Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Laparoscopic partial splenectomy for giant cyst using a radiofrequency-assisted device: a case report

  • Quesada Diez, Rita
  • Poves Prim, José Ignacio
  • Iglesias Coma, Mar
  • Berjano, Enrique J.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Background: Although radiofrequency-assisted devices have sometimes been used in partial splenectomy, this is not a common technique. This report describes the first case of laparoscopic partial splenectomy using an RF-assisted device (Coolinside) which allows both coagulation and transection of the parenchyma and eventually the protective coagulation of the remnant side. Case presentation: A 27-year-old woman was found to have a giant hydatic cyst measuring 12.0 × 14.0 × 16.6 cm that mainly occupied the lower pole of the spleen and retroperitoneal space. The patient underwent a laparoscopic partial splenectomy using an RF-based device designed to accomplish both the coagulation and dissection of the splenic tissue. The estimated blood loss was less than 200 mL. Conclusions: Even though RF ablation has traditionally been used for hepatic parenchymal transection, it seems equally suited to partial splenectomy. This device seems to provide good results, minimizing blood loss during partial splenectomy; however, randomized trials will be necessary to see if the results are superior to those of other techniques., This work was partially supported by the Spanish “Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R and TEC2014-52383-C3-3-R).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Focused transhepatic electroporation mediated by hypersaline infusion through the portal vein in rat model: Preliminary results on differential conductivity

  • Pañella Vilamú, Clara, 1987-
  • Castellví Fernández, Quim
  • Moll, Xavier
  • Quesada Diez, Rita
  • Villanueva, Alberto
  • Iglesias Coma, Mar
  • Naranjo‐Hans, Dolores
  • Sánchez Velázquez, Patricia, 1985-
  • Andaluz, Anna
  • Grande Posa, Luís
  • Ivorra Cano, Antoni, 1974-
  • Burdío Pinilla, Fernando
Background. Spread hepatic tumours are not suitable for treatment either by surgery or conventional ablation methods. The aim of this study was to evaluate feasibility and safety of selectively increasing the healthy hepatic conductivity by the hypersaline infusion (HI) through the portal vein. We hypothesize this will allow simultaneous safe treatment of all nodules by irreversible electroporation (IRE) when applied in a transhepatic fashion. Material and methods. Sprague Dawley (Group A, n = 10) and Athymic rats with implanted hepatic tumour (Group B, n = 8) were employed. HI was performed (NaCl 20%, 3.8 mL/Kg) by trans-splenic puncture. Deionized serum (40 mL/Kg) and furosemide (2 mL/Kg) were simultaneously infused through the jugular vein to compensate hypernatremia. Changes in conductivity were monitored in the hepatic and tumour tissue. The period in which hepatic conductivity was higher than tumour conductivity was defined as the therapeutic window (TW). Animals were monitored during 1-month follow-up. The animals were sacrificed and selective samples were used for histological analysis. Results. The overall survival rate was 82.4% after the HI protocol. The mean maximum hepatic conductivity after HI was 2.7 and 3.5 times higher than the baseline value, in group A and B, respectively. The mean maximum hepatic conductivity after HI was 1.4 times higher than tumour tissue in group B creating a TW to implement selective IRE. Conclusions. HI through the portal vein is safe when the hypersaline overload is compensated with deionized serum and it may provide a TW for focused IRE treatment on tumour nodules., This work received financial support from the Spanish Government (Ministry of Economy and Competitiveness) under Grant TEC2014-52383-C3. The authors disclose no conflicts of interests.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis

  • Ivorra Cano, Antoni, 1974-
  • Sánchez Velázquez, Patricia, 1985-
  • Castellví Fernández, Quim
  • Villanueva, Alberto
  • Iglesias Coma, Mar
  • Quesada Diez, Rita
  • Pañella Vilamú, Clara, 1987-
  • Cáceres Aguilar, Mario
  • Dorcaratto, Dimitri
  • Andaluz, Anna
  • Moll, Xavier
  • Burdío, José M.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Irreversible electroporation (IRE) has recently gained in popularity as an ablative technique, however little is known about its oncological long-term outcomes. To determine the long-time survival of animals treated with a high dose of IRE and which histological changes it induces in tumoral tissue, IRE ablation was performed in forty-six athymic-nude mice with KM12C tumors implanted in the liver by applying electric current with different voltages (2000 V/cm, 1000 V/cm). The tumors were allowed to continue to grow until the animals reached the end-point criteria. Histology was harvested and the extent of tumor necrosis was semi-quantitatively assessed. IRE treatment with the 2000 V/cm protocol significantly prolonged median mouse survival from 74.3 ± 6.9 days in the sham group to 112.5 ± 15.2 days in the 2000 V/cm group. No differences were observed between the mean survival of the 1000 V/cm and the sham group (83.2 ± 16.4 days, p = 0.62). Histology revealed 63.05% ± 23.12 of tumor necrosis in animals of the 2000 V/cm group as compared to 17.50% ± 2.50 in the 1000 V/cm group and 25.6% ± 22.1 in the Sham group (p = 0.001). IRE prolonged the survival of animals treated with the highest electric field (2000 V/cm). The animals in this group showed significantly higher rate of tumoral necrosis., This research was supported by the spanish government under grants TEC2011-27133-c02 and TEC2010-17285, and by the spanish “plan estatal de investigación, desarrollo e innovación orientada a los retos de la sociedad” under grant TEC2014–52383-c3-r (TEC2014–52383-c3-2-r and TEC2014–52383-c3-3-r).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

  • Ewertowska, Elżbieta
  • Andaluz, Anna
  • Moll, Xavier
  • Aguilar, Adrià
  • Garcia, Felix
  • Fondevila, Dolors
  • Quesada Diez, Rita
  • Trujillo Guillén, Macarena
  • Burdío Pinilla, Fernando
  • Berjano, Enrique J.
introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a ∼10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered ∼5 W of power on an initial impedance of 308 ± 60 Ω. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under “Plan Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” (Grant TEC2014–52383–C3–R) and by the Spanish Ministerio de Ciencia, Innovación y Universidades under “Programa Estatal de I + D + i Orientada a los Retos de la Sociedad" (Grant: RTI2018-094357-B-C21 and –C22). Elżbieta Ewertowska has a Predoctoral Grant (BES-2015–073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain). Also funding was received from Secretaría de Estado de Investigación, Desarrollo e Innovación.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Dynamics of cell death after conventional IRE and H-FIRE treatments

  • Mercadal, Borja
  • Beitel White, Natalie
  • Aycock, Kenneth N.
  • Castellví Fernández, Quim
  • Davalos, Rafael Vidal
  • Ivorra Cano, Antoni, 1974-
High-frequency irreversible electroporation (H-FIRE) has emerged as an alternative to conventional irreversible electroporation (IRE) to overcome the issues associated with neuromuscular electrical stimulation that appear in IRE treatments. In H-FIRE, the monopolar pulses typically used in IRE are replaced with bursts of short bipolar pulses. Currently, very little is known regarding how the use of a different waveform affects the cell death dynamics and mechanisms. In this study, human pancreatic adenocarcinoma cells were treated with a typical IRE protocol and various H-FIRE schemes with the same energized time. Cell viability, membrane integrity and Caspase 3/7 activity were assessed at different times after the treatment. In both treatments, we identified two different death dynamics (immediate and delayed) and we quantified the electric field ranges that lead to each of them. While in the typical IRE protocol, the electric field range leading to a delayed cell death is very narrow, this range is wider in H-FIRE and can be increased by reducing the pulse length. Membrane integrity in cells suffering a delayed cell death shows a similar time evolution in all treatments, however, Caspase 3/7 expression was only observed in cells treated with H-FIRE., This work was supported by the Ministry of Economy and Competitiveness of Spain (Grant No. TEC2014-52383-C3-2-R), the Pancreatic Cancer Action Network (Grant No. 16-65-IANN) and Cures Within Reach (Grant No. PUJFSANY). Antoni Ivorra gratefully acknowledges financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Modeling methods for treatment planning in overlapping electroporation treatments

  • Perera Bel, Enric
  • Mercandal, Borja
  • Garcia-Sanchez, Tomas
  • González Ballester, Miguel Ángel, 1973-
  • Ivorra Cano, Antoni, 1974-
Objective: Irreversible electroporation (IRE) is a non thermal tissue ablation therapy which is induced by applying high voltage waveforms across electrode pairs. When multiple electrode pairs are sequentially used, the treatment volume (TV) is typically computed as the geometric union of the TVs of individual pairs. However, this method neglects that some regions are exposed to overlapping treatments. Recently, a model describing cell survival probability was introduced which effectively predicted TV with overlapping fields in vivo. However, treatment overlap has yet to be quantified. This study characterizes TV overlap in a controlled in vitro setup with the two existing methods which are compared to an adapted logistic model proposed here. Methods: CHO cells were immobilized in agarose gel. Initially, we characterized the electric field threshold and the cell survival probability for overlapping treatments. Subsequently, we created a 2D setup where we compared and validated the accuracy of the different methods in predicting the TV. Results: Overlap can reduce the electric field threshold required to induce cell death, particularly for treatments with low pulse number. However, it does not have a major impact on TV in the models assayed here, and all the studied methods predict TV with similar accuracy. Conclusion: Treatment overlap has a minor influence in the TV for typical protocols found in IRE therapies. Significance: This study provides evidence that the modeling method used in most pre-clinical and clinical studies seems adequate.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Avoiding nerve stimulation in irreversible electroporation: a numerical modeling study

  • Mercadal, Borja
  • Arena, Christopher B.
  • Davalos, Rafael Vidal
  • Ivorra Cano, Antoni, 1974-
Electroporation based treatments consist in applying one or multiple high voltage pulses to the tissues to be treated. As an undesired side effect, these pulses cause electrical stimulation of excitable tissues such as nerves and muscles. This increases the complexity of the treatments and may pose a risk to the patient. To minimize electrical stimulation during electroporation based treatments, it has been proposed to replace the commonly used monopolar pulses by bursts of short bipolar pulses. In the present study, we have numerically analyzed the rationale for such approach. We have compared different pulsing protocols in terms of their electroporation efficacy and their capability to trigger action potentials in nerves. For that, we have developed a modeling framework that combines numerical models of nerve fibers and experimental data on irreversible electroporation. Our results indicate that, by replacing the conventional relatively long monopolar pulses by bursts of short bipolar pulses, it is possible to ablate a large tissue region without triggering action potentials in a nearby nerve. Our models indicate that this is possible because, as the pulse length of these bipolar pulses is reduced, the stimulation thresholds raise faster than the irreversible electroporation thresholds. We propose that this different dependence on the pulse length is due to the fact that transmembrane charging for nerve fibers is much slower than that of cells treated by electroporation because of their geometrical differences., This work was supported by the Ministry of Economy and Competitiveness of Spain through the grant TEC2014-52383-C3-2-R. RVD’s research is supported by the National Institutes of Health under award number NIH 1R21 CA192041-01.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Pulsed radiofrequency for chronic pain: In vitro evidence of an electroporation mediated calcium uptake

  • Mercadal, Borja
  • Vicente García, Rubén, 1978-
  • Ivorra Cano, Antoni, 1974-
Pulsed radiofrequency (PRF) treatments for chronic pain consist in the delivery of a train of sinusoidal electric bursts to the targeted nerve. Despite numerous clinical evidence of its efficiency, the mechanism of action of PRF remains unclear. Since most of the reported biological effects of PRF can be initiated by a calcium influx into the neurons, we hypothesized that PRF may induce a mild electroporation effect causing a calcium uptake. To test this hypothesis, HEK-293 cells were exposed to PRF bursts and cytosolic calcium and Yo-Pro-1 uptake were monitored. After a single burst, calcium peaks were observed for electric fields above 480 V/cm while the uptake of Yo-pro-1 was insignificant. After a train of 120 bursts, the electric fields required to induce a calcium and Yo-pro-1 uptake decreased to 330 V/cm and 880 V/cm respectively. Calcium peaks were not detected when cells were treated in calcium free media. The temperature increase during the treatments was lower than 5 °C in all cases. Finally, the cell response for different burst frequencies and extracellular media conductivities correlated with the induced transmembrane voltage calculated with a numerical model. Our results support the hypothesis of an electroporation mediated calcium influx., This work was supported by the Ministry of Economy and Competitiveness of Spain through the grants TEC2014-52383-C3-2-R and SAF2014-52228-R. Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Anatomically realistic simulations of liver ablation by irreversible electroporation: impact of blood vessels on ablation volumes and undertreatment

  • Ivorra Cano, Antoni, 1974-
  • Qasrawi, Radwan Fayez Hasan
  • Silve, Louis Charles Arthur
  • Burdío Pinilla, Fernando
  • Abdeen, Ziad
Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible electroporation because of their influence on the electric field distribution. An anatomically realistic computer model of the liver and its vasculature within an abdominal section was employed, and blood vessels down to 0.4 mm in diameter were considered. In this model, the electric field distribution was simulated in a large series of scenarios (N = 576) corresponding to plausible percutaneous irreversible electroporation treatments by needle electrode pairs. These modeled treatments were relatively superficial (maximum penetration depth of the electrode within the liver = 26 mm) and it was ensured that the electrodes did not penetrate the vessels nor were in contact with them. In terms of total ablation volume, the maximum deviation caused by the presence of the vessels was 6%, which could be considered negligible compared to the impact by other sources of uncertainty. Sublethal field magnitudes were noticed around vessels covering volumes of up to 228 mm3. If in this model the blood was substituted by a liquid with a low electrical conductivity (0.1 S/m), the maximum volume covered by sublethal field magnitudes was 3.7 mm3 and almost no sublethal regions were observable. We conclude that undertreatment around blood vessels may occur in current liver ablation procedures by irreversible electroporation. Infusion of isotonic low conductivity liquids into the liver vasculature could prevent this risk., This work received financial support from the Spanish Government through grants TEC2010-17285, TEC2011-27133-C02, and TEC2014-52383-C3 (TEC2014-52383-C3-2) and from the European Commission through the Marie Curie IRG grant “TAMIVIVE” 256376.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Modeling liver electrical conductivity during hypertonic injection

