2014-52383-C3 (TEC2014-52383-C3-2) and from the European Commission through the Marie Curie IRG grant “TAMIVIVE” 256376.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

3D Assessment of irreversible electroporation treatments in vegetal models

  • Castellví Fernández, Quim
  • Banús Cobo, Jaume
  • Ivorra Cano, Antoni, 1974-
Ablative techniques based on irreversible elec-troporation (IRE) have emerged as an effective cancer thera-py. In these treatments electrical pulses are delivered in order to induce irrecoverable damage to the cell membranes, thus, causing cell death. An interesting feature of electroporation treatments is the capability to predict shape and extension of lesions by means of mathematical simulations. Those predic-tion methods have been refined thought in-vivo experimental observations. Aiming at minimization of animal experiments, vegetal models have been used to easily observe the IRE out-comes. However, these observations are limited at the surface of the tissue. Here we present an improved method able to observe the inner parts of the tissue and therefore evaluate in three-dimensions the results of IRE using potatoes as vegetal models. The technique consists in using a dye solution to en-hance the IRE area in sliced potato tubers. After slice digitali-zation, the electroporated area is automatically identified and the resulting treated volume is calculated. In addition, a three-dimensional reconstruction of both healthy tissue and IRE volume is generated. The proposed evaluation technique was used to assess different pulse protocols outcomes. Numerical simulations had been carried out to compare the numerical predictions to the experimental observations. The obtained results show a clear match between experimental and simulat-ed volumes confirming the reliability of the proposed method., This work received financial support from the Spanish Government through grants TEC2010-17285 and TEC2014- 52383-C3 (TEC2014-52383-C3-2-R) and from the Europe-an Commission through the Marie Curie grant TAMIVIVE (256376).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Bidirectional communications in wireless microstimulators based on electronic rectification of epidermically applied currents

  • Ivorra Cano, Antoni, 1974-
  • Becerra Fajardo, Laura
Comunicació presentada a 7th Annual International IEEE/EMBS Conference on Neural Engineering, celebrada a Montpellier, França, del 22 al 24 d'abril de 2015., Functional Electrical Stimulation (FES) has been used in order to restore muscle functions in patients suffering from neurological disorders. This therapeutic approach benefits from technological improvements that yield miniaturization. We previously have proposed and demonstrated an innovative electrical stimulation method in which wireless implants act as rectifiers of innocuous high frequency (HF) currents. These currents are conductively supplied to the tissues where the/nimplants are located through external electrodes. Locally, the implants generate low frequency currents capable of stimulating excitable tissues. The method has the potential to enable unprecedented levels of miniaturization. The implant needs only two peripheral electrodes both for picking-up the HF current and for performing electrical stimulation. In addition, a tiny hybrid microcircuit, or a single integrated circuit, may integrate all the necessary electronic components. No bulky parts such as coils or batteries are required. We have demonstrated a number of circuit architectures for the implants with advanced capabilities such as digital addressability. In/nhere, we demonstrate that the proposed method also allows bidirectional communications between the implants and the external system that powers and governs them, enabling proprioception-like sensing capabilities that may be crucial for closed-loop FES systems. We demonstrate a scheme based on amplitude modulation and Manchester encoding., AI‟s research is supported by a Ramón y Cajal fellowship from the Spanish government and a Marie Curie grant (IRG 256376) from the European Commission. LBF‟s research is supported by a scholarship from the UPF.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Tumor growth delay by adjuvant alternating electric fields which appears non-thermally mediated

