Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Surface properties of clinker phases and clay minerals characterized by inverse gas chromatography (IGC) and their link to reactivity

  • Zunino, Franco
  • Palacios, Marta
  • Bowen, Paul
  • Scrivener, Karen L.
[Description of methods used for collection/generation of data] IGC measurements at infinite dilution (IGC-ID) and finite dilution (IGC-FD) were carried out using a PerkinElmer Clarus 400 chromatography meter coupled with an Agilent AMD 1000 flowmeter to control the gas injections. The analysis of recorded chromatograms to obtain the isotherms was conducted using the CGI-CF V 709G software from Adscientis. For the determination of energy distribution functions, the FDRJ 07.5.F software from Adscientis was used. For the measurements at infinite dilution (IGC-ID), C3S-I, C3S-II and C3A samples were placed in a 6.4 mm (1/4 in.) measuring column, with an internal diameter of 4 mm and a length of 10 cm. Approximately 2 g of powder were placed in the columns for measurement. Due to the poor handling properties of the kaolinite and metakaolin powders, compaction, crushing and sieving was carried out beforehand. This procedure ensured a suitable gas flow rate in the IGC column. To do this, kaolinite and metakaolin samples were compacted in a pelletizing mold under a pressure of 1 ton for 2 minutes. Afterwards, the pellets were crushed and sieved. A 3.2 mm (1/8 in.) measuring column, with an internal diameter of 2 mm and a length of 10 cm, was filled with pieces with a size between 250 to 450 m. Approximately 0.35 grams of kaolinite and metakaolinite were used in each case. Before conducting the measurements, the surface of the samples inside the column was conditioned for the tests using a flow of dry helium at 5 mL/min during 16 h at 30°C. Measurements were conducted at 30°C for all samples, except kaolinite. In this case, the retention times observed were extremely long, and the measurement temperature was increased to 80°C on this sample to achieve full elution over a reasonable timeframe. Hexane, heptane, octane, nonane, isooctane, 2,2-dimethyl-hexane (2,2-DHM) and cyclooctane were used as n-alkane probes to determine the dispersive surface energy. Isooctane, 2,2-dimethyl-hexane (2,2-DMH) and cyclooctane were used as branched and cyclic probes to measure the surface nanoroughness. Acetone, acetonitrile (CH3CN), tetrahydrofuran (THF), ether, chloroform (CHCl3) and benzene were also used as polar probes to determine the acid-base character of the different cementitious materials. For IGC-FD measurements, water and isopropanol were used as probes over the set of samples with helium as carrier gas in both cases. Water was initially used over C3A and C3S-I samples. In this case, P/P0 values from 0.15 to 0.64 were explored. A strong interaction of water with the surfaces was observed, and consequently isopropanol was selected as a more suitable adsorbate to conduct further experiments. Measurements with isopropanol were done for C3A, C3S-I, C3S-II, C3S-II Ann, C3S-II-TEA, Kaolinite, MK and MK-TEA. For these measurements, the injected amount of isopropanol was fixed so to achieve a P/P0 up to 0.2, with a minimum of 3 injections. All isopropanol injections were preceded by injection pulse of methane (CH4), used as a reference to compute the retention times (TR) at each point of the chromatogram. All measurements were conducted at 30°C. For all cement phases, a 6.4 mm (1/4 in.) measuring column, with an internal diameter of 4 mm and a length of 10 cm was used. The columns were filled with 1.6-2 g of sample. In the case of C3S-II Annealed, a shorter column (3 cm, filled with 0.6 g of sample) with the same diameter was used to decrease the observed retention time. In the case of clay minerals, a 3.2 mm (1/8 in.) measuring column, with an internal diameter of 2 mm and a length of 5 cm was used, filled with 0.13 to 0.18 g of sample. The clay powders were pelletized in the same way as for the IGC-ID measurements. Isothermal calorimetry was used to characterize the reactivity