Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Supplementary information about The PIONEER database

  • Salden, Antoine
  • Budde, Maik
  • García Soto, Carolina A.
  • Biondo, Omar
  • Barauna, Jairo
  • Faedda, Marzia
  • Musig, Beatrice
  • Guaitella, Olivier
Data processing: Computed columns: By parsing the input data it is possible to increase the amount of columns in the database without changing the source format. The following columns are computed (or updated) in the back-end when the database is loaded from disk to memory.-- Assumptions for calculations: A number of parameters are (re)calculated based on provided metadata for publications: the residence time (1), the SEI in J L-1 (2), energy efficiency of CO2 conv. % (5) but also the frequency range column (section 8.1). Each of these calculations rely on data that potentially is given as a range of values, see section 1. By convention, the mean of the range is taken for each of the parameters. All entries for which a (re)calculation has been performed on either the x or y data, have the Calculated field set to ‘Calculated’ (rather than ‘Original’). Filtering the database on only Original data, this calculated data can be replaced with calculations by the user based on other aggregation, if desired. As mentioned for equation (2), the calculation that converts power (in W) to SEI (J L-1) simply relies on the gas flow rate Φ (in sccm or mLmin-1) and therefore does not take into account if Φ is defined w.r.t. standard conditions or the actual conditions in the discharge regarding pressure and temperature. Since generally in this case both the power and gas flux are know, the SEI can be calculated (except for batch reactors where there is no flow), which allows for a comparison between a larger body of experiments. Contrary to this, the calculations for the residence time (1) and energy efficiency of CO2 conversion both take into account the discharge conditions. This discrepancy is a conscious one: the SEI (in J L-1) is often reported as a macroscopic process parameter that is calculated from the power and fluxes put into the reactor. For τ res taking into account the conditions inside the plasma is paramount, since it can provide the information on how long a particle is exposed to plasma conditions. Do note that in lieu of the plasma –or active zone– volume, for some experiments an approximation such as the reactor volume is used, see column relevant volume in section 4. Likewise for the efficiency, it is important to account for the actual measurement conditions to establish the number of particles into which energy has been channelled. For in situ versus effluent conditions this can be very different. Overestimating the number density favourably improves efficiency, whilst an underestimation similarly negatively impacts it. While the way in which the PDB is structured and reports metadata is not without caveats (section 4.3 of the paper), the distinction between in- versus post-plasma dissociation measurements can be partially addressed by tailored filtering and aggregation of the data contained within.-- Normalisations: Several normalisation functions are available in the interface of the database. As described in the main text, the aim to provide a tool for easy calculation of normalised data within the same interface and compare with different data sets. For flexibility sake, a wide set of normalisations are provided, without restriction on whether they are sensible in a given context. The purpose of each normalised function is described briefly and summarised in table 1 along with the equations utilised.-- Under a Creative Commons license CC BY 4.0., The Pioneer database (PDB) is divided into two parts: performance data and metadata. The performance data originate from measurements reported in literature, where they are typically provided in form of plots or tables. The PDB and its dedicated online tool allow to compare large amounts of performance data to derive trends leading eventually to process optimisation. Performance data is provided in form of plain text files with only two comma-separated columns of numbers with a point (.) as decimal separator, without a header (as it is inferred from the metadata). The first column contains what is henceforth called process parameters. These are the independent variables of the experiments, i.e. the x-values like power, pressure etc., see section 7. The second column contains the so-called performance parameters. These are the dependent variables of the experiment, i.e. the y-values like conversion, selectivity etc., see section 7. The metadata contain additional information about the measurements that are crucial for their interpretation. Metadata are provided in table format following the template discussed subsequently. Before elaborating on the actual data input, the structure of the PDB metadata is discussed. The metadata is grouped thematically in categories. Within each category, information is entered into fields, i.e. the columns of the table. Essential and conditional fields are distinguished. Essential fields contain crucial information for the assessment of the plasma-catalytic process. In the best case scenario, all of them are given in the respective publication. When fields are listed in the description of a category from section 2 onward, essential fields are indicated by a regular bullet point (•). Conditional fields are by no means less important than essential ones, but can rather be left empty depending on other fields. For instance, most fields in the catalyst category are left empty, when no catalyst is used. Thus, conditional fields are meant to save time. Listed in the following, they are indicated by a plus (+). In conclusion, all fields are strongly recommended as data useful for valuable comparison with other work from the community. A subgroup of essential as well as conditional fields are those fields that contain the process parameters defined in the first paragraph of this section. Generally speaking, process parameters are the experimental settings in the pursuit of highest performance. The user of the PDB thus encounters process parameters on two occasions: on the one hand as typical x-values in the performance data and on the other hand as input to fields of the metadata. Hereafter, fields that contain process parameters and parameters are used synonymously. The total of fields belonging to the same measurement make up what is hereafter called a data set, corresponding to a row of the table. Note that here the input of data is addressed. In the back end, a data set is broken up into (x,y)-pairs for more flexibility in data handling. Data is exported also in that format. To ensure comparability, a template is used for inputting information into the PDB metadata. With respect to information entered, fields can be divided in numerical and textual fields. They are filled with numbers or text, respectively. For example, parameters are usually numerical fields. A numerical field contains either (i) one number x if the numerical value is known and does not change during the experiment; (ii) a range of values between xmin and xmax –given as array-like notation rxmin; xmaxs– if the numerical value is not exactly known, or when it changes in the course of the measurement; or (iii) NA if the numerical value is not known. For further use, an aggregate function is applied to array-like data to obtain a single number, by convention the mean. A textual field contains a string of text. There are a few instances where text can be entered freely as long as some format is followed. However, usually the field is filled by selecting from a pre-defined list of options in the template. Most of these lists are fixed but some might be extended in the future depending on the experimental data provided. This paragraph just gives a general overview. In the in-depth discussion of the fields of each category, it gets more clear what exactly is supposed to be filled in each field. The metadata of the PDB are divided into six categories • data identification • gas mixture • plasma source • catalyst • separation unit • output data, 1. General 2. Data Identification 3. Gas Mixture 4. Plasma Source 5. Catalyst 5.1 Catalyst Coupling . 5.2 Catalyst Composition 5.3 Catalyst Pre-treatment Before Reaction 5.4 Catalyst Conditions 5.5 Catalyst Characterization 6. Separation Unit 7. Output Data 8. Data processing 8.1 Computed columns 8.2 Assumptions for calculations 8.3 Normalisations, When data is reported according to the specified scheme above, the combined data and metadata can be read from disk and processed with some scripting. Most notably this performs data type coercion and extraction from a more flexible ‘human-readable’ format to a consistent, ‘machine-usable’ scheme. Some of the computed columns are redundant to some extent –the authyear column for instance is just a concatenation of the first author name and publication year (yyyy) columns– but these are provided for ease of filtering or grouping data, avoiding frequent (re)computation., This project has received funding from the European Unions Horizon 2020 research and innovation programme under the Marie Skodowska-Curie grant agreement No. 813393, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Appendix A. Supplementary data for Nanostructured CeO2 as support of Ni-catalysts for plasma-catalytic CO2 methanation: Tailoring support’s nanomorphology towards improved performance [Dataset]

  • Musig, Beatrice
  • Roy, Abhijit
  • Arenal, Raúl
  • García Martínez, Tomás
  • Gálvez Parruca, María Elena
  • Navarro López, María Victoria
The textural features of the CeO2 supports and calcined catalysts were assessed by means of N2 adsorption at -196 °C, performed in an Autosorb 6 device (Quantachrome). X-Ray diffraction patterns (XRD) were acquired in a Bruker D8 Advance series II diffractometer using monochromatic Cu-Kα radiation (λ = 0,1541 nm) operated at 40 kV and 40 mA. Data were collected in the 2θ range from 20° to 90°, using a step size of 0.02° and a step time of 3 s. All the patterns obtained were calibrated against a silicon standard. The identification of crystalline phases and the subsequent Rietveld analysis was performed using the TOPAS software. Raman spectra were acquired in a Horiba Jobin Yvon HR800 UV dispersive laser Raman microscope. X-ray photoelectron spectroscopy (XPS) measurements were used to investigate the surface composition and chemical states of cerium and nickel. They were performed in a ESCA+ (Omicron) photoelectron spectrometer using a non-monochromatic AlKalpha X-ray source (h = 1486.7 eV). A pass energy of 50 eV was used for survey scans and 20 eV for detailed scans. Binding energies were referenced to the Ce3d v’2 (917 eV). The obtained spectra were analyzed using the CasaXPS software. Oxygen Storage Capacity (OSC) measurements of the nanostructured CeO2 supports were performed by thermogravimetric analysis (TGA) in a SETARAM Setsys Evolution device. Inductively coupled plasma atomic emission spectrometry (ICP-AES) was performed on the reduced catalysts using a Xpectroblue-EOP-TI FMT26 (Spectro) spectrophotometer and pre-treating the samples with lithium tetraborate. To assess the reducibility of the materials temperature-programmed reduction in H2 (H2-TPR) measurements were conducted in a BELCAT-M apparatus (BEL Japan Inc.) equipped with a thermal conductivity detector (TCD). Details on the morphology of the CeO2 nanostructured supports, as well as on the Ni-phase distribution on the catalysts prepared, were gained through scanning (SEM) and transition (TEM) electron microscopy analyses. SEM micrographs were acquired using a SEM Hitachi S-3400N microscope with variable pressure couple to an energy-dispersive X-ray spectrometer (X-EDS) Röntec XFlash operated at 10 kV. High-resolution TEM (HRTEM) was performed in a FEI Titan microscope at 300 kV containing spherical-aberration corrector at the objective lens. The high-resolution scanning TEM (HRSTEM), high-angle annular dark-field STEM (HAADF-STEM) images were acquired by a FEI TITAN Low Base TEM at 300 kV containing aberration corrector at the condenser lens and also equipped with X-EDS detector.-- Under a Creative Commons license CC.BY-NC-ND/4.0., 1. Synthesis of the CeO2 supports. 2. Physicochemical characterization techniques and devices. 3. Plasma-catalytic and thermo-catalytic setups & experimental procedures. 4. SEM and TEM characterization: 4.1. CeO2 supports. 4.2. Reduced Ni-catalysts. 4.3. Spent Ni-catalysts (used in plasma-catalytic methanation). 5. X-ray diffraction. 6. N2-adsorption isotherms. 7. X-ray photoelectron spectrometry. 8. Raman spectroscopy. 9. 10 h time-on-stream methanation experiments, This work received funding from the European Union’s Horizon H2020 research and innovation programme under the Marie Skłodowska-Curie [grant number 813393]. This work was supported by the Departamento de Ciencia, Universidad y Sociedad del Conocimiento of the Gobierno de Aragón [project number LMP151_21]., Peer reviewed