  • Castellví Fernández, Quim
  • Ginestà, Mireia M.
  • Capellá, Gabriel
  • Ivorra Cano, Antoni, 1974-
Delivery of the so-called Tumor Treatment Fields (TTFields) has been proposed as a cancer/ntherapy. These are low magnitude alternating electric fields at frequencies from 100 to 300 kHz/nwhich are applied continuously in a non-invasive manner. Electric field delivery may produce an/nincrease in temperature which cannot be neglected. We hypothesized that the reported results/nobtained by applying TTFields in vivo could be due to heat rather than to electrical forces as/npreviously suggested. Here it is presented an in vivo study in which pancreatic tumors/nsubcutaneously implanted in nude mice were treated for a week either with mild hyperthermia/n(41°C) or with TTFields (6 V/cm, 150 kHz) and tumor growth was assessed. Although the TTFields/napplied singly did not produce any significant effect, the combination with chemotherapy did show/na delay in tumor growth in comparison to animals treated only with chemotherapy (median relative/nreduction = 47%). We conclude that concomitant chemotherapy and TTFields delivery show a/nbeneficial impact on pancreatic tumor growth. Contrary to our hypothesis, this impact is nonrelated/nwith the induced temperature increase., This research was supported by project grants (AR00311 - MICINN-TEC2010-11182-E, SAF2012-/n33636, RTICCC RD12/0036/0031) from the Spanish government and in part by a Marie Curie grant/n(IRG 256376) from the European Commission and by the Generalitat de Catalunya (2009 SGR/n1356).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Irreversible electroporation shows efficacy against pancreatic carcinoma without systemic toxicity in mouse models

  • José Segarra-Martínez, Anabel
  • Sobrevals, Luciano
  • Ivorra Cano, Antoni, 1974-
  • Fillat i Fonts, Cristina
Pancreatic Ductal Adenocarcinoma (PDAC) therapies show limited success./nIrreversible electroporation (IRE) is an innovative loco-regional therapy in which highvoltage pulses are applied to induce plasma membrane defects leading to cellular death. In the present study we evaluated the feasibility of IRE against PDAC. IRE/ntreatment exhibited significant antitumor effects and prolonged survival in mice with orthotopic xenografts. Extensive tumor necrosis, reduced tumor cell proliferation and disruption of microvessels were observed at different days post-IRE. Animals had transient increases in transaminases, amylase and lipase enzymes that normalized at/n24h post-IRE. These results suggest that IRE could be an effective treatment for locally advanced pancreatic tumors., This work was supported by the Spanish/nMinistry of Science and Innovation (MICINN), BIO2008-04692-C03-02/01 and received/npartial support from the Generalitat de Catalunya SGR091527. Anabel José was a/nrecipient of a FPU fellowship from the MICINN. Fillat’s group is also partially funded by/nCIBERER and by IIS10/00014 from Instituto de Salud Carlos III. Ivorra’s research is/ncurrently supported by a Ramón y Cajal fellowship from the Spanish Ministry for/nScience and Innovation and a Marie Curie IRG grant from the European Commission.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Towards addressable wireless microstimulators based on electronic rectification of epidermically applied currents

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Electrical stimulation has been explored to restore/nthe capabilities of the nervous system in paralysis patients. This/narea of research and of clinical practice, known as Functional/nElectrical Stimulation, would greatly benefit from further/nminiaturization of implantable stimulators. To that end, we/nrecently proposed and demonstrated an innovative electrical/nstimulation method in which implanted microstimulators/noperate as rectifiers of bursts of innocuous high frequency/ncurrent supplied by skin electrodes, thus generating low/nfrequency currents capable of stimulating excitable tissues. A/ndiode could suffice in some applications but, in order to broaden/nthe method’s clinical applicability, we envision rectifiers with/nadvanced capabilities such as current control and/naddressability. We plan flexible thread-like implants (diameters/n< 300 μm) containing ASICs. As an intermediate stage, we are/ndeveloping macroscopic implants (diameters 2 mm) made of/noff-the-shelf components. Here we present a circuit which/nresponds to commands modulated within the high frequency/nbursts and which is able to deliver charge-balanced currents./nWe show that a number of these circuits can perform/nindependent stimulation of segments of an anesthetized/nearthworm following commands from a computer., AI’s research is supported by a Ramón y Cajal fellowship from the Spanish government and a Marie Curie grant (IRG 256376) from the European Commission. LBF’s research is supported by a scholarship from the UPF.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments

  • Trujillo Guillén, Macarena
  • Castellví Fernández, Quim
  • Burdío Pinilla, Fernando
  • Ivorra Cano, Antoni, 1974-
  • Andaluz, Anna
  • Sanchez Velazquez Patricia
  • Berjano, Enrique J.
Purpose: To assess the feasibility of a hybrid ablative technique based on applying electroporation (EP) pulses just before conducting radiofrequency ablation (RFA). The rationale was that the EP-induced reduction in blood perfusion could be sufficient to reduce the thermal sink effect and hence to increase the coagulation volume in comparison to that created exclusively by RFA./nMaterials and methods: Modeling study and in vivo experimental study. A Cool-tip RF applicator was used both for EP and RFA./nResults: Overall, the results did not show any synergy effect from using the hybrid technique. Applying EP pulses prior to RFA did not increase the coagulation zone obtained and the lesions were almost identical. Additional computer simulations provided an explanation for this; the effect of reducing blood perfusion by thermal damage during RFA completely masks the effect of reducing blood perfusion by EP. This is because both thermal damage and EP affect the same zone, i.e. the tissue around the electrode./nConclusions: Our computer modeling and in vivo experimental findings suggest that the combination of EP and RFA with monopolar applicators does not provide an additional benefit over the use of RFA alone., This work received financial support from the Spanish “Plan Nacional de I+D+I del Ministerio de Ciencia e Innovación” Grants No. TEC2011-27133-C02-01,02 and TEC2010-17285, from the European Commission through the Marie Curie IRG grant TAMIVIVE (256376) and from the Universitat Politècnica de València (INNOVA11-01-5502; and PAID-06-11 Ref. 1988). The linguistic revision of this paper was funded by the Universitat Politècnica de València, Spain.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Demonstration of 2 mm thick microcontrolled injectable stimulators based on rectification of high frequency current bursts

  • Becerra Fajardo, Laura
  • Schmidbauer, Marieluise
  • Ivorra Cano, Antoni, 1974-
Existing implantable stimulators use powering approaches that result in stiff and bulky systems or result in systems incapable of producing the current magnitudes required for neuromuscular stimulation. This hampers their use in neuroprostheses for paralysis. We previously demonstrated an electrical stimulation method based on electronic rectification of high frequency (HF) current bursts. The implants act as rectifiers of HF current that flows through the tissues by galvanic coupling, transforming this current into low frequency current capable of performing neuromuscular stimulation. Here we developed 2 mm thick, semi-rigid, injectable and addressable stimulators made of off-the-shelf components and based on this method. The devices were tested in vitro to illustrate how they are powered by galvanic coupling. In addition they were tried in an animal model to demonstrate their ability to perform controlled electrical stimulation. The implants were deployed by injection into two antagonist muscles of an anesthetized rabbit and were addressed resulting in independent isometric contractions. Low frequency currents of 2 mA were delivered by the implants. The HF currents are safe in terms of unwanted electrostimulation and tissue heating according to standards. This indicates that the proposed electrical stimulation method will allow unprecedented levels of miniaturization for neuroprostheses., LBF‘s research is supported by a PRC fellowship from the UPF. AI‘s research was supported by a Marie Curie grant (IRG 256376) from the European Commission.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Injectable rectifiers as microdevices for remote electrical stimulation: an alternative to inductive coupling