of the different cement phases. Paste samples were prepared by mixing 15 g of powder with distilled water at a water-to-solids ratio of 0.35. A high shear mixer was used at 1600 rpm for 2 minutes. Afterwards, 10 grams of sample were placed in a glass ampoule and sealed. A TAM Air isothermal calorimeter was used to monitor the heat release of the samples for 7 days at 20°C. Isothermal calorimetry was also used to assess the reactivity of the different clay minerals. For this purpose, the R3 test (ASTM C1897) [16] was selected due to its reliability and ease of interpretation. In this procedure, the different clays are mixed with portlandite, calcium carbonate, potassium sulphate, potassium hydroxide and water at 40 °C, and put into glass ampoules inside the calorimeter at 40 °C. The total heat evolved is taken as a measure of the reactivity of the clays., This paper presents a preliminary study of the characterization of the surface energy properties of clinker phases (C3S and C3A), kaolin and metakaolin by Inverse Gas Chromatography (IGC). For this, a reliable measurement methodology was developed. By looking at changes in the whole series of results (dispersive surface energy, specific polar interaction parameter, acid and base constants, morphology index, nanoroughness and adsorption energy distribution function), it is possible to discern changes between the same powders with different surface treatments. A promising correlation between surface properties and the reactivity of studied materials have been found. However, based on the IGC characterization, the increased reactivity of metakaolin compared to the raw kaolinite seems to be strongly linked to the change in local order rather than significant changes in the surface energetics, although a change in the acid/base nature of the surface has been observed., Swiss Agency of Development and Cooperation (SDC) grant 81026665; Swiss National Science Foundation (SNSF) through an Ambizione fellowship (grant 208719); Consejería de Educación e Investigación (Comunidad de Madrid) which funded the 2016-T1/AMB-1434 project in the frame of “Ayudas de Atracción de Talento Investigador”; Ministry of Science and Innovation through funding PID2020-115797RB-I00/AEI/10.13039/501100011033 project., File List: DRX C3S; PSD_C3SC3A; Calculation KaKb; Data_DI&FC; Data_IGC-FC; Water_AEDF_norm; Water_AEDF, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Rheological Behavior of Oil Well Cement Slurries with Addition of Core/Shell TiO2@SiO2 Nanoparticles—Effect of Superplasticizer and Temperature [Dataset]

  • Batista, Giovanni dos Santos
  • Puertas, Francisca
  • Shigueaki Takimi, Antonio
  • Costa, Eleani Maria da
  • Palacios, Marta
This study investigates the rheological behavior of oil well cement pastes (OWCPs) modified with core/shell TiO2@SiO2 (nTS) nanoparticles and polycarboxylate-ether (PCE) superplasticizers at different temperatures (25, 45, and 60 °C). Results show that nTS particles increased static and dynamic yield stresses and the apparent viscosity of the cement slurries due to an increased solid volume fraction and reduced free water availability. The increase in the slurry dispersion by adding PCE superplasticizers enhanced the effect of the nanoparticles on the rheological parameters. Oscillation rheometry demonstrated that nTS nanoparticles enhanced the structural buildup, while PCE retarded hydration. Furthermore, slurries hydrated at 60 °C experienced higher initial values of the elastic modulus and a faster exponential increase in this rheological parameter due to the acceleration of the cement hydration., This research was partly funded by Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES), grant number 001 and PID2020-115797RB-I00/AEI/10.13039/501100011033 (RHEODUR) project., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Evolution of the microstructure of limestone-calcined clay cement pastes exposed to CO2 [Dataset]

  • Pachón Montaño, Alicia
  • González-Panicello, Laura
  • Alonso, M. Cruz
  • Puertas, Francisca
  • Roig-Flores, M.
