CARGADORES DE BATERIAS BIDIRECCIONALES PARA LA INTEGRACION EN MICRORREDES DE VEHICULOS ELECTRICOS Y ESTACIONES DE CARGA ULTRARRAPIDA CON BATERIAS DE RESPALDO

RTI2018-100732-B-C21

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Datos de investigación Set de datos (Dataset)

Experiment 5 REMOTEWEAK Control Scheme Surpress Circulating Currents Parallel 3Phase Inverters [Dataset]

  • Liberos, Marian|||0000-0001-6574-1158
  • González-Medina, Raúl|||0000-0003-0378-5045
  • Patrao Herrero, Iván|||0000-0003-4412-0365
  • Garcerá, Gabriel|||0000-0002-5507-4379
  • Figueres Amorós, Emilio|||0000-0002-0716-3916
This dataset is about the experimental results obtained and published in the article "A Control Scheme to Suppress Circulating Currents in Parallel-Connected Three-Phase Inverters": Liberos, M.; Gonzalez-Medina, R.; Patrao, I.; Garcera , G.; Figueres, E. Electronics 2022, 11, 3720. DOI: 10.3390/electronics11223720 The parallel operation of inverters has many benefits, such as modularity and redundancy. However, the parallel connection of inverters produces circulating currents that may result in malfunctions of the system. In this work, a control technique for the elimination of the low-frequency components of the circulating currents in grid-connected inverters is presented. The proposed control structure contains n - 1 zero-sequence control loops, with n being the number of inverters connected in parallel. Simulation and experimental results have been carried out on a prototype composed of two 5 kW inverters connected in parallel. The results have been obtained by considering the following mismatches between both inverters: inductance values of the grid filters, unbalance of the delivered power, and the use of different modulation techniques.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Datos de investigación Set de datos (Dataset)

Experiment 6 REMOTEWEAK Experimental Study of the Parameter Mismatch Effects on the Low Frequency Circulating Currents of Parallel Three Phase Inverters [Dataset]

  • Liberos, Marian|||0000-0001-6574-1158
  • González-Medina, Raúl|||0000-0003-0378-5045
  • Patrao Herrero, Iván|||0000-0003-4412-0365
  • Torán, Enric|||0000-0002-0868-9856
  • Garcerá, Gabriel|||0000-0002-5507-4379
  • Figueres Amorós, Emilio|||0000-0002-0716-3916
This dataset is about the experimental results obtained and published in the article "Experimental Study of the Parameter Mismatch Effects on the Low Frequency Circulating Currents of Parallel Three Phase Inverters":Liberos, M.; González-Medina, R.; Patrao, I.; Torán, E.; Garcerá, G.; Figueres, E. Eng 2023, 4, 1356-1376. DOI: 10.3390/eng4020079 When converters are connected in parallel, a system with some benefits, including modularity and redundancy, is obtained. However, in these circumstances, circulating currents can appear that produce some adverse effects. In this work, a study of the low-frequency circulating currents that appear in three-phase inverters connected in parallel is performed. The study is focused on the effects produced by the parameter mismatch, namely inductance mismatches, power imbalance, and the use of different pulse with modulation (PWM) techniques. The nature of the circulating current produced by each of these factors were analyzed separately. Both simulation and experimental results are shown, which were obtained using a three-phase 10-kW prototype composed of two 5-kW inverters connected in parallel
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Datos de investigación Set de datos (Dataset)

Experiment 9 REMOTEWEAK: Comparative Analysis B4 and B6 Grid Connected Inverters [Dataset]

  • Torán, Enric|||0000-0002-0868-9856
  • Liberos, Marian|||0000-0001-6574-1158
  • Patrao Herrero, Iván|||0000-0003-4412-0365
  • González-Medina, Raúl|||0000-0003-0378-5045
  • Garcerá, Gabriel|||0000-0002-5507-4379
  • Figueres Amorós, Emilio|||0000-0002-0716-3916
A theoretical analysis of a three-phase grid-connected B4 photovoltaic inverter was carried out, including modeling, control design, and stability assessment of the current and voltage control loops. The influence of photovoltaic voltage and grid inductance variations was analyzed through a parametric stability study. Finally, simulation-based evaluations were performed under ideal and distorted grid conditions to assess harmonic behavior, DC bus voltage ripple, and overall system performance., Funded by the Ministerio de Ciencia e Innovacion of Spain and the European Regional Development Fund (ERDF) under Grant RTI2018-100732-B-C21-AR. Funded by the Ministerio de Ciencia e Innovacion of Spain and the European Regional Development Fund (ERDF) under Grant PID2021-122835OB-C22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Datos de investigación Set de datos (Dataset)

Experiment 2 REMOTEWEAK Control Parallel Interlinking Inverters Hybrid ACDC Microgrid [Dataset]

  • Liberos, Marian|||0000-0001-6574-1158
  • González-Medina, Raúl|||0000-0003-0378-5045
  • Patrao Herrero, Iván|||0000-0003-4412-0365
  • Torán, Enric|||0000-0002-0868-9856
  • Garcerá, Gabriel|||0000-0002-5507-4379
  • Figueres Amorós, Emilio|||0000-0002-0716-3916
Having two or more interlinking converters connected in parallel in hybrid microgrids with AC and DC buses has some benefits, like modularity, flexibility, and redundancy. However, the parallelization of the inverters leads to circulating currents that can cause system malfunctions. This work uses a method for suppressing low-frequency circulating currents in interlinking converters by controlling the zero-sequence component of the phase currents, showing that the control structure is valid for interlinking converters. The proposed control scheme has been applied to two parallel interlinking inverters of 5 kW and 2.5 kW, respectively. The interlinking inverters are connected to the grid, and they control the voltage in the DC bus of the hybrid microgrid. To validate the concept, simulation and experimental results are shown.