  • Ivorra Cano, Antoni, 1974-
  • Sacristán, Jordi
  • Baldi, Antonio
Presented at World Congress on Medical Physics and Biomedical Engineering; 2012 May 26-31; Beijing, China., Miniaturization of implantable medical elec-tronic devices is currently compromised by the available means for electrically powering them. Most common energy supply techniques for implants – batteries and inductive cou-plers – comprise bulky parts which, in most cases, are signifi-cantly larger than the circuitry they feed. For overcoming such miniaturization bottleneck in the case of implants for electrical stimulation, we recently proposed and demonstrated a method based on making the implants operate as rectifiers of bursts of high frequency current supplied by remote electrodes. In this way, low frequency current is generated locally around the implant and this low frequency current performs stimulation of excitable tissues whereas the high frequency current only causes innocuous heating. The present paper reports further progress in this technology. We first describe construction and functional test of an injectable stimulator consisting of a single miniature diode (300 μm × 300 μm × 600 μm) and two thin electrodes which is implanted trough a 19G needle into an anesthetized earthworm. We then propose a circuit architec-ture for implementing smart implants based on this technol-ogy. Both accomplishments are steps towards the implementa-tion of injectable addressable microsystems for neuroprosthetics. These systems based on the proposed tech-nology will look like short pieces of flexible thread rather than rigid capsules, as it was the case of previous miniature electri-cal stimulation implants. With currently available microelec-tronic techniques, very thin stimulation implants (diameter < 200 μm) are easily conceivable. This technology may be foun-dational to a broad range of new developments in the field of implantable medical devices with applications ranging from wound healing to nerve stimulation for pain relief. In addition, other non-medical devices could also emerge such as implant-able identification devices., AI’s research is supported by a Ramón y Cajal fellow-ship from the Spanish Ministry for Science and Innovation and a Marie Curie IRG from the European Commission
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

In vivo demonstration of addressable microstimulators powered by rectification of epidermically applied currents for miniaturized neuroprostheses

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Electrical stimulation is used in order to restore nerve mediated functions in patients with neurological disorders, but its applicability is constrained by the invasiveness of the systems required to perform it. As an alternative to implantable systems consisting of central stimulation units wired to the stimulation electrodes, networks of wireless microstimulators have been devised for fine movement restoration. Miniaturization of these microstimulators is currently hampered by the available methods for powering them. Previously, we have proposed and demonstrated a heterodox electrical stimulation method based on electronic rectification of high frequency current bursts. These bursts can be delivered through textile electrodes on the skin. This approach has the potential to result in an unprecedented level of miniaturization as no bulky parts such as coils or batteries are included in the implant. We envision microstimulators designs based on application-specific integrated circuits (ASICs) that will be flexible, thread-like (diameters <0.5 mm) and not only with controlled stimulation capabilities but also with sensing capabilities for artificial proprioception. We in vivo demonstrate that neuroprostheses composed of addressable microstimulators based on this electrical stimulation method are feasible and can perform controlled charge-balanced electrical stimulation of muscles. We developed miniature external circuit prototypes connected to two bipolar probes that were percutaneously implanted in agonist and antagonist muscles of the hindlimb of an anesthetized rabbit. The electronic implant architecture was able to/ndecode commands that were amplitude modulated on the high frequency (1 MHz) auxiliary current bursts. The devices were capable of independently stimulating the target tissues, accomplishing controlled dorsiflexion and plantarflexion joint movements. In addition, we/nnumerically show that the high frequency current bursts comply with safety standards both in terms of tissue heating and unwanted electro-stimulation. We demonstrate that addressable microstimulators powered by rectification of epidermically applied currents are feasible., This work was supported in part by the Ramón y Cajal fellowship (RYC-2009-04271) from the Spanish government and by a Marie Curie grant (IRG 256376) from the European Commission.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Proof of concept of a stimulator based on AC current rectification for neuroprosthetics

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: XXX Congreso Anual de la Sociedad Española de Ingeniería Biomédica, CASEIB 2012, celebrat a San Sebastián del 19 al 21 de novembre de 2012, For several years, researchers have developed techniques to replace and enhance the capabilities of our neural system by means of implantable electrical stimulation technologies. Even though important work has been done in this field, further progress must be accomplished in terms of miniaturization in order to ensure comfort, simpler surgical implantation procedures, and the capability of using multiple wireless smart stimulators for achieving more muscle recruitment. In the past, with the objective of accomplishing an unprecedented level of miniaturization, we have proposed the development of implantable stimulators that would act as rectifiers of AC current supplied by external electrodes. Here it is described the development and evaluation of an addressable stimulator based on discrete component technology as a proof-of-concept of the proposed method. This macroscopic version of the stimulator is capable of generating magnitude controlled bipolar pulses according to commands modulated in the AC current. Multiple evaluations were done to test the device, including DC current testing, in-vitro and in-vivo testing, concluding that the developed system is an effective proof-of-concept of the method proposed, being able to perform controlled electrical stimulation. Electrical current testing showed that anodal and cathodal currents were generated, and in-vivo testing showed the effective electrical stimulation of an anesthetized earthworm. It is concluded that the idea of developing smart rectifiers as implantable stimulators is feasible. This represents a first step towards the design of an implantable device with a miniaturization level without precedents., LBF’s Master’s degree was supported by Colfuturo - Colombia. AI’s research is currently supported by a Ramón y Cajal fellowship from the Spanish Ministry for Science and Innovation and a Marie Curie International Reintegration Grant (256376) from the European Commission.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Charge counter for performing active charge-balance in miniaturized electrical stimulators