  • Palacios, Marta
The carbonation and microstructural changes in the pastes were monitored over 1 year (at 1, 30, 90, 180 and 365 days). The evolution of the pore structure of the different cement pastes was characterized by mercury intrusion porosimetry (MIP) with an AutoPore IV 9510 from Micromeritics. The maximum mercury intrusion pressure was set at 60.000 psi, corresponding to a minimum pore diameter of 4 nm. The mercury surface tension and the contact angle between the mercury and the solid surface were 0.484 N/m and 141°, respectively. Previous to this analysis, the samples of 1 x 1 x 2 cm3 were placed in 200 ml of isopropanol over 7 days. Afterwards, the samples were dried in a low vacuum desiccator up to constant weight. The evolution of the mineralogy and microstructure of the non-carbonated and carbonated pastes was also monitored by thermogravimetry (TGA), quantitative X-ray diffraction (QXRD), Fourier Transform infrared spectroscopy (FTIR) and Nuclear Magnetic Resonance (NMR) techniques. Previous to this analysis, pastes were ground by hand mortar and the hydration was stopped by mixing with isopropanol during 1 min in a solid:isopropanol ratio of 1:10 [30],[31]. Thermogravimetry (TGA) was used to determine the amount of bound water, calcium hydroxide and calcium carbonate of the different pastes from the weight loss due their composition on heating. TGA experiments were conducted using a TGA-DSC-DTA Q600 instrument (TA Instruments). Approximately 30 mg of sample in a platinum crucible was heated from 25 °C to 1000 °C at a rate of 10 °C/min under a flow of N2 at 100 mL/min. Crystalline phases were analysed by X-ray diffraction (XRD) using a D8 ADVANCE diffractometer (BRUKER-AXS, Billerica, MA, USA) in a θ-2θ configuration with Cu-Kα1 and Cu-Kα2 radiation (1.5406 Å and 1.5444 Å). The samples were scanned between 5° and 70°, with a step size of 0.01973° and using an ultra-fast RX “Lynxeye” detector, which includes a 3 mm anti-scatter slit, a 2.5° Soller second slit, and a Ni K-beta filter (0.5%). Crystalline phases were identified using DIFFRACT.EVA V4.2.1 software in conjunction with the Crystallography Open Database (COD) and crystalline and amorphous phases were quantified using the Rietveld method with Topas 5 software from Bruker. Amorphous content was determined using the internal standard method and 20%wt of corundum (Al₂O₃ was added to each sample). The corundum was prepared from 99.9%wt purity α-phase Al₂O₃ (Thermo Scientific) and subjected to a thermal treatment, at a heating rate of 13 °C/min up to 1600 °C, held at 1600 °C for one hour, and then allowed to cool naturally to room temperature inside the furnace., Fourier-transform infrared (FTIR) spectra acquired using a Nicolet 6700 spectrometer (Thermo Scientific, Madison, USA). KBr pellets were prepared by mixing 1 mg of the sample with 200 mg of KBr. The spectra were recorded over a frequency range of 4000 to 400 cm⁻¹, with a resolution of 4 cm⁻¹. These spectra allow to identify band shifts in the silicate region, which could indicate modifications in the polymerisation of the C-S-H/C-A-S-H. This technique provided also additional information about the polymorphism of the CaCO3 formed. Carbonated and non-carbonated pastes were also analyzed using 29Si and 27Al MAS NMR. A Bruker AVANCE-400 spectrometer operating at a 9.4 T magnetic field was used. A 4 mm (outer diameter) ZrO₂ rotor was employed, spinning at a frequency of 10 kHz. 29Si MAS NMR spectra were recorded at a resonance frequency of 79.49 MHz, with a pulse length of 5 μs, a recycle delay of 10 s, and 6000 scans for each measurement. 27Al MAS NMR spectra were recorded at a resonance frequency of 104.26 MHz, with a pulse length of 2 μs, a recycle delay of 5 s, and 720 scans for each measurement., After the 28 days of curing and prior to start the carbonation process, all the samples were preconditioned in controlled environment chamber at 23 oC and a relative humidity of 70% ± 2% RH, achieved using saturated potassium iodide (KI) solutions. To keep the interior of the chamber free of CO2, soda lime was placed inside. After the two-week period, half of the samples were placed in an environment controlled chamber with 1%wt CO2, a relative humidity of 70% ± 2% RH and 23 oC. Additionally, the other half of the samples were kept in a separate chamber at a RH= 70% ± 2% and 23 oC to study the evolution of hydration over time. Soda lime was placed in this chamber to ensure the non-carbonation of these samples. The monitorization of the microstructure and hydration of these samples in a free-CO2 atmosphere will allow to better identify the changes induced in carbonated samples attributed to hydration or carbonation., No