  • Castellví Fernández, Quim
  • Sánchez Velázquez, Patricia, 1985-
  • Moll, Xavier
  • Berjano, Enrique J.
  • Andaluz, Anna
  • Burdío Pinilla, Fernando
  • Bijnens, Bart
  • Ivorra Cano, Antoni, 1974-
Metastases in the liver frequently grow as scattered tumor nodules which neither can be removed by surgical resection nor focally ablated. Previously, we have proposed a novel technique based on irreversible electroporation which may be able to simultaneously treat all nodules in the liver while sparing healthy tissue. The proposed technique requires increasing the electrical conductivity of healthy liver by injecting a hypersaline solution through the portal vein. Aiming to assess the capability of increasing the global conductivity of the liver by means of hypersaline fluids, here it is presented a mathematical model which estimates the NaCl distribution within the liver and the resulting conductivity change. The model fuses wellestablished compartmental pharmacokinetic models of the organ with saline injection models employed for resuscitation treatments and it considers changes in sinusoidal blood viscosity due to the hypertonicity of the solution. Here it is also described a pilot experimental study in pigs in which different volumes of NaCl 20% (from 100 to 200 ml) were injected through the portal vein at different flow rates (from 53 to 171 ml/min). The in vivo conductivity results fit those obtained by the model, both quantitatively and qualitatively, being able to predict the maximum conductivity with a 14.6% average relative error. The maximum conductivity value was 0.44 S/m which corresponds to increasing four times the mean basal conductivity (0.11 S/m). The results suggest that the presented model is well suited for predicting on liver conductivity changes during hypertonic saline injection., Spanish Government; contract/grant number: TEC2014-52383-C3-1-R, TEC2014-52383-C3-2-R and TEC2014-52383-C3-3-R
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Charge counter for performing active charge-balance in miniaturized electrical stimulators

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Functional Electrical Stimulation (FES) has been explored in order to restore the capabilities of the nervous system in patients that suffer from paralysis. This area of research and of clinical practice greatly benefits from any technological improvement yielding miniaturization. In this regard, we recently proposed and demonstrated an innovative electrical stimulation method based on implanted microstimulators that operate as rectifiers of bursts of innocu-ous high frequency current supplied by skin electrodes, gener-ating low frequency currents that are capable of stimulating excitable tissues. We envision flexible ultrathin implants (di-ameters < 300 μm) containing ASICs that have advanced ca-pabilities, such as addressability and current control. As min-iaturization is the main aim of this method, the use of bulky DC-blocking capacitors (e.g. 10 μF) to accomplish zero net charge injection and avoid electrochemical tissue and electrode damage is highly inconvenient. As an alternative, here we present an active charge-balance method based on the use of a digital charge quantifier, whose operation is inspired in the functioning of the tipping bucket rain gauge. The system moni-tors the charge injection, matching the charge injected in the cathodal phase, with the charge injected in the anodal phase, generating a biphasic current waveform that adapts itself to possible current source mismatches. We have implemented a prototype built with discrete components which uses a capaci-tor of only 100 pF for the charge counter., AI’s research is supported by a Ramón y Cajal fellowship/nfrom the Spanish government and a Marie Curie grant/n(IRG 256376) from the European Commission. LBF’s research/nis supported by a scholarship from the UPF.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Electrical modeling of the influence of medium conductivity on electroporation

  • Ivorra Cano, Antoni, 1974-
  • Villemejane, Julien
  • Mir, Lluis M.
Electroporation is the phenomenon in which cell membrane permeability is increased by exposing the cell to short high electric field pulses. Experimental data show that the amount of permeabilization depends on the conductivity of the extracellular medium. If medium conductivity decreases then it is necessary to deliver a pulse of larger field amplitude in order to achieve the same effect. Models that do not take into account the permeabilization effect on the membrane conductivity cannot reproduce qualitatively the experimental observations. Here we employ an exponential function for describing the strong dependence of membrane conductivity on transmembrane potential. Combining that model with numerical methods we demonstrate that the dependence on medium conductivity can be explained as being the result of increased membrane conductance due to electroporation. As experimentally observed, extracellular conductivities of about 1 and 0.1 S m−1 yield very similar results, however, for lower conductivities (<0.01 S m−1) the model predicts that significantly higher field magnitudes will be required to achieve the same amount of permeabilization., This work was supported by grants from: CNRS, Institute of cancerology Gustave-Roussy, University Paris Sud, INCa (National Institute of Cancer, France—contract number 07/3D1616/Doc-54-3NG-NC) and French National Agency (ANR) through Nanoscience and Nanotechnology program (Nanopulsebiochip no. ANR-08-NANO-024). AI’s research is currently supported by a Ramon y Cajal/nfellowship from the Spanish Ministry for Science and Innovation.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Impact of monopolar radiofrequency coagulation on intraoperative blood loss during liver resection: a prospective randomised controlled trial

  • Quesada Diez, Rita
  • Poves Prim, José Ignacio
  • Berjano, Enrique J.
  • Vilaplana, Carles
  • Andaluz, Anna
  • Moll, Xavier
  • Dorcaratto, Dimitri
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
PURPOSE: To evaluate the impact of using monopolar thermal coagulation based on radiofrequency (RF) currents on intraoperative blood loss during liver resection. MATERIALS AND METHODS: A prospective randomised controlled trial was planned. Patients undergoing hepatectomy were randomised into two groups. In the control group (n = 10), hemostasis was obtained with a combination of stitches, vessel-sealing bipolar RF systems, sutures or clips. In the monopolar radiofrequency coagulation (MRFC) group (n = 18), hemostasis was mainly obtained using an internally cooled monopolar RF electrode. RESULTS: No differences in demographic or clinical characteristics were found between groups. Mean blood loss during liver resection in the control group was more than twice that of the MRFC group (556 ± 471 ml vs. 225 ± 313 ml, p = .02). The adjusted mean bleeding/transection area was also significantly higher in the control group (7.0 ± 3.3 ml/cm2 vs. 2.8 ± 4.0 ml/cm2, p = .006). No significant differences were observed in the rate of complications between the groups. CONCLUSIONS: The findings suggest that the monopolar electrocoagulation created with an internally cooled RF electrode considerably reduces intraoperative blood loss during liver resection., This work was supported by a medical research grant from the Spanish Government (FIS PI080934) and by Spanish “Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” under Grant TEC2014–52383-C3-R (TEC2014–52383-C3–1-R and TEC2014–52383-C3–3-R)
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

EView: an electric field visualization web platform for electroporation-based therapies

  • Perera Bel, Enric
  • Yagüe, Carlos
  • Mercadal, Borja
  • Ceresa, Mario
  • Beitel White, Natalie
  • Davalos, Rafael Vidal
  • González Ballester, Miguel Ángel, 1973-
  • Ivorra Cano, Antoni, 1974-
Background and objectives: Electroporation is the phenomenon by which cell membrane permeability to ions and macromolecules is increased when the cell is briefly exposed to high electric fields. In electroporation-based treatments, such exposure is typically performed by delivering high voltage pulses across needle electrodes in tissue. For a given tissue and pulsing protocol, an electric field magnitude threshold exists that must be overreached for treatment efficacy. However, it is hard to preoperatively infer the treatment volume because the electric field distribution intricately depends on the electrodes’ positioning and length, the applied voltage, and the electric conductivity of the treated tissues. For illustrating such dependencies, we have created EView (https://eview.upf.edu), a web platform that estimates the electric field distribution for arbitrary needle electrode locations and orientations and overlays it on 3D medical images. Methods: A client-server approach has been implemented to let the user set the electrode configuration easily on the web browser, whereas the simulation is computed on a dedicated server. By means of the finite element method, the electric field is solved in a 3D volume. For the sake of simplicity, only a homogeneous tissue is modeled, assuming the same properties for healthy and pathologic tissues. The non-linear dependence of tissue conductivity on the electric field due to the electroporation effect is modeled. The implemented model has been validated against a state of the art finite element solver, and the server has undergone a heavy load test to ensure reliability and to report execution times. Results: The electric field is rapidly computed for any electrode and tissue configuration, and alternative setups can be easily compared. The platform provides the same results as the state of the art finite element solver (Dice = 98.3 ± 0.4%). During the high load test, the server remained responsive. Simulations are computed in less than 2 min for simple cases consisting of two electrodes and take up to 40 min for complex scenarios consisting of 6 electrodes. Conclusions: With this free platform we provide expert and non-expert electroporation users a way to rapidly model the electric field distribution for arbitrary electrode configurations., This work was supported by the Ministry of Economy and Competitiveness of Spain (grant number TEC2014-52383-C3-2-R), the María de Maeztu Units of Excellence Programme (grant number MDM-2015-0502) and by the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (grant number BES-2017-081164). Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Dependence of electroporation detection threshold on cell radius: an explanation to observations non compatible with Schwan’s equation model

  • Mercadal, Borja
  • Vernier, P. Thomas
  • Ivorra Cano, Antoni, 1974-
It is widely accepted that electroporation occurs when the cell transmembrane voltage induced by an external applied electric field reaches a threshold. Under this assumption, in order to trigger electroporation in a spherical cell, Schwan’s equation leads to an inversely proportional relationship between the cell radius and the minimum magnitude of the applied electric field. And, indeed, several publications report experimental evidences of an inverse relationship between the cell size and the field required to achieve electroporation. However, this dependence is not always observed or is not as steep as predicted by Schwan’s equation. The present numerical study attempts to explain these observations that do not fit Schwan’s equation on the basis of the interplay between cell membrane conductivity, permeability, and transmembrane voltage. For that, a single cell in suspension was modeled and the electric field necessary to achieve electroporation with a single pulse was determined according to two effectiveness criteria: a specific permeabilization level, understood as the relative area occupied by the pores during the pulse, and a final intracellular concentration of a molecule due to uptake by diffusion after the pulse, during membrane resealing. The results indicate that plausible model parameters can lead to divergent dependencies of the electric field threshold on the cell radius. These divergent dependencies were obtained through both criteria and using two different permeabilization models. This suggests that the interplay between cell membrane conductivity, permeability, and transmembrane voltage might be the cause of results which are noncompatible with the Schwan’s equation model., This work was supported by the Ministry of Economy and Competitiveness of Spain through Grant TEC2014-52383-C3-2-R. PTV received support from the Old Dominion University Frank Reidy Research Center for Bioelectrics and the Air Force Office of Scientific Research (FA9550-15-1-0517, FA9550-14-1-0123).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Endoluminal radiofrequency ablation of the main pancreatic duct is a secure and effective method to produce pancreatic atrophy and to achieve stump closure

  • Andaluz, Anna
  • Ewertowska, Elżbieta
  • Moll, Xavier
  • Aguilar, Adrià
  • García Arnas, Félix
  • Fondevila, Dolors
  • Quesada Diez, Rita
  • Berjano, Enrique J.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Radiofrequency energy has been used both experimentally and clinically to manage the pancreatic remnant after distal pancreatectomies. Our goal was to determine whether endoluminal radiofrequency (RF) ablation of the main pancreatic duct in large animals would be more efficient than glue occlusion as an exocrine pancreatic atrophy-inducing procedure. Thirty-four Landrace pigs were assigned to either the transpapilar (n = 16) or transection (n = 18) groups. The transection implied the pancreas neck was severed. In each of these groups the remaining distal pancreatic duct was occluded either by RF or by glue. In the transpapilar group complete atrophy was observed in all the RF cases, while atrophy was incomplete in all the members of the glue subgroup. The failure rate of the main pancreatic duct (usually expressed by a pseudocyst) in the transection groups was dramatically higher in the glue subgroup than the RF subgroups (9 out of 9 and 1 out of 9, respectively) and postoperative mortality occurred only in the glue subgroup (3 out of 9). These results show the superiority of endoluminal RF ablation over glue for main pancreatic duct occlusion, as seen by the degree of atrophy and fewer postoperative pancreatic fistulas., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under the “Plan Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” Grant TEC2014–52383–C3–R (TEC2014–52383–C3–1–R and TEC2014–52383–C3–3–R). Elzbieta Ewertowska has a Predoctoral Grant (BES-2015–073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Avoiding neuromuscular stimulation in liver irreversible electroporation using radiofrequency electric fields

  • Castellví Fernández, Quim
  • Mercadal, Borja
  • Moll, Xavier
  • Fondevila, Dolors
  • Andaluz, Anna
  • Ivorra Cano, Antoni, 1974-
Electroporation based treatments typically consist in applying high voltage dc pulses. As an undesired side effect, these dc pulses cause electrical stimulation of excitable tissues such as motor nerves. In the present in vivo study, it was explored the use of bursts of sinusoidal voltage in the frequency range from 50 kHz to 2 MHz to induce irreversible electroporation (IRE) whilst avoiding neuromuscular stimulation. Series of 100 dc pulses or sinusoidal bursts, both with an individual duration of 100 μs, were delivered to rabbit liver through thin needles in a monopolar electrode configuration and thoracic movements were recorded with an accelerometer. Tissue samples were harvested three hours after treatment and later postprocessed to determine the dimensions of the IRE lesions. Thermal damage due to Joule heating was ruled out via computer simulations. Sinusoidal bursts with a frequency equal or above 100 kHz did not cause thoracic movements and induced lesions equivalent to those obtained with conventional dc pulses when the applied voltage amplitude was sufficiently high. IRE efficacy dropped with increasing frequency. For 100 kHz bursts, it was estimated that the electric field threshold for IRE is about 1.4 kV/cm whereas that of dc pulses is about 0.5 kV/cm., This work was supported by the Ministry of Economy and Competitiveness of Spain through the grant TEC2014-52383-C3-R (TEC2014-52383-C3-2-R and TEC2014-52383-C3-3-R).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Electrochemical prevention of needle-tract seeding

  • Ivorra Cano, Antoni, 1974-
Needle-tract seeding refers to the implantation of tumor cells by contamination when instruments, such as biopsy needles, are employed to examine, excise or ablate a tumor. The incidence of this iatrogenic phenomenon is low but it entails serious consequences. Here, as a new method for preventing neoplasm seeding, it is proposed to cause electrochemical reactions at the instrument surface so that a toxic microenvironment is formed. In particular, the instrument shaft would act as the cathode and the tissues would act as the electrolyte in an electrolysis cell. By employing numerical models and experimental observations reported by researchers on Electrochemical Treatment of tumors, it is numerically showed that a sufficiently toxic environment of supraphysiological pH can be created in a few seconds without excessive heating. Then, by employing an ex vivo model consisting of meat pieces, validity of the conclusions provided by the numerical model concerning pH evolution is confirmed. Furthermore, a simplified in vitro model based on bacteria, instead of tumor cells, is implemented for showing the plausibility of the method. Depending on the geometry of the instrument, suitable current densities will probably range from about 5 mA/cm2 to 200 mA/cm2 and the duration of DC current delivery will range from a few seconds to a few minutes., AI’s research is currently supported by a Ramón y Cajal fellowship from the Spanish Ministry for Science and Innovation.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

  • Ewertowska, Elzbieta
  • Andaluz, Anna
  • Moll, Xavier
  • Adrià Aguilar
  • Garcia, Felix
  • Fondevila, Dolors
  • Quesada, Rita
  • Burdio, Fernando
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a similar to 10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered similar to 5 W of power on an initial impedance of 308 +/- 60 ohm. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy., This work was supported by the Spanish Ministerio de Economia, Industria y Competitividad under "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" (Grant TEC2014-52383-C3-R) and by the Spanish Ministerio de Ciencia, Innovacion y Universidades under "Programa Estatal de I+D+i Orientada a los Retos de la Sociedad" (Grant: RTI2018-094357-B-C21 and -C22). Elzbieta Ewertowska has a Predoctoral Grant (BES-2015-073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain). Also funding was received from Secretaria de Estado de Investigacion, Desarrollo e Innovacion.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Computer modelling of RF ablation in cortical osteoid osteoma: Assessment of the insulating effect of the reactive zone