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Functional Electrical Stimulation (FES) has been explored in order to restore the capabilities of the nervous system in patients that suffer from paralysis. This area of research and of clinical practice greatly benefits from any technological improvement yielding miniaturization. In this regard, we recently proposed and demonstrated an innovative electrical stimulation method based on implanted microstimulators that operate as rectifiers of bursts of innocu-ous high frequency current supplied by skin electrodes, gener-ating low frequency currents that are capable of stimulating excitable tissues. We envision flexible ultrathin implants (di-ameters < 300 μm) containing ASICs that have advanced ca-pabilities, such as addressability and current control. As min-iaturization is the main aim of this method, the use of bulky DC-blocking capacitors (e.g. 10 μF) to accomplish zero net charge injection and avoid electrochemical tissue and electrode damage is highly inconvenient. As an alternative, here we present an active charge-balance method based on the use of a digital charge quantifier, whose operation is inspired in the functioning of the tipping bucket rain gauge. The system moni-tors the charge injection, matching the charge injected in the cathodal phase, with the charge injected in the anodal phase, generating a biphasic current waveform that adapts itself to possible current source mismatches. We have implemented a prototype built with discrete components which uses a capaci-tor of only 100 pF for the charge counter., AI’s research is supported by a Ramón y Cajal fellowship/nfrom the Spanish government and a Marie Curie grant/n(IRG 256376) from the European Commission. LBF’s research/nis supported by a scholarship from the UPF.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Remote electrical stimulation by means of implanted rectifiers

  • Ivorra Cano, Antoni, 1974-
Miniaturization of active implantable medical devices is currently compromised by the available means for electrically/npowering them. Most common energy supply techniques for implants – batteries and inductive couplers – comprise bulky/nparts which, in most cases, are significantly larger than the circuitry they feed. Here, for overcoming such miniaturization/nbottleneck in the case of implants for electrical stimulation, it is proposed to make those implants act as rectifiers of high/nfrequency bursts supplied by remote electrodes. In this way, low frequency currents will be generated locally around the/nimplant and these low frequency currents will perform stimulation of excitable tissues whereas the high frequency currents/nwill cause only innocuous heating. The present study numerically demonstrates that low frequency currents capable of/nstimulation can be produced by a miniature device behaving as a diode when high frequency currents, neither capable of/nthermal damage nor of stimulation, flow through the tissue where the device is implanted. Moreover, experimental/nevidence is provided by an in vivo proof of concept model consisting of an anesthetized earthworm in which a commercial/ndiode was implanted. With currently available microelectronic techniques, very thin stimulation capsules (diameter/n,500 mm) deliverable by injection are easily conceivable., This author's research is currently supported by a Ramón y Cajal fellowship from the Spanish Ministry for Science and Innovation (RYC-2009-04271) and a Marie Curie International Reintegration Grant (256376 – “TAMIVIVE”) from the European Commission. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Impact of liver vasculature on electric field distribution during electroporation treatments: an anatomically realistic numerical study

  • Qasrawi, Radwan Fayez Hasan
  • Ivorra Cano, Antoni, 1974-
Electroporation is the phenomenon in which cell membrane permeability is increased by exposing the cell to high intensity electric fields. In living tissues, such permeabilization boost can be used in order to enhance the penetration of drugs or DNA plasmids or to destroy undesirable cells and it is typically performed by applying pulsed high voltages across needle electrodes. When used for ablation, and particularly in the context of liver tumors, it is often claimed that in contrast with thermal ablation techniques, electroporation is not severely impacted by the presence of large blood vessels because the heat sinking characteristic of those is not relevant for the electric field distribution. However, blood vessels do distort the electric field distribution because of their high inner conductivity. The goal of the study presented here is to numerically analyze the relevance of such distortion in a clinical scenario. An anatomically realistic model of the liver and its vasculature within an abdominal section was implemented. The blood vessels ranged from 0.3 to 6.3 mm in diameter and from 24 to 68.56 mm in length. A series of simulations with plausible random locations and depths (needle tips from 10 to 25mm within the liver) for the electrode pairs was conducted. Locations and depths were carefully verified so that the electrodes did not penetrate the vessels. The results were compared to those assuming that liver tissue is homogeneous. These comparisons indicate that volume error caused by neglecting the presence of vessels is less than 3%, which can be considered negligible if compared to other error sources. However, it was noticed that if the treated region comprises vessels or is very close to them, undertreated and over treated spots will appear around the vessels. Since undertreated spots may imply that tumor cells remain viable after treatment, caution is advised., This work has received financial support from the Spanish Government through grant TEC2010-17285 ―MEPVIVO‖ and from the European Commission through the Marie Curie IRG grant ―TAMIVIVE‖ (256376).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Selective electroporation of liver tumor nodules by means of hypersaline infusion: a feasibility study

  • Castellví Fernández, Quim
  • Sánchez-Velázquez, Joan
  • Berjano, Enrique J.
  • Burdío Pinilla, Fernando
  • Ivorra Cano, Antoni, 1974-
Spread tumors in liver are not suitable to be treated with local treatments, such as conventional surgery or radiofrequency ablation, thus entailing a poor prognosis. Electroporation-based therapies imply the delivery of pulsed high electric fields and currently are performed in a local fashion using needle or plate electrodes. Here, however, it is proposed a novel electroporation paradigm in which field delivery is not local. All the tumor nodules will be selectively treated using large plate electrodes at both sides of the liver. By infusing an hypersaline solution of high electrical conductivity through the portal vein, the electrical conductivity of healthy tissues and tumor nodules will be made significantly different so that the electric field will be focused on the undesirable tissues. Numerical simulations were used to evaluate the feasibility of the proposed technique. In addition, an in vivo procedure was carried out to assess whether it is possible and practical to significantly modify the conductivity of the liver tissue by hypersaline infusion. Both the numerical simulations and the in vivo procedure provided encouraging results., This work received financial support from the Spanish “Plan Nacional de I+D+I del Ministerio de Ciencia e Innovación” Grants No. TEC2011-27133-C02-01,02 and TEC2010-17285 and from the European Commission through the Marie Curie grant TAMIVIVE (256376).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Fast flow-through non-thermal pasteurization using constant radiofrequency electric fields

  • Ivorra Cano, Antoni, 1974-
  • González-Sosa, Jarold
  • Ruiz-Vargas, Albert
  • Arias, Guillem
Pulsed Electric Field technologies have captured the attention of researchers on food/npasteurization because of their non-thermal inactivation mechanism, which results in fresh-like/nproducts. Nevertheless, high voltage pulsing required by these technologies implies complex and costly/ngenerators. Here, as an alternative, it is proposed a method, partially inherited from research on cell/nelectroporation for gene transfection, in which the liquid to be treated flows at high speed through a/nminiature chamber where the electric field is permanently applied. In particular, it is proposed that the/nconstantly applied electric field consists of an AC signal (> 100 kHz) so that electrochemical byproducts/nare minimized. The method, while being compatible with batch processing, will allow use of/nlower voltages and will avoid the pulsation requirement. The proposal is accompanied by a numerical/nstudy and an in vitro study which demonstrate its feasibility, This work received financial support form the European Commission through the Marie Curie IRG grant/nTAMIVIVE (256376).