Pasar al contenido principal

EL HIERRO COMO COMBUSTIBLE EN NUEVOS CICLOS DE ALMACENAMIENTO DE ENERGIA

PID2022-141372OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Supporting Information for Apparent kinetics for direct oxidation of iron particles determined from tests at high temperature in a flat flame reactor [Dataset]

  • Jiménez, Santiago
  • Mayoral Gastón, María del Carmen
  • Romeo, Luis M.
Under a Creative Commons BY 4.0 license., Figure SI1. Post-tests picture of a 75 μm platinum wire (straight, smooth) and a fragment of a ~112 μm iron oxide wire (originally 50 μm, pure iron); Figure SI2. General aspect of the iron ‘flames’. From left to right, 0.5, 4.1, 8, 12, 16% O2. Time exposure 1/100 s. The tube length is 49 cm. The gas flat flame is hardly visible at top; Figure SI3. X-ray diffractograms (black line) and Rietveld quantitative fit in samples collected at different heights below the burner (indicated below the legend). Note that FeO is represented by several compounds. (Continues); Figure SI3 (Continued). X-ray diffractograms (black line) and Rietveld quantitative fit in samples collected at different heights below the burner (indicated below the legend). Note that FeO is represented by several compounds. (Continues); Figure SI3 (Continued). X-ray diffractograms (black line) and Rietveld quantitative fit in samples collected at different heights below the burner (indicated below the legend); Figure SI4. Evolution of the particle size distribution (number-weighed) for the 63-75 μm cut in 4.1, 8 and 16% O2. Legend shows HbB in cm.; Figure SI5. Fraction of iron in the samples determined by TGA vs. XRD for the two size cuts studied in the present work and in a recent study with 75-90 μm particles. Figure SI6. Size distributions of the iron 63-75 μm particles. Blue, continuous: original fuel, laser diffractometer, volume-weighed (D43~90 μm); blue, short-dashed: idem, but number-weighed (D10~74 μm); red, long-dashed: number-weighed distribution in the sample with smallest oxidation degree but round aspect (D10~72 μm); Figure SI7. Photographs in a microscope (x40) of the original 63-75 μm particles (top), and samples collected at 19 cm, 4.1% O2 (center) and 12 cm, 8% O2 (bottom)., This work was partly funded through grant PID2022-141372OB-I00 by MICIU/AEI/10.13039/501100011033 and by ERDF/EU., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Supplementary data for Quantification of iron vaporization and fragmentation during direct oxidation in moderate oxygen concentrations

  • Jiménez, Santiago
  • Mayoral Gastón, María del Carmen
Under a Creative Commons BY 4.0 license., Table SM1. Cut diameters of the impactor stages, under the assumption of isolated spheres, for densities 1000 kg/m3 (“aero”) and 5300 kg/m3 (“Fe2O3”). -- Figure SM1. Particle size distributions of the coarse particle mode (i.e. those collected in the cap in Fig. 2), together with the original 63-75 μm iron particles, as measured in a laser diffractometer.-- SM2_DSC_0663_rot.AVI Video with a pair of (intended) interruptions in the fuel feeding.-- SM3. As in Figure 3 in the paper (16% O2, i.e. first in the right) but with 1/500 s exposure, so that the micro-clouds can be distinguished more clearly.-- Figure SM4. X-ray diffractogram of the sample collected on stage #6 (peak of the submicronic mode) in the test with 16% O2 (black line) and automatic fit by the Rietveld method (red line).-- Figure SM5. X-ray diffractogram of the sample collected on stage #4 (peak of the submicronic mode) in the test with 6% O2 (black line) and automatic fit by the Rietveld method (red line)., This work was partly funded through grant PID2022-141372OB-I00 by MICIU/AEI/10.13039/501100011033 and by ERDF/EU., Peer reviewed