Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Characterization of the effects of right ventricular and left bundle branch area pacing on the QRS complex

  • Sales Belles, C
  • Melero Polo, J
  • Cabrera Ramos, M
  • Vadillo Martin, P
  • Mayo Carlos, V
  • Palacios Rosales, S
  • Martinez Cortes, J P
  • Minchole Lapuente, A
  • Pueyo Paules, E
  • Ramos Maqueda, J
Introduction: Right ventricular pacing (RVP) has been the treatment of choice for patients with atrioventricular block and sinus node disease for the last decades . It is well known that RVP ventricular may cause ventricular dyssynchrony and could lead to left ventricular dysfunction in 20% of patients, and therefore could increase the risk of heart failure, atrial fibrillation and cardiovascular mortality. Left bundle branch area pacing (LBBAP) has recently emerged as a new physiological pacing modality that can circumvent the limitations of RVP. The purpose of this study was to compare changes induced by RVP and LBBAP in the standard 12-lead ECG by the analysis of QRS complex characteristics in order to asses ventricular dyssynchrony. Methods: ECG recordings from 134 patients (82 LBBAP, 52 RVP) with indication for anti-bradycardia therapy were acquired before and after pacemaker implantation. Patients were grouped into narrow and wide baseline QRS using a threshold for the QRS duration of 120 ms. Median beats were calculated at baseline and 24 hours post-implantation states for each patient. ECG markers describing ventricular activation were measured, including: 1) QRS duration (QRSd) from QRS onset to QRS end; 2) QRS area (QRSa), computed from the individual areas in orthogonal X, Y and Z leads calculated using the Kors conversion matrix; 3) a new index QRS50 proposed to estimate the ventricular activation time from the first three components of the singular value decomposition of the median QRS complex. Results: Note that the QRS characteristics showed similar values in baseline for both pacing techniques. In patients with narrow QRS, we found that paced QRS characteristics remained similar from the basal QRS in LBBAP group whereas in RVP group they worsened. The three markers, QRSd, QRSa and QRS50, increased after RVP by 34 ms, 68 uVs and 22 ms, respectively (p<0,001). In patients with wide QRS, LBBAP significantly reduced QRSd, QRSa and QRS50 while RVP increased QRSa and QRS50 and left QRSd unchanged. Conclusion: In patients receiving a pacemaker for anti-bradycardia therapy, LBBAP led to more synchronized ventricular activation than RVP measured from QRS duration- and area-related characteristics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Depolarization-repolarization synchrony after right ventricular and left bundle branch area pacing

  • Sales Belles, C
  • Melero Polo, J
  • Cabrera Ramos, M
  • Minchole Lapuente, A
  • Pueyo Paules, E
  • Ramos Maqueda, J
Introduction: Left bundle branch area pacing (LBBAP) has been recently proposed to overcome the limitations associated with right ventricular pacing (RVP) and has been suggested as a new physiological pacing form with high feasibility and safety. A greater difference between QRS complex and T-wave angle directions has been proposed as a marker of abnormal electrical activity in several patient populations, but a comparison between these two pacing modalities has never been performed. The total cosine R to T (TCRT) is an ECG descriptor that accounts for depolarization-repolarization synchrony by measuring the difference between their directions. The purpose of this study was to compare TCRT in patients referred for RVP and LBBAP pacing as anti-bradycardia therapy. Methods: ECG recordings from 134 patients (82 LBBAP, 52 RVP) were classified into two groups, narrow QRS and wide QRS, depending on the patient’s QRS duration prior to implantation. In the post-implantation state, the TCRT index was calculated from a median beat calculated for each patient. Singular value decomposition was applied to the median beat in the eight independent ECG leads (I, II, V1, V2, V3, V4, V5, V6). The QRS complex and T wave loops in a three-dimensional space were determined from the first three components of the decomposition. TCRT was computed as the average of the cosines of the angles between the QRS complex directions and the maximum T wave direction. More positive values corresponded to more synchronized depolarization and repolarization processes while more negative values indicated larger differences in the orientation of the QRS and T wave loops and, therefore, greater dyssynchronization. Results: showed that TCRT took negative values for both techniques, RVP and LBBAP, and both groups, narrow and wide QRS, indicating that pacing generated dyssynchronization between ventricular depolarization and repolarization. Nevertheless, TCRT values for both groups were significantly more negative (p<0.01) for RVP than for LBBAP. We hypothesize that cardiac memory induced by pacing could account for these negative TCRT values. In any case, LBBAP did not increase the difference in the QRS complex and T wave loop orientations as much as RVP. Conclusion: LBBAP induces less dyssynchrony than RVP in the depolarization-repolarization process.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Changes in T-peak-to-T-end Morphology Measured by Time-Warping Are Associated with Ischemia-Induced Ventricular Fibrillation in a Porcine Model

  • Gómez Fonseca, Neurys
  • Ramírez, Julia
  • Martin-Yebra, Alba
  • M. Demidova, Marina
  • Platonov, Pyotr
  • Martínez, Juan Pablo
  • Laguna, Pablo
In this work, we use a time-warping-based morphology variation index, dw , computed between the peak and the end of the T-wave, and assess its association with the occurrence of ventricular fibrillation (VF) episodes in ischemic conditions. ECG recordings from 26 pigs under- going a 40-minute coronary occlusion were analyzed. The dw series was obtained by quantifying the morphological differences between the final part of the T wave at different stages of the occlusion and a reference T wave in the control recording. During control recordings, dw remained stationary with a median value along each recording of 1.76 ms, IQR of 1.80, while during artery occlusion followed a well-marked gradual increasing trend as ischemia progressed, with median of 15.47 ms, IQR of 18.53. At the 20-to-25 min period from occlusion onset (and during 5 min prior to VF episode) d w averages in the VF group was significantly higher than in the non-VF group with median values of 40.0 (and 34.4) vs 7.8 (and 7.7) ms, with p-values of 0.002 (and 0.001), respectively. In conclusion, dynamic increases of the dw index during ischaemia progression in pigs are associated with VF occurrence.