  • Irastorza, Ramiro M.
  • Martel Villagran, Jose
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
Purpose: The aim was to study by computer simulations the insulating role of the reactive zone surrounding a cortical osteoid osteoma (OO) in terms of electrical and thermal performance during radiofrequency ablation (RFA). Material and methods: We modelled a cortical OO consisting of a nidus (10 mm diameter) enclosed by a reactive zone. The OO was near a layer of cortical bone 1.5 mm thick. Trabecular bone partially surrounds the OO and there was muscle around the cortical bone layer. We modelled RF ablations with a noncooled-tip 17-gauge needle electrode (300 s duration and 90 C target temperature). Sensitivity analyses were conducted assuming a reactive zone electrical conductivity value (rz) within the limits of the cortical and trabecular bone, i.e. 0.02 S/m and 0.087 S/m, respectively. In this way we were really modelling the different degrees of osteosclerosis associated with the reactive zone. Results: The presence of the reactive zone drastically reduced the maximum temperature reached outside it. The temperature drop was proportional to the thickness of the reactive zone: from 68 C when it was absent to 44 C when it is 7.5 mm thick. Higher nidus conductivity values (n) implied higher temperatures, while lower temperatures meant higher rz values. Changing rz from 0.02 S/m to 0.087 S/m reduced lesion diameters from 2.4 cm to 1.8 cm. Conclusions: The computer results suggest that the reactive zone plays the role of insulator in terms of reducing the temperature in the surrounding area. Keywor, This work was supported by a grant from the Agencia Nacional de Promocion Cientifica y Tecnologica de Argentina (Ref. PICT-2012-1201), and by the Spanish Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad under grant number TEC2014-52383-C3-R (TEC2014-52383-C3-1-R). The authors alone are responsible for the content and writing of the paper.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of the trabecular bone microstructure on measuring its thermal conductivity: A computer modeling-based study

  • Fajardo, Jesús E.
  • Carlevaro, C. Manuel
  • Vericat, Fernando
  • Irastorza, Ramiro Miguel
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] The objective of this work is to quantify the relation between the value of the effective thermal conductivity of trabecular bone and its microstructure and marrow content. The thermal conductivity of twenty bovine trabecular bone samples was measured prior to and after defatting at 37, 47, and 57 degrees C. Computer models were built including the microstructure geometry and the gap between the tissue and measurement probe. The thermal conductivity (k) measured was 0.39 +/- 0.06 W m(-1) K-1 at 37 degrees C, with a temperature dependence of + 0.2%degrees C-1. Replacing marrow by phosphate-buffered saline (defatting) increased both the computer simulations and measurement results by 0.04 W m(-1) K-1. The computer simulations showed that k increases by 0.02-0.04 W m(-1) K-1 when the model includes a gap filled by phosphate-buffered saline between the tissue and measurement probe. In the presence of microstructure and fatty red marrow, k varies by +/- 0.01 W m(-1) K-1 compared with the case considering matrix only, which suggests that there are no significant differences between cortical and trabecular bone in terms of k. The computer results showed that the presence of a gap filled by phosphate-buffered saline around the energy applicator changes maximum temperature by < 0.7 degrees C, while including the bone microstructure involved a variation of < 0.2 mm in the isotherm location. Future experimental studies on measuring the value of k involving the insertion of a probe into the bone through a drill hole should consider the bias found in the simulations. Thermal models based on a homogeneous geometry (i.e. ignoring the microstructure) could provide sufficient accuracy., This work was supported by a grant from the "Agencia Nacional de Promocion Cientfica y Tecnologica de Argentina" (Ref. PICT-2016-2303), by the National Scientific and Technical Research Council of Argentina (Grant PIO CONICET-UNAJ 0001), and by the Spanish "Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Numerical analysis of thermal impact of intramyocardial capillary blood flow during radiofrequency cardiac ablation

  • Pérez, Juan J|||0000-0001-8486-8699
  • González-Suárez, Ana|||0000-0002-1813-4176
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Purpose: The thermal effect of the intramyocardial blood perfusion on the size of lesions created by radiofrequency cardiac ablation (RFCA) has not been adequately studied to date. Our objective was to assess the impact of including this phenomenon in RFCA computer modelling in terms of the thermal lesion depth created.Methods: A computer model was built and computer simulations were conducted to assess the effect of including the blood perfusion term in the bioheat equation. This term mimics the intramyocardial blood flow (i.e., blood perfusion) in the cardiac wall at the site at which the RFCA is being conducted and hence represents a heat removing mechanism. When considered, blood perfusion rates ranged from 609 to 1719ml/min/kg. Two electrode design and modes were considered: a non-irrigated electrode with constant temperature mode and an irrigated electrode with constant power mode.Results: All the depths computed without including the blood perfusion term were larger than those that did include it, regardless of perfusion rate. The differences in lesion depth between ignoring and including blood perfusion increased over time; for a 60s RFCA they were 0.45 and 1mm for minimum and maximum perfusion rate, respectively. The differences were more or less independent of blood flow in the cardiac chamber, electrode type and ablation mode.Conclusions: The findings suggest that the heat-sink effect of blood perfusion should be taken into account in the case of ablations (>1minute) such as those conducted in RFCA of the ventricular wall., This work was supported by the Ministerio de Economia y Competitividad under "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" Grant "TEC2014- 52383-C3 [TEC2014-52383-C3-1-R]". A. Gonzalez-Suarez had a Postdoctoral Grant [APOSTD/2016/045] from the Generalitat Valenciana (Spain) and currently has a Postdoctoral Grant "Juan de la Cierva-formacion" [FJCI-2015-27202] supported by the Spanish Ministerio de Economia, Industria y Competitividad.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Computational modeling of internally cooled wet (ICW) electrodes for radiofrequency ablation: Impact of rehydration, thermal convection and electrical conductivity

  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Bon Corbín, José|||0000-0002-0457-9705
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Purpose: (1) To analyse rehydration, thermal convection and increased electrical conductivity as the three phenomena which distinguish the performance of internally cooled electrodes (IC) and internally cooled wet (ICW) electrodes during radiofrequency ablation (RFA), (2) Implement a RFA computer model with an ICW which includes these phenomena and (3) Assess their relative influence on the thermal and electrical tissue response and on the coagulation zone size. Methods: A 12-min RFA in liver was modelled using an ICW electrode (17G, 3cm tip) by an impedance-control pulsing protocol with a constant current of 1.5A. A model of an IC electrode was used to compare the ICW electrode performance and the computational results with the experimental results. Results: Rehydration and increased electrical conductivity were responsible for an increase in coagulation zone size and a delay (or absence) in the occurrence of abrupt increases in electrical impedance (roll-off). While the increased electrical conductivity had a remarkable effect on enlarging the coagulation zone (an increase of 0.74cm for differences in electrical conductivity of 0.31S/m), rehydration considerably affected the delay in roll-off, which, in fact, was absent with a sufficiently high rehydration level. In contrast, thermal convection had an insignificant effect for the flow rates considered (0.05 and 1mL/min). Conclusions: Computer results suggest that rehydration and increased electrical conductivity were mainly responsible for the absence of roll-off and increased size of the coagulation zone, respectively, and in combination allow the thermal and electrical performance of ICW electrodes to be modelled during RFA., This work was supported by the Government of Spain through the Spanish Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad under grant number TEC2014-52383-C3-R (TEC2014-52383-C3-1-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of applied voltage, duration and repetition frequency of RF pulses for pain relief on temperature spikes and electrical field: A computer modeling study

  • Ewertowska, Elzbieta
  • Mercadal, Borja
  • Muñoz, Víctor
  • Ivorra, Antoni
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Background: The thermal and electrical effects of pulsed radiofrequency (PRF) for pain relief can be controlled by modifying the characteristics of the RF pulses applied. Our goal was to evaluate the influence of such modifications on the thermal and electric performance in tissue. Methods: A computational model was developed to compare the temperature and electric field time courses in tissue between a standard clinical protocol (45 V pulses, 20ms duration, 2 Hz repetition frequency) and a new protocol (55 V pulses, 5ms duration, 5 Hz repetition frequency) with a higher applied electric field but a smaller impact on temperature alterations in tissue. The effect of including a temperature controller was assessed. Complementarily, an agar-based experimental model was developed to validate the methodology employed in the computer modelling. Results: The new protocol increased the electric field magnitude reached in the tissue by around +20%, without increasing the temperature. The temperature controller was found to be the fundamental factor in avoiding thermal damage to the tissue and reduced the total number of pulses delivered by around 67%. The experimental results matched moderately well with those obtained from a computer model built especially to mimic the experimental conditions. Conclusions: For the same delivered energy, the new protocol significantly increases the magnitude of the applied electric field, which may be the reason why it is clinically more effective in achieving pain relief., This work was supported by the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R and TEC2014-52383-C3-2-R). Elzbieta Ewertowska has a Predoctoral Grant (BES-2015-073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Modeling Liver Electrical Conductivity during Hypertonic Injection

  • Castellví, Quim
  • Sánchez Velazquez, Patricia
  • Moll, Xavier
  • Andaluz, Anna
  • Burdío, Fernando
  • Bijnens, Bart
  • Ivorra, Antoni
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Metastases in the liver frequently grow as scattered tumor nodules that neither can be removed by surgical resection nor focally ablated. Previously, we have proposed a novel technique based on irreversible electroporation that may be able to simultaneously treat all nodules in the liver while sparing healthy tissue. The proposed technique requires increasing the electrical conductivity of healthy liver by injecting a hypersaline solution through the portal vein. Aiming to assess the capability of increasing the global conductivity of the liver by means of hypersaline fluids, here, it is presented a mathematical model that estimates the NaCl distribution within the liver and the resulting conductivity change. The model fuses well-established compartmental pharmacokinetic models of the organ with saline injection models used for resuscitation treatments, and it considers changes in sinusoidal blood viscosity because of the hypertonicity of the solution. Here, it is also described a pilot experimental study in pigs in which different volumes of NaCl 20% (from 100 to 200mL) were injected through the portal vein at different flow rates (from 53 to 171 mL/minute). The in vivo conductivity results fit those obtained by the model, both quantitatively and qualitatively, being able to predict the maximum conductivity with a 14.6% average relative error. The maximum conductivity value was 0.44second/m, which corresponds to increasing 4 times the mean basal conductivity (0.11second/m). The results suggest that the presented model is well suited for predicting on liver conductivity changes during hypertonic saline injection., Ministry of Economy and Competitiveness of Spain, Grant/Award Number: TEC2014-52383-C3-1-R, TEC2014-52383-C3-2-R, TEC2014-52383-C3-3-R
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

An Analytical Solution for Radiofrequency Ablation with a Cooled Cylindrical Electrode

  • Romero-Méndez, Ricardo
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] We present an analytical solution to the electrothermal mathematical model of radiofrequency ablation of biological tissue using a cooled cylindrical electrode. The solution presented here makes use of the method of separation of variables to solve the problem. Green's functions are used for the handling of nonhomogeneous terms, such as effect of electrical currents circulation and the nonhomogeneous boundary condition due to cooling at the electrode surface. The transcendental equation for determination of eigenvalues of this problem is solved using Newton's method, and the integrals that appear in the solution of the problem are obtained by Simpson's rule. The solution obtained here has the possibility of handling different functional dependencies of the source term and nonhomogeneous boundary condition. The solution provides a tool to understand the physics of the problem, as it shows how the solution depends on different parameters, to provide mathematical tools for the design of surgical procedures and to validate other modeling techniques, such as the numerical methods that are frequently used to solve the problem., This work was supported by the Universidad Autonoma de San Luis Potosi (Mexico), which granted Ricardo Romero-Mendez a sabbatical leave to do research in the field of biomedical engineering, and the Government of Spain through the "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" (Grants TEC 2014-52383-C3-R and TEC 2014-52383-C3-1-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Endoluminal radiofrequency ablation of the main pancreatic duct is a secure and effective method to produce pancreatic atrophy and to achieve stump closure

  • Andaluz, Anna
  • Ewertowska, Elzbieta
  • Moll, Xavier
  • Aguilar, Adrià
  • García, Félix
  • Fondevila, Dolors
  • Quesada, Rita
  • Grande, Luís
  • Burdío, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Radiofrequency energy has been used both experimentally and clinically to manage the pancreatic remnant after distal pancreatectomies. Our goal was to determine whether endoluminal radiofrequency (RF) ablation of the main pancreatic duct in large animals would be more efficient than glue occlusion as an exocrine pancreatic atrophy-inducing procedure. Thirty-four Landrace pigs were assigned to either the transpapilar (n = 16) or transection (n = 18) groups. The transection implied the pancreas neck was severed. In each of these groups the remaining distal pancreatic duct was occluded either by RF or by glue. In the transpapilar group complete atrophy was observed in all the RF cases, while atrophy was incomplete in all the members of the glue subgroup. The failure rate of the main pancreatic duct (usually expressed by a pseudocyst) in the transection groups was dramatically higher in the glue subgroup than the RF subgroups (9 out of 9 and 1 out of 9, respectively) and postoperative mortality occurred only in the glue subgroup (3 out of 9). These results show the superiority of endoluminal RF ablation over glue for main pancreatic duct occlusion, as seen by the degree of atrophy and fewer postoperative pancreatic fistulas., This work was supported by the Spanish Ministerio de Economia, Industria y Competitividad under the "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R and TEC2014-52383-C3-3-R). Elzbieta Ewertowska has a Predoctoral Grant (BES-2015-073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Laparoscopic partial splenectomy for giant cyst using a radiofrequency-assisted device: a case report

  • Quesada, Rita
  • Poves, Ignasi
  • Iglesias, Mar
  • Grande, Luis
  • Burdío, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Background Although radiofrequency-assisted devices have sometimes been used in partial splenectomy, this is not a common technique. This report describes the first case of laparoscopic partial splenectomy using an RF-assisted device (Coolinside) which allows both coagulation and transection of the parenchyma and eventually the protective coagulation of the remnant side. Case presentation A 27-year-old woman was found to have a giant hydatic cyst measuring 12.0¿×¿14.0¿×¿16.6 cm that mainly occupied the lower pole of the spleen and retroperitoneal space. The patient underwent a laparoscopic partial splenectomy using an RF-based device designed to accomplish both the coagulation and dissection of the splenic tissue. The estimated blood loss was less than 200 mL. Conclusions Even though RF ablation has traditionally been used for hepatic parenchymal transection, it seems equally suited to partial splenectomy. This device seems to provide good results, minimizing blood loss during partial splenectomy; however, randomized trials will be necessary to see if the results are superior to those of other techniques., This work was partially supported by the Spanish“Programa Estatal deInvestigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R and TEC2014-52383-C3-3-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Irreversible electroporation of the liver: is there a safe limit to the ablation volume?

  • Sánchez-Velázquez, Patricia
  • Castellví, Quim
  • Villanueva, A
  • Quesada, Rita
  • Pañella, C.
  • Cáceres, Marta
  • Dorcaratto, Dimitri
  • Andaluz, Anna
  • Moll, X.
  • Burdío Pinilla, José Miguel
  • Grande, Luis
  • Ivorra, A.
  • Burdío Pinilla, Fernando
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
Irreversible electroporation is a fast-growing liver ablation technique. Although safety has been well documented in small ablations, our aim is to assess its safety and feasibility when a large portion of liver is ablated. Eighty-seven mice were subjected to high voltage pulses directly delivered across parallel plate electrodes comprising around 40% of mouse liver. One group consisted in 55 athymicnude, in which a tumor from the KM12C cell line was grown and the other thirty-two C57-Bl6 nontumoral mice. Both groups were subsequently divided into subsets according to the delivered field strength (1000V/cm, 2000V/cm) and whether or not they received anti-hyperkalemia therapy. Early mortality (less than 24hours post-IRE) in the 2000V/cm group was observed and revealed considerably higher mean potassium levels. In contrast, the animals subjected to a 2000V/cm field treated with the anti-hyperkalemia therapy had higher survival rates (OR=0.1, 95%CI=0.02–0.32, p<0.001). Early mortality also depended on the electric field magnitude of the IRE protocol, as mice given 1000V/cm survived longer than those given 2000V/cm (OR=4.7, 95%CI=1.8–11.8, p=0.001). Our findings suggest that ionic disturbances, mainly due to potassium alterations, should be warned and envisioned when large volume ablations are performed by IRE., This research was supported by the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3 (TEC2014-52383-C3-1-R, TEC2014-52383-C3-2-R, and TEC2014-52383-C3-3-R), and by the Spanish "Plan Nacional de I + D + i del Ministerio de Ciencia e Innovacion" under Grants TEC2011-27133-C02 and TEC2010-17285.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Computational Modeling of Open-Irrigated Electrodes for Radiofrequency Cardiac Ablation Including Blood Motion-Saline Flow Interaction

  • González-Suárez, Ana|||0000-0002-1813-4176
  • Berjano, Enrique|||0000-0002-3247-2665
  • Guerra, Jose M.
  • Gerardo-Giorda, Luca
[EN] Radiofrequency catheter ablation (RFCA) is a routine treatment for cardiac arrhythmias. During RFCA, the electrode-tissue interface temperature should be kept below 80°C to avoid thrombus formation. Open-irrigated electrodes facilitate power delivery while keeping low temperatures around the catheter. No computational model of an open-irrigated electrode in endocardial RFCA accounting for both the saline irrigation flow and the blood motion in the cardiac chamber has been proposed yet. We present the first computational model including both effects at once. The model has been validated against existing experimental results. Computational results showed that the surface lesion width and blood temperature are affected by both the electrode design and the irrigation flow rate. Smaller surface lesion widths and blood temperatures are obtained with higher irrigation flow rate, while the lesion depth is not affected by changing the irrigation flow rate. Larger lesions are obtained with increasing power and the electrode-tissue contact. Also, larger lesions are obtained when electrode is placed horizontally. Overall, the computational findings are in close agreement with previous experimental results providing an excellent tool for future catheter research., This work was supported in part by the Basque Government through the BERC 2014-2017 program and by Spanish Ministry of Economy and Competitiveness MINECO through the BCAM Severo Ochoa excellence accreditation SEV-2013-0323, and also by the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R) and Grant MTM201569992-R. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. This work was supported in part by the Basque Government through the BERC 2014-2017 program and by Spanish Ministry of Economy and Competitiveness MINECO through the BCAM Severo Ochoa excellence accreditation SEV-2013-0323, and also by the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R) and Grant MTM2015-69992-R
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Radiofrequency-induced heating versus mechanical stapler for pancreatic stump closure: in vivo comparative study

  • Burdío Pinilla, Fernando
  • Dorcaratto, dimitri
  • Hernandez, Lourdes
  • Andaluz, Anna
  • Moll, Xavier
  • Quesada-Diez, Rita
  • Poves, Ignasi
  • Grande, Luís
  • Cáceres, Marta
  • Berjano, Enrique|||0000-0002-3247-2665
Purpose: To assess the capacity of two methods of surgical pancreatic stump closure in terms of reducing the risk of pancreatic fistula formation (POPF): radiofrequencyinduced heating versus mechanical stapler. Materials and Methods: Sixteen pigs underwent a laparoscopic transection of the neck of the pancreas. Pancreatic anastomosis was always avoided in order to work with an experimental model prone to pancreatic fistula formation (POPF). Pancreatic stump closure was conducted either by stapler (ST Group, n=8) or radiofrequency energy (RF Group, n=8). Both groups were compared for incidence of POPF and histopathologic alterations of the pancreatic remnant. Results: Six animals (75%) in the ST Group and one (14%) in the RF Group were diagnosed of POPF (p=0.019). One animal in the RF Group and three animals in the ST Group had a pseudocyst in close contact with both pancreas stumps. On day 30 postoperative, almost complete atrophy of the exocrine distal pancreas was observed when the main pancreatic duct was efficiently sealed. Conclusions: Our findings suggest that RF-induced heating is more effective at closing the pancreatic stump than mechanical stapler and leads to the complete atrophy of the distal remnant pancreas., This work was supported by the Spanish 'Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad' under grant TEC2014-52383-C3-R (TEC2014-52383-C3-3-R). F.B., R.Q. and E.B. declare stock ownership in Apeiron Medical S.L., a company that has a license for the patent US 8.303.584.B2, on which the device tested in this study is based. The other authors report no conflict of interests or financial ties to disclose. The authors alone are responsible for the content and writing of the paper.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Should fluid dynamics be included in computer models of RF cardiac ablation by irrigated-tip electrodes?

  • González-Suárez, Ana|||0000-0002-1813-4176
  • Pérez, Juan J|||0000-0001-8486-8699
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Background: Although accurate modeling of the thermal performance of irrigated-tip electrodes in radiofrequency cardiac ablation requires the solution of a triple coupled problem involving simultaneous electrical conduction, heat transfer, and fluid dynamics, in certain cases it is difficult to combine the software with the expertise necessary to solve these coupled problems, so that reduced models have to be considered. We here focus on a reduced model which avoids the fluid dynamics problem by setting a constant temperature at the electrode tip. Our aim was to compare the reduced and full models in terms of predicting lesion dimensions and the temperatures reached in tissue and blood. Results: The results showed that the reduced model overestimates the lesion surface width by up to 5 mm (i.e. 70%) for any electrode insertion depth and blood flow rate. Likewise, it drastically overestimates the maximum blood temperature by more than 15 degrees C in all cases. However, the reduced model is able to predict lesion depth reasonably well (within 0.1 mm of the full model), and also the maximum tissue temperature (difference always less than 3 degrees C). These results were valid throughout the entire ablation time (60 s) and regardless of blood flow rate and electrode insertion depth (ranging from 0.5 to 1.5 mm). Conclusions: The findings suggest that the reduced model is not able to predict either the lesion surface width or the maximum temperature reached in the blood, and so would not be suitable for the study of issues related to blood temperature, such as the incidence of thrombus formation during ablation. However, it could be used to study issues related to maximum tissue temperature, such as the steam pop phenomenon., This work was supported by the Spanish Government under the "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" Grant "TEC2014-52383-C3 (TEC2014-52383-C3-1-R)". A. Gonzalez-Suarez has a Postdoctoral Grant "Juan de la Cierva-formacion" (FJCI-2015-27202) supported by the Spanish Ministerio de Economia, Industria y Competitividad. We also would like to appreciate the interesting comments by Dr. Oscar Camara about the limitations of the computational modeling.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A clinically-oriented computer model for radiofrequency ablation of hepatic tissue with internally cooled wet electrode

  • Ewertowska, Elzbieta
  • Quesada-Diez, Rita
  • Radosevic, A.
  • Andaluz, Anna
  • Moll, Xavier
  • García Arnás, F.
  • Burdío Pinilla, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
[EN] Purpose: To improve the computer modelling of radiofrequency ablation (RFA) by internally cooled wet (ICW) electrodes with added clinically oriented features. Methods: An improved RFA computer model by ICW electrode included: (1) a realistic spatial distribution of the infused saline, and (2) different domains to distinguish between healthy tissue, saline-infused tumour, and non-infused tumour, under the assumption that infused saline is retained within the tumour boundary. A realistic saline spatial distribution was obtained from an in vivo pig liver study. The computer results were analysed in terms of impedance evolution and coagulation zone (CZ) size, and were compared to the results of clinical trials conducted on 17 patients with the same ICW electrode. Results: The new features added to the model provided computer results that matched well with the clinical results. No roll-offs occurred during the 4-min ablation. CZ transversal diameter (4.10 +/- 0.19 cm) was similar to the computed diameter (4.16 cm). Including the tumour and saline infusion in the model involved (1) a reduction of the initial impedance by 10 - 20 ohm, (2) a delay in roll-off of 20 s and 70 - 100 s, respectively, and (3) 18 - 31% and 22 - 36% larger CZ size, respectively. The saline spatial distribution geometry was also seen to affect roll-off delay and CZ size. Conclusions: Using a three-compartment model and a realistic saline spatial distribution notably improves the match with the outcome of the clinical trials., This work was supported by the Spanish Ministerio de Economia, Industria y Competitividad under the "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R and TEC2014-52383-C3-3-R). Elzbieta Ewertowska has a Predoctoral Grant (BES-2015-073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Relation between Denaturation Time Measured by Optical Coherence Reflectometry and Thermal Lesion Depth during Radiofrequency Cardiac Ablation: Feasibility Numerical Study

  • González-Suárez, Ana|||0000-0002-1813-4176
  • Berjano, Enrique|||0000-0002-3247-2665
  • Herranz, David
  • Rubio-Guivernau, Jose L.
  • Margallo-Balbás, Eduardo
[EN] Background/Objective Radiofrequency (RF) catheter ablation is a minimally invasive medical procedure used to thermally destroy the focus of cardiac arrhythmias. Novel optical techniques are now being integrated into RF catheters in order to detect the changes in tissue properties. Loss of birefringence due to fiber denaturation at around 70°C is related to changes in accumulated phase retardation and can be measured by polarization¿sensitive optical coherence reflectometry (PS¿OCR). Since irreversible thermal lesions are produced when the tissue reaches 50°C, our goal was to seek the mathematical relationship between both isotherms. Materials and Methods A two¿dimensional model based on a coupled electric¿thermal problem was built and solved using the finite element method. The model consisted of cardiac tissue, blood, and a non¿irrigated electrode with a sensor embedded in its tip to maintain a specific target electrode temperature. Computer simulations were conducted by varying the tissue characteristics. Lesion depth was estimated by the 50°C isotherm, while the denaturation time (TD) was taken as the time at which the 70°C isotherm reached a depth of 0.75¿mm (which corresponds to the optical depth reached by PS¿OCR technology). Results A strong correlation (R2¿>¿0.83) was found between TD and lesion depth and an even stronger correlation (R2¿>¿0.96) was found between TD and the time required to achieve a specific lesion depth. For instance, the ablation time required to ensure a minimum lesion depth of 3¿mm was 1.33¿×¿TD¿+¿3.93¿×¿seconds. Conclusions The computer results confirmed the strong relationship between denaturation time and lesion depth and suggest that measuring denaturation time by PS¿OCR could provide information on the ablation time required to reach a specific lesion depth. Lasers Surg. Med. 50:222¿229, 2018. © 2017 Wiley Periodicals, Inc., Contract grant sponsor: Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" Grant; Contract grant number: TEC2014-52383-C3 (TEC2014-52383-C3-1-R); Contract grant sponsor: Juan de la Cierva-formacion; Contract grant number: FJCI-2015-27202; Contract grant sponsor: Spanish Ministerio de Economia, Industria y Competitividad; Contract grant sponsor: United States Air Force Office of Scientific Research.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Impact of monopolar radiofrequency coagulation on intraoperative blood loss during liver resection: a prospective randomised controlled trial

  • Quesada-Diez, Rita
  • Poves, Ignasi
  • Vilaplana, Carles
  • Andaluz, Anna
  • Moll, Xavier
  • Dorcaratto, Dimitri
  • Grande, Luís
  • Burdío Pinilla, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
Purpose: To evaluate the impact of using monopolar thermal coagulation based on radiofrequency (RF) currents on intraoperative blood loss during liver resection. Materials and methods: A prospective randomized controlled trial was planned. Patients undergoing hepatectomy were randomized into two groups. In the Control group (n=10), hemostasis was obtained with a combination of stitches, vessel-sealing bipolar RF systems, sutures or clips. In the monopolar radiofrequency coagulation (MRFC) group (n=18), hemostasis was mainly obtained using an internally cooled monopolar RF electrode. Results: No differences in demographic or clinical characteristics were found between groups. Mean blood loss during liver resection in the Control group was more than twice that of the MRFC group (556±471 ml vs. 225±313 ml, p=0.02). The adjusted mean bleeding/transection area was also significantly higher in the Control group (7.0±3.3 ml/cm2 vs. 2.8±4.0 ml/cm2 , p=0.006). No significant differences were observed in the rate of complications between the groups. Conclusions: The findings suggest that the monopolar electrocoagulation created with an internally-cooled RF electrode considerably reduces intraoperative blood loss during liver resection., This work was supported by a medical research grant from the Spanish Government (FIS PI080934) and by Spanish "Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R and TEC2014-52383-C3-3-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Computer modeling of an impedance-controlled pulsing protocol for RF tumor ablation with a cooled electrode

  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Bon Corbín, José|||0000-0002-0457-9705
  • Berjano, Enrique|||0000-0002-3247-2665
  • Rivera Ortun, María José
  • Burdio, Fernando
[EN] Purpose: To develop computer models to mimic the impedance-controlled pulsing protocol implemented in radiofrequency (RF) generators used for clinical practice of radiofrequency ablation (RFA), and to assess the appropriateness of the models by comparing the computer results with those obtained in previous experimental studies.Methods: A 12-min RFA was modelled using a cooled electrode (17G, 3cm tip) inserted in hepatic tissue. The short (transverse) diameter of the coagulation zone was assessed under in vivo (with blood perfusion (BP) and considering clamping) and ex vivo (at 21 degrees C) conditions. The computer results obtained by programming voltage pulses were compared with current pulses.Results: The differences between voltage and current pulses were noticeable: using current instead of voltage allows larger coagulation zones to be created, due to the higher energy applied by current pulses. If voltage pulses are employed the model can accurately predict the number of roll-offs, although the waveform of the applied power is clearly not realistic. If current voltages are employed, the applied power waveform matches well with those reported experimentally, but there are significantly fewer roll-offs. Our computer results were overall into the ranges of experimental ones.Conclusions: The proposed models reproduce reasonably well the electrical-thermal performance and coagulation zone size obtained during an impedance-controlled pulsing protocol., This work was supported by the Spanish Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad under grant number TEC2014-52383-C3-R (TEC2014-52383-C3-1-R). The authors alone are responsible for the content and writing of the paper.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Electrical-thermal analytical modeling of monopolar RF thermal ablation of biological tissues: determining the circumstances under which tissue temperature reaches a steady state

  • López Molina, Juan Antonio
  • Berjano, Enrique|||0000-0002-3247-2665
  • Rivera Ortun, María José
[EN] It has been suggested that during RF thermal ablation of biological tissue the thermal lesion could reach an equilibrium size after 1-2 minutes. Our objective was to determine under which circumstances of electrode geometry (needle-like vs. ball-tip), electrode type (dry vs. cooled) and blood perfusion the temperature will reach a steady state at any point in the tissue. We solved the bioheat equation analytically both in cylindrical and spherical coordinates and the resultant limit temperatures were compared. Our results demonstrate mathematically that tissue temperature reaches a steady value in all cases except for cylindrical coordinates without the blood perfusion term, both for dry and cooled electrodes, where temperature increases infinitely. This result is only true when the boundary condition far from the active electrode is considered to be at infinitum. In contrast, when a finite and sufficiently large domain is considered, temperature reaches always a steady state., This work received financial support from the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Thermal Latency adds to Lesion Depth after Application of High-Power Short-Duration Radiofrequency Energy: Results of a computer-modeling study

  • Irastorza, Ramiro Miguel
  • D Avila, Andre
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Introduction: The use of ultra-short RF pulses could achieve greater lesion depth immediately after the application of the pulse due to thermal latency. Methods and results: A computer model of irrigated-catheter RF ablation was built to study the impact of thermal latency on the lesion depth. The results showed that the shorter the RF pulse duration (keeping energy constant), the greater the lesion depth during the cooling phase. For instance, after a 10-second pulse, lesion depth grew from 2.05 mm at the end of the pulse to 2.39 mm (17%), while after an ultra-short RF pulse of only 1 second the extra growth was 37% (from 2.22 to 3.05 mm). Importantly, short applications resulted in deeper lesions than long applications (3.05 mm vs. 2.39 mm, for 1-and 10-second pulse, respectively). While shortening the pulse duration produced deeper lesions, the associated increase in applied voltage caused overheating in the tissue: temperatures around 100 degrees C were reached at a depth of 1 mm in the case of 1-and 5-second pulses. However, since the lesion depth increased during the cooling period, lower values of applied voltage could be applied in short durations in order to obtain lesion depths similar to those in longer durations while avoiding overheating. Conclusion: The thermal latency phenomenon seems to be the cause of significantly greater lesion depth after short-duration high-power RF pulses. Balancing the applied total energy when the voltage and duration are changed is not the optimal strategy since short pulses can also cause overheating., This work was supported by the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3 (TEC2014-52383-C3-1-R) and by the National Scientific and Technical Research Council - Argentina "Proyecto de Investigacion Orientado" (PIOCONICET-UNAJ 0001).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Can Fat Deposition After Myocardial Infarction Alter the Performance of RF Catheter Ablation of Scar-Related Ventricular Tachycardia?: Results from a Computer Modeling Study

  • Pérez, Juan J
  • D&apos;Avila, Andre
  • Aryana, Arash
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
Effect of Fat Deposition on the Performance in RF Ablation IntroductionThe outcomes of catheter ablation of scar-mediated ventricular tachycardia (VT) remain far from perfect. The presence of fat as a component of the underlying substrate for scar-mediated VT could be relevant since this entity can seriously impede the passage of RF current due to its low electrical conductivity. Methods and ResultsComputer models of RF ablation were built in order to investigate the means by which the spatial heterogeneity of different tissues represented within the ventricular infarct zone, including the viable myocardium, fibrous tissue, and fat, could influence temperature distributions during RF ablation. The results demonstrated that spatial distributions of different tissue types significantly alter the density of electrical current largely as a result of fat impeding the passage of current. However, the thermal lesions appear minimally unaffected by this phenomenon, with variations in depth of approximate to 1 mm. ConclusionWhile during RF ablation of scar-related ventricular tachycardia differences in tissue characteristics may affect the density of electrical current on a small-scale, overall this does not appear to significantly impact the size of the created thermal lesions., This work was supported by the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3 (TEC2014-52383-C3-1-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

RF-Energized Intracoronary Guidewire to Enhance Bipolar Ablation of the Interventricular Septum: In-silico Feasibility Study

  • Pérez, Juan J|||0000-0001-8486-8699
  • González-Suárez, Ana|||0000-0002-1813-4176
  • Berjano, Enrique|||0000-0002-3247-2665
  • D Avila, Andre
[EN] Purpose: Although bipolar radiofrequency (RF) ablation (RFA) is broadly used to eliminate ventricular tachycardias in the interventricular septum wall, it can fail to create transmural lesions in thick ventricular walls. To solve this problem, we explored whether an RF-energised guidewire inserted into the ventricular wall would enhance bipolar RFA in the creation of transmural lesions through the ventricular wall.Methods: We built three-dimensional computational models including two irrigated electrodes placed on opposing sides of the interventricular septum and a metal guidewire inserted into the septum. Computer simulations were conducted to compare the temperature distributions obtained with two ablation modes: bipolar mode (RF power delivered between both irrigated electrode) and time-division multiplexing (TDM) technique, which consists of activating the bipolar mode for 90% of the time and applying RF power between the guidewire and both irrigated electrodes during the remaining time.Results: The TDM technique was the most suitable in terms of creating wider lesions through the entire ventricular wall, avoiding the hour-glass shape of thermal lesions associated with the bipolar mode. This was especially apparent in the case of thick walls (15mm). Furthermore, the TDM technique was able to create transmural lesions even when the guidewire was displaced from the midplane of the wall.Conclusions: An RF-energised guidewire could enhance bipolar RFA by allowing transmural lesions to be made through thick ventricular walls. However, the safety of this new approach must be assessed in future pre-clinical studies, especially in terms of the risk of stenosis and its clinical impact., This work was supported by the Spanish Ministerio de Economia, Industria y Competitividad under "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" Grant "TEC2014-52383-C3 (TEC2014-52383-C3-1-R)". A. Gonzalez-Suarez has a "Juan de la Cierva-formacion" Postdoctoral Grant (FJCI-2015-27202) supported by the Spanish Ministerio de Economia, Industria y Competitividad, Secretaria de Estado de Investigacion, Desarrollo e Innovacion.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Long-term evolution of acinar-to-ductal metaplasia and b-cell mass after radiofrequency-assisted transection of the pancreas in a controlled large animal model

  • Quesada-Diez, Rita
  • Andaluz, Anna
  • Cáceres, Marta
  • Moll, Xavier
  • Iglesias, Mar
  • Dorcaratto, dimitri
  • Poves, Ignasi
  • Grande, Luís
  • Burdio Pinilla, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
Background: Pancreatic duct ligation (PDL) has been used as a model of chronic pancreatitis and as a model to increase β-cell mass. However, studies in mice have demonstrated acinar regeneration after PDL, questioning the long-term validity of the model. We aim to elucidate whether RF-assisted transection (RFAT) of the main pancreatic duct is a reliable PDL model, both in short (ST, 1-month) and long-term (LT, 6-months) follow-ups. Methods: Eleven pigs were subjected to RFAT. Biochemical (serum/peripancreatic amylase and glucose) and histological changes (including a semiautomatic morphometric study of over 1000 images/pancreas and IHC analysis) were evaluated after ST or LT follow-up and also in fresh pancreas specimens that were used as controls for 1 (n=4) and 6 months (n=6). Results: The distal pancreas in the ST was characterized by areas of acinar-to-ductal metaplasia (56%) which were significantly reduced at LT (21%) by fibrotic replacement and adipose tissue. The endocrine mass showed a normal increase. Conclusion: RFAT in the pig seems to be an appropriate PDL model without restoration of pancreatic drainage or reduction of endocrine mass., "This work was supported by the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3 (TEC2014-52383-C3-3-R). RQ, EB, FB declare stock ownership in Apeiron Medical S.L., a company that has a license for the patent US 8.303.584.B2, on which the device have been employed.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Comparative Analysis of Different Methods of Modeling the Thermal Effect of Circulating Blood Flow During RF Cardiac Ablation

  • González-Suárez, Ana|||0000-0002-1813-4176
  • Berjano, Enrique|||0000-0002-3247-2665
Our aim was to compare the different methods of modeling the effect of circulating blood flow on the thermal lesion dimensions created by radio frequency (RF) cardiac ablation and on the maximum blood temperature. Computational models were built to study the temperature distributions and lesion dimensions created by a nonirrigated electrode by two RF energy delivery protocols (constant voltage and constant temperature) under high and low blood flow conditions. Four methods of modeling the effect of circulating blood flow on lesion dimensions and temperature distribution were compared. Three of them considered convective coeffi- cients at the electrode–blood and tissue–blood interfaces to model blood flow: 1) without including blood as a part of the domain; 2) constant electrical conductivity of blood; and 3) temperaturedependent electrical conductivity of blood (+2%/°C). Method 4) included blood motion and was considered to be a reference method for comparison purposes. Only Method 4 provided a realistic blood temperature distribution. The other three methods predicted lesion depth values similar to those of the reference method (differences smaller than 1 mm), regardless of ablation mode and blood flow conditions. Considering the aspects of lesion size and maximum temperature reached in blood and tissue, Method 2 seems to be the most suitable alternative to Method 4 in order to reduce the computational complexity. Our findings could have an important implication in future studies of RF cardiac ablation, in particular, in choosing the most suitable method to model the thermal effect of circulating blood., This work was supported in part by the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3 (TEC2014-52383-C3-1-R) and also by the Basque Government through the BERC 2014-2017 program and by Spanish Ministry of Economy and Competitiveness MINECO: BCAM Severo Ochoa excellence accreditation SEV-2013-0323. Asterisk indicates corresponding author.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

How coagulation zone size is underestimated in computer modeling of RF ablation by ignoring the cooling phase just after RF power is switched off

  • Irastorza, Ramiro Miguel
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] All the numerical models developed for radiofrequency ablation so far have ignored the possible effect of the cooling phase (just after radiofrequency power is switched off) on the dimensions of the coagulation zone. Our objective was thus to quantify the differences in the minor radius of the coagulation zone computed by including and ignoring the cooling phase. We built models of RF tumor ablation with 2 needle-like electrodes: a dry electrode (5mm long and 17G in diameter) with a constant temperature protocol (70 degrees C) and a cooled electrode (30mm long and 17G in diameter) with a protocol of impedance control. We observed that the computed coagulation zone dimensions were always underestimated when the cooling phase was ignored. The mean values of the differences computed along the electrode axis were always lower than 0.15mm for the dry electrode and 1.5mm for the cooled electrode, which implied a value lower than 5% of the minor radius of the coagulation zone (which was 3mm for the dry electrode and 30mm for the cooled electrode). The underestimation was found to be dependent on the tissue characteristics: being more marked for higher values of specific heat and blood perfusion and less marked for higher values of thermal conductivity., Agencia Nacional de Promocion Cientifica y Tecnologica de Argentina, Grant/Award Number: PICT-2012-1201; Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad, Grant/Award Number: TEC2014-52383-C3-R (TEC2014-52383-C3-1-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Analytical transient-time solution for temperature in non perfused tissue during radiofrequency ablation

  • López Molina, Juan Antonio
  • Berjano, Enrique|||0000-0002-3247-2665
  • Rivera Ortun, María José
[EN] Radiofrequency ablation (RFA) with internally cooled needle-like electrodes is a technique widely used to destroy cancer cells. In a previous study we obtained the analytical solution of the biological heat equation associated with the RFA problem in perfused tissue, i.e. when the governing equation which models the temperature distribution in tissue includes the blood perfusion therm. We also found that under these circumstances the temperature profiles always reach a steady state (limit temperature). However, the analytical solution of the RFA thermal problem without perfusion (e.g. conducted on an organ in which atraumatic vascular clamping is performed to temporally interrupt blood perfusion), cannot be directly obtained by setting the blood perfusion term to zero in the previously obtained solution. In fact, it is necessary to address the mathematical resolution in a totally different way. Our goal was to obtain the analytical expression of the temperature distribution in an RFA process with internally cooled needle-like electrodes when the biological tissue is not perfused. We consider two spatial domains: A finite domain which represents the real situation, and an infinite domain, which only makes sense from a mathematical point of view and which has been traditionally employed in analytical studies. Even though considering infinite time is not realistic, these approaches are surely worth considering in order to understand what happens "far from the electrode" or for "very long periods of time." The results indicate that the temperature value is finite both when the spatial domain is finite (which implies that a steady state is reached), and when time is finite for any spatial domain. From this it can be concluded that a steady state is never reached if the spatial domain is infinite. (C) 2016 Elsevier Inc. All rights reserved., This work received financial support from the Spanish "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Irreversible electroporation of the liver: Is there a safe limit to the ablation volume?

  • Sánchez-Velázquez, P.
  • Castellví, Q.
  • Villanueva, A.
  • Quesada, R.
  • Pañella, C.
  • Cáceres, M.
  • Dorcaratto, D.
  • Andaluz, A.
  • Moll, X.
  • Trujillo, M.
  • Burdió, J.M.
  • Berjano, E.
  • Grande, L.
  • Ivorra, A.
  • Burdió, F.
Irreversible electroporation is a fast-growing liver ablation technique. Although safety has been well documented in small ablations, our aim is to assess its safety and feasibility when a large portion of liver is ablated. Eighty-seven mice were subjected to high voltage pulses directly delivered across parallel plate electrodes comprising around 40% of mouse liver. One group consisted in 55 athymic-nude, in which a tumor from the KM12C cell line was grown and the other thirty-two C57-Bl6 non-tumoral mice. Both groups were subsequently divided into subsets according to the delivered field strength (1000 V/cm, 2000 V/cm) and whether or not they received anti-hyperkalemia therapy. Early mortality (less than 24 hours post-IRE) in the 2000 V/cm group was observed and revealed considerably higher mean potassium levels. In contrast, the animals subjected to a 2000 V/cm field treated with the anti-hyperkalemia therapy had higher survival rates (OR = 0.1, 95%CI = 0.02-0.32, p < 0.001). Early mortality also depended on the electric field magnitude of the IRE protocol, as mice given 1000 V/cm survived longer than those given 2000 V/cm (OR = 4.7, 95%CI = 1.8-11.8, p = 0.001). Our findings suggest that ionic disturbances, mainly due to potassium alterations, should be warned and envisioned when large volume ablations are performed by IRE.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis

  • Sánchez-Velázquez, P.
  • Castellví, Q.
  • Villanueva, A.
  • Iglesias, M.
  • Quesada, R.
  • Pañella, C.
  • Cáceres, M.
  • Dorcaratto, D.
  • Andaluz, A.
  • Moll, X.
  • Burdío, J. M.
  • Grande, L.
  • Ivorra, A.
  • Burdío, F.
Irreversible electroporation (IRE) has recently gained in popularity as an ablative technique, however little is known about its oncological long-term outcomes. To determine the long-time survival of animals treated with a high dose of IRE and which histological changes it induces in tumoral tissue, IRE ablation was performed in forty-six athymic-nude mice with KM12C tumors implanted in the liver by applying electric current with different voltages (2000 V/cm, 1000 V/cm). The tumors were allowed to continue to grow until the animals reached the end-point criteria. Histology was harvested and the extent of tumor necrosis was semi-quantitatively assessed. IRE treatment with the 2000 V/cm protocol significantly prolonged median mouse survival from 74.3 ± 6.9 days in the sham group to 112.5 ± 15.2 days in the 2000 V/cm group. No differences were observed between the mean survival of the 1000 V/cm and the sham group (83.2 ± 16.4 days, p = 0.62). Histology revealed 63.05% ± 23.12 of tumor necrosis in animals of the 2000 V/cm group as compared to 17.50% ± 2.50 in the 1000 V/cm group and 25.6% ± 22.1 in the Sham group (p = 0.001). IRE prolonged the survival of animals treated with the highest electric field (2000 V/cm). The animals in this group showed significantly higher rate of tumoral necrosis.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Anatomically realistic simulations of liver ablation by irreversible electroporation: impact of blood vessels on ablation volumes and undertreatment

  • Ivorra Cano, Antoni, 1974-
  • Qasrawi, Radwan Fayez Hasan
  • Silve, Louis Charles Arthur
  • Burdío Pinilla, Fernando
  • Abdeen, Ziad
Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible electroporation because of their influence on the electric field distribution. An anatomically realistic computer model of the liver and its vasculature within an abdominal section was employed, and blood vessels down to 0.4 mm in diameter were considered. In this model, the electric field distribution was simulated in a large series of scenarios (N = 576) corresponding to plausible percutaneous irreversible electroporation treatments by needle electrode pairs. These modeled treatments were relatively superficial (maximum penetration depth of the electrode within the liver = 26 mm) and it was ensured that the electrodes did not penetrate the vessels nor were in contact with them. In terms of total ablation volume, the maximum deviation caused by the presence of the vessels was 6%, which could be considered negligible compared to the impact by other sources of uncertainty. Sublethal field magnitudes were noticed around vessels covering volumes of up to 228 mm3. If in this model the blood was substituted by a liquid with a low electrical conductivity (0.1 S/m), the maximum volume covered by sublethal field magnitudes was 3.7 mm3 and almost no sublethal regions were observable. We conclude that undertreatment around blood vessels may occur in current liver ablation procedures by irreversible electroporation. Infusion of isotonic low conductivity liquids into the liver vasculature could prevent this risk., This work received financial support from the Spanish Government through grants TEC2010-17285, TEC2011-27133-C02, and TEC2014-52383-C3 (TEC2014-52383-C3-2) and from the European Commission through the Marie Curie IRG grant “TAMIVIVE” 256376.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Electrical modeling of the influence of medium conductivity on electroporation

  • Ivorra Cano, Antoni, 1974-
  • Villemejane, Julien
  • Mir, Lluis M.
Electroporation is the phenomenon in which cell membrane permeability is increased by exposing the cell to short high electric field pulses. Experimental data show that the amount of permeabilization depends on the conductivity of the extracellular medium. If medium conductivity decreases then it is necessary to deliver a pulse of larger field amplitude in order to achieve the same effect. Models that do not take into account the permeabilization effect on the membrane conductivity cannot reproduce qualitatively the experimental observations. Here we employ an exponential function for describing the strong dependence of membrane conductivity on transmembrane potential. Combining that model with numerical methods we demonstrate that the dependence on medium conductivity can be explained as being the result of increased membrane conductance due to electroporation. As experimentally observed, extracellular conductivities of about 1 and 0.1 S m−1 yield very similar results, however, for lower conductivities (<0.01 S m−1) the model predicts that significantly higher field magnitudes will be required to achieve the same amount of permeabilization., This work was supported by grants from: CNRS, Institute of cancerology Gustave-Roussy, University Paris Sud, INCa (National Institute of Cancer, France—contract number 07/3D1616/Doc-54-3NG-NC) and French National Agency (ANR) through Nanoscience and Nanotechnology program (Nanopulsebiochip no. ANR-08-NANO-024). AI’s research is currently supported by a Ramon y Cajal/nfellowship from the Spanish Ministry for Science and Innovation.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Electrochemical prevention of needle-tract seeding

  • Ivorra Cano, Antoni, 1974-
Needle-tract seeding refers to the implantation of tumor cells by contamination when instruments, such as biopsy needles, are employed to examine, excise or ablate a tumor. The incidence of this iatrogenic phenomenon is low but it entails serious consequences. Here, as a new method for preventing neoplasm seeding, it is proposed to cause electrochemical reactions at the instrument surface so that a toxic microenvironment is formed. In particular, the instrument shaft would act as the cathode and the tissues would act as the electrolyte in an electrolysis cell. By employing numerical models and experimental observations reported by researchers on Electrochemical Treatment of tumors, it is numerically showed that a sufficiently toxic environment of supraphysiological pH can be created in a few seconds without excessive heating. Then, by employing an ex vivo model consisting of meat pieces, validity of the conclusions provided by the numerical model concerning pH evolution is confirmed. Furthermore, a simplified in vitro model based on bacteria, instead of tumor cells, is implemented for showing the plausibility of the method. Depending on the geometry of the instrument, suitable current densities will probably range from about 5 mA/cm2 to 200 mA/cm2 and the duration of DC current delivery will range from a few seconds to a few minutes., AI’s research is currently supported by a Ramón y Cajal fellowship from the Spanish Ministry for Science and Innovation.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Dependence of electroporation detection threshold on cell radius: an explanation to observations non compatible with Schwan’s equation model

  • Mercadal, Borja
  • Vernier, P. Thomas
  • Ivorra Cano, Antoni, 1974-
It is widely accepted that electroporation occurs when the cell transmembrane voltage induced by an external applied electric field reaches a threshold. Under this assumption, in order to trigger electroporation in a spherical cell, Schwan’s equation leads to an inversely proportional relationship between the cell radius and the minimum magnitude of the applied electric field. And, indeed, several publications report experimental evidences of an inverse relationship between the cell size and the field required to achieve electroporation. However, this dependence is not always observed or is not as steep as predicted by Schwan’s equation. The present numerical study attempts to explain these observations that do not fit Schwan’s equation on the basis of the interplay between cell membrane conductivity, permeability, and transmembrane voltage. For that, a single cell in suspension was modeled and the electric field necessary to achieve electroporation with a single pulse was determined according to two effectiveness criteria: a specific permeabilization level, understood as the relative area occupied by the pores during the pulse, and a final intracellular concentration of a molecule due to uptake by diffusion after the pulse, during membrane resealing. The results indicate that plausible model parameters can lead to divergent dependencies of the electric field threshold on the cell radius. These divergent dependencies were obtained through both criteria and using two different permeabilization models. This suggests that the interplay between cell membrane conductivity, permeability, and transmembrane voltage might be the cause of results which are noncompatible with the Schwan’s equation model., This work was supported by the Ministry of Economy and Competitiveness of Spain through Grant TEC2014-52383-C3-2-R. PTV received support from the Old Dominion University Frank Reidy Research Center for Bioelectrics and the Air Force Office of Scientific Research (FA9550-15-1-0517, FA9550-14-1-0123).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

  • Ewertowska, Elżbieta
  • Andaluz, Anna
  • Moll, Xavier
  • Aguilar, Adrià
  • Garcia, Felix
  • Fondevila, Dolors
  • Quesada Diez, Rita
  • Trujillo Guillén, Macarena
  • Burdío Pinilla, Fernando
  • Berjano, Enrique J.
introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a ∼10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered ∼5 W of power on an initial impedance of 308 ± 60 Ω. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under “Plan Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” (Grant TEC2014–52383–C3–R) and by the Spanish Ministerio de Ciencia, Innovación y Universidades under “Programa Estatal de I + D + i Orientada a los Retos de la Sociedad" (Grant: RTI2018-094357-B-C21 and –C22). Elżbieta Ewertowska has a Predoctoral Grant (BES-2015–073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain). Also funding was received from Secretaría de Estado de Investigación, Desarrollo e Innovación.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis

  • Ivorra Cano, Antoni, 1974-
  • Sánchez Velázquez, Patricia, 1985-
  • Castellví Fernández, Quim
  • Villanueva, Alberto
  • Iglesias Coma, Mar
  • Quesada Diez, Rita
  • Pañella Vilamú, Clara, 1987-
  • Cáceres Aguilar, Mario
  • Dorcaratto, Dimitri
  • Andaluz, Anna
  • Moll, Xavier
  • Burdío, José M.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Irreversible electroporation (IRE) has recently gained in popularity as an ablative technique, however little is known about its oncological long-term outcomes. To determine the long-time survival of animals treated with a high dose of IRE and which histological changes it induces in tumoral tissue, IRE ablation was performed in forty-six athymic-nude mice with KM12C tumors implanted in the liver by applying electric current with different voltages (2000 V/cm, 1000 V/cm). The tumors were allowed to continue to grow until the animals reached the end-point criteria. Histology was harvested and the extent of tumor necrosis was semi-quantitatively assessed. IRE treatment with the 2000 V/cm protocol significantly prolonged median mouse survival from 74.3 ± 6.9 days in the sham group to 112.5 ± 15.2 days in the 2000 V/cm group. No differences were observed between the mean survival of the 1000 V/cm and the sham group (83.2 ± 16.4 days, p = 0.62). Histology revealed 63.05% ± 23.12 of tumor necrosis in animals of the 2000 V/cm group as compared to 17.50% ± 2.50 in the 1000 V/cm group and 25.6% ± 22.1 in the Sham group (p = 0.001). IRE prolonged the survival of animals treated with the highest electric field (2000 V/cm). The animals in this group showed significantly higher rate of tumoral necrosis., This research was supported by the spanish government under grants TEC2011-27133-c02 and TEC2010-17285, and by the spanish “plan estatal de investigación, desarrollo e innovación orientada a los retos de la sociedad” under grant TEC2014–52383-c3-r (TEC2014–52383-c3-2-r and TEC2014–52383-c3-3-r).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Endoluminal radiofrequency ablation of the main pancreatic duct is a secure and effective method to produce pancreatic atrophy and to achieve stump closure

  • Andaluz, Anna
  • Ewertowska, Elżbieta
  • Moll, Xavier
  • Aguilar, Adrià
  • García Arnas, Félix
  • Fondevila, Dolors
  • Quesada Diez, Rita
  • Berjano, Enrique J.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Radiofrequency energy has been used both experimentally and clinically to manage the pancreatic remnant after distal pancreatectomies. Our goal was to determine whether endoluminal radiofrequency (RF) ablation of the main pancreatic duct in large animals would be more efficient than glue occlusion as an exocrine pancreatic atrophy-inducing procedure. Thirty-four Landrace pigs were assigned to either the transpapilar (n = 16) or transection (n = 18) groups. The transection implied the pancreas neck was severed. In each of these groups the remaining distal pancreatic duct was occluded either by RF or by glue. In the transpapilar group complete atrophy was observed in all the RF cases, while atrophy was incomplete in all the members of the glue subgroup. The failure rate of the main pancreatic duct (usually expressed by a pseudocyst) in the transection groups was dramatically higher in the glue subgroup than the RF subgroups (9 out of 9 and 1 out of 9, respectively) and postoperative mortality occurred only in the glue subgroup (3 out of 9). These results show the superiority of endoluminal RF ablation over glue for main pancreatic duct occlusion, as seen by the degree of atrophy and fewer postoperative pancreatic fistulas., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under the “Plan Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” Grant TEC2014–52383–C3–R (TEC2014–52383–C3–1–R and TEC2014–52383–C3–3–R). Elzbieta Ewertowska has a Predoctoral Grant (BES-2015–073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Modeling liver electrical conductivity during hypertonic injection

  • Castellví Fernández, Quim
  • Sánchez Velázquez, Patricia, 1985-
  • Moll, Xavier
  • Berjano, Enrique J.
  • Andaluz, Anna
  • Burdío Pinilla, Fernando
  • Bijnens, Bart
  • Ivorra Cano, Antoni, 1974-
Metastases in the liver frequently grow as scattered tumor nodules which neither can be removed by surgical resection nor focally ablated. Previously, we have proposed a novel technique based on irreversible electroporation which may be able to simultaneously treat all nodules in the liver while sparing healthy tissue. The proposed technique requires increasing the electrical conductivity of healthy liver by injecting a hypersaline solution through the portal vein. Aiming to assess the capability of increasing the global conductivity of the liver by means of hypersaline fluids, here it is presented a mathematical model which estimates the NaCl distribution within the liver and the resulting conductivity change. The model fuses wellestablished compartmental pharmacokinetic models of the organ with saline injection models employed for resuscitation treatments and it considers changes in sinusoidal blood viscosity due to the hypertonicity of the solution. Here it is also described a pilot experimental study in pigs in which different volumes of NaCl 20% (from 100 to 200 ml) were injected through the portal vein at different flow rates (from 53 to 171 ml/min). The in vivo conductivity results fit those obtained by the model, both quantitatively and qualitatively, being able to predict the maximum conductivity with a 14.6% average relative error. The maximum conductivity value was 0.44 S/m which corresponds to increasing four times the mean basal conductivity (0.11 S/m). The results suggest that the presented model is well suited for predicting on liver conductivity changes during hypertonic saline injection., Spanish Government; contract/grant number: TEC2014-52383-C3-1-R, TEC2014-52383-C3-2-R and TEC2014-52383-C3-3-R
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Focused transhepatic electroporation mediated by hypersaline infusion through the portal vein in rat model: Preliminary results on differential conductivity

  • Pañella Vilamú, Clara, 1987-
  • Castellví Fernández, Quim
  • Moll, Xavier
  • Quesada Diez, Rita
  • Villanueva, Alberto
  • Iglesias Coma, Mar
  • Naranjo‐Hans, Dolores
  • Sánchez Velázquez, Patricia, 1985-
  • Andaluz, Anna
  • Grande Posa, Luís
  • Ivorra Cano, Antoni, 1974-
  • Burdío Pinilla, Fernando
Background. Spread hepatic tumours are not suitable for treatment either by surgery or conventional ablation methods. The aim of this study was to evaluate feasibility and safety of selectively increasing the healthy hepatic conductivity by the hypersaline infusion (HI) through the portal vein. We hypothesize this will allow simultaneous safe treatment of all nodules by irreversible electroporation (IRE) when applied in a transhepatic fashion. Material and methods. Sprague Dawley (Group A, n = 10) and Athymic rats with implanted hepatic tumour (Group B, n = 8) were employed. HI was performed (NaCl 20%, 3.8 mL/Kg) by trans-splenic puncture. Deionized serum (40 mL/Kg) and furosemide (2 mL/Kg) were simultaneously infused through the jugular vein to compensate hypernatremia. Changes in conductivity were monitored in the hepatic and tumour tissue. The period in which hepatic conductivity was higher than tumour conductivity was defined as the therapeutic window (TW). Animals were monitored during 1-month follow-up. The animals were sacrificed and selective samples were used for histological analysis. Results. The overall survival rate was 82.4% after the HI protocol. The mean maximum hepatic conductivity after HI was 2.7 and 3.5 times higher than the baseline value, in group A and B, respectively. The mean maximum hepatic conductivity after HI was 1.4 times higher than tumour tissue in group B creating a TW to implement selective IRE. Conclusions. HI through the portal vein is safe when the hypersaline overload is compensated with deionized serum and it may provide a TW for focused IRE treatment on tumour nodules., This work received financial support from the Spanish Government (Ministry of Economy and Competitiveness) under Grant TEC2014-52383-C3. The authors disclose no conflicts of interests.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Charge counter for performing active charge-balance in miniaturized electrical stimulators

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Functional Electrical Stimulation (FES) has been explored in order to restore the capabilities of the nervous system in patients that suffer from paralysis. This area of research and of clinical practice greatly benefits from any technological improvement yielding miniaturization. In this regard, we recently proposed and demonstrated an innovative electrical stimulation method based on implanted microstimulators that operate as rectifiers of bursts of innocu-ous high frequency current supplied by skin electrodes, gener-ating low frequency currents that are capable of stimulating excitable tissues. We envision flexible ultrathin implants (di-ameters < 300 μm) containing ASICs that have advanced ca-pabilities, such as addressability and current control. As min-iaturization is the main aim of this method, the use of bulky DC-blocking capacitors (e.g. 10 μF) to accomplish zero net charge injection and avoid electrochemical tissue and electrode damage is highly inconvenient. As an alternative, here we present an active charge-balance method based on the use of a digital charge quantifier, whose operation is inspired in the functioning of the tipping bucket rain gauge. The system moni-tors the charge injection, matching the charge injected in the cathodal phase, with the charge injected in the anodal phase, generating a biphasic current waveform that adapts itself to possible current source mismatches. We have implemented a prototype built with discrete components which uses a capaci-tor of only 100 pF for the charge counter., AI’s research is supported by a Ramón y Cajal fellowship/nfrom the Spanish government and a Marie Curie grant/n(IRG 256376) from the European Commission. LBF’s research/nis supported by a scholarship from the UPF.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Impact of monopolar radiofrequency coagulation on intraoperative blood loss during liver resection: a prospective randomised controlled trial

  • Quesada Diez, Rita
  • Poves Prim, José Ignacio
  • Berjano, Enrique J.
  • Vilaplana, Carles
  • Andaluz, Anna
  • Moll, Xavier
  • Dorcaratto, Dimitri
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
PURPOSE: To evaluate the impact of using monopolar thermal coagulation based on radiofrequency (RF) currents on intraoperative blood loss during liver resection. MATERIALS AND METHODS: A prospective randomised controlled trial was planned. Patients undergoing hepatectomy were randomised into two groups. In the control group (n = 10), hemostasis was obtained with a combination of stitches, vessel-sealing bipolar RF systems, sutures or clips. In the monopolar radiofrequency coagulation (MRFC) group (n = 18), hemostasis was mainly obtained using an internally cooled monopolar RF electrode. RESULTS: No differences in demographic or clinical characteristics were found between groups. Mean blood loss during liver resection in the control group was more than twice that of the MRFC group (556 ± 471 ml vs. 225 ± 313 ml, p = .02). The adjusted mean bleeding/transection area was also significantly higher in the control group (7.0 ± 3.3 ml/cm2 vs. 2.8 ± 4.0 ml/cm2, p = .006). No significant differences were observed in the rate of complications between the groups. CONCLUSIONS: The findings suggest that the monopolar electrocoagulation created with an internally cooled RF electrode considerably reduces intraoperative blood loss during liver resection., This work was supported by a medical research grant from the Spanish Government (FIS PI080934) and by Spanish “Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” under Grant TEC2014–52383-C3-R (TEC2014–52383-C3–1-R and TEC2014–52383-C3–3-R)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Dynamics of cell death after conventional IRE and H-FIRE treatments

  • Mercadal, Borja
  • Beitel White, Natalie
  • Aycock, Kenneth N.
  • Castellví Fernández, Quim
  • Davalos, Rafael Vidal
  • Ivorra Cano, Antoni, 1974-
High-frequency irreversible electroporation (H-FIRE) has emerged as an alternative to conventional irreversible electroporation (IRE) to overcome the issues associated with neuromuscular electrical stimulation that appear in IRE treatments. In H-FIRE, the monopolar pulses typically used in IRE are replaced with bursts of short bipolar pulses. Currently, very little is known regarding how the use of a different waveform affects the cell death dynamics and mechanisms. In this study, human pancreatic adenocarcinoma cells were treated with a typical IRE protocol and various H-FIRE schemes with the same energized time. Cell viability, membrane integrity and Caspase 3/7 activity were assessed at different times after the treatment. In both treatments, we identified two different death dynamics (immediate and delayed) and we quantified the electric field ranges that lead to each of them. While in the typical IRE protocol, the electric field range leading to a delayed cell death is very narrow, this range is wider in H-FIRE and can be increased by reducing the pulse length. Membrane integrity in cells suffering a delayed cell death shows a similar time evolution in all treatments, however, Caspase 3/7 expression was only observed in cells treated with H-FIRE., This work was supported by the Ministry of Economy and Competitiveness of Spain (Grant No. TEC2014-52383-C3-2-R), the Pancreatic Cancer Action Network (Grant No. 16-65-IANN) and Cures Within Reach (Grant No. PUJFSANY). Antoni Ivorra gratefully acknowledges financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

EView: an electric field visualization web platform for electroporation-based therapies

  • Perera Bel, Enric
  • Yagüe, Carlos
  • Mercadal, Borja
  • Ceresa, Mario
  • Beitel White, Natalie
  • Davalos, Rafael Vidal
  • González Ballester, Miguel Ángel, 1973-
  • Ivorra Cano, Antoni, 1974-
Background and objectives: Electroporation is the phenomenon by which cell membrane permeability to ions and macromolecules is increased when the cell is briefly exposed to high electric fields. In electroporation-based treatments, such exposure is typically performed by delivering high voltage pulses across needle electrodes in tissue. For a given tissue and pulsing protocol, an electric field magnitude threshold exists that must be overreached for treatment efficacy. However, it is hard to preoperatively infer the treatment volume because the electric field distribution intricately depends on the electrodes’ positioning and length, the applied voltage, and the electric conductivity of the treated tissues. For illustrating such dependencies, we have created EView (https://eview.upf.edu), a web platform that estimates the electric field distribution for arbitrary needle electrode locations and orientations and overlays it on 3D medical images. Methods: A client-server approach has been implemented to let the user set the electrode configuration easily on the web browser, whereas the simulation is computed on a dedicated server. By means of the finite element method, the electric field is solved in a 3D volume. For the sake of simplicity, only a homogeneous tissue is modeled, assuming the same properties for healthy and pathologic tissues. The non-linear dependence of tissue conductivity on the electric field due to the electroporation effect is modeled. The implemented model has been validated against a state of the art finite element solver, and the server has undergone a heavy load test to ensure reliability and to report execution times. Results: The electric field is rapidly computed for any electrode and tissue configuration, and alternative setups can be easily compared. The platform provides the same results as the state of the art finite element solver (Dice = 98.3 ± 0.4%). During the high load test, the server remained responsive. Simulations are computed in less than 2 min for simple cases consisting of two electrodes and take up to 40 min for complex scenarios consisting of 6 electrodes. Conclusions: With this free platform we provide expert and non-expert electroporation users a way to rapidly model the electric field distribution for arbitrary electrode configurations., This work was supported by the Ministry of Economy and Competitiveness of Spain (grant number TEC2014-52383-C3-2-R), the María de Maeztu Units of Excellence Programme (grant number MDM-2015-0502) and by the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (grant number BES-2017-081164). Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Modeling methods for treatment planning in overlapping electroporation treatments

  • Perera Bel, Enric
  • Mercandal, Borja
  • Garcia-Sanchez, Tomas
  • González Ballester, Miguel Ángel, 1973-
  • Ivorra Cano, Antoni, 1974-
Objective: Irreversible electroporation (IRE) is a non thermal tissue ablation therapy which is induced by applying high voltage waveforms across electrode pairs. When multiple electrode pairs are sequentially used, the treatment volume (TV) is typically computed as the geometric union of the TVs of individual pairs. However, this method neglects that some regions are exposed to overlapping treatments. Recently, a model describing cell survival probability was introduced which effectively predicted TV with overlapping fields in vivo. However, treatment overlap has yet to be quantified. This study characterizes TV overlap in a controlled in vitro setup with the two existing methods which are compared to an adapted logistic model proposed here. Methods: CHO cells were immobilized in agarose gel. Initially, we characterized the electric field threshold and the cell survival probability for overlapping treatments. Subsequently, we created a 2D setup where we compared and validated the accuracy of the different methods in predicting the TV. Results: Overlap can reduce the electric field threshold required to induce cell death, particularly for treatments with low pulse number. However, it does not have a major impact on TV in the models assayed here, and all the studied methods predict TV with similar accuracy. Conclusion: Treatment overlap has a minor influence in the TV for typical protocols found in IRE therapies. Significance: This study provides evidence that the modeling method used in most pre-clinical and clinical studies seems adequate.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Avoiding neuromuscular stimulation in liver irreversible electroporation using radiofrequency electric fields

  • Castellví Fernández, Quim
  • Mercadal, Borja
  • Moll, Xavier
  • Fondevila, Dolors
  • Andaluz, Anna
  • Ivorra Cano, Antoni, 1974-
Electroporation based treatments typically consist in applying high voltage dc pulses. As an undesired side effect, these dc pulses cause electrical stimulation of excitable tissues such as motor nerves. In the present in vivo study, it was explored the use of bursts of sinusoidal voltage in the frequency range from 50 kHz to 2 MHz to induce irreversible electroporation (IRE) whilst avoiding neuromuscular stimulation. Series of 100 dc pulses or sinusoidal bursts, both with an individual duration of 100 μs, were delivered to rabbit liver through thin needles in a monopolar electrode configuration and thoracic movements were recorded with an accelerometer. Tissue samples were harvested three hours after treatment and later postprocessed to determine the dimensions of the IRE lesions. Thermal damage due to Joule heating was ruled out via computer simulations. Sinusoidal bursts with a frequency equal or above 100 kHz did not cause thoracic movements and induced lesions equivalent to those obtained with conventional dc pulses when the applied voltage amplitude was sufficiently high. IRE efficacy dropped with increasing frequency. For 100 kHz bursts, it was estimated that the electric field threshold for IRE is about 1.4 kV/cm whereas that of dc pulses is about 0.5 kV/cm., This work was supported by the Ministry of Economy and Competitiveness of Spain through the grant TEC2014-52383-C3-R (TEC2014-52383-C3-2-R and TEC2014-52383-C3-3-R).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Avoiding nerve stimulation in irreversible electroporation: a numerical modeling study

  • Mercadal, Borja
  • Arena, Christopher B.
  • Davalos, Rafael Vidal
  • Ivorra Cano, Antoni, 1974-
Electroporation based treatments consist in applying one or multiple high voltage pulses to the tissues to be treated. As an undesired side effect, these pulses cause electrical stimulation of excitable tissues such as nerves and muscles. This increases the complexity of the treatments and may pose a risk to the patient. To minimize electrical stimulation during electroporation based treatments, it has been proposed to replace the commonly used monopolar pulses by bursts of short bipolar pulses. In the present study, we have numerically analyzed the rationale for such approach. We have compared different pulsing protocols in terms of their electroporation efficacy and their capability to trigger action potentials in nerves. For that, we have developed a modeling framework that combines numerical models of nerve fibers and experimental data on irreversible electroporation. Our results indicate that, by replacing the conventional relatively long monopolar pulses by bursts of short bipolar pulses, it is possible to ablate a large tissue region without triggering action potentials in a nearby nerve. Our models indicate that this is possible because, as the pulse length of these bipolar pulses is reduced, the stimulation thresholds raise faster than the irreversible electroporation thresholds. We propose that this different dependence on the pulse length is due to the fact that transmembrane charging for nerve fibers is much slower than that of cells treated by electroporation because of their geometrical differences., This work was supported by the Ministry of Economy and Competitiveness of Spain through the grant TEC2014-52383-C3-2-R. RVD’s research is supported by the National Institutes of Health under award number NIH 1R21 CA192041-01.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Pulsed radiofrequency for chronic pain: In vitro evidence of an electroporation mediated calcium uptake

  • Mercadal, Borja
  • Vicente García, Rubén, 1978-
  • Ivorra Cano, Antoni, 1974-
Pulsed radiofrequency (PRF) treatments for chronic pain consist in the delivery of a train of sinusoidal electric bursts to the targeted nerve. Despite numerous clinical evidence of its efficiency, the mechanism of action of PRF remains unclear. Since most of the reported biological effects of PRF can be initiated by a calcium influx into the neurons, we hypothesized that PRF may induce a mild electroporation effect causing a calcium uptake. To test this hypothesis, HEK-293 cells were exposed to PRF bursts and cytosolic calcium and Yo-Pro-1 uptake were monitored. After a single burst, calcium peaks were observed for electric fields above 480 V/cm while the uptake of Yo-pro-1 was insignificant. After a train of 120 bursts, the electric fields required to induce a calcium and Yo-pro-1 uptake decreased to 330 V/cm and 880 V/cm respectively. Calcium peaks were not detected when cells were treated in calcium free media. The temperature increase during the treatments was lower than 5 °C in all cases. Finally, the cell response for different burst frequencies and extracellular media conductivities correlated with the induced transmembrane voltage calculated with a numerical model. Our results support the hypothesis of an electroporation mediated calcium influx., This work was supported by the Ministry of Economy and Competitiveness of Spain through the grants TEC2014-52383-C3-2-R and SAF2014-52228-R. Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Laparoscopic partial splenectomy for giant cyst using a radiofrequency-assisted device: a case report

  • Quesada Diez, Rita
  • Poves Prim, José Ignacio
  • Iglesias Coma, Mar
  • Berjano, Enrique J.
  • Grande Posa, Luís
  • Burdío Pinilla, Fernando
Background: Although radiofrequency-assisted devices have sometimes been used in partial splenectomy, this is not a common technique. This report describes the first case of laparoscopic partial splenectomy using an RF-assisted device (Coolinside) which allows both coagulation and transection of the parenchyma and eventually the protective coagulation of the remnant side. Case presentation: A 27-year-old woman was found to have a giant hydatic cyst measuring 12.0 × 14.0 × 16.6 cm that mainly occupied the lower pole of the spleen and retroperitoneal space. The patient underwent a laparoscopic partial splenectomy using an RF-based device designed to accomplish both the coagulation and dissection of the splenic tissue. The estimated blood loss was less than 200 mL. Conclusions: Even though RF ablation has traditionally been used for hepatic parenchymal transection, it seems equally suited to partial splenectomy. This device seems to provide good results, minimizing blood loss during partial splenectomy; however, randomized trials will be necessary to see if the results are superior to those of other techniques., This work was partially supported by the Spanish “Programa Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R and TEC2014-52383-C3-3-R).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Focused transhepatic electroporation mediated by hypersaline infusion through the portal vein in rat model, preliminary results on differential conductivity

  • Pañella, Clara
  • Castellví, Quim|||0000-0002-7095-1181
  • Moll, Xavier|||0000-0002-2992-9361
  • Quesada, R.|||0000-0002-8264-0356
  • Villanueva, Alejandro|||0000-0001-5164-0006
  • Iglesias, Mar|||0000-0002-2274-4671
  • Naranjo-Hans, Dolores|||0000-0002-4089-047X
  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Grande, L.|||0000-0001-9146-9004
  • Ivorra, Antoni|||0000-0001-7718-8767
  • Burdío, Fernando|||0000-0003-3038-0086
Spread hepatic tumours are not suitable for treatment either by surgery or conventional ablation methods. The aim of this study was to evaluate feasibility and safety of selectively increasing the healthy hepatic conductivity by the hypersaline infusion (HI) through the portal vein. We hypothesize this will allow simultaneous safe treatment of all nodules by irreversible electroporation (IRE) when applied in a transhepatic fashion. Sprague Dawley (Group A, n = 10) and Athymic rats with implanted hepatic tumour (Group B, n = 8) were employed. HI was performed (NaCl 20%, 3.8 mL/Kg) by trans-splenic puncture. Deionized serum (40 mL/Kg) and furosemide (2 mL/Kg) were simultaneously infused through the jugular vein to compensate hypernatremia. Changes in conductivity were monitored in the hepatic and tumour tissue. The period in which hepatic conductivity was higher than tumour conductivity was defined as the therapeutic window (TW). Animals were monitored during 1-month follow-up. The animals were sacrificed and selective samples were used for histological analysis. The overall survival rate was 82.4% after the HI protocol. The mean maximum hepatic conductivity after HI was 2.7 and 3.5 times higher than the baseline value, in group A and B, respectively. The mean maximum hepatic conductivity after HI was 1.4 times higher than tumour tissue in group B creating a TW to implement selective IRE. HI through the portal vein is safe when the hypersaline overload is compensated with deionized serum and it may provide a TW for focused IRE treatment on tumour nodules.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Endoluminal radiofrequency ablation of the main pancreatic duct is a secure and effective method to produce pancreatic atrophy and to achieve stump closure

  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Ewertowska, Elzbieta
  • Moll, Xavier|||0000-0002-2992-9361
  • Aguilar Catalán, Adrià|||0000-0003-2403-9383
  • García Arnas, Félix|||0000-0001-6651-3173
  • Fondevila, Dolors|||0000-0001-7443-0175
  • Quesada, Rita
  • Berjano, Enrique|||0000-0002-3247-2665
  • Grande, L|||0000-0001-9146-9004
  • Burdío, Fernando|||0000-0003-3038-0086
Radiofrequency energy has been used both experimentally and clinically to manage the pancreatic remnant after distal pancreatectomies. our goal was to determine whether endoluminal radiofrequency (RF) ablation of the main pancreatic duct in large animals would be more efficient than glue occlusion as an exocrine pancreatic atrophy-inducing procedure. thirty-four Landrace pigs were assigned to either the transpapilar (n = 16) or transection (n = 18) groups. The transection implied the pancreas neck was severed. In each of these groups the remaining distal pancreatic duct was occluded either by RF or by glue. In the transpapilar group complete atrophy was observed in all the RF cases, while atrophy was incomplete in all the members of the glue subgroup. the failure rate of the main pancreatic duct (usually expressed by a pseudocyst) in the transection groups was dramatically higher in the glue subgroup than the RF subgroups (9 out of 9 and 1 out of 9, respectively) and postoperative mortality occurred only in the glue subgroup (3 out of 9). These results show the superiority of endoluminal RF ablation over glue for main pancreatic duct occlusion, as seen by the degree of atrophy and fewer postoperative pancreatic fistulas.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Long-term effectiveness of irreversible electroporation in a murine model of colorectal liver metastasis

  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
  • Castellví, Quim|||0000-0002-7095-1181
  • Villanueva Garatachea, Alberto
  • Iglesias, Mar|||0000-0002-2274-4671
  • Quesada, R.|||0000-0002-8264-0356
  • Pañella, Clara
  • Cáceres, Marta|||0000-0002-4100-2542
  • Dorcaratto, Dimitri
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • Burdio, José Miguel
  • Grande, L.|||0000-0001-9146-9004
  • Ivorra, Antoni|||0000-0001-7718-8767
  • Burdío, Fernando|||0000-0003-3038-0086
Irreversible electroporation (IRE) has recently gained in popularity as an ablative technique, however little is known about its oncological long-term outcomes. To determine the long-time survival of animals treated with a high dose of IRE and which histological changes it induces in tumoral tissue, IRE ablation was performed in forty-six athymic-nude mice with KM12C tumors implanted in the liver by applying electric current with different voltages (2000V/cm, 1000V/cm). The tumors were allowed to continue to grow until the animals reached the end-point criteria. Histology was harvested and the extent of tumor necrosis was semi-quantitatively assessed. IRE treatment with the 2000V/cm protocol significantly prolonged median mouse survival from 74.3±6.9 days in the sham group to 112.5±15.2 days in the 2000V/cm group. No differences were observed between the mean survival of the 1000V/cm and the sham group (83.2±16.4 days, p=0.62). Histology revealed 63.05%±23.12 of tumor necrosis in animals of the 2000V/cm group as compared to 17.50%±2.50 in the 1000V/cm group and 25.6%±22.1 in the Sham group (p=0.001). IRE prolonged the survival of animals treated with the highest electric field (2000V/cm). The animals in this group showed significantly higher rate of tumoral necrosis.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Irreversible electroporation of the liver, is there a safe limit to the ablation volume?

  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
  • Castellví, Quim|||0000-0002-7095-1181
  • Villanueva Garatachea, Alberto
  • Quesada, R.|||0000-0002-8264-0356
  • Pañella, Clara
  • Cáceres, Marta|||0000-0002-4100-2542
  • Dorcaratto, Dimitri
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • Trujillo Guillén, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
  • Grande, L.|||0000-0001-9146-9004
  • Ivorra, Antoni|||0000-0001-7718-8767
  • Burdío, Fernando|||0000-0003-3038-0086
Irreversible electroporation is a fast-growing liver ablation technique. Although safety has been well documented in small ablations, our aim is to assess its safety and feasibility when a large portion of liver is ablated. Eighty-seven mice were subjected to high voltage pulses directly delivered across parallel plate electrodes comprising around 40% of mouse liver. One group consisted in 55 athymicnude, in which a tumor from the KM12C cell line was grown and the other thirty-two C57-Bl6 nontumoral mice. Both groups were subsequently divided into subsets according to the delivered field strength (1000V/cm, 2000V/cm) and whether or not they received anti-hyperkalemia therapy. Early mortality (less than 24hours post-IRE) in the 2000V/cm group was observed and revealed considerably higher mean potassium levels. In contrast, the animals subjected to a 2000V/cm field treated with the anti-hyperkalemia therapy had higher survival rates (OR=0.1, 95%CI=0.02-0.32, p<0.001). Early mortality also depended on the electric field magnitude of the IRE protocol, as mice given 1000V/cm survived longer than those given 2000V/cm (OR=4.7, 95%CI=1.8-11.8, p=0.001). Our findings suggest that ionic disturbances, mainly due to potassium alterations, should be warned and envisioned when large volume ablations are performed by IRE.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Hypersaline Infusion Protocol through the Portal Vein may Focus Electroporation on Tumor Tissue, but is it really Safe? Preliminary Results

  • Pañella, Clara
  • Moll, Xavier|||0000-0002-2992-9361
  • Quesada, R.|||0000-0002-8264-0356
  • Villanueva Garatachea, Alberto
  • Iglesias, Mar|||0000-0002-2274-4671
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Lucía, O.
  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
  • Grande, L.|||0000-0001-9146-9004
  • Burdío, Fernando|||0000-0003-3038-0086
Introduction: Irreversible Electroporation (IRE) is highly dependent on the electrical conductivity of the tissue and the high conductivity of tumor tissue, which leads to a lower field than in the surrounding healthy tissue. Hypersaline Infusion (HI) through the portal vein focuses IRE on scattered liver tumors, by creating a differential conductivity between the different types of tissue. The aim of this study is to determine the effects of the HI protocol on the hepatic and histological biochemical results. Methods: Ten male Sprague Dawley rats were used for HI protocol. Blood samples were collected at pre-, immediately post-, 24-hrs, 72-hrs, 1-week and 3-weeks post-HI. All the animals were sacrificed after one-month follow-up in order to collect histological samples. Results: The mortality rate in this procedure reached 30% (3/10). Only the pH and transaminases at 24-hrs were significantly and directly linked to mortality (p=0.036 and p=0.004, respectively). The three non-surviving animals had a four-time higher AST level at 24-hrs. Natremia normalized at 24-hrs post-HI. Statistically significant differences were found in hepatic necrosis between the non-surviving (n=3) and surviving rats (n=7) (30.67 ± 10.97 vs. 2.86 ± 7.56% respectively, p=0.01). Discussion: HI through the portal system involves a significant risk of possibly lethal cytolysis and acidosis. Therefore, compensatory measures and a reduced saline overload are warranted to improve the survival rates.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

A clinically oriented computer model for radiofrequency ablation of hepatic tissue with internally cooled wet electrode

  • Ewertowska, Elzbieta
  • Quesada, R.|||0000-0002-8264-0356
  • Radosevic, Aleksandar
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • García Arnas, Félix.|||0000-0001-6651-3173
  • Berjano, Enrique|||0000-0002-3247-2665
  • Burdío, Fernando|||0000-0003-3038-0086
  • Trujillo Guillén, Macarena|||0000-0003-4145-2188
Purpose: To improve the computer modelling of radiofrequency ablation (RFA) by internally cooled wet (ICW) electrodes with added clinically oriented features. Methods: An improved RFA computer model by ICW electrode included: (1) a realistic spatial distribution of the infused saline, and (2) different domains to distinguish between healthy tissue, saline-infused tumour, and non-infused tumour, under the assumption that infused saline is retained within the tumour boundary. A realistic saline spatial distribution was obtained from an in vivo pig liver study. The computer results were analysed in terms of impedance evolution and coagulation zone (CZ) size, and were compared to the results of clinical trials conducted on 17 patients with the same ICW electrode. Results: The new features added to the model provided computer results that matched well with the clinical results. No roll-offs occurred during the 4-min ablation. CZ transversal diameter (4.10 ± 0.19 cm) was similar to the computed diameter (4.16 cm). Including the tumour and saline infusion in the model involved (1) a reduction of the initial impedance by 10 - 20 Ω, (2) a delay in roll-off of 20 s and 70 - 100 s, respectively, and (3) 18 - 31% and 22 - 36% larger CZ size, respectively. The saline spatial distribution geometry was also seen to affect roll-off delay and CZ size. Conclusions: Using a three-compartment model and a realistic saline spatial distribution notably improves the match with the outcome of the clinical trials.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

  • Ewertowska, Elzbieta
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • Aguilar Catalán, Adrià|||0000-0003-2403-9383
  • García Arnas, Félix|||0000-0001-6651-3173
  • Fondevila, Dolors|||0000-0001-7443-0175
  • Quesada, R.|||0000-0002-8264-0356
  • Trujillo Guillén, Macarena|||0000-0003-4145-2188
  • Burdío, Fernando|||0000-0003-3038-0086
  • Berjano, Enrique|||0000-0002-3247-2665
Introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a ∼10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered ∼5 W of power on an initial impedance of 308 ± 60 Ω. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Impact of monopolar radiofrequency coagulation on intraoperative blood loss during liver resection, a prospective randomised controlled trial

  • Quesada, Rita
  • Poves, Ignasi
  • Berjano, Enrique|||0000-0002-3247-2665
  • Vilaplana, Carles
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • Dorcaratto, Dimitri
  • Grande, L|||0000-0001-9146-9004
  • Berjano, Enrique|||0000-0002-3247-2665
To evaluate the impact of using monopolar thermal coagulation based on radiofrequency (RF) currents on intraoperative blood loss during liver resection. A prospective randomised controlled trial was planned. Patients undergoing hepatectomy were randomised into two groups. In the control group (n = 10), hemostasis was obtained with a combination of stitches, vessel-sealing bipolar RF systems, sutures or clips. In the monopolar radiofrequency coagulation (MRFC) group (n = 18), hemostasis was mainly obtained using an internally cooled monopolar RF electrode.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Radiofrequency-induced heating versus mechanical stapler for pancreatic stump closure, in vivo comparative study

  • Burdío, Fernando|||0000-0003-3038-0086
  • Dorcaratto, Dimitri
  • Hernandez, Lourdes
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • Quesada, Rita
  • Poves, Ignasi
  • Grande, L|||0000-0001-9146-9004
  • Cáceres, Marta|||0000-0002-4100-2542
  • Berjano, Enrique|||0000-0002-3247-2665
The aim of this study was to assess the capacity of two methods of surgical pancreatic stump closure in terms of reducing the risk of pancreatic fistula formation (POPF): radiofrequency-induced heating versus mechanical stapler. Sixteen pigs underwent a laparoscopic transection of the neck of the pancreas. Pancreatic anastomosis was always avoided in order to work with an experimental model prone to POPF. Pancreatic stump closure was conducted either by stapler (ST group, n = 8) or radiofrequency energy (RF group, n = 8). Both groups were compared for incidence of POPF and histopathological alterations of the pancreatic